HomeMy WebLinkAboutProduct Approval (3) i
nil
::I► 11t
Business & ,Professional Regulation
SCIS Home I Log In I User Registration Hat Topics I Submit Surcharge i Stats&Facts Publicatlons I FI CStaff I SCIS Site Map Links Search
bo
•
Product Approval
r USER:Public Userdr
I
I.
Product Approval Menu>Product or Application Search>Application List>Application Detail
FL# FL2847-R9
Application Type Affirmation �' f
Code Version 2017 1'.
Application Status Approved
Comments
I
Archived I,!
Product Manufacturer Lomanco,'Inc
Address/Phone/Email 2101 West Main Street
Jacksonville,AR 72076
(501)982-6511
acarter@lomanco.com
Authorized Signature Andrew Carter
acarter@lomanco.com I,I
I ,
Technical Representative Andrew Carter i
Address/Phone/Email 2101 West Main Street
Jacksonville,AR 72076
(501)982-6511 Ext 361
acarter@lomanco.com
Quality Assurance Representative Andrew Carter
Address/Phone/Email 2101 West Main Street
Jacksonville,AR 72078 ;j j I�
(501)982-6511 Ext 361!'
acarter@lomanco.com
Category Roofing
Subcategory Roofing Accessories that are.an Integral Part of the Roofing
System
I
1 Compliance Method Evaluation Report from a Product Evaluation Entity
II
Evaluation Entity Miami-Dade BCCO-EVL
Quality Assurance Entity Miami-Dade BCCO-QUA I+
Quality Assurance Contract Expiration Date 09/04/2018 'I
Validated By Miami-Dade BCCO-VAL
I it A
Certificate of Independence
IIS 1
Referenced Standard and Year(of Standard) Standard �!', Year
Miami-Dade TAS 100(A) 1995
1 I�i
1 Equivalence of Product Standards j
Certified By
Sections from the Code I' ;
DI affirm that there are no,changes in the new Florida Building
Code which affect my product(s)and my product(s)are in
compliance with the new Florida Bui ilding Code.
ii .I
Documentation from approved Evaluation or Validation Entity
O Yes O No O N/A
Product Approval Method Method 1 Option C I '
III '
Date Submitted 11/08/2017 !
Date Validated 11/08/2017
Date Pending FBC Approval j
Date Approved 11/12/2017 I'
i
Ili is
Summary of Products
FL# Model,Number or Name Description I ! I
2847.1 Lo-OmniRidge LOR9-4 Gun Nailable 4'Ridge Ventjfor 9"Cap Shingles
Limits of Use Installation Instructions i.
Approved for use in HVHZ:Yes FL2847 R9 II ILOR9-4 13070110.0f
Approved for use outside HVHZ:Yes Verified By: Miami-DadeiBCCO-EVL
Impact Resistant:N/A Created by Independent,Third Palmy:
Design"Pressure:N/A Evaluation Reports j
Other: 1.Refer to applicable building codes for required FL2847 R9 AE LOR9-4113070110.odf
ventilation.2.Omni Roll Ridge Vent shall not be installed on !
roof hips.3.Omni Roll Ridge Vent shall not be connected at i
ridge intersection,nor within 12"of any side wall or roof
protrusion,with a ventilation slot clearance of 12"from such j u
obstructions.4.Omni Roll Ridge Vent shall not be installed
on roof mean heights greater than 33 feet.
2847.2 Lo-Omn!Roll LOR-30 30'Gun NailableShinglel0'ver Ridge Vent
Limits of Use Installation Instructions
! Approved for use in HVHZ:Yes FL2847 R9 ILILOR-30 11070111.Ddf
Approved for use outside HVHZ:Yes Verified By: Miami-DadeECCO-EVL
Impact Resistant:N/A Created by Ind'ependent!Third Party:
Design Pressure: N/A Evaluation Reports '!!!
Other: 1.Refer to applicable building codes for required FL2847 R9 AE LOR-30i 1307011'1.Ddf
l ventilation.2.OmniRidge Vent shall not be installed on roof
mean heights greater than 33 feet.
i ii I
j 2847.3 OmniRidge OR-4 4'Shingle OveriRidge Vent a
i Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL2847 R9 II Lomanco'i(jR-4- 40A 16051027.Ddf
Approved for use outside HVHZ:Yes Verified By: Miami-Dade.1B000-',EVL
I Impact Resistant:N/A. Created by Independent Third Party:
Design Pressure: N/A Evaluation Reports
Other: 1.Refer to applicable building codes for required FL2847 R9 AE Lomanco OR-4"NOA 16051027.odf
ventilation.2.OmniRidge Vent shall not be installed on roof
mean heights greater than 33 feet.
• i,l,
Back Next 1 1 '
Iii I
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to,a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions;please contact 850.487.1395.-Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
emails provided may be used for official communication with the licensee.However email addresses are public record)If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please
click here. III' N
Product Approval Accepts:
Credit Card
Safe
I �il
i
I
�; I 'k
• 1
`1tfilif�pnl "s'
Business &Professional1 1 5
A
SCIS Home Log In I User Registration Hot Topics I Submit Surcharge Stats&Facts Publications I FBC Staff SCIS Site Map Links Search
Florida
Product Approval
USER:public User
Product AVpEo.1 Menu>Product or Application Search>Application List>Application Detail III k,
.FL# FL2569-1113
Application Type Revision �I
_Code Version 2017 !'
f Application Status Approved {
Comments
Archived, ❑. ,j i'
II i
a i� it
Product Manufacturer Soprema,Inc. (Canada) i
Address/Phone/Email 1640 rue Haggarty
Drummondville,NON-US 00000
(819)478-2400
memathieu@soprema.ca
Authorized Signature Marc-Etienne Mathieu
memathieu@soprema.ca
Technical Representative Marc-Etienne Mathieu
Address/Phone/Email 1688 Jean-Berchmans-Michaud it
Drummondville,NON-US 00000
f (819)478-2400 Ext 3327
memathieu@soprema.ca
i
i '
Quality Assurance Representative Jean-Francois Cote,Ph.D.
I
Address/Phone/Email 1640 rue Haggarty I
Drummondville
j (888)811-3145
jfcote@soprema.ca
I
Category Roofing I i
Subcategory Underlayments
Compliance-Method Evaluation Report from a Florida Registered Architect or a Licensed
I Florida Professional Engineer
❑ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert]. M.Nieminen j
the Evaluation Report
Florida License PE-59166 '
! Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 07/18/2020
Validated By John W.Knezevich,PE
'I
0 Validation Checklist-,Hardcopy Received
f I it ;i
Certificate of Independence FL2569 R13 COI 2017 O1 COI Nieminen odf
Referenced Standard and Yearof Standard)) Standard , 'r Year
ASTM D1970 i 2015
ASTM D6163 2008
FM 4474 2011
FRSA/TRI April 2012(04-12) !L: 2012
TAS 110 I 2000
UL 1897 2012
II
I I'I
• f,i
i4 I
Equivalence of Product Standards I i,
Certified By III 1!
SII ,i
Sections from the Code
.I.
II7
1 '
j Product Approval Method Method 1 Option D
I
Date Submitted 10/09/2017 '
Date Validated 10/11/2017 y
Date Pending FBC Approval 10/15/2017
I"'I
Date Approved 12/12/2017
Summary.of Products
i.
i FL# Model,Number or Description
Name ,
2569.1 Soprema Roof Self adhering roof underlayments
Underlayments I,I
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL2569 R13 II 2017 10 FINAL ER SOPRENIA CA UNDERLAYMENTS FL2569-
Approved for use outside HVHZ:Yes R3 df "
Impact Resistant:N/A Verified By: Robert Nieminen,P.E.IPE-5916611
Design Pressure:+N/A/-150 Created by Independent Third Party:Yes I
Other: 1.)Refer to ER Section 5 for Evaluation Reports
Limits of Use.2.)The design pressure FL2569 R13 AE 2017 10 FINAL ER SOPREMA CA1I UNDERLAYMENTS FL2569-
noted herein pertains to,underlayment R13.Ddf I I11
systems used beneath adhesive-set tile Created by Independent Third Party:Yes
systems.Refer to ER Section 5.6.4 for
details.
I • I�
I II
Back Next � i
�• 1 1
Contact us;;2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
1 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::acceIIIssibility Statement::Refund Statement
' JI I
Under Florida law,email addresses are public records.If you do not want your e-mail address released I I response tlol,public-records request,do not send electronic
I mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions;please confect 850.487.1395.-Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
emalls provided may be used for official communication with the licensee.However email addresses are public record:lif you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please
click here. I o
Product Approval Accepts: C
� i—A 99- M
ISI i j
Credit Card j I
Safe j
I '
I
I '
• I •
r
I
i
.I
EXTERIOR RESEARCH &DESIGN, LLC.
i I Certificate of Authorization#9503
TRINITY ERD 353 CHRISTIAN STREET,UNIT#13
I I' OXFORD,CT 06478
i (203)262-9245
EVALUATION REPORT
Soprema, Inc. Evaluation Report S18010.06.09-R11
1640 rue Haggerty I FL2569-R13
I
Drummondville,Quebec J2C 5P8 Canada (Date of Issuance:06/15/2009
(819)479-2400 11. Revision 11:10/06/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
I .I
construction materials in the State of Florida. The documentation submitted has been 'reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code , Residential Volume. The
products-described herein have been evaluated for compliance with the 6th Edition i(2017)lFlorida Building Code
sections noted herein.
DESCRIPTION: Soprema'Roof Underlayments
LABELING:, Labeling shall be in accordance with the requirements the Accredited Quality As Agency noted
I herein. i�,
CONTINUED COMPLIANCE:This Evaluation Report is valid until such time as the named prod ,uct(s) changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the productchange. Acceptance of
i this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall b'e done;in its entirety.
INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
I its distributors and shall be available for inspection at the job site at the request of the B`uildingiOfficial.
This Evaluation Report consists of pages 1 through 8. ;
Prepared by: N
�1�U�r�a trp•�rr �:I' !
`���.,t�.:...':r� 4•. ISI;
If —a. + ••�= III I
Robert J.M.Nieminen,'
P.E. The facsimile,sealappearingwas authorized byRobert
Florida Registration No.59166,Florida DCA ANE1983 t.'bsv1�4 anti;:• Nieminen,P.E!on 10/06/2017.This does not serve as an
electronically'signed document.
CERTIFICATION OF INDEPENDENCE: I �
1: Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest;in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing p'ro ducts it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturingor distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
_ 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way,the,Designer of Record for any
project on which this Evaluation.Report,or previous versions thereof,is/was used for permitting,,or design guidance unless retained
specifically for that purpose.
II`
f ;
I i ill 'i
FRINITY I ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
I Iii
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the
following sections of the 61h Edition (2017) Florida Building Code through testing inlaccordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations;% Con�'ditions of Use set forth
herein.
2. . STANDARDS:
Section Property Standard 1 Year
1504.3.1 Wind Resistance FM 4474 fl i 2011
1504.3.1 Wind Uplift UL 1897 2012
1507.1.1,T1507.1.1,1507.2.9.2 Physical Properties ASTM 61970 ! ! 2015
1507.3.3 Physical Properties FRSA/TIRI April 20'12 „ 2012
FRSA/TRI April 2012(04-12) Physical Properties ASTM D6163 j' 2008
TAS 110 Accelerated Weathering TAS 110 I i 2000
II
3. REFERENCES: i
j Enti Examination Reference ;i Date
ERD(TST6049) ASTM D1970/TAS 110 2968.05.04-2 I' 05/14/2004
ERD(TST6049) Physical Properties 2757.02.05 02/03/2005
ERD(TST6049) ASTM D1970/TAS 110 2974.03.05-2 05/17/2005
ERD(TST6049) Wind Resistance 2778.07.05 I 07/15/2005
ERD(TST6049) Wind Resistance 2779.11.05-R1 ! 04/18/2007
ERD(TST6049) TAS 103/TAS 110 57120.11.07-2 ,i; 11/02/2007
ERD(TST6049) ASTM D1970/TAS 110 S13190.02.09-R1; 04/01/2010
ERD(TST6049) ASTM D1970/TAS 110 531370.03.10-T-1R1 04/07/2010
J
ERD(TST6049) Physical Properties/Tensile Adhesion S11150.05.10-Rli 09/09/2010
ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.09-R2' I� 10/05/2010
ERD(TST6049) ASTM D1970 537210.11.11 l 11/09/2011
ERD(TST6049) ASTM D1970 540540.02.13 1 02/19/2013
II ERD(TST6049) Physical Properties/Tensile Adhesion 543530.02.14-1 ! 02/21/2014
ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-k7645.0215 02/13/2015
ERD(TST6049) Accelerated Weathering SOPC-SC8520.14 04/17/2015
ERD(TST6049) Wind Resistance SOPC-SC14045'05.17-111 06/07/2017
M-D(CER1592) HVHZ Compliance 15-0508.04 09/24/2015
ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 I; l 03/01/2017
PRI(TST5878) Physical Properties SOP-064-02-01"I i - 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY'40 06/29/2015
UL,LLC(QUA9625) Quality Control Service Confirmation i� Exp.07/18/2020
4. PRODUCT DESCRIPTION:
4:1 Lastobond TU HT is a self-adhering, non-woven polyester fabric surfaced, SBSI modified bitumen roof
underlayment;meets ASTM D1970 and FRSA/TRI April 2012(04-12).
4:2 Lastobond Shield is a self-adhering, woven polyethylene surfaced;l SBS modified bitumen roof
underlayment available in two widths;36 and 45 inch; meets ASTM D1970�:j j
4:3 RESISTO SA SMOOTH PLY 40 is a self-adhering,woven polyethylene surfaced, SBS modified bitumen roof
underlayment;available in 3.3 ft x 65 ft rolls;meets ASTM D1970.1 I 4s4 Lastobond Shield HT is a self=adhering, woven polyethylene surfaced, hligh temperature, SBS modified
bitumen roof underlayment;meets ASTM D1970.
I
i Iii 'I
Exterior Research and Design,I.I.C. .Evaluation Report 518010.06.09-1111
Certificate afAuthoriration#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION I I FL2569-1113
Soprema,Inc. I Revision 11:10/06/2017
Page 2 of 8
Iii
I!
�I•
TRINITYERD
4.5 Lastobond Pro HT-N is a self-adhering, woven polyethylene surfaced)I SBS 1modified bitumen roof
underlayment available in two widths;36 and 45 inch; meets ASTM D1970;.' I'
4.6 Lastobond Pro HT-S is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified
bitumen roof underlayment; meets ASTM D1970.
4.7 Lastobond 195 is a self-adhering, glass-mat reinforced, sand-surfaced,; SBS modified bitumen roof
underlayment;meets ASTM D1970. ' '
jl
4.8 Lastobond Eaves Protection Sheet is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified
bitumen roof underlayment; meets ASTM D1970.
4.9 Lastobond Eco is a self-adhering, glass-mat reinforced, sand-surfaced! SBS modified bitumen roof
underlayment;meets ASTM D1970.
4.10 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced, film-surfaced, SBS modified bitumen
roof underlayment;meets ASTM D1970. I'
4.11 RESISTO LB1236 is a self-adhering, glass-mat reinforced, sand-surface SBS modified bitumen roof
underlayment,with a 36-inch sheet width; meets ASTM D1970. I j
4.12 PrimeSource Grip-Rite Eave&Valley Protector is a self-adhering,glass-matreinfo�ced,sand-surfaced,SBS
modified bitumen roof underlayment,with a 36-inch sheet width;meets ASTM 11 D1970.
4.13 RESISTO LB1244 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof
i
underlayment,with a 44-inch sheet width;meets ASTM D1970.
4.14 Colphene FR GR is a self-adhering, fiberglass reinforced, granule-surfacled, SBS modified bitumen roof
underlayment;meets ASTM D1970 and FRSA/TRI April 2012(04-12).
I�
S. LIMITATIONS: �'
!
5.1 This is.a building code evaluation. Neither TrinityiERD nor Robert Nie..!ihen, P. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previousl'versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
j5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Soprema Roof Underlayments may be used with any prepared roof cover I here the product is specifically
referenced within FBC approval documents. If not listed, a request may ole,made,to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof
covering.
5.5 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS !i
Asphalt Nail-On Foam-On Metal Wood Shakes&
Underlayment Slate
iShingles Tile Tile I i Shingles
Lastobond TU HT Yes Yes Yes °� IYes Yes. Yes
See 5.54
Lastobond Shield/Pro HT-N/RESISTO SA lil f
Yes No No �o II Yes Yes
SMOOTH PLY 40 )R,,
Lastobond Shield HT/Pro HT-S Yes No No- es r; Yes Yes
Lastobond Eaves Protection Sheet/ if ,
Lastobond 195 Yes No No INo Yes Yes
� �k
Lastobond ECO /RESISTO 1_61236,Grip-
Rite Eave&Valley Protector/RESISTO Yes NoNo ' N�
{o , Yes Yes
LB1244 III I � I
Exterior Research and Design,I.I.C. C Evaluation Report S18010.06.09-R11
j Certificate of Authorization 119503 6TH EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-1113
Soprema,Inc. I i i; Revision 11:10/06/2017
Page 3of8
I
i
i; •
i•I ��
tR
!IJ I ERD
TABLE 1: ROOF COVER OPTIONS )
z�
Asphalt Nail-On Foam-On j i I'Wood Shakes&
UnderlaymentMetal Slate
Shingles Tile Tile I I.I Shingles
Lastobond Smooth Seal HT Yes No No " Yes P Yes' Yes
Yest;,.L
Colphene FR GR Yes -Yes See 5S.I lNo Yes Yes
e+
I
5.5.1 "Foam-On Tile"is limited to use of following Approved tile adhesives/underlayment combinations.
I
TABLE 1A:ALLOWABLE TILE ADHESIVE/UNDERLAYMENT COMBINATIONS)
Adhesive Florida Product Approval I Underlayments
Dow TileBond"" FL22525 Lastobond TU HT l'!
ICP Adhesives Polyset®AH-160 FL6332 Lastobond TU HT or Colphene FR GR
5.6 Allowable Substrates: I
5.6.1 Direct-Bond to Deck:
f Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond
Pro HT-S,Lastobond TU HT,Lastobond Eaves Protection Sheet,Lastobond1195,Jastobond ECO,RESISTO
LB1236,Grip-Rite Eave&Valley Protector,RESISTO LB1244 or Lastobond Smooth Seal HT applied to:
! ➢ Plywood; ASTM D41 primed plywood; OSB;ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41
j primed Southern Yellow Pine;ASTM D41 primed structural concrete.
Colphene FR GR applied to: �•I l
Plywood;ASTM D41 primed plywood;ASTM D41 primed structural coli,rete.
I
j Note:
➢ While not required over plywood, OSB or Southern Yellow Pine substrates; Soprema recommends
priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within
24 hours.
➢ Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to
installation of the self-adhering underlayment.
I •
j 5.6.2 Bond-to-Insulation:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond
Pro HT-S,Lastobond TU HT,Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond ECO,RESISTO
LB1236, Grip-Rite Eave &Valley Protector,RESISTO LB1244, Lastobond SmoothilSeal HT or Colphene FR
GR applied to:
➢ Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached-prepared roof coverings, insulation shall be attached per
ii
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under.foam-on tile systems(Lastobond TU HT only),insulation attachment;shall ble designed by a qualified
I
If design professional and installed based on testing of the insulation/unde`rlaymeht system in accordance
with FM 4474,Appendix D,Testing Application Standard TAS 114,lAppen6x J or UL1807.
I i'I i II
ii
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
II; i
Exterior Research and Design,I.I.C. Evaluation Report S18010.06.09-1111
Certificate of Authorizationl19503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION I FL2S69-R13
i Soprema,Inc. i Revision 11:10/06/2017
I I�;
Page 4of8
' u ,
II
i
I 4 i
I
TRINITY ERD
5.6.3 Bond to Mechanically Attached Base Laver: '
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S,- Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 11195, Lastobond ECO, RESISTO
LB1236,Grip-Rite Eave&Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR
applied-to: I
➢ ASTM D226,Type I or 11 felt;Sopra-G; Modified Sopra-G. I
'I
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam-on the systems (Lastobond TU HT only),
base layer shall be attached in accordance with FRSA/TRI April 2012(04-12).
I I,
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications:i FRSA%TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam-on the systems,where
the underlayment forms part of the load-path. The following wind uplift Ii T", apply to underlayment
systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam-on tile applications.
Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,
and reflects the ultimate passing pressure divided by 2 (the 2 to i1 margWof safety per FBC 1504.9 has
j already been applied). Refer to FRSA/TRI April 2012(04-12)or FBC 1609 for determination of design wind
pressures. ! '
#1 Maximum Design Pressure=-45.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirement's to satisfaction of Authority
1 Having Jurisdiction.
Primer: (Optional) Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered. I '
f I ! '
#2 Maximum Design Pressure=-67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Elastocol 600c !"
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered.
#3 Maximum Design Pressure=-150.0 psf:
Deck: Min. 15/32-inch APA-rated BCX plywood(may Ibe installed C-side up) to meet project
requirements to satisfaction of Authority Having JurisdicI lion.
( Deck Preparation: Plywood shall be thoroughly cleaned to remove dust;and 'debris that may inhibit
adhesion. All sheathing fasteners shall be driven flush withi the surface. All sharp
splinters and wood projections shall be removed/sanded., Ii
Primer: (Optional)RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, self-adhered, shall be thoroughlylroll using hand roller and/or
weighted roller to ensure there are no voids, and ensu le' ;there!Iare no voids/bridging at
side and end-laps. !`I
#4 Maximum Design Pressure -60.0 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction. �!
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin
caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and,6-inch o.c. in three (3),
equally spaced rows in the center of the-sheet. I I;
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered
5.6.4.1 All other direct-deck, adhered Soprema underlayment systems beneath foam','-,on tile systems carry a
Maximum Design Pressure of-45 psf. I
Exterior Research and Design,U.C. iEvaluation Report 518010.06.09-R11
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION I+ ( F1.2569-1113
- Soprema,Inc. I Revision 11:10/06/2017
�I Page 5 of 8
t �
�I
�i
TRINITY,ERD
5.6.4.2 For mechanically attached Base Sheet,the maximum design pressure fort e selected assembly shall meet
or exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A',!
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1
designpressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an
attachment density designed by a qualified design professional to resisUihe elevated pressure criteria.
Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet .1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)forjZone 2/3 enhancements.
517 Exposure Limitations:
�!
Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO
L131236,Grip-Rite Eave&Valley Protector or RESISTO LB1244 shall not be,,l'eft exposed for longer than 30-
days after installation. II
Lastobond Shield,Lastobond Pro.HT-N,RESISTO SA SMOOTH PLY 40, La Itobondl Shield HT or Lastobond
Pro HT-S shall not be left exposed for longer than 90-days after installation!,;
Lastobond TU HT or Colphene FR GR shall not be left exposed for longer ttia'n 180f,days after installation.
5.8 Tile Slippage Limitations(TAS 103 per FRSA/TRI April 2012(04-12))
6
When loading roof tiles on the underlayment in direct-deck tile assemblies,,the maximum roof slope shall
be as follows. These slope limitations can only be exceeded by using battens during loading of the roof
tiles.
1 TABLE 2:,TILE,SLIPBAGE LIMITATIONS FOR DIRECT=DECK TILINSTALLf1T10NS .
Underlayment Tile Profile Staging Method !(I Maximum
I I I.!i ' Slope
Flat Max.10-t�ile stack{; 6:12
Lugged Max.10-tile stackii 5:12
Max.10-tile stack(h`ottom 24ile stack
shall be inverted ,followed by18 tiles high 6:12
on slope,as shown below)
v
Lastobond TU HT , 6
Lugged
I
Colphene FR GR Flat Max.10-tile stack l 5:12
Lugged Max.10-file stackf 6:12
ii
Exterior Research and Design,I.I.C. Evaluation Report 518010.06.09-Rll
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION I FL2569-R13
Soprema,Inc. j Revision 11:10/06/2017
f, Page 6 of 8
If
I I,
�N�JTRINITY j ERD
6. INSTALLATION: •
I
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprerna published installation
requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application,and prime the substrate with;lElastocol Stick, Elastocol
I
600c or RESISTO EXTERIOR PRIMER(if applicable).
6.3 ' a LastobondTU'HT,Lastobond,Shield,Lastobond Pro HT N mRESISTO SA SMOOTH PLY 40„Lastobond Shield.'
HT,'Lastobond Pro HT-S, Lastobond Eaves Protection Sheet, Lastobond•595, Lalstobond Eco,,Lastobond
v .; �� .a
Smooth Sea(';HT,RESISTO LB1236,Grip-Rite Eav6'&Valley Protector,RESISTO LB1244 or„C61phene FR GR ,
6.3.1 Shall be installed in compliance with. the requirements for ASTM D17' undferlayment in FRC Table
1507.1.1 for the type of prepared.roof covering to be Installed. I j
6.3.2 Non-Tile Applications:
While priming is optional, Soprema recommends priming,with ElastocolStick, EI11 stocol 600c or RESISTO
EXTERIOR PRIMER if the final roof cover is not slated for installation within 24 hours.
Apply•sheet parallel to the roof edge., Roll out approximately 10 ft of membranej�and peel back the first 3.
ft of release,film.
i 'Adhere the exposed part to the substrate and unroll the remaining membriane as far as possible.
Once the entire length of membrane is in place, peel-off the release film diagonally while holding the
membrane tight. Firmly roll the membrane into place to achieve a bond. I;
Horizontal seams should be minimum 3-inches, configured to shed water' Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course low. 11 over-granule end-laps
shall be sealed using either heat-welding or hot air welding techniques. I{
When installing at slopes above 8:12, Soprema recommends back nailing i`ii the overlap area at the top of
j the sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the!release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the�lcenteriof the valley or ridge in
each direction. For valleys,apply the sheet starting at the lowest point an work upward.
6:3.3 Tile Applications(Lastobond TU HT or Colphene FR GR only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the.
instructions noted above as a guideline:
For foam-on tile applications,reference is made to Section 5.6.4 herein forlwind resistance limitations that
fall outside the scope of FRSA/TRI April 2012(04-12).
Tile shall be loaded and staged in a manner that prevents the slippage jand/or damage to the
underlayment. See Table 2 herein,and Soprema published requirements for tile staging.
f
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9'
i
' III
Exterior Research and Design,I.I.C. Evaluation Report S18010.06.09-1111
Certificate of Authorization 119503 6T”EDITION(2017)FBC NON-HVHZ EVALUATION i I j � F1.2569-1113
Soprema,Inc. I Revision 11:10/06/2017
I Page 7 of 8
11 ii
� it
TRINITY J ERD
8. MANUFACTURING PLANTS: i
i li" fl
Contact the noted QA agency for information on product locations covered for F.AC. 61620-3 QA requirements.
The following plants have qualified products under.their respective physical properties specifications.
Plak'ti Specification Products
Lastobond Shield,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT,
Drummondville, Lastobond Pro HT-N,Lastobond Pro�fiT-S,Lastobond 195,Lastobond
ASTM D1970 Eaves Protection Sheet,Lastobond Eco,Lastobond Smooth Seal HT,
QC(Canada) ! '�' 1
RESISTO LB1236,PrimeSource Grip-Rite Eave&Valley Protector,
RESISTOLB1244
ASTM D1970&FRSA/TRI 0.4=12 Colphene FR GR
Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Eco,
Wadsworth,OH
ASTM D1970 Lastobond Smooth Seal HT,RESISTO I l,L61236;�PrimeSource Grip-Rite
Eave&Valley Protector,RESISTO LB1244 I
ASTM D1970&FRSA/TRI 04-12 Lastobond TU HT;Colphene FR GR i,i II
Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Eco,
Gulfport,MS
� ASTM D1970 Lastobond Smooth Seal HT,IRESIST&L'61236;1 PrimeSource Grip-Rite
I Eave&Valley Protector,RESISTO LB1244 {�
9. QUALITY ASSURANCE ENTITY: l
UL, LLC—QUA9625,(314)578-3406,k.chancellor@us.ul.com
-END OF EVALUATION REPORT- ! '
l
J
l j f
I'
e
Exterior Research and Design,I.I.C. I 1,Evaluation Report S18010.06.09-1111
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION ! !1 FL2569-1113
Soprema,Inc. I i j Revision 11:10/06/2017
I Page 8 of 8
I 1!I