Loading...
HomeMy WebLinkAboutNotice of Acceptance MIAMI-RADE COUNTY MIAMI- am* ;PRODUCT CONTROL SECTION mmm I : 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) , Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE(NOA) www.miamidade.gov/economy GAF 11 Campus Drive Parsippany,NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The ;I . Pr Control documentation submitted has been reviewed and accepted by Miami Dade Coun�y RER-Product Ct COn 01 Section to be used in Miami Dade County and other areas where allowed by the Authority Hav' ing Jurisdiction(Al-U). Titus NOA shall not be valid after the expiration date stated below. The Mi -Dadd County Product Control S6ction (in Miami Dade County) and/or the AHJ (in areas other than Miami bade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AAJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. 1 REi,reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Cdntrol Sectiori,that this product or material faits to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Timberline HD®,Timberline'Natural Shadow®,Timberline*American Harvest,and FortitudOm Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,City, state and following I I statement: "Miami-Dade County Product Control Approved unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change I I I inthe applicable building code negatively affecting the performance of this product. ]LIERMINATION of this NOA will occur after the expiration date or if there has been revision or change in the iriaterials,use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, I ... I i for sales,advertising or any other purposes shall automatically terminate this N Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,I Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is'displayed,then it shall be done in!its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by theiiianufadurer or its distributors and shall be available for inspection at the job site at the request of the Building Offtial. This NOA renews and revises NOA# 14-1022.20 and consists of pages I through 6. The submitted documentation was reviewed by Alex Tigera. NOA No.: 16-0811.11 MIAMI•DAD;COU G Expiration Date:02/21/22 Approval Date: 02/09/17 Page 1 of 6 ROOFING ASSEMBLY APPRovAL F ' Category .Roofing Sub-Category: Asphalt Shingles I Materials: Laminate I Deck Ty pe• Wood ! ! I SCOPE This approves GAF Timberline HD's,Timberlines'Natural Shadow',Timberline American®Harvest®,and FortitudeTM Shingles as manufactured by GAF as described in this Notice of Acceptaiace. i RODUCT DESCRIPTION I' Product Dimensions Test i Product Description Specifications GAF Timberline HDA 131/4"x 39 /; TAS 110 Fiberglass reinforced heavy weight asphalt Aianufacturing roof shingle,with a laminate profile Locations#1,2,3,4,5,6,7 GAF Timberline Natural - 13 1/4"x 39 W' TAS 110 Fiberglass reinforced heavy weight asphalt Shadow" roof shingle,with a 1{urinate profile Manufacturing ! Locations#1,2,3,4,5,6,7 I GAF Timberline®American 13 1/4"x 39 3/8' TAS 110 Fiberglass reiri'orcedi'heavy weight asphalt Harvest' roof shiingle,with a 1!aminate profile Manufacturing Locations#2,4,5,6 3 ! GAF FortitudeT"M 131/4"x393/; TAS 110 Fiberglass reinforced heavy weight asphalt Manufacturing roof shingle,with a laminate profile Locations#1,4 MANUFACTURING LOCATION I !' I. 4 1.� Tampa,FL 2. Michigan City,IN i i 3. Baltimore,MD 4. Myerstown,PA i I 5. Ennis,TX 6.- Tuscaloosa,AL 7.., Dallas,TX NOA.No.: 16-0811.11 MLAMiaADacau�rcx Expiration Date: 02/21/22 ! ; 'Approval Date:02/09/17 Page 2 of 6 I ; � EVIDENCE SUBMITTED Test Altney Test Identifier Test Nanie/Reyort Date Underwriters LaboratoriesLLC ASTM D34627 7 . 101 , 07/25/16 Underwriters Laboratories,Inc. ASTM D3462 I I CA48924 10/24/11 Underwriters Laboratories,Inc ASTM D3462 IOCA21994 , 04/22/11 Underwriters Laboratories,Inc ASTM D3462 IOCA28717 07/26/11 Underwriters Laboratories,Inc. ASTM D3462 i I 05CA47541 11/10/06 Underwriters Laboratories,Inc. ASTM D3462 106CA3i580 11/30/06 PRI Asphalt Technologies, Inc. ASTM D3462 GAM-101,02-02 11/02/05 Underwriters Laboratories,Inc, ASTM D3462 i06NK05159 08/09/06 PFI Asphalt Technologies,Inc. ASTM D3462 GAF-098-,02-02 11/08/05 Underwriters Laboratories,Inc. ASTM D3462 kNK41 08/11/02 Underwriters Laboratories,Inc. ASTM D3462 103NK26444 10/17/03 Center for Applied Engineering ASTM D3462 257989 05/13/97 Underwriters Laboratories,Inc. TAS 107 )INK45803 04/13/94 Underwriters Laboratories,Inc. TAS 107 i06NK05159 08/09/06 Underwriters Laboratories,Inc. TAS 107 4NK04273 02/20/04 Underwriters Laboratories,Inc. TAS 107 015CA42,840 11111105 Underwriters Laboratories,Inc. TAS 107 !02NK41811 11/11/02 Underwriters Laboratories,Inc. TAS 107 03CA35d I I 11111209 10/17/03 Underwriters Laboratories,Inc. TAS 1076'WO 08/30/04 Cen'ter for Applied Engineering TAS 100 257989 04/01/97 PRi Asphalt Technologies,Inc. TAS 100 GAF-044202-01 01/13/04 PRi Asphalt Technologies, Inc. TAS 100 6XF-098-02-01 11/08/05 PRI Asphalt Technologies, Inc. TAS 100 dAF-IOi-',!02-0I' 11/09/05 PRi Asphalt Technologies,Inc. TAS 100 GAF-116-,02-0i 03/23/06 PRi Asphalt Technologies,Inc. TAS-100 ELK-083-02-01 10/16/02 ELK-0847'02-01 10/15/02 ELK-W7',02-01 10/14/02 ELK-086-02-01 10/24/02 ELK-087-02-01 10/21/02 ELK-088-02-01 10/16/02 ELK-107-02-01 10/09/03 ELK-108-62-01 10/09/03 ELK-109-02-01 10/09/03 LIIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Apprbved Ro I ofing,Materials Directory for II fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. MAMI-DADECOU NOA No.: 16-0811.11 Expiration Date:02/21/22 P—M.am) Approval Date: 02109/17 Page 3 of 6 I II � I � I H I I INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions.] j 4. Exposure and course layout shall be in compliance with Detail'A', attached. 5. Nailing shallbe in compliance with Detail'B', attached. LABELING I Shingles shall bear the imprint or identifiable marking of the manufactttr"er's nameof logo, city and state of manufacturing facility, and following statement. Miami-Dade County Product Control!Approved" or the Miami-Dade County Product Control Seal as shown below. I QMIAMMI-D�ADE COUNTY I' { I , I i BUILDING PERMIT REQUIREMENTS i i 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. i I' 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. E i { i i NOA No.: 16-0811.11 MIAMI•DADE COUNTY ••• , 1'Expiration Date: 02/21/22 ! 1 Approval Date: 02/09/17 Page 4 of 6 i,{ ! Ii DETAIL COURSE LAYOUT DECK FULL IJ f 5th 17" OFF 4th 11"OFF 3rd i. 6" OFF 2nd FULL 1st II i NOA No.: 16-0811.11 MIAMUDADECOUIM Expiration Date: 02/21/22 Approval Date:02/09/17 Page 5 of 6 i I I I i ' DETAIL B OVERALL DIMENSIONS AND NAMING PATTERN I � i 1 (IM) 14-1/Z'-17-112" 14-1t2"-17111/2" ;.. (363-445mm) (368-445mm) I e ail guide line ! 6-1/2" 9-1/2" 6-112"-9-112';' 5-314~-6-v4' 13-114 t��_�,m>� (146rnm-159mm) (33Tmm) 2-1 -- --� �— -♦- "— - ; from bottom of shingle Vs-er elf seal I i adhesive i on back ENHANCED NAILING PATTERN - six nails per shingle, r •required by some local codes and required for enhanced wind coverage on certain products.! See limited warranty for details. f These shingles MUST be nailed a nominal 6"(152mrn)from bottom of of shingle, above the-cut outs, as shown. Nails must not tie exposed. I • • s ' END OF THIS ACCEPTANCE I E li I , it 1 ? � I I II i I ; II `II I � I - I VIII ; ! I i I , E NOA No.: 16-0811.11 hf1AMt-DADECOU tm I 's I Expiration Date:02/21/22 Approval Date:02/04/17 I � I Page 6 of 6 I li I