HomeMy WebLinkAboutDrawing 2 36" X 80" 1 36" X 80" --------------------------------------------------------------- ------------------------------------------------------------- REPLACE DOORS IN 2 OPENINGS ONLY. NEW DOORS TO BE IMPACT RESISTANT- HURRICANE SHUTTERS NOT REQUIRED. OPENING PRODUCT DESIGN OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS NO. WDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG. 136 80 20.00 4 36.1 -39.3 FL22378.5 55.0 -55.0 KITCHEN-LSMI 2 1 36 1 80 20.00 5 36.1 -47.2 FL22378.5 55.0 -55.0 BEDROOM-LSMI REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS. NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS. ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS. SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES MEAN ROOF HEIGHT= 11 FT 3 IN TOMLINSON RESIDENCE 3189 LINDA VISTA AVENUE DOOR REPLACEMENT PLAN FORT PIERCE, FLORIDA