HomeMy WebLinkAboutWind Load Calculation Property Information JF- Building Information Owner: Shimeld Wind Zone: 160 MPH. r Td s 33 Arboles del Norte Exposure Category: B Ft Pierce,Fl 34951 Minimum Building Dimension: 24 ft. Mean Roof Height: 15 ft. JV Risk Category: 11 Design Pressure Calculations =penin Location Dei De\ice Device Max Positive Negative Number 'IF IF Max1 11 Nb egr Zone 1—width(in) Height(in7) 1 Elevation(ft) Pressure(pso _LPressure(psf) I End 108 83 7 28.6 -35.8 ................. .......... ......................... ..................... 2 End 106 83 7 28.7 -35.8 .............- -......--------- ................... .................... ............. .......... 3 Int 106 83 7 28.7 -31.4 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page I of 1