HomeMy WebLinkAboutProduct Approval P
We'll Make you sr,lle! 4560 U. S. Hwy 1 Vero Beach, FL 32967. 772-231-5959
Facsimile trait ittaI
To: Monica Fax: 772-462-1148
From: Andy B Date: 1/2/2018
Re: License Pages: 2
Cc:
❑ Urgent ® For review ❑ Please comment Fzl Please reply ❑ Please recycle
Please see attached letter regarding GC license.
Thank you
~`ori�',��t?�p r_m�n:,M Division of Professions
Construction Industry Licensing Board
B u s i n es5' �" 1940 North Monroe Street
Professioria 1 Tallahassee,Florida 32399-1039
14 Ji �iL+l� - Phone:850.487.1395•Fax:850.921.4216
Charles W. Drago,Secretary Charlie Crist, Governor
I
STATE OF FLORIDA}
}
COUNTY OF LEON }
1', David C. Spingler, III, Representative of the Executive Director and Alternate Records
Custodian of the Construction Industry Licensing Board, Division of Professions, Department of
Business and Professional Regulation, State of Florida, after a diligent search of all records, do
hereby certify that:
SERGIO ZELIGMAN d/b/a COMMUNITY,ROOFING & REMODELING SERVICES is a
Florida State Certified General Contractor, license number is CGC 006984 and licensure status
is "Current,Active."The initial date of licensure was on 06/22/1973.
_.
Pursuant-to-Chapter 489.113(3).(g), Florida Statutes,-the above referenced license is
authorized to.engage in roofing contracting in the State of Florida.
Witness my hand and the official seal of the State of Florida this 8th day of AUGUST, 2008.
• CONSTRUCTION INDUSTRY
LICENSING BOARD
David C. Spingler; III
epresentative of the Executive Director and
Alternate Records Custodian
e
'This document is self-authenticating. Pursuant to 489.113(8) F.S., "Any public record of the
I;Ioard, when certified by the executive director of the board or his representative, may be
received as prima facie evidence in any administrative or judicial proceedings."
LICENSE EFFICIENTLY. REGULATE FAIRLY.
WWW.MYFLORIDALICENSE.COM
MIAMI-DADE COUNTY
MIAMI-S PRODUCT CONTROL SECTION
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/econoniv
GAF
1 Campus Drive
Parsippany,NJ 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Timberline HD®,Timberline®Natural Shadow®,Timberline American Harvest®,and
Fortitude"m Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA# 14-1022.20 and consists of pages 1 through 6.
The submitted documentation was reviewed by Alex Tigera.
•DADE CONOA No.: 16-0811.11
MIAMIUNTY
Expiration Date:02/21/22
Approval Date:02/09/17
Page 1 of 6
rr
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Asphalt Shingles
Materials: Laminate
Deck Tyne: Wood
SCOPE
This approves GAF Timberline HD®,Timberline®Natural Shadow®,Timberline American®Harvest®,and
FortitudeTM Shingles as manufactured by GAF as described in this Notice of Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test Product Description
Specifications
GAF Timberline HD® 13 '/4"x 39 3/8' TAS 110 Fiberglass reinforced heavy weight asphalt
Manufacturing roof shingle,with a laminate profile
Locations#1,2,3,4,5, 6,7
GAF Timberline Natural 13 '/4"x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt
Shadow® roof shingle,with a laminate profile
Manufacturing
Locations#1,2,3,4,5, 6,7
GAF Timberline®American 13 '/4"x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt
Harvest® roof shingle,with a laminate profile
Manufacturing
Locations#2,4,5,6
GAF FortitudeTM 13 '/4"x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt
Manufacturing roof shingle,with a laminate profile
Locations#1,4
MANUFACTURING LOCATION
1. Tampa,FL
2. Michigan City,IN
3. Baltimore,MD
4. Myerstown,PA
5. Ennis,TX
6. Tuscaloosa,AL
7. Dallas,TX
NOA No.: 16-0811.11
WMIAMI-DADE CouNTY Expiration Date:02/21/22
Approval Date:02/09/17
Page 2 of 6
EVIDENCE SUBMITTED
Test Agency Test Identifier Test Name/Report Date
Underwriters Laboratories,LLC ASTM D3462 4787344101 07/25/16
Underwriters Laboratories,Inc. ASTM D3462 I ICA48924 10/24/11
Underwriters Laboratories,Inc ASTM D3462 l OCA21994 04/22/11
Underwriters Laboratories,Inc ASTM D3462 l OCA28717 07/26/11
Underwriters Laboratories,Inc. ASTM D3462 05CA47541 11/10/06
Underwriters Laboratories,Inc. ASTM D3462 06CA31580 11/30/06
PRI Asphalt Technologies,Inc. ASTM D3462 GAF-101-02-02 11/02/05
Underwriters Laboratories,Inc. ASTM D3462 06NK05159 08/09/06
PRI Asphalt Technologies,Inc. ASTM D3462 GAF-098-02-02 11/08/05
Underwriters Laboratories,Inc. ASTM D3462 02NK41809 08/11/02
Underwriters Laboratories,Inc. ASTM D3462 03NK26444 10/17/03
Center for Applied Engineering ASTM D3462 257989 05/13/97
Underwriters Laboratories,Inc. TAS 107 OINK45803 04/13/94
n
U derwriters Laboratories,Inc. TAS 107 06NK05159 08/09/06
Underwriters Laboratories,Inc. TAS 107 04NK04273 02/20/04
Underwriters Laboratories,Inc. TAS 107 05CA42840 11111105
Underwriters Laboratories,Inc. TAS 107 02NK41811 11/11/02
Underwriters Laboratories,Inc. TAS 107 03CA35209 10/17/03
Underwriters Laboratories,Inc. TAS 107 04CA13850 08/30/04
Center for Applied Engineering TAS 100 257989 04/01/97
PRI Asphalt Technologies,Inc. TAS 100 GAF-044-02-01 01/13/04
PRI Asphalt Technologies,Inc. TAS 100 GAF-098-02-01 11/08/05
PRI Asphalt Technologies,Inc. TAS 100 GAF-101-02-01 11/09/05
PRI Asphalt Technologies,Inc. TAS 100 GAF-116-02-02 03/23/06
PRI Asphalt Technologies,Inc. TAS-100 ELK-083-02-01 10/16/02
ELK-084-02-01 10/15/02
ELK-085-02-01 10/14/02
ELK-086-02-01 10/24/02
ELK-087-02-01 10/21/02
ELK-088-02-01 10/16/02
ELK-107-02-01 10/09/03
ELK-108-02-01 10/09/03
ELK-109-02-01 10/09/03
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2: Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61 G20-3 of the Florida Administrative Code.
MIAMI•DADE COUNTY
NOA No.: 16-0811.11
• • Expiration Date:02/21/22
Approval Date: 02/09/17
Page 3 of 6
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail'A',attached..
5. Nailing shall be in compliance with Detail'B', attached.
LABELING
Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of
manufacturing facility, and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade
County Product Control Seal as shown below.
MIAMI-DADE COUNTY
, ...o VI g
BUILDING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
NOA No.: 16-0811.11
MiartI•Dane courvn Expiration Date:02/21/22
Approval Date:02/09/17
Page 4 of 6
DETAIL A
COURSE LAYOUT
DECK
FULL
5th
17" OFF 4th
11" OFF 3rd
6" OFF 2nd
FULL 1st
NOA No.: 16-0811.11
MIAMI•DADE COUNTY
Expiration Date:02/21/22
Approval Date: 02/09/17
Page 5 of 6
DETAIL B
OVERALL DIMENSIONS AND NAILING PATTERN
39-3/8"
(1 m)
14-1/2"-17-1/2" 14-1/2"-17-1/2"
(368-445mm) (368-445mm)
6-1/2"-9-1/2" 6-1/2"-,R-1/2"
ail guide line
13-1/4" (165-241—) (185.2a1mm) 5-3/4"-6-1/4"
(337mm) + �. (146mm-159mm)
1/2"-2-112" from bottom of shingle
(13-64
elf seal
adhesive
on back
ENHANCED NAILING PATTERN - six nails per shingle*
required by some local codes and required for enhanced wind coverage on certain products.
See limited warranty for details.
These shingles MUST be nailed a nominal 6" (152mm)from bottom of
of shingle, above the cut outs, as shown. Nails must not be exposed.
END OF THIS ACCEPTANCE
NOA No.: 16-0811.11
rfwrtt•Dant=_couNTY Expiration Date:02/21/22
Approval Date:02/09/17
Page 6 of 6
t
EXTERIOR RESEARCH&DESIGN,LLC.
Certificate of Authorization#9503
QOTRINIIY ERD 353 CHRISTIAN STREET, UNIT#13
OXFORD,CT 06478
(203)262-9245
EVALUATION REPORT
Polyglass USA,Inc. Evaluation Report P12060.02.09-1122
150 Lyon Drive FL5259-1126
Fernley, NV 98408 Date of Issuance:02/24/2009
(570)384-1230 Revision 22:03/13/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted
herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 14.
Prepared by:
cc= The facsimile seal appearing was authorized by Robert Nieminen,
P.E.on 03/13/2017. This does not serve as an electronically
Robert J.M. Nieminen,P.E. signed document. Signed,sealed hardcopies have been
Florida Registration No.59166,Florida DCA ANE1983 '`�y'�i„, ��+'"` transmitted to the Product Approval Administrator and to the
named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity)ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
t
TRINITY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the Sth Edition (2014) Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind Uplift FM 4474 2004
1504.3.1 Wind Uplift UL 1897 2004
1504.6 Accelerated Weathering ASTM G154 2006
1504.6 Accelerated Weathering ASTM G155 2005
1507.2.3,1507.3.3,1507.5.3,1507.7.3, Physical Properties ASTM D226 2006
1507.8.3,1507.9.3
1507.2.4,1507.2.9.2,1507.5.3,1507.7.3 Physical Properties ASTM D1970 2009
1507.11.2 Physical Properties ASTM D6164 2005
1507.11.2 Physical Properties ASTM D6222 2008
1507.3.3 Installation Practice FRSA/TRI April 2012 2012
1523.6.5.2.1 Physical Properties TAS 103 1995
3. REFERENCES:
9afty Examination Reference Date
FM Approvals(TST 1867) Wind Uplift 3004091 01/12/2000
PRI(TST 5878) Physical Properties PRI01111 04/08/2002
PRI(TST 5878) Physical Properties PUSA-005-02-01 01/31/2002
PRI(TST 5878) Physical Properties PUSA-013-02-01 12/23/2002
PRI(TST 5878) Physical Properties PUSA-013-02-02 12/23/2002
PRI(TST 5878) Physical Properties PUSA-013-02-03 12/23/2002
PRI(TST 5878) Physical Properties PUSA-018-02-01 07/14/2003
PRI(TST 5878) Physical Properties PUSA-028-02-01 07/13/2005
PRI(TST 5878) Physical Properties PUSA-033-02-01 01/12/2006
PRI(TST 5878) Physical Properties PUSA-035-02-01 09/29/2006
PRI(TST 5878) Physical Properties PUSA-055-02-02 12/10/2007
PRI(TST 5878) Physical Properties PUSA-061-02-02 01/28/2008
PRI(TST 5878) Physical Properties PUSA-076-02-01 02/22/2008
PRI(TST 5878) Physical Properties PUSA-083-02-01 04/14/2008
PRI(TST 5878) Physical Properties PUSA088-02-01 07/29/2009
MTI(TST 2508) Physical Properties JX20H7A 04/01/2008
MTI(TST 2508) Physical Properties RX14E8A 01/29/2009
ERD(TST 6049) Physical Properties 11752.09.99-1 02/08/2000
ERD(TST 6049) Wind Uplift 11757.08.01-1 08/13/2001
ERD(TST 6049) Wind Uplift 11776.06.02 01/16/2003
ERD(TST 6049) Physical Properties 02200.07.03 07/14/2003
ERD(TST 6049) Wind Uplift P1740.01.07 01/04/2007
ERD(TST 6049) Physical Properties P5110.04.07-1 04/11/2007
ERD(TST 6049) Wind Uplift P9260.03.08 03/21/2008
ERD(TST 6049) Physical Properties P13450.08.09 08/13/2009
ERD(TST 6049) Wind Uplift 1330540.11.09-R1 11/30/2009
ERD(TST 6049) Physical Properties P11030.11.09-1 11/30/2009
ERD(TST 6049) Wind Uplift P11030.11.09-2 11/30/2009
ERD(TST 6049) Physical Properties P11030.11.09-3 11/30/2009
D(TST 6049) Physical Properties P33360.06.10 06/25/2010
E D(TST 6049) Physical Properties P33370.03.11 03/02/2011
E)teri(r Research and Design,LLC. Evaluation Report P12060.02.09-R22
C iffc te ofAuthorization#9503 FBC NON-HVHZ EVALUATION FL5259-1126
Polyglass USA,Inc. Revision 22:03/13/2017
Page 2 of 14
I
TRINITY ERD
Entity Examination Reference Date
ERD(TST 6049) Physical Properties P33370.04.11 04/26/2011
ERD(TST 6049) Physical Properties P37300.10.11 10/19/2011
ERD(TST 6049) Physical Properties P40390.08.12-1 08/06/2012
ERD(TST 6049) Physical Properties P40390.08.12-2 08/07/2012
ERD(TST 6049) Physical Properties C41420.09.12-3 09/11/2012
ERD(TST 6049) Wind Uplift P39680.03.13 03/04/2013
ERD(TST 6049) Physical Properties P45370.04.13 04/26/2013
ERD(TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013
ERD(TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013
ERD(TST 6049) Wind Uplift P41630.08.13 08/06/2013
ERD(TST 6049) Wind Uplift P11751.05.03-R1 11/26/2013
ERD(TST 6049) Wind Uplift P11781.11.03-R1 11/26/2013
ERD(TST 6049) Physical Properties P45270.05.14 05/12/2014
ERD(TST 6049) Physical Properties 6020.07.14-1 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-2 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-3 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-4 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-5 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-6 09/08/2014
E RD_(TST 6049) Physical Properties P46520.10.14 10/03/2014
ERD(TST 6049) Physical Properties P44360.10.14 10/07/2014
ERD(TST 6049) Physical Properties P43290.10.14 10/17/2014
ERD(TST 6049) Physical Properties PLYG-SC7550.03.15 03/24/2015
ERD(TST 6049) Physical Properties P40390.04.15 04/03/2015
ERD(TST 6049) Physical Properties PLYG-SC8080.05.15-1 05/20/2015
ERD(TST 6049) Wind Uplift PLYG-SC8905.05.16-1 05/17/2016
ERD(TST 6049) Physical Properties PLYG-SC8080.07.16 07/16/2016
ERD(TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016
ERD(TST 6049) Physical Properties PLYG-SC11900.03.17 03/10/2017
ICC-ES(EVL 2396) IBC Compliance ESR-1697 11/01/2014
Miami-Dade(CER 1592) HVHZ Compliance NCA 14-0717.08 01/22/2015
Polyglass USA Manufacturing Affidavit Products Current 02/18/2009
Polyglass USA P/L Affidavit Mule-Hide Cross Ltg 03/01/2008
Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011
UL,LLC.(QUA9625) Quality Control Service Confirmation Exp.04/24/2018
4. PRODUCT DESCRIPTION:
4.1 Mechanically Fastened Underlayments:
4.1.1 Elastobase is a fiberglass reinforced;SBS modified bitumen base sheet.
4.1.2 Elastobase P is a polyester-reinforced,SBS modified bitumen base sheet.
4.1.3 Polyglass G2 Base is a fiberglass-reinforced,asphaltic base sheet.
4.1.4 Polyglass APP Base is a fiberglass-reinforced,APP modified bitumen base sheet.
4.2 Self-Adhering Underlayments:
4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,surfaced
with polyolefinic film surface; meets TAS 103.
4.2.2 Polystick MTS PLUS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced,
surfaced with poly-film surface;meets TAS 103.
4.2.3 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with an
aggregate surface;meets ASTM D1970.
Exterior Research and Design,U.C. Evaluation Report P12060.02.09-R22
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-R26
Polyglass USA,Inc. Revision 22:03/13/2017
Page 3 of 14
L
QTRINITY ERD
4.2.4 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with a
polyester fabric surface; meets ASTM D1970 and TAS 103.
4.2.5 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester
reinforced,with a granular surface; meets ASTM D1970 and TAS 103.
4.2.6 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester
fabric surface;meets ASTM D1970 and TAS 103.
4.2.7 Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet (FR) are polyester
reinforced,APP modified bitumen cap sheets;meet ASTM D6222.
4.2.8 Polystick Dual Pro'' is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass
reinforced,with a polyester fabric surface;meets ASTM D1970.
4.2.9 Polystick Tile Pro' is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass
reinforced,with a polyester fabric surface;meets ASTM D1970 and TAS 103.
4.2.10 Polystick MU-X is a nominal 54-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970 (See Section
5.8).
4.3 Mechanically Fastened and/or Bonded Underlayments:
4.3.1 Elastoflex G TU is a polyester reinforced, modified bitumen tile underlayment composed of an sand-surfaced SBS
modified bitumen back-side and granule-surfaced APP modified bitumen top-side. Elastoflex G TU is for use as an
alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap Sheet" in the "Two Ply
System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened or adhered tile roof systems.
4.3.2 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced,SBS modified bitumen cap sheets; meet ASTM D6164.
Elastoflex S6 G and Elastoflex S6 G FR are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380,
Class M)in the"Single Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened tile roof systems.
Elastoflex S6 G is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System"from FRSA/TRI
April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex S6 G FR is for use as an
alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath
mechanically fastened tile roof systems.
4.3.3 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222.
Polyflex G is for use as an alternate to Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012
(04-12) beneath mechanically fastened or adhered tile roof systems. Polyflex G FR is for use as an alternate to Heat
Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile
roof systems.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
E teri r Research and Design,U.C. Evaluation Report P12060.02.09-R22
Cetifici te ofAuthorization#9503 FBC NON-HVHZ EVALUATION FL5259-R26
Polyglass USA,Inc. Revision 22:03/13/2017
Page 4 of 14
r J
TRINITY ERD
5.5 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Underlayment Asphalt Shingles Nail-On Tile Foam-On Tile Metal Wood Shakes Slate
&Shingles
Elastobase Yes Yes Yes Yes Yes Yes
(Base Sheet In 2-ply system) •(Base Sheet in 2-ply system)
Elastobase P Yes Yes Yes Yes Yes Yes
(Base Sheet in 2-ply system) (Base Sheet in 2-ply system)
Polyglass G2 Base No Yes Yes No No No
(Base Sheet in 2-ply system) (Base Sheet In 2-ply system)
Yes Yes
Polyglass APP Base No No No No
Y (Base Sheet in 2-ply system) (Base Sheet In 2-ply system)
Polystick MTS Yes Yes No Yes Yes Yes
Polystick MTS PLUS Yes Yes No Yes Yes Yes
Polystick IR-Xe Yes No No No Yes Yes
Polystick TU P Yes Yes Yes (See 5.5.1) No Yes Yes
Polystick TU Plus Yes Yes Yes (See 5.5.1) Yes Yes Yes
Polystick TU Max No Yes Yes (See 5.5.1) Yes No No
Polystick Dual Pro Yes Yes No Yes Yes Yes
Polystick Tile Pro Yes Yes Yes (See 5.5.1) Yes Yes Yes
Polystick MU-X Yes No No Yes Yes Yes
Elastoflex S6 G Yes Yes Yes (See 5.5.1) No Yes Yes
Elastoflex S6 G FR Yes Yes No No Yes Yes
Elastoflex G TU Yes Yes Yes (See 5.5.1) No Yes Yes
Polyflex G Yes Yes Yes (See 5.5.1) No Yes Yes
Polyflex G FR Yes Yes No No Yes Yes
Polyflex SAP or SAP FR Yes Yes Yes (See 5.5.1) No Yes Yes
Mule-Hide SA-APP Cap Sheet Yes Yes Yes (See 5.5.1) No Yes Yes
or SA-APP Cap Sheet(FR)
5.5.1 "Foam-On Tile"is limited to use of the following Approved tile adhesives/underlayment combinations.
TABLE 1A:ALLOWABLE TILE ADHESIVE/UNDERLAYMENT COMBINATIONS)
A Florida Product
Adhesive Underlayments
Approval
Convenience Products'Touch'n FL14506 Polystick TU Plus,Polystick TU Max
Seal Storm Bond Roof Tile Adhesive
Dow TileBondT1 FL717 Polystick TU P,Polystick TU Plus,Polyflex SAP or Tile Pro
Polystick TU P,Polystick TU Plus,Polystick TU Max,Polystick Tile Pro,
ICP Adhesives Polyset"AH-160 FL6332 Elastoflex G TU,Elastoflex S6 G,Polyflex G,Polyflex SAP,Polyflex SA Cap
FR,Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR)
Polystick TU P,Polystick TU Plus,Polystick TU Max,Polystick Tile Pro,
ICP Adhesives Polyset®RTA-1 FL6276 Elastoflex G TU,Elastoflex S6 G,Polyflex G,Polyflex SAP,Polyflex SA Cap
FR,Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR)
Polyglass Polyl-ok Roof Tile FL17855 Polystick TU Plus or Polystick TU Max
Adhesive
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-1122
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-R26
Polyglass USA,Inc. Revision 22:03/13/2017
Page 5 of 14
QTRINITY ERD
5.6 Allowable Substrates:
5.6.1 Direct-Bond to Deck:
Polystick(all variations), Dual Pro,Tile Pro, Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet
(FR)self-adhered to:
➢ New untreated plywood;ASTM D41 primed new untreated plywood; Existing plywood;ASTM D41 primed existing
plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels
(designed and installed to meet wind loads for project).
Note: Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or
OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ ASTM D41 primed structural concrete.
Polyflex G or Polyflex G FR torch-applied to:
➢ ASTM D41 primed structural concrete.
5.6.2 Bond-to-Insulation:
Polystick(all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR)self-adhered
to:
➢ ASTM C1289, Type II, Class 1 polyisocya n u rate or Type V polyisocyanurate-composite insulation; Dens Deck
DuraGuard; Dens Deck Prime;or SECUROCK Gypsum-Fiber Roof Board.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board.
Polyflex G or Polyflex G FR torch-applied to:
➢ ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile
systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FBC Section.1504.3.1.
5.6.3 Bond to Mechanically Attached Base Laver:
Polystick (all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or
Tile Pro self-adhered to:
➢ ASTM D226,Type I or II felt; Elastobase; Elastobase P or Mule-Hide Nail Base.
Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ ASTM D226,Type I or 11 felt; Elastobase; Elastobase P, Mule-Hide Nail Base or Polyglass G2 Base.
Polyflex G or Polyflex G FR torch-applied to:
➢ Elastobase; Elastobase P, Mule-Hide Nail Base, Polyglass G2 Base or Polyglass APP Base.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam-on tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12),Appendix A,Table 1, or as listed in Section 5.6.4 herein, or as tested in
accordance with FBC Section 1504.3.1.
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all-underlayment systems beneath foam-on tile systems, where the underlayment
forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012(04-12) and are used in foam-on tile applications. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure
divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04-
12),Appendix A,Table 1A or FBC 1609 for determination of design wind loads.
Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-R22
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-1126
Polyglass USA,Inc. Revision 22:03/13/2017
Page 6 of 14
I
f� V,
TRINITY ERD
5.6.4.1 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.2 Maximum Design Pressure=-97.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x
1%"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
5.6.4.3 Maximum Design Pressure=-105 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x
1Y4"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
5.6.4.4 Maximum Design Pressure=-135 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional)PG100 or ASTM D41
Joints: Min.4-inch wide strips of Elastoflex SA-V over all plywood joints.
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.5 Maximum Design Pressure=-315 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max,Tile Pro, Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap
Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.6 Maximum Design Pressure=-622.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.7 Maximum Design Pressure=-30.0 psf*:
Deck: Min.15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.8 Maximum Design Pressure=-37.5 psf*:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP, Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-R22
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION F1.5259-1126
Polyglass USA,Inc. Revision 22:03/13/2017
Page 7 of 14
QITRINI-ry
ERD
5.6.4.9 Maximum Design Pressure=-37.5 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One(1)or two(2)layers ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
5.6.4.10 Maximum Design Pressure=-45 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One(1)layer ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c.at the 2-inch wide side laps and 4-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex G TU,applied in full mopping of hot asphalt.
5.6.4.11 Maximum Design Pressure=-45 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Two(2)layers ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 9-inch o.c.at the 2-inch wide side laps and 9-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot
asphalt..
5.6.4.12 Maximum Design Pressure=-45 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.at the 2-inch wide side laps and 18-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.13 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to-meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.14 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.15 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap.)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-R22
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION F1.5259-1126
Polyglass USA,Inc. Revision 22:03/13/2017
Page 8 of 14
I
�`,.
J TRINITY ERD
5.6.4.16 Maximum Design Pressure=-60 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.17 Maximum Design Pressure=-60 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.18 Maximum Design Pressure=-67.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base-or Polyglass APP Base(requires use of torch-applied underlayment)
Fasteners: 12 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch-applied or Polyflex G, torch-
applied.
5.6.4.19 Maximum Design Pressure=-75 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underlayment)
Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with
CMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 10-inch o.c.at the 4-inch wide side laps and 10-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch-applied or Polyflex G, torch-
applied.
5.6.4.20 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.21 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip or CMG#14 Heavy Duty with OMG 3"Round Metal Plates or CMG Flat Bottom Metal
I
Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.22 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
ISI
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R22
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-R26
Polyglass USA,Inc. Revision 22:03/13/2017
Page 9 of 14
ERD
TRINITY
5.6.4.23 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underlayment)
Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with CMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch-applied or Polyflex G, torch-
applied.
5.6.4.24 Maximum Design Pressure=-97.5 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c.at the 4-inch wide side laps and 4-inch o.c.at four(4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.25 Maximum Design Pressure=-105 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.26 Maximum Design Pressure=-112.5 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: ' 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer at all tin-caps
Base Ply: Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.27 Maximum Design Pressure=-120 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: CMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or CMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.28 Maximum Design Pressure=-120 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
5.6.4.29 All other direct-deck, adhered Polyglass underlayment systems beneath foam-on tile systems carry a Maximum
Design Pressure of-45 psf.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R22
Certificate of Authorization#9503 F BC NON-H V HZ EVALUATION F1.5259-1126
Polyglass USA,Inc. Revision 22:03/13/2017
Page 10 of 14
\,�`f TRINI� ERD
5.6.4.30 For mechanically attached Base Sheet,,the maximum design pressure for the selected assembly shall meet or exceed
that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density
designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked
with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January
2016)for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days
after installation.
Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after installation.
Polystick MTS, MTS PLUS,TU P,TU Plus,TU Max, Dual Pro,Tile Pro or Elastoflex G TU shall not be left exposed for
longer than 180-days after installation.
Polyflex SAP or SAP FR, or Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering is to be adhesive-set tile, in which case the maximum exposure is 30
days.
Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the
prepared roof covering is to be adhesive-set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum
exposure is 180 days.
5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226
roofing felt in a dry condition,tested at standard laboratory conditions. Agreement between purchaser and seller,as
set forth in Section 5.3,Note 1 of ASTM D1970-09,should be established as to slip resistance.
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application,and prime the substrate(if applicable).
6.3 Elastobase,Elastobase P or Mule-Hide Nail Base:
6.3.1 Shall be installed in compliance with the codified requirements for ASTM D226,Type II underlayment in FBC Sections
1507 for the type of prepared roof covering to be installed.
6.3.2 Non-Tile Applications:
Reference is made to the current edition of the NRCA Steep-slope Roofing Manual and ARMA recommendations for
installing shingle underlayments and flashings
Elastobase, Elastobase P or Mule-Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP or SAP FR,
Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or Tile Pro, self-adhered, Elastoflex G TU,
Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR,torch applied.
6.3.3 Tile Applications:
Reference is made to FRSA/TRI April 2012(04-12) Installation Manual and Table 1 herein, using the instructions noted
above as a guideline.
Exterior Research and Design,U.C. Evaluation Report P12060.02.09-R22
Certificate of Authorization 119503 FBC NON-HVHZ EVALUATION F1.5259-1126
Polyglass USA,Inc. Revision 22:03/13/2017
Page 11 of 14
ERD
JTRINITY�
6.4 Polystick MTS,MTS PLUS,III TU P,TU Plus,TU Max,Dual Pro,Tile Pro or MU-X or Polyflex SAP,Polyflex SAP FR,
Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR):
6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Sections 1507
for the type of prepared roof covering to be installed.
Note: Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM
D226 roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and
seller,as set forth in Section 5.3,Note 1 of ASTM D1970-09,should be established as to slip resistance.
6.4.2 Direct-to-Deck with Mechanically Fastened Roof Covers:
All self-adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule-Hide SA-APP
Cap Sheet or SA-APP Cap Sheet(FR)should be back-nailed in selvage edge seam in accordance with Polyglass/Mule-
Hide Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring-shank type with a minimum 1-inch diameter
metal disk or Simplex-type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back-nailed
using the above noted fasteners and spacing, in area marked "nail area,,area para clavar" on the face of membrane.
The head lap membrane is to cover the area being back-nailed.
All seal-lap seams (selvage laps) must be
firmly rolled with a minimum 28 Ib. hand
roller to ensure full contact and adhesion.
For Dual Pro and Tile Pro, align the edge of
the top sheet to the end of the glue pattern
(the sheet will overlap the fabric).
4 c
View of Ovelap Seam of Dual Pro and Tile Pro
All over-fabric and over-granule end-laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified
Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap.
Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets,exposed valleys,
or exposed roof to wall details
Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or
Polyglass PG500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of.the
Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be
installed in a water shedding manner.
All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 40-Ib weighted-roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches,laps(min.28 Ib roller)or small areas of the
roof that are not accessible to a large roller or broom.
6.4.3 Tile Applications(not allowed for Polystick IR-Xe or Polystick M":
Reference is made to FRSA/TRI April 2012(04-12) Installation Manual and Table 1 herein, using the instructions noted
above as a guideline.
For mechanically fastened tile roofing over 2-ply system,consisting of Base Sheet and self-adhering top sheet(s), Base
Sheet fastening shall be not less than FRSA/TRI April 2012(04-12),Table 1.
For adhesive-set tile applications,refer to Section 5.6.4 herein.
For nail-on tile systems over Polystick MTS,battens are required for loading/staging of the tile.
For nail-on tile systems over Polystick MTS PLUS:
➢ Battens are required for loading/staging of lugged tile regardless of slope.
➢ Battens are required for loading/staging of flat tile at slopes in excess of 5:12.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R22
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-R26
Polyglass USA,Inc. Revision 22:03/13/2017
Page 12 of 14
,ma l TRINITY ERD
6.4.4 Two(2)Ply Underlayment SVstems:
Polystick MTS or MTS PLUS followed by Polystick MTS,MTS PLUS,TU P,TU Plus,TU Max,Tile Pro,MU-X or Polyflex
SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with
the top-layer material. This is not a requirement,but is allowable if a 2-ply underlayment system is desired.
Polystick MTS PLUS followed by Polystick TU P,TU Plus,TU Max,Tile Pro or Polyflex SAP is allowable for use under
foam-on tile systems. Limits of use are those associated with the top-layer material. This is not a requirement, but is
allowable if a 2-ply underlayment system is desired.
6.5 Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR:
6.5.1 Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be installed in compliance with current Polyglass published
installation requirements. For use in tile applications:
✓ Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single
Ply System"from FRSA/TRI April 2012(04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the "Two Ply System"from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in the"Single Ply
System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G FR is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in the"Single
Ply System"from FRSA/TRI April 2012(04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the"Two Ply System"from FRSA/TRI April 2012(04-12) beneath mechanically fastened tile
roof systems.
6.5.2 For hot-asphalt-applications, Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR shall be fully asphalt-applied to the
substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end-laps minimum 6-inch wide, off-set
minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt
with asphalt extending approximately 3/8-inch beyond the lap edge.
6.6 Polyflex G or Polyflex G FR:
6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements.
For use in tile applications:
✓ Polyflex G is for use as an alternate to the Heat Applied "Cap Sheet" in the"Two Ply System"from FRSA/TRI April
2012(04-12) beneath mechanically fastened or adhered tile roof systems(Base Sheet Limited per 5.6.3).
✓ Polyflex G FR is for use as an alternate to the Heat Applied applied "Cap Sheet" in the `Two Ply System" from
FRSA/TRI April 2012(04-12)beneath mechanically fastened tile roof systems(Base Sheet Limited per 5.6.3).
6.6.2 Polyflex G or Polyflex G FR shall be fully torch-applied to the substrates noted in Section 5.6. Side laps shall be
minimum 3-inch and end-laps minimum 6-inch wide, off-set minimum 3 feet from course to course. Side and end
laps shall be fully heat-welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap
edge.
Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-R22
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-R26
Polyglass USA,Inc. Revision 22:03/13/2017
Page 13 of 14
U
TRINITY ERD
6.7 Tile Staging:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to
Polyglass published requirements for tile staging.
6.7.2 Battens and/or Counter-battens, as required by the tile manufacturer and FRSA/TRI April 2012(04-12) must be used
j on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nail-
boards,to prevent tile sliding and/or damage to the underlayment during the loading process.
6.7.3 For nail-on tile systems over Polystick MTS,battens are required for loading/staging of the tile.
6.7.4 For nail-on tile systems over Polystick MTS PLUS:
➢ Battens are required for loading/staging of lugged tile regardless.of slope.
➢ Battens are required for loading/staging of flat tile at slopes in excess of 5:12.
6.7.5 The minimum cure time after installation of self-adhering membranes and before loading of roofing tiles is forty-eight
(48)hours.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C.Rule 61G20-3 OA requirements.
9. QUALITY ASSURANCE ENTITY:
UL, LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R22
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-R26
Polyglass USA,Inc. Revision 22:03/13/2017
Page 14 of 14