HomeMy WebLinkAboutproduct approval I ,
I
TRINITY,ERD
TABLE 1:'--ROOF COVER OPTIONS,.
Asphalt Nail-On Foam-On I Wood Shakes&
Underlayment Slate
Shingles Tile Tile Metal Shingles
Lastobond ECO /RESISTO I I
LB1236,Grip-Rite Eave&Valley Yes No No I No Yes Yes
Protector/RESISTO LB1244
Lastobond Smooth Seal HT Yes No No Yes Yes Yes
Colphene FR GR Yes Yes Yes. Na' j Yes Yes
See 5.5.1 .1;
5.5.1 "Foam-On Tile" is limited to use of the following adhesives unless tensile adhesion/long term aging data
from an accredited testing laboratory is provided. I "
I
Underlayment Adhesive'(s)
Lastobond TU HT ICP Adhesives"Polyset AH-160"(FL6332);Dow Chemical"Tile69nd'Roof Tile Adhesive"(FL717)
Colphene FR GR ICP Adhesives"Polyset AH-160"(FL6332)
5.6 Allowable substrates are noted below:
5.6.1 Direct-Bond to Deck: I
j Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lasto'bpnd Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond [195, Lastobond ECO, RESISTO
LB1236,Grip-Rite Eave&Valley Protector,RESISTO LB1244 or Lastobond Smooth Seal HT applied to:
➢ Plywood;ASTM D41 primed plywood; OSB;ASTM D41 primed,OSB;SOLithern;Yellow Pine; ASTM D41
primed Southern Yellow Pine;ASTM D41 primed structural concrete.
Colphene FR GR applied to: i
v Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete.
Note: i,'
➢ While not required over plywood, OSB or Southern Yellow Pine suf'strates Soprema recommends
priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within
24 hours.
9 Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to
installation of the self-adhering underlayment.
5.6.2 Bond-to-Insulation:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond)J195, Lastobond ECO, RESISTO
LB1236, Grip-Rite Eave&Valley Protector, RESISTO LB1244,Lastobond Smooth Seal HT or Colphene FR GR
applied to:
9 Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, ins ulatioh shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam-on the systems(Lastobond TU HT only), insulation attachmeni'shall be designed by a qualified
design professional and installed based on testing of the insulation /underlayment system in accordance
with FM 4474,Appendix D or TAS 114,Appendix J. j
I�
i I
I
i
I `
I.
Exterior Research and Design,I.I.C. ,Evaluation Report S18010.06.09-R10
Certificate ofAuthori:ation 119503 FBC NON-HVHZ EVALUATION FL2569-1112
Soprema,Inc. Revision 10:06/12/2017
Page 4 of 7
1 I .
I ( np��Jy'i�gyp}' g!�'�9p @��5��y'$�'y$
• ! I4 GB ai U Y 'tl..�i®.wi
, I I
5.6.3 Bond to Mechanically Attached Base Layer:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
LB1236,Grip-Rite Eave&Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR
! applied to: 1,
v ASTM D226,Type I or II felt;Sopra-G;Modified Sopra-G.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam-on!the systems (Lastobond TU HT only),
base layer shall be attached in accordance with FRSA/TRI April 2012(04-12);.
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications:'!FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment system's beneath foam-on tile systems, where
the underlayment forms part of the load-path. The following wind uplift lirriitations apply to underlayment
systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam-on tile applications.
Maximum Design Pressure is the'result of testing for wind load resilstance based on allowable wind loads,
and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin)of safety per FBC 1504.9 has
already been applied). Refer to FRSA/TRI April 2012(04-12)or FBC 1609 for'deterinination of design wind
pressures.
5.6.4.1 Maximum Design Pressure=-45.0 psf:
Deck: Min. 15/32-inch plywood to meet project requiremeri'ts to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional)Elastocol Stick,Elastocol 600c or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered.
5.6.4.2 Maximum Design Pressure=-67.5 psf: I I'
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Elastocol 600c
Underlayment: Lastobond TU HT or Colphene FR GR,self-adherei. j
5.6.4.3 Maximum Design Pressure=-150.0 psf:
Deck: Min. 15/32-inch APA-rated BCX plywood (may be insta,lbed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction. f
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust,and debris that may inhibit
adhesion. All sheathing fasteners shall be driven flush), with,the surface. All sharp
splinters and wood projections shall be removed/sanded:
Primer: (Optional)RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, self-adhered, shall be thoroughlyi roll using hand roller and/or
weighted roller to ensure there are no voids, and ensure there�are no voids/bridging at
side and end-laps.
5.6.4.4 Maximum Design Pressure=-60.0 psf: i
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin
caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and;6-inch o.c. in three (3),
equally spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered I
I
II'
Exterior Research and Design,LLC. I` Evaluation Report S18010.06.09-R10
Certificate of Authorization#9503 FBC NON-HVHZ EVAWATION FL2569-1112
Soprema,Inc. Revision 10:06/12/2017
Page 5 of 7
r ,
1 I ll
, II,
I � i
i I
I ;
I KINI I Y
5.7 Exposure Limitations: I
Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco; Lastobond Smooth Seal HT, RESISTO
LB1236, Grip-Rite Eave&Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30-
days after installation.
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond;Shield HT or Lastobond
Pro HT-S shall not be left exposed for longer than 90-days after,installation 1, ; !
Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than 180-days after installation.
!
6. INSTALLATION:
6.1 Soprema Roof Underlayments shall be installed in accordance' with Soprema published installation
requirements,subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly
to remove any.dust and debris prior to application,and prime the substrate,with Elastocol Stick, Elastocol
600c or RESISTO EXTERIOR PRIMER (if applicable). I i,
6_3 Lastobond TU HT,Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield
HT, Lastohond Pro HT-S, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond Eco, Lastobond
Smooth Seal HT,RESISTO LB1236,Grip-Rite Eave&Valley Protector,RESISi'O LB1i244 or Colphene FR GR:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970,landerlayment in FBC Sections
1507 for the type of prepared roof covering to be installed.
6.3.2 Non-Tile Applications: I
While priming is optional, Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO
EXTERIOR PRIMER if the final roof cover is not slated for installation within 24 hour's.
Apply sheet parallel to.the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining!membrane as far as possible.
Once the entire length of membrane is in place, peel-off the release film diagonally while holding the
membrane tight. Firmly roll the membrane into place to achieve a bond. !
Horizontal seams should be minimum 3-inches, configured to shed watd'r. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course Below. All over-granule end-laps
shall be'sealed using either heat-welding or hot air welding techniques. I
When installing at slopes above 8:12, Soprema recommends back nailing in,the overlap area at the top of
the sheet at 12-inch o.c. !
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths.(Peel the irelease paper and center sheet
over valley or ridge. Drape and press sheet into place, working from thel center of the valley or ridge in
each direction. For valleys,apply the sheet starting at the lowest point andiwork upward.
6.3.3 Tile Applications(Lastobond TU HT or Colphene FR GR only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manualhand Table 1 herein, using the
instructions noted above as a guideline.
For foam-on tile applications, reference is made to Section 5.6.4 herein for';wind resistance limitations that
fall outside the scope of FRSA/TRI April 2012(04-12). !
i�
Tile shall be loaded and staged in a manner that prevents!tile slippage and/or damage to the
underlayment. !'
I ,
i,
Exterior Research and Design,LLC. i !,Evaluation Report 518010.06.09-1110
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATIONF1.2569-1112I
Soprema,Inc. i ! Revision 10:06/12/2017
Page 6 of 7
li
i I .
f !,
ER
TRINITY',
6.3.3.1 Lastobond TU HT has met the tile slippage test requirements specified in FRSA/TRI April 2012(04-12) up
to a 10-tile stack to a maximum roof pitch of 6:12 for flat tiles and 5:12 for Pugged tiles. Lugged tiles staged
at pitch>5:12 may use alternate staging method (bottom 2-tile stack shalljl�e inverted,followed by 8 tiles
high on slope,as shown below)
I'
cin ..
r �
S s
Figure 1: Alternate Staging Method
Alternatively, at roof slopes greater than these limitations, all tiles shall be;loaded onto a nominal 1"x 2"
horizontal batten to prevent slippage or damage to the underlayment
6.3.3.2 . Colphene FR GR has met the tile slippage test requirements specified in fFiSAJTRI iApril 2012(04-12)up to
a 10-tile stack to a maximum roof pitch of 5:12 for flat tiles and 6:12 for lugged tile's. At roof slopes greater
than these limitations,all tiles shall be loaded onto a nominal 1"x 2" horizontal batten to prevent slippage
or damage to the underlayment.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in orderito properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Contact the manufacturer or the named QA entity for information on plants covered under Rule 61G20-3 Q4
requirements.
i
9. QUALITY ASSURANCE ENTITY: {,
UL,LLC—.QUA9625;(314)578-3406;k.chancellor@us.ul.com
it I
-END OF EVALUATION REPORT-
Ii
I I,.
Exterior Research and Design,LLC. 11 Evaluation ReportS18010.06.09-1110
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION i FL2569-1112
Soprema,Inc. ; Revision 10:06/12/2017
I Page 7 of 7
! I
I
Florida Building Code Online j I ' Page 1 of 2
I,
amp,
I ��to k',P}���s-. 5�„�, �{t x. ,...k v�l`t r F ��.� {'� �a1 � �'i 4•' ai ,.""�'°s F..+ d�a
c
BCIS Home i Log In User Registration - Hot Topics Submit Surcharge Stats&Facts , Publications FBc Staff i BCI5 Site Map Links Search
+
I ! I
bl Product Approval
-�;.,. USER:Public User I i
Product Approval Menu>Product or Application Search>Application Lis[>Application Detail
'4
t sl FL# F12569-R12 I•
Application Type Revision
! Code Version 2014 +
I;
Application Status Approved
Comments
Archived I f
i'
Product Manufacturer Soprema,Inc. (Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville,NON-US 00000
(819)478-2400
memathieu@soprema.ca i
Authorized Signature Marc-Etienne Mathieu j t
memathieu@soprema.ca ,
Technical Representative Marc-Etienne Mathieu
Address/Phone/Email 1688 Jean-Berchmans-Michaud
Drummondville,NON-US 00000 �'I!
(819)478-2400 Ext 3327
memathieu@soprema.ca iI
�i+ I
Quality Assurance Representative Jean-Francois Cote, Ph.D.
Address/Phone/Email 1640 rue Haggarty
+
Drummondville �I;
(888)811-3145
jfcote@soprema.ca I �,
l i
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert J. M. Nieminen I;
the Evaluation Report I,
Florida License PE-59166 .
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 07/17/2020
I
Validated By John W.Knezevich,PE i
I _J Validation Checklist-Hardcopy Received
I
Certificate of Independence FL2569 R12 COI 2017 011 COI Nieminen.odf
Referenced Standard and Year(of Standard) Standard ! Year
ASTM D1970 2009
ASTM D6163 j I' 2000
ASTM D6164 2005
FM 4474 I 2004
FRSA/TRI April 2012(04-12) 2012
TAS 103 Ii 1995
TAS 110 2000
UL 1897 2004
� i• i
http:/huww.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsK'ZFEncM 10... 11/1/2017
FloridaBuilding Code Online '' Page 2 of 2
I ,
I I
Equivalence of Product Standards
Certified By I.
Sections from the Code
I i
' III
Product Approval Method Method 1 Option D i w
I '
Date Submitted 06/12/2017
i
Date Validated 06J13/2017
Date Pending FBC Approval 06/15/2017 I;I
Date Approved 08/08/2017
Date Revised 10/09/2017
I
Summary of Products
FL# Model,Number or Description
Name
2569.1 Soprema Roof Self adhering roof underlayments
Underlayments
I
Limits of Use Installation Instructions I'I
Approved for use in HVHZ:No FL2569 R12 II 2017 06 FINAL ER ISOPREMA''CA UNDERLAYMENTS FL2569-
Approved for use outside HVHZ:Yes R12.pdf
Impact Resistant:N/A Verified By: Robert Nieminen,P.E. PE.59166
Design Pressure:+N/A/-150 Created by Independent Third Party: es
Other: 1.)Refer to ER Section 5 for Evaluation Reports
Limits of Use.2.)The design pressure FL2569 R12 AE 2017 06 UNAL ER SOPREMA, CA UNDERLAYMENTS FL2569-
noted herein pertains to underlayment R12.pdf
systems used beneath adhesive-set tile Created by Independent Third Party:IYes ! '
systems.Refer to ER Section 5.6.4 for i
details.
I
Back Next '
i
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:B50-487-1824
I Ii
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement:: cc ability Statement::Refund Statement
Under Florida late,email addresses are public records.If you do not want your e-mail address releasetl in response[o a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,iplease contact 850.487.1395.'Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However'email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here. I I I
'Product Approval Accepts:
M ® Lrscf 0
i I..
Credit Card
Safe
�'a,,..-tea� =
I'
Ii•
fl I
' I
I i I
I � I
i
I
http://www.floridabuiIding.org/pr/pi_app_dtl.aspx?param=wGEVXQV tOgsKQFEnckB 10... 11/1/2017
| |
|\
!
. / .
~r^~~ORRESEARCH&DESIGN, LLC.'
rtificate of Authorization#9503/ ��s CHRISTIAN'
' 3TPEE�UN|T#15
� !��R��
| � U ��n�8��U U 8OXFORD,CT 06478
! ` (203)262-9245
EVALUATION REPORT
�
! Soprenna,Inc. EvaluaiionReport S18010.06.09-1110
164Orue Haggerty '�' { FL2569-B13
Drummondville,Qu6becJ2C5P8 Canada Date of,Issuance:06/15/2009
(819)478-2400 R�vision 10:06/12/2017
This Evaluation Report is issued under Rule 611320-3 and the applicable rules and regu lations governing the use of
construction materials in the State of Florida. The documentation submitted hasl been r'ie&iewel[l by Robert Nieminen,
P.E. for use of the Product under the Florida Iluilding Code and Florida Building COde, Residential Volume. The
produ�s described herein have been evaluated for compliance with h the Edition ��" ^ .m, o Building Code
sections noted henein � �'' " ` ,' �
. /
DESCRIPTION: SopremmaRoof 0mdenlayooentsLABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
�
CONTINUE15 COMPLIANCE: This Evaluation Report is valid until such time as the name'd prod'u'clt(s) c I hanges,the referenced
Quality Assurance documentation_changes,or provisions of..^C..^ ...^.^~..
advertising to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notifV Robert N,,ieminen, P.E. if the product
changes or the referenced i "
-Quality Assurance documentation changes. Trinityl ER,D reqqy�es a l;1omplete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinityliERD Evaluated" may be displayed in
y portion of the Evaluation Reportis —displayed,then
it1shall.be!done in its entirety.
INSPECTION: Upon request,a copy of this entire Evaluation Report shall be'provide'd to th I eiuser by the manufacturer or
its distributors and shall be available for inspection at the job site at the request6f Buildingthe � � |
_ -.
This Evaluation Report consists of pages 1 through 7.
/
! � �
Prepared by:
Thefacsimile seal appearIngwas authorized by Robert Niermnen,
Robert J.M. Nieminen,P.E.
�
| /
�^ |
_Ej—n 06/1212617.This does not serve as an electronicalIV signed
__
Florida Registration No.59166,Florida DCA ANE1983 document.Slgne�;sealed hardcopies have been t ransmitted to the
CERTIFICATION OF INDEPENDENCE:
1. TrinityIERD does not have, nor does it intend to acquire or will it acquire, a financial any c.ompanv manufacturing or
distributing products it evaluates.
2. TrinityJERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued. i iJ.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
S. This is " building`"""eva.""""". Neither, ..."w/E"" nor Robert mlem/vo� P.E. are, the Designer mRecord m,anv
project onwhich this Evaluation Report, orprevious versions thereof, islivas used for permitting or design guidance unless retained
.
specifically for that purpose.
! / /
1 /
`
/ [
i/
|
f
i
i I,r
IFFYERD
ROOFING COMPONENT(EVALUATION: I '
1. SCOPE: '
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demohstrated compliance with the
following sections of the Florida Building Code through testing in accor&nce with the following Standards.
Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard I.; i Year
j 1504.3.1 Wind Resistance FM 4474 2004
1504.3.1 Wind Uplift UL 1897 1, 2004
1507.2.4,1507.2.8, Physical Properties ASTM D1970 ' 2009
1507.2.9.2,1507.4.5.1, I P,
1507.5.3,1507.7.3
1507.11.2 Physical Properties ASTM D6163 2000
1507.11.2 Physical Properties ASTM D6164 2005
1523.6.5.2.1 Physical Properties TAS 103 ! 1995
TAS 110 Accelerated Weathering TAS 110 + l I 2000
1507.3.3 Installation Practice FRSA/TRI April 2012(04-12); 2012
3. REFERENCES:
I �
Entity Examination Reference' Date
ERD(TST6049) ASTM D1970/TAS 110 2968.05.0412 f 05/14/2004
ERD(TST6049) Physical Properties 2757.02.051 ; 02/03/2005
ERD(TST6049) ASTM D1970/TAS 110 2974.03.052 (,,j 1 05/17/2005
ERD(TST6049) Wind Resistance 2778.07.05, i 07/15/2005
ERD(TST6049) Wind Resistance 2779.11.05IR1 i 04/18/2007
ERD(TSTG049) TAS 103/TAS 110 57120.11.07-2 'i, 11/02/2007
ERD(TST6049) ASTM D1970/TAS 110 S13190.02.09-111 t r 04/01/2010
1 ERD(TST6049) ASTM D1970/TAS 110 S31370.03.10-1-R1 I,; I 04/07/2010
ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.10-R1II 09/09/2010
ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.09-R2 I I 10/05/2010
i
ERD(TST6049) ASTM D1970 S37210.11.11 11/09/2011
ERD(TST6049) ASTM D1970 S40540.02.13-1 j,' 02/19/2013
i ERD(TST6049) Physical Properties/Tensile Adhesion 543530.02.14-1 02/21/2014
ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645'02.15{" ' 02/13/2015
ERD(TST6049) Accelerated Weathering .SOPC-SC8520.14 f'� 04/17/2015
ERD(TST6049) Wind Resistance SOPC-SC14045.05.1Z R1 06/07/2017
M-D(CER1592) HVHZ Compliance 15-0508.04 I 09/24/2015
ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017
PRI(TST5878) Physical Properties SOP-064-02-01 12/03/2013
I Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 401' 05/29/2015
UL,1 LLC(QUA9625) Quality Control Service Corifirmatiol ' Exp.10/16/2017
4. ': PRODUCT DESCRIPTION:.
f 4.1 Lastobond TU HT is a self-adhering, non-woven polyester fabric surfaced, SBS(modified bitumen roof
underlayment. I
4.2 Lastobond Shield is a self-adhering, woven polyethylene surfaced,i!56S modified bitumen roof
underlayment available in two widths;36 and 45 inch.
I
4.3 RESISTO SA SMOOTH PLY 40 is a self-adhering, woven polyethylene surfal ed,SBS modified bitumen roof
underlayment;available in 3.3 ft x 65 ft rolls. ,
Exterior Research and Design,LLC. I i Evaluation Report S18010.06.09-1110
Certificate of Authorization#9503 FBC NON-HW7 EVALUATION � I� � F1.2569-1112
Soprema,Inc. j Revision 10:06/12/2017
I i Page 2 of 7
j11 ;
i
SII ER
4.4 Lastobond Shield HT is a self-adhering, woven polyethylene surfaced, hiidh temperature, SBS modified
bitumen roof underlayment. I'
i �
4.5 Lastobond Pro HT-N is aself-adhering, woven polyethylene surfaced SBS modified bitumen roof
underlayment available in two widths;36 and 45 inch.
' f•
4.6 Lastobond Pro HT-S is a self-adhering, woven polyethylene surfaced, higli temperature, SBS modified
bitumen roof underlayment. j
4.7 Lastobond 195 is a self-adhering, glass-mat reinforced, sand-s rfacedi'i SBS modified bitumen roof
i underlayment.
4.8 Lastobond Eaves Protection Sheet is a self adhering, glass-mat reinforced',•sand-'surfaced, SBS modified
bitumen roof underlayment.
i 4.9 Lastobond Eco is a self-adhering, glass-mat reinforced, sand-surfaced SBS modified bitumen roof
underlayment.
4.10 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced, film-sur'faced, SBS modified bitumen
roof underlayment.
4.11 RESISTO LB1236 is a self-adhering, glass-mat reinforced, sand-surfaced;,SBS modified bitumen roof
underlayment,with a 36-inch sheet width. I
4.12 PrimeSource Grip-Rite Eave&Valley Protector is a self-adhering,glass-mat reinforced,sand-surfaced,SBS
modified bitumen roof underlayment,with a 36-inch sheet width.
4.13 RESISTO LB1244 is a self-adhering, glass-mat reinforced, sand-surfaced;,SBS Modified bitumen roof
underlayment,with a 44-inch sheet width.
f;
4.14 Colphene FR GR is a self-adhering, fiberglass reinforced, granulelsurface'd', SBS ;modified bitumen roof
underlayment.
5. LIMITATIONS:
II,
5.1 This is a building code evaluation. Neither TrinityERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically fir that purpose
5.2 -This Evaluation Report is not for use in the HVHZ. yi ;
5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Soprema Roof Underlayments may be used with any prepared roofjcover where the product is specifically
referenced within FBC approval documents. If not listed,a request may belmade to the Authority Having
Jurisdiction for approval based on this evaluation combined with supportirig data for the prepared roof
covering.
5.5 Allowable roof covers applied atop the underlayments are follows:
TAII1::ROor COVER OPTIONS
Underla ment Asphalt Nail-On Foam-On: i i• Wood Shakes&
Y Metal Slate
Shingles Tile Tile I I Shingles
i
Lastobond TU HT Yes Yes Yes I Yes Yes Yes
See 5.5.1E h
Lastobond Shield/Pro HT-N/ yes No No No Yes Yes
RESISTO SA SMOOTH PLY 40
Lastobond Shield HT/Pro HT-S Yes No No j Yes Yes Yes
Lastobond Eaves Protection
Yes No No i N4 Yes Yes
Sheet/Lastobond 195 �
I,
I
i
Exterior Research and Design,LLC. lEvaluation Report 518010.06.09-R10
Certificate of Authorization ti9503 FBC NON-HVHZ EVALUATION
FL2569-1112
Soprema,Inc. Revision 10:06/12/2017
j Page 3 of 7
I