Loading...
HomeMy WebLinkAboutRevisions OFFICE USE ONLY: Q� t DATE FILED: PERMIT REVISION FEE: ��00 RECEIPT# PLANNING & DEVELOPMENT SERVICES BUILDING&CODE REGULATION DIVISION 2300 VIRGINIA AVENUE RECEIVED FORT PIERCE,FL 34982-5652 (772)462.1553 FEB 01 2018 APPLICATION FOR BUILDING PERMIT REVISIONS ST, Lucie County, Permitting PROJECT INFORMATION LOCATION/SITE ADDRESS: 7 Ls 0 L!24 le Or ✓� l=am,-t P. rye F t 3 y9 s l DETAILED DESCRIPTION OF PROJECT REVISIONS: _ l?e2 '9 CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: ST. LUCIE CO CERT. #: BUSINESS NAME: U Fr v C (,os s QUALIFIERS NAME: L),-„ I-,')0 +rJ, ADDRESS: I LJ CAL k;e 14 v.)rr CITY: STATE: j l'--1 ZIP: 3)qL-o PHONE(DAYTIME): -5- FAX: OWNER/BUILDER INFORMATION: NAME: ADDRESS: CITY: S';ATE: ZIP: PHONE(DAYTIM F,111 '• 9 FAX: ARCHITECT/ENG N I + T � NAME: bbb'��� ADDRESS: rl CITY: . NO 1 w ..r S A Zm. . PHONE(DAYTIME : FAX: Um SLCCC: 9/23/09 Revised 06/30/17 REVISION GENERAL NOTES: 1' CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION 2. THE DESIGN 8 CONSTRUCTION OF THIS STRUCTURE MUST FULLY COMPLY WITH THE 2017 FLORIDA MMP80N MIS30 wi(N)tmx tnm V) BUILDING CODE(STH EDITION),ACI 318-05,NCMA.NATIONAL FOREST PRODUCT ASSOC..NDS,TPI-95,AND NAILS FgpA NEW r x�'wALLreEAM ANY OTHER NATIONALLY RECOGNIZED ORGANIZATIONS THAT GOVERN THIS BODY OF WORK. '�Y'roBT' 5��' EieBTWOwNc.SFIAtroRFIMN •v 3. ALL WORK SHALL COMPLY WITH ALL LOCAL AND REGIONAL ORDINANCES. TO DESIGN PARAMETERS FOR WIND LOAD COMPLIANCE _ RECEIVED ON 8 F 1. RISK CATEGORY: 11 V) La 2. CODE REFERENCE: 2017 EXISTING FLORIDA BUILDING CODE(6TH EDITION) trz•cYPeuM 2017 FLORIDA BUILDING CODE(8TH EDITION)8 ASCE 7-10 r x r n sY.TOP PLATE aoFulo ITVP. \w P 3. BUILDING DESIGN: ENCLOSED FEB 01 2019 ATTACHEDTO EXISTWGTRUSS $ op WI LY%e•EMSED w/r x 1H' z 4. MEAN ROOF HEIGHT: <75.0' WASHER S.S.OR GALV LAo O D)rxr0SYP SFJ,Lt WI Sr cox FLITCH `�•/a�8 u 5. ROOF PITCH: 6/12 DEGREES ST,LUCIt CounCy,PMfDl It ng EA.ENO a 2V O.C. 7✓ 6. GCPII: ±018 --- •Laino- (OR EEO.)A OR0W of(z)i m 7. WI DTH OF END ZONE: A.4.D NAILS a M.END 61r O.C.MAx. O 8. WIND SPEED: 160 MPH(Vult)3-SECOND GUST NmesrR,w BEAM Assr.ro ExlST.rxrM `^ 124 MPH(Vasd)3-SECOND GUST CONCEALED FASTENERS OR ATTACHMENTS 9. WIND EXPOSURE: C NOTE NMST-12 OR ts)tse L'o 10. ADJUSTMENT FACTOR: 1.21 ARE THE RESPONSIBILITY OF THE NAILS®EA.END a 3r D.G.MAX. 11. LOADS: THROUGHOUT a FLOOR 40 PSF CONTRACTOR OF RECORD NEW WINDOWS,BEE PRODUCT APPROVAL {Tp m ROD/DEAD 17 PSF $m ROORLIVE 20 PSF R WALL 18 PSF IF1eTALLALLwwoowsa 12. SHEAR WALLS WERE CONSIDERED OOORS PER FMVAAMA 13011 9PECIFrATgNB FOR WATER 13. A CONTINUOUS LOAD PATH WAS PROVIDED TIGHT INSTALLATION \t1 I1i11j///// 14. COMPONENTS CLADDING DETAILED p 15. MINIMUM SOIL BEARING PRESSURE IS 2000 PSF PRESUMPTIVE rxr WOOD STUD w-W SIMPSON \\\\\Jit ..�•y�/� H2.SA TOP830TIOM W/l13)IC NALS IS \ L WINDOW AND DOOR NOTES: ALL MANUFACTURES LABLES SHOWING WIw NAILSOVO.C.ATTHEEEDGEsalW `\ •\ i O.C.IN THE FIELD(W13 N15UU TION) ` U FACTORS AND SHGC COMPLIANCE �' p ; 1. WINDOWS,DOORS,SHUTTERS,AND ALL COMPONENTS SHALL BE DESIGNED AND INSTALLED PER THE P.T.Y%1'SYP.BOTTOM RATE W/1N•X r: WTTT1 FBC ENERGY CODE MUST 3'EMBED.TAPCON9O EA END a te'O.C. .-. MINIMUM DESIGN PRESSURES AS PRESCRIBED IN THESE PLANS. •Z w ¢ Mq%.I WHERE HEW WALL MEETB E%IBT. 2. ALL F�(TERIOR GLAZING SHALL BE IMPACT RESISTANT OR HAVE PROTECTION PER SECTION R301.2.1.1 OF REMAIN ON ALL DOORS AND WINDOWS ATTAGN W/,/a•x 2trr ENDED.LAc �j V N J• - THE 2014 FBC RESIDENTIAL CODE.PROTECTION SHALL BE DESIGNED FOR THE SAME WIND DESIGN 11t`fiL INS^C-CTIONS ARE APPROVED SCREWS TOP/BOTTOM 3 CENTER PRESSURES AS THE WINDOWS OR DOORS THEY ARE COVERING. (STAGGERED) Z'•, \ 3. ALL WINDOWS AND DOORS ARE TO BE INSTALLED ON 2X PRESSURE TREATED BUCKS,AND AS PER i O EXISTING-FOUNDATION TO /,,f,•y^., -11R 1� MANUFACTURERS SPECIFICATIONS UNLESS OTHERWISE NOTED. RENAIN.VALE. 3>• ,FPR I TIMBER NOTES: 177((-a0a� ST.LUC'TF T T'.�•TY Ei `r. "' 1. EXTERIOR FRAME WALLS SHEATHING TO BE SHEATHED WITH 12'OR 5/8'APA SHEATHING,SPECIES j4Ry1F.W ED FOR COa1����F '�� GROUP 1,SPAN RATING OF 2410 OR BETTER.UNLESS OTHERWISE NOTED,INSTALL WITH FACE GRAIN YY //����`"'�� HORIZONTAL.PLYWOOD SHALL BE 4 PLY MINIMUM.NAIL TO STUDS USING ed NAILS®4.O.C.AT PANEL RlsV IGlyLll Ill e Y}�jlI EDGES AND W O.C.IN THE FIELD.DECREASE SPACING PER PLAN.AT SHEAR WALLS.NAIL TO EACH STUD sr� a AT THE END OF THE WALLS FOLLOWING THE EDGE SPACING.BACK OUT AND REMOVE ALL NAILS THAT DO I�AT� NOT FULLY PENETRATE/MISS FRAMING MEMBERS.. PLAN.3 AND PI'J),yV'�1 i•��T h! IV IL I UN JO 2. FLOOR SHEATHING TO BE 314'T&G COX SPAN RATED STRUCTURAL PLYWOOD,INSTALLED WITH FACE OR NO INAPRCPIO�W l�.l'6R �kDETAIL`'BAY WINDOWS GRAIN PERPENDICULAR TO FLOOR FRAMING GLUED&NAILED WITH 10d NAILS e'O.C.AT PANEL EDGES SCALE:12'•V-7AND 12'O.C.IN THE FIELD. 3. THE MINIMUM LUMBER GRADES SHALL BE AS SUCH: 3.1. INT.6 EXT.BEARING WALLS,TOP PLATES,WINDOW BUCKS,8 HEADERS: 3.1.1. SOUTHERN YELLOW PINE#2 OR BETTER 3.2. BOTTOM PLATES AGAINST CONCRETE: y 3.2.1. PRESSURE TREATED SOUTHERN YELLOW PINE 02 OR BETTER �fl w 4. ALL TIMBER IN CONTACT WITH MASONRY OR CONCRETE SHALL BE PRESSURE TREATED OR HAVE AN a APPROVED SEPARATING MATERIAL. 2'X 4.STUD WALL ATTACHED Tit 5. ALL NAILS AND METAL HARDWARE EXPOSED TO THE ELEMENTS SHALL BE GALVANIZED.ALL NAILS SHALL TO EXIST.WALL WI 114' p BE COMMON WIRE NAILS.SPACE NAILS AT STRAPS AS TO NOT SPLIT THE WOOD. TAPOONS(FOR CMU)C A.O.C. p L FROM EA COLUMN 6 IT STAGGERED CENTERS WIND LOAD DESIGN CRITERIA: THROUGHOUT c g 1. DESIGN WIND LOAD ON INDIVIDUAL ROOF TRUSSES BASE UPON TRIBUTARY AREA SHALL BE AS FOLLOWS. so O o 2. SEE ROOF PLAN FOR ZONE LOCATIONS. 3. OVERHANGS SHALL INCLUDE PORCHES,BALCONY ROOFS,ETC. „•, , A 4. MAXIMUM DEADLOAD RESISTING UPLIFT SHOWN BELOW SHALL BE B PSF. 8 (5)2'-0' .. EXTERIOR COMPONENTS ATTACHED TO THE WALL(SIDING,ETC): NOTE:DPssHOWNFORMULLEO '38 I NUMTS ARE FOR EA W WDOW W m 1. EXTERIOR WALL COMPONENTS SHALL BE ATTACHED PER MANUFACTURERS REQUIREMENTS TO MEET S THE WINO PRESSURES SHOWN. NOTE:ALL DIMENSIONS TD SE `� LS - vi g2. END ZONE IS AT EXTERIOR CORNER,UNDER ROOF ZONE 3.INTERIOR ZONE IS REMAINDER. VER1:ED IN FIELD i NOTE: ■PROVIDE VERTICAL 45 BAR _ �q WALL ZONE AT ALL CORNERS,EA SIDE OF WINDOWS .. 6DOORSa®ro.0 MAX. " END 35 PSF 28 PSF r INTERIOR 28 PSF 25 PSF FLOOR FRAMING PLAN SCALE:3010-1'-0' " S-1 1 1