HomeMy WebLinkAboutProduct Approval (2) Certificate of Authorization No. Drive CREEK17520 Edinburgh Drive Tampa,FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE 6'" EDITION (2017) Manufacturer: ALPHA PROTECH ENGINEERED PRODUCTS, INC. lssuedAugust13, 2017 301 South Blanchard Street Valdosta,GA 31601 (229)242-1931 http://www.alphaprotech.com RECEIVED Manufacturing Locations: Valdosta,GA JAN 2 4 2018 Quality Assurance: RADCO, Inc. (QUA1990) ST. Lucie County, Permitting SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1507.1.1 �� Properties: Physical propertiesFILE REFERENC ES Entity Report No. Standard Year PRI Construction Materials Technologies(TST5878) AEP-009-02-01 ASTM D 4533 2015 PRI Construction Materials Technologies(TST5878) AEP-017-02-01 ASTM D 226 2009 ASTM D4869 2016 PRI Construction Materials Technologies(TST5878) AEP-022-02-01 ASTM D 4533 2015 RADCO, Inc (TST1987) RAD-5212 AC 188 2012 RADCO, Inc (TST1987) RAD-4987 ASTM D4533 2015 Rarrtech Laboratories,Inc.(TST6127) 13075-04-08 AC 188 2012 PRODUCT DESCRIPTION REXTM SynFelt Amechanicallyattached,woven polypropylene underlayment(nominal weight=2.56 Ib/100f`2)used an alternative to ASTM D 226,Type Type II roofing underlayments with a minimum tearstrength perASTM D 4533 of 20 pounds, REXtreme A mechanicaIlyattached,woven polypropylene underlayment(nom inal weight=2.97 Ib/100ft2)used an alternative to ASTM D 226,Type II roofing underlayments with a minimum tearstrength perASTM D 4533 of 20 pounds, TECHNOply A mechanicallyattached,woven polypropylene underlayment(nominal weight=2.05 Ib/100ft2)used an alternative to ASTM D 226,Type II roofing underlayments with a m inimum tearstrength perASTM D 4533 of 20 pounds, TECHNO SB A mechanicallyattached,woven polypropylene underlayment(nominal weight=2.00 Ib/100ft2)used an alternative to ASTM D 226,Type II and ASTM D 4869,Type II and IV roofing underlayments with a minimum tearstrength perASTM D 4533 of 20 pounds, APPLICATION INSTRUCTIONS Deck Type: The roof deck shall be constructed of closely fitted, solid sheathing for new or existing construction. Sheathing shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8"gap at abutting joints. Attachment method: Underlayment shall be attached in accordance with the FBC Table 1507.1.1 and manufacturer's installation instructions. APT15001.2 FL12512-R5 Page 1 of 2 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLCof any productchanges orquality assurance changes throughout the duration forwhich this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK ALPHA PROTECH ENGINEERED PRODUCTS, INC. Underlayments TECHNICAL SERVICES, LLC Allowable roof coverings: Permitted to be used as prescribed in FBC Table 1507.1.1 with mechanically fastened roof coverings. LIMITATIONS 1) This evaluation report is not for use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Wind uplift resistance is not within the scope of this evaluation. 4) Installation ofthe evaluated productshall complywith this report,the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources,the more restrictive and FBC compliant installation detail shall prevail. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. Al fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 6) The roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be installed in accordance with FBC requirements. 7) Roof slope limitations shall be in accordance with FBC requirements. 8) Al underlayments shall be installed with the roll length parallel to the eave,starting atthe eave,and lapped in success courses installed up the deck in a manner that effectively sheds water from the deck. End laps shall be staggered between courses in accordance with the manufacturer's application instructions. 9) Contactthe manufacturer when installing attemperatures below the minimum application temperature. 10) The underlayment maybe used as described in other current FBC product approval documents. 11) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically fastened through the underlayment to the roof deck. 12) The underlayment shall be exposed on the roof deck for a maximum 30 days unless otherwise stated. 13) Al products listed in this reportshall be manufactured undera quality assurance program in compliancewith Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code 6th Edition(2017)as evidenced in the referenced documents submitted bythe named manufacturer. %t11111111111111 I.* N•S 20 1 / .08.1 3 No 74021 11 ;40.03 �a -04'00' :1' STATE OF '��'��:•:c< O R p?:•• ��`� Zachary R.Priest,P.E. Florida Rgistration No.74021 1111NA11 1110 O ganization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Sery ices,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a f financial interest in any other entity involved in the approval process of the product. END OF REPORT APT15001.2 FL12512-R5 Page 2 of 2 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEI( Technical Services,LLCof any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation reportdoes not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein.