HomeMy WebLinkAboutRevisions OFFICE USE ONLY: 11 __
DATE FILED: 1 ' Zy1� PERMIT# O
REVISION FEE: �`�', ) RECEIPT#
PLANNING& DEVELOPMENT SERVICES
BUILDING&CODE REGULATION DIVISION RECEIVED
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982-5652
(772) 462-1553 JAN 2 6 2 018
ST, Lucie C4bnty, permitting
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
LOCATION/SITE
ADDRESS:
1721 Mallard Court Ft.Pierce(Parcel Number 3409-503-0020-000/4)
North Fork Estates S/D Lot 17
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
submitting 2 underlayment forms for a shingle roof
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: CCCO56685 ST. LUCIE CO CERT. #:
BUSINESS NAME: Buchanan Services,LLC
QUALIFIERS NAME: Francis Buchanan
ADDRESS: 3300 SW 11th street
CITY: Deerfield Beach STATE: FL ZIP: 33442
PHONE(DAYTIME): 800-379-0122 FAX: 772-324-8090
OWNER/BUILDER INFORMATION:
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE(DAYTIME: FAX:
ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE(DAYTIME): FAX:
SLCCC: 9/23/09
Revised 06/30/17 REVISION
RECEIVED
JAN 2 6 2018
EXTERIOR RESEARCH&DESIGN, LLC.
L
cie County, Permitting Certificate of Authorization##9503
TRINITY ERD 353 CHRISTIAN STREET, UNIT#13
OXFORD,CT 06478
(203)262-9245
EVALUATION REPORT
GAFatiltion Report 01506.03.12-R6
1 Campus Drive y " x FL15487-116
Ar
Parsippany, NJ 07054 '" Date of Issuance:04/23/2012
(800)766-3411 Revision 6:12/15/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: GAF Synthetic Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
OF-
Robert J.M. Nieminen P.E.Nieminen, 'Ofi:�.���Cr r� The facsimile seal appearing was authorized by Robert
Florida Registration No.59166,Florida DCA ANE1983 ;''�S�""" `ti''•`' Nieminen,P.E.on 12/15/2017.This does not serve as an
9 electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. TrinityJERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company
manufacturing or distributing products it evaluates.
2. Trinity)ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing
products for which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval
process of the product.
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
TRINITY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: GAF Synthetic Roof Underlayments, as produced by GAF, have demonstrated compliance
with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the
applicable sections of the following Standards. Compliance is subject to the Installation Requirements and
Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.1.1,T1507.1.1 Unrolling,Breaking Strength, ASTM D226 2009
Pliability
1507.1.1 Tear Strength ASTM D4533 2015
3. REFERENCES:
fRtitY Examination Reference Date
ERD(TST 6049) Physical Properties R3360.02.07-2-R1 03/13/2007
ERD(TST 6049) Physical Properties G12110.12.08 12/02/2008
PRI(TST 5878) Physical properties BRY-003-02-01 03/19/2002
PRI(TST 5878) Physical properties GAF-224-02-01 07/27/2009
PRI(TST 5878) Physical properties GAF-349-02-01 07/03/2012
PRI(TST 5878) FBC 1507.1.1(Exception) GAF-818-02-01 12/05/2017
ITS(TST 1509) Physical properties 100258583COQ-010A 01/11/2011
Miami-Dade(CER 1592) HVHZ compliance 16-1213.04 11/16/2017
Miami-Dade(CER 1592) HVHZ compliance 16-1216.02 02/02/2017
ICC-ES(EVL2396) IBC/IRC compliance ESR-2053 07/01/2017
ICC-ES(EVL2396) IBC/IRC compliance ESR-2808 07/01/2017
ICC-ES(EVL2396) IBC/IRC compliance ESR-3286 02/01/2017
UL,LLC(QUA 9625) Quality Control R10689;Charleston,SC 06/16/2017
UL,LLC(QUA 9625) Quality Control R10689;North Bay,ON 04/05/2017
UL,LLC(QUA 9625) Quality Control R10689;Fontana,CA 07/07/2017
UL,LLC(QUA 9625) Quality Control R10689;McGregor,TX 05/24/2016
UL,LLC(QUA 9625) Quality Control R10689;Pryor,OK 06/20/2017
UL,LLC(QUA 9625) Quality Control R10689;Mission,BC 06/27/2017
4. PRODUCT DESCRIPTION:
4.1 Deck-Armor" Premium Breathable Roof Deck Protection is a non-woven, spun-bonded polypropylene
laminated polyethylene scrim sheet roof underlayment, available in 48-inch or 54-inch roll widths; meets
FBC 1507.1.1(Exception).
4.2 RoofProTM SBS-Modified All-Purpose Underlayment is a fiberglass-reinforced, SBS modified bitumen roof
underlayment;meets AC165.
4.3 Shingle-Mate® Roof Deck Protection is a fiberglass reinforced, asphaltic roof underlayment; meets FBC
1507.1.1(Exception).
4.4 StormSafe'" Anchor Sheet is a polypropylene woven fabric which serves as an anchor sheet in two-ply
roof underlayment systems; meets FBC 1507.1.1(Exception).
4.5 Tiger Paw" Roof Deck Protection is a non-woven, polypropylene reinforced, polymer coated roof
underlayment; meets FBC 1507.1.1(Exception).
Exterior Research and Design,I.I.C. Evaluation Report 01506.03.12-116
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL15487-116
GAF Synthetic Roof Underlayments Revision 6:12/15/2017
Page 2 of 6
TRINITY ERD
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory or test report from accredited testing agency for fire ratings of this product.
5.4 GAF Synthetic Roof Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request may be made to the
Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the
prepared roof covering.
5.5 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Wood Slate or
Shingles Tile
Underlayment Asphalt Nail-On Tile Foam-On a Metal Shakes& Simulated
Shingles Slate
Deck-Armor"Premium
Breathable Roof Deck Yes No No Contact Mfg Contact Mfg Contact Mfg
Protection
RoofPro"SBS-Modified
All-Purpose Yes No No No Yes Yes
Underlayment
Shingle-Mate®Roof
Yes No No No No No
Deck Protection
Tiger Paw`"Roof Deck Yes No No Contact Contact Contact
Protection Mfg. Mfg. Mfg.
5.6 Exposure Limitations:
Deck-Armor'" Premium Breathable Roof Deck Protection; RoofPro'" SBS-Modified All-Purpose
Underlayment; Shingle-Mate® Roof Deck Protection; StormSafe'" Anchor Sheet; Tiger Paw'" Roof Deck
Protection shall not be left exposed for longer than 30-days after installation.
6. INSTALLATION:
6.1 GAF Synthetic Roof Underlayments shall be installed in accordance with GAF published installation
instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application.
6.3 Deck-Armor'" Premium Breathable Roof Deck Protection:
6.3.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC
Table 1507.1.1 for the type of prepared roof covering to be installed, taking into account the wider Sheet-
width for double-layer applications.
6.3.2 Fasteners shall be 1-inch diameter plastic-capped corrosion resistant nails or 1-inch diameter plastic-
capped,corrosion resistant staples.
Exterior Research and Design,LLC. Evaluation Report 01506.03.12-116
Certificate of Authorization 119503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL1S487-R6
GAF Synthetic Roof Underlayments Revision 6:12/15/2017
Page 3 of 6
TRINITY ERD
6.3.3 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of Liberty— SBS Self-
Adhering Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier; UnderRoof'°" 2 Polyester-Surfaced Leak
Barrier; UnderRoof'" HT High Temperature Leak Barrier; WeatherWatch® Mineral Surfaced Leak Barrier or
WeatherWatch® XT Mat Surfaced Leak Barrier at vulnerable leak areas, including but not limited to eaves,
valleys, rakes, skylights and dormers. At eaves and valleys, install the leak barrier prior to installation of
the underlayment. Along the rake, install the underlayment, leaving 6 to 8-inch of the deck exposed, and
then install the leak barrier over the underlayment and exposed decking. At other areas, install the leak
barrier over the underlayment. Refer to FL10626.
6.3.4 Non-Tile Roof Installations:
Single Laver; Roof Slope>4:12:
Starting at the eave,fasten the eave edge and 6-inch wide end-laps 6-inch o.c. Fasten in the field of the roll
12-inch o.c.in two,equally spaced,staggered center rows.
Continue upslope in a similar manner, maintaining minimum 3-inch side-laps and minimum 6-inch end-
laps. Fasten 6-inch o.c. in the laps and 12-inch o.c. in two, equally spaced, staggered center rows in the
field. Ensure all end laps are staggered at least 3-feet apart.
Double Laver;2:12< Roof Slope<4:12:
If leak barrier (6.3.3) is not used, install a half-width sheet at the eave prior to subsequent courses.
Starting at the eave,fasten the eave edge and 6-inch wide end-laps 6-inch o.c. Fasten in the field of the roll
12-inch o.c.in two,equally spaced,staggered center rows.
Continue upslope in a similar manner,with minimum 25.5-inch side-laps for 48-inch wide rolls(resulting in
maximum 22.5-inch exposure) or minimum 28.5-inch side-laps for 54-inch wide rolls (resulting in
maximum 25.5-inch exposure) and minimum 6-inch end-laps. Fasten 6-inch o.c. along the low edge and
end laps and 12-inch o.c. in two,equally spaced,staggered center rows in the field. Ensure all end laps are
staggered at least 3-feet apart.
6.4 Tiger PawTM Roof Deck Protection:
6.4.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC
Table 1507.1.1 for the type of prepared roof covering to be installed, taking into account the wider sheet-
width for double-layer applications.
6.4.2 Fasteners shall be 1-inch diameter plastic-capped corrosion resistant nails or 1-inch diameter plastic-
capped,corrosion resistant staples.
6.4.3 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of Liberty'" SBS Self-
Adhering Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier; UnderRoof7" 2 Polyester-Surfaced Leak
Barrier; UnderRoof'" HT High Temperature Leak Barrier; WeatherWatch® Mineral Surfaced Leak Barrier or
WeatherWatch®XT Mat Surfaced Leak Barrier at vulnerable leak areas, including but not limited to eaves,
valleys, rakes, skylights and dormers. At eaves and valleys, install the leak barrier prior to installation of
the underlayment. Along the rake, install the underlayment, leaving 6 to 8-inch of the deck exposed, and
then install the leak barrier over the underlayment and exposed decking. At other areas, install the leak
barrier over the underlayment. Refer to FL10626.
6.4.4 Non-Tile Roof Installations:
Single Laver; Roof Slope>4:12:
Starting at the eave,fasten the eave edge and 6-inch wide end-laps 6-inch o.c. Fasten in the field of the roll
12-inch o.c.in two,equally spaced,staggered center rows.
Continue upslope in a similar manner, maintaining minimum 3-inch side-laps and minimum 6-inch end-
laps. Fasten 6-inch o.c. in the laps and 12-inch o.c. in two, equally spaced, staggered center rows in the
field. Ensure all end laps are staggered at least 3-feet apart.
Exterior Research and Design,U.C. Evaluation Report 01506.03.12-116
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL1S487-116
GAF Synthetic Roof Underlayments Revision 6:12/15/2017
Page 4 of 6
TRINITY ERD
Double Laver; 2:12<Roof Slope<4:12:
If leak barrier (6.4.3) is not used, install a half-width sheet at the eave prior to subsequent courses.
Starting at the eave,fasten the eave edge and 6-inch wide end-laps 6-inch o.c. Fasten in the field of the roll
12-inch o.c.in two,equally spaced,staggered center rows.
Continue upslope in a similar manner, with minimum 25.5-inch side-laps (resulting in maximum 22.5-inch
exposure) and minimum 6-inch end-laps. Fasten 6-inch o.c. along the low edge and end laps and 12-inch
o.c. in two, equally spaced,staggered center rows in the field. Ensure all end laps are staggered at least 3-
feet apart.
6.5 StormSafe'"A Anchor Sheet:
6.5.1 StormSafe'" Anchor Sheet is limited to use as a mechanically attached base layer in 2-ply underlayment
systems.
6.5.2 Fasteners shall be 1-inch diameter plastic- or steel-capped corrosion resistant nails; corrosion-resistant
nails&1-5/8-inch tin-caps;or Drill-Tec screws and plates.
6.5.3 Non-Tile Roof Installations:
Starting at the eave,fasten the eave edge and 6-inch wide end-laps 6-inch o.c. Fasten in the field of the roll
12-inch o.c.in two,equally spaced,staggered center rows.
Continue upslope in a similar manner, maintaining minimum 3-inch side-laps and minimum 6-inch end-
laps. Fasten 6-inch o.c. in the laps and 12-inch o.c. in two, equally spaced, staggered center rows in the
field. Ensure all end laps are staggered at least 3-feet apart.
One the same day, install Liberty'" SBS Self-Adhering Base/Ply; StormGuard® Film Surfaced Leak Barrier;
UnderRoof'" HT High Temperature Leak Barrier; WeatherWatch® Mineral Surfaced Leak Barrier or
WeatherWatch®XT Mat Surfaced Leak Barrier over the StormSafe'"Anchor Sheet. Refer to FL10626.
6.6 RoofPro'""SBS-Modified All-Purpose Underlayment and Shingle-Mateo Roof Deck Protection:
6.6.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC
Table 1507.1.1 for the type of prepared roof covering to be installed. No hammer tacks or staples are
permitted.
6.6.2 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of Liberty— SBS Self-
Adhering Base/Ply Sheet;StormGuard® Film Surfaced Leak Barrier; UnderRoof m HT High Temperature Leak
Barrier;WeatherWatch® Mineral Surfaced Leak Barrier or WeatherWatch®XT Mat Surfaced Leak Barrier at
vulnerable leak areas, including but not limited to eaves, valleys, rakes, skylights and dormers. At eaves
and valleys, install the leak barrier prior to installation of the underlayment. Along the rake, install the
underlayment, leaving 6 to 8-inch of the deck exposed, and then install the leak barrier over the
underlayment and exposed decking. At other areas, install the leak barrier over the underlayment. Refer
toFL10626.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
Exterior Research and Design,I.I.C. Evaluation Report 01506.03.12-116
Certificate of Authorization#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL15487-R6
GAF Synthetic Roof Underlayments Revision 6:12/15/2017
Page 5 of 6
TRINITY ERS
H. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements.
The following plants have qualified products under their respective physical properties specifications.
Plant Specification Product s
North Bay,Ontario FBC 1507.1.1(Exception) Deck-Armor'"Premium Breathable Roof Deck Protection,StormSafe'"
Anchor Sheet
Fontana,CA AC165 RoofProT"SBS-Modified ATI-Purpose Underlayment
Pryor,OK FBC 1507.1.1(Exception) Shingle-Mate®Roof Deck Protection
McGregor,TX FBC 1507.1.1(Exception) Shingle-Mate®Roof Deck Protection
Mission,BC FBC 1507.1.1(Exception) Tiger Paw—Roof Deck Protection
Charleston,SC FBC 1507.1.1(Exception) Tiger Paw'"Roof Deck Protection
9. QUALITY ASSURANCE ENTITY:
UL, LLC.—QUA9625;(847)664-3281
-END OF EVALUATION REPORT-
Exterior Research and Design,I.I.C. Evaluation Report 01506.03.12-116
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVH2 EVALUATION MS487-116
GAF Synthetic Roof Underlayments Revision 6:12/15/2017
Page 6 of 6