HomeMy WebLinkAboutInspection Docs dFE` APPLICATION #:A:P1292016
STATE OF' FLORIDAPERMIT #:'J6-SF-1765259
' DEPARTMENT Olv, HEALTH
c ' ONS:ITE SEWAGE TREATMENT AND DISPOSAL SYSTEM DOCUMENT #;F11116853
CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE p=, :05/24/2017
0.
FEE PAID•65.0
RECEIPT #:56-PID-324800:5
APPLICANT: :!Missionary Flights..anci Service Ine
AGENT: South Florida Landcleaang Inc
PROPERTY ADDRESS. 3363 Hamtrond Rd Fart Pierce, FL 34946
LOT: BLOCK:
SUBDIVISION: ID#: 1430-341-0002-000-3
CHECKED [X] ITEMS: ARE NOT. IN COMPLIANCE WITH -STATUTE OR RULE AND MUST BE CORRECTED,:
TANK INSTALLATION SETBACKS
[ ] [011 TANK SIZE [1] '[2] [ I [271 SURFACE WATER FT
[ 3 [02] TANK MATERIAL COnGre.te. [ 3 [L81 DITCHES FT
[ 1 [03] OUTLET DEVICE [ ] [291 PRIVATE WELLS FT
[. ] [041 MULTI-CHAMBERED [ Y / N ] L ] [3Q] PUBLIC WELLS FT
[ ] [051 OUTLET FILTER [ ] [31.] IRRIGATION WELLS FT
[ ]_ [06] LEGEND 1, 2,. [ ] [32] POTABLE WATER FT
[ 1 [07] WATEERTIGHT [ ] [33.] BUILDINGFOUNDATIONS FT
[ 1 [08] LEVEL [ ] [34] PROPERTY .LINES FT
[ ] [09] DEPTH TO LID [" 1 [35] OTHER FT
DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM
[ ] [101 AREA [11. [2] SQFT [ ] [36] DRAINFIELD COVER
[ ]. [.11] DISTRIBUTION BOX HEADER [ 3 [371 SHOULDERS
[ ] [12] NUMBER OF DRAINLINES 1.. 2, [ 3 [38] SLOPES
[ ] [13] DRAINLINE SEPARATION [ 3 [39] STABILIZATION
[ ] [1.4] DRAINLINE SLOPE
I 3. [15.] DEPTH 'OF COVER.
ADDITIONAL INFORMATION
[ ] [16] ELEVATION [ ABOVE / BELOW IBM [ I 1401 UNOBSTRUCTED. AREA
[
I. [17] SYSTEM LOCATION [ ] [41] STOP"MTER RUNOFF
[ 3 [18] DOSING PUMPS [: ] [421 ALARMS
[ ] t191 AGGREGATE SIZE [ ] [43] MAINTENANCE AGREEMENT
[20]. AGGREGATE EXCESSIVE FINES [ ] [4:4] BUILDING AREA
[ 1 [211 AGGREGATE DEPTH [ ] [45] LOCATION CONFORMS WITH SITE PLAN
FILL / EXCAVATION MATERIAL I ] [461 FINAL SITE GRADING
[ ] [221 FILL AMOUNT 1 ] [4:7] CONTRACTOR
1. [23] FILL MEXTURE I 3 1483 .OTHER
[ 1 1241 EXCAVATION DEPTH ABANDONMENT
[ ] [25] AREA REPLACED [ ] [49] TANK PUMPED 05/25/2017
[ ] [26] REPLACEMENT MATERIAL [ ] [50`] TANK CRUSHED 6 FILLED 05/25/2017
Comments:- Commentst are on.page 2.
CONSTRUCTIONI APPROVED St.Lucie CHD DATE: 05/25/2017
DISAPPROVED ].° Environmental Specialist t4rian J Ingram(ENVIRONMENTAL HEALTH)
FINAL SYSTEM I .APPROVED f DISAPPROVED .]':. ,
St,Lucie CHD DATE:425r, 7
Environmental Specialispon Brian J Ingram(ENVIRONMENTAL HEALTH),
(Explanation of Vidl.at.�ona on foiSowing page)
DH 4016, 0_8/09 (Obsoletes all previous editions which may not .be used)
Incorporated: 64E-6.003., FAC 4ge -1 of 3
EH-Database v 1,0A AP1292016 EID1765269
�I
or z' APPLICATION #:AP1.292016
STATE OF FLORIDAPERMIT #:56-SF-1765259
DEPARTMENT Or HEALTH..
. _ DOCUMENT #:F11.115853 .
ONSITE SEWAGE TREAMONT AND DISPOSAL. SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID 05124/2017
• '. .6:5:00
FEE PAID.,. .
RECEIPT #:5:6-PID-3248005
Violation Number Comme
Comments
Tank pumped and abandoned-properly
No violations. Abandonment approved,Contractor and building department emailed final approval.
DH 4016, 08/09 (Obsoletes all .previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 2.o£ 3
EH Database v 1.0.1 AP1292016 EID1765259
Planning&Development Services ASBESTOS NOTICE
Building&Code Regulation Division
2300 Virginia Avenue
Fort Pierce,FL. 34982
Phone:(772)462-2172 Fax:(772)462-6443
Asbestos Notice to Contractor
December 21, 2017
SOUTH FLORIDA LAND CLEARING INC
COLIN M HALL
15701 ORANGE AVENUE
FORT PIERCE, FL 34945
RE: Building Permit Number 1705-0583
It is your responsibility to comply with the provisions of Section 469.003, Florida Statutes and to notify the Department
of Environmental Protection of any intentions to remove asbestos when applicable in accordance with state and federal
law.
Signature
/Z/Z-t , 7
Dale
12/21/2017 1:38:11 PM