HomeMy WebLinkAboutProduct Approval - - RECEIVED JAN 31 Z01FILE C01- I F7 ST. Lucie County, Permitting WEATHER KING PORTABLE BUILDINGS 760 WESTBROOK ROAD HICKORY, KY 42051 GENERAL NOTES: 1.ANCHORING PLANS ARE TO BE USED IN CONJUNCTION WITH BUILDING PLANS, 8.GROUND ANCHORS DESIGNED FOR SOIL CLASS 4a OR BETTER. SUBMITTED SEPARATELY. SOIL CLASS 4a: CONSISTS OF LOOSE TO MEDIUM DENSE SANDS,FIRM TO STIFF CLAYS AND SILTS,ALLUVIAL FILL. 2.DESIGN LOADS ARE IN ACCORDANCE WITH THE 2017 FLORIDA BUILDING CODE. BLOW COUNT,PER ASTM DI S88,OF 18 TO 23,AND A READING ON A TORQUE PROBE OF 276 TO 360 INCH POUNDS,THE MINIMUM ANCHOR LENGTH FOR SOIL CLASS 4s SHALL BE 48 INCHES. 3.WIND LOADS ARE BASED ON THE FOLLOWING: ULTIMATE DESIGN WIND SPEEDS:2017 FBC FIGURE 1609.3(3) Vult•120 MPH Vull•140 MPH VIIK•160 MP EGH RISK CATEGORY I EXPOSURE CATEGORY C INTERNAL PRESSURE COEFFICIENT: GCPI-t0.18 4.THE MINIMUM ANCHORAGE SHALL BE AN ANCHOR AT EACH CORNER OF THE BUILDING. LOCATE THE ANCHOR WITHIN 12 INCHES FROM THE CORNER.REFER TO ANCHOR SCHEDULE FOR ADDITIONAL ANCHORS THAT MAY BE REQUIRED.ANY ADDITIONAL ANCHORS BETWEEN THE CORNERS SHALL BE SPACED EQUALLY. 5.WEATHER KING IS NOT RESPONSIBLE FOR THE PREPARATION OF THE PROPOSED SITE OR DETERMINATION OF THE SITES SUITABILITY TO SUPPORT THE PROPOSED STRUCTURE.IT IS THE PROPERTY OWNERS RESPONSIBILITY TO DETERMINE IF SITE CONDITIONS ARE SUITABLE TO SUPPORT THE STRUCTURE. 6.TIE-DOWNS AND ANCHORS ARE TO BE SUPPLIED AND INSTALLED BY THE PROPERTY OWNER. WEATHER KING IS NOT RESPONSIBLE FOR ANCHORING THE BUILDING. 7.THE SCHEDULES INDICATE THE RECOMMENDED NUMBER AND TYPE OF BUILDING ANCHORS TO BE INSTALLED By THE PROPERTY OWNER ALONG EACH SIDE OF THE BUILDING.GROUND ANCHORS SHALL BE RATED FOR SOIL CLASSIFICATION 4a.IT IS THE PROPERTY OWNERS RESPONSIBILITY TO VERIFY THE SOIL TYPE FOR THE SITE WHERE THE BUILDING IS TO BE PLACED. MASTER ANCHORING PLANS--FLORIDA--FBC 2017 N10.77209 PROJECT NO: _ * = SHEETNUMBER q• - ♦ DATE: 11-15-2017 p•.• STATE King �yD�M S-0-AP _O_�^ O .� OF P Weather ■ \' ry CN CHECK D KW try �ORIO..• c� ■ • IIS CHECKED BY: KL IN PORTABLE BUILDINGS REwSKx: SCALE:NONE SCHEDULES FOR GROUND ANCHORS W/STRAPS UPLIFT ANCHORAGE SCHEDULE FOR WIND UP TO 120 MPH BLDG NUMBER OF ANCHORS EACH SIDE OF BUILDING WIDTH 10'-0" 17-0' 37 14'40' 18'-0' 18'-0' 20'-0' 27-0' 24'-0' 28'-0' 28'-0' 30'-0' .0' 8'-0' 2 2 3 3 10'-0' 2 22 3 3 3 11'-Y 2 2 J 1 3 3 3 3 3 3 3 4 UPLIFT ANCHORAGE SCHEDULE FOR WIND 121 TO 140 MPH BLDG NUMBER OF ANCHORS EACH SIDE OF BUILDING WIDTH 10'-0' 17-0' 14'-0' 18'-0' 18'-0' 20'4" 22'-0- 24'4' 28'-0- 28'-0' 30'-0' 37-0' 8'-0' 3 3 4 4 101-0' 3 3 3 3 1 4 11'-Y 2 3 3 4 4 4 4 5 5 5 5 UPLIFT ANCHORAGE SCHEDULE FOR WIND 141 TO 160 MPH BLDG NUMBER OF ANCHORS EACH SIDE OF BUILDING WIDTH 10'-0' 17-0' 14'-0' 18'4' 18'-0' 20'-0' 22'-0'124'-V 29-V 1 28'4' 30'-0' 37-0' 4 1 1 5 5 5 5 5 5 8 8 7 7 �I�IIIINN���I E sF - MASTER ANCHORING PLANS--FLORIDA--FBC 2017 •; No.77209 t c * vaaecr ao SHEET NUMBER • STATE DATE: 1115-2017 '•:<OR10.�•• OR-BY; KLN S P W e a t h e r King- CHECKED By-' KLN 8_111 _AP PORTABLE BUILDINGS REVISION: SCALE: n-s•n SCHEDULES FOR EYE ANCHORS BOLTED TO BUILDING UPLIFT ANCHORAGE SCHEDULE FOR WIND UP TO 120 MPH SLOG NUMBER OF ANCHORS EACH SIDE OF BUILDING WIDTH 10'-0'I 17-0' 18'-0' 18'-0' 20'-0'127f 21'-0' 28'-0' 28'-0' 30'-0' 37-0' 8'-0' 23 3 101-W 2 33 3 11'•7 2 3 3 3 3 1 3 I 1 4 t 4 5 UPLIFT ANCHORAGE SCHEDULE FOR WIND 121 TO 140 MPH BLDG NUMBER OF ANCHORS EACH SIDE OF BUILDING WIDTH 10'-0' 17-0' 11'-0' 18'-0' 18'-0' 20'-0' 27-0' 2/'-0' 28'-0' 28'-0' 30'-0' 37-0' 8'-0' 4 4 5 5 10'4' 3 4 ♦ 4 5 1 S 11'-7 3 / 4 5 1 5 1 5 1 S 1 8 1 8 1 7 1 7 UPLIFT ANCHORAGE SCHEDULE FOR WIND 141 TO 160 MPH BLDG NUMBER OF ANCHORS EACH SIDE OF BUILDING WIDTH 10'-0' 17-0' 14--0' 16'-0' 18'-0' 20'-0' 27-0' 24W 28'-0' 28'-0' 30'-0' 37-0' 8'-0' S 5 8 6 10'-0- 4 5 5 5 8 8 11'-2' 4 6 5 6 8 7 7 6 6 6 9 :. JCEN3F MASTER ANCHORING PLANS--FLORIDA--FBC 2017 $t N0.77209 * PROJECT No SHEET VUMPFR STATE DATE: 11-15-2017 '• OF El�m pK ■/yyV■ DRArm ev: ,`^� 1'//J P�ORIOP:•• Lather ■ \Ing(�J CHECKEDBn KLN V-I.Y_A1 1r i. J°'^°"'n-Is•n TABLE BUILDINGS REVISION: SCALE: I PROVIDE 2,TRTD BLOCKING AT BOLT LOCATION.PLACE W/GRAIN RUNNING 20 GA.x 1Y,'WIDE GALVANIZED VERTICALLY.ATTACH TO RIM JOIST STRAP EXTENDED OVER SKIDS. ATTACH ANCHOR TO W/(S)10C NAILS MIN. ATTACH TO ANCHOR W/SLOTTED RIM BOARD W/)5'0 BOLT PER MANUF.SPECS. BOLT W/WASHER (GALV.) N REFER TO SCHEDULE REFER TO SCHEDULE FOR ANCHOR INFO. FOR ANCHOR INFO. FINISH FOR OUTSIDE GRADE GRADE SKID(TYP) 1-BOLTED EYE ANCHOR DETAIL 2-TYPICAL ANCHOR W/STRAP DETAIL OUTSIDE 20 GA x 1Y.'WIDE GALVANIZED SKID(TYP) STRAP EXTENDED OVER SKIDS. ATTACH TO ANCHOR W/SLOTTED RECOMMENDED GROUND BOLT PER MANUF.SPECS. O ANCHOR SCHEDULE w TIECDOWN ONCRA CHOR FINISH O g Y saL O ANCHOR DESCRIPTION REFER TO SCHEDULEGRADE I�u CLASS FOR SPACING(TYP) e j W 0 ROD x 48'LONG w/(1)B'HELD( WO ROD.48'LONG w/(1)8'HELD( 4a 1/i 0 ROD x 48'LONG w/(2)4'HELD( EYE ANCHOR-%'0 ROD x 48'LONG w/(1)8'HELIX /\ EYE ANCHOR-WO ROD x 48'LONG W(1)8'HELIX / NOTE:REFER TO NOTE 8 ON SHEET S-0 FOR SOIL CLASS ATTACH ANCHOR TO \ DESCRIPTION. CONCRETE SLAB ON CONCRETE W/v DUl GRADE BY OTHERS. EXPANSION BOLT W/ -.IN 3'EMBEDMENT(TYP) 3-TYPICAL CONCRETE ANCHOR W/STRAP DETAIL i :0 IIIsF MASTER ANCHORING PLANSFLORIDA--FBC 2017 4`N L. -- •Y.• GEN''•.,y.'"s j• No.77209 '; * I PROJECT NO SHEET NUMBER DATE: $TATE � 11-152017 ~.<OR10P• W KLN e a t h e r King-) DRANK BV:CHECKED BV: KLN S-2.1-AP CCCCCC��f��f�����eeV�1� 1-1 PORTABLE BUILDINGS REVISION: SCALE:1'=1'-0 PROVIDE Zx TRTD BLOCKING AT BOLT LOCATION.PLACE W/GRAIN RUNNING 20 GA.z 1Y.'WIDE GALVANIZED VERTICALLY.ATTACH TO RIM JOIST STRAP EXTENDED OVER SKIDS. ATTACH ANCHOR TO W/(6)10d NAILS MIN. ATTACH TO ANCHOR W/SLOTTED RIM BOARD W/)4'O OUTSIDE BOLT PER MANUF.SPECS. FINISH BOLT W/WASHER SKID(TYP) GRADE (GALV.) FINISH GRADE REFER TO SCHEDULE REFER TO SCHEDULE FOR ANCHOR INFO. FOR ANCHOR INFO. OPTIONAL 18'z18'x1'SOLID MASONRY OPTIONAL 16"x1654"SOLID MASONRY BLOCK PAD.REFER TO SCHEDULE BLOCK PAD.REFER TO SCHEDULE FOR QUANTITY AND SPACING. FOR QUANTITY AND SPACING.(TVP) 1-BOLTED EYE ANCHOR DETAIL W/OPTIONAL BLOCK PAD 2-TYPICAL ANCHOR W/STRAP DETAIL W/OPTIONAL BLOCK PAD I i OPTIONAL BLOCK PAD SCHEDULE BLDG NUMBER OF PADS BENEATH EACH SKID WIDTH 101-0' 17-0' 14'-0' 16'-0' 18'-0' 20'-0' 22'-0' 24'-0' 26'-0' 2B-0' 301-0' 37-M 2 3 3 3 10'-0' 2 2 2 3 3 3 3 3 3 3 3 3 3 3 4 NOTES: 1.BLOCK PADS ARE OPTIONAL. 2.BLOCK SIZES SHOWN ARE NOMINAL.PADS MAY CONSIST OF EITHER A SINGLE 16x16 BLOCK OR(2)16x8 BLOCKS. 3.BLOCK PADS SHALL BE PLACED WITHIN 12 INCHES OF EACH BUILDING CORNER.ADDITIONAL PADS,AS REQUIRED,SHALL BE SPACED EQUALLY. �lnnuu��p„ sF -' MASTER ANCHORING PLANS--FLORIDA--FBC 2017 * N0.77209 + * _ PROJECT NO. SHEET NUMBER STATE DATE: 11-15-2017 •:• ,rrr� ■�1■��VV 'x`11 '///��//J 1A.11D .b OFh��• P R 5.11 t ` .t} DRAWN BY: KLN V_(..(._I U �,rp'2 �ORlO 2 ■ ■ CHECKED By! KLN TABLE BUILDINGS REVISION: SCALE:1'=1'-0 II-IS•17