Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval
Michelle Franklin, CFA—Saint Lucie County Property Appraiser—All rights reserved. Property Identification Site Address:9412 Scarborough CT Parcel ID:3322-507-0009-000-7 Sec/Town/Range:22/36S/39E Account#:158666 Map ID:33/22N Use Type:0100 Zoning:PUD Jurisdiction:Saint Lucie County Ownership Allan L Howard Mary R Howard 9412 Scarborough Cts Port St Lucie,FL 34986 e Legal Description • - PODS 12 AND 13 PUD 1 AT THE RESERVE SCARBOROUGH ESTATES(PB 45-13)LOT 4(OR 2864-723) Current Values -% JustlMarket Value: $491,800 Assessed Value: $410,8787- -'1 Exemptions: $55,000 Taxable Value: $355,878 Total Areas Taxes for this parcel: SLC Tax Collector's Office© Finished/Under Air(SF): 3,428 Download TRIM for this parcel:Download PDF 12 Gross Area(SF): 6,259 Land Size(acres): 0.31. Land Size(SF): 13,634 This information is believed to be correct at this time but it is subject to change and is not warranted. ©Copyright 2017 Saint Lucie County Property Appraiser.All rights reserved. I i I BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats B Facts Publications IBC Stair BCIS Site Map Links Search i SOI"ICS' � I i i ,.I Product Approval ii I f li USER:Public User i > > >Application Detail I e _ 7-1211 FL# FL17347-R2 Application Type Revision i Code Version 2017 j Application Status Approved i Comments Archived II I � Product Manufacturer Plastpro Inc./Nanya Plastics Corpi ' Address/Phone/Email 5200 W CENTURY BLVD. LOS ANGELES,CA 90045 (440)969-9773 Ext 16 rickw@rwbldgconsultani.com Authorized Signature Vivian Wright rickw@rwbidgconsultants.com I Technical Representative Scott Johnson Address/Phone/Email 5200 W Century Blvd. i Los Angeles,CA 90045 1I (440)969-9773 Ext 18! scottjohnson@plastproknc.com Quality Assurance Representative � I Address/Phone/Email l I, i Category Exterior Doors 9 fi Subcategory Swinging Exterior Door A ssemblies, Compliance Method Evaluation Report from al Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received �I Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E.i the Evaluation Report � I Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ryan J.King,P.E. `� Validation Checklist Hardcopy Receivd ,I• Certificate of Independence i aI Referenced Standard and Year(of Standard) Standard Year 101/I.S.2/NAFS I, 2002 AAMA1WDMA/CSA101/IS.2/A440� I 2008 ASTM E1886 ! 2002 ASTM E1996 2002 ASTM E330 I I 2002 ASTM E331 2000 TAS 201,202,203 i' 1994 Equivalence of Product Standards j Certified By I• i I i, Florida Licensed Professional Engineer or Architect I Sections from the Code ! II f i I I' Product Approval Method Method 1 Option D Date Submitted 08/13/2017 j Date Validated 09/26/2017 Date Pending FBC Approval 09/29/2017 l j Date Approved 12/12/2017 i Summary of Products FL# Model,Number or Name Description 17347.1 a.Fiberglass Door "Non-Impact"Fiberglass Glazed Door-Single with or without Sidelites(X,OX or XO,OXO)Outswing/Inswing Configurationslup to Nominal 6'811n Height Limits of Use Installation Instructions !• Approved for use in HVHZ:No Fu i I1 i 1f Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 l Impact Resistant:No Created by IndependentThird Party:Yes Design Pressure:N/A Evaluation Reports i1s Other:See INST 17347.1 for any additional use limitations, installation instructions and product particulars. Created by IndepeIndent;Third Party:Yes 17347.2 b.Fiberglass Door "Non-Impact"Fiberglass,Glazed Door-Double with or without Sidelites(XX orIOXXO)Outswing/Inswing Configurationslup to Nominal 6'8lin Height Limits of Use Installation Instructions Approved for use in HVHZ:No Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,;P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.2 for any additional use limitations, _Ft.17'.,- installation instructions and product particulars. Created by Independent Third Party:Yes 17347.3 c.Fiberglass Door "Non-Impact"IFibergiass;Glazed Door-Single with or without Sidelites(X,OX or XO,OXO)Outswing/Inswing Configurationslup to Nominal 8'd in Height Limits of Use Installation Instructib'ns Approved for use in HVHZ:No FL17,- Approved for use outside HVHZ:Yes Verified By: lyndon F.ISchmldt,�1P.E.43409 Impact Resistant:No Created by IAdependenYThird Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.3 for any additional use limitations, �I Ins tion instructions and product particulars. Created by IndependeitThird Party:Yes 17347.4 rd.F.berglass Door "Non-Impact"I Fiberglass,Glazed Door-Double with or without Sidelites(XX or`OXXO)Outswing/Inswing Configurations up to Nominal 8'0 in Height Limits of Use Installation instructions Approved for use in HVHZ:No {_ Approved for use outside HVHZ:Yes Verified By: Lyndon F.I. chmidt;P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports i! , Other:See INST 17347.4 for any additional use limitations, F11 7 s•.- I. Af installation instructions and product particulars. Created by Independent Third Party:Yes . , 17347.5 e.Fiberglass Door "Impact"FibeIglass Glazed Door-Single with or without Sidelites(X,OX or X0,1 OXO)Outswing/Inswing Configurations up to Nominal 68 in Height Limits of Use Installation:Instructions Approved for use in HVHZ:No Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.5 for any additional use limitations, ,I installation instructions and product particulars. Created by Independelit Third Party:Yes j Ik i I II 17347.6 f.Fiberglass Door "Impact"Fiberglass Glazed Door-,Double with or without Sidelites(XX orlO)(XO)O'utswing/Inswing Configurations up to Nominal 6'8 in Height Limits of Use Installation InstructionIs p Approved for use in HVHZ:No FLt Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Paity:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.6 for any additional use limitations, FLl%4n' ` : - j;l ' Af installation instructions and product particulars. Created by IndependentIThird Paity:Yes 17347.7 g.Fiberglass Door "Impact"Fiberglass Glazed Door-;Single with or without Sidelites(X,OXIor XO,OXO)Outsw ng/Inswing Configurations up to Nominal 8'0 in Height Limits of Use Installation Instruction's Approved for use in HVHZ:No ___ I Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant,Yes Created by Ind epended' hird Party:Yes Design Pressure:N/A Evaluation Reports ! Other:See INST 17347.7 for any additional use limitations, f installation instructions and product particulars. Created by Ind pendent,,Third Party:Yes 17347.8 h.Fiberglass Door "Impact"Fiberglass Glazed Door,{Double with or without Sidelites(XX orj�O)XO)dutswing/Inswing Configurations up to Nominal 8'0 in Height a Limits of Use Installation Instructions F!_?% Approved for use in HVHZ:No ,> Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independenifhird Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.8 for any additional use limitations, FL installation instructions and product particulars. Created by Independent Third Party:Yes 17347.9 i.Fiberglass Door "Non-Impact"Fiberglass Opaque Door-Single with or without Sidelites(X,OX or XO,OXO)Outswing/Inswing Configurations up to Nominal 5'81n Height Limits of Use Installation Instructions Approved for use in HVHZ:No Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent.Third Party:Yes Design Pressure:N/A Evaluation Reports i Ij Other:See INST 17347.9 for any additional use limitations, 11 installation instructions and product particulars. Created by Inde pendent Third Paarty:Yes 17347.10 j.Fiberglass Door "Non-Impact"Fiberglass,Opaque Door-Double with or without Sidelites(XX or OXXO)Outswing/Inswing j Configurations lip to Nominal 6'8 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No Fu%'�+• •-• I I j •••-j • •';"df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independen6third Party:Yes Design Pressure:N/A Evaluation Riports Other:See INST 17347.10 for any additional use limitations,installation instructions and product particulars. Created by Independent Third Party:Yes 17347.11k.Fiberglass Door "Non-Impact"Fiberglass Opaque Door-Single with or without Sidelites(X,OX'di XO,OXO)Outswing/Inswing ConfiguCrationslup to Nominal 8'0 in Height Limits of Use Installation Ilnstructions it Approved for use in HVHZ:No Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independen. hird Party:Yes Design Pressure:N/A Evaluation Reports !I Other:See INST 17347.11 for any additional use FL I _ limitations,installation instructions and product particulars. Created by Independent�Third Party:Yes 17347.12 I.Fiberglass Door "Non-Impact"Fiberglass dpaque;Door-Double with or without Sidelites(XX or;O)(XO)O"utswing/Inswing Configurations!up to Nominal 8'0�in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL _,Jf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,I' .E.43409 Impact.Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.12 for any additional use ;� limitations,installation instructions and product particulars. Created by Independen.;Thlyd Party:Yes 17347.13 m.Fiberglass Door i it , Il RW R W Building-Consultants, Inc. B Consulting and Engineering Services for the Building Industry I C P.O.Box 230 Valrico,FL 33595 Phone 813.659.9197 I Florida Board of Professional Engineers Certificate of Authorization No.9813 I ' Product / Report Mae: April 15, 2015 I I Product Sub Category Manufacturer Pioduct Name Category Plastpro Inc. j; Glazed,Fiberglass Doors Exterior Swinging en 5200 W.Century Blvd. Doubles I Doors Exterior Door 1 Assemblies Los Angeles,CA w/or w/out Sidelites Phone 440.969.9773 Inswing/Outswing':-"Non-Impact" Scope: Product Evaluation report issued by R W Building Consultants, Inc.&Lyndon F.iSchmidt,,P.E.(System ID#1998)for Plastpro Inc.,based on Rule Chapter No.61 G20-3,Method 1 D of the State of Florida Product Approval,Department of Business&Professional Regulation. RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1.i This product has been evaluated and is in compliance with the 5th Edition(2014)Florida Building Code structural requirements excluding the"High Velocity Hurricane Zone". I. 2 Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3.11 When used in areas requiring wind bome debris protection this product is required to be protected with an impact resistant covering that complies with Section 1609.1.2 of the FBC. I' 4.1 For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5 Site conditions that deviate from the details of drawing FL-17347.4 require further engineering a nalysisil by a licensed engineer or registered architect 6. See drawing FL-17347.4 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 01390410 ASTM E330-02 Testing Evaluation Lab:;Inc. V.K.Wright TEL 01390454 ASTM E330-02 Testing Evaluation Labl;lnc. V. K.Wright TEL 01391140 ASTM E330-02 Testing Evaluation Lab., Inc. V.K.Wright TEL 01391119 ASTM E330-02 Testing Evaluation Lab,;lnc. V.K.Wright HTML 0339-0820-03 ASTM E330-02 Hurricane Test Laboratory V.J.Abraham TEL 01391120 TAS 201,202&203-94 Testing Evaluation Labillnc. I I William B.Shelton, P.E. 2: Drawing No. Prepared by I' Signed&Sealed by No.FL-17347.4 RW Building Consultants, Inc.(CA#9813) Lyndon F.Schmidt,P.E. 3: Calculations Prepared by Signed&Sealed by Anchoring RW Building Consultants, Inc.(CA#9813) Lyndon F.Schmidt,P.E. 4. Quality Assurance Certificate of Participation issued by National Accreditation and Management Institute,certifying that Plastpro Inc.is manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and Guide 53. ar.,;,.Iif.r Eqr� ea W: .az ocr i o ,z`''s(°It� ties I° •,4a'' Lyndon F.Schmidt,P.E. �'� itaeurua� sLL ; FL PE No.43409 4/16/2015 Sheet 1 of 1 , I II I 74°MAYOVERALL FRAME WIDTHplastpro • L'; Z�' AK 5200 W. CENTURY BLVD. LOS ANGELES, CA 90045 W a Z -ZJ Z m o ^ L- Z? _ 9 0°l w — X _ W -- - -- -- - GLAZED FiBERGL�►SS-DOORS— -- --- - -__- = -- - -- - - -- a -=-� - -- DOUBLES o �' ` `Z =-_- - _- ------ vv-/_ - -- -- or-W- ==o SIDELIT - ------------- --_-_ ---------a--a _ -- _- ----- - ----- _ ----_----- - -- - INSWING/OUTSWING " �Z "NON-IMPACT" 0o Z� GENERAL NOTES tLg 4y'JI� 148.5'MAX.OVERALL FRAME WIDTH j I. This product has been evaluated and Is in compliance with the 5th Edition f-—74"MAX.FRAME WIDTH 3E MAX.FRAM '^ (2014)Florida Building Code(FBC)structural requirements excluding the of � 0: a "High Velocity Hurricane Zone"(HVHZ). a a 2. Product anchors shall be as listed and spaced as shown on details. m Anchor embedment to base material shall be beyond wall dressing or F�2 stucco. LQ m = W 3. when used in areas requiring wind bome debris protection,this product 6 z z S required to be protected with an impact resistant covering that complies g O X X O Z 8 with Section 1609.1.2 of the FBC. Z — OO O 8 Q N 4. For 2x stud framing construction,anchoring of these units shall be the ° same as that shown for 2x buck masonry construction. a a 5. Site conditions that deviate from the details of this drawing require furtherLL o $ engineering analysis by a licensed engineer or registered architect. N m TABLE OF CONTENTS a SHEENS I DESCRIPTION 1 Typical elevations,design pressures&general notes o = Door&Sldelite pane ddetailsDESIGN PRESSURE DESIGN PRESSURE z o 2 MAX PS S DAM 1018114 i 3 Lite frame glazing details CONFIG FRAME INSW NG O SWING wAm N.T.S. 9 4 Elevations DIMENSION ; 5 Vertical cross sections' a: POS.;'? ,.NEG.=- H POS:,'•«;_ NEG.'+ owc.er: JK m s" 6 Horizontal cross sections XX 74.0"x 98.0" +47,0 -47,0 +47.0 -47.0 aO.BY. LFS 3 uruww°No: rc ��Fmme ck anchoring OXXO 148.5"x 98.0^ +45.0 -50.0 +45.0 -45.0 Fl-17347.4 anchoring&hardware detailsof materials and com onents ° seer 1 of 9 3.7" 7 0.4" DOOR SKIN FOAM CORE `��.�:,••' d��� n 1.(Y' EXTERIOR 4" trr •:� n _•4T � L. J��j A �o - _ - --- m -- STILE(LVL) INTERIOR CAP PVC CAP(PVC) STEEL REINFORCEMENT LATCH STILE(LVL) ( ) Gt G2 1.413^X 0.135' g Ea -m W - --- - -- - TOP RAIL C`: 1 z (COMP.) •...�:.:`•:"i u � 0 9 o a —-- -----— —— __ ____ __ v•_._ -:O - _ \- N O- .tom,_ 1 HORIZONTAL CROSS SECTION o - - - - ---— - ----- ----- -- - - -- - - -------------- -- ---- -- -- 35.7S'MAX.PANEL WIDTH a o � p �Fz �n0 GI G2 a� ` oa p j EXOTERIOR INTERIOR � � � a a 23 3 C • N Ed (n 0 z LD••• ••- _N O FOAM CORE '4', ° (POLYURETHANE- ° w DOORLOCKHAR0WAkETAEIf 1.9 PCF MIN.) •r' � MA4FACTURER MODEL: ° •' FIBERGLASS SKIN i f KWIKSET KNOB: SERIES(400) (0.075'MIN.THK.) SEE DOOR LOCK DEADBOLT: SERIES(660) •,', i .a , ,•. HARDWARE TABLE YALE KNOB: CIRRUS 100 C DEADBOLT: 820 SINGLE CYLINDER BOTTOM RAIL (COMP.) z ° Dm- 10814 scr: N.T.S. 42 ) owa er: JK m 5PLASTPRO DOOR PANEL40 CWL W. !FS ; 50 PIASTPRO S1DEl1TE PANEL2 VERTICAL CROSS SECTION N0 7347 4 c iSHM_L r 24,13"MAX. FRAME WIDTH 23.50'MAX.LIGHT n 21.13"MAX. FRAME WIDTH t,, D.L.O.WIDTH 20 50"MAX * z n D.L.O.WIDTH : N:• c #8 X 1-1/T PPH SMS i Z #6 X 1-3/4"PPH SMS 3A RSL 11TE FRA ME� ' Ln • ?D° _ IR o#8X1-1/TPHSMS 1h zc Z m In O PO `)1.44"- ODLL wa HPPoRy J m #6 X 13/4"PPH SMS 0 o 3.25" 7 a X �P) �P) ODL LITE FRAME RSL LITE FRAME a N flf Z #8 X -1 T P*IOR ITE 3/8" #6 X 13/4 PPH SMS 3/8"GLASS BITE B N INTERVERALL GLASS THK. INTERIOR 1/T OVERALL GLASS THK.c 2 w 1/8"TEMPERED G 1/8"TEMPERED GLASS k AIR SPACE g E $ AIRSPACE �" 1/8"TEMPEREDGLASS IffTEMPEREDGLASS w = g EXTELUMINUM SPACER HOT BUTYL SEALANT(ADCO) _ Ic I SEAL GLAZING COMPOUND CONTINUOUS o ° EXTERIOR MEfALSPACER wie 10/8/14 ° 3A : Bw� N.T.S. ° Gl GIALNG DEVIL G2 GLAIING DETAIL DwD.By.. JK m 5 cNu.Br. LFSEr 3 DRAwDlG N0-' rc FL-17347.4 ° mcm-jL DF 9 6 I ,P-Aaelds\Aestpm,Inc PERMANENT\FWdda Product APPmvaislfl-1734AC-DraMngs%Curtent\FL-17347.1-.4.dwg,4.4 ' I II P W 1 I I ' I 1 a Iia 0 0 II i �o I wN Z I I � U1 ao I I ! I I . I w� E1�N I 00 040 II I OZ \� aP li 1 4n oo I I 1 , 1 I. I a P A I I' i I ,%'* *1SCHM/i���i' No.43409 ' PRODUCT: Documents Propalsd ey:� PIASTPRO Lyndon F.'Sehm � ��•� FIBERGLASSid! BERGLASS DOOR ?.E No. 43409 ��i� ���� o, NAI. .�• PARI OR ASSEMBLY: RIP BUILDING CONSULTANTS, INC:* Iv to 1 14 15 UPDATE TO 5TH ED. 2014 FBC JK P.O. Box 230, Valrico, FL 37895 lo 4+ NO DATE BY ELEVATIONS phone No.:, ,8 REVISIONS FBPE CA No. 9813 ®..R.W.BU ILCIND C.CNSULTwNT9 INC. 1 I' I I ,� D E D ..a: ..a: � ..d �N•:'� Z �:��N o m 12 LI v i oZc�i _ C- 40 ] SEE NOTE 1 6 24 E Z --- — z-- ----- - — — 5p V __ _ -- — -- --— o INTERIOR EXTERIOR 40 1 U INTERIOR EXTERIOR 11 11 z EXTERIOR 1 VERTICAL CROSS SECTION 2 VERTICAL CROSS SECTION 3 VERTICAL CROSS SECTION m cw $ Inswing s own ou ng similar) $ InsMnng shown Ouiswing milar $ Insm shown(Outswing simtlar( D ao Gu, 2X Buck Construction 1X Buck Construction 2X Buck Conshuction gm „ 8 VERTICAL CROSS SECTION I C $ ADA Sill a a NOTE: 1.Spacing for item J @ head&sill:6'from each end, m 10 centerline,2 additional at X&4.5"from end INTERIOR EXTERIOR INTERIOR EXTERIOR adjacent to door. fti a ^ INTERIOR FEXTERIOR INTERIOR EMERIOR o 40 J 50 N o 6 25 22 40 SEE NOTE 1 J 50 8 V) 20 26 21 27 SEE NOTE 1 ® � 25 23El � o DATE 10/8/14 = D D D D sc : N.T.S. DM.BY. JK m e 4 VERTICAL CROSS SECTION 5 VERTICAL CROSS SECTION 6 VERTICAL CROSS SECTION - 7 VERTICAL CROSS SECTION DDRAWND NO.:LFS a $ inswing sill $ outswing sill $ Inswing sill $ Inswng sill FL-17347.4 m bsir 5 OF 9 E 0.15 C F c'sINK E o.ts' 0,15' E C C C'SINK Q:'• '�' °" 1 C'SINK p p '�"• N •e SEE NOTE I . �'°• �J i>t0 a 7 EXTERIOR •, f F �''' .-• o c ri ,40 =__- - -- - _ - - -- -- ! j IL\aentslMasNlo,Inc PERMANENT\Florlda Product Approvals\R-17347\C-Drawings\Current\FL-17347.1-.4.dwg,7.4 I. - '� ii I 1 0 i i Al I� II I I I, I" 16"O.C. (N — ! MAX.(TYP) P) �, h Ij I I ! ll I i:, ••I j', i� In S?o li II I p a I I I � II I jJ E d I �I II , L' ! It .I 16,O.C. RYP) MAX.PP) I I1 ``,lpinr4q��' I, %..`F,SCNIy No.43409 s PRODUCT: D-l—ta PnpuparW�ByQ.;',% 9•• -- 1'I r< PLASTPRO ! Lyndon F.I'Schmidt 1 ,%. ••• ORIOIS••(j���� I� V Z o FIBERGLASS DOOR P.E.E. No. 3409 it "1"1' ` t— a -{ m PART OR ASSEMBLY: Kn,'BUILDING CONSULTANTS, INC. .v x lq 1 14 15 UPDATE TO 5TH ED. 2014 fBC JK rl l.Ui/ Ir° {' NO DATE BY BUCK ANCHORING DDD F'.0. Box 230, VDlrlpo, FL 33595 Phone No.: 813.859.9197 REVISIONS FSPE C.A.PN.. 8813 0 2D 14 R.W.BUILDING CONBULTANTB IND. i I! I II