Loading...
HomeMy WebLinkAboutProduct Approval 1/19/2018 Florida Building Code Online BCIS Home Log In User Registration I Hot Topic Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links 1 Search Florida 3a= Product Approval USER:Public User Rom 1,r Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL10124-1120 Application Type Revision Code Version 2017 Application Status Approved Comments Archived I71 Product Manufacturer GAF Address/Phone/Email 1 Campus Drive Parisppany,NJ 07054 (800)766-3411 mstieh@gaf.com Authorized Signature Robert Nieminen lindareith@trinityerd.com Technical Representative William Broussard Address/Phone/Email 1 Campus Drive Parsippany,NJ 07054 (800)766-3411 TechnicalQuestionsGAF@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer u Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/20/2018 Validated By John W.Knezevich,PE Z Validation Checklist-Hardcopy Received Certificate of Independence FI-10124 R20 COI 2017 01 COI Nieminen.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2015 ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2011 . TAS 107 1995 Equivalence of Product Standards Certified By https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquracBeVCbdMQNZD6Zesy3BoOyLwXhMdCmfpylEOlvyCAp/p3dp/o3d 1/2 1/19/2018 Florida Building Code Online Sections from the Code Product Approval Method Method 1 Option D Date Submitted 09/20/2017 Date Validated 09/27/2017 Date Pending FBC Approval 09/28/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 10124.1 GAF Asphalt Roof Shingles Fiberglass reinforced 3-tab,laminated,5-tab and hip/ridge asphalt shingles Limits of Use Installation Instructions Approved for use in HVHZ:No FL10124 R20 II 2017 09 FINAL ER GAF Asphalt Approved for use outside HVHZ:Yes Shingles FL10124-1120.0f Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure:N/A Created by Independent Third Party:Yes Other:Refer to ER,Section 5. i Evaluation Reports FL10124 R20 AE 2017 09 FINAL ER GAF Asphalt Shingles FL10124-R20.odf Created by Independent Third Party:Yes Back Next Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an WEED employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click here. Product Approval Accepts: Credit Card https:/Iwww.floddabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquracBeVCbdMONZD6Zesy3BoOyLwXhMdCmfpylEOlvyCA*/`3d`/o3d 2/2 i i EXTERIOR RESEARCH&DESIGN,LLC. Certificate of Authorization#9503 QOTRRINITYIERD353 CHRISTIA0 ORD, UNIT#13 CT 06478 (203)262-9245 EVALUATION REPORT GAF Evaluation Report 01506.01.08-1122 1 Campus Drive F1.10124-1120 Parsippany,NJ 07054 Date of Issuance:01/03/2008 PP Yr (800)766-3411 Revision 22:09/20/2017 SCOPE: This Evaluation Report is issued under Rule 611320-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the a Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: GAF Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT:The Evaluation Report number preceded by the words "Trinityl ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: ggtitlrn,r, — 139""e'n.c0, Robert J.M.Nieminen,P.E. �����`��;��`�•���{T: ijj..........ps`'� The facsimile seal appearing was authorized by Robert Nieminen, Florida Registration No.59166,Florida DCA ANE1983 P.E.on 09/20/2017.This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Trinity ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. t TRINITY�ER® ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: GAF Asphalt Roof Shingles,as produced by GAF, have demonstrated compliance with the following sections of the eh Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.4/1507.1.1, Physical Properties ASTM D1970 2015 R905.2.3/R905.1.1 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011 1507.2.7.1,R905.2.6.1 Wind Resistance TAS 107 1995 3. REFERENCES: Entity Examination Reference Date GAF(PDM 1915) Letter of Equivalency Seal-A-Ridge Impact Resistant IR 01/13/2012 PRI(TST 5878) Physical Properties GAF-025-02-01 03/27/2002 PRI(TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004 PRI(TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005 PRI(TST 5878) Physical Properties GAF-324-02-01 12/01/2011 PRI(TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013 UL(TST 1740) ASTM D3462 93NK6295 11/29/1993 UL(TST 1740) ASTM D3462 99NK43835 01/12/2000 UL(TST 1740) TAS 107 94NK9632 03/29/2000 UL(TST 1740) ASTM D3462 OINK06632 02/02/2001 UL(TST 1740) ASTM D3161,TAS 107 DINK9226 05/21/2001 UL(TST 1740) ASTM D3161 OINK37122 12/18/2001 UL(TST 1740) ASTM D3462 01NK37122 12/19/2001 UL(TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002 UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002 UL(TST 1740) ASTM D3161 03CA5367 03/11/2003 UL(TST 1740) ASTM D3462 03NK26444 10/17/2003 UL(TST 1740) ASTM D3462 04NK13850 06/07/2004 UL(TST 1740) ASTM D3161 04NK13850 06/23/2004 UL(TST 1740) ASTM D3161 04NK30546 03/10/2005 UL(TST 1740) ASTM D3462 04NK22009 05/06/2005 UL(TST 1740) ASTM D3161 04NK22009 05/09/2005 UL(TST 1740) ASTM D3462 05NK27924 02/10/2006 UL(TST 1740) ASTM D3161 OSNK27924 02/11/2006 UL(TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006 UL(TST 1740) ASTM D3161,D3462 OGCA18074 06/16/2006 UL(TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006 UL(TST 1740) ASTM D3462 06CA31603 12/01/2006 UL(TST 1740) ASTM D3161,D3462 06CA41095 12/27/2006 UL(TST 1740) A5TM D3161 07NK05228 03/13/2007 UL(TST 1740) ASTM D3161 06CA31611 04/04/2007 UL(TST 1740) ASTM D3161 06CA61148 04/09/2007 UL(TST 1740) ASTM D3161,D3462 07CA31742 11/08/2007 UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 03/13/2008 Exterior Research and Design,U.C. Evaluation Report 01506.01.08-R22 Certificate oJAuthorizallon#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-R20 GAF Asphalt Roof Shingles Revision 22:09/20/2017 Page 2 of 6 NTINITYIERD Entity Examination Reference Date U L(TST 1740) ASTM D3161,D3462 07CA55908 04/01/2008 UL(TST 1740) ASTM D3161,D3462 09CA10592 03/26/2009 UL(TST 1740) ASTM D3161,D3462 09CA06856 05/15/2009 UL(TST 1740) ASTM D3161,D7158,D3462 09NK06647 08/01/2009 UL(TST 1740) ASTM D3161,D7158,D3462 09CA27281 08/27/2009 UL(TST 1740) ASTM D3161,D7158,D3462 IOCA35554 03/05/2010 UL(TST 1740) ASTM D3161,D7158,D3462 10CA13686 05/15/2010 UL(TST 1740) ASTM D3462 IOCA07264 05/27/2010 U L(TST 1740) ASTM D3462 10CA11953 10/29/2010 UL(TST 1740) ASTM D3161,D7158,D3462 1ONK11951 10/30/2010 UL(TST 1740) ASTM D3161,D7158,D3462 1ONK12070 11/04/2010 UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 01/30/2010 UL(TST 1740) ASTM D3161,D7158,D3462 10CA53934 03/31/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48924 10/22/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA47919 12/03/2011 U L(TST 1740) ASTM D3161,D7158,D3462 11CA48408 12/08/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48725 12/09/2011 UL,LLC.(TST 9628) ASTM D3462 12CA34891 10/12/2012 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 12CA58151 02/15/2013 U L,LLC.(TST 9628) ASTM D3161 12CA38083 02/26/2013 U L,I.I.C.(TST 9628) ASTM D3161 13CA32332 06/18/2013 UL,I.I.C.(TST 9628) ASTM D3161 13CA37934 08/02/2013 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4786875675 07/17/2015 UL,I.I.C.(TST 9628) ASTM D3161,D7158,D3462 4787434542 05/17/2016 UL,I.I.C.(QUA 9625) Quality Control Inspection Report,R21,Mobile,AL 10/25/2016 UL,ULC.(QUA 9625) Quality Control Inspection Report,R21,Myerstown,PA 10/20/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tuscaloosa,AL 11/11/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Michigan Cty,IN 11/01/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Shafter,CA 11/17/2016 UL,I.I.C.(QUA 9625) Quality Control Inspection Report,R21,Savannah,GA 11/11/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Minneapolis,MN 10/25/2016 UL,I.I.C.(QUA 9625) Quality Control Inspection Report,R21,Mt.Vernon,IN 10/25/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Baltimore,MD 10/21/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tampa,FL 11/17/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Dallas,TX 11/04/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Ennis,TX 11/03/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Fontana,CA 11/01/2016 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Marquis® WeatherMax®, Royal Sovereign® and Sentinel® are a fiberglass reinforced 3-tab asphalt roof shingles. 4.1.2 Camelot®, Camelot® II, FortitudeTm, Glenwood'"', Grand Canyon®, Grand Sequoia®, Grand Sequoia® IR, Grand Sequoia® ArmorShield"4, Monaco®, Sienna®, Timberline® American Harvest®, Timberline® ArmorShieldlm II,Timberline® Natural Shadow®,Timberline HD®,Timberline®Coo(Series®,Timberline Ultra HD®and Woodland®are fiberglass reinforced,laminated asphalt roof shingles. 4.1.3 Slateline®is a fiberglass reinforced S-tab asphalt roof shingle. 4.2 Hip&Ridge Shingles: 4.2.1 Seal-A-Ridge® Ridge Cap Shingles, Seal-A-Ridge® IR Impact-Resistant Ridge Cap Shingles, Seal-A-Ridge® ArmorShield"l Ridge Cap Shingles and Timbertex®Premium Ridge Cap Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-1122 Certificate of Authorization#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-R20 GAF Asphalt Roof Shingles Revision 22:09/20/2017 Page 3 of 6 QTRINrry I ER® 4.3 Accessory Starter Strips: 4.3.1 Pro-Start®Eave/Rake Starter Strip Shingles and WeatherBlockerm Premium Eave/Rake Starter Strip Shingles are starter strips for asphalt roof shingles. 4.3.2 QuickStart® Peel & Stick Starter Roll is a is a mineral-surfaced, fiberglass-reinforced, self-adhering SBS modified bitumen starter strip,nominal 9-inch x 33 ft roll,for use with asphalt shingles with exposure of 6- inch or less. 4.3.3 StarterMatch m Starter Strip Shingles are color-coordinated starter strips for use with Grand Canyon® and Grand Sequoia® series asphalt shingles. StarterMatch'°' are installed as the second starter for Grand Canyon®and Grand Sequoia®series installations. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable for use in all wind zones up to Vasd=150 mph(V,it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 The GAF hip&ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for use in all wind zones up to Vasd=150 mph(V„it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 614320-3. 6. INSTALLATION: 6.1 Underlavment: 6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3. 6.2 Starter Shingles or Starter Strip: 6.2.1 Installation of Pro-Start Eave/Rake Starter Strip Shingles,WeatherBlocker Premium Eave/Rake Starter Strip Shingles and QuickStart Peel&Stick Starter Roll shall comply with the GAF current published instructions. 6.3 Asphalt Shingles: 6.3.1 Installation of asphalt shingles shall comply with the GAF current published instructions,using minimum four (4)nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions: ➢ Camelot, Camelot II, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Sequoia ArmorShield, and Woodland require minimum five(5)nails per shingle. ➢ Slateline requires minimum six(6)nails per shingle. 6.3.2 Fasteners shall be in accordance with manufacturer's published requirements,but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the GAF for details. Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-1122 Cert4ricate of Authorization#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-1120 GAF Asphalt Roof Shingles Revision 22:09/20/2017 Page 4 of 6 QTRINITYIERD 6.4 Hip&Ridge Shingles: 6.4.1 Installation of Seal-A-Ridge Ridge Cap Shingles, Seal-A-Ridge IR Impact-Resistant Ridge Cap Shingles and Seal-A-Ridge ArmorShield.Ridge Cap Shingles shall comply with the GAF current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and nominal 0.25-inch diameter beads of Henkel"Loctite PL S30 Roof&Flashing Sealant". 11.5° Sealant 1• (292 mm) 1' VE 8sllante (25 mm) (25 mmnduit d'etancheite vrn a _ .f. ._..1i 1Gn'. (305 mm) Nail Clavo 6 5/8•-7 5/8' Clouei (168-194 mm) 12• (305 mm) 6.4.2 Installation of Timbertex Premium Ridge Cap Shingles shall comply with GAF current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and beads of Sonneborn NPI Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant. t -5• Sealant 1' (2E2.rnn3 1' Sotlanta (2a�mrcp (23 rnm? EnOLA d'etasdll is .2' �qucr (345 T.in) 9' (2"MM" 12` 1,305 Hinz) 6.4.3 Fasteners shall be in accordance with GAF published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-R22 Cerdjlcote ojAuthori:ation h9503 6n'EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-R20 GAF Asphalt Roof Shingles Revision 22:09/20/2017 Page 5 of 6 - TRINrry I ERCP 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 614320-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(847)664-3281 END OF EVALUATION REPORT- Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-1122 CertiTicate of Authorization 119503 6°f EDITION(2017)FBC NON-HVHZ EVALUATION FL30124R20 GAF Asphalt Roof Shingles Revision 22:09/20/2017 Page 6 of 6 MIAMI-RADE MIAMI-DARE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)31525-99 NOTICE OF ACCEPTANCE (NOA) www.mianddade.gov/economy Soprema,Inc. 1688 Jean-Berchmans-Michaud Drummondville,Quebec J2C OC2 Canada SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Soprema Lastobond and Resisto Underlayment Products LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 13-0530.02 and consists of pages 1 through 7. The submitted documentation was reviewed by Jorge L.Acebo. NOA No.: 15-0508.04 MIAMI-DADE COUNTY Expiration Date: 09/29/20 •••o o Approval Date: 09/24/15 Page 1 of 7 ROOFING COMPONENT APPROVAL Category Roofing Sub-Category: Underlayment Materials: SBS SCOPE: This acceptance is for Soprema Lastobond and Resisto Underlayment Products as manufactured by Soprema Inc., as described in this Notice of Acceptance,for use with approved prepared roof assemblies as described in this Notice of Acceptance;designed to comply with the Florida Building Code,including the High Velocity Hurricane Zone of the Florida Building Code. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specification Description Lastobond Shield 36"x 75' rolls ASTM D1970 SBS self-adhereing asphalt sheet material for use Manufacturing Location #1 or as an underlayment for Ice Dam Protection in 45"x 75'rolls sloped roof assemblies. "Available as Lastobond Shield 36 and Lastobond Shiled 45 for the 36" wide and 45"wide rolls. Lastobond Pro HT-N 36"x 65' rolls ASTM D1970 SBS self-adhering asphalt sheet material for use as Manufacturing Location #1 an underlayment for Ice Dam Protection in sloped roof assemblies. Resisto SA Smooth Ply 40 40"x 65'rolls ASTM D1970 SBS self-adhering asphalt sheet material for use as Manufacturing Location#1 an underlayment for Ice Dam Protection in sloped roof assemblies. Lastobond Shield HT 36"x 75'rolls ASTM D1970 SBS self-adhering asphalt sheet material for use as Manufacturing Location #1 an underlayment for Ice Dam Protection in sloped roof assemblies. Lastobond Pro HT-S 36"x 65'rolls ASTM D 1970 SBS self-adhering asphalt sheet material for use as Manufacturing Location #1 an underlayment for Ice Dam Protection in sloped roof assemblies. Lastobond 195 36"x 75'rolls ASTM D1970 Self-adhering glass fleece reinforced,SBS Manufacturing Location #1-3 modified bitumen roofing underlayment. Resisto LB1236 36"x 65'rolls ASTM D1970 Self-adhering glass fleece reinforced, SBS Manufacturing Location #1-3 modified bitumen roofing underlayment. Resisto LB1244 44"x 75'rolls ASTM D1970 Self-adhering glass fleece reinforced, SBS Manufacturing Location #1-3 modified bitumen roofing underlayment. NOA No.: 15-0508.04 MIAMI•DADE COUNTY Expiration Date: 09/29/20 12•.0111 Approval Date: 09/24/15 Page 2 of 7 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specification Description Lastobond Eaves Protection 36"x 75'rolls ASTM D1970 Self-adhering glass fleece reinforced, SBS Sheet modified bitumen roofing underlayment. Manufacturing Location #1-3 Lastobond Smooth Seal HT 36"x 65' rolls ASTM D1970 Self-adhering glass fleece reinforced,elastomeric Manufacturing Location #1-3 bitumen roofing underlayment. Lastobond TU HT 39 3/8"x 65 3/5' TAS 103 and Self-adhering glass fleece reinforced,SBS Manufacturing Location #3 rolls ASTM D 1970 modified bitumen roofing underlayment. MANUFACTURING LOCATION: 1. Drummondville,Quebec(Canada) 2. Wadsworth,OH 3. Gulport,MS EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Underwriters Laboratories,Inc. 821824 UL790 09/11/15 Trinity ERD SOPC-SC8970.08.15 ASTM D1970/TAS 110 08/31/15 S31370.03.10-1-R1 ASTM D1970 04/07/10 S37210.11.11 ASTM D1970 11/09/11 S37210.12.11 ASTM D1970 12/01/11 S40540.02.13-1 ASTM D1970 02/19/13 S40540.11.13 ASTM D1970 11/19/13 S43530.02.14-1-R1 TAS 103 05/14/14 S44870.04.14-4 ASTM D1970 04/10/14 S44870.04.14-1 ASTM D1970 04/10/14 S44870.04.14-3 ASTM D1970 04/02/14 S44870.04.14-2 ASTM D1970 04/02/14 S40540.10.14 ASTM D1970 10/31/14 SOPC-SC8520.04.15 TAS 103 04/27/15 NOA No.: 15-0508.04 MIAMI•DADE COUNTY Expiration Date: 09/29/20 Approval Date: 09/24/15 Page 3 of 7 APPROVED ASSEMBLIES: Deck Type 1: Wood,Non-insulated Deck Description: 19/32"or greater plywood or wood plank System E(1): Base sheet mechanically fastened,membrane adhered. Base Sheet: One or more plies of ASTM D226 Type II or ASTM D2626 with a minimum 4"side lap and a 6"end lap mechanically fastened to deck with approved nails and tin caps 6"o.c.at the laps and two staggered rows 12"o.c.the field of the roll. Membrane: One ply of Lastobond Shield,Lastobond Pro HT-N,Resisto SA Smooth Ply 40,Lastobond Shield HT,Lastobond Pro HT-S,Lastobond TU HT,Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Smooth Seal HT,Resisto LB1236 or Resisto LB1244 with mum 3-inch side laps and 6-inch end laps. Starting at the first course,parallel to the eaves align the membrane carefully by completely unrolling and setting it exactly where it will be installed. Once aligned,rewind one half of the length. Gently score the release paper on the high side of this roll,ensuring not to cut through the membrane's thickness. Unroll this first half by evenly peeling back the release paper while simultaneously and slowly pushing out the membrane. Repeat process for remaining one half of the length. Once installed,the membrane must be pressure rolled with a metal or rubber roller. Pressure shall be applied over the entire surface,paying particular attention to all side and end laps. Surfacing: Approved for Mechanically Fastened Metal Roofing,Wood Shake&Shingles,Asphalt Shingles, Slate, Simulated Slate NOA No.:15-0508.04 MIAMMAOE COUNTY Expiration Date: 09/29/20 • Approval Date: 09/24/15 Page 4 of 7 Deck Type 1: Wood,Non-insulated Deck Description: 19/32"or greater plywood or wood plank System E(2): Base sheet mechanically fastened,membrane adhered. Base Sheet: One or more plies of ASTM D226 Type II or ASTM D2626 with a minimum 4"side lap and a 6"end lap mechanically fastened to deck with approved nails and tin caps 6"o.c.at the laps and two staggered rows 12"o.c.the field of the roll.. Membrane: One ply of Lastobond TU HT with minimum 3-inch side laps and 6-inch end laps. Starting at the first course,parallel to the eave,align the membrane carefully by completely unrolling and setting it exactly where it will be installed. Once aligned,rewind one half of the length. Gently score the release paper on the high side of this roll,ensuring not to cut through the membrane's thickness. Unroll this first half by evenly peeling back the release paper while simultaneously and slowly pushing out the membrane. Repeat process for remaining one half of the length. Once installed,the membrane must be pressure rolled with a metal or rubber roller. Pressure shall be applied over the entire surface,paying particular attention to all side and end laps. The Lastobond TU HT shall be back nailed to deck with approved annular ring shank nails and tin caps at a maximum 12"o.c. at the side laps and 6"o.c. at the end laps. No nails or tin caps shall be exposed. Surfacing: Approved for Mechanically Fastened Cement or Clay Roof tiles. Lastobond TU HT may be used with any approved roof tile system adhered as specified in their current NOA using any foam adhesive listed and having a current adhesive NOA approval. NOA No.:15-0508.04 MIAMI•DADE COUNTY Expiration Date: 09/29/20 Approval Date: 09/24/15 Page 5 of 7 LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with the applicable building code. Lastobond Shield,Lastobond Pro HT-N,Resisto SA Smooth Ply 40,Lastobond Shield HT,Lastobond Pro HT-S,Lastobond TU HT,Lastobond 195,Lastobond Eaves Protection Sheet, Lastobond Smooth Seal HT,Resisto LB 1236 or Resisto LB 1244 shall be installed in strict compliance with the applicable building code. 3. Lastobond Shield,Lastobond Pro HT N,Resisto SA Smooth Ply 40,Lastobond Shield HT,Lastobond Pro HT-S, Lastobond TU HT,Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Smooth Seal HT,Resisto LB1236 or Resisto LB1244 shall be applied to a smooth,clean and dry surface,free from irregularities. Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application. When a smooth,clean and/or dry surface cannot be obtained,the substrate shall be primed with Elastocol Stick prior to application.. 4. Lastobond Shield,Lastobond Pro HT-N,Resisto SA Smooth Ply 40,Lastobond Shield HT,Lastobond Pro HT-S, Lastobond TU HT,Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Smooth Seal HT,Resisto LB 1236 or Resisto LB 1244 shall not be applied over an existing roof membrane as a recover system but may be applied over a roofing Base/Anchor sheet underlayment. 5. Lastobond TU HT is acceptable for use in foam adhesive set and mechanically fastened roof tile systems as specified in the surfacing option of the approved assemblies. 6. Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Smooth Seal HT,Resisto LB 1236 or Resisto LB 1244 shall not be left exposed as a temporary roof for longer than 30 days. 7. Lastobond Shield HT,Lastobond Pro HT-S,Lastobond Shield,Lastobond Pro HT-N and Resisto SA Smooth Ply 40 shall not be left exposed as a temporary roof for longer than 90 days of application. 8. Lastobond TU HT shall not be left exposed as a temporary roof for longer than 180 days of application. 9. Lastobond Shield,Lastobond Pro HT-N,Resisto SA Smooth Ply 40,Lastobond Shield HT,Lastobond Pro HT-S, Lastobond TU HT,Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Smooth Seal HT,Resisto LB1236 or Resisto LB1244 may be used with any approved roof covering listing Lastobond Shield,Lastobond Pro HT N,Resisto SA Smooth Ply 40,Lastobond Shield HT,Lastobond Pro HT-S,Lastobond TU HT,Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Smooth Seal HT,Resisto LB1236 or Resisto LB1244 within the Product Approval. If Lastobond Shield,Lastobond Pro HT N,Resisto SA Smooth Ply 40,Lastobond Shield HT,Lastobond Pro HT-S,Lastobond TU HT,Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Smooth Seal HT,Resisto LB 1236 or Resisto LB 1244 is not listed,a request may be made to the Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product Control Department for approval based on the necessary documentation to detail compatibility of the products,wind uplift resistance and fire resistance results. 10. When applying the membrane in the valley,start at the low point and work to the high point,rolling the membrane from the center outward in both directions. For ridge applications,center the membrane and roll from the center outwards in both directions. 11. Membrane shall be applied to protrusions,slope changes,valley,curb,and other roof top penetration details before any other sections of the roof. 12. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.:15-0508.04 MIAMI•DADE COUNTYJI Expiration Date: 09/29/20 • Approval Date: 09/24/15 Page 6 of 7 13. Tiles must be staged onto Lastobond TU HT not to exceed 10-high,to the standard maximum roof pitch of 6:12 for flat tiles and 5:12 for lugged tiles. Lugged tiles staging at slope>5:12 shall use alternate staging method (bottom tile shall be inverted followed by eight tiles high on slope,as illustrated in Figure 1 below). Q. c p : et sj 'i Figure 1: Alternate Staging Method At roof slopes greater than the preceding limitations all tiles shall be loaded onto a nominal 1"x 2"horizontal batten to prevent slippage. 14. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city,state and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MIAMI•DADE COUNTY • END OF THIS ACCEPTANCE NOA No.: 15-0508.04 CMIAMMADECOUNTY Expiration Date: 09/29/20 •• q m Approval Date: 09/24/15 Page 7 of 7