HomeMy WebLinkAboutProduct Approval Florida Building Code Online �'' Page 1 of 2
„I
Jrltb ti�Y+ I�$y k zf 1} ;�
1
BQS Home Log In User Registration Hot Topics Submit Surcharge - Stats&Facts Publications FBC Staff BCIS Site Map Links Search
Product flL�ity'
i
C,�- USER:Public Approval
,
1
I
Product Approval Menu>Product or Application Search> 1
Qpolication List>Application Detail
rt FL FL2569 R12
g, Application Type Revision f
Code Version 2014 I ;
Application Status Approved
I
Comments
Archived
Product Manufacturer Soprema,Inc. (Canada) j
Address/Phone/Email 1640 rue Haggarty I
Drummondville, NON-US o00oo
(819)478-2400 I I
memathieu@soprema.ca
Authorized Signature Marc-Etienne Mathieu I ;
memathieu@soprema.ca
I � I
Technical Representative Marc-Etienne Mathieu
Address/Phone/Email 1688 Jean-Berchmans-Michaud
Drummondville, NON-US 00000
(819)478-2400 Ext 3327,
memathieu@soprema.ca
Quality Assurance Representative Jean-Francois Cote,Ph.D.
I
Address/Phone/Email 1640 rue Haggarty I
Drummondville
(888)811-3145
j fcote@soprema.ca
I Category Roofing
Subcategory Underiayments
I!i I
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer I I
I Evaluation Report-Hardcopy Received '
II;
Florida Engineer or Architect Name who developed Robert J. M. Nieminen j
the Evaluation Report
Florida License PE-59166
f
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 07/17/2020
I
Validated By John W. Knezevich,PE
J Validation Checklist-Hardcopy Received
Certificate of Independence FL2569 R12 COI 2017 01-1 COI Ni el
Referenced Standard and Year of Standard
I ( ) Standard Year
j ASTM D1970 I!j 2009
ASTM D6163 2000
ASTM D6164 I i 2005
FM 4474 2004
FRSA/TRI April 2012(04-12) 2012
TAS 103 I 1995
TAS 110 2000
UL 1897 I 2004
Ili a
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?paranI=wGEVXQwtDgsK( FEnc1cB10... 11/1/2017
Florida Building Code OnlinePage 2 of 2
I '
Equivalence of Product Standards
Certified By
I I
Sections from the Code
I '
Product Approval Method Method 1 Option D ! I
Date Submitted 06/12/2017 I
Date Validated 06113/2017 I
I
Date Pending FBC Approval 06/15/2017
Date Approved 08/08/2017
Date Revised 10/09/2017 i
Summary of Products
FL# Model,Number or Description i I
Name i
2569.1 Soprema Roof Self adhering roof underlayments
Underlayments
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL2569 R12 II 2017 06 FINAL ER S-0PREM`A'CA UNDERLAYh1ENTS FL2569- f
Approved for use outside HVHZ:Yes R12.1)df
Impact Resistant:N/A Verified By: Robert Nieminen,P.E. PE-59166
Design Pressure:+N/A/-150 Created by Independent Third Party:Yes
Other: 1.)Refer to ER Section 5 for Evaluation Reports
I ill I
Limits of Use.2.)The design pressure FL2569 R12 AE 2017 06 F114AL Eli SOPREMA CA UNDERLAYMENTS 1`1_2569-
noted herein pertains to underlayment R12.adf I
systems used beneath adhesive-set tile Created by Independent Third Party::Yes
j systems.Refer to ER Section 5.6.4 for
details. I
I i
I I.
Back Next 1
t
I
i
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-18 24 i
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida ::Privacy Statement::Acc Inability Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395."Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However'email addresses are public record.If you do not wish to
i supply a personal address,please provide the Department with an email address which can be made available to the pulilic.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
I
Product Approval Accepts:
I I
I I
CreCirt t,'ard
Safe
_ 'I
I '1
Ij
II ,
I
i I '
' II.
I � I
http;//www.floridabuildincy.ora-/t)r/pr_app_dtl.aspx?param=wGEVXQwtDdsKQFEnckB 10... 11/1/2017
I
i
I
EXTERIORIRESEARCH&DESIGN, LLC.
Certifrcate of Authorization#9503
• ��� 353-CHRISTIAN STREET,UNIT#13
ERD
I OXFORD,CT 06478
(203)262-9245
EVALUATION REPORT I ;
Soprema, Inc. Evaluation Report S18010.06.09-1110
1640 rue Haggerty I FL2569-R12
Drummondville,Quebec J2C 5P8 Canada j Date of:Issuance:06/15/2009
(819)478-2400 ;i Revision 10:06/12/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted hasibeen reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential,Volume. The
products described herein have been evaluated for compliance with the 5th Edition (e 014) 'Florida Building Code
sections noted herein.
DESCRIPTION: Soprema Roof Underlayments ;
i
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the pr9cluct change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this'
Evaluation Report relative to updated Code requirements with each Code Cycle. I j
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinityi'ERD Evaluated" may be displayed in
advertising literature, if any portion of the Evaluation Report is displayed,then it'shall b done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to thle user by the manufacturer or
I �
its distributors and shall be available for inspection at the job site at the request of the Buslding Official.
This Evaluation Report consists of pages 1 through 7. I
I•
Prepared:by:
a�• •�; ter,, � i
{ Robert J.M.Nieminen,P.E. Th(facsimile sealiappearing was authorized by Robert Nieminen,
�r•; �, ==•''•r'_ P.E!on 06/12/2017.This does not serve as an electronically signed
Florida Registration No.59156,Florida DCAANE1983 '•° ti
i_r,,rJ�rir n�t�•is dociument.S(gnetl;sealed hardmpies have been transmitted to the
- Product Approval`Administrator and to the named client
CERTIFICATION OF INDEPENDENCE: I
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial;interest Iii any company manufacturing or
distributing products it evaluates. j
2. Trinity)ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which!the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product. i
S. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
II'
I
I.
Ili
i � I
i
I,
.:-,' TRINITY:,ERD
J
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the
following sections of the Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations/Conditions of fJse set forth herein.
2. STANDARDS:
I
Section Property Standard Year
1504.3.1 Wind Resistance. FM 4474 I 2004
1504.3.1 Wind Uplift UL 1897 i 2004
1507.2.4,1507.2.8, Physical Properties ASTM D1970 { 2009
1507.2.9.2,1507.4.5.1,
i
1507.5.3,1507.7.3
1507.11.2 Physical Properties ASTM D6163 2000
1507.11.2 Physical Properties ASTM D6164 2005
1523.6.5.2.1 Physical Properties TAS 103 1995
TAS 110 Accelerated Weathering TAS 110 ! 2000
I 1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012
i
3. REFERENCES: I I
! l
Enti Examination Reference Date
I ERD(TST6049) ASTM D1970/TAS 110 2968.05.04;;-2 ;'I 05/14/2004
ERD(TST6049) Physical Properties 2757.02.05 02/03/2005
ERD(TST6049) ASTM D1970/TAS 110 2974.03.05 2 05/17/2005
ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005
ERD(TST6049) Wind Resistance 2779.11.05-111 04/18/2007
ERD(TST6049) TAS 103/TAS 110 57120.11.07-2 11/02/2007
ERD(TST6049) ASTM D1970/TAS 110 513190.02109-R1 I 04/01/2010
ERD(TST6049) ASTM D1970/TAS 110 531370.03 110-1-R11: 04/07/2010
! 1 ERD(TST6049) Physical Properties/Tensile Adhesion S11150.05.!10-RI 09/09/2010
ERD(TST6049) Physical Properties/Tensile Adhesion S111S0.05,09-112 I 10/05/2010
ERD(TST6049) ASTM D1970 537210.11:11 111/09/2011
ERD(TST6049) ASTM D1970 540540.02!13-1 I { 02/19/2013
ERD(TST6049) Physical Properties/Tensile Adhesion 543530.02i14-1 I 02/21/2014
ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/13/2015
! ERD(TST6049) Accelerated Weathering SOPC-SC8520. 14 1 04/17/2015
ERD(TST6049) Wind Resistance SOPC-SC14045.05.17 R1 06/07/2017
M-D(CER1592) HVHZ Compliance 15-0508.04 ! i 09/24/2015
jICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 J I 03/01/2017
PRI(TST5878) Physical Properties SOP-064-02-01 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 05/29/2015
UL,LLC(QUA9625) Quality Control Service Confirmation; Exp.10/16/2017
4. PRODUCT DESCRIPTION: '
4.1 Lastobond TU HT is a self adhering, non-woven polyester fabricsurfaced, SBS'modified bitumen roof
underlayment.
4.2 Lastobond Shield is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment available in two widths;36 and 45 inch.
I 4.3 RESISTO SA SMOOTH PLY 40 is a self-adhering, woven polyethylene surfaced,SBS modified bitumen roof
underlayment;available in 3.3 ft x 65 ft rolls.
Exterior Research and Design,LLC. Evaluation Report S.18020.06.09-11 10
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION F1.2569-1112
i
Soprema,Inc. I Revision 10:06/12/2017
Page 2 of 7
`t
' I
i ,
i
IF
4.4 Lastobond Shield HT is a self-adhering, woven polyethylene surfaced, high� temperature, SBS modified
bitumen roof underlayment,
I ,
4.5 Lastobond Pro HT-N is a self-adhering, woven polyethylene surfaced, 'SBS modified bitumen roof
underlayment available in two widths;36 and 45 inch.
4.6 Lastobond Pro HT-S is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified
bitumen roof underlayment.
4.7 Lastobond 195 is a self-adhering, glass-mat reinforced, sand-surfaced;!SBS modified bitumen roof
underlayment.
4.8 Lastobond Eaves Protection Sheet is a self-adhering, glass-mat reinforced, sandL surfaced, SBS modified
bitumen roof underlayment. 1
4.9 Lastobond Eco is a self-adhering, glass-mat reinforced, sand-surfaced; SBS modified bitumen roof
underlayment.
4.10 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced, film-srrfaced, SBS modified bitumen
froof underlayment. i
4.11 RESISTO LB1236 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS 'modified bitumen roof
underlayment,with a 36-inch sheet width. I'
I ,
j 4.12 PrimeSource Grip-Rite Eave&Valley Protector is a self-adhering,glass-malt reinforced,sand-surfaced,SBS
j modified bitumen roof underlayment,with a 36-inch sheet width. I'
I�!
4.13 RESISTO LB1244 is a self-adhering, glass-mat reinforced, sand-"surface SBS SBS 'modified bitumen roof
underlayment,with a 44-inch sheet width. j
4.14 Colphene FR GR is a self-adhering, fiberglass reinforced, granule-surfaced, SBS-modified bitumen roof
underlayment.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity ERD nor Robert Nlem�'ilien, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire
ratings of this product. i
5.4 Soprema Roof Underlayments may be used with any prepared roof,cover where the product is specifically
f referenced within FBC approval documents. If not listed, a request may be,made;to the Authority Having
j Jurisdiction for approval based on this evaluation combined with Isupport
ing data for the prepared roof
covering.
5.5 Allowable roof covers applied atop the underlayments are follows
TABLE!-.:ROOF COVER OPTIONS
Asphalt Nail-On Foam-On wood Shakes&
Underlayment Metal Slate
Shingles Tile Tile I j Shingles
Lastobond TU HT Yes Yes Yes Yes Yes Yes
See 5.5.1
Lastobond Shield/Pro HT-N
j Yes No No No Yes Yes
RESISTO SA SMOOTH PLY 40
Lastobond Shield HT/Pro HT-S Yes No No Yes Yes Yes
Lastobond Eaves Protection Yes No No !No Yes Yes
Sheet/Lastobond 195
Exterior Research and Design,LLC. Evaluation Report518410.06.09-R1D
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION I FL2569-R12
Soprema,Inc, i Revision 10:06/12/2017
Page 3 of 7
lig
, i i
TRINITY
TABLE i: ROOF COVER OPTIONS;
Underlayment Asphalt Nail-On Foam-On! Metal (Wood Shakes& Slate
Shingles Tile Tile I!j Shingles
Lastobond ECO /RESISTO
LB1236,Grip-Rite Eave&Valley Yes No No N,0 Yes Yes
Protector/RESISTO LB1244 j j
Lastobond Smooth Seal HT Yes No No Yes Yes Yes
Colphene FR GR Yes Yes Yes No Yes Yes
See 5.5.1;
5.5.1 "Foam-On Tile" is limited to use of the following adhesives unless tensile adhesion/long term aging data
from an accredited testing laboratory is provided. i
Underlayment Adhesive(s)
Lastobond TU HT ICP Adhesives"Polyset AH-160"(FL6332);Dow Chemical"TileBond"`Roof Tile Adhesive"(FL717)
Colphene FR GR ICP Adhesives"Polyset AH-160"(FL6332) a
5.6 Allowable substrates are noted below:
5.6.1 Direct-Bond to Deck: I'
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond ]:95, Lastobond ECO, RESISTO
LB1236,Grip-Rite Eave&Valley Protector,RESISTO LB1244 or Lastobond Smooth Seal HT applied to:
> Plywood;ASTM D41 primed plywood;OSB;ASTM D41 primediOSB;Southern:Yellow Pine; ASTM D41
j primed Southern Yellow Pine;ASTM D41 primed structural concrete.
Colphene FR GR applied to:
i Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete.
Note: I
y While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends
i 1h
priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within
24 hours.
Soprema requires tongue-and-groove board decking be cowered width plywood or OSB prior to
installation of the self-adhering underlayment.
j 5.6.2 Bond-to-Insulation:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond ,195, Lastobond ECO, RESISTO
LB1236, Grip-Rite Eave&Valley Protector, RESISTO LB1244,Lastobond Smooth Seal HT or Colphene FR GR
applied to:
> Dens Deck Prime;SECU ROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, it ilsulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam-on the systems (Lastobond TU HT only), insulation attachment)shall be designed by a qualified
design professional and installed based on testing of the insulation/under•iayment system in accordance
iwith FM 4474,Appendix D or TAS 114,Appendix J.
Exterior Research and Design,I.I.C. ?Evaluation Report 518010.06.09-R10
Certificate ofAuthorivation#9503 FBC NON-HVHZ EVALUATION F1.2569-1112
Soprema,Inc. ' Revision 30:06/12/2017
Page 4 of 7
� I
'I
I
TRINTY ER
5.6.3 Bond to MechanicallV Attached Base Laver:
LastobondShield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 1195, Lastobond ECO, RESISTO
LB1236, Grip-Rite Eave&Valley Protector, RESISTO LB1244, Lastobond SmolI oth Seal HT or Colphene FR GR
applied to: ,
v ASTM D226,Type I or 11 felt;Sopra-G;Modified Sopra-G.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam-on tile systems (Lastobond TU HT only),
base layer shall be attached in accordance with FRSA/TRI April 2012(04-12);
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: 'FRSA%TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment system's beneath foam-on tile systems, where.
the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment
systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam-ori the applications.
Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,
and reflects the ultimate passing pressure divided by 2 (the 2 to'1 margin!of safety per FBC 1504.9 has
already been applied). Refer to FRSA/TRI April 2012(04-12)or FBC 1609 fll rdeterimination of design wind
I pressures. L
j 5.6.4.1 Maximum Design Pressure=-45.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
I i
Primer: (Optional)Elastocol Stick,.Elastocol 600c or RESISTO EXTERIOR PRIMER
I Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered.
5.6.4.2 Maximum Design Pressure=-67.5 psf: i
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction. i
Primer: Elastocol600c
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered. JJ
iI
5.6.4.3 Maximum Design Pressure=-150.0 psf:
Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-slide up) to meet project
requirements to satisfaction of Authority Having"Jurisdiction.
I Deck Preparation: Plywood shall be thoroughly cleaned to remove dust i and debris that may inhibit
adhesion. All sheathing fasteners shall be driven flush with; the surface. All sharp
j splinters and wood projections shall be removed/sanded.;
Primer: (Optional)RESISTO EXTERIOR PRIMER I
Underlayment: Lastobond TU HT, self-adhered, shall be thorioughly roll using hand roller and/or
weighted roller to ensure there are no voids, and ensure'therelare no voids/bridging at.
side and end-laps.
5.6.4.4 Maximum Design Pressure=-60.0 psf:
I
Deck: Min. 19/32-inch plywood to meet project requiremei'ts to satisfaction of Authority
i Having Jurisdiction.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin
caps (FBC 1517.5.2) spaced 6-inch o.c, at the 4-inch laps and!6-inch o.c. in three (3),
equally spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered
'i
f
I
Exterior Research and Design,LLC. Evaluation Report 518010.06.09-1130
Certificate of Authorization 119503 FBC NON-HVHZ EVALUATION i FL2569-R12
Soprema,Inc. Revision 10:06/12/2017
i Page 5 of 7
i
I
j
i I
i
I'I
' E
i;
5.7 Exposure Limitations: i
Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, Lastobcmcl Smooth Seal HT, RESISTO
LB1236, Grip-Rite Eave&Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30-
days after installation.
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY;40 Lasi oibond;Shield HT or Lastobond
Pro HT-S shall not be left exposed for longer than 90-days after installation.1`I
Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than'180-days after installation.
i
6. INSTALLATION: i
i
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation
requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate with Elastocol Stick, Elastocol
600c or RESISTO EXTERIOR PRIMER (if applicable).
6.3 Lastobond TU HT,Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield
HT, Lastobond Pro HT-S, Lastobond Eaves Protection Sheet Lastobond x:95, Lastobond Eco, Lastobond
Smooth Seal HT RESISTO LB1236,Grip-Rite Eave&ValleV Protector,RESISTO LB1244 or Colphene FR GR:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970.,underlayment in FBC Sections
1507 for the type of prepared roof covering to be installed.
6.3.2 Non-Tile Applications: I i
While priming is optional, Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO
EXTERIOR PRIMER if the final roof cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining'membra'ne as far as possible.
Once the entire length of membrane is in place, peel-off the release fillrrl diagonally while holding the
membrane tight. Firmly roll the membrane into place to achieve a'bond.
Horizontal seams should be minimum 3-inches, configuredto shed water: Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps
shall be sealed using either heat-welding or hot air welding techniques.
When installing at slopes above 8:12, Soprema recommends back-nailing in.the overlap area at the top of
the sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths.Peel the'release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from thelcenter-of the valley or ridge in
each direction. For valleys,apply the sheet starting at the lowest point and;work upward.
I 6.3.3 Tile Applications(Lastobond TU HT or Colphene FR GR only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
For foam-on tile applications,reference is made to Section 5.6.4 herein for'''Wind resistance limitations that
fall outside the scope of FRSA/TRI April 2012(04-12).
Tile shall be loaded and 'staged in a manner that prevents;tile slippage and/or damage to the
underlayment. '
I,I
II,
Exterior Research and Design,U.C. I 'Evaluation Report 518010.06.09-1110
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL2569-1112
Soprema,Inc. I Revision 10:06/12/2017
Page 6 of 7
I
I,
I; TRINITY !,ER
6.3.3.1 Lastobond TU HT has met the tile slippage test requirements specified in FRSA/TRI April 2012(04-12) up
to a 10-tile stack to a maximum roof pitch of 6:12 for flat tiles and 5:12 for I�u ged tiles. Lugged tiles staged
at pitch>5:12 may use alternate staging method (bottom 2-tile stack shall'i ie inverted,followed by 8 tiles
high on slope,as shown below) i
tis
IN,
I I i
- t
c -
3
I
_3 �J
{ 4 4 y , testi.
L �
C
Sy 1 2 j. 3, •+>" ' 1.Iii€; !f k1 ti
Figure 1: Alternate Staging Method
I I ,
Alternatively, at roof slopes greater than these limitations, all tilesishall be loaded onto a nominal 1"x 2"
horizontal batten to prevent slippage or damage to the underlayment
6.3.3.2 Colphene FR GR has met the the slippage test requirements specified in FRSA/TRI April 2012(04-12)up to
j a 10-tile stack to a maximum roof pitch of 5:12 for flat tiles and 6:12 for lugged tiles. At roof slopes greater
than these limitations,all tiles shall be loaded onto a nominal 1"x2" horizontal batten to prevent slippage
or damage to the underlayment.
7. BUILDING PERMIT REQUIREMENTS: !1
As required by the Building Official or Authority Having Jurisdiction in orderlto propefly evaluate the installation of
this product. i
8. MANUFACTURING PLANTS:
I
Contact the manufacturer or the named QA entity for information on plants covered under Rule 61G20-3 QA
requirements.
9. QUALITY ASSURANCE ENTITY:
f � I I
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
' II
i
1
1
i I �
I I
I
Exterior Research and Design,LLC. 1Evaluation Report 518010.06.09-1110
Certificate of Authorization 119503 FBC NON-HVHZ EVALUATION I FL2569-1112
Soprema,Inc. I Revision 10:06/12/2017
Page 7 of 7
I ; '
Ii
I I �