HomeMy WebLinkAboutProduct Approval 11/2/2017 Florida Building Code Online
Business • Professional
rg wpm=
BCIS Home ; Log In i User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff SCIS Site Map Links i Search
Florida
Product Approval pr 4
USER:Public User
- i- 7 i P
Product Approval Menu>Product or Application Search>Application List>Application Detail
• FL# FL10674-1112
DEC 2 9 2017
Application Type Revision
Code Version 2014 BY;
Application Status Approved
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
Comments FILE
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo,OH 43659
(419)376-8360
mel.sancrant@owenscornig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J.M. Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 05/16/2020
Validated By John W. Knezevich, PE
" Validation Checklist-Hardcopy Received
Certificate of Independence FL10674 R12 COI 2016 01 COI Nieminen.Ddf
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2009
ASTM D3462 2009
ASTM D7158 2008
Equivalence of Product Standards
Certified By
hftps://fioridabui[ding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5Vp/o2boQT%2b6w7ahRegICQ8ucR6ixEA65bxB8ctyag%3d%3d 1/2
11/2/2017 Florida Building Code Online
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 04/18/2016
Date Validated 04/19/2016
Date Pending FBC Approval 04/20/2016
Date Approved 06/08/2016
Date Revised 10/10/2017
Summary of Products
FL# Model, Number or Name Description
10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge shingles I
Shingles and Starters
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL10674 R12 II 2016 04 FINAL ER OC ASPHALT j
Approved for use outside HVHZ:Yes j SHINGLES FL10674-R12.Ddf
Impact Resistant: N/A Verified By: Robert 3. M. Nieminen PE-59166
Design Pressure: N/A Created by Independent Third Party: Yes
Other: Refer to ER,Section 5. Evaluation Reports
FL10674 R12 AE 2016 04 FINAL ER OC ASPHALT
SHINGLES FL10674-R12.Ddf
Created by Independent Third Party: Yes
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida. ::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395. 'Pursuant to Section
455.275(1),Florida Statutes,effective Dctober 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal
address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,
please dick here.
Product Approval Accepts:
UIWAN ""leek E
Credit Card
Safe
https:/Moridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT%2b6w7ahReglCQ8ucR6ixEA65bxB8ctyag%3d%3d 2/2
EXTERIOR RESEARCH&DESIGN, LLC.
Certificate of Authorization#9503
TRINI 1 1 353 CHRISTIAN STREET, UNIT#13
ERD OXFORD,CT 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
Owens Corning Evaluation Report 037940.02.12-R7
One Owens Corning Parkway FL10674-1112
Toledo,OH 43659 Date of Issuance:02/06/2012
Revision 7: 04/18/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
V...
41
` y _
The facsimile seal appearing was authorized by Robert Nieminen,
Robert J.M.Nieminen,P.E.
..!Jp I';L ssts• P.E.on 04/18/2016.This does not serve as an electronically signed
Florida Registration No.59166,Florida DCA ANE1983 document.Signed,sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity lERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY ERS
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated
compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume
through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008
3. REFERENCES:
Entity Examination Reference Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic and Supreme are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 Devonshire'"'are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 Duration, TruDefinition Duration, Duration* Premium Cool, TruDefinition' Duration Designer Color
Collection, TruDefinitionOakridge*, Oakridge and WeatherGuard' HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Berkshire* Hip & Ridge Shingles, High Ridge, WeatherGuard* HP Hip & Ridge Shingles, ProEdge Hip & Ridge
Shingles and DuraRidge"Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
4.3 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R7
Certiftcate of Authorkatlon#9503 FL10674-R12
Revision 7:04/18/2016
Page 2 of 8
y
'--J TRINITY ERD
5.4 Wind Classification:
5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for
use in all wind zones up to Vasa= 150 mph (Vnit= 194 mph). Refer to Section 6 for installation requirements
to meet this wind rating.
5.4.2 All Owens Corning hip&ridge shingles,Starter Strip Shingle and Starter Strip Plus noted herein are Classified
in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F, indicating the shingles are
acceptable for use in all wind zones up to Vasd= 150 mph (Volt=194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less.
Calculations by a qualified design professional are required for conditions outside these limitations. Contact
the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3.
6_2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using
minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following
exceptions:
➢ Berkshire*shingles require minimum five(5)nails per shingle.
➢ WeatherGuarde HP shingles require minimum six(6)nails per shingle.
➢ Devonshire'"shingles require minimum six(6)nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus:
Felt underlayment Deck FeRurderhyment i. Deck Self-adhered
Weathed.ockf
? Self-adhered undedayment
WeatherLocka J%
undedayment
Drip edge
Dr1edge -;y( Drip edge Drip— ;a
9 edge
Nails located Nail located
2"-3"from eave 2',T from save
Install first Self-sealing adhesive 7 SaM�eaGnp adhesive
Starter Strip - positioned along eave Instal first Starter Strip Plusrv �
positioned along eave
shingle with \ with 6'removed------.---—
6"removed '.3" Starter Strip Plus overhangs eaves and rakes 7/4'-3/4
Starter Strip shingle overhangs eaves and rakes .-, 4 n9
Exterior Research and Design,U.C. Evaluation Report 037940.02.12-R7
CertfJlcate oJAuthori:atlon#9503 FL10674-R12
Revision 7:04/18/2016
Page 3 of 8
TRINITY ERD
6.2.6 Minimum Nailing—Classic®&Supreme:
1 . r r
Normal Mansard or Area para Normal Mansard or Area pare
Wind Areas High Wind desvanes y Wind Areas High Wind desvnnes y
Area pare vientos normal@$ Areas vientos fuertes Area pars vientos normales Areas vientos fusrtea
�' !AI t.. t z l (B `2. t•� t !A► r r 2• !B) 2' t' I
+• tr u ut
5"Exposure 5 5/8"Exposure
Exposicidn Exposici6n
6.2.7 Minimum Nailing—Berkshire®:
Sealant strip Sealant strip
La IN do segador la tka de seflador
News
8 Sh" 9 Yf 9✓t 8 Vf t „8 Li' 81"'. e tY' e bz"
�„ t.J 1 t,.
r
r
Standard Fastening Pattern 6-Nail Fastening Pattern
Sealant strip
La ria de sellador
eF-ie4ie e -e
1�"8� s,h" 8+rf 8 Y
� t•J
t -
? Asphak roofing content
Contenro de lecW da asfalto
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R7
Certificate of Authorization#9503 FL10674-1112
Revision 7:04/18/2016
Page 4 of 8
TRINITY ERD
6.2.8 Minimum Nailing—Devonshire'":
8" 1 8" I 7" i
N —
tlevw
Nails
5.5/8°exposure
Sealant location
Expaski in de 5.518 pulp Sealant
del sellador
Ten 1"Spots of Asphalt Roof Cement
Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing—Duration®,TruDefinition® Duration, Duration® Premium Cool &TruDefinition• Duration*
Designer Color Collection:
4-Nail Fastening Pattern e-Nail Fastening Pattern
s—H ft fasbnieg—MO h s l.Na118:MW..Ing an"Moth
Na4lyP.A Nail lyp"
t^I 12^ , 1r 1'• 1" 12^
ctn^ aa+a^ ctre- a-ara^
U �7
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening for Slopes Greater Than 21:12
SurMUiY++�faftil q VN MON
_ i N"q.1YVlu1 _
bL7'S•a/a"
• :2-
F 1"Spon of AspMR Rooeng C.—nt
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-117
Certificate of Authorizatton#9503 F1.10674-1132
Revision 7:04/18/2016
Page 5 of 8
TRINITY ERD
6.2.1 Minimum Nailing—TruDefinition•Oakridge®,Oakridge®:
4 Nail Pattern 6 Nail Pattern
Esquema con 4 clavus Esquema con S clavus
1. 1,
IE—
12' —>I fE— 12
Imo-- 12'
5 5/8"Exposure Nags 5 5!8"Exposure Nails
Exposlciondebb/8pulg. Clams Exposiddnde6G19pulg. 55,18"Exposule Clavos 55/8" . posula
Exposici6n de 5 6/8 pulg. Exposid6n de 6 6/8 ping.
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening for Slopes Greater Than 21:12
suraNallm,hstanmg ana wim
Nal,Typical
i" iT -------ir-------'-
Wr
41,7'
Four 1-spots of Asphalt Roofing Camanl
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing—WeatherGuard®HP:
1. single We View
fs— r 1;:=sl
:t':: ia.e.nr 71.wgi INsil Lis.
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R7
Certificate ofAuthorizatlon#9503 FL10674-R12
Revision 7:04/18/2016
Page 6 of 8
TRINITY ERD
6.3 Hip&Ridge Shingles:
6.3.1 Installation of Berkshire* Hip and Ridge Shingles, High Ridge, WeatherGuard*HP Hip and Ridge Shingles and
ProEdge Hip&Ridge Shingles shall comply with the manufacturer's current published instructions, using four
(4) nails per shingle. Installation of DuraRidge'" Hip & Ridge Shingles shall comply with the manufacturer's
current published instructions, using two (2) nails per shingle. Refer to Owens Corning published
information on wind resistance and installation limitations, including the use of hand-sealing for wind
warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge:
Fig.1 4 Fig.2
E— Prevalanp Mind
Direction A TopVtew Sidovlew
�s—__.__�� A Nabs Nails
4
I I r Top LaminaW r 7 1
A I I 1• Piece
A 1 I �• T
4 I
A I I 1 1 I
Esposlrs I
ul
I
I
I
I
I
I
6.3.4 Minimum Nailing—WeatherGuard®HP Hip and Ridge:
Fi
Fig.C Hip&Ridge Shingle Fastening
44
9•A Topvbw
PrvYallalg Wbd
�—gwctbn p
A
I 1
A I i t1aIY WIY
1 1 I i 1• 1•
A I I 1
EXPOMp
S' FYPuauw
17.
Exterior Research and Design,U.C. Evaluation Report 037940.02.12-R7
Certificate of Authorization#9503 FL10674-R12
Revision 7:04/18/2016
Page 7 of 8
TRINITY ERD
6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles:
Prevailing Standard 11'
Wind DirectionFastening
Sealant Strip Pattern 1
6'Exposure s/�F 2'.j12,
�' 't•� I-
12' 1 Sealant
Fasten 71h" 7'h"
8"Ezposire
Cover Exposed +
Fasteners with
Roof Cement _12l
6.3.6 Minimum Nailing—DuraRidgeT'Hip&Ridge Shingles:
Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
Pro.aifng Wind Dirocdan Top View
r—Diroaiondxnlmncoduranc Vaeeoplan
Dirocdw dol vianto prodcrninsnco I' VBca sigerior I'rf
�Ctuu
lhreM Cotdrag S,ardJa7 •
NLS —► -._-.._.s:�
• I I I
a•I�a
I°�x�iytNl V i�c
- `g —
o I~ 12_�
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(414)248-6409; karen.buchmann@ul.com
- END OF EVALUATION REPORT-
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R7
Certificate of Authorization#9503 FL10674-1112
Revision 7:04/18/2016
Page 8 of 8