Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 4 Business & Professional Regulation a I om BCIS Home ; Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff SCIS Site Map Links Search b' r Product Approval RECEIVED ,� USER:Public User s'S - Product Approval Menu>Product or ApplicD7E2 plication Deta JAN N 1 n 2018 FL# 63-R2 J H IV b Application Typeon LST. Lucie County, Permitting Code Version Application Statusved ed by DBPR.Approvals by DBPR shall be reviewed and ratified POC and/or the Commission if necessary. Comments Archived Product Manufacturer Masonite International Address/Phone/Email 1955 Powis Road West Chicago,IL 60185 (800)663-3667 sschreiber@masonite.com Authorized Signature Steve Schreiber sschreiber@masonite.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year ASTM E1886 2005 ASTM E1996 2009 ASTM E330 2002 TAS 202 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 12/01/2017 Date Validated 12/04/2017 Date Pending FBC Approval https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs3 M6m9%2fK8XPO... 1/16/2018 Florida Building Code Online Page 3 of 4 22363.6 Fiberglass Side-Hinged Door Unit 6'-8"Impact Glazed I/S or O/S Single or Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL22363 R2 C CAC NI013717_05 R1 cif Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 05/31/2021 Design Pressure: +50/-50 Installation Instructions Other: Evaluated for use in locations adhering to the FL22363 R2 II FL0195.pdf Florida Building Code,excluding the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do exceed the Created by Independent Third Party: design pressures listed. 12'-0"x 6'-8"max nominal size. Evaluation Reports Hurricane protective system not required in the Wind Borne FL22363 R2 AE 514008A.Ddf Debris Region. See DWG-MA-WL0195 for details. FL22363 R2 AE 514012A.odf Created by Independent Third Party: Yes 22363.7 Fiberglass Side-Hinged Door Unit 8'-0"Opaque I/S Single Door Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22363 R2 C CAC NI013717.18-Rl.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 05/31/2021 Design Pressure: +60/-65 Installation Instructions Other: Evaluated for use in locations adhering to the FL22363 R2 II FL0188.1)df Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do exceed the Created by Independent Third Party: design pressures listed. 3'-0"x 8'-0"max nominal size. Evaluation Reports Hurricane protective system required in HVHZ, but not in the FL22363 R2 AE 514009A.pdf Wind Borne Debris Region. See DWG-MA-WL0188 for FL22363 R2 AE 514013A.pdf details. Created by Independent Third Party: Yes 22363.8 Fiberglass Side-Hinged Door Unit 8'-0"Opaque O/S Single Door Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22363 R2 C CAC NI013717.18-R1.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 05/31/2021 Design Pressure: +60/-60 Installation Instructions Other: Evaluated for use in locations adhering to the FL22363 R2 II FL0188.pdf Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do exceed the Created by Independent Third Party: design pressures listed. 3'-0"x 8'-0"max nominal size. Evaluation Reports Hurricane protective system required in HVHZ,but not in the FL22363 R2 AE 514009A.pdf Wind Borne Debris Region. See DWG-MA-WL0188 for FL22363 R2 AE 514013A.pdf details. I Created by Independent Third Party: Yes 22363.9 Fiberglass Side-Hinged Door Unit 8'-0"Opaque I/S or O/S Single or Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22363 R2 C CAC NI013717.18-R1.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 05/31/2021 Design Pressure: +50/-50 Installation Instructions Other: Evaluated for use in locations adhering to the FL22363 R2 II FL0188.pdf Florida Building Code, including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do exceed the Created by Independent Third Party: design pressures listed. 12'-0"x 8'-0"max nominal size. Evaluation Reports Hurricane protective system required in HVHZ, but not in the FL22363 R2 AE 514007A.Ddf Wind Borne Debris Region.See DWG-MA-WL0188 for FL22363 R2 AE 514011A.0 details. Created by Independent Third Party: Yes 22363.10 Fiberglass Side-Hinged Door Unit 8'-0"Glazed I/S or O/S Single or Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22363 R2 C CAC NI013717 08-R1 pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 05/31/2021 Design Pressure: +40/-40 Installation Instructions Other: Evaluated for use in locations adhering to the FL22363 R2 II FL0190.pdf Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zane,and where pressure requirements do exceed the Created by Independent Third Party: design pressures listed. 12'-0"x 8'-0"max nominal size. Evaluation Reports Hurricane protective system required in HVHZ and the Wind FL22363 R2 AE 514007A.pdf Borne Debris Region. See DWG-MA-WL0190 for details. FL22363 R2 AE 514011A.pdf Created by Independent Third Party: Yes 22363.11 Fiberglass Side-Hinged Door Unit 8'-0"Impact Glazed I/S Single or Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL22363 R2 C CAC N1013717.09-Ri.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 05/31/2021 https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs3 M6m9%2tK8XPO... 1/16/2018 Florida Building Code Online Page 4 of 4 Design Pressure: +40/-45 Installation Instructions Other: Evaluated for use in locations adhering to the FL22363 R2 II FL0196.pdf Florida Building Code,excluding the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do exceed the Created by Independent Third Party: design pressures listed. 12'-0"x 8'-0"max nominal size. Evaluation Reports Hurricane protective system not required in the Wind Borne FL22363 R2 AE 514007A.Ddf Debris Region. See DWG-MA-WL0196 for details. FL22363 R2 AE 514011A.odf Created by Independent Third Party: Yes 22363.12 Fiberglass Side-Hinged Door Unit 8'-0"Impact Glazed O/S Single or Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL22363 R2 C CAC NI013717.09-Rl.Ddf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 05/31/2021 Design Pressure: +45/-40 Installation Instructions Other: Evaluated for use in locations adhering to the FL22363 R2 II FL0196.1)df Florida Building Code,excluding the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do exceed the Created by Independent Third Party: design pressures listed. 12'-0"x 8'-0"max nominal size. Evaluation Reports Hurricane protective system not required in the Wind Borne FL22363 R2 AE 514007A.Ddf Debris Region.See DWG-MA-WL0196 for details. FL22363 R2 AE 514011A.Ddf Created by Independent Third Party: Yes 22363.13 HPC Fiberglass Side-Hinged Door 8'-0"Glazed I/S or O/S Single or Double Door w/or w/o Unit Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22363 R2 C CAC NI013717.07-Rl.Ddf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 05/31/2021 Design Pressure: +47/-47 Installation Instructions Other: Evaluated for use in locations adhering to the FL22363 R2 II FL0192.odf Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do exceed the Created by Independent Third Party: design pressures listed. 12'-0"x 8'-0"max nominal size. Evaluation Reports Hurricane protective system required in HVHZ and in the FL22363 R2 AE 514007A.odf Wind Borne Debris Region. Door top rails stamped"HPC". FL22363 R2 AE 514011A.Ddf See DWG-MA-WL0192 for details. Created by Independent Third Party: Yes 22363.14 HPC Fiberglass Side-Hinged Door 6'-8"Glazed I/S or O/S Single or Double Door w/or w/o Unit Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22363 R2 C CAC NI013717.02-Rl.Ddf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 05/31/2021 Design Pressure: +50/-50 Installation Instructions Other: Evaluated for use in locations adhering to the FL22363 R2 II FLO191.Ddf Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do exceed the Created by Independent Third Party: design pressures listed. 12'-0"x 6'-8"max nominal size. Evaluation Reports Hurricane protective system required in HVHZ and the Wind FL22363 R2 AE 514008A.Ddf Borne Debris Region. Door top rails stamped"HPC". See FL22363 R2 AE 514012A.Ddf DWG-MA-WL0191 for details. I Created by Independent Third Party: Yes Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395."Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ® aC' Credit Card Safe https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQWtDgs3 M6m9%2fK8XPO... 1/16/2018 Do 1111 M/�SONITC. --- 149•IIAX. ovERALL FRAME WIDTH O IMPACT GLAZED FIBERGLASS DOOR UNIT 2 D.L.O. PANEL " MAH. 37.5" MAH c) D. .O. PANEL WIDTH WIDTH J 6-8"DOUBLE DOOR WITH/WITHOUT SIDELITES w/AsrRACAL FRAME �O GENERAL NOTES W O Q 1. EVALUATED FOR USE IN LOCATIONS ADHERING TO THE FLORIDA BUILDING CODE AND WHERE PRESSURE Z U REQUIREMENTS AS DETERMINED BY ASCE 7, MINIMUM S DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, LL u() DOES NOT EXCEED THE DESIGN PRESSURES LISTED. h F' 'r) 2. WHEN INSTALLED IN THE HIGH VELOCITY HURRICANE ZONE (HVHZ), 0 HURRICANE PROTECTIVE SYSTEM (SHUTTERS) IS REQUIRED, iXs n ¢ r W 3. WHEN INSTALLED IN THE WIND-BORNE DEBRIS REGION, � ¢p e EXCLUDING THE HIGH VELOCITY HURRICANE ZONE (FIVHZ), -i HURRICANE PROTECTIVE SYSTEM IS NOT REQUIRED. W p 4. POLYURETHANE CORE FLAME SPREAD INDEX OF 50 AND SMOKE DEVELOPED INDEX OF 60 PER ASTM EB4. cc 5. PLASTICS TESTING: TEST DESCRIPTION DESIGNATION FACING LITE FRAME W SELF IGNITION TEMP ASTM D1929 752 'F > 650 'F 842'F > 650'F RATE OF BURNING ASTM 2635 0.56 IN MIN 1.28 IN MIN n S MOKE DENSITY ASTM D2843 53.4X 70.2% `O m TENSILE STRENGTH- ASTM D638 3.2% DIFF 1.8% DIFF 6. PLASTICS TESTING OF WORLDWIDE COMPOSITE FRAME (WHERE USED): r +/ TEST DESCRIPTION DESIGNATION RESULTS o SELF IGNITION TEMP ASTM D7929 779 ''1> 850 'F g RATE OF BURNING ASTM D635 0.0 IN MIN DOUBLE DOOR UNIT W/SIDELIrES a SMOKE DENSITY ASTM D2843 39.0% TENSILE STRENGTH- ASTM D638 3.6R DIFF 3 m ATH • COMPARATIVE TENSILE STRENGTH AFTER WEERING N 4500 HOURS XENON ARC METHOD 1 r O to • • • • I � SINGLE DOOR UN R DOUBLE DOOR UNIT SINGLE DOOR UNR SINGLE DOOR LIN f7 SINGLE F DOOR UNIT WI-14DELffES DOUBLE DOOR UNIT W/SIDFIJTES r Q WITH SIDELITE WITH SIDELITE p Ad*dImtoWA1 WHERE WATER INFILTRATION PERFORMANCE IS DESIGN PRESSURE RATING REQUIRED TO BE 15% OF DESIGN PRESSURE SND. �ze CONFIG MAX WIDTH INSWING OUTSWING INSWING BUMPER 0 5 Z-SERIES 0 S T4 0 S HIGH DAM 0 S <z �. X 37.5 +50.0 -50.0 +50.0 -50.0 JNN A 125.Dii 25.0 +40.0 -40.0 +50.0 -50.0 +50.0 -50.0 XX 74 +50.0 -50.0 +50.0 -50.0 A . 25.0 +40 -40.0 +50.0 -50.0 +50.0 -50.0 OX orXO 75 +50.0 -50.0 +50.0 -50.0 A . 25.0 +40.0 -40.0 +50.0 -50.0 +50.0 -500 4 26 1OXO 112.5 +50.0 -50.0 +50.0 -50.0 A . 25.0 +40.0 ✓Y OXXO 149 +50.0 -50.0 +50.0 -50.0 A +25.0 -25.0 +40.0 -40.0 +50.0 -50.0 +50.0 -50.0 SJ scALE N.T.S. TABLE OF COMFITS orc.BY: SINS 4JAN�1��®RING DESCRIPTION KURT BALTHAZOR DPAMNG NO.: au m. ELEVATIONS & G N S FLORIDA P.E.LOCATIONS & DETAILS 156533 OWC-MA-FL0195-17NCHORING LOCATIONS & DETAILS sHF>=r_L OF 3 Lr) Qo00� 6' SEE DETAIL 3„ ,E. 3to � 3. Q 3" — 3' 3" 3" c J 6" — 6.6. 6 f U 6' �W �2p U 0 U Z f- a a SEE DETAIL (n a. 1n'D' — Q 3 y � � SGEE DETAIL — A — W w SEE DETAIL e W — .C. B � C A n O g in G H n H 6" 6' I 6,3 i0 p m _ 6' y � I I I I I I I I 3• _ 3" t Ir Ir 6" a SEE DETAIL 6 #8 x 2" "F' 3 m ASTRAGAL RETAINER BOLT HOLE — #8 x 2 #10 x 5/8" MUST BE DRILLED OUGH THE THRESHOLD &T NT 0 THE 6ji;rSTRUCTURE DEEP ENOUGH #8 x 2" #70 x 5/8" #10 x 1" DETAIL "E" ASTRAGAL FOR A 1.375' THROW o In #10 x 2_1/2" ATTACH ASTRAGAL RETAINER BOLT DETAIL "F" ASTRAGAL w o #10 x 1" STRIKE PLATE TO FRAME M*Aintowm a v, #10 x 5/8" AS SHOWN. a �Ipfwa9mNo:. DETAIL "C" qe IedB/. DETAIL "D• Dale n 0.962" also Hur mswenom xmumc wstxr M121'tiFa snuwnpm ORCRAML WSM N nm srnnc O+a 1s-uor.lq (Q U o.ao'srrwc("w is-imi.i» (ov 1.375" 0.124•Hrwr sfrwlvv oen .azo Mr. &ler«w smoanoEa�� au•Tor. T T 11r•h ,/r MR INSWING THRESHOLD BUMPER 0/S THRESHOLD , a z ooN sas ���`': 0024 sse oo"sn �� 0024 saa � DATE 4126117 r>®oe , , „tee 1.482" 1.75"E��l 1.437" TYPICALAZWG D ff�m ET❑ ALrERN4TE GLa71NG OETAfI SCALE N.T.S. 1 T T IMPACT RATED •a S IMPACT RATED G A S °wa'RY` Sws cw.fN: Z—SERIES 0/S THRESHOLD HIGH DAM 0/S THRESHOLD 14 O/S THRESHOLD Jew' OWO—MA—F70195-17 SHEET 2 or 3 SEE SHTAI2 3" 6' _ 6' 3' -6 _ Q Q 3' 6' �- � 3'-1 1-3 v I p ...1 Q t- 6" 6• 6" 6. I I I I O ( I 6" 10 2 cn O N — _ W o Q w < W Z a SEE DETAIL - _ a t u)U } "D' SHT. 2 ur Z h- y O -L) Lu SEE DETAIL �Z— D j "C" SHT. 2 A w 1n w B A A G N G H 9 i 6' 6" I Ems•, r6. C - I I 11 11 I1 II Ing 3" fIas Ad*dumlDNAIA 3» 3" 3.6 6" f—3' j SEE DETAIL 3 Cel maiimNO_�(Tnitiil4 "F' SHT. 2 6" 6" o za Reriewed_By. 6" HARDWARE SCHEDULE a a ATTACHMENT DETAIL 1. KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND 3:m SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED 1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED, AT 5-1/2" CENTERLINE. SIGNED AND SEALED BY ROBERTO LOMAS, PE (FLORIDA #62514) WITH THE LOWEST (LEAST) 1�il5 ,• 2. 4" X 4" FULL MORTISE BUTT HINGES. FASTENER RATING FROM THE DIFFERENT FASTENERS —MAX 1"X1/2" CORRUGATED #lOX2" WOOD SCREW BEING CONSIDERED FOR USE. JAMB, HEAD, AND SHIM 3" FROM EACH END 6" FROM EACH END v 1.25" AND 7" OC AND 12" OC THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE CL—� I- MIN > x z #10 WOOD SCREWS, 1/4" TAPCONS, AND #10 TEK SCREWS. _ 0.25" a A PHYSICAL SHIM MUST BE PLACED IN SHIM SPACE AT EACH "` SHIMMAX ACRYLICLA d ANCHOR LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2". CIL I CAULKLK - I_ TEX WOOD SCREW EDGE DISTANCE MIN 3/4". TEK SCREW EDGE TYPICAL MASONRY � ACRYLIC � r DISTANCE MIN 1/2". ANCHOR INSTALLATION "°S CLA AULK CL w 2. ANCHORING INTO STEEL STRUCTURE MUST BE SUFFICIENT TO 1X BUCK MASONRY COMBINATION WOOD COMBINATION WOOD ACHIEVE 3 THREADS MINIMUM BEYOND STEEL INTERIOR SURFACE. 150" ANCHOR INSTALLATION MULLION (BOXED) MULLION (BOXED) 3. THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM MIN 0.25'MAX (3) 10X2-1/2' (4)�{10X2-1/2" a z ANSI/AF&PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT SHIM wOEADCHSCREWS W EACH RE S OF 1-1/2" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE CL_� I� DATc: 2s ND MINIMUM EMBEDMENT OF 1-1/4". 4261t1 7 a+-" a SCALE: 4. WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO DWG.BY: Sws TRANSFER LOADS TO STRUCTURE. TYPICAL WOOD BUCK s °® D"K e'. 5. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 155 LBS. ANCHOR INSTALLATION DNAWING ND.: INTEGRAL WOOD INTEGRAL WW DWG-MA-FL 195-17 MULLION (CHS) MULLION (CHS) SHEF 3 -- 3