Loading...
HomeMy WebLinkAboutBuilding Permit Application ALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED /� Date: 12/19/17 Permit Number:012 0 509 .Ain"1111111lb— , Building Permit Application DEC 19 2017 Planning and Development Services PERfM171I�G Building and Code Regulation Division St. Lucie County, ::L 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772)462-1553 Fax: (772)462-1578 Commercial X Residential PERMIT APPLICATION FOR: Mechanical PROPOSED IMPROVEMENT LOCATION: Address: 7600 S OCEAN DRIVE Legal Description: Property Tax ID#: 3522-312-0003-000-1 Lot No. Site Plan Name: Block No. Project Name: Setbacks Front Back: Right Side: Left Side: DETAILED DESCRIPTION OF WORK: LIKE FOR LIKE CHANGEOUT (4) EXHAUST FANS ADDITIONAL DOCUMENTS ATTACHED CONSTRUCTION INFORMATION: Additional work to be nertormedunder this permit—check all appy: HVAC LI Gas Tank []Gas Piping Shutters a Windows/Doors ❑Electric ❑ Plumbing Sprinklers ❑Generator Roof Roof pitch Total Sq. Ft of Construction: SFt. of First Floor: Cost of Construction:$ 55,383.00 Utilities:Sewer E]Septic Building Height: OWNER/LESSEE: CONTRACTOR: Name ST LUCIE COUNTY Name: CHRIS LANGEL Address:2300 VIRGINIA AVENUE Company: SEACOAST A/C City: FT PIERCE State:FL Address: 3108 INDUSTRIAL 31 st STREET Zip Code: 34982 Fax: City: FT PIERCE State:FL Phone No. Zip Code: 34946 Fax: 772-466-3053 E-Mail: Phone No. 772-466-2400 Fill in fee simple Title Holder on next page( if different E-Mail: DANISEACOASTAIR@AOL.COM from the Owner listed above) State or County License: CMC035421 If value of construction is$2500 or more,a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: DESIGNER/ENGINEER: _ Not Applicable MORTGAGE COMPANY: _ Not Applicable Name: Name: Address: Address: City: State: City: State: Zip: Phone: Zip: Phone: FEE SIMPLE TITLE HOLDER: _Not Applicable BONDING COMPANY: Not Applicable Name: Name: Address: Address: City: City: Zip: Phone: Zip: Phone: I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize thepermit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure.Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans,the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures,swimming pools,fences,walls,signs,screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorney before commencing work or recording our Notice of Commencement. s Signatur of Owner/Lessee/Contractor as Agent for Owner Signature of Contractor/License Holder STATE OF FLORIDA STATE OF FLORIDA COUNTY OF ST LUCIE COUNTY OF ST LUCIE The 7fing ins e t was a knowl d e efore me The oing ins ent was ac nowledged fore me thisday of 20 Uby this day of 0 Vby CIHRIS LANGEL CHRIS LANGEL IN a of person acknowledging) (Na of person acknowledging) 1AI uIdL:, (Signature of Notary Public-State of Florida) ignature of Notary Public-State of Florida) Personally Known x OR Produced Identification Personally Known x OR Produced Identification Type of Identification Produced ,uCType of Identification Produced Commission No. FF96 1,1,E�' `SFg614"' Commission No. FF961459 (Seal) .• MY COM Feuti&"' EMAN FF961459 Revised 07/1 •/ r `!;: Iss1oN ,,59 My COMM 16.2020 IIAW EXPIRE'148INT" Irk S FebNery r di 3 REVIEWS FRONT ZONING SUPERVISOR PLANS 4tyN SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE COMPLETE INITIALS EEC H iV LJGREENHECK DEC 119 2017 Printed Date: 9/21/2017 Job: SEVERN TRENT 09-21-17 Building Value in Air. PERDdITTING Mark: Mark 1 St. Lucie County, FL Model: RCE3-42-623-C30 Model: RCE3-42-623-C30 Propeller Hooded Roof Direct Drive Exhaust Fan 86.00 99.00 24.00 Dimensional 45.00 _- - Quantity 2 �zso 1 Weight w/o Acc's(lb) 667 i Weight w/Acc's(lb) 699 52.25—1 L52.25-1 Max T Motor Frame Size 256 Optional Damper(in.) 42 x 42 Roof Opening(in.) 44.5 x 44.5 Performance 1.2 4 Requested Volume(CFM) 15,000 Actual Volume(CFM) 16,268 External SP(in.wg) 0.25 -..60 R ---- Total SP(in.wg) 0.382 0.9 RAM -- 3 Fan RPM 860 --- ---------------- Operating Power(hp) 3.02 m a Elevation(ft) 10 Airstream Temp.(F) 70 N O Air Density(Ib/ft3) 0.075 d \ Tip Speed(ft/min) 9,456 a c ` Static Eff.(%) 32 0.3 �n m � oQ Motor 0.0 0 Motor Mounted Yes 0 3 6 9 12 15 18 21 24 Size(hp) 3 Volume(CFM)x 1,000 Voltage/Cycle/Phase 460/60/3 Enclosure TEFC Operating Bhp point External SP 0.25 in.wg Motor RPM 860 O Operating point at Total External SP Direct Drive RPM Adjustment 0.057 in.wg • Operating point at External SP Damper 0.075 in.wg Windings 1 Fan curve Total SP 0.382 in.wg -System curve ------- Brake horsepower curve Notes: All dimensions shown are in units of in. 'Please consult factory for actual motor amp draw C Sound Power by Octave Band LwA-A weighted sound power level,based on ANSI S1.4 ago dBA-A weighted sound pressure level,based on 11.5 d8 iffne t Sound62.5 125 250 500 1000 2000 4000 8000 LwA dBA Sones attenuation per Octave band at 5 ft-dBA levels are not foUnD Data licensed by AMCA International w Inlet 87 87 90 88 84 84 80 78 91 80 32 Sones-calculated using AMCA 301 at 5 ft pip /Evo1lw�IlOf CAPS 4.24.1420 Page 1 of 10 /21/2017 LJGREENHECKJob: SEVERN TRENT�09-21 17 Building Value in Air. Mark: Mark 1 Model: RCE3-42-623-C30 Model: RCE3-42-623-C30 Propeller Hooded Roof Direct Drive Exhaust Fan Standard Construction Features: -Base and hoods of galvanized steel-Drive frames and fan panels of fabricated steel-Wire mesh birdscreens-Ball bearing motors-Cast aluminum airfoil blade propeller-Corrosion resistant fasteners-Due to shipping size limitations,hoods for fans sizes 48 and larger will be shipped knocked down.Hood assembly requires no special tools or training.Complete illustrated assembly and installation instructions are packed with each fan. Selected Options & Accessories: Energy Efficient Motor-meets NEMA Table 12-11 UL/cUL 705 Listed-"Power Ventilators" Switch,NEMA-1,Toggle,Shipped with Unit Junction Box Mounted&Wired High Wind Rated(+/-130 PSF Rating) Texas Department of Insurance Product Evaluation RV-70 Florida Product Approval#FL12917.1 &Miami-Dade NOA#16-0209.03 Cast Aluminum Propeller Galvanized Construction Damper Shipped Loose,WD-100-PB-42X42,Gravity Operated,Not Coated Unit Warranty: 1 Yr(Standard) CAPS 4.24.1420 Page 2 of 10 LHGREENHECKPrinted Date: 9/21/2017 Job: SEVERN TRENT 09-21-17 Building Value in Air. Mark: Mark 1 Model: RCE3-42-623-C30 Assembly Drawing Type: Propeller Hooded Roof Direct Drive Exhaust Fan 86.00 -- - 99.00 - _ I 24.00 45.00 r2.50 2.50 L52.25 L52.25— Notes: All dimensions shown are in units of in.. CAPS 4.24.1420 Page 3 of 10 Printed Date: 9/21/2017 •GREENHECK Job: SEVERN TRENT 09-21-17 Building Value in Air. Mark: Mark 1 Model: RCE3-42-623-C30 Horizontal Mount Exhaust Damper Model: WD-100 Standard Construction Features: - Model WD-100 is a horizontal mount exhaust damper(air flow up) and is constructed of 18 ga galvanized steel with pre- punched mounting holes- Damper blades are 0.025 in. roll formed aluminum with vinyl seals on the closing edge, and spring assisted for ease of opening-Steel axles are 0.188 in. diameter zinc plated mounted in nylon bushings-Synthetic axle bearings 42 42 DAMPER TYP. SECTION VIEW CONSULT FACTORY FOR ACTUATOR POSITION Notes:All dimensions shown are in units of in. Width And height furnished approximately 0.125 in.undersize CAPS 4.24.1420 Page 4 of 10 LMGREENHECK Printed Date: 9/21/2017 Job: SEVERN TRENT 09-21-17 Building Value in Air. Mark: Mark 1 Model: RCE3-42-623-C30 AMCA amca WORLDWIDE OERTMED RATIAGS sounD iiinnD AIR i r•ORfr CE AMCA Licensed for Sound and Air Performance Without Appurtenances (Accessories). Power rating (BHP/kW)does not include transmission losses. Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP/kW)does not include transmission losses. Performance ratings include the effects of birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: free inlet hemispherical sone levels. dBA levels are not licensed by AMCA International. The AMCA Certified Ratings Seal applies to sone ratings only. The AMCA licensed air and/or sound performance data has been modified for installation, appurtenances or accessories, etc. not included in the certified data. The modified performance is not AMCA licensed but is provided to aid in selection and applications of the product. CAPS 4.24.1420 Page 5 of 10