HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 4
Business & Professional Regulation
Fla
SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats S Facts Publications FBC Staff SCIS Site Map Links Search
eatrovILE COPY
5 5 '--
USER: L L5
QrodUd Aooroval Menu>Product or Application Search>Application List>Application Detail
FL# FL17499-R2
Application Type Revision
Code Version 2017 mfr
Application Status Approved
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments RECEIVED
Archived ❑
Product Manufacturer MI Windows and Doors JAN 2 9 2018
Address/Phone/Email 650 West Market Street
Gratz,PA 17030 ST. Lucie Count P
(717)365-3300 Ext 2560 y, ermitting
bsitlinger@miwd.com
Authorized Signature Brent Sitlinger
bsitlinger@miwd.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Windows
Subcategory Single Hung
Compliance Method Certification Mark or Listing
Certification Agency American Architectural Manufacturers Association
Validated By Steven M. Unch,PE
Validation Checklist-Hardcopy Received
Referenced Standard and Year(of Standard) Standard Year
AAMA 506 2011
AAMA/WDMA/CSA 101/I.S.2/A440 2008
Equivalence of Product Standards
Certified By
Product Approval Method Method 1 Option A
Date Submitted 12/13/2017
Date Validated 12/29/2017
Date Pending FBC Approval
Date Approved 01/08/2018
http://floridabuilding.org/pr/pr_app_dtl.aspx?paramwGEVXQwtDgtCUGgvj Qiz6BPhSO... 1/19/2018
Florida Building Code Online Page 2 of 4
Date Revised 01/15/2018
Summary of Products
FL# Model,Number or Name Description
17499.1 185 SH 52x72 Fin/Flange Frame IG/SG Impact Single Hung
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:No FL17499 R2 C CAC MI Windows- 185 SH(Fin)Impact
Approved for use outside HVHZ:Yes (2).Ddf
Impact Resistant:Yes FL17499 R2 C CAC MI Windows- 185 SH(Fin)Impact
Design Pressure:+55/-55 (3).pdf
p i Other: R-PG55,Missile Level D,Wind Zone 3.Glass to be FL17499 R2 C CAC MI Windows- 185 SH(Flanoe)Impact
<�A{►C�� bedded in Pecora 896 sealant. (2).odf
FL17499 R2 C CAC MI Windows- 185 SH(Flange)Impact
Quali y Assurance Contract Expiration Date
10/10/2018
Installation Instructions
FL17499 R2 II 08-02544B-1-odf
Verified By: Luis R Lomas PE 62514
Created by Independent Third Party:Yes
Evaluation Reports
FL17499 R2 AE 5133208-1 pdf
Created by Independent Third Party:Yes
17a99.7 1185 SH 52x84 Fin/Flange Frame IG/SG Single Hung
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL17499 R2 C CAC APC(13362)E1725 01 109-47-RO 185
j Approved for use outside HVHZ:Yes SH(FLG waiver)5-8IG 1-8A 52 1-8X84 R60(100918).Ddf
Impact Resistant: No FL17499 7499 R2 C CAC MI Windows- 185 SH(Fin)(10).pdf
Design Pressure: 60/-60 FL17499 R2 C CAC MI Windows- 185 SH(Fin)(9).Ddf
Other: R PG60 FL17499 R2 C CAC MI Windows- 185 SH(Flange)(9)pdf
Quality Assurance Contract Expiration Date
Z 10/09/2018
Installation Instructions
F117499 R2 II 08-025468-2.odf
Verified By:Luis R Lomas PE 62514
Created by Independent Third Party:Yes
Evaluation Reports
FL17499 R2 AE 5133228-2.Ddf
Created by Independent Third Party:Yes
17499.3 18S SH 36x84 Fn/Flange Frame IG/SG Impact Single Hung
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:No FL17499 R2 C CAC MI Windows- 185 SH(Fin)Impact
Approved for use outside HVHZ:Yes (4).Ddf
Impact Resistant:Yes FL17499 R2 C CAC MI Windows- 185 SH(Fin)Impact(5)
Design Pressure: +55/-55 Done.pdf
Other:R-PG55`,Missile Level D,Wind Zone 3.Glass to be FL17499 R2 C CAC MI Windows- 185 SH(Flanoe)Impact
bedded in Pecora 896 sealant. (3).Ddf
FI 17a99 R2 C CAC MI Windows- 185 SH(Flange)Impact
(4).Ddf
Quality Assurance Contract Expiration Date
10/17/2018
Installation Instructions
FL17499 R2 II 08-025456.pdf
Verified By:Luis R Lomas PE-62514
Created by Independent Third Party:Yes
Evaluation Reports
FL17499 R2 AE 5133218-3 pdf
Created by Independent Third Party:Yes
17499.4 185 SH 52x72 Fin/Flange Frame IG/SG Single Hung Laminated Glass
Limit of Use certwication Agency Certificate
Approved for use in HVHZ:No FL17499 R2 C CAC APC(13361)E1726 01-109-47-RO 185
Approved for use outside HVHZ:Yes SH(FLG waiver).vdf
Impact Resistant: No FL17499 R2 C CAC MI Windows- 185 SH(Fin)(11)pdf
Design Pressure: +60/-60 FL17499 R2 C CAC MI Windows- 185 SH(Fin)(12)pdf
Other:R PG60 FL17499 R2 C_CAC_Ki Windows 185 SH(Flanoe)
(10).odf
Quality Assurance Contract Expiration Date
10/08/2018
Installation Instructions
F117499 R2 II 08-02549B,odf
Verified By: Luis R Lomas PE-62514
Created by Independent Third Party:Yes
Evaluation Reports
FL17499 R2 AE 513327B-4.pdf
Created by Independent Third Party:Yes
http://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtCUGgvjQiz6BPhSO... 1/19/2018
Florida Building Code Online Page 3 of 4
17499.5 1185 SH 36x84 Fin/Flange Frame IG/SG Single Hung Laminated Glass
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:No FL17499 R2 C CAC APC(13363)E1729.01-109-47-RO 185
Approved for use outside HVHZ:Yes SH(FLG waiver).pdf
Impact Resistant: No FL17499 R2 C CAC MI Windows- 185 SH(Fin)(13).pdf
Design Pressure:+60/-60 FL17499 R2 C CAC MI Windows- 185 SH(Fin)(14).odf
Other:R-PG60* FL17499 R2 C CAC MI Windows- 185 SH(Flange)
(11).Ddf
Quality Assurance Contract Expiration Date
10/17/2018
Installation Instructions
FL17499 R2 II 08-02550B.odf
Verified By: Luis R Lomas PE-62514
Created by Independent Third Party:Yes
Evaluation Reports
FL17499 R2 AE 513328B-5.pdf
Created by Independent Third Party:Yes
17499.6 185 Triple SH 111x72 Fin Frame IG/SG Single Hung 110x72 Flange Frame
IG/SG Single Hung
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:No FL17499 R2 C CAC_MI Windows- 185 SH Triple(Fin)
Approved for use outside HVHZ:Yes (3).odf
Impact Resistant: No FL17499 R2 C CAC MI Windows- 185 SH Triple(Fin)
Design Pressure: 5C/-50 (4).Ddr
Other:R-K,50' FL17499 R2 C CAC MI Windows- 185 SH Triple(Flange)
(3).Ddf
FL17499 R2 C CAC MI Windows- 185 SH Triple(Flange)
(4).Ddf
Quality Assurance Contract Expiration Date
10/20/2018
Installation Instructions
FL17499 R2 II 08-02548B.Ddf
Verified By: Luis R Lomas PE 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL17499 R2 AE 5133248-6.odf
Created by Independent Third Party:Yes
17499.7 185 Twin SH 106x72 Fin Frame IG/SG Single Hung 105x72 Flange Frame
IG/SG Single Hung
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL17499 R2 C CAC MI Windows- 185 SH Twin(Fin)
Approved for use outside HVHZ:Yes (3).Ddf
Impact Resistant: No FL17499 R2 C CAC MI Windows- 185 SH Twin(Fin)
Design Pressure: •45/-45 (4),Ddf
Other: R-PG45 FL17499 R2 C CAC MI Windows- 185 SH Twin(Flange)
(3),Ddf
FL17499 R2 C CAC MI Windows- 185 SH Twin(Flange)
(4).odf
Quality Assurance Contract Expiration Date
10/20/2018
Installation Instructions
FL17499 R2 II 08-025478-7.Ddf
Verified By:Luis R Lomas PE-62514
Created by Independent Third Party:Yes
Evaluation Reports
FL17499 R2 AE 5133238-7.Ddf
Created by Independent Third Party:Yes
Back Neat
Contact Us::2601 81a'r Sty e Road.Tallah«ee FL 32399 M2ne 850-48T1824
The State of Florida is an AA/EEO employer.Coovnoht 2007-2013 State of Florida ::Privacy Statement::Accewbility Statement::Refund Statement
under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by tradrWrial mail.If you have any questions,please contact 850.487.1395.•Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The em lils provided may be used for official communication with the licence.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please dick here.
ProMrct Approval Accepts:
,it
Credit Card
Safe
http://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtCUGgvjQiz6BPhS0... 1/19/2018
Ar
REVISIONS
REV DESCRIPTION DATE APPROVED
A REVISED ANCHOR SPACING do CHARTS 07/11/16 R.I.
B REVISED GLAZING 09/29/17 R.L.
NOTES: 15.FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE ((10 WOOD
i. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO
REQUIREMENTS OF THE FLORIDA BUILDING CODE. SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY 16. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH
TRANSFER ALL LOADS TO STRUCTURE, FRAMING AND MASONRY OPENING IS THE
RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2
3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN N ELEVATIONS AND
4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE INSTALLATION DETAILS.
ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED 17. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF
INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND
MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION
5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY DETAILS.
18. ALL FASTENERS TO BE CORROSION RESISTANT.
FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY
19. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR
BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN
MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42
COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI.
THE ARCHITECT OR ENGINEER OF RECORD. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PSI MINIMUM.
7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSI OR
PROVIDED, ALUMINUM 6063-T5 FU=30KSI .048" THICK MINIMUM
S. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT
EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR
GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4".
9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE
OF SUSTAINING APPLICABLE LOADS.
10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS.
11. FRAME MATERIAL: EXTRUDED RIGID PVC.
12, UNITS MUST BE GLAZED PER ASTM E1300-04/09, SEE SHEET 9 FOR GLASS DETAILS.
13, APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND
BORNE DEBRIS REGIONS.
14. FOR ANCHORING THROUGH FIN INTO WOOD FRAMING OR 2X BUCK USE MB WOOD SCREWS
WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE.
LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
SIGNED: 10/02/2017
MI WINDOWS AND DOORS, LLC ��u►1llurrrri
650 WEST MARKET STREET �X\\J\`' �D�q/ice
GRATZ, PA 17030-0370 ���•��GENS� ,�P
SERIES 185 ALUMINUM SINGLE HUNG WINDOW =*• 0 l''51 *=
52"x72" IMPACT =o
TABLE OF CONTENTS NOTES ��0, TATE OF
SHEET NO. DESCRIPTION P �
DRAWN: 0'WG N0. REV ///�S��DRL�•G\\\\
1 NOTES scAiE DATE OB s�EEr44 B �ii7S�ONAj1E�
2 - 3 ELEVATIONS NTS 12/09/14 1 OF 9 flim
5 - 8 INSTALLATION DETAILS L.ROBERTO LOMAS P E Luis R. Lomas P.E.
1432 WOODFORD RD LEWISVRIE,NO 17023 FL No.: 62514
9 COMPONENTS k GLASS DETAILS 434-888-0609 60-15@10—SPO—m
REVISIONS
REV OMRFTION QVE IPRROVEO
52" MAX FRAME WIDTH 52" MAX FRAME WIDTH
A REVISED ANCHOR SPACING & CHARTS 07/11/16 R.L.
2" MAX I 16" MAX O.C. 2" MAX 2" MAX 16" MAX O.C. --{ 2" MAX B REVISED GLAZING 09/29/17 R.L.
/Tal-
2'- CHART#1
Number of anchor locationsd
2 (in)
LLL / Frame F
me Wfdth In
Height 18.00 24.00 30.00 36.00 1 42.00 48.00 52.00
16" O (int Head Jamb Head Jamb Head Jamb Head Jamb Head Jamb Head Jamb Head Jamb
MAX MAX / 24.00 2 3 3 3 3 3 3 3 4 3 4 3 4 3
O.C. f O.C. 30.00 2 3 3 3 3 3 3 3 4 3 4 3 4 3
72" T— / 72" 36.00 2 3 3 3 3 3 3 3 4 3 4 3 4 3
MAX MAX -- 42.00 2 4 3 4 3 4 3 4 4 4 4 4 4 4
48.00 2 4 3 4 3 4 3 4 4 4 4 4 4 4 1
FRAME FRAME 54.00 2 5 3 5 3 5 3 5 4 5 4 5 4 5
HEIGHT /\ HEIGHT 60,00 2 5 3 5 3 5 3 5 4 5 4 5 4 5
/ \ 66.00 2 5 3 5 3 5 3 5 4 5 4 5 4 5
"�ILJI� ,ILJIr 72.00 2 6 3 6 3 8 3 5 4 5 4 6 1 4 6
185 ALUMINUM SINGLE HUNG WINDOW 185 ALUMINUM SINGLE HUNG WINDOW
EXTERIOR VIEW DESIGNER EXTERIOR VIEW
FLANGE 8 FINLESS INSTALLATION FLANGE 8 FINLESS INSTALLATION
SEE CHART#1 FOR SMALLER UNITS REQUIRED ANCHORS SEE CHART M1 FOR SMALLER UNITS REQUIRED ANCHORS
DESIGN PRESSURE HATING IMPACT RATING
t55.OPSF LARGE
MISSILE IMPACT
MISSILE LEVEL D,WIND ZONE 3
SIGNED: 10/02/2017
NOTES: MI 650 WEST T MA D MARKET
ET LLC \\\\\\51IR 111 I ILI0 ��///
1. MAXIMUM SASH SIZE: 51" X 36". GRATZ, PA 17030-0370 •�\GENSF9J'��
2. MAXIMUM SASH D.L.O.: 47 5/8" X 32 1/2".
3. MAXIMUM FIXED D.L.O.: 49 3/8" X 32 1/2". SERIES 185 ALUMINUM SINGLE HUNG WINDOW =*• 10,8¢61 #
52"x72" IMPACT
FLANGE & FINLESS ELEVATIONS TATE OF t411
DRAWN: DWG N0. REV
—0 to G\ \�
N.G. 08—C2544 B //JS/ONA/111 11��
HARDWARE SCHEDUALE LE NTS DAiE 12/09/14 2 OF 9
r (2)METAL SWEEP LOCK AT FROM EACH END INTERIOR MEETING RAIL L.ROBERTO LOMAS P.E. Luis R. Lomas P.E.
. 1432 WOOOFORD RD LEWISVILLE.MC 27023 FL No.: 62514
. (2)BLOCK AND TACKLE BALANCE AT JAMBS
434-688-0609 rNomea®hbmeape.com
REVISIONS
52" MAX FRAME WIDTH I^ 52" MAX FRAME WIDTH Rev oescRwnON DATE �rpaaaEo
A REVISED ANCHOR SPACING & CHARTS 07/11/16 R.L.
2" MAX (— 10 2" MAX 2" MAX �— �{ 0"
MAX O.C. f MAX O.C. 2 MAX 8 REVISED CLALNG 09/29/17 R,L,
CHART#2
TT- --
-L_ �— Number of anchor locatlons required
/ 10" MAX O , Frame Frame Width In
/ O.C. / Height 18.00 24.00 30.00 1 3&00 4200 48.00 5200
772• / 4 0 H B S Jamb HBS Jamb H 8 S Jamb H B S Jamb H B S Jamb H S S Jamb H 8 5 Jamb
MMAX _ 24.00 3 3 3 3 4 3 5 3 5 3 6 3 6 3
FRFRAME 3000 3434 4 4 5 a 5 a e 4 6 4
HEIHEIGHT 36.00 3 5 3 5 4 5 5 5 5 5 6 5 6 5
42.00 3 5 35 4 5 5 S 5 5 8 5 848.00 3 8 3 8 4 6 5 6 5 8 6 6654.00 3 6 3 6 4 6 5 6 5 5 6 6 6 6
37 3 7 4 7 5 7 5 7 6 7 8 3 8 3 8 4 8 5 8 5 8 8 8 6
72.00 13 1 8 1 3 1 8 4 1 8 5 8 8 6 8 6 8
L4
185 ALUMINUM SINGLE HUNG WINDOW 185 ALUMINUM SINGLE HUNG WINDOW
EXTERIOR VIEW DESIGNER EXTERIOR VIEW
FIN INSTALLATION RN INSTALLATION
SEE CHART#2 FOR SMALLER UNITS REQUIRED ANCHORS SEE CHART#2 FOR SMALLER UNITS REQUIRED ANCHORS
DESIGN PRESSURE RATING IMPACT RATING
t55.OPSF LARGE
MISSILE IMPACT
MISSILE LEVEL D,WINO ZONE
SIGNED:10/02/2017
NOTES: MI WINDOWS AND DOORS, LLC ��u111ilIll���
1. MAXIMUM SASH SIZE: 51" X 36". 650 WEST MARKET STREET J���S R. Lp�/i��
2. MAXIMUM SASH D.L.O.: 47 5/8" X 32 1/2". GRATZ, PA 17030-0370 `��� J
.'rEN "9i��
3. MAXIMUM FIXED D.L.O.: 49 3/8" X 32 1/2". SERIES 185 ALUMINUM SINGLE HUNG WINDOW _*• 06251
x7 *=
52" 2" IMPACT
FIN ELEVATIONS r o• TATE O0.
F
DRAWN: DWG N0. �•
N.G. 08-02544 R ��iFSS�OR10P•G�f\��
HARDWARE SCHEDULE SALE NTS DArE 12/09/14 CD3 OF 9
(2)METAL SWEEP LOCK AT 8"FROM EACH END INTERIOR MEETING RAIL L.ROBERTO COMAS P.E.
(2)BLOCK AND TACKLE BALANCE AT JAN BS 1432 WOODFORD RD LEWISVILLE,NC 27023 Luis R. Lomas P.E.
434-686-060.9 Nbmas®6brraspecom FL No.: 62514
f'
I
1/2" MIN REVISIONS
EDGE DISTANCE 1/2" MIN Rev DESCRIPTION DATEvvRGvm
WOOD FRAMING METAL EDGE DISTANCE
OR 2X BUCK STRUCTURE A REVISED ANCHOR SPACING dt CHARTS 07/11/16 R,L.
BY OTHERS BY OTHERS 1/4" MAX. B REVISED GLAZING 09/29/17 R.L.
1 1/4" MIN. SHIM SPACE
EMBEDMENT _ 1 1/4" MIN. 1/4" MAX.
I 'r EMBEDMENT SHIM SPACE
BACKER ROD APPROVED T �_
& APPROVED 1/4" MAX. SEALANT
SEALANT SHIM SPACE 1/2
MIN
EDGE INTERIOR
DISTANCE
x/10 WOOD SCREW #10 SMS OR
SELF DRILLING
SCREW N10 WOOD
lNTERlOA
INTERIOR SCREW
WOOD FRAMING EXTERIOR
OR 2X BUCK BACKER ROD
BY OTHERS & APPROVED
SEALANT
JAMB INSTALLATION DETAIL
WOOD FRAMING OR2X BUCK INSTALLATION
1/4" MAX.
SHIM SPACE
EXTERIOR EXTERIOR
1y10 SMS OR
SELF DRILLING INTERIOR
SCREWS
SILL TO BE SET 1 2
SILL TO BE SET IN A BED OF MIN.
IN A BED OF APPROVED EDGE
APPROVED STRUCTURAL DISTANCE
STRUCTURAL BACKER ROD SEALANT -1—
BACKER ROD SEALANT & APPROVED I EXTERIOR
& APPROVED SEALANT 1/4" MAX. METAL
SEALANT 1/4" MAX. SHIM SPACE STRUCTURE BACKER ROD
r SHIM SPACE METAL BY OTHERS & APPROVED
EALAINSTAL
WOOD FRAMING STRUCTURE
OR 2X BUCK BY OTHERS JAMB INSTALLATION DETAIL
BY OTHERS METAL STRUCTUREINSTALLATION SIGNED: 10/02/2017
VERTICAL CROSS SECTION MI WINDOWS AND DOORS, LLC ����►11iIr11/�
METAL STRUCTURE INSTALLATION 650 WEST MARKET STREET \\\��5 R•Lp�/,,
VERTICAL CROSS SECTION GRATZ, PA 17030-0370 `�r.�\p EN,S�.q�I�i�
WOOD FRAMING OR 2X BUCK INS TALLATION SERIES 185 ALUMINUM SINGLE HUNG WINDOW *• p,�g�$ *=
52"x72" IMPACT — e0 =
FLANGE INSTALLATION DETAILS TATE OF
NOTES: DRAWN: DWG NO. aev �i ••�� -Z
08-02544
I.INTERIOR AND EXTERIOR FINISHES,BY OTHERS, OR1�. \\
NOT SHOWN FOR CLARITY. N.G. OB-02544 B /sS G\\
2.PERIMETER AND JOINT SEALANT BY OTHERS TO BE scxe NTS D^� 12/09/14 s"E�4 OF 9 /",-S"o�AL1�a�\\
DESIGNED IN ACCORDANCE WITH ASTM E2112
L.ROSERTO LOMAS PE. LUIS R. Lomas P.E.
1432 WOODFORD RD LEWISVILLE,NC 27323 FL No.: 62514
434{{83.0609 ,lfome9N11rlorn 6pe.mm
2 1/2" MIN. _ REhsoes
EDGE DISTANCE REV DESCRIPTION DATE MFROVFD
CONCRETE/MASONRY A REVISED ANCFi7R SPACING h CHARTS 07/11/16 R.L.
BY OTHERS •• e • . B REVISED GLAZNG 09/29/17 R.L.
e
• sc
OPTIONAL 1X BUCK . ° 1 1/4" MIN.
SEE NOTES 3 - 7 EMBEDMENT 1 1/4" MIN. 1/4" MAX,
SHEET 1 -� EMBEDMENT I SHIM SPACE
I CONCRETE/MASONRY
1/4" MAX. j BY OTHERS
BACKER ROD SHIM SPACE
& APPROVED °
SEALANT
3/16" TAPCON 3/16" TAPCON ' •° '
INTERIOR '• ° INTERIOR
2 1/2" ..
MIN.
EDGE v '
EXTERIOR DISTANCE
E EXTERIOR
1- BACKER ROD
& APPROVED
OPTIONAL 1X BUCK SEALANT
SEE NOTES 3 - 7
SHEET 1 JAMB INSTALLATION DETAIL
CONCRETEIMASONRY INSTALLATION
SILL TO BE SET
IN A BED OF
BACKER ROD APPROVED NOTES:
& APPROVED STRUCTURAL 1.INTERIOR AND EXTERIOR FINISHES,BY OTHERS,
SEALANT SEALANT NOT SHOWN FOR CLARITY.
2.PERIMETER AND JOINT SEALANT BY OTHERS TO BE
OPTIONAL 1X BUCK 1/4" MAX. DESIGNED IN ACCORDANCE WITH ASTM E2112 SIGNED: 10/02/2017
SEE NOTE 3 - 7 `SHIM SPACE
SHEET 1 MI WINDOWS AND DOORS, LLC \\1�1111111/1I7,,
650 WEST MARKET STREET
J�S FZ LO�q�ii
CONCRETE/MASONRYA GRATZ, PA 17030-0370 •��GENS*.•,�
BY OTHERS °
° SERIES 185 ALUMINUM SINGLE HUNG WINDOW =*• o,81261 k=
+' • 52x72" IMPACT - /mac�
°•, ' y a f !'� FLANGE INSTALLATION DETAILS �y°DTATE OF
e
° �.o'
DRAWN:
VERTICAL CROSS SECTION srxc wre I.
08 502544 js�ONAL1Ea��`�
NTS 12/09/14 5 OF 9
CONCRETFIMASONRY INSTALLATION
L.ROBEATO LOMAS PE. LU15 R. Lomas P.E.
1432 WOODFORD RD LEWISVILlE,NC 27023 FL No.: 62514
434-6880609 100-S@100-SP-
illy
('ETA
" 1/2" MIN REV6IONS
rEDGE DISTANCE wTE --PROVED
I RE DESCRIPTION
METAL A REVISED ANCHOR SPACING & CHARTS 07/11/16 R.L.
WOOD FRAMING STRUCTURE
OR 2X BUCK BY OTHERS 1/4'" MAX. B REVISED GLAZING 09/29/17 R.A.
BY OTHERS SHIM SPACE _
1 1/4" MIN. 1/4" MAX.
EMBEDMENT SHIM SPACE
BACKER ROD APPROVED — —
& APPROVED SEALANT
SEALANT 1/2
MIN
EDGE INTERIOR
DISTANCE
#1WOOD SCREW
INTERIOR #10 SMS OR #10 WOOD
INTERIOR SELF DRILLING SCREW ��
SCREW
WOOD FRAMING EXTERIOR
OR 2X BUCK BACKER ROD
BY OTHERS
& APPROVED
SEALANT
JAMB INSTALLATION DETAIL
WOOD FRAMING OR 2X BUCK INSTALLATION
EXTERIOR
EXTERIOR t IM MAX.
SHIM SPACE
#10 SMS OR
SELF DRILLING INTERIOR
SCREWS l
l — -
SILL TO BE SET 1/2"
SILL TO BE SET IN A BED OF MIN.
IN A BED OF APPROVED EDGE DO
APPROVED STRUCTURAL DISTANCE
STRUCTURAL BACKER ROD SEALANT 1 EXTERIOR
BACKER ROD SEALANT & APPROVED
& APPROVED SEALANT BACKER ROD
SEALANT _ 1/4" MAX. --1 1/4" MAX. METAL & APPROVED
F SHIM SPACE SHIM SPACE STRUCTURE SEALANT
--- BY OTHERS JAMB INSTALLATION DETAIL
WOOD FRAMING METAL METAL STRUCTURE INSTALLATION SIGNED: 10/02/2017
OR 2X BUCK STRUCTURE
BY OTHERS BY OTHERS MI WINDOWS AND DOORS, LLC ���11111111/I//
650 WEST MARKET STREET \\\\J�5 R• L
GRATZ. PA 17030-0370 `r .*,O,EN,�psi
VERTICAL CROSS SECTION VERTICAL CROSS SECTION SERIES 185 ALUMINUM SINGLE HUNG WINDOW =*• 0 61 *=
WOOD FRAMING OR 2X BUCK INSTALLATION METAL STRUCTURE INSTALLATION 52'X72" IMPACT
FINLESS INSTALLATION DETAILS ,?1 STAT OF
NOTES: DRAWN. owe No. Rey iO''••'Cl P. ��
1,INTERIOR AND EXTERIOR FINISHES,BY OTHERS, i F ••DRIO, \ '
NOTSNOWNFORCLARITY. N.G. 08-02544 B sS G\\
2.PERIMETER AND JOINT SEALANT BY OTHERS TO BENTS DATE 12/09/14 seLET6 OF g �NAL1E���\
DESIGNED IN ACCORDANCE WITH ASTM E2112
1..ROBERTOLOMASPE Lu15 R. Lomas P.E.
1432 WOODFORD RD LEWISVILLE,NG 27023
434-688-0609 Alomas@lAom pe.rom FL No.: 62514
RENSN)NS
2 1/2" MIN. REV DESCRIPTION D•TE I APPROVED
EDGE DISTANCE A REVISED ANCHOR SPACING & CHARTS 07/11/16 R.L.
CONCRETE/MASONRY
BY OTHERS B REVISED GLAZING 09/29/17 R.L.
'• e''
a
OPTIONAL 1X BUCK • • •e. •e 1 1/4" MIN. 1 1/4" MIN,
SEE NOTES 3 – 7 EMBEDMENT EMBEDMENT
SHEET 1 CONCRETE/MASONRY
BY OTHERS OPTIONAL IX BUCK
/4" MAX. • SEE NOTES 3 – 7
BACKER ROD SHIM SPACE
,v SHEET 1
& APPROVED •
SEALANT
3/16" TAPCON `°
3/16" TAPCON 1/4" MAX.
•. SHIM SPACE
INTERIOR V INTERIOR
2 1/2" .,
MIN, dq
EDGE
DISTANCE
EXTERIOR •• EXTERIOR
BACKER ROD
do APPROVED
SEALANT
JAMB INSTALLATION DETAIL
SILL TO BE SET CONCRETEIMASONRYINSTALLATION
BACKER ROD IN A BED OF
dL APPROVED APPROVED NOTES:
SEALANT STRUCTURAL 1.INTERIOR AND EXTERIOR FINISHES,BY OTHERS,
AD,— SEALANT NOT SHO WN FOR CLARITY.
OPTIONAL IX BUCK2.PERIMETER AND JOINT SEALANT BY OTHERS TO BE
SEE NOTE 3 – 7 1/4" MAX. DESIGNED IN ACCORDANCE WITHASTM E2112
SHEET 1 r SHIM SPACE SIGNED: 10/02/2017
M
CONCRETE/MASONRY f 650DOE5T MARKETD DOORS, LLC
\�T \\\ S lR 11L107jX////
BY OTHERS • GRAT2, PA 17030-0370 w•'�GENS
• •. SERIES 185 ALUMINUM SINGLE HUNG WINDOW =*' �Y0 61 *=
a ! • ,' 52"x72" IMPACT
n ,. FINLESS INSTALLATION DETAILS ,=
��, TAT, OF ,{Lc,r,�
G DRAWN: DWG N0.
VERTICAL CROSS SECTION SGLE DArE OS SOYE544 e S�ONALIEN��`�
CONCRETE/MASONRYINSTALLATION NTS 12/09/14 7 OF 9
L.ROBERTO LOWS P E.
LUIS R. Lomas P.E.
1432 WOOD FORD ROLEMSVILLE,NC27023 FL ND.: as P
434666-0609 rI?0fM5 1lAwwp•.com
REVISIONS
1 1/4" MIN. REV DESCRIPTION DATE APPROVED
APPROVED 07/1!/16 R.L.
EMBEDMENT
SEALANT A REVISED ANCM7R SPACING d<CHARTS
BEHIND FIN WOOD 8 REVISED GLAZING 09/29/17 R.L.
FRAMING
BY OTHERS
1/4" MAX.
- F SHIM SPACE
7/16" MIN _
EDGE DISTANCE
WOOD FRAMING 1/4" MAX
#B WOOD SCREW BY OTHERS SHIM SPACE
#8 WOOD SCREW
INTERIOR
1 1/4- INTERIOR
MIN.
EMBEDMENT
-T-
I
APPROVED
SEALANT
BEHIND FIN
EXTERIOR
7/16" MIN EXTERIOR
EDGE DISTANCE
JAMB INSTALLATION DETAIL
WOOD FRAMING OR 2X BUCK INSTALLATION
#8 WOOD SCREW
� NOTES:
1.INTERIOR AND EXTERIOR FINISHES,BY OTHERS,
1/4° MAX NOT SHOWN FOR CLARITY.
SHIM SPACE 2.PERIMETER AND JOINT SEALANT BY OTHERS TO BE
DESIGNED IN ACCORDANCE WITH ASTM E2112
SIGNED: 10/02/2017
7/16" MIN ] — MI WINDOWS AND DOORS' LLC ���1111illlri
EDGE DISTANCE ����g
650 WEST MARKET STREET �'A l79
APPROVED WOOD GRATZ, PA 17030-0370 `�r••�VGENS� s
SEALANT I FRAMING SERIES 185 ALUMINUM SINGLE HUNG WINDOW ;4,BEHIND FIN 1 1/4" MIN. BY OTHERS 52"x72" IMPACTEMBEDMENT FIN INSTALLATION DETAILS STATFTICAL ROSTAION SSSEIONNWOOD FRAPN. O -0EV 2544 RB s/pNAi-ENG
sc.aE NTS DATE 12/09/14 S,CET8 OF 9 ,T//111itI1IN\\\
L.ROBERTO LOMAS PE. LUIS R. Lomas P.E.
14J2 WOODFORD RD LEWISVILLE.NC 27023 FL No.: 62514
434 688
0609 rll0m85@lrlonavpe.com
REVISIONS
2 3/16" 1 7/8" Rev ocsADATE APPROVED
2 3/16"� A REVISED SP
ANCROR SPACING k CHARTS 07/11/16 R.L.
8 REVISED GLAZING 09/29,x17 R.L.
3/16" 2 3/16" 1 2 3/16"
L7 1 SI 6" LT--j
FLANGE FRAME HEAD FLANGE FRAME JAMB FINLESS FRAME HEAD5/8"
CM-18501 FINLESS FRAME JAMB
ALUMINUM 6063-T5.050"THICK CM-18503 CM-18553 CM-18513
ALUMINUM 6063-T5.050"THICK ALUMINUM 6063-T5.050"THICK ALUMINUM 6063-T5.050'THICK t/8" ANN. 1/8- ANN.
2 5/16" -j 2 5/16" 12 5/16" -1 1/8" ANN.
.090 PVB BY KURARAY
FMETAL REINFORCED
BUTYL SPACER
-' 2 3/116" '- EXTERIOR
3 3/8" 2 13/1 " 3 3/4" 1 L_ INTERIOR
Ll�
I 1/2" BITE SILICONE
��r 2 5/16"
1� SETTING BLOCK SEALANT
FLANGE FRAME SILL FINLESS FRAME SILL GLAZING DETAIL
CM 18502 CM-18554 FIN FRAME SILL FIN FRAME HEAD
ALUMINUM 6063-75.055'THICK ALUMINUM 6063-T5.055"THICK
CM-18509 CM-16506
ALUMINUM 6063-T5.055"THICK ALUMINUM 6063-T5.050"THICK
1 7/16"
—I 1 5/8" r 1 1/8" 2 3/g,.
2 5/16"
2" 2 3/16.,
J� L
I =�[
LOCK RAIL/STILE SASH BOTTOM RAIL MEETING RAILFIN FRAME JAMB
CM-16505
ALUMINUM 6063-T5.062CM-18555 CM-16504 CM-18510
"THICK ALUMINUM 6063-T5.050"THICK ALUMINUM 6063-T5.055"THICK ALUMINUM 6063-T5.050"THICK
1—� 1/8 —11 3/8 SIGNED: 10/0212017
MI WINDOWS AND DOORS, LLC \\�JlllIC///
/ 650 WEST MARKET STREET "\� �5," .
GRATZ, PA 17030-0370 `��v.'�OENS'9s%
T - T-- F• ,
SERIES 185 ALUMINUM SINGLE HUNG WINDOW =*X 0 61 #-
GLAZING BEAD SASH STILE 52"x72" IMPACT — -
CM-18535 CM-18507 COMPONENTS 0T'AfE OF
RIGID PVC.050"THICK ALUMINUM 6063-T5.050"THICK DRAWN REV
�0�.'FTATro'. \\
OWG N0.
N.G. 08-02544 B FSS,•.."•�G`���
LNTS DATE 12/09/14 siEET9 OF 9 //7T'111111101L ROBERTOLOAWSP..E LUIS R. Lomas P.E.
1192 WOODFORD RD LEWISVILLE,NO 27023
x34688.0609 rllwnes@1rj=85pecom FL No.: 62514