Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 3 SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff SCIS Site Map Links Search PY Product Approval 0 I USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL15780-R7 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Soft-Lite LLC Address/Phone/Email 10250 Philipp Parkway Streetsboro,OH 44241 (330)528-1136 PLanga n@soft-lite.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Double Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity Farabaugh Engineering and Testing,Inc Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ryan J.King,P.E. Validation Checklist-Hardcopy Received Certificate of Independence FL15780 R7 COI (a)Certificate of Independence.Ddf Referenced Standard and Year(of Standard) Standard Year AAM A/W D MA/CSA 101/I.S.2/A440 2008 AAMA/W DMA/CSA101/I.S.2/A440 2011 AAMA/W DMA/CSA 101/I.S.2/A440 2005 ASTM E1886 2005 ASTM E1996 2006 ASTM E1996 2009 TAS 201,202,203 1994 Equivalence of Product Standards v�t�: Certified By Sections from the Code https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgt3e 1 SAInEOW... 1/3/2018 " Florida Building Code Online Page 2 of 3 Product Approval Method Method 1 Option D Date Submitted 10/07/2017 Date Validated 10/11/2017 Date Pending FBC Approval 10/17/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 15780.1 a."Imperial LS DI-112"Double Hung Extruded PVC Double Hung Window-(X/X Configuration) Window Limits of Use Installation Instructions Approved for use In HVHZ:No FL15780 R7 II (a)Inst 15780.1.Ddf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15780.1 for Design Pressure Ratings,any FL15780 R7 AE (a)Eval 15780.1.odf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15780.2 b."5400 DH54(G5405)"Double Extruded PVC Double Hung Window-(X/X Configuration) Hung Window Limits of Use Installation Instructions Approved for use in HVHZ:No FL15780 R7 II (a)Inst 15780.2.DdF Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15780.2 for Design Pressure Ratings,any FL15780 R7 AE (a)Eval 15780.2.odf additional use limitations,installation Instructions and Created by Independent Third Party:Yes product particulars. 15780.3 c."5400 DH54(G5405)"Double Extruded PVC Double Hung Window-(X/X Configuration) Hung Window Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15780 R7 II (a)Inst 15780.3.Ddf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15780.3 for Design Pressure Ratings,any FL15780 R7 AE (b)Eval 15780.3.Ddf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15780.4 d."5300 DHS3(135305)"Double Extruded PVC Double Hung Window-(X/X Configuration) Hung Window Limits of Use Installation Instructions Approved for use In HVHZ:No FL15780 R7 II (a)Inst 15780.4.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15780.4 for Design Pressure Ratings,any FL15780 R7 AE (a)Eval 15780.4.Ddf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15780.5 e."5300 DH53(G5305)"Double Extruded PVC Double Hung Window-(X/X Configuration) Hung Window Limits of Use Installation Instructions Approved for use in HVHZ:No FL15780 R7 II (a)Inst 15780.5.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15780.5 for Design Pressure Ratings,any FL15780 R7 AE (b)Eval 15780.5.odf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15780.6 r.Serles"Barcelona"Model"DH30I" Extruded PVC Double Hung"Impact"Window,Missile Level "C"-(X/X Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15780 R7 II (a)Inst 15780.6.odf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgt3e 1 SA1nEOW... 1/3/2018 Florida Building Code Online Page 3 of 3 Design Pressure:N/A Evaluation Reports Other:See INST 15780.6 for Design Pressure Ratings,any FL15780 R7 AE (b)Eval 15780.6.odf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15780.7 g.Series"Barcelona"Models Extruded PVC Double Hung"Impact"Window,Missile Level "DH30I"&"131-13013I" "D"-(X/X Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL15780 R7 II (a)Inst 15780.7.Ddf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15780.7 for Design Pressure Ratings,any FL15780 R7 AE (b)Eval 15780.7.odf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particul S. 15780.8 h.Series"Barcelona"Models Extruded PVC Double Hung"Impact"Window,High Velocity "DH30I"&"DH30PI" Hurricane Zone-(X/X Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15780 R7 II (a)Inst 15780.8.Ddf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15780.8 for Design Pressure Ratings,any FL15780_ R7 AE.,.,jbI„Eval 15780.8.Ddf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15780.9 i.Series"Barcelona”Models"DH30" Extruded PVC Double Hung"Non-Impact"Window-(X/X &"DH30P" Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL15780 R7 II (a)Inst 15780.9.Ddf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15780.9 for Design Pressure Ratings,any FL15/80 R7 AE (a)Eval 15780.9.Ddf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Coovrmht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395."Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here. Prod�ucctt Approval Accepts: fes` ,1 va EF E Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgt3el SAhiEOW... 1/3/2018 R W R W Building Consultants, Inc. B Consulting and Engineering Services for the Building Industry C P.O.Box 230 Valrico,FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No.9813 Product Report 'I I No.: i i Octoberi Product Sub Category Manufacturer Product Name Category Soft-Lite LLC "Barcelona" Windows Double Hung 10250 Philipp Parkway Model"DH301"&"DH30PI" Streetsboro,OH 44241 Double Hung Window (330)528-3400 "Impact" Scope: Product Evaluation report issued by R W Building Consultants, Inc.&Lyndon F. Schmidt, P.E. (System ID#1998)for Soft- Lite LLC., based on Rule Chapter No.61 G20-3, Method 1 D of the State of Florida Product Approval, Department of Business&Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E.do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 6th Edition(2017)Florida Building Code(FBC)structural requirements including the"High Velocity Hurricane Zone". 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in"HVHZ",this product complies with Section 1626 of the FBC and does not require an impact resistant covering. 4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-15780.8 require further engineering analysis by a licensed engineer or registered architect. 6. This product meets the water infiltration requirements for"HVHZ'. 7. See drawing FL-15780.8 for size and design pressure limitations. Supporting Documen s: 1. Test Report No. Test Standard Testing Laboratory Siqned by TEL 03001734 TAS 201,202&203-94 Testing Evaluation Lab., Inc. Lyndon F.Schmidt, P.E. 2. Miami Dade NOA Materials Testing 17-0712.04 Saflex° PVB Interlayer(Eastman Chemical Company) 15-0528.13 PVC Extrusions(Vision Extrusions Ltd.) 3. Drawing No. Prepared by Signed&Sealed by No. FL-15780.8 RW Building Consultants, Inc. (CA#9813) Lyndon F.Schmidt, P.E. eeeueni►q� 4 Calculations Anchoring RW Building Consultants, Inc. (CA#9813) .. ��`F.... ..SCH.�a j���s Signed F. Sealed by BuckSchmidt, P.E. ASTM E1300 Glass Load Lyndon F.Schmidt, P.E. `��� �;•'`�0 E N Sic'•°• ��i� `v 5. Quality Assurance :~ No 43109 ° Certificate of Participation issued by Farabaugh Engineering and X*; =_ X Testing, Inc,certifying that Soft-Lite LLC is manufacturing products within a quality assurance program that complies with ISO/IEC :: 5TA's 17020 and Guide 53. . p . �/• sS'yOEyEf,I. 0Lyndon F.Schmidt,P.E. It"S11111110 FL PE No.43409 10/11/2017 Sheet 1 of 1 Li ............. Sote _ � Windows `�`� z '��1" �W'•. :yGJ`z °nom � t BT-inging quality to tight.. ' ����� �`•; i dm o 10250 Philipp Parkway r n I t O N• .z Sfreehboro,Ohio 44241 f� v c+ o z° 9m CW "BARCELONA" _SEE CHART FOR SEE CHART FOR v a rng SRxM r— FRAME SAES FRAME SIZES a 4 a W Model "DH301" and "DH30P1" E o= -- o Cw 0 3d DOUBLE HUNG WINDOW "IMPACT' Uj �Z N ail as GENERAL NOTES 1. This product has been evaluated and is in compliance with the 6th Edition(2017) " a N Florida Budding Code(FBC)structural requirements including the"High Velocity /% /;% &I a Hurricane Zone"(HVHZ). y I a a 2. Product anchors shad be as listed and spaced as shown on details.Anchor X X Q3 embedment to base material shad be beyond wall dressing or stucco. 3. When used in the"HVHZ'this product complies with Section 1626 of the FBC and does not require an impact resistant covering. z 4. For 2x stud framing construction,anchoring of these units shall be the some as that — shown for 2xbuck masonry construction. Model"DH301" Model"DH30Pl" N 5. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered architect. b i 6. This product meets the water infiltration requirements for the"HVHT'. 8 TABLE OF CONTENTS MAX. MAX. GLASS DESIGN PRESSURE(PSF) SHEET# DESCRIPDON MODEL FRAME D.L.O. g 1 Typical elevations,design pressures and general notes DIMENSION DIMENSION TYPE POSITIVE NEGATIVE 1201 o wrE: 4114177 i 2 Hor¢ontal cross sections 9 ` N.7.5. _ "DH30I" 54.0"X 76.5 46 25"x 33.875" GI +55.0 65.0 sc� € 3 Horizontal cross sections avc BY. JK m g 4 1 Vertical cross sections 5 Buck and frame anchoring "DH30PI" 54.0"X 76.5 46.25"x 33.50" G1 +55.0 65.0 aac BY.. LFS ; r 6 Components DIRAwrx N0' 7 Component o FL-15780.8 8 B81 of materials and glazing detail SHEET 1 or 8 e v Hardware Notes: 1 2 �4 � �EMB. IN. 1. Locks(2)located on lock ra0 4 4 YP.J 10'from each jamb. �'• '• n n C SEE DETAIL 1 SEE ANCHORING SHEET d) i 24 33 28 8 G1 g`•� ~�"� 2 INTERIOR INTERIOR z oo ec N .:c 24 7 U N C== v o xz< 3 �e zm a p uY 56 oa maa� E �z W � X . 13 9 25 1 � 3 a o z EXTERIOR EXTERIOR 3 E 1 0 3 Z rvi em NEn 3 4 5 1 =c 4 4 2 HORIZONTAL CROSS SECTION DETAIL T G N E 2 Shown Direct to Masonry •� B a a } LL C A m ^ 24 SEE DETAIL 11-1/4"MIN. C — SEE DETAIL 1 M 33 28 8 G1 EMB.(TYP.) 24 33 28 8 G1 INTERIOR Y INTERIOR Z o Of 0 ' I I n 13 9 13 9 s 0 EXTERIOR K EXTERIOR z ° 5 1-1/4"MIN. DrM� 4/14/17 i EMB.(TYP.) SME. N.T.S. 1 E € oxc.er: JK m Y 1 HORIZONTAL CROSS SECTION 1 3 cxK LFS 3 R 2 2X Buck Construction HORIZONTAL CROSS SECTION owwNc ra.: �>Shown w/1 x suck ` n FL-15780.8 a N O SHEET�Of 8 Q R:%OientASoR-LHe Permanent\A-Florida Product Approvals\FL-15780 Double Hung\C-Drawings\FL-15780(2017)\FL-15780.6-8.dw9,3 Z O ° m n A cc A T Z FF �G awl W N = 0 O �• _ o m 14 N n Qo s� J Z o^ L0 A ° W O m m O w •0 Q w � A b �v M D p0 A N H 0 xD Co 0 N N Z W m v -0 D_ W i* — Q PRODUCT: Documents Pmpa By: '' c 3 SOFT—LITE WINDOWS Lyndon F. Schmidt �,� �•'•��ON•'� � IW I y, P.E. No. 43409En PART OR ASSEMBLY: G� BUILDING CONSULTANTS, INC. 1. P.O. Box 230, Valrlco, FL 33595 CD CD v NO DATE BY HORIZONTAL Phone No, 813.859.9197 REVISIONS CROSS SECTIONS FSPE C.A. No. 9813 0 201 7 R.W.BUILOINe CD—L-118 Ill. R:\Olents\SoR-Elle PennaneM\A-Florida Product APINWalAFL-15780 Double Munq\C- Drawkps\FL-15780(2017)\FL-15780.6.84w9,4 1-1/4"MIN. EMB.(TYP.) I-1/4"MIN. * I EMB.(TYP.) A � _ N A � w n T JO •O W N to T oQ, A o O 1�o N 0 01, t $ Z N A O N A O 0 A T 1-1/4"MIN. o, EMB.(TYP.) A . • � b •o w N S T r) O 0 70 �0 � z W 1,, N A A EMB.(TYP.) N T m A !P � m v N W m 0 ' A A N .. 175 O• v • �A w nn �a N I Cl Q O SIC Z '• O A V r O ♦♦♦♦\1111111///// 1-1/4"MIN. EMB.(TYP.) 1.957 1.957' No.43A09 ' Xzj PRODUCT: Devum•ne. rr"..Pe-dne SOFT—LITE WINDOWS Lyndon F. Schmidt �; �OMOR•' �` P.E. No. 43409ss•�NAL•' ♦♦♦ 'ZA \♦ 6 N BUILDING CONSULTANTS. INC. m 0D `1 NO DAT VERTICAL J� P•0• Box 230, Valrico, FL 33595 BY CROSS SECTIONS Phone No.: 813. 59.9197 REVISION$ FBPE C.A. O 201 7 RAV.811-1—co.+eu�r..+la iHc. No. 88 `1111 11// !q' n (TYP I - 10.5"O.C.jTYP.I d) J 1 1 ///rrrrn 1u111\1\ o.°° z U N•, V U p z 2X BUCK F h 10 m c°w J p -- -SASH I X BUCK G a a m a`a DIRECTTO w 7X BUCK _ MASONRY H E a z BUCK < FRAME HEAD&JAMBS c w 1 0 (TYP.I MEETING ------_-- z — RAIL -- -- 0 2X BUCK M 3 = MASONRY o OPENING IXBUCK K z MASONRY DIRECTTO D 3 r OPENING SASH1. MASONRY E THROUGH TILT w LATCH BLOCK 0 U 0 Y i O 0m i• � a a M G i FRAME ANCHORING BUCK ANCHORING u g z 0 a $ CONCRETE ANCHOR NOTES: 1.Concrete anchor locations at the comers may be adusted to maintain the min. edge distance to mortarjoints. 2.Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to maintain the min.edge distance to mortarjoints,additional concrete anchors $ may be required to ensure the"MAX.ON CENTER"dimension are not exceeded. I -" t 3. Concrete anchor table: z ANCHOR ANCHOR MIN. MIN.CLEARANCE MIN.CLEARANCE TYPE SIZE EMBEDMENT 70 MASONRY TO ADJACENT z EDGE ANCHOR c w,E 4114117 ITW TAPCON� 1/4" 1-1/4" 2" 4" SCALE N.T.S. 5 ELCO ® 1/4" 1-1/4- -- 1" 4" Mc.ur: JK m CHK.ar: LFS 3 � WOOD SCREW INSTALLATION NOTES: OP"W NO.: 1.Maintain a minimum 5/8"edge distance,I"end distance,&I"o.c.spacing of FL-15780.8 n wood screws to prevent the splitting of wood. SHEET 5 or 8 6 R:\clients\Soft-Ute Pennanent\A-Florida Product Approvals\FL-15780 Double Hung\C- Drawings\FL-15780(2017)\FL-15780.6-8.dw9,6 N 0 V ul oo Q � y T O 0.66" N w w m � � O noo � w U H 0.065" 1.63" T 2.87' 0.95"-- w m 00 = o m 0.86" A w p o — 8 °w 0.09" t+ T F1 0.065" Fes—1.05,—moi �e 00 1.44" 0.35" 0.37' N A 0.64" p 0.05r o O a 511511 t11/71j7'' E0,27---I .�`. of.SCHIy�O 0.94" / _ N0.43409 p Q 4 PRODUCT: Documents Prepared By: ` SOFT—LITE WINDOWS Lyndon F. Schmidt ��� Ss••�?.... •p ` P.E. No. 43409 s1pNAl11�` PART OR ASSEMBLY: q�WBUILOINQ CONSULTANTS, INC. hN v COMPONENTS P.O. Box 230, Valrlco, FL 33595 bo NO DATE BY Phone No.: 813.659.9197 REVISIONS FBPE C.A. No. 9813 0 2017 R.W.BUILDING CDNBULTANte INC. R:\Oknts\Soft-LRe Pennanmt\A-Florida Product Appmals\FL-15780 Double Hung\C- Drawings\FL-15780(2017)\FL-15780.8-8.dwg,7 2.8T' I►-121"--{ El 1.96" .g 1.83" TIM P O CD 1.01.21" 2 —� W A tis N u C o y i � y a 2.39" 1.21"-- A 0 o y o �0 0 cF1 041" 00.OS' 0.84" 1.96" CH$J�O'i'�i No.43409 9 PRODUCT: Document,P.sP=nBy: d •t, ; A AZ SOFT—LITE WINDOWS Lyndon F. Schmidt •'• O!!!ON Iv P.E. No. 43409 y//,ONAl1tt�\`� ? GD BUILDING CONSULTANTS, INC. PART OR ASSEMBLY: JL I03 Do o N to v COMPONENTS P.O. Box 230, Volr cc, FL 33595 m NO DATE BY Phone No.: 813.859.9197 R I$ION$ FBPE C.A. No. 9813 0 z0 1 R.w.BU110—Cotes--te U+c. BILL OF MATERIALS ............. 116M• MATEdAL / m A 1 X BUCK SG>=0.42 WOOD B 2X BUCK SG>=0.42 WOOD =V �:, ^ <__ =Ni d 2, C 1/4"MAX.SHIM SPACE D 1/4"X 2-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL E MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI CONCRETE h> 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 �hq n,. �� z c'o 0 F #8-15 X 2"TRUSS HEAD SMS(1.9/8"MIN.EMBEDMENT) STEEL ^ 'o'N z G 114"X 2-3/4"HWH ELCO OR ITW CONCRETE SCREW STEEL H 1/4"X 2-1/4"HWH ELCO OR ITW CONCRETE SCREW STEELN 9 0`o a K 1/4"X 3-1/4"PFH ELCO OR ITW CONCRETE SCREW STEEL 4 g 4'� m d a 4 M #10 X 2-3/4"PPH WS 41.3/8"MIN.EMBEDMENT) STEEL z' 1 FRAME* PVC ii 2 HD' PVC c �' EA 3 WEEP HOLE COVER' PVC 4 SILL ADAPTER* PVC 5 TOP UFT HANDLE' PVC v H= 6 KEEPER RAIL' PVC o za 7 LOCK RAIL' PVC z w 8 PLAIN STILE' PVC ~U 9 GLAZING BEAD' PVC 5/8"GLASS BITE DOW 2400 SAS z pU 10 BOTTOM LIFT RAIL' PVC 11 REINFORCEMENT 16065-T5 ALUM) ALUM. 7/r THICK m2 12 REINFORCEMENT(6065 T5 ALUM) ALUM. 1/8"ANNEALED '^ 0 0 13 REINFORCEMENT(6065-T5 ALUM) ALUM. C� 0.090'SAFLEX PVB INTERLAYER a I a 14 HEAD POCKET INSERT" PVC 15 SLOPED INSERT* PVC 1/$'ANNEALED m 16 SLOPED SILL` PVC 20 LOCK - AIR SPACE 21 LOCK KEEPER 24 PLT LATCH BLOCK C3 1/8"ANNEALED OR TEMPERED GLASS* = 25 TILT LATCH 26 #8 X I"PFH T EK STEEL STIP INTERCEPT SPACER o $ 27 #6 X 1"PFH TEK STEEL Gl talAUIG 28 WEATHERSTRIP(187-270TRI-FIN) 29 BULB SEAL 30 BULB SEAL 0 31 PIVOT BAR STEEL "HVHT'GLAZING NOTES: i a 32 #7 X 3/4"PFH TEK STEEL 1.GLAZING>36"WIDE REQUIRES TWO(2)SETTING BLOCKS CONFORMING TO FBC SECTION 2411.3.3.1 0 8 33 BALANCER BRACKET 2.*TEMPERED GLASS IS REQUIRED FOR EIGERIOR GLASS GREATER THAN 30 FEET ABOVE GROUND. < j a •THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BE PRODUCED BY 5 EXTRUDERS LICENSEES IN"AAMA CERTIFICATIONS PROGRAMS FOR RIGID PVC EI RUSIONS". 0 0 z � S OAC 4/14/17 i SME, N.T.S. ' ED avc.err: JK o CHK.BY: LFS ; DRAWIW NO.: R o n ,°� FL-15780.8 0 s�rtcr 8 OF 8 0 t f 4: 4,2 s44� �1 measureSet Mise C]]�Af�f��rrr u Delayed Order tics EXTERIORS I\1 PACT AA'I NDOM";AND DOORS 1918 Corporate Drive,Boynton Beach,FL33426 866. 1-5332Office 561-732-0300 Fax 1y, f f State Specialty License#SCC13'1150472 CO2NTRACTAGREEME\T I x +` I To �1n Cate Sheart City_ 0t it- IV, FL zip { Emru �i—G e—Lc Ar r,a Ph. -1 —�•1 11 Paradno F_xtenors a rtes to moasuro, unh and install the foticwin roduds for Ne amount elputated bala,r All walk td tvt mpteted in workman➢lee F` f r Y f e�1 le a mannor acmrding to Flonda code and standard pmcticps.Paradise Exlerion will haul away all lob re,atad debns Paradiso Extonom m not responsiCW 7+y°f 4 t s ;f I 7 for removing or replacing any tum�shtmgs,or ha glrgs on inlenor or exterior we no veer complimanta:y sevix on wotK port�god All mar:uY°Cur2r ftf l- fir warranties Provided at wmµeti n. AA•as anal h me bale bcrare 1978' N No o woo Inc io a ltistoriralpFtrict Ya No zF:T`� HOAApproval X-ded:Yc. Nt1 Ptajoctevabodela)tdduet0IlI0AaPPro•aI; S.\a Qty Style Location Size Color ufacturer 1 Soft Lite 2 3 4 S t � ��� Grade 6 D a Pam Z ' 8 ( f1 } Frames 10 - 1- tiIn3 A lt+ 11 1 �; class 12 �r f 13 Q�t` tri tS z i 14 Ate, f s IS (1 It If sulated LOF\E 366 16 GritL. 17 !� \owl 19 , Obscured 20 1 21 Total w inl s Total Doors Total Other tie' NOTES G 5 �— Gt olal Sale Price , BUYER'S RIGHT TO CANCEL Deposit BUYER MAY CANCEL THIS CONTRACT BY DELNERMG WRITTEN NOTICE TO THE SELLER ANY TIME PRIOR TO 940NIGHT OF THE THIRD BUSINESS DAY Corurencenent cJ„' AFTER THE DATE OF THIS TRANSACTON BUYER l USE THIS CONTRACT a .,,,ver v •vn AS 7 M4T NOTICEBY WRITING I HEREBY CANCECAT THE BOTTOIAAND. Financed Balance ADDING BUYERS NAME AND ADDRESS THE NOTICE MUST SE DEL"ERED Finance TO THE SEU.ERATTHE ADDRESS SHOWNASOVE ' Payme��i-oM.vJ Lacn J�sx 3%Convenience Fee FprAll Cradr•Card Paymac:.s An tnatervl m Guaranteed to be as specified AS work.is 10 be completed in a werkman4ke manner according to standard practices.This contract",."d only wnN proper aMlnaturos:Paradise Ederlora eha0 no be held retpenslble for rime and tnatenal dalays,etnkes,acts of God or any other R.;ifl b bvford Its control0,ner a aglees"I the equity in this proerty pu sawnry for this cO nUacl-Since,thus contract calls for nada to order gaods.It'a not subject to canx,ti lix exxpi s stated above.Stat inslababon appronmate,y &12 week(s)from after sacuring permit.HOA finance approvaL Verbal prornisas can cause msundeMtandnga, tf Mfone this contract:cansbMas the entire urieerstmdulg of”par-jai,and no other urderstandarp.Collateral,verbal or othenvnse.shag De'bimins.unless vgned by both part-Paradise Ex,ar iara is to remove and haul avray at lab related.data's.All"lei and discourxs all.led.All charges included above Thank you for yourorderlll x - a x — B6' SIGMA U BUYER SIGNATURE 1)A4, X RF.SENTAr1V SIGNATURE D.ATE PARADISE EXTERIORS "Building Our Quality Reputation One Customer At A Time SCC131150472 Property Information Building Information Owner: ALINE LLOYD Wind Zone: 170 MPH. Address: 3208 MARAVILLE BLVD. Exposure Category: C FORT PIERCE,FL 34982 Minimum Building Dimension: 39 ft. Mean Roof Height: 12 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) JElevation(ft) Pressure(psf) Pressure(psf) 1 Int 25 61 7 37.7 -40.9 2 End 25 61 7 37.7 -50.3 3 Int 25 61 7 37.7 -40.9 -- __._ --- — _ 4 Int 25 61 7 37.7 -40.9 5 Int 25 61 7 37.7 -40.9 ----- —........ 6 End 18 36 7 37.8 -50.6 7 Int 52 36 7 37.2 -40.4 8 Int 18 61 7 37.8 -41.0 9 Int 25 61 7 37.7 -40.9 10 End 25 61 7 37.7 -50.3 11 Int 36 36 7 37.8 -41.0 .,r to Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.51h Edition(2014)Florida Building Code. Page 1 of 1 WINDOW& DOOR OPENING INFORMATION A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Corner Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING MULLION SHUTTERS NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF DIMENSIONS REQ Y/N SIZE REQ Y/N/NA 1 Int window 7/8"Lam,IG FL 15780.8 55 65 37.7 -40.9 1 54 x 76.5 25x61 No No 2 End window 7/8"Lam,IG FL 15780.8 55 65 37.7 -50.3 54 x 76.5 25x61 No No 3 Int window 7/8"Lam,IG FL 15780.8 55 65 37.7 -40.9 54 x 76.5 25x61 No No 4 Int window 7/8"Lam,IG FL 15780.8 55 65 37.7 -40.9 54 x 76.5 25x61 No No 5 Int window 7/8"Lam,IG FL 15780.8 55 65 37.7 -40.9 54 x 76.5 25x61 No No 6 End window 7/8"Lam,IG FL15780.8 55 65 37.8 -50.6 54 x 76.5 1806 No No 7 Int window 7/8"Lamm IG FL 15780.8 55 65 37.2 -40.4 54 x 76.5 5206 No No 8 Int window 7/8"Lam,IG FL 15780.8 55 65 37.8 -41.0 54 x 76.5 18x61 No No 9 Int window 7/8"Lam,IG FL 15780.8 55 65 37.7 -40.9 54 x 76.5 25x61 No No 10 End Window 7/8"Lam,IG FL 15780.8 55 65 37.7 -50.3 1 54 x 76.5 25x61 No No 11 Int Window 7/8"Lam,IG FL 15780.8 55 65 37.8 -41.0 54 x 76.5 3606 No No