Loading...
HomeMy WebLinkAboutEngineering W1 NDOW & DOOR OPENING INFORMATION A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Comer Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING SHUTTERS NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF DIMENSIONS MULLION REQ Y/N SIZE REQ Y/N/NA 1 End Door V Lami IG FL 15210.4 75 75 38.2 -49.9 37.5 x 81 3 7x81 No No 2 Int Window La-UG FL15780.8 55 65 39.9 -43.3 14,,76.5 34x47 No No -- _ - 3--- -Int- -- FL15780:8-- 55-- -= =65 --39.8-----4-3v - _- --35x47--- -=No - --No----- Window-- -7[8°L=i-1G__ 54 z 76.5 - 4 Int Window 7/e"Lai IG FL15780.8 55 65 39.9 -43.3 54x76.5 34x47 No No - - - ---- - --- --- 5 End Window 7e"IamiIG FL15780.8 55 65 39.1 -51.7 - 54x76.5 35x61 N- No -- 6 Int Door 1"Ann FL15210.6 75 75 36.6 -40.0 74 x 81 72x79 No No 7 Int Window 78"Ian"IG FL15780.8 55 65 39.1 -42.5 54x76.5 35x61 No No 8 Int Window 7/1"La-"G FL15780.8 55 65 39.1 -42.5 54x76.5 35x61 No No 9 End Window 78'LamilG FL15780.8 55 65 39.1 -51.7 54x76.5 35x61 No No 10 Int Window 711"Land IG FL15780.8 55 65 39.1 -42.5 54776.5 35x61 No No 11 Int Door 1"Ann FL15210.4 75 75 38.7 -42.1 37.5x11 31x80 No No 12 Int Window 7e La-"G FL15781.11 55 60 40.2 -43.6 73 x 63 24x26 YES No 13 Int Window 78"Lam1IG FL15780.8 55 65 40.2 -43.6 54 x 76.5 28x51 No No 14 Int Window 78 LanulG FL15780.8 55 65 40.2 -43.6 54x76.5 3505 No No 15 End WINDOW 1"LAMIIG FL13010.4 55 55 40.2 -53.8 48 x 72 3404 No No 16 End DOOR NONE FL15210.1 75 75 38.6 -50.6 37.5x11 33x80 No No 17 End wlrmow 1"LAMIIG FL13010.4 55 55 40.2 -53.8 48 x 72 22x21 No No 18 Int Window lie"La-i IG FL15780.8 55 65 40.2 -43.6 54 x 76.5 22x52 No No 19 Int Window 7'8°La" FL15780.8 55 65 40.2 -43.6 54 x 76.5 22x52 No No 20 Int Window 711"Lar" IG FL15780.8 55 65 40.2 -43.6 54 x 76.5 22x52 No No 21 End Window 7/8"Lami1G FL6890.1 67.5 67.5 40.1 -53.7 3702 28x52 No No 22 Int I Window 7/8""' 1 IG FL15780.8 55 65 40.1 -43.5 54 x 76.5 28x52 No No WINDOW & DOOR OPENING INFORMATION A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Comer Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING SHUTTERS NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF DIMENSIONS MULLION REQ Y/N SIZE REQ Y/N/NA 23 End Window 7/8"Lami1G FL6890.1 67.5 67.5 40.2 -53.8 37X72 3304 No No 24 End Window 78"`umi1G FL15780.8 55 65 40.2 -53.8 54x76.5 3305 No No 25- 54-k n = Window—-78°`�""`G=-F-L'1-5-!--90;--8- S5- f =-65—=" 40:2= 5&-&= —33x34= FARAD �[' RS tY l� "Building Our Ouali Re` utatior One Customer At A Time" SCC131150472 Property Information Buildinlg Information Owner: DAVID MOORE Wind Zone: 170 MPH. Address: 10499 MULLER RD Exposure Category: C FORT PIERCE,FL 34945 Minimum Building Dimension: 20 ft. Mean Roof Heigl t: j 20 ft. Risk Category: ; H IL Design Pressure Calculation's I Opemng Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft)! Pressure(ps) Pressure(psf) 1 End 37 81 7 38.2 -49.9 2 Int 34 47 7 I 39.9 -43.3 3 Int 35 47 7 I 39.8 -43.2 4 Int 34 47 7 39:9 43.3 5 End 35 61 7 I 39 l -51.7 6 Int 72 79 7 36.6 40.0 7 Int 35 61 7 39.1 -42.5 8 Int 35 61 7 + 391 -42.5 9 End 35 61 7 1 39,11 -51.7 10 Int 35 61 7 39'4 -42.5 111 Int 31 80 7 38.7 -42.1 12 Int 24 26 7 40'2 -43.6 113 Int 28 51 7 I 40!2 43.6 14 Int 35 35 7 40:2 -43.6 15 End 34 34 7 40.2 -53.8 j 16 End 33 80 7 '. 38;6 -50.6 !17 End 22 21 7 40;2 -53.8 18 Int 22 527 402 -43.6 19 Int 22 52 7 I 40:2 -43.6 20 Int 22 52 7 40j2 -43.6 21 End 28 52 7 40:1 -53.7 22 Int 28 52 7 I 40!1 -43.5 23 End 33 34 7 40.2 -53.8 I ' 1 Page 1 of 2 i r I I P EXTE,.RU11 ?R-S ARADI.1--ISE "Bu ilding Building Our Quality Reputation:. One Customer At A Time SCC131150472 Property Information BU:ildin' Information Owner: DAVID MOORE Wind Zone: 170 MPH. Address: 10499 MULLER RD Exposure Category: I C FORT PIERCE,FL 34945 Minimum Building Dimension: 20 ft. Mean Roof Heiglit: ! 20 ft. Risk Category:LL II Design Pressure Calculation's IF'Np:b ing Location Device Device Device Max Positive Max Negative er Zone Width(in) JHeight(in) Elevation(ft)i Pressure;(psh Pressure(psfl 124 End 33 35 7 1 40.2 -53.8 125 End 33 34 7 j 4 0.2- -53.8 26 End 33 34 7 40.2 -53.8 I I I I i I i I i ' I I I I i i I i I I 1 I ' I ' I ; I Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.Sth Edition(2014)Florida Building Code. Page 2 of 2 I I . 1