Loading...
HomeMy WebLinkAboutProduct Approval (4) MIAM!•QADE Zl MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.euv/economy GAF I Campus Drive Parsipanny,NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Leak Barriers and Roof Deck Protection LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA 13-1104.11 and consists of pages I through 8. The submitted documentation was reviewed by Alex Tigera. NOA No.: 14-0915.02 JAPPROVED1 1 Expiration Date: 02/21/18 Approval Date: 09/10/15 Page I of 9 ROOFING COMPONENT APPROVAL Cate¢orv: Roofing Sub-Cate¢orv: Underlayment Material: SBS/Polypropylene/Asphalt PRODUCTS DESCRIPTION: Test Product Product Dimensions Saecification Description WeatherWatch® 36"x 50' rolls ASTM D 1970 Granular surfaced modified, fiberglass reinforced, Mineral Surfaced Leak 36"x 66.7' rolls bituminous sheet material for use as a leak barrier Barrier underlayment in sloped roof assemblies. Manufacturing Designed as an ice&rain shield. Location#2,3 WeatherWatch'XT 36"x 50' rolls ASTM D 1970 Mat surfaced modified,fiberglass reinforced Mat Surfaced Leak 36"x 66.7' rolls bituminous sheet material for use as a leak barrier Barrier underlayment in sloped roof assemblies. Manufacturing Designed as an ice&rain shield. Location#3 StormGuard°1 Film 36"x 66.7' rolls ASTM D 1970 Modified,fiberglass reinforced,bituminous sheet Surfaced Leak Barrier material for use as a high temperature leak barrier Manufacturing underlayment in sloped roof assemblies. Location#2 Designed as an ice&rain shield. LibertyTM SBS Self- 39-'/8"x 66' rolls ASTM D 1970 Self-adhering SBS roof membrane. Adhering Base/Ply Sheet Manufacturing Location#2 UnderRoof"2 39 3/s"x 67.8' rolls ASTM D 1970 Self-adhering reinforced membrane of SBS Polyester-Surfaced modified asphalt with polyester surfacing for use Leak Barrier with asphalt shingle roof assemblies. Roof slopes Manufacturing of 2:12— 12:12 are acceptable as indicated by Location#1,3 local codes and manufacturer's installation instructions. UnderRoof r"HT High 39-`/s"x 61.0' rolls ASTM D 1970 Self-adhering reinforced membrane of SBS Temperature Leak modified asphalt with polyester surfacing for use Barrier as a high temperature underlayment in sloped Manufacturing metal and asphalt shingle roof assemblies. Roof Location#3 slopes of 2:12— 12:12 are acceptable as indicated by local codes and manufacturer's installation instructions. aADE COUNTY NOA No.: 14-0915.02 MIAMEL •••• • Expiration Date: 02/21/18 Approval Date: 09/10/15 Page 2 of 8 PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description Deck-Armor T11 54"x 222' rolls ASTM D 226 A UV-stabilized polypropylene breathable Premium Breathable 48"x 100' rolls Type ll underlayment. To be used for roof deck Roof Deck Protection protection as an underlayment in sloped roof Manufacturing assemblies. Location#4 Tiger PawT"Roof Deck 48"x 250' rolls ASTM D 226 A UV-stabilized polypropylene non-breathable Protection 48"x 100' rolls Type ll underlayment.To be used for roof deck protection Manufacturing as an underlayment in sloped roof assemblies. Location#5,8,9 FeltBuster"High- 48"x 250' rolls ASTM D 226 A UV-stabilized polypropylene non-breathable Traction Synthetic Type 1 underlayment.To be used for roof deck protection Roofing Felt as an underlayment in sloped roof assemblies. Manufacturing Location#10 Shingle-Mate®Roof 36"x 144' rolls ASTM D 226 Fibergass-reinforced asphalt felt underlayment.To Deck Protection Type l be used for roof deck protection as an Manufacturing underlayment in sloped roof assemblies. Location#6,7 rw►r+En�4pe cotTr NOA No.: 14-0915.02 APPROVEDExpiration Date: 02/21/18 Approval Date: 09/10/15 Page 3 of 8 MANUFACTURING LOCATION: 1. Fresno,CA 2. Mt.Vernon, 1N 3. North Branch,NJ 4. North Bay,Ontario 5. Mission,British Columbia 6. Pryor,OK 7. McGregor,TX 8. Qingdao,China 9. Charleston,SC 10. Spartanburg,SC EVIDENCE SUBMITTED: Test Aaency Test Identifier Test Name/Revort Date Intertek Testing Services NA Ltd. 3077464-01 ASTM D 1970 08/23/06 3090131 Wind Uplift and Self Sealability 08/23/06 100258583COQ-OIOA ASTM D 226 Type II 01/11/11 100673818COQ-003 ASTM D 226 Type II 06/13/13 10157289000Q-005 ASTM D 226 Type 11 04/17/14 PRI Construction Materials RGM-023-02-01 ASTM D 4798 05/16/07 Technologies,LLC. GAF-112-02-01 ASTM D 226 Type II 03/15/06 GAF-238-02-01 ASTM D 1970 03/03/10 GAF-323-02-01 ASTM D 1970 11/30/11 GAF-324-02-01 ASTM D 1970 11/30/11 GAF-325-02-01 ASTM D 1970 11/30/11 GAF-326-02-01 ASTM D 1970 11/30/11 GAF-275-02-01 ASTM D 1970 11/11/10 GAF-344-02-01 ASTM D 1970 04/23/12 GAF-339-02-01 ASTM D 226 Type I 03/14/12 ELK-311-02-01 ASTM D 1970 09/11/07 GAF-446-02-01 ASTM D 226 Type I 09/26/13 GAF-518-02-01 ASTM D 226 Type 1 06/04/14 NOA No.: 14-0915.02 QnrtaaanecouNnr Expiration Date: 02/21/18 Approval Date: 09/10/15 Page 4 of 8 APPROVED ASSEMBLIES: Deck Type 1: Wood,non-insulated Deck Description: 19/32"or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened to deck,membrane adhered. Base Sheet: Two plies of ASTM D 226 Type I or Shingle-Mate"Roof Deck Protection OR one or more plies of ASTM D 226 Type 11,Deck-Armor"Premium Breathable Roof Deck Protection,FeltBuster* High-Traction Synthetic Roofing Felt,or Tiger Pawl Roof Deck Protection with a minimum 4" side lap and a 6"end lap mechanically fastened to the deck with approved nails and tin caps 6" o.c. at the laps and four staggered rows 12" o.c. in the field of the roll. If roof is exposed to rain/snow,tape all end and side laps with approved butyl adhesive based seam/cover tape or an approved waterproof cloth duct tape(follow the tape's manufacturer's installation instructions). Always apply tape over all fasteners at the center of the roll or the end laps to help prevent rain or snow from entering at the fastneners. Membrane: One or more plies of WeatherWatch$'Mineral Surfaced Leak Barrier, WeatherWatch®XT Mat Surfaced Leak Barrier,StonnGuardO°Film Surfaced Leak Barrier,or LibertyTm SBS Self- Adhering Base/Ply Sheet membrane with a minimum 3"side lap and 6"end lap. Place the first course of membrane parallel to the eave,rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical strapping of the roof with WeatherWatch®Mineral Surfaced Leak Barrier,WeatherWatch®XT Mat Surfaced Leak Barrier, or StormGuardO Film Surfaced Leak Barrier is acceptable. Surfacing: Approved Roofing Assembly. Deck Type 1: Wood,non-insulated Deck Description: 19/32"or greater plywood or wood plank System E(2): Membrane mechanically fastened to deck. Separator Sheet: One or more plies of GAF GAFGLASO Ply 4,GAFGLAS'Flex-PlyTm 6,Rosin Paper,ASTM D 226 Type I or Type 11, Shingle-Mate®Roof Deck Protection,Deck-ArmorTM Premium Breathable Roof Deck Protection,FeltBuster°D High-Traction Synthetic Roofing Felt,or Tiger Paw"Roof Deck Protection loose laid. Membrane: One or more plies of WeatherWatch'l Mineral Surfaced Leak Barrier,WeatherWatch®XT Mat Surfaced Leak Barrier,StormGuard®Film Surfaced Leak Barrier,or LibertyTM SBS Self- Adhering Base/Ply Sheet membrane mechanically fastened with a minimum 3"side lap and a 6" end lap to deck through the separator sheet with approved nails and tin caps 6" o.c.at the laps and two staggered rows 12" o.c. in the field of the roll. Surfacing: Approved Roofing Assembly. � NOA No.: 14-0915.02 MIAMFDADECOUN� Expiration Date: 02/21/18 Approval Date: 09/10/15 Page 5 of 8 Deck Type 1: Wood,non-insulated Deck Description: 19/32° or greater plywood or wood plank System E(3): Anchor sheet mechanically fastened to deck,membrane adhered. Secondary Water Install a minimum 4"wide WeatherWatch®Mineral Surfaced Leak Barrier,WeatherWatch®XT Barrier: Mat Surfaced Leak Barrier,or StormGuard'Film Surfaced Leak Barrier membrane over the (Optional) joints of the plywood roof deck prior to installation of the base sheet.Do not overlap end or side joints. All side and end laps should be butted firmly side by side,flush with each other but not overlapped.Do not leave the WeatherWatch®Mineral Surfaced Leak Barrier,WeatherWatch® XT Mat Surfaced Leak Barrier,or StormGuardl Film Surfaced Leak Barrier membrane exposed for more than 30 days without a roof deck protection underlayment protecting the secondary water barrier. Base Sheet: Two plies of ASTM D 226 Type I or Shingle-Mate"Roof Deck Protection OR one or more plies of ASTM D 226 Type I1,Deck-ArmorTm Premium Breathable Roof Deck Protection, FeltBuster®High-Traction Synthetic Roofing Felt,or Tiger PaiW1 Roof Deck Protection with a minimum 4"side lap and a 6"end lap mechanically fastened to the deck with approved nails and tin caps 6" o.c.at the laps and four staggered rows 12" o.c. in the field of the roll. If roof is exposed to rain/snow,tape all end and side laps with approved butyl adhesive based seam/cover tape or an approved waterproof cloth duct tape(follow the tape manufacturer's installation instructions). Always apply tape over all fasteners at the center of the roll or the end laps to help prevent rain or snow from entering at the fasteners. Surfacing: Approved Roofing Assembly. Deck Type 1: Wood,non-insulated Deck Description: 19/32"or greater plywood or wood plank System E(4): Anchor sheet mechanically fastened to deck,membrane adhered. Base Sheet: Two plies of ASTM D 226 Type I or Shingle-Mate®Roof Deck Protection OR one or more plies of ASTM D 226 Type II,Deck-Armor"Premium Breathable Roof Deck Protection, FeltBuster®High-Traction Synthetic Roofing Felt,or Tiger Pawl Roof Deck Protection with a minimum 4"side lap and a 6"end lap mechanically fastened to the deck with approved nails and tin caps 6" o.c.at the laps and four staggered rows 12" o.c. in the field of the roll. If roof is exposed to rain/snow,tape all end and side laps with approved butyl adhesive based seam/cover tape or an approved waterproof cloth duct tape(follow the tape's manufacturer's installation instructions). Always apply tape over all fasteners at the center of the roll or the end laps to help prevent rain or snow from entering at the fastneners. Membrane: One or more plies of StormGuardl Film Surfaced Leak Barrier,UnderRoof 2 Polyester- Surfaced Leak Barrier or UnderRoofrm HT High Temperature Leak Barrier membrane with a minimum 4"side lap and 6"end lap. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Surfacing: Approved for Metal roofing(StormGuard®Film Surfaced Leak Barrier,or UnderRoofrm HT High Temperature Leak Barrier),Slate,and Asphalt Shingle assemblies. NOA No.: 14-0915.02 I�AMICOUWNTY Expiration Date: 02/21/18 • Approval Date: 09/10/15 Page 6 of 8 LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. WeatherWatch® Mineral Surfaced Leak Barrier, WeatherWatch® XT Mat Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self-Adhering Base/Ply Sheet, UnderRoofrM HT High Temperature Leak Barrier, Shingle-Mate® Roof Deck Protection, Deck-Armor" Premium Breathable Roof Deck Protection, FeltBuster®High-Traction Synthetic Roofing Felt,and Tiger Paw'Roof Deck Protection shall not be used as roof tile underlayment. 3. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. WeatherWatch`a Mineral Surfaced Leak Barrier, WeatherWatch®XT Mat Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier. LibertyTM SBS Self-Adhering Base/Ply Sheet, UnderRoof 2 Polyester-Surfaced Leak Barrier, UnderRoofr' HT High Temperature Leak Barrier, Shingle-Mate" Roof Deck Protection, Deck-Armor'" Premium Breathable Roof Deck Protection, FeltBuster® High-Traction Synthetic Roofing Felt, and Tiger PawTm Roof Deck Protection shall be installed in strict compliance with applicable Building Code. 4. WeatherWatch' Mineral Surfaced Leak Barrier, WeatherWatch® XT Mat Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self-Adhering Base/Ply Sheet, UnderRoofrM 2 Polyester-Surfaced Leak Barrier, UnderRoofrM HT High Temperature Leak Barrier, Shingle-Mate® Roof Deck Protection, Deck- ArmorTM Premium Breathable Roof Deck Protection, FeltBuster' High-Traction Synthetic Roofing Felt,and Tiger Paw' Roof Deck Protection membranes shall be applied to a smooth, clean and dry surface with deck free of irregularities. 5. WeatherWatch® Mineral Surfaced Leak Barrier, WeatherWatch' XT Mat Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self-Adhering Base/Ply Sheet, UnderRoof M 2 Polyester-Surfaced Leak Barrier, UnderRoof" HT High Temperature Leak Barrier, Shingle-Mate® Roof Deck Protection, Deck- Armot" Premium Breathable Roof Deck Protection,FeltBuster'High-Traction Synthetic Roofing Felt,and Tiger Paw'Roof Deck Protection membranes shall not be applied over an existing roof membrane. 6. WeatherWatch® Mineral Surfaced Leak Barrier, WeatherWatch® XT Mat Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self-Adhering Base/Ply Sheet, UnderRoofrM 2 Polyester-Surfaced Leak Barrier, UnderRoofr"' HT High Temperature Leak Barrier, Shingle-Mate`s Roof Deck Protection, Deck- Armor" Premium Breathable Roof Deck Protection, FeltBuster' High-Traction Synthetic Roofing Felt,and Tiger Paw'Roof Deck Protection shall not be left exposed as a temporary roof for longer than 30 days of application. 7. WeatherWatch00 Mineral Surfaced Leak Barrier, WeatherWatch® XT Mat Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self-Adhering Base/Ply Sheet, UnderRoofm 2 Polyester-Surfaced Leak Barrier, UnderRoofr' HT High Temperature Leak Barrier, Shingle-Mate' Roof Deck Protection, Deck- Armor' Premium Breathable Roof Deck Protection, FeltBuster®High-Traction Synthetic Roofing Felt,and Tiger Paw' Roof Deck Protection may be used with any approved roof covering Notice of Acceptance listing WeatherWatch Mineral Surfaced Leak Barrier, WeatherWatch' XT Mat Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self-Adhering Base/Ply Sheet, UnderRoot' 2 Polyester-Surfaced Leak Barrier, UnderRoofl HT High Temperature Leak Barrier, Shingle-Mate® Roof Deck Protection, Deck- ArmorTM Premium Breathable Roof Deck Protection, FeltBuster®High-Traction Synthetic Roofing Felt, and Tiger Paw'Roof Deck Protection as a component part of an assembly in the Notice of Acceptance. If WeatherWatch® Mineral Surfaced Leak Barrier, WeatherWatch'XT Mat Surfaced Leak Barrier, StormGuard®Film Surfaced Leak Barrier, LibertyTM SBS Self-Adhering Base/Ply Sheet, UnderRoofr"' 2 Polyester-Surfaced Leak Barrier, UnderRoofr' HT High Temperature Leak Barrier, Shingle-Mate®Roof Deck Protection,Deck-Armor' Premium Breathable Roof Deck Protection, FeltBuster' High-Traction Synthetic Roofing Felt and Tiger Paw' Roof Deck Protection are not listed; a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami-Dade County Product Control Department for approval provided that appropriate documentation is provided to detail NOA No.: 14-0915.02 MMMADEcOUNTY Expiration Date: 02/21/18 Approval Date: 09/10/15 Page 7 of 8 LIMITATIONS: compatibility of the products,wind uplift resistance, and fire testing results. 8. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. Install when temperatures are 45° F and rising. 9. When applying the membrane in the valley,start at the low point and work to the high point,rolling the membrane from the center outward in both directions. 10. Roll or broom the entire membrane surface so as to have 100%contact with the surface,giving special attention to overlap areas. 11. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 12. Wherever the adhesive back of UnderRoofr" 2 Polyester-Surfaced Leak Barrier, or UnderRoof" HT High Temperature Leak Barrier comes in contact with polyester surfacing such as end laps, penetrations, and flashing material, it must be set in a 1/8"troweling of an approved ASTM D 4586 Type I roofing cement. 13. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 14. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,city and state of manufacturing facility, and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MIAMI-DADE COUNTY ��UUMIYJ4171 END OF THIS ACCEPTANCE NOA No.: 14-0915.02 APPROVED Expiration Date: 0221/18 Approval Date: 09/10/15 Page 8 of 8