HomeMy WebLinkAboutBuilding Permit ApplicationALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date:
Permit Number:
Building Permit Application
Planning and Development Services
Building and Code Regulation Division
2300 Virginia Avenue, Fort Pierce FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential X
PERMIT APPLICATION FOR: Plumbing
Address: 8104 ALISTER PLACE
Legal Description: POD 26 AT THE RESERVE PHASE 1 CYPRESS POINT LOT 26 (OR 3496-416)
Property Tax ID #: 3327-707-0030-000-2
Site Plan Name:
Project Name:
Setbacks Front Back:
Right Side: Left Side:
REPLACEMENT OF TWO (2) 50 GALLON HEATERS WITH PERMIT
Additional work to ne nertormea
11HVAC 1:1_ Gas Tank
11 Electric ❑✓ Plumbing
Total Sq. Ft of Construction:
Cost of Construction: $ 2,140.00
under this permit — cl
E]Gas Piping
OSprinklers
aii apply:
_ Shutters
ElGenerator
S . Ft. of First Floor:
Utilities. _ Sewer E-1 Septic
Name MARTIN & MARYANN MARSHALL
Address: 8104 ALISTER PLACE
City: PORT ST LUCIE State: FL
Zip Code: 34986 Fax:
Phone No. 417-231-1441
E -Mail:
Fill in fee simple Title Holder on next page (if different
from the Owner listed above)
Lot No._
Block No.
❑ Windows/Doors
❑ Roof
Name: RICHARD BASSOFF
Building Height:
Comnanv: ADMIRAL PLUMBING SERVICES, LLC
Address: 2895 JUPITER PARK DR #700
City: JUPITER State: FL
Zip Code: 33458 Fax:
Phone No. 561 746-1180
E -Mail: christine@theadmiralplumber.com
State or County License: CFC 1426115
If value of construction is $2500 or more, a RECORDED Notice of Commencement is required.
DESIGNER/ENGINEER: Not Applicable
Name:
Address:
City: State:
Zip: Phone:
FEE SIMPLE TITLE HOLDER:
Name:
Address:
City:
Zip: Phone: _
Not Applicable
:MORTGAGE COMPANY: Not Applicable
Name:
Address:
.City: State:
Zip: Phone:
BONDING COMPANY: Not Applicable
Name:
Address:
,City:
Zip: Phone -
1 certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a f tll concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for
improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite
before the 'section. if you intend to obtain financing, consult w'th lender or an attorney before
commen ng-wor ordine your Notice of Commencement.,
n
_ Signature of Owner/ Lessee/Agent
STATE OF FLORIDA
COUNTY OF Pmm wAcH
The forgoing instru ent was acknowledged afore me
this -day of Ni 20 Y by
(Name of person acknowledging)
ature of Notary Public- State of Florida )
nally Known ✓ OR Produced Identification
of Identification Produced
Commission No.
Revised 07/15/201
Notej" state of FW66
Susan Clark Costa
` Expires 1111312020
STATE OF SWRIDA
COUNTY OF PALM MACH
The forgoing instru ent was acknowledged before me
this day of 20 I fi by
(Name of person acknowledging)
(Signature of Notary Public- State of Florida )
Personally Known OR Produced Identification _
Type of Identification Produced
Commission No. ry Publ(b880 of F10011
Susan Clark Costa
,s My Corm Wsim OO 032841
REVIEWS
FRONT
ZONING
SUPERVISOR
PLANS
VEGETATION
SEA TURTLE
MANGROVE
COUNTER
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
DATE
COMPLETE
INITIALS
Jim
Invoice 161428
Invoice Date 1/23/2018
Terms COD
Completed Date 1/23/2018
Customer PO
Billing Address
Job Address
MARTIN MARSHALL
MARTIN MARSHALL
8104 Alister Place
8104 Alister Place
Port St. Lucie, FL 34986 USA
Port St. Lucie, FL 34986
USA
Description of Work
REPLACEMENT OF TWO (2) 50 GALLON HEATERS - ONE IN GARAGE AND ONE IN MASTER BATHROOM WITH PERMIT
Task # Description
Quantity Your Price Your Total
T42610 STANDARD 50 GALLON ELECTRIC WATER HEATER -PLUS PERMIT AND UPGRADES
2.00 $875.00
$1,750.00
A14860 WATER EXPANSION TANK (TANK ONLY)
2.00 $145.00
$290.00
A13210 3/4" BALL VALVE - CXC
2.00 $75.00
$150-00
A99534 WATER HEATER PERMIT
1.00 $175.00
$175.00
D70657 COURTESY DISCOUNT
1.00 $-200.00
$-200.00
D70652 COUPONS DISCOUNT FROM WEBSITE
1.00 $-25.00
$-25.00
Paid On Type Memo
Amount
1/23/2018 American Express
$2,140.00
Sub -Total
$2,140.00
Tax
$0.00
Total Due
$2,140.00
Payment
$2,140.00
Balance Due $0.00
Terms: ALL ESTIMATES ARE GOOD FOR 30 DAYS. All material is guaranteed to be as specified. All work is to be completed in a professional manner
according to standard practices. Any alteration or deviation from above specifications involving extra costs will be executed only upon written orders and
will become an extra charge over and above the estimate. All agreements contingent upon delays, beyond our control. All payments are due upon
completion of installation. All payments not received upon completion are subject to 1 1/2% service charge per month, or the maximum rate permitted by
law, whichever is less. In the event of non-payment, all costs incidental to collection, including without limitation reasonable attorney's fees shall be added
to the unpaid balance. "*DEPOSITS FOR WORK REQUIRING PERMIT: In the event a deposit is given requiring a permit and the work is cancelled after
permit is pulled, refund will be given minus any permit and administrative fees that were paid by Admiral Plumbing.
PLEASE MAIL ALL PAYMENTS TO:
2895 JUPITER PARK DR #700
JUPITER, FL 33458
(561) 746-1180
I hereby agree to have Admiral Plumbing complete the work described for the proposed price regardless of the time it takes to complete
the work.
I hereby acknowledge the satisfactory completion of the above described work.
^/�\ /_�M
I authorize Admiral Plumbing Services, LLC to charge the agreed amount to my credit card provided herein. I agree that I will pay for this
purchase in accordance with the issuing bank cardholder agreement.
t
,^n. E �
t
_ ` � . }
1
i
j
i �
_ �
I �
� �
I
I �
I
i
�
t
i �
!
The now degree of comfort'
Professional Classic'" Specifications
Residential Electric
.` Water Professional Classic Water Heaters
Energy Factor based on D.O.E. (Department of Energy) test procedures.
t System Sentinel optional. Add EC1 to the end of the model number. System Sentinel not available on single
element models, available on dual element models only. System Sentinel not available In excess of 5 kW on
208 V models.
Water heater dimensions prior to installing insulation blanket that is included with water heater.
• Heaters furnished with standard 240 volt AC, single phase non -simultaneous widrly, and 4500 watt upper and lower heating
elements.
• If heating elements of different wattages than those shown are demanded by zone requirements, they must be
specifically requested.
• Single element models available on special order (6000W max.). Substitute "1" for "2" in model number.
• Special Wiring Options - A limited number of special wiring options are available. Consult factory for price and availability.
•
AN models equipped with heat traps.
Recovery = wattage/2.42 x temp. rise °F.
Example: 450OW = 21 GPH
2.42 x 90°
Recovery calculations used are based on 4500 watt elements used in non -simultaneous operation.
Bit
HOT
WATER COLD
CONNECTION WATER
RELIEF VALVECONNECTION
CONNECTION I� eNnno
ROD
DIAMCETER
A
B
WATER CONNECTIONS ALL 314" N.P.T.
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Water Heating • 101 Bell Road
Montgomery, Alabama 36117-4305 it www.rheam.com
PRINTED IN U.S.A. 09/15 WP FORM NO. PROE RH N Rev. 2
DESCRIPTION
FEATURES
ROUGHING IN DIMENSIONS (SHOWN IN INCHES)
ENERGY INFO.
GAL MODEL
TYPE CAP. NUMBER
FIRST HOUR
RATING
G.P.H.
RECOVERY
IN G.P.H.
90' F RISE
TANK
HEIGHT
A
HEIGHT TO
WATER CONN.
a
DIAMETER
C
APPROX.
SHIP Wr.
(LBS)
ENERGY
FACTOR
Tall 30
PROE30 T2 RH95r
48
21
47-1/2
50-3/8
19-1/4
92
0.95
Tall 40
PROE40 T2 RH951
57
21
60-3/4
63-5/8
19-1/4
109
0.95
Tall 50
PROE50 T2 RH95'
67
21
58-5/8
61-5/8
20-1/4
121
0.95
Tall 55
PROE55 T2 RH941
71
21
57
59-3/4
22-1/4
128
0.94
Med. 30
PROE30 M2 RH951
44
21
37-1/2
40-1/2
20-1/4
92
0.95
Med. 40
PROE40 M2 RH95?
55
21
48-1/4
50-1/2
20-1/4
106
0.95
Med. 50
PROE50 M2 RH951
65
21
48
50-1/2
23
132
0.95
Short 19.9 PROE20 S2 RH
-
21
31-1/2
31-1/2
17
62
-
Short28
PROE28 S2 RH95
42
21
30
31-1/8
23
95
0.95
Short 30
PROE30 S2 RH95 B"
42
21
30-1/8
32
19-3/4
95
0.95
Short 36
PROE36 S2 RH95
45
21
31-1/2
33
24-1/4
118
0.95
Short 38
PROE38 S2 RH95 B"
55
21
31-1/2
32-5/8
23
108
0.95
Short 47
PROE47 S2 RH95 8"
55
21
32
34
26-1/4
149
0.95
Energy Factor based on D.O.E. (Department of Energy) test procedures.
t System Sentinel optional. Add EC1 to the end of the model number. System Sentinel not available on single
element models, available on dual element models only. System Sentinel not available In excess of 5 kW on
208 V models.
Water heater dimensions prior to installing insulation blanket that is included with water heater.
• Heaters furnished with standard 240 volt AC, single phase non -simultaneous widrly, and 4500 watt upper and lower heating
elements.
• If heating elements of different wattages than those shown are demanded by zone requirements, they must be
specifically requested.
• Single element models available on special order (6000W max.). Substitute "1" for "2" in model number.
• Special Wiring Options - A limited number of special wiring options are available. Consult factory for price and availability.
•
AN models equipped with heat traps.
Recovery = wattage/2.42 x temp. rise °F.
Example: 450OW = 21 GPH
2.42 x 90°
Recovery calculations used are based on 4500 watt elements used in non -simultaneous operation.
Bit
HOT
WATER COLD
CONNECTION WATER
RELIEF VALVECONNECTION
CONNECTION I� eNnno
ROD
DIAMCETER
A
B
WATER CONNECTIONS ALL 314" N.P.T.
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Water Heating • 101 Bell Road
Montgomery, Alabama 36117-4305 it www.rheam.com
PRINTED IN U.S.A. 09/15 WP FORM NO. PROE RH N Rev. 2
Z 'god N Ha 3OUd 'ON VIUOj dM 9t/60 'V'8'n N1 O31NI1ld
wo3'waa41•MMM . 90£b=L L L9£ ewegelV '/(aawoBjuayy
PBOH IlaB LO L • Bullea}I laleM waaya
aogou lnotlpM se6uego wiew of jg6u aqj saluasai waaq f 'luawanoadwl )onpold pue ssaa6ojd snonuquoo Io A:Ztlod sp qj!m 6urdaa)l ul
'1'd'N ,V/£ 11V SNOLL33NNOO a31VM
60t
4/l -9Z
8
Z£
LZ
99
..9 96HU ZS L030ad
Lb i+04S
96'0
a313wv1a
(IOU
8/9-ZE
3OONV E
N01103NNOO
NOLL33NNOO 3A1VA :13113a
»31VM
N01133NNOD
4103 p
U31vM
0/l -OZ
lOH
8
tZ
ualmdo snoaue4nuns•uou a pass sluau>ap liem 0090 w paseq air pasn sualeln0leo
Q06 X Ztp'Z
HdO lZ = M009tr .01dwex3
j, asp 'dwat X Zy'Z/a6vuem = Ajawo%
'sdeil lea4 Mum padonba slapow OV .
AuFgei1e.T pue a0!xi X01 iGotae111►nuo'J 'algepene aye sualdo 6u!1!m lE!0ads 10 Mumu palw!l V - suald0 6uuM le! adS •
-ogwnu lopow u! .Z. jo1.I I. olnl!lsgnS •('xew M0009) japio le!oods uo olge!!ene slapow tuawala al6uS .
•polsanbal Algallloeds
aq lsnw A"Isluawaslnbel auoz rtq popuaWop els umo4s as044 u844 sa8ellBM lualaglp 10 sluautala 6ullea4 p .
sluawala
6ullea4 Jamol pue Jaddn item 009b pile '6umm Snoauellnwis-uou mod al6uis '0V lloA OOZ lnepuets 4Um pa4s!um1 sJaleaH .
'>alea4 lalem 41!m Pamou! S! le4l la)luLA uo!lelnsu! 6u!lletsto of loud suasuomp lalea4 Malum..
siepDW A 80
uo Mil 9;o ssane ul algBlIBAg;ou loulluaS ulolsAS Auo slapow 4uawala lenp uo alggllaAa 'slapow luawale
918uls uo olgellaAe lou loullUeS welsAS aagwnu lapow etp to pue ota of L33 ppV 'lewildo loullueS wats/(S I
'sampa0oJd lsal p(6iau310lu3114Jeda0 •3'0'O uo POseq 1010ej A61au3
96'0
60t
4/l -9Z
0£
Z£
LZ
99
..9 96HU ZS L030ad
Lb i+04S
96'0
80t
£Z
8/9-ZE
Z/l-tE
LZ
99
..8 96HU ZS BE30Hd
8£ IXo4S
96'0
9tt
0/l -OZ
s£
Z/1 -LE
tZ
90
96HU ZS 9E30ad
9E Po4S
96'0
96
0/£-6l
Z£
8/l-0£
LZ
ZO
..9 96H1i ZS OE30ldd
OE v04S
96'0
96
EZ
BA -t£
o£
tZ
Z4
96HU ZS 9Z3OHd
Be Uo4S
-
Z9
Lt
ZA-l£
Z/Vt£
tZ
-
HU ZS OZ3OUd 6'6l VO4S
96'0
act
EZ
Z/1-09
90
LZ
99
,96Hli ZW 0930kld
09 'POW
96'0
90t
VA -0Z
Z/L-09
0/1-80
LZ
99
i96HH ZW 003o1ld
00 'PaW
960
Z6
VA -0Z
Z/Vot?
Z/l-LE
t
00
i96HU ZW OE301ld
0£ 'P8W
06'0
get
0/l -ZZ
0/E-69
L9
I
LG
tt,6HUZ19930ad
99 HUI
96'0
Let
0/L -OZ
8/9-19
8/9 -OS
t
L9
66Ht1Z1093OUd
09 Ogi
96'0
60L
0/l -6L
BMr-£9
0/£-09
LZ
L9
a96HtlZ10030ad
00 Ilul
96'0
Z6
0/t -6t
9/c -Os
Z/l-LO
t
BO
i%HaZ10£30Hd
0£ IIEl
aolovs
ADN3N3
(SOV
1M dIHS
-XOUddV
a
U31 VMO
e
'NNOO a31Vm
O11HDGH
v
1HOSH
XNV1
asla d .116
'Hd'D NI
AH3AO03B
Han
ONLLVH
NnOH to
a38Y1nN dwo 3dA1
1300Y1 1ti0
VANI ASH3N3
(S3H3Nl NI NMOHS) SNOISN3WIa NI IJN1Honou
S3H LLV3d
NOLLd1t10S3a
suoi}eogmads W1gisse/o 1euoissaPad
.:1joluwo to wAk)p a au o41 _.....
S181e0H J818MWSS010 IeuOlssaaOJd
1aleM
31/10813 lei
luaplsaa
C � 1N
Michelle Franklin, CFA -- Saint Lucie County Property Appraiser -- All rights reserved.
Site Address:
parcel ID:
Account #:
Map 1D:
Use Type:
Zoning:
City/County:
Ownership
Maryann Marshall (TR)
Martin R Marah:ill (TR)
8104 Alister PI
Pon St Lucic. FL 34986
Legal Description
POD 26 AT THE RESERVE PHASE. I CYPRESS POINT LOT 26 (OR 3496416)
Current Values
Just/Markel Value:
Assessed Value:
Exemptions:
Taxable Value:
Taxes for this parcel: SLC Tar Collector's ORice 12
Download TRIM for this parcel: Download PDF O
Total Areas
Finished/Under Air (SF): 3,528
Gross Area (SF): 5.726
Land Size (acres): 0.36
Land Size (SF): 15,774
Property identification
8104 Alisecr PL
3327 -707 -W30 -OW -2
139797
33/27N
0100
PUD
Saint Lucie County
This information is believed to be correct at this time but it is subject to change and is not warranted.