HomeMy WebLinkAboutproduct approval J
I l
i
ALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
I Y�
Date: " Permit Number:nia- U`p90
Building Permit Application
Planning and Development Services
I
Building and Code Regulation Division
2300 Virginia Avenue,Fort Pierce FL 34982 h,
Phone: (772)462-1553 Fax:(772)462-1578 Commercial i. Residential X
PERMIT APPLICATION FOR: Roof
PRE3POSED IMPROVEMENT LOCATIdN$ . _ ..a
Address: 2856 EAGLES NEST WAY PORT ST LUCIE FL
II I,
Legal Description: EAGLES RETREAT AT SAVANNA-CLUB PHASE 2 (PB 43-21) BLK 62 LOT
26 (OR 2116-208)
Property Tax ID#: 2430-502-0054-000-1 it I -Lot No.26
Site Plan Name: I Block No. 62
Project Name:
Setbacks Front Back: Right Side: Left Side I`
1 I i,
REMOVE ALL ROOF TO BARE WOOD. INSPECT SHEETING NAILS . RENAIL TO CURRENT
CODES'IF APPLICABLE. INSTAL 30LB UNDERLAYMENT
iNSTALL SHINGLES
• i
GO�NSTRC�CTION INFORMATION � � � ��� g �s �< ��
Additional
or to e performedunder this t—checka
Gas PiShutt I i idows/DoorsHVAC Gas Tank Wi •
11
M
Electric 0 Plumbing Sprinklers Generator MJ Roof 3/12 Roof pitch
1
- Total Sq. Ft of Construction: 2000 S . Ft.of First Floor!
I
Cost of Construction:S 5500 Utilities: Sewer RIS eptic 1!Building Height: 1 STORY
OWNER/LESSEE 3 3 CONTRACTOR _=s ,t
.
r _
Name ROBERT A FERRAGINE Name: MICHAEL WILLIAMS
Address:2856 EAGLES NEST WAY Company: FAITHFUL ROOFERS LLC
City: PORT. ST LUCIE state:FL Address: 712 SW GENLRAL PATTON TERR
Zip Code: 34981 Fax: City: PORT ST LUCIE state: FL
Phone Ivo.7726340610 zip Code: 34953 1'.° Fax:
E-Mail: Phone No. 772 634 0.610
Fill in fee simple Title Holder on next page(if different E-Mail: MICHAEL@FAITHFULROOFERS.COM
from the Owner listed 'above) State or County License: CM 331265
I,.
If value of construction is$2500 or more,a RECORDED Notice of Commencement is required. j
' J I
I
I
� f
I
.SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION r1 '
DESIGNER/ENGINEER: _Not Applicable MORTGAGE COMPANY: _Not Applicable
Name: Name:
Address: Address: I'
City: State: City: I State:
Zip: Phone Zip: Phone-.
i°
FEE SIMPLE TITLE HOLDER: _Not Applicable BONDING COMPANY: I Not Applicable
Name: Name:
Address: Address:
City: City: I
Zip: Phone: Zip: Phone:
� I
OWNER/CONTRACTOR AFFIDVIT:Application is hereby made to obtain a permit io do the work and installation as indicated.
I certify that no work or installation has commenced prior to the issuance of a permit.
St.Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules,bylaws or and covenants:that may restrict or prohibit such
structure.Please consult with your Home Owners Association and review your deed for ainy restrictions which may apply.
In consideration of the granting of this requested permit,I do hereby agree that 1 will,in all respects,perform the work
in accordance with the approved plans,the Florida Building Codes and St.Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review:room additions,
accessory structures,swimming pools,fences,walls,signs,screen rooms and accessory uses to another non-residential use
WARNING TO OWNER:Your failure to Record a Notice of Commencement may result in your paying twice for
improvements to your property.A Notice of Commencement must be recorded and posted on the jobsite
before the first inspection. If you intend to obtain financing,consult with lender or an attorney before
commencing work or recording our Notice of Commencement.d24
!
_ I I
Signature of Owner/ essee/ ontractor as Agent for Owner Signature of Contractor/License Wolder
STATE OF FLORID STATE OF FLORIDA
COUNTY OF COUNTY OF—
T e
FTe forgoing instr�nent was acknowledged before me The foing instru ent was iacknowledged before me
thisa ` day of N 202 by this day of I 201�1 by
Name of person making statement Name of person making statement
Personally Known OR Produced Identification Personally Known OR'Produced Identification
-14
Type of Identification Type of Identification;)
Produced Produced
i
i
(An re of Notary Public-State Florida) (Signature of Notary'Public--State o orida)
Commission No. Co. mission No. (Seal)
"o LASHAHNA INGRAM
I ..d..k.':Qi..at .1__-..moi..-✓..a.=.F'-..��.;F"*r. ''
Notary Public State of Flo ida LASHAHNA INGRAM
4 ,,,Illllr„
+ - .Expires Dec 20,` 018 e�iea°"�s'% p„ , star orida
commission#FF 177`49 =i �` ` '
ry 0 m. _xpires Dec 20,201
REVIEWS FRONT °% , iN%nded h&l YERVISMI` NS VEGETATI T� „mss>i .
COUNT -REVIEVf/`'" W REVIEW '; F /IFuvi ed thrai�h NuIVlLry Assn
DATE
RECEIVED
DATE
COMPLETED
Rev.8/2/17
i
i
I
j
E° r"MINITY ERD
Enti Examination Reference Date
UL(TST 1740) ASTM D3161,D3462 09CA10592 03/26/2009
UL(TST 1740) ASTM D3161,D3462 09CA06856 05/15/2009
UL(TST 1740) ASTM D3161,D7158,D3462 09NK06647 I I 08/01/2009
UL(TST 1740) ASTM D3161,D7158,D3462 09CA27281 I 08/27/2009
UL(TST 1740) ASTM D3161,D7158,D3462 IOCA35554 03/05/2010
UL(TST 1740) ASTM D3161,D7158,D3462 IOCA13686 05/15/2010
UL(TST 1740) ASTM D3462 IOCA07264 I 05/27/2010
UL(TST 1740) ASTM D3462 IOCA11953 10/29/2010
UL(TST 1740) ASTM D3161,D7158,D3462 IONK11951 10/30/2010
UL(TST 1740) ASTM D3161,D7158,D3462 i IONK12070 11/04/2010
UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 01/30/2010
UL(TST 1740) ASTM D3161,D7158,D3462 IOCA53934 03/31/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48924 I 10/22/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA47919 12/03/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48408 12/08/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48725 I 12/09/2011
UL,LLC.(TST 9628) ASTM D3462 12CA34891 10/12/2012
UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 12CA58151 02/15/2013
UL,LLC.(TST 9628) ASTM D3161 12CA38083 02/26/2013
UL,LLC.(TST 9628) ASTM D3161 13CA32332 06/18/2013
UL,LLC.(TST 9628) ASTM D3161 13CA37934 08/02/2013
UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4786875675 07/17/2015
UL,U.C.(TST 9628) ASTM D3161,D7158,D3462 4787434542 05/17/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,!R21,Mobile,AL 12/28/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Myerstown,IPA 02/23/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report;R21,Tuscaloosa,AL 02/26/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Michigan Cty,IN 03/02/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,;R21,Shafter,CA 02/18/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Savannah,GA 02/24/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report R21,Minneapolis,MN 02/09/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report;1121,MtlVernon,'IN 02/09/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,1R21,Baltimore,MD 03/01/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tampa,FL 02/29/2016
j UL,LLC.(QUA 9625) Quality Control Inspection Report)R21,Dallas,TX 02/17/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report;R21,Ennis,TX I 02/03/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,1121,Foritana,CA! 03/03/2016
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Marquis® WeatherMax®, Royal Sovereign® and Sentinel® are a fiberglass reinforced 3-tab asphalt roof
shingles. �I
4.1.2 Camelot®, Camelot® Il, Fortitude"", GlenwoodTM, Grand Canyon®, Grand Sequoia®, Grand Sequoia® IR,
Grand Sequoia® ArmorShield'", Monaco®, Sienna®, Timberline® American ' Harvest®, Timberline®
ArmorShieldm II,Timberline® Natural Shadow"Timberline HD®,Timberline®Cool Series®,Timberline Ultra
HD®and Woodland®are fiberglass reinforced,laminated asphalt roof shingles.
4.1.3 Slateline®is a fiberglass reinforced 5-tab asphalt roof shingle.
4.2 Hip&Ridge Shingles:
4.2.1 Seal-A-Ridge® Ridge Cap Shingles, Seal-A-Ridge® IR Impact-Resistant Ridge Cap;Shingles, Seal-A-Ridge®
ArmorShielcl 'Ridge Cap Shingles and Timbertex®Premium Ridge Cap Shingles are fiberglass reinforced,hip
and ridge asphalt roof shingles.
I
• i
Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-R21
CertITICate of Authorization#9503 FI-10124-1119
Revision 21:08/26/2016
I Page 3 of 6
TRINITY ERD
4.3 Accessory Starter Strips: i
4.3.1 Pro-Start®Eave/Rake Starter Strip Shingles and WeatherBlockerTM'Premium Eave/Rake Starter Strip Shingles
are starter strips for asphalt roof shingles.
4.3.2 QuickStart® Peel & Stick Starter Roll is a is a mineral-surfaced, ifiberglass-reinforced, self-adhering SBS
modified bitumen starter strip, nominal 9-inch x 33 ft roll,for use with asphalt shingles with exposure of 6-
inch or less.
4.3.3 StarterMatch'°° Sharter Strip Shingles are color-coordinated starter strips fon use with Grand Canyon® and
Grand Sequoia® series asphalt shingles. StarterMatchTM' are installed as,the second starter for Grand
I Canyon®and Grand Sequoia®series installations.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Niemi'nen, P:E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.;
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to curre i t Approved Roofing Materials
jDirectory for fire ratings of this product.
5.4 wnd Classification:
5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicatingithe shingles are acceptable for
use in all wind zones up to Vasd=150 mph(V„k=194 mph). Refer to Section 6 for installation requirements
to meet this wind rating.
5.4.2 The GAF hip&ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for use in all wind zones up to
Vasa=150 mph(V„it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies only to exposure category B for C, as,defined in FBC 1609.4.3, and a
mean,roof height of 60 feet or less. Calculations by a qualified design,,professional are required for
conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C.Rule 61G20-3.
I '
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval,or be
Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3.
i
6.2 Starter Shingles or Starter Strip:
6.2.1 Installation of Pro-Start Eave/Rake Starter Strip Shingles, WeatherBlocker Premium Eave/Rake Starter Strip
Shingles and QuickStart Peel&Stick Starter Roll shall comply with the GAF current published instructions.
6.3 Asphalt Shingles: f j
i
6.3.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using
minimum four (4) nails per shingle in accordance with FBC Sections 1507:2 or R905.2, with the following
exceptions:
➢ Camelot,Camelot II,Grand Canyon,Grand Sequoia,Grand Sequoia IR,'Grand Sequoia ArmorShield,and
Woodland require minimum five(5)nails per shingle.
➢ Slateline requires minimum six(6)nails per shingle.
Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-R21
Certificate of Authorization 1!9503 FL10124-R19
Revision 21:08/26/2016
Page 4 of 6
I
I
I
I
I
J '
ii
` TRINITY ERD
'6.3.2 Fasteners shall be in accordance with manufacturer's published req irements,but not less than FBC 1507.2.6
or R905.2.5. Staples are not permitted.
6.3.3 Where the roof slope exceeds•21 units vertical in 12 units horizontal, special methods of fastening are
required. Contact the shingle manufacturer for details.
j 6.4 Hip&Ridge Shingles:
I
6.4.1 Installation of Seal-A-Ridge Ridge Cap Shingles,Seal-A-Ridge IR Impact-Resistant Ridge Cap Shingles and Seal-
A-Ridge ArmorShield Ridge Cap Shingles shall comply with the manufacturei's current published instructions
with a minimum two(2)nails,minimum 3/8-inch head diameter,per shingle and nominal 0.25-inch diameter
beads of Henkel"Loctite PL S30 Roof&Flashing Sealant".
11.5" Sealant
1° (292 mm) 1" Sellante
(25 mm) (25 rn Enduit d 6lancheit6
I ? I
1
(305 mm)
Nail
Clavo
6 5/8'-7 5/8' Clouer
(168-1914 mm) j
1 I
i
12'
(305 mm)
6.4.2 Installation of Timbertex Premium Ridge Cap Shingles shall comply with the manufacturer's current
published instructions with a minimum two (2) nails, minimum 3/8-inch Bead diameter, per shingle and
beads of Sonneborn NPI Gun Grade Polyurethane Sealant or Henkel PL Roofing and.Flashing Sealant.
1�(2a`tmn3 1^^ / Sollanlq
(23 minis25 mnyncluiE al'dtandie tm
Mai
j 4.aLicrsr
it jTl./
I
to 2-V mrn;
i (305 tttin)
6.4.3 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
' I
, I
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-1121
Certificate ojAutharization#9503 � FL10124-R39
Revision 21:08/26/2016
j Page 5 of 6
I
I
I I I
j :TRINITY[ERD
7. LABELING: f
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the requir Id classifications detailed in FBC
Table 1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(847)664-3281
END OF EVALUATION REPORT-
I
I
I
I
I
I
� I
I
I
I I
i
I
� I
II I
I i
i I
f ,
i
I
I
Exterior Research and Design,U.C. Evaluation Report 01506.01.08-1121
Certificate of Authorization#9503 F1.30124-1119
Revision 21:08/26/2016
Page 6 of 6