Loading...
HomeMy WebLinkAboutProduct Approval I Florida Building Code Online Page 1 of 2 WN S) t I 5 ' •� qq ..� pt a ' BQS Home i Log In ' User Registration Hot Topics Submit Surcharge - Stats&Facts Publications FBC S[aff ! BCIS Site Map Links Search I P EA-, r }Product Approval USER:Public Use., I I I ' I; 1 Product Approval Menu>Product or ADDlication Search>Application List>Application Detail I I fi- - �I I ' FL FL2569-R12 Application Type Revision Code Version 2014 Application Status Approved I I' Comments r Archived i ' I Product Manufacturer Soprema,Inc. (Canada) I, Address/Phone/Email 1640 rue Haggarty Drummondville, NON-US 00000 (819)478-2400 I I' memathieu@soprema.ca Authorized Signature Marc-Etienne Mathieu memathieu@soprema.ca I j Technical Representative Marc-Etienne Mathieu Address/Phone/Email 1688 Jean-Berchmans-Plicli1aud I ' Drummondville,NON-US 00000 I' (819)478-2400 Ext 3327 I I memathieu@soprema.ca I' I l ii II Quality Assurance Representative Jean-Francois Cote, Ph.D. Address/Phone/Email 1640 rue Haggarty (, Drummondville ; (888)811-3145 I fj fcote@soprema. Category Roofing li ! I I� Subcategory Underlayments i i Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received { Florida Engineer or Architect Name who developed Robert J. M. Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC 1 Quality Assurance Contract Expiration Date 07/17/2020 i l Validated By John W.I Knezevich,PE I ' Validation Checklist-Hardcopy Received 1 I', Certificate of Independence FL2569 R12 COI 2017 D1 COI Nieminen.odf Referenced Standard and Year(of Standard) Standard Year j ASTM D1970 I' I 2009 ASTM D6163 I' 2000 ASTM D6164 2005 FM 4474 2004 FRSA/TRI April 2012(04-12) I 2012 TAS 103 ii I' 1995 TAS 110 2000 UL 1897 i I' 2004 ' I Ir http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQ IwtDgsIl QFEnckB 10... 11/1/2017 j I ' I I ' _ Equivalence of Product Standards ,I ; Certified By Sections from the Code , I ii i j A I Product Approval Method Method 1 Option D I'. Date Submitted 06/12/2017 ' Date Validated 06/13/2017 I Date Pending FBC Approval 06/15/2017 Date Approved 08/08/2017 i Date Revised 10/09/2017 1 I Summary of Products I FL# Model,Number or Description Name I'I 2569.1 Soprema Roof Self adhering roof underlayments Underlayments i Limits of Use Installation Instructions Approved for use in HVHZ:No FL2569 R12 II 2017 06 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569- Approved for use outside HVHZ:Yes R12.Ddf Impact Resistant:N/A Verified By:Robert Nieminen, P.E. PEI-59166 i Design Pressure: +N/A/-150 Created by Independent Third Party Yes Other: 1.)Refer to ER Section 5 for Evaluation Reports Limits of Use.2.)The design pressure X2569 R12 AE 2017 06 FINAL E_R SOPREMA CA UNDERLAYMERTS FL2569- noted herein pertains to underlayment R12.Ddf I� ! systems used beneath adhesive-set tile Created by Independent Third Party:Yes systems.Refer to ER Section 5.6.4 for !' details. ' I Back Next fl i I{ Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phorie:850-487=1.624 The State of Florida Is an AAJEEO employer.Copyright 2007-2013 State of Florida.::Privacy Stat ent::Aeeeeisibility Statement::Refund Statement I II 11 Under Florida law,email addresses are public records.IF you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have ady questions,,please contact 850.487.1395."Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees.licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.Hovrevefjemail addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click hem. I Product Approval Accepts: I�' tom''' SrrV l; Credit Card I Safe !;; I Ii f � I I http://www.floridabuilding.org/pr/pr_app_dtl.aspx?paraln=1AGEVXQwItDc{sK! FEn;chB10.... 11/1/2017 it !� lit Page 2 of 2 Florida Building Code Online I � Y! I I' i' i Y S•. I •ii t 'I I ' t 1 � Y I I I ,j EI I i t Y i i i I• 1 t iI Y 1 • I F I i i I Y i 7� 1' t i; ' 1 I ' I i j, .I EiXTERIO!R RESEARCH&DESIGN,LLC. 'Certificate of Authorization#9503 �- 353 CHRISTIAN STREET,UNIT#13 ���RINITY, I OXFORD,CT 06478 i (203)262-9245 I EVALUATION REPORT j Soprema,Inc. ;Evaluation Report 518010.06.09-R10 1640 rue Haggerty I FL2569-R12 Drummondville,Qu6bec J2C 5P8 Canada Date of Issuance:06/15/2009 (819)47872400 j Revision 10:06/12/2017 it SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has,been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Bull ing Code, Residential Volume. The products ,described herein have been evaluated for compliance with the 5t Edition {2014) 'Florida Building Code sections noted herein. DESCRIPTION: Soprema Roof Underlayments l LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. I; I I CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named prodju'ct(s) changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of ithis Evaluation Report by the named client constitutes agreement to notify Robert Plieminen, P.E. if the product changes or the'referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Frinityl ERD Evaluated" may be displayed in r advertising literature. if any portion of the Evaluation Report is displayed,then itjshall be done in its entirety. INSPECTION: Upon request,a co II 1'' p q copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request f the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: �! r Robert J.M. N Iem i nen,P.E. The facsimile seal appearing was authorized by RobertN ieminen, i T•. ro Florida Registration No.59166,Florida DCA ANE1983 ""' _ P.E.on 06/12/2017.This does not serve as an electronically signed r�.'�� �trf�f1`l.�G;.`''` dociument.Signe,sealed hardcopies have been transmitted to the - Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest lin any company manufacturing or distributing products it evaluates. 2. Trinity)ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which•the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. j 1 5. This is a building code evaluation. Neither Trinity lERD nor Robert Nieminen, P.E. are,lin any way,the Designer of Record for any f project on which this Evaluation Report,or previous versions thereof,is/was used for pelrmitting!or design guidance unless retained specifically for that purpose. I f ,I TRINFTY�ERD ROOFING COMPONENT EVALUATION: r II i 1. SCOPE: Product Category: Roofing I II Sub-Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard i �r Year 1504.3.1 Wind Resistance FM 4474 ! 2004 1504.3.1 Wind Uplift UL 1897 i 2004 1507.2.4,1507.2.8,, Physical Properties ASTM D1970 I, 2009 1507.2.9.2,1507.4.5.1, 1507.5.3,1507.7.3 1507.11.2 Physical Properties ASTM D6163 I'' 2000 1507.11.2 Physical Properties ASTM D6164 j 1 I 2005 1523.6.5.2.1 Physical Properties TAS 103 i 1995 TAS 110 Accelerated Weathering TAS 110 2000 1507.3.3 Installation Practice FRSA/TRI April 2012,i'04-12)1 2012 3. REFERENCES: I � I Entity Examination Reference Il. i Date j ERD(TST6049) ASTM D1970/TAS 110 2968.05.042 i, ;I 05/14/2004 ! ERD(TST6049) Physical Properties 2757.02.05' i, 02/03/2005 ERD(TST6049) ASTM D1970/TAS 110 2974.03.051,-2 I 05/17/2005 ERD(TST6049) Wind Resistance 2778.07.051 07/15/2005 ERD(TST6049) Wind Resistance 2779.11.05''-R1 I i, 04/18/2007 ERD(TST6049) TAS 103/TAS 110 S7120.11.07-2 I' 11/02/2007 i ! ERD(TST6049) ASTM D1970/TAS 110 S13190.026-111 j i 04/01/2010 i ERD(TST6049) ASTM D1970/TAS 110 S31370.031110-1-R1 j I, 04/07/2010 ERD(TST6049) Physical Properties/Tensile Adhesion S11_150.05.,'10-111 I;! 09/09/2010 ERD(TST6049) Physical Properties/Tensile Adhesion S11150.05109-R2 10/05/2010 ERD(TST6049) ASTM D1970 S37210.11.111 I' 11/09/2011 I ERD(TST6049) ASTM D1970 540540.021113-1 I:3 1 02/19/2013 1 ERD(TST6049) Physical Properties/Tensile Adhesion S43530.021.114-1 I•' 02/21/2014 i ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC761�5.02.15� 02/13/2015 ERD(TST6049) Accelerated Weathering SOPC-SC8520.14 L, 04/17/2015 ERD(TST6049) Wind Resistance SOPC-SC14045.05.1:7-R1 06/07/2017 M-D(CER1592) HVHZ Compliance 15-0508.04 09/24/2015 i ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 I'I 03/01J2017 i PRI(TST5878) Physical Properties SOP-064-02-0112/03/2013 j Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 4011 05/29/2015 UL,LLC(QUA9625) Quality Control Service Colri'firmatign Exp.10/16/2017 • I 4. PRODUCT DESCRIPTION: ! 4.1 Lastobond TU HT is a self-adhering, non-woven polyester fabric surfaced, SBS,modified bitumen roof underlayment. i 4.2 Lastobond Shield is a self-adhering, woven polyethylene surfaced,I:SBS modified bitumen roof junderlayment available in two widths;36 and 45 inch. 4.3 RESISTO SA SMOOTH PLY 40 is a self-adhering, woven polyethylene surfaced,SBS modified bitumen roof underlayment;available in 3.3 ft x 65 ft rolls. Exterior Research and Design,U.C. ;Evaluation Report 518010.06.09-1110 CertificateafAuthorization#9503 FBCNON-HVHZEVALUATION FL2569-R12 Soprerna,Inc. I Revision 10:06/12/2017 Page 2 of 7 P' l I, : RI ERD 4.4 Lastobond Shield HT is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment. 4.5 Lastobond Pro HT-N is a self-adhering, woven polyethylene surfaced; SBS modified bitumen roof underlayment available in two widths;36 and 45 inch. I 4.6 Lastobond Pro HT-S is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment. �! 4.7 Lastobond 195 is a self-adhering, glass-mat reinforced, sand-surfaced; SBS modified bitumen roof underlayment. 4.8 Lastobond Eaves Protection Sheet is a self-adhering, glass-mat reinforce , sandsurfaced, SBS modified I' bitumen roof underlayment. I � 4.9 Lastobond Eco is a self-adhering, glass-mat reinforced, sand-surfacedI;; SBS modified bitumen roof underlayment. 4.10 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced, film-surfaced; SBS modified bitumen roof underlayment. l 4.11 RESISTO LB1236 is a self-adhering, glass-mat reinforced, sand isurfaced: SBS modified bitumen roof underlayment,with a 36-inch sheet width. 4.12 PrimeSource Grip-Rite Eave&Valley Protector is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment,with a 36-inch sheet width. 4.13 RESISTO LB1244 is a self-adhering, glass-mat reinforced, sand;surfaced, SBS modified bitumen roof underlayment,with a 44-inch sheet width. 4.14 Col hens FR GR is a self-adhering, fiberglass reinforced � p g, g , granul I-surface'd, SBS;modified bitumen roof underlayment. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Repo1r't, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose; I 5.2 This Evaluation Report is not for use in the HVHZ. !! 5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire j ratings of this product. I 5.4 Soprema Roof Underlayments may be used with any prepared roof,cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made,to the Authority Having Jurisdiction for approval based on this evaluation combined with 'supporting data for the prepared roof covering. 5.5 Allowable roof covers applied atop the underlayments are follows-- 1 TAOLE 1. ROOF COVER;OPTIONS- f,j Asphalt Nail-On Foam-On k Wood Shakes& underlayment Metal Slate Shingles Tile Tile Shingles Lastobond TU HT Yes Yes Yes i, Yes Yes Yes See 5.5.11 Lastobond Shield/Pro HT-N/ RESISTO SA SMOOTH PLY 40 Yes No No 1; Yes Yes i I !I Lastobond Shield HT/Pro HT-S Yes No No it Yes Yes Yes Lastobond Eaves Protection Sheet/Lastobond 195 Yes No No No Yes Yes I: i Exterior Research and Design,LLC. Evaluation Report 518010.06.09-R10 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION 1`1_2569-R12 Soprema,Inc. Revision 10:06/12/2017 l Page 3 of 7 I , it , I . TRINITY.ERD TABLE 1: ROOF COVER:.OPTIONSiI l: Asphalt Nail-On Foam-On + MWood Shakes& Slate Underlayment Shingles Tile Tile Mi gal Shingles Lastobond ECO /RESISTO LB1236,Grip-Rite Eave&Valley Yes No No No Yes Yes Protector/RESISTO LB1244 I,! Lastobond Smooth Seal HT Yes No Noes Yes Yes Colphene FR GR Yes Yes Yes No Yes Yes See 5.5.1 I,i' jl II ' 5.5.1 "Foam-On Tile" is limited to use of the following adhesives unless tensile 6dhesion/long term aging data from an accredited testing laboratory is provided. Underlayment Adhesive(s) Lastobond TU HT ICP Adhesives"Polyset AH-160"(FL6332);Dow Chemical"TileBondr"Roof Tile Adhesive"(FL717) I Colphene FR GR ' ICP Adhesives"Polyset AH-160"(FL6332) I ' 5.6 Allowable substrates are noted below: I I' 5.6.1 Direct-Bond to Deck: (' Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastol;bond Shield HT, Lastobond Pro HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 1195, Lastobond ECO, RESISTO LB1236,Grip-Rite Eave&Valley Protector,RESISTO LB1244 or Lastobond Smooth Seal HT applied to: ➢ Plywood;ASTM D41 primed plywood; OSB;ASTM D41 primed OSB; Southern;,Yellow Pine; ASTM D41 primed Southern Yellow Pine;ASTM D41 primed structural conlcrete. Colphene FR GR applied to: i Plywood;ASTM D41 primed plywood;ASTM D41 primed structural con rJrete. Note: While not required over plywood, OSB or Southern Yellow Pine substrates; Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final roof clover is not slated for installation within { 24 hours. > Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the self-adhering underlayment. j 5.6.2 Bond-to-Insulation: i Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond`1195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave&Valley Protector, RESISTO LB1244,Lastod'ond Smooth Seal HT or Colphene FR GR applied to: i j r Dens Deck Prime;SECU ROCK Gypsum-Fiber Roof Board. j For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations I under foam-on tile systems(Lastobond TU HT only),insulation attachment!shall be designed by a qualified design professional and installed based on testing of the insulatilon/underlayment system in accordance with FM 4474,Appendix D or TAS 114,Appendix J. I ' I I; I ,I I � I � ' i' Exterior Research and Design,LLC. I ; Evaluation Report 518010.06.09-R10 Certificate of Authorization 119503 FBC NON-HVHZ EVALUATION i FL2569-R12 Soprema,Inc. Revision 10:06/12/2017 Page 4 of 7 i I' ' TRINITY;ERD 5.6.3 Bond to Mechanically Attached Base Layer: Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond i195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave&Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to: v ASTM D226,Type I or II felt;Sopra-G;Modified Sopra-G. For installations under mechanically attached i prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam-on, syseems (Lastobond TU HT only), base layer shall be attached in accordance with FRSA/TRI April 2011 5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications!:;' FRSA%TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems, where the underlayment forms part of the load-path. The following wind plift lirriitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) an are used in foam-on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margir'.of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04-12)Or FBC 1609 fogy determination of design wind pressures. - 5.6.4.1 Maximum Design Pressure=-45.0 psf: I i' Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. j Primer: (Optional)Elastocol Stick,Elastocol 600c or RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered. 5.6.4.2 Maximum Design Pressure=-67.5 psf: I Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. it Primer: Elastocol 600c Underlayment: Lastobond TU HT or Colphene FR GR,self-adher d. li 5.6.4.3 Maximum Design Pressure=-150.0 psf: Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project { requirements to satisfaction of Authority Having!13 urisdiction. Deck Preparation: Plywood shall be thoroughly cleaned to remove dust'and 'debris that may inhibit jadhesion. All sheathing fasteners shall be driven flush with! the surface. All sharp splinters and wood projections shall be removed%sandedt, I Primer: (Optional)RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT, self-adhered, shall be thoroughly ,roll using hand roller and/or weighted roller to ensure there are no voids, and ensure:there: no voids/bridging at side and end-laps. Ij 5.6.4.4 Maximum Design Pressure=-60.0 psf: I , j Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and;,6-inch o.c. in three (3), equally spaced rows in the center of the sheet. Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered i I, i Exterior Research and Design,U.C. Evaluation Report 518010.06.09-1110 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION i i F1.2569-1112 Soprema,Inc. I Revision 10:06/12/2017 Page'5 of 7 I' I TRINFY ER 5.7 Exposure Limitations: Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco Lastobond Smooth Seal HT, RESISTO LB1236, Grip-Rite Eave&Valley Protector or RESISTO L81244 shall not be heft exposed for longer than 30- I i' I days after installation. I I Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 0, Lastobond (Shield HT or Lastobond Pro HT-S shall not be left exposed for longer than 90-days after installation.l Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than 180-days after installation. { i 6. INSTALLATION: I 6.1 Soprema Roof Underlayments shall be installed in accordance; with Soprema published installation requirements subject to the Limitations set forth in Section 5 herein and the:specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER (if applicable). I! Ii 6_3 Lastobond TU HT,Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield IHT, Lastobond Pro HT-S, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond Eco, Lastobond Smooth Seal HT,RESISTO LB1236,Grip-Rite Eave&Valley Protector,REST' O LB1244 or Colphene FR GR: 6.3.1 Shall be installed in compliance with the requirements for ASTM( D1970underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 Non-Tile Applications: II While priming is optional, Soprema recommends priming with Elastocol Sdck, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof cover is not slated for installatioriiwithin 32:4 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft.of membrane and peel back the first 3 ft of release film. I Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place, peel-off the release film diagonally while holding the membrane tight. Firmly roll the membrane into place to achieve a bond. I Horizontal seams should be minimum 3-inches, configured to shied water. Vertical seams should be 6- inches and staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps shall be sealed using either heat-welding or hot air welding techniques. I When installing at slopes above 8:12, Soprema recommends back nailing i r i the overlap area at the top of the sheet at 12-inch o.c. II For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the;release paper and center sheet 1 over valley or ridge. Drape and press sheet into place, working from thelcenter'of the valley or ridge in each direction. For valleys,apply the sheet starting at the lowest pioint andi,work upward. II I� 6.3.3 Tile Applications(Lastobond TU HT or Colphene FR GR only): Reference is made to FRSA/TRI April 2012 (04-12) Installation 'Manual land Table 1 herein, using the instructions noted above as a guideline. For foam-on the applications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012(04-12). i' Tile shall be loaded and staged in a manner that prevents the slippage 'and/or damage to the underlayment. ' i I � II, i, Exterior Research and Design,U.C. Evaluation Report 518010.06.09-1110 Certificate of Authorization#950.3 FBC NON-HVHZ EVALUATION i F1.2569-1112 Soprema,Inc, i i Revision 10:06/12/2017 I Page 6 of 7 I, - i I I: ' II • I i aIN :ERD 6.3,3.1 Lastobond TU HT has met the tile slippage test requirements specified in FRSA/TRI April 2012(04-12) up to a 10-tile stack to a maximum roof pitch of 6:12 for flat tiles and 5�12 for IlLigged tiles. Lugged tiles staged at pitch>5:12 may use alternate staging method (bottom 2-tile stalck shall be inverted,followed by 8 tiles^ I I' high on slope,as shown below) 14 i i�fl� I i• t t�q .c l N� } F f A2 I. Figure 1: Alternate Staging.Mellhod 11 Alternatively, at roof slopes greater than these limitations, all tllesishall be,loaded onto a nominal 1"x 2" horizontal batten to prevent slippage or damage to the underlayment l 6.3.3.2 Coiphene FR GR has met the file slippage test requirements specified in FRSA/TRI:April 2012(0412)up to a 10-tile stack to a maximum roof pitch of 5:12 for flat tiles and 6:112 for lugged tile's. At roof slopes greater than these limitations,all tiles shall be loaded onto a nominal 1"x 12" horizontal batten to prevent slippage or damage to the underlayment. l 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order; to properly evaluate the installation of l this product. I Y S. MANUFACTURING PLANTS: !. Contact the manufacturer or the named QA entity for information on pilants covered under Rule 61G20-3 QA requirements. I 9. QUALITY ASSURANCE ENTITY: UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com -END OF EVALUATION REPORT- 1 I I' Exterior Research and Design,LLC. I„ Evaluation Report S18010.06.09-1110 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL2569-1112 Soprema,Inc. Revision 10:06/12/2017 Page 7 of 7 i