HomeMy WebLinkAboutBuilding Permit Application ALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: ' Permit Number: I
RECEIVED
Building Permit Application JAN 2 4 2018
Planning and Development Services
Building and Code Regulation Division ST. Lucie County, Permitting
2300 Virginia Avenue,Fort Pierce FL 34982
Phone: (772)462-1553 Fax: (772)462-1578 Commercial Residential x
PERMIT APPLICATION FOR: Roof
PROPOSED IMPROVEMENT LOCATION:
Address: 5775 Clydesdale Lane
Legal Description: Pony Pines-unit one Blk A Lot 7
Property Tax ID#: 3309-605-0010-000-7 Lot No.7
Site Plan Name: Pony Pines Block No. A
Project Name: Joe Dacosta
Setbacks Front Back: Right Side: Left Side:
DETAILED DESCRIPTION OF WORK:
Remove & replace asphalt shingle roof. 6AAS6 dLe W S 46 O kov, 4*4
Pahl vrtr xe idwMme;d.:Ao�*--1to-Pak; +ne oas LA (o"o.
CONSTRUCTION.INFORMATION.: ,
Additional work toe nerformed under this permit—check all appy:
HVAC Gas Tank as Piping _Shutters Windows/Doors
Electric ❑ Plumbing Sprinklers Generator Roof 612 Roof pitch
Total Sq. Ft of Construction: 2,000 sglft SFt.of FirstMseptic
Cost of construction:$ $9800.00 Utilities:iSewer Building Height: 12'
OWNER/LESSf : ° CONTRACTO.F
Name Joe Dacosta Name: DavidAOuken
Address: 5775 Clydesdale Lane Company: CARIBBEAN CONSTRUCTION SERVICE,LLC
City: Fort Pierce State:FL Address: 4859 NE 12th Ave
Zip Code: 34987 Fax: City: Oakland Park State:FL
Phone No.772-215-6020 Zip Code: 33334 Fax: 954-900-3135
E-Mail: Phone No. 954-249-7196
Fill in fee simple Title Holder on next page(if different E-Mail:lose@caribbeanconstructionservice.com
from the Owner listed above) State or County License: CCC-1326961
If value of construction is$2500 or more,a RECORDED Notice of Commencement is required.
SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION:
DESIGNER/ENGINEER: _Not Applicable MORTGAGE COMPANY: _Not Applicable
Name:--- Name:D—A
Address:5775 Ctydesdak;Lane Address: 5775 Clydesdale Lane
City: State: City: Oakland Park State:
Zip: Phone Zip: Phone:
FEE SIMPLE TITLE HOLDER: _Not Applicable BONDING COMPANY: Not Applicable
Name: Name:
Address:4859 NF 12th Ave Address:
City: City:
Zip: Phone: Zip: Phone:
OWNER/CONTRACTOR AFFIDVIT: Application�s hereby made to obtain a permit to do the work and installation as indicated.
I certify that no work or installation has commenced prior to the issuance of a permit.
St.Lucie County makes no representation that is granting a permit will authorize thepermit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules,bylaws or and covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested perrnit,I do hereby agree that I will,in all respects,perform the work
in accordance with the approved plans,the Florida Building Codes and St.Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review:room additions,
accessory structures,swimming pools,fences,walls,signs,screen rooms and accessory uses to another non-residential use
WARNING TO OWNER:Your failure to Record a Notice of Commencement may result in your paying twice for
improvements to your property.AN ice of Commencement must be recorded and posted on the jobsite
before the first inspection. If you inte d to obtain financing, consult with lender or an attorney before
commencin work or record in our otice of Commencement.
ig ture of Owner/Lessee/Contractoras Agent for Owner Signature}of Contractor/License Holder _
STATE OF FLORIDA (�trta� STATE OF FLORIDA a
COUNTY OF COUNTY OF U
The forg,yQn�g instrume t was acknowledged before me The fo %jng instrument was acknowledged.before me o
this r`tlay of 201f by this 1 day of �w 20 by
* b
S o. 0-VI �N►� � c
�SO(. Qac.o� � �0
Name of person making statement / Name of persorymaking statement Vit,•
Personally Known OR Produced Identification VI Personally Known � OR Produced Identification `oti
Type of Identifif a4ion f Type of Identification
Produced (i+(.L-Vfd�Q�I�K� Produced
" •.°j�� RALPH PAU A
o��er vie RALPH PA LA r x MY Cokw.lsslciv
e 5
(Signature f Not Public State of Flip * � ture of Notary Public-State of FI '�� gordedThr�Bu^et N^ nkat
EXPIRES:Octo T 2019 Q
Commission No. J a'' �r BordedThrj9AetN WARMission No. FF �v K�(J" (Seal)
REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE
COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW
DATE
RECEIVED
DATE
COMPLETED
Rev.8/2/17
JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT - SAINT LUCIE COUNTY
FILE # 4393653 OR BOOK 4089 PAGE 2373, Recorded 01/24/2018 08 :07 : 19 AM
RECEIVED
JAN 2 4 2018
NOTICE OF COMMENCEMENT ST. Lucie County, Permitting
Permit No. Property Taz ID No. 3309-605-0010-000-7
State of Florida,County of St.Lucie
The Undersigned hereby gives notice that improvement will be nude to certain real property,and in accordance with
Chapter 713,Florida Statutes,the following information is provided in this Notice of Commencement.
Legal Description of property and address if available Pony Pines-Unit One Blk A Lot 7
w
General description of improvements Removo 6 replace asphalt shingle roof.
Owner/let;see Joe Dacosta
Address 5775 Clydesdale Lane w
z
Interest in property: Owner to LL im
to O Uj
Fee Simple Title holder(if other than owner) rile
Address 5775 Clydesdale Lane;Fort Pierce, FL 34,987 O =
Y
Contractor Caribbean Construction Service,LLC Phone# 954-249-7196 U H
U
4859 NE T 2th Ave 954-900-3135 ¢ LL W '
Address_ Fax# 0_—oc iy
5
sx a
Surety rVa _ Phone#n/a [�]n W O a o
rj
U W
Address rVa Fax# rVa "U O 0: O
Amount of Bond Na p U H d Z—
LU
W'U_'
Lender n/a Phone# rve Q _ 0
O
Address n/a Fax# Iva
Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided
by Section 713.13(a)7.,Florida Statues:
Name n/a Phone#
Address rVa Fax# _
In addition to himself,owner designates ✓a T_ _ of
Phone# Fax#
to receive a copy of the Lknor's Notice as provided In Section 713.13(1)(b),Florida Statutes. Expiration date of notice of
commencement is one year from the date of recording unless a different date is specified. WARNING TO OWNER:
ANY PAYME.NTS MADE BY THE OWNER AF-I'ER I-HE EXPIRATION OF IIM NOTICL OF COMMENCFMEr NT ARL CONSPIRED I[MFROPiR
PAYMF.NI-S UNDER CH.713.13,F.S.,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED A.ND POSTED ON TUEJOB SITE BEFORE TTIE FIRST 'I PECTION.IF YOU MLTND TO OLITAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN AT'IORNF;Y HFFORF: COMMENCING ORK OR RECORDING YOUR NOTICE OF
COMMENCMENT.
C—
/I.eswr,or Owner's or Lessee's Authorized Ol7ker'Dir«torfrartuerrMaaagtr/Signature
oe Dacosta/Owner
Siau■�orY'f 7h)dOttke
State of Florida,County of Saint Lucie _ 1 .�
Acknowledged before me this 1 day of -W" 20 ,by �0� C6Sta
who is personallyjcnown to me or who has produced ks L4rA*1J as identification
Signatur of Notary 'I'ype or Print Name of Notary (.Seal)
Q [el
Title:Notary Public Commission Number_ � o J "o^•11MF PIA PM PAULA
* t MY COA&!SSION#FF 924
EXPIRES825
:October 6,2019
e+,raM1yr� BsredTiw Bldget FbYry Straus
CIO-
't' t CIE
f..
=RECEIVED
Planning & Development Services
Building & Code Regulation Division
COUNTY -Ah. 2300 Virginia Ave
Fort Pierce, FL 34982
772462-1553 Fax 772462-1578
ASBESTOS NOTICE TO CONTRACTOR
Date: 1/18/2018
Contractor Name: David A Quillen
Business Name: Caribbean Construction Service, LLC
Address: 4859 NE 12th Ave
City: Oakland Park State: FL
Zip Code: 33334
Re: Job Address: 5775 Clydesdale Lane
It is your responsibility to comply with the provisions of Section 469.003, Florida Statutes
and to notify the Department of Environmental Protection of any intentions to remove
asbestos when applicable in accordance with state and federal law.
Signature & Date
Florida Building Code 6th Edition (2017)
High-Velocity Hurricane Zone Uniform Permit Application Form_
RECEIVE[` _ )
INSTRUCTION PAGE JAN 2 4 2013
ST. Lucie County, Perm�tt,c,
COMPLETE THE NECESSARY SECTIONS OF
THE UNIFORM ROOFING PERMIT
APPLICATION FORM AND ATTACH THE
REQUIRED DOCUMENTS AS NOTED BELOW:
Roof System Required Sections of the Attachments Required
Permit Application Foran See List Below
Low Slope Application A,B,C 1,2,3,4,5,6,7
Prescriptive BUR-RAS 150 A,B,C 40,6,7
Asphaltic Shingles A,B,D 1,2,4,5,6,7
Concrete or Clay Tile A,B,D,E 1.2.3.4.5,6,7
Metal Roofs A,B,D 1,2,3,4,5,6,7
Wood Shingles and A,B,D 1,2,4,5,6,7
Shakes
Other As Applicable 1,2,3,4,5,6,7
ATTACHMENTS REQUIRED:
1. Fire Directory Listing Page
2. From Notice of Acceptance:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3. Design Calculations per Chapter 16, or If Applicable, RAS 127 or
RAS 128
4. Other Component Notice of Acceptances
5. Municipal Permit Application
6. Owners Notification for Roofing Considerations (Re-Roofing On
7. 1 Any Required Roof Testing/Calculation Documentation
•
l
w * A4 f'.;"€x- . ,. , 5'-
•
_ fwy....i+Y.:•-.M•YM......-., ; _aer..•_.a-n.►w-w. a u-..fir-. .......�. «vw_s...y.w a.. r..[ - '
t ... v ,.,., ..-....t «._. y •..- ♦ e ..Nw •Y�w•IbwaJ••w...:upe,: v,r.. „
,; � .::_:: _..•... ... _.. �` ,. ;,.s•. .r � a, -� "tom s t�3 ,,
_. ._ "" .A•'•S« °r (" +.TMJ' e4 Y �i4((j
.� ... -,aft
}}
• CJ x
_
: � ,�� �-� +,oe:' �L'f�° t# •' :az: a �!' 3' i xa t ' 34 �?' •' �'•,�t;�;° +x+j �' - _: ,
A Ay, :,-'"-. ! <d`. #�'i �.,♦ ':1i : .. ''.�?. . •tia„?�.t tai '9 ..r .k -- K{ - t -.
off, 110
i
AT)MAT i
1
Qj r
:� �!i�” "_� x ��-'r:,SF'._ # >w' : w '� '.i"€' :r1�� S :. • 'aas"3{�. r 3.tD,'� }!"`• tt'�� �.`-3
'ij''• •�•i ."s.. .,.. :,. i9M g4 Ys Mie i ";v ,r a 1 AT; -s ; i�.1 7' $'c> E'1<7 w f �$ •'}. 9 {-
S 7
oil
VIA
• _
-}
2 i t r nor;
i ' .> ..
A
1 R` - - { • w
tfix
} _
- .:... ..�.., ... . .,.. .: .«►.., •.-µ.� ..-+�cnF„lew� ».-.aL .mac-�.t.&is rw
��i�8�•�`•k.`Sr �• .,r,i-: a.. �s•�r� -yT.�"�.•sAr'�ie §ffii;`::t?,a'.•.u-inrS.rr.�2d.. ,.,Es�,�'ff ;:�:.t .K,.� �c,w^,sarr�r:r:;w' .r s'.-.de8.,�. ��,.- ti>,a$:�,rr�, �,. ., . ..'-sie,,, .. �r.,
Joe • . Legend
5775 Clydesdale
i
�w
5 775 Clydesdale Ln sem.
y
a
n
M
"WNW,
ie
k
TOW
gooslc"-Orta N
Google 4e I 70 ft
Florida Building Code 6th Edition (2017)
High-Velocity Hurricane Zone Uniform Permit Application Form
Section C (Low Sloped Roof System)
Fill in Specific Roof Assembly Components Fastener Spacing for Anchor/Base S eet
and Identify Manufacturer Attachment
(If a component is not used,identity as'NA*)
Field: oc @ Lap,#Rows_ 'oc
System Manufacturer.
Perimeter: oc @ Lap,#Rows @_'oc
NOA No.:
Comer. oc @ Lap,#R _@ oc
Design Wind Pressures,From RAS 128 or Calculations:
Number of Fastens Per Insulation
Pmax1: Pmax2: Pmax3: Board
Max.Design Pressure,From the Specific NOA
System: Field P rimeter Corner
Deck: Illustrate omponents Noted and
Type: Details s Applicable:
Gauge/Thickness: Woodbl ing, Gutter, Edge Termination,
Strip ' g, FI sh g, Continuous Cleat, Cant
Slope: St ' Bas F shing, Counter- Flashing,
ping, Et .
Anchor/Base Sheet&No.of Ply(s): oof Height, Parapet Height,
Height of ase lashing, Component Material,
AnchorBase Sheet Fastener/Bonding Material: Material hickne s, Fastener Type, Fastener
Spacin or Submit Manufacturers Details that
Insulation Base Layer. Compl with RAS 111 and Chapter 16.
Base Insulation Size and Thickness:
Base Insulation Fastener/Bonding rial:
Top Insulation Layer. FT,
Top Insulation Size andZTh' ness: Parapet
Top Insulation Fastenaterial: Heiqht
Base Sheet(s)& o.of Ply(s):
FT.
Base Sheet F tener/Bonding Material:
- Mean
Roof
Ply Sheet(s)&No.of Ply(s): Height
Ply Sheet Fastener/Bonding Material:
Top Pty.
Top Ply Fastener/Bonding Material:
Surfacing:
Florida Building Code 6th Edition (2017)
High-Velocity Hurricane Zone Uniform Permit Application Form
Section D (Steep Sloped Roof System)
Roof System Manufacturer: 6*4 /
Notice of Acceptance Number: /f _dU 11 • I
Minimum Design Wind Pressures, if Applicable (From RAS 127 or Calculations):
P1: P2: P3: N
Maximum Design Pressure A,
From the NOA Specific System):
1 "
Method of Oftr attachment:
Steep Sloped Roof System Description
Deck Type:
ype Unde ay ent: V
Roof Slope:
nsulation:
: 12
FireBar er:
/—/, P-
Ridge Ventilation? astener Type &Spacing:
dhesive Type -1
ype Cap Sheet:
oof Covering:
Mean Roof Height:
Type&Size brip
Edge: ,
"1:4
t
It
tj
k
} . , .. ».-. x -,.�.. .1 o�a„ k . .'s s �"Y;.� ter ,;y;•yipa��
r
•
r- 1 • y-i _e."i �� t�' ,ti ,`fig a ..µ � +o:/,:'Y:�1% tt
_
t
S
a
i
. n
4 a
• y� g � " k It i �} ... 1�G t, .- ,.,rg i`,.�� ,'� k� '. r„ • �aY .q -�! :
y
t .
t�
_
Florida Building Code 6th Edition (2017)
+ High-Velocity Hurricane Zone Uniform Permit Application Form
Section E (Tile Calculations)
For Moment based tale systems,choose either Method 1 or 2.Compared the values
for M,with the values from Mt.If the Mr values are greater than or equal to the Mr
values,for each area of the roof,then the We attachment method is acceptable.
Method 1 "Moment Based Tile Calculations Per RAS 127"
(Pt: :X _ —Mg: _Kt NOA
(P3: t;L _ a—Mg: =M, A ?%
Method 2"Simplified'Iii Calc ala ' a Per T Below"
Required Moment of Resistance(M,)From Ta a Below OA N*
M. Requl Res nce
Man
a lent —
Roof slope 15' 2S 30' 40'
2:12 34A42.2
32.2 34A 36.0 3 .
2 30A 2 8 35.1 37.3
5:12 28A 30.1 31.6 34.9
26.4/ 28.0 29A 30.5 32A
:12 25.9 282 .0
*Must be used in conjunction a list of moment based tile systems endorsed by the
Broward/roofen
d of R and Appeals.
For Upe tems use Method 3. Compared the values for F' with the
values f ' values are greater than or equal to the F,values,for each
area of n the tle attachment method is acceptable.
od 3"Uplift Based Tile Calculations Per RAS 127'(PI:_ i w:_ }—W: z cos 8: = F,t: NOA F'
(P2:_ i W:=_J-W: a cos 0:_= F,2: NOA F'
(P3:_z1: =_Z w: W:_:Cos 0:_= F,3: NOA F'
Where to Obtain Information
Description Symbol Where to find
Design Pressure P I or P2 or P3 RAS 127 Table 1 or by an engineering analysis prepared by PE based on ASCE
7
Mean Roof Height H Job Site
Roof Slope g Job Site
Aerodynamic Mul' lier I NOA
Reapring Moment due to Gravity MA NOA
Attacbmaat Resisbuwc M, NOA
Required Manual Reeipanoe M, Calculated
Minimum Anacbmeat$ aisume F NOA
Required Uplift Resistance F, CaWated
! v Tile W ' NOA
Tule Dimension 1=iongt NOA
W=Widlh
All calculations must be submitted to the Buikling Official at the time ofpernmt gplication.
Wayne Comer ��N
From: Abbona, Claudia [cabbona@gaf.coml
Sent: Wednesday, February- 27, 2008 8:29 AM =RECETVEDTo: Wayne Comer
Subject: Emailing: showpage
Wayne;
Sorry you did not received the fax, my machine never sent me an error report.
Ijy�I.Ql�I.IME CERTIFICATIONS D(� TORY
�..� TFWZ"R21
Prepared Roof Covering Materials
Page Bottom
Prepared Roof Covering Materials
Sec.-General Information for Preaared Roof.Co_vering Materials
GAF MATERIALS CORP R21
1361 ALPS RD
WAYNE, N)07470 USA
Asphalt organic/glass fiber mat shingles and sheet roofing,for installation as Class C prepared roof coverings.
Asphalt organic/glass fiber mat shinglesfor installation as wind resistant roof coverings.
Asphalt glass fiber mat shingles, for installation as Class A roof covering. Suitable for installation on minimum 3/8 in, thick
plywood.
"Slateline" asphalt glass fiber mat shingles , for installation as Class A roof covering. Suitable for installation on 15/32-in. thick
plywood in combination with minimum one ply"Shingle-Mate"or Type 15 or Type 30 underlayment
Asphalt glass fiber mat shingles,for installation as wind resistant roof coverings.
Asphalt glass fiber mat sheet roofing,for installation as Class C prepared roof covering.
Asphalt glass mat shingles,for installation as wind resistant roof coverings.
Asphalt glass mat shingles, for installation as Class A prepared roof covering when used with minimum Type 30 underlayment
over existing wood shingle roof.
Modified asphalt glass fiber mat shingles,for installation as Class A prepared roof coverings.
Asphalt glass mat shingles, Classified in accordance with"ASTM D3462", CAN/CSA A123.5-M90.
For installation as wind-resistant roof coverings. May also bear the following statement"Also evaluated at velocities up to 110 mph".
2/27/2008
Miami-Dade County Building
Product Information for N.O.A. 16-0811.11
NOA 16-0811.11 (Iibrarw6productcontrollnoa/16081111.ndf)
Superseded By
File Status File Approved
File Classification High velocity hurricane zone
Category Roofing
Subcategory Asphalt Shingles
Material Laminate
Applicant GAF(Pc-result detail app.asp?app alias=100195)
Expiration—Date February/21/2022
Impact Rate Unselected/Unknown
Maximum Desigr_Pressure Positive 0
Maximum—Design—Pressure Negative 0
Description GAF Timberline HD, Timberline Natural Shadow, Timberline American Harvest, and Fortitude
Shingles
Green—Sustainable—Attributes NONE
For a detailed description on the File Status, click the NOA File Status Key. (/buildinq/pc-result keV app.asp)
Page Last Edited:Wed Jan 25. 2017 10:40:27 AM
MIAMFWDE
LRECEIVED
2 4 2018 MIAMI-DADE COUNTY
HIAN Count , Perm
DUCT CONTROL SECTION
Y 9 11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) NN%N�.tniamidade.2ov/econoniv
GAF
1 Campus Drive
Parsippany,NJ 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION GAF TimberllineHD®, imberline®Natural Shadow®,Timberline®American Harvest®,and
FortitudeTM hingles
LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA# 14-1022.20 and consists of pages I through 6.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 16-0811.11
t t �Qj0'�oou
Expimflon Date:02/21/22
Approval Date:02/09/17
Page 1 of 6
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Asphalt Shingles
Materials: Laminate
Deck Type: Wood
SCOPE
This approves GAF Timberline HD®,Timberline®Natural Shadow®,Timberline American®Harvest®,and
Fortitude m Shingles as manufactured by GAF as described in this Notice of Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test Product Description
Specifications
GAF Timberline tID® 13 '/4"x 39'/8" TAS 110 Fiberglass reinforced heavy weight asphalt
Manufacturing roof shingle,with a laminate profile
Locations#1,2,3,4,5,6,7
GAF Timberline Natural 13 '/a"x 39'/8" TAS 110 Fiberglass reinforced heavy weight asphalt
Shadow® roof shingle,with a laminate profile
Manufacturing
Locations#1,2,3,4,5,6,7
GAF Timberline®American 13 '/4"x 39'/8 TAS 110 Fiberglass reinforced heavy weight asphalt
Harvest® roof shingle,with a laminate profile
Manufacturing
Locations#2,4,5,6
GAF Fortitude7"' 13 '/aT x 39'/8 TAS 110 Fiberglass reinforced heavy weight asphalt
Manufacturing roof shingle,with a laminate profile
Locations#1,4
MANUFACTURING LOCATION
1. Tampa,FL
2. Michigan City,IN
3. Baltimore,MD
4. Myerstown,PA
5. Ennis,TX
6. Tuscaloosa,AL
7. Dallas,TX
NOA No.: 16-0811.11
Muu�EaanE counmr Expiration Date:02/21/22
�® Approval Date:02/09/17
Page 2 of 6
EVIDENCE SUBMMED
Test Aeencv Test Identifier Test Name/Report Date
Underwriters Labomtones,LLC ASTM D3462 4787344101 07/25/16
Underwriters Laboratories,Inc. ASTM D3462 l 1 CA48924 10/24/11
Underwriters Laboratories,Inc ASTM D3462 IOCA21994 04/22/11
Underwriters Laboratories,Inc ASTM D3462 IOCA28717 07/26/11
Underwriters Laboratories,Inc. ASTM D3462 05CA47541 11/10/06
Underwriters Laboratories,Inc. ASTM D3462 06CA31580 11/30/06
PRI Asphalt Technologies,Inc. ASTM D3462 GAF-101-02-02 11/02/05
Underwriters Laboratories,Inc. ASTM D3462 06NK05159 08/09/06
PRI Asphalt Technologies,Inc. ASTM D3462 GAF-098-02-02 11/08/05
Underwriters Laboratories,Inc. ASTM D3462 02NK41809 08/11/02
Underwriters Laboratories,Inc. ASTM D3462 03NK26444 10/17/03
Center for Applied Engineering ASTM D3462 257989 05/13/97
Underwriters Laboratories,Inc. TAS 107 OINK45803 04/13/94
Underwriters Laboratories,Inc. TAS 107 06NK05159 08/09/06
Underwriters Laboratories,Inc. TAS 107 04NK04273 02/20/04
Underwriters Laboratories,Inc. TAS 107 05CA42840 11/11/05
Underwriters Laboratories,Inc. TAS 107 02NK41811 11/11/02
Underwriters Laboratories,Inc. TAS 107 03CA35209 10/17/03
Underwriters Laboratories,Inc. TAS 107 04CA13850 08/30/04
Center for Applied Engineering TAS 100 257989 04/01/97
PRI Asphalt Technologies,Inc. TAS 100 GAF-044-02-01 01/13/04
PRI Asphalt Technologies,Inc. TAS 100 GAF-098-02-01 11/08/05
PRI Asphalt Technologies,Inc. TAS 100 GAF-101-02-01 11/09/05
PRI Asphalt Technologies,Inc. TAS 100 GAF-116-02-02 03/23/06
PRI Asphalt Technologies,Inc. TAS-100 ELK-083-02-01 10/16/02
ELK-084-02-01 10/15/02
ELK-085-02-01 10/14/02
ELK-086-02-01 10/24/02
ELK-087-02-01 10/21/02
ELK-088-02-01 10/16/02
ELK-107-02-01 10/09/03
ELK-108-02-01 10/09/03
ELK-109-02-01 10/09/03
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61G20-3 of the Florida Administrative Code.
NOA No.: 16-0811.11
MAMFO�DE Expiration Date: 02/21/22
Approval Date: 02/09/17
Page 3 of 6
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail'A',attached.
5. Nailing shall be in compliance with Detail B',attached.
LABELING
Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of
manufacturing facility,and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade
County Product Control Seal as shown below.
MIAMEDADE COUNTY
��ffjjjaeyjqsj
BUILDING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
NOA No.: 16-0811.11
Miar+Foa�counmr Expiration Date:02/21/22
JAPPROVED,
Approval Date:02/09/17
Page 4 of 6
DETAIL A
COURSE LAYOUT
DECK
FULL
5th
17"OFF 4th
11" OFF 3rd
6" OFF 2nd
FULL 1 st
NOA No.: 16-0811.11
Expiration Date: 02/21/22
Approval Date: 02/09/17
Page 5 of 6
DETAIL B
OVERALL DIMENSIONS AND NAILING PATTERN
39-3/811
(1 m)
14-12"-17-12" 14-12"-17-12"
(368-"5mm) (3ffi-"5MM) qa,'l guide line
13-1/4" 6-12"-9-1/7' 6-1 rr'-9-1/T
(tom-2at".n) (1�-Mtmm) 4'-61/4'
(337rrm1 - rmr-1S9rM1)
7?-2-ta' from bottom of shingle
ow (13-
elf seal
adhesive
on back
ENHANCED NAILING PATTERN - six nails per shingle*
required by some local codes and required for enhanced wind coverage on certain products.
See limited warranty for detaiis.
These shingles MUST be nailed a nominal 6" (152mm)from bottom of
of shingle, above the cut outs, as shown. Nails must not be exposed.
END OF THIS ACCEPTANCE
F c NOA No.: 16-0811.11
Expiration Date: 02/21/22COVED
Approval Date: 02/09/17
Page 6 of 6
Business & Professional Regulation
SM Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FSC Staff BCIS Site Nap Lima Search
~00 APPMVal
dopr (P USER:Publk User
Product Approval Menu>Product or Apyhcatlon Search>Application List
Search Criteria Refine Search
Code Version 2017 FL* 5259
4pplicadon Type ALL Product Manufacturer ALL
Category ALL Subcategory ALL
Application Status ALL Compliance Method ALL
Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL
Product Model,Number or Name ALL Product Description ALL
Approved for use in HVHZ ALL Approved for use outside HVHZ ALL
Impact Resistant ALL Design Pressure ALL
Other ALL
Search Results-Applications
Manufacturer Validated 8v Status
F15259-R27 {Revision POLVGLASS USA John W.Knezevich,PE Approved
H sr tory Category:Roofing (954)772-6224
Subcategory:Underlayments
'Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
Contact Us::2601 Blair Stone Road,Tallahassee FL 31399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statemen[::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395. 'Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
They have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee
under Chapter 4S5,F.S-,please dick here.
Product Approval Accepts:
®U ® t:Y 0
Credit Card
Safe
Y
Business + Regulation
HM Hone Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FOC Staff BCIS Site Map Lima Search
Product Approval
d r %ff USER:Public User
Product Approval Menu>Product or Application Search>Application List>App/kation DOW11
• , FL# FL5259-R27
Application Type Revision
Code Version 2017 RECEIVED
Application Status Approved
Comments JAN 2 4 2018
Archived ST. Lucie County, Permitting
Product Manufacturer POLYGLASS USA
Address/Phone/Email 150 Lyon Drive
Fernley,NV 89408
(570)384-1230 Ext 242
jakins@polyglass.com
Authorized Signature James Akins
jakins@polyglass.com
Technical Representative Maury Alpert
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach,FL 33442
(912)429-8610
MAlpert@polyglass.com
Quality Assurance Representative Ariel Lender
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach,FL 33442
(954)233-1230
ALender@polyglass.com
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/05/2018
Validated By John W.Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of independence F1,52S9 R27 COI 2017 01 COI Niernmen.edf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM D226 2009
ASTM D6164 2011
ASTM D6222 2011
FM 4474 2011
FRSA/TRI April 2012 2012
TAS 103 1995
TAS 110 2000
UL 1897 2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method MebW 1 Option D
Date Submitted 09/14/2017
Date Validated 09/15/2017
Date Pending FBC Approval 09/18/2017
Date Approved 12/12/2017
Summary of Products
FL# Model,Number or Name Des-fption
- —-- - — --
5259.1 Polyglass Roof Underlayments Roofing underlayments
F
Limits of Use Znstn ttkm Znsbwcdons
Approved for use in HVHZ:No FL5259 R27 11 2017 09 FINAL ER POLYGLASS UNDFRLAYMENTS FL5259-
Approved for use outside HVHZ: Yes R27,12
df
Impact Resistant:N/A Verified By:Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5 1 Created by Independent Third Party: Yes
Other: 1-) The design pressure in this application j Evaluation Reports
relates to one particular underlayment system(over FL5259 R27 AE 2017 09 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
concrete deck)for use under foam-on tile systems ;R27f
(where the underlayment forms part of the load-path). Created by Independent Third Party: Yes
Refer to ER Section 5.6.4 for other systems,other deck
types and associated maximum design pressures.2.)
Refer to ER Section 5 for other limits of use.
Back C
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EED employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395. *Pursuant to
Section 455.275(1),Flonda Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public. To determine if you are a licensee
under Chapter 455,F.S.,please dick here.
Product Approval Accepts:
M E� W_ FE M
Credit Card
Safe
EXTERIOR RESEARCH&DESIGN,U.C.
Certificate of Authorization#9503
TRINITY ERD 353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
(203)262-9245
EVALUATION REPORT
Polyglass USA, Inc. Evaluation Report P12060.02.09-R23
150 Lyon Drive FL5259-1127
Fernley, NV 98408 Date of Issuance:02/24/2009
(570)384-1230 Revision 23:09/14/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 14.
Prepared by:
�`oQ
z��O��p-S41'M •'�
i.7..A�' - 'Clr...
Robert J.M. Nieminen P.E. �gt,.s+�.•�c The facsimile seal appearing was authorized by Robert Nieminen,
Florida Registration No.59166,Florida DCA ANE1983 P.E.on 09/14/2017. This does not serve as an electronically
signed document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the S'h Edition (2014) Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Prope Standard Year
1504.3.1 Wind Uplift FM 4474 2011
1504.3.1 Wind Uplift UL 1897 2012
1507.2.3/1507.1.1 Physical Properties ASTM D226 2009
1507.2.4/1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015
1507.3.3 Physical Properties FRSA/TRI April 2012 2012
1507.11.2 Physical Properties ASTM D6164 2011
1507.11.2 Physical Properties ASTM D6222 2011
1523.6.5.2.1 Physical Properties TAS 103 1995
TAS 110 Accelerated Weathering TAS 110 2000
3. REFERENCES:
Entity Examination Reference Date
FM Approvals(TST 1867) Wind Uplift 3004091 01/12/2000
PRI(TST 5878) Physical Properties PRIO1111 04/08/2002
PRI(TST 5878) Physical Properties PUSA-005-02-01 01/31/2002
PRI(TST 5878) Physical Properties PUSA-013-02-01 12/23/2002
PRI(TST 5878) Physical Properties PUSA-013-02-02 12/23/2002
PRI(TST 5878) Physical Properties PUSA-013-02-03 12/23/2002
PRI(TST 5878) Physical Properties PUSA-018-02-01 07/14/2003
PRI(TST 5878) Physical Properties PUSA-028-02-01 07/13/2005
PRI(TST 5878) Physical Properties PUSA-033-02-01 01/12/2006
PRI(TST 5878) Physical Properties PUSA-035-02-01 09/29/2006
PRI(TST 5878) Physical Properties PUSA-055-02-02 12/10/2007
PRI(TST 5878) Physical Properties PUSA-061-02-02 01/28/2008
PRI(TST 5878) Physical Properties PUSA-076-02-01 02/22/2008
PRI(TST 5878) Physical Properties PUSA-083-02-01 04/14/2008
PRI(TST 5878) Physical Properties PUSA-088-02-01 07/29/2009
MTI(TST 2508) Physical Properties JX201-17A 04/01/2008
MTI(TST 2508) Physical Properties RX14E8A 01/29/2009
ERD(TST 6049) Physical Properties 11752.09.99-1 02/08/2000
ERD(TST 6049) Wind Uplift 11757.08.01-1 08/13/2001
ERD(TST 6049) Wind Uplift 11776.06.02 01/16/2003
ERD(TST 6049) Physical Properties 02200.07.03 07/14/2003
ERD(TST 6049) Wind Uplift P1740.01.07 01/04/2007
ERD(TST 6049) Physical Properties P5110.04.07-1 04/11/2007
ERD(TST 6049) Wind Uplift P9260.03.08 03/21/2008
ERD(TST 6049) Physical Properties P13450.08.09 08/13/2009
ERD(TST 6049) Wind Uplift P30540.11.09-111 11/30/2009
ERD(TST 6049) Physical Properties P11030.11.09-1 11/30/2009
ERD(TST 6049) Wind Uplift P11030.11.09-2 11/30/2009
ERD(TST 6049) Physical Properties P11030.11.09-3 11/30/2009
ERD(TST 6049) Physical Properties P33360.06.10 06/25/2010
ERD(TST 6049) Physical Properties P33370.03.11 03/02/2011
ERD(TST 6049) Physical Properties P33370.04.11 04/26/2011
ERD(TST 6049) Physical Properties P37300.10.11 10/19/2011
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R23
Certificate ofAuthanzatmm#9503 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-1127
Polyglass Roof Underlayments;(570)384-1230 Revision 23:09/14/2017
Page 2 of 14
TRINITY ERD
Entity Examination Reference Date
ERD(TST 6049) Physical Properties P40390.08.12-1 08/06/2012
ERD(TST 6049) Physical Properties P40390.08.12-2 08/07/2012
ERD(TST 6049) Physical Properties C41420.09.12-3 09/11/2012
ERD(TST 6049) Wind Uplift P39680.03.13 03/04/2013
ERD(TST 6049) Physical Properties P45370.04.13 04/26/2013
ERD(TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013
ERD(TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013
ERD(TST 6049) Wind Uplift P41630.08.13 08/06/2013
ERD(TST 6049) Wind Uplift P117S1.05.03-R1 11/26/2013
ERD(TST 6049) Wind Uplift P11781.11.03-R1 11/26/2013
ERD(TST 6049) Physical Properties P45270.05.14 05/12/2014
ERD(TST 6049) Physical Properties 6020.07.14-1 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-2 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-3 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-4 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-5 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-6 09/08/2014
ERD(TST 6049) Physical Properties P46520.10.14 10/03/2014
ERD(TST 6049) Physical Properties P44360.10.14 10/07/2014
ERD(TST 6049) Physical Properties P43290.10.14 10/17/2014
ERD(TST 6049) Physical Properties PLYG-SC7550.03.15 03/24/2015
ERD(TST 6049) Physical Properties P40390.04.15 04/03/2015
ERD(TST 6049) Physical Properties PLYG-SC8080.05.15-1 05/20/2015
ERD(TST 6049) Wind Uplift PLYG-SC8905.05.16-1 05/17/2016
ERD(TST 6049) Physical Properties PLYG-SC8080.07.16 07/16/2016
ERD(TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016
ERD(TST 6049) Physical Properties PLYG-SC13040.12.16 12/27/2016
ERD(TST 6049) Physical Properties PLYG-SC11900.03.17 03/10/2017
ERD(TST 6049) Physical Properties PLYG-SC12115.08.17 08/08/2017
ICC-ES(EVL 2396) IBC Compliance ESR-1697 11/01/2014
Miami-Dade(CER 1592) HVHZ Compliance NOA 14-0717.08 01/22/2015
Polyglass USA Manufacturing Affidavit Products Current 02/18/2009
Polyglass USA P/L Affidavit Mule-Hide Cross Ltg 03/01/2008
Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011
UL,LLC.(QUA962S) Quality Control Service Confirmation Exp.10/05/2018
4. PRODUCT DESCRIPTION:
4.1 Mechanically Fastened Underlayments:
4.1.1 Elastobase is a fiberglass reinforced,SBS modified bitumen base sheet.
4.1.2 Elastobase P is a polyester-reinforced,SBS modified bitumen base sheet.
4.1.3 Polyglass G2 Base is a fiberglass-reinforced,asphaltic base sheet.
4.1.4 Polyglass APP Base is a fiberglass-reinforced,APP modified bitumen base sheet.
4.2 Self-Adhering Underlayments:
4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,surfaced
with polyolefinic film surface;meets TAS 103,
4.2.2 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced, with an
aggregate surface;meets ASTM D1970.
4.2.3 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with a
polyester fabric surface;meets ASTM D1970 and TAS 103.
Exterior Research and Design,U.C. Evaluation Report P12060.02.09-R23
Certificate of Authorization#9503 6`"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments;(570)3841230 Revision 23:09/14/2017
Page 3 of 14
TRINITY ERS
4.2.4 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester
reinforced,with a granular surface; meets ASTM D1970 and TAS 103.
4.2.5 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester
fabric surface;meets ASTM D1970 and TAS 103.
4.2.6 Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet (FR) are polyester
reinforced,APP modified bitumen cap sheets;meet FRSA/TRI April 2012.
4.2.7 Polystick Dual Pro' is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass
reinforced,with a polyester fabric surface;meets ASTM D1970.
4.2.8 Polystick Tile Pro' is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass
reinforced,with a polyester fabric surface;meets ASTM D1970 and TAS 103.
4.2.9 Polystick MU-X is a nominal 54-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970 (See Section
5.8).
4.3 Mechanically Fastened and/or Bonded Underlayments:
4.3.1 Elastoflex G TU is a polyester reinforced, modified bitumen tile underlayment composed of a sand-surfaced SBS
modified bitumen back-side and granule-surfaced APP modified bitumen top-side. Elastoflex G TU is for use as an
alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap Sheet" in the "Two Ply
System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened or adhered tile roof systems.
4.3.2 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced,SBS modified bitumen cap sheets; meet ASTM D6164.
Elastoflex S6 G and Elastoflex S6 G FR are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380,
Class M)in the"Single Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened tile roof systems.
Elastoflex S6 G is for use as an alternate to Hot Asphalt applied"Cap Sheet" in the"Two Ply System"from FRSA/TRI
April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex S6 G FR is for use as an
alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath
mechanically fastened tile roof systems.
4.3.3 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222.
Polyflex G is for use as an alternate to Heat Applied "Cap Sheet' in the"Two Ply System"from FRSA/TRI April 2012
(04-12)beneath mechanically fastened or adhered tile roof systems. Polyflex G FR is for use as an alternate to Heat
Applied "Cap Sheet' in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened the
roof systems.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R23
Certificate of Authorization#9503 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-RZ7
Polyglass Roof Underlayments;(570)3841230 Revision 23:09/14/2017
Page 4 of 14
TRINITY ERD
5.5 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Underlayment Asphalt Shingles Nail-On Tile Foam-On Tile Metal wood Shakes Slate
&Shingles
Elastobase Yes Yes Yes Yes Yes Yes
(Base Sheet in 2-ply system) (Base Sheet in 2-py system)
Elastobase P Yes Yes Yes Yes Yes Yes
(Base Sheet in 2-ply system) (Base Sheet in 2-ply system)
Polyglass G2 Base No Yes Yes No No No
(Base Sheet in 2-ply system) (Base Sheet in 2-ply system)
Polyglass APP Base No Yes Yes No No No
(Base Sheet in 2-ply system) (Base Sheet in 2-ply system)
Polystick MTS Yes Yes No Yes Yes Yes
Polystick IR-Xe Yes No No No Yes Yes
Polystick TU P Yes Yes Yes (See 5.5.1) No Yes Yes
Polystick TU Plus Yes Yes Yes (See 5.5.1) Yes Yes Yes
Polystick TU Max No Yes Yes (See 5.5.1) Yes No No
Polystick Dual Pro Yes No No Yes Yes Yes
Polystick Tile Pro Yes Yes Yes (See 5.5.1) Yes Yes Yes
Polystick MU-X Yes No No Yes Yes Yes
Elastoflex S6 G Yes Yes Yes (See 5.5.1) No Yes Yes
Elastoflex S6 G FR Yes Yes No No Yes Yes
Elastoflex G TU Yes Yes Yes (See 5.5.1) No Yes Yes
Polyflex G Yes Yes Yes (See 5.5.1) No Yes Yes
Polyflex G FR Yes Yes No No Yes Yes
Polyflex SAP or SAP FR Yes Yes Yes (See 5.5.1) No Yes Yes
Mule-Hide SA-APP Cap Sheet Yes Yes Yes (See 5.5.1) No Yes Yes
or SA-APP Cap Sheet(FR)
5.5.1 "Foam-On Tile"is limited to use of the following Approved tile adhesives/underlayment combinations.
TABLE LA.ALLOWABLE TILE ADHESIVE/UNDERLAYMENT COMBINATIONS)
Adhesive Florida Product Underlayments
Approval
DAP Foam Touch'n Seal Storm Bond Roof FL14506 Polystick TU Plus,Polystick TU Max
Tile Adhesive
Dow TileBond— FL22525 Polystick TU P,Polystick TU Plus,Polyflex SAP or Tile Pro
Polystick TU P,Polystick TU Plus,Polystick TU Max,Polystick Tile Pro,
ICP Adhesives Polyset*AH-160 FL6332 Elastoflex G TU,Elastoflex S6 G,Polyflex G,Polyflex SAP,Polyflex SA Cap FR,
Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR)
Polystick TU P,Polystick TU Plus,Polystick TU Max,Polystick Tile Pro,
ICP Adhesives Polyset®RTA-1 FL6276 Elastoflex G TU,Elastoflex S6 G,Polyflex G,Polyflex SAP,Polyflex SA Cap FR,
Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR)
Polyglass PolyLok Roof Tile Adhesive FL17855 Polystick TU Plus or Polystick TU Max
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approvo/for Overturning Moment Resistance Performance.
Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-R23
Certificate of Authorization#9503 6°1 EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments;(S70)384-1230 Revision 23:09/14/2017
Page 5 of 14
TRINITY ERD
5.6 Allowable Substrates:
5.6.1 Direct-Bond to Deck:
Polystick(all variations), Dual Pro,Tile Pro, Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet
(FR)self-adhered to:
➢ New untreated plywood;ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing
plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System' Panels
(designed and installed to meet wind loads for project).
Note:Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or
OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ ASTM D41 primed structural concrete.
Polyflex G or Polyflex G FR torch-applied to:
➢ ASTM D41 primed structural concrete.
5.6.2 Bond-to-insulation:
Polystick(all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self-adhered
to:
➢ ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck
DuraGuard; Dens Deck Prime;or SECUROCK Gypsum-Fiber Roof Board.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board.
Polyflex G or Polyflex G FR torch-applied to:
➢ ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile
systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FBC Section 1504.3.1.
5.6.3 Bond to Mechanically Attached Base Layer:
Polystick (all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or
Tile Pro self-adhered to:
➢ ASTM D226,Type I or II felt;Elastobase; Elastobase P or Mule-Hide Nail Base.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ ASTM D226,Type I or II felt;Elastobase; Elastobase P,Mule-Hide Nail Base or Polyglass G2 Base.
Polyflex G or Polyflex G FR torch-applied to:
➢ Elastobase; Elastobase P, Mule-Hide Nail Base, Polyglass G2 Base or Polyglass APP Base.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam-on tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12),Appendix A,Table 1, or as listed in Section 5.6.4 herein,or as tested in
accordance with FBC Section 1504.3.1.
Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-R23
Certificate of Authorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FLS259-1127
Polyglass Roof Underlayments;(570)3841230 Revision 23:09/14/2017
Page 6 of 14
�TRINITY ERD
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam-on tile systems, where the underlayment
forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRl April 2012 (04-12)and are used in foam-on tile applications. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure
divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04-
12),Appendix A,Table 1A or FBC 1609 for determination of design wind loads.
#1 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
#2 Maximum Design Pressure=-97.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x
1W ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
#3 Maximum Design Pressure=-105 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x
lid"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
#4 Maximum Design Pressure=-135 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional)PG100 or ASTM D41
Joints: Min.4-inch wide strips of Elastoflex SA-V over all plywood joints.
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
#5 Maximum Design Pressure=-315 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max,Tile Pro, Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap
Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
#6 Maximum Design Pressure=-622.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#7 Maximum Design Pressure=-30.0 psf*:
Deck: Min.15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch c.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
#8 Maximum Design Pressure=-37.5 psf*:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R23
CerbficateofAuthorizawn#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments;(570)384-1230 Revision 23:09/14/2017
Page 7 of 14
TRINITY ERD
#9 Maximum Design Pressure=-37.5 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One(1)or two(2)layers ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
#10 Maximum Design Pressure=-45 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One(1)layer ASTM D226,Type I I felt
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c.at the 2-inch wide side laps and 4-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex G TU,applied in full mopping of hot asphalt.
#11 Maximum Design Pressure=-45 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Two(2)layers ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 9-inch o.c.at the 2-inch wide side laps and 9-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot
asphalt.
#12 Maximum Design Pressure=-45 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.at the 2-inch wide side laps and 18-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#13 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#14 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
#15 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#16 Maximum Design Pressure=-60 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R23
Certificate of Authorization 119503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments,(570)384-1230 Revision 23:09/14/2017
Page 8 of 14
TRINITY ERS
#17 Maximum Design Pressure=-60 PSE
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#18 Maximum Design Pressure=-67.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underlayment)
Fasteners: 12 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch-applied or Polyflex G, torch-
applied.
#19 Maximum Design Pressure=-75 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underlayment)
Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates, OMG Roofgrip#14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MARX Cap
Fasteners
Spacing: 10-inch o.c.at the 4-inch wide side laps and 10-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch-applied or Polyflex G, torch-
applied.
#20 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#21 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#22 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
#23 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underlayment)
Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates, OMG Roofgrip#14 with
CMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c_at four(4)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or torch-applied or Polyflex G, torch-
applied.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R23
Certificate of Authorization#9503 6H EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-1127
Polyglass Roof Underlayments;(570)3841230 Revision 23:09/14/2017
Page 9 of 14
TRINITY ERD
#24 Maximum Design Pressure=-97.5 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c.at the 4-inch wide side laps and 4-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
#25 Maximum Design Pressure=-105 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#26 Maximum Design Pressure=-120 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#27 Maximum Design Pressure=-120 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt
5.6.4.1 All other direct-deck, adhered Polyglass underlayment systems beneath foam-on tile systems carry a Maximum
Design Pressure of-45 psf.
5.6.4.2 For mechanically attached Base Sheet,the maximum design pressure for the selected assembly shall meet or exceed
that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density
designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked
with an asterisk' carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January
2016)for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days
after installation.
Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after installation.
Polystick MTS,TU P,TU Plus,TU Max, Dual Pro,Tile Pro or Elastoflex G TU shall not be left exposed for longer than
180-days after installation.
Polyflex SAP or SAP FR, or Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering is to be adhesive-set tile, in which case the maximum exposure is 30
days.
Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the
prepared roof covering is to be adhesive-set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum
exposure is 180 days.
5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226
roofing felt in a dry condition,tested at standard laboratory conditions. Agreement between purchaser and seller,as
set forth in Section 4.3,Note 1 of ASTM D1970-15,should be established as to slip resistance.
Exterior Research and Design,LLC. Evaluation Report P32060.02.09-R23
CertificateofAuthorization#9503 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments;(570)384-1230 Revision 23:09/1412017
Page 10 of 14
()OTRINI'TY 'ERD
5.9 Tile Slippage Limitations(TAS 103 per FRSA/TRI April 2012(04-12)):
When loading roof tiles on the underlayment in direct-deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS
Underlayment Tile Profile Staging Method Maximum Slope
Elastoflex G TU Flat 10-tile stack 7:12
Lugged 8-tile stack(6 over 2) 6:12
Elastoflex S6 G or S6 G FR Flat or Lugged 6-tile stack(4 over 2) 4:12
Polystick MTS Flat or Lugged Prohibited without battens N/A
Polystick Tile Pro Flat or Lugged 6-tile stack(4 over 2) 7:12
Flat 6-tile stack(4 over 2)or 10-tile stack 7:12
Polystick TU Max Lugged 6-tile stack(4 over 2) 7:12
Lugged 10-tile stack 6:12
Polystick TU P Flat 6-tile stack(4 over 2) 6:12
Lugged 6-tile stack(4 over 2) 4:12
Polystick TU Plus Flat or Lugged 6-tile stack(4 over 2) 7:12
Flat or Lugged 10-tile stack 6:12
Polyflex G or G FR Flat or Lugged 6-tile stack(4 over 2) 4:12
Polyflex SA P or SA P FR Flat or Lugged 6-tile stack(4 over 2) 4:12
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application,and prime the substrate(if applicable).
6.3 Elastobase,Elastobase P or Mule-Hide Nail Base:
6.3.1 Non-Tile Applications:
Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
Elastobase, Elastobase P or Mule-Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA
P FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self-adhered, Elastoflex G TU, Elastoflex S6 G or
Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR,torch applied. Roof cover limitations are those are
those associated with the top-layer underlayment,as set forth in Table 1.
6.3.2 Tile Applications:
Elastobase,Elastobase P or Mule-Hide Nail Base are limited to use as a mechanically attached base sheet in the"Two
Ply System"from FRSA/TRI April 2012(04-12). Reference is made to Table 1 and Section 5.6.4 herein,coupled with
FRSA/TRI April 2012(04-12)Installation Manua).
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-1123
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-1127
Polyglass Roof Underlayments;(570)3841230 Revision 23:09/14/2017
Page 11 of 14
TRINITY ERD
6.4 Polystick MTS,IR-Xe,TU P,TU Plus,TU Max,Dual Pro,Tile Pro or MU-X or Polyflex SAP,Polyflex SAP FR,Mule-Hide
SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR):
6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table 1507.1.1
for the type of prepared roof covering to be installed.
6.4.2 Direct-to-Deck with Mechanically Fastened Roof Covers:
All self-adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule-Hide SA-APP
Cap Sheet or SA-APP Cap Sheet(FR)should be back-nailed in selvage edge seam in accordance with Polyglass/Mule-
Hide Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring-shank type with a minimum 1-inch diameter
metal disk or Simplex-type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back-nailed
using the above noted fasteners and spacing, in area marked "nail area, area para clavar"on the face of membrane.
The head lap membrane is to cover the area being back-nailed.
All seal-lap seams (selvage laps) must be
firmly rolled with a minimum 28 Ib. hand
roller to ensure full contact and adhesion.
For Dual Pro and Tile Pro, align the edge of
the top sheet to the end of the glue pattern
(the sheet will overlap the fabric).
View of Ovelap Seam of Dual Pro and Tile Pro
All over-fabric and over-granule end-laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified
Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap.
Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets,exposed valleys,
or exposed roof to wall details
Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or
Polyglass PG500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the
Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be
installed in a water shedding manner.
All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 40-Ib weighted-roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches,laps(min.28 Ib roller)or small areas of the
roof that are not accessible to a large roller or broom.
6.4.3 Tile Applications(not allowed for Polystick Dual Pro,!R-Xe or Polystick MU-X):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For mechanically fastened tile roofing over 2-ply system,consisting of Base Sheet and self-adhering top sheet(s), Base
Sheet fastening shall be not less than FRSA/TRI April 2012(04-12),Table 1.
For adhesive-set tile applications,refer to Section 5.6.4 herein.
For nail-on tile systems over Polystick MTS,battens are required for loading/staging of the tile.
6.4.4 Two(2)Ply Underlayment Systems:
Polystick MTS followed by Polystick MTS,TU P,TU Plus,TU Max,Tile Pro,MU-X or Polyflex SAP is allowable for use
under mechanically attached prepared roof systems. Limits of use are those associated with the top-layer material.
This is not a requirement,but is allowable if a 2-ply underlayment system is desired.
Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-R23
Certificate ofAuthonzanon#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R27
PoWlass Roof Underlayments;(57013841230 Revision 23:09/14/2017
Page 12 of 14
TRINITY ERa
6.5 Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR:
6.5.1 Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR shall be installed in compliance with current Polyglass published
installation requirements. For use in tile applications:
✓ Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single
Ply System" from FRSA/TRI April 2012(04-12)beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the'Two Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in the"Single Ply
System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened the roof systems or the Hot Asphalt
applied "Cap Sheet" in the"Two Ply System"from FRSA/TRI April 2012(04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G FR is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in the"Single
Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet"in the'Two Ply System"from FRSA/TRI April 2012(0412)beneath mechanically fastened tile
roof systems.
6.5.2 For hot-asphalt-applications,Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR shall be fully asphalt-applied to the
substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end-laps minimum 6-inch wide, off-set
minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt
with asphalt extending approximately 3/8-inch beyond the lap edge.
6.6 Polyflex G or Polyflex G FR:
6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements.
For use in tile applications:
✓ Polyflex G is for use as an alternate to the Heat Applied "Cap Sheet" in the`Two Ply System"from FRSA/TRI April
2012(0412)beneath mechanically fastened or adhered tile roof systems(Base Sheet Limited per 5.6.3).
✓ Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI
April 2012(0412)beneath mechanically fastened the roof systems(Base Sheet Limited per 5.6.3).
6.6.2 Polyflex G or Polyflex G FR shall be fully torch-applied to the substrates noted in Section 5.6. Side laps shall be
minimum 3-inch and end-laps minimum 6-inch wide, off-set minimum 3 feet from course to course. Side and end
laps shall be fully heat-welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap
edge.
6.7 Tile Staeina:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to
Table 2 herein,and Polyglass published requirements for tile staging.
6.7.2 Battens and/or Counter-battens,as required by the tile manufacturer and FRSA/TRI April 2012(04-12) must be used
on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or sail-
boards,to prevent tile sliding and/or damage to the underlayment during the loading process.
6.7.3 Polyglass specifies the minimum cure time after installation of self-adhering membranes and before loading of
roofing tiles is forty-eight(48)hours.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R23
Cert#lcateofAuthonzation#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments;(570)384-1230 Revision 23:09/14/2017
Page 13 of 14
-, TRINITY ERD
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C.61G20-3 QA requirements. The following
plants have qualified products under their respective physical properties specifications.
Plant Specification Emdu—CALS1
Fernley,NV,Hazleton,PA&Winter Haven,FL ASTM D1970 Polystick MU-X
Hazleton,PA M-D 13-0004 Elastoflex G TU
ASTM D1970 Polystick IR-Xe
Hazleton,PA&Winter Haven,FL ASTM D1970&TAS 103 Polystick TU Plus
ASTM D1970&TAS 103 Polystick TU Max
Tuscaloosa,AL ASTM D4601,Type II Polyglass G2 Base
ASTM D226(physicals) Elastobase,Elastobase P
ASTM D6509 Polyglass APP Base
TAS 103 Polystick MTS
ASTM D1970&TAS 103 Polystick TU P
Winter Haven,FL FRSA/TRI April 2012 Polyflex SAP,Polyflex SA P FR
ASTM D1970 Polystick Dual Pro
ASTM D1970&TAS 103 Polystick Tile Pro
ASTM D6164 Elastoflex S6,Elastoflex S6 G FR
ASTM D6222 Polyflex G,Polyflex G FR
9. QUALITY ASSURANCE ENTITY:
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R23
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-RZ7
Polyglass Roof Underlayments;(570)384-1230 Revision 23:09/14/2017
Page 14 of 14