Loading...
HomeMy WebLinkAboutProduct Approval ck, l�.vri»fk. o.a�ry ..1'�' i�_" BCIS Home I Log In I User Registration i Hot Topic j Submit Surcharge i Stats&Facts ; Publications i FBC Staff f BCIS Site Map ± Links Search i rb� �`.�� f Product Approval USER:Public User L��'".�adrnirr Product Aooroval Menu>Product or Application Search>Application List>Application Detail FL# FL17347-R2 r••-��J Application Type Revision Code Version 2017 Application Status Approved Comments Archived ❑ Product Manufacturer Plastpro Inc./Nanya Plastics Corp. Address/Phone/Email 5200 W CENTURY BLVD. LOS ANGELES,CA 90045 (440)969-9773 Ext 16 rickw@rwbidgconsultants.com Authorized Signature Vivian Wright rickw@rwbidgconsultants.com Technical Representative Scott Johnson Address/Phone/Email 5200 W Century Blvd. Los Angeles,CA 90045 (440)969-9773 Ext 18 scottjohnson@plastproinc.com Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ryan J.King,P.E. ❑ Validation Checklist-Hardcopy Received Certificate of Independence FL17347 R2 COI (a)Certificate of Indeoendence.Ddf Referenced Standard and Year(of Standard) Standard Year 101/I.S.2/NAFS 2002 AAMA/WDMA/CSA101/I.S.2/A440 2008 ASTM E1886 2002 ASTM E1996 2002 ASTM E330 2002 ASTM E331 2000 TAS 201,202,203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL17347 R2 Eauiv (b)Equivalency Of Standards.odf Sections from the Code Product Approval Method Method 1 Option D Date Submitted 08/13/2017 Date Validated 09/26/2017 Date Pending FBC Approval 09/29/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 17347.1 a.Fiberglass Door "Non-Impact"Fiberglass Glazed Door-Single with or without Sidelites(X,OX or XO,OXO)Outswing/Inswing Configurations up to Nominal 6'8 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17347 R2 II (b)Inst 17347.1.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.1 for any additional use limitations, FL17347 R2 AE (b)Eva[ 17347.1.pdf installation instructions and product particulars. Created by Independent Third Party:Yes 17347.2 b.Fiberglass Door "Non-Impact"Fiberglass Glazed Door-Double with or without Sidelites(XX or OXXO)Outswing/Inswing Configurations up to Nominal 6'8 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17347 R2 II (b)Inst 17347.2.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.2 for any additional use limitations, FL17347 R2 AE (b)Eva[ 17347.2.pdf installation instructions and product particulars. Created by Independent Third Party:Yes 17347.3 c.Fiberglass Door "Non-Impact"Fiberglass Glazed Door-Single with or without Sidelites(X,OX or XO,OXO)Outswing/Inswing Configurations up to Nominal 8'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17347 R2 II (b)Inst 17347.3.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.3 for any additional use limitations, FL17347 R2 AE (b)Eval 17347.3.odf installation instructions and product particulars. Created by Independent Third Party:Yes 17347.4 d.Fiberglass Door "Non-Impact"Fiberglass Glazed Door-Double with or without Sidelites(XX or OXXO)Outswing/Inswing Configurations up to Nominal 8'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17347 R2 II (b)Inst 17347.4.1)df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.4 for any additional use limitations, FL17347 R2 AE (b)Eva] 17347.4.pdf installation instructions and product particulars. Created by Independent Third Party:Yes 17347.5 e.Fiberglass Door "Impact"Fiberglass Glazed Door-Single with or without Sidelites(X,OX or XO,OXO)Outswing/Inswing Configurations up to Nominal 6'8 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17347 R2 II (b)Inst 17347.5.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.5 for any additional use limitations, FL17347 R2 AE (b)Eval 17347.5.odf installation instructions and product particulars. Created by Independent Third Party:Yes 17347.6 f.Fiberglass Door "Impact"Fiberglass Glazed Door-Double with or without Sidelites(XX or OXXO)Outswing/Inswing Configurations up to Nominal 6'8 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17347 R2 II (b)Inst 17347.6.1)df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.6 for any additional use limitations, FL17347 R2 AE (b)Eval 17347.6.1)df installation instructions and product particulars. Created by Independent Third Party:Yes 17347.7 g.Fiberglass Door "Impact"Fiberglass Glazed Door-Single with or without Sidelites(X,OX or XO,OXO)Outswing/Inswing Configurations up to Nominal 8'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17347 R2 II (b)Inst 17347.7.12df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.7 for any additional use limitations, FL17347 R2 AE (b)Eval 17347.7.odf installation instructions and product particulars. Created by Independent Third Party:Yes 17347.8 h.Fiberglass Door "Impact"Fiberglass Glazed Door-Double with or without Sidelites(XX or OXXO)Outswing/Inswing Configurations up to Nominal 8'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17347 R2 II (b)Inst 17347.8.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.8 for any additional use limitations, FL17347 R2 AE (b)Eval 17347.8.12df installation instructions and product particulars. Created by Independent Third Party:Yes _17- 17347.9 i.Fiberglass Door "Non-Impact"Fiberglass Opaque Door-Single with or without Sidelites(X,OX or XO,OXO)Outswing/Inswing Configurations up to Nominal 6'8 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17347 R2 II (b)Inst 17347.9.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.9 for any additional use limitations, FL17347 R2 AE (b)Eval 17347.9.pdf installation instructions and product particulars. Created by Independent Third Party:Yes 17347.10 j.Fiberglass Door "Non-Impact"Fiberglass Opaque Door-Double with or without Sidelites(XX or OXXO)Outswing/Inswing Configurations up to Nominal 6'8 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17347 R2 II (b)Inst 17347.10.12d Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.10 for any additional use FL17347 R2 AE (b)Eva[ 17347.10.Ddf limitations,installation instructions and product particulars. Created by Independent Third Party:Yes 17347.11 k.Fiberglass Door "Non-Impact"Fiberglass Opaque Door-Single with or without Sidelites(X,OX or XO,OXO)Outswing/Inswing Configurations up to Nominal 8'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17347 R2 II (b)Inst 17347.11.Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.11 for any additional use FL17347 R2 AE (b)Evai 17347 11 odf limitations,installation instructions and product particulars. Created by Independent Third Party:Yes 17347.12 1.Fiberglass Door "Non-Impact"Fiberglass Opaque Door-Double with or without Sidelites(XX or OXXO)Outswing/Inswing Configurations up to Nominal 8'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17347 R2 II (b)Inst 17347.12.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.12 for any additional use FL17347 R2 AE (b)Eval 17347.12.odf limitations,installation instructions and product particulars. Created by Independent Third Party:Yes 17347.13 m.Fiberglass Door "Impact"Fiberglass Opaque Door-Single with or without Sidelites(X,OX or XO,OXO)Outswing/Inswing Configurations up to Nominal 68 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17347 R2 II (b)Inst 17347.13.Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.13 for any additional use FL17347 R2 AE (b)Eva]17347.13.Ddf li installation instructions and product particulars. Created by Independent Third Party:Yes 17347. 4 n.Fiberglass Door "Impact"Fiberglass Opaque Door-Double with or without Sidelites(XX or OXXO)Outswing/Inswing Configurations up to Nominal 6'8 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17347 R2 II (c)Inst 17347.14.adf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.14 for any additional use FL17347 R2 AE (b)Eval 17347.14.odf limitations,installation instructions and product particulars. Created by Independent Third Party:Yes 17347.15 o.Fiberglass Door "Impact"Fiberglass Opaque Door-Single with or without Sidelites(X,OX or XO,OXO)Outswing/Inswing Configurations up to Nominal 8'0 in Height Limits of Use Instmiation Instructions Approved for use in HVHZ:No FL17347 R2 II (b)Inst 17347.15.pd Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.15 for any additional'use FL17347 R2 AE (b)Eva(17347.15.Ddf limitations,installation instructions and product particulars. Created by Independent Third Party:Yes 17347.16 p.Fiberglass Door "Impact"Fiberglass Opaque Door-Double with or without Sidelites(XX or OXXO)Outsiv)ng/Inswing Configurations up to Nominal 8'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17347 R2 II (b)Inst 17347.16.Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.16 for any additional use FL17347 R2 AE (b)Eval 17347.16.adf limitations,installation instructions and product particulars. Created by Independent Third Party:Yes 17347.17 q.Fiberglass Door "Impact"Fiberglass Opaque Door-Single with or without Nominal 14"Sidelite(s)(X,OX or XO,OXO) Outswing/Inswing Configurations up to Nominal 6'8 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17347 R2 11 (b)Inst 17347.17.Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.17 for any additional use FL17347 R2 AE (b)Eval 17347.17.Ddf limitations,installation instructions and product particulars. Created by Independent Third Party:Yes 17347.18 r.Fiberglass Door. "Impact"Fiberglass Opaque Double Door with or without Nominal 14"Sidelites(XX or OXXO)Outswing/Inswing Configurations up to Nominal 6'8 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17347 R2 II (b)Inst 17347.18.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17347.18 for any additional use FL17347 R2 AE (b)Eval 17347.18.udf limitations,installation instructions and product particulars. Created by Independent Third Party:Yes Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. : R W R W Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry C P.O.Box 230 Valrico.1,33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No.9813 ProductEvaluation ' •„ ISeptembet-25,2017 Product Sub Category Manufacturer Product Name Category Plastpro Inc. Opaque Fiberglass Doors Exterior Swinging Door 5200 W.Century Blvd. Doubles Doors Assemblies Los Angeles,CA wl or w/out Sidelites Phone 440.969.9773 Inswing!Outswing-"Impact" Scope: Product Evaluation report issued by R W Building Consultants, Inc.&Lyndon F.Schmidt,P.E. (System ID#1998)for Plastpro Inc.,based on Rule Chapter No.61 G20-3, Method 1 D of the State of Florida Product Approval,Department of Business&Professional Regulation. RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 6th Edition(2017)Florida Building Code structural requirements excluding the"High Velocity Hurricane Zone". 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with FBC Sections 1609.1-2&R301.2.1.2 and does not require an impact resistant covering.This product meets missile,level"D°and includes Wind,Zone 4 as defined in ASTM E1996 and FBG Sections 1609.1.2.2&R301.2.1.2.1. 4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-17347.14 require further engineering analysis by a licensed engineer or registered architect. 6. See.drawing FL-17347.14 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 01391141 ASTM E330-02, E331-00 Testing Evaluation Lab.,lnc. V. K.Wright TEL 01390617 ASTM E330-02, E331-00 Testing Evaluation Lab.,lnc. V.K.Wright TEL 01650058 TAS 201,202&203-94 Testing Evaluation Lab.,lnc. Lyndon F.Schmidt,P.E. TEL 01391120 TAS 201,202&203-94 Testing Evaluation Lab.,lnc. William B.Shelton, P.E. 2. Miami-Dade NOA Materials Testing 17-0712.05 Saflex°PVB Interlayer(Eastman Chemical Company) 3. Drawing No. Prepared by Signed&Sealed by No.FL-17347.14 RW Building Consultants, Inc. (CA#9813) Lyndon F.Schmidt,P.E. 4. Calculations Prepared by Signed&Sealed by Anchoring RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. 5. Quality Assurance Certificate of Participation issued by National Accreditation and Management Institute, certifying that Plastpro Inc.is manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and �IstIS a6'1e"®F,e Guide 53. p�0 �,SC)-14 o eon Oma@• �•°' °F•1 �.J°®®6 No 43 0 n °e STAT_ OF Lyndon F.Schmidt,P.E. FL PE No.43409 912512037 Job 18 Sheet 1 of 1 P.1014%%P4Im Inc PEP NENntA•fha,W,Product AppYozhVL•17341 Htmrylga Doer•Impaehnar�lmpactlC•Drawingsul•1t3478TH CD 110/7AF4f7I4t,14.1Aawq,FL•174dt,1d fif Ny0'O W�tw(n ALIN.• ��}}�33��D{bD{b W S�tT' �� � - �r mx<x N N , - q� eta Z �".. fA p 5 Fe Qj S1 g B2'OVOALL FRAMA HEIGHT P'. VAILLFRAME 112Y OVERALL HEIGM (GUISWWG) n of Z O n a t3 >< �o Zm 4 I�I+���f�� ry OO N I1Yr ®•�� •moi O�l`�1 J ImE3 + ' �t O �J_iPA�iJ" F�'gy1 G z 6C��/b / No.434DB •1 I�g '� � vNbbucr: p N pOdumanl.areno.yu Iry! ! q PLq.STPRp 17GC L .d F.Sdhmldt // '•pjfcony�.•••• `,�\ F80 PIOE(IGlAS5 6f7 P.C.NDS s3d08 ///FS/OeTlA'�j1 `� q W y w 1 6PD4iE 10 BiN ED. pAPT Dq_ASc�j/,p4y, '/'(/(y DUILDIMC CONSULTAND,IHC, j�t4_• I d 1 UPDA E r �r B, 10 F JK IW A A 0 E &GNLEO230,Vbl .,FL 06 PRSSURESfENANTES Pha.e noa Dl a,osD.Dtat 4;i i1B 14 R.W.DUIlO1Nu BBHR114f.HTb IRw G FDP •,A,No.0tlf� 1..\tl16MIAINCp%IM PCAMANENT%A•FI&W4 PrMud APPr IAFL-17347 Nbergl3st DW.I,opW- II,,McAC•M-ing,%-173479TH ED(2R7J1FL•17341.1).146g,22 . 74.25 MAX.PANEL HEIGM! 1.75, I E. 131—,11 zi 13 ro�, 3. S k 7L��,4�5 13 f� A 0 E!o o G g M 1>0 `�O��F1SCHMjO �;:•'iycfaiag'••7' No.43408 s' g qq g PRCp17Ci; ooeom.me aepa.ea 9y<�� - P INC. Ly.d P� 9cHrnldt � ��''•0,,.'+ n FMCW ASS DOOR a,C.M.43499 �i� tQNAt �� �ryy ''tnnnnry 27 4F DATE TO 9TH ED. 201] F9C JK PgRi OR ASSEMBLY: �/p f1UILtlING CONSULTANTS,INC. 1 4 1 DATE i'0 STH ED. 2Ot4 FBC JK DOOR L/U P.O.Da.230,Yotrtco.FL 33595 lw 4 0 Al BY PANEL DL7A LS Phone No.:813.959.9197 PION FDPC CA No.9873 oz.1 d N.W.puiwiwo pmieuL.Aw,e Iwo• iltllent,\M,%tpro,InC PEWANENTSA-Florida Pradutt ApixmalAFL•17347 ROef0lut Dw•Impatl-MMImp&I%C•Dluw(ng350Ld73d)6TN FD pOlTA4l•191a7.17•la.d.y a3 Oo 11 O •� /jam b' V /T�� Q `/wl^11�t 1Iw{ 1 OZ•+ N Irn ® W J k to t ON� X �� VfPn W P Ww '34. 13 b W W O f W O aO V b � bW V PN fnN b P V•'VCEN9Ei'•.�' �: Np.43409 • PROOUCiI. necumeMe onoeroa qr�i,,�4� PUS)PRO INC. �i�C'••''•......,Dl O • � �Zy� o CIRERG(A35 DCDR pia No.Faaa69 lot �/Sy. DFFJ�`'f_\���• Z 7727 1 UPDATE TO 9N ED. aP 7 OC JK .....\\ $ V T m I 6 la 73 uF'WTE rD OM Ea. 0 fOG pAR(OR AS5ELIBLVI LO 9UIlDING CONSULTANTS•INC. JK to t/L P.O,Bow 230,Valrtno,FL 33599 IV +NO DATE I N _ ELEVA91dNS Phone No.:613.859.9197 POPE C.A.No.9613 (1 ZG1 d q,W.DUI�PIMn�9N6YLTwq{q Iqn. LAOi—INNasiprn,Ino pERMANDIPA-Fofidz ftdu App MIXFL-173!7 Fi"Las1 D04r-Vnpetl—o paAC-D,a%SsV1-175478TH ED 12017AEL-17347.13-14dwg.51 O Ny m n �r � 0s P a • Ca A O _n10 O n 0� ` ILIp O 22 f Z 0 U tl1 o- p = Q N � n ? o �A N � ..z o .o oED �s m p .• r. a m�P1 0' �o I� 0.15'C•SINK 0.15"C-SINK InPI In PI EMa I»P.I ;``\\V �ENH...... EMB.PP.) qA �� � � pg vaooucr: 9«„m.a�P„P,,.4 BF•''� ~ "' PUS7PF(tl INC. Lyndon F.S Idt IN x o6o FIBERGLAS$pQOR P.E.NP.aJaD9 // ` \\\\ I7 1] UPDATE TO 6TH E0. 2 1 fB dK PART OF ASSEMBLY, BUILDING CONSULTANTS,INC. F In 104114115 UPDA7 TO STN CO. 2 14 FDC �N & �°q p,0.Bo.250,Valrtao,FL!7603 I01 a 4L 0 DATE OFVI I N BY CROSSZSECTAIO 9( TOUCH) Peon•No.:613.869.8197 FOPE CA.No,B81] 0301 B R.W.BUILCiNd CUMnYLTaH}p INo. 31CliontAPlallp(o,I6C PEAMANWNA•Florida Pmduct AppmvalstFL-17347 Fiberghu Door-Impaa- Imp3d\C-DrawingsVL.173476TH ED(2017)VI.-17347.13-1446g.63 N •� 4 ID �� g 9 V n fla mm g0 �� a £ �a N Z s A z P N fn O O F� F� p b a D � n O PC Pa w Pw PC n� o y4 A b0 PC z I� n � • I-1/4•MIN. 1-114*MIN. FMB.ITYP.( EMB.(IYP,l G if No.47408 r 9.zt PRODU Ioocumenis vmPe.eo ey:�, F79EENGlASS DOOR aYcATPRINC. �iie f easas Idt P• 8 11y`m 2 ]2]1] UPDATE TO 6M m. 201] Fill JK FART OR ASSEMBLY: @��/BUILDING CONSULTO ,E INCE IV y+ 1 Id IS UPDATE TO STN ED. 2014 FBL JK JLI/1/ P.O.Bo.I30,Volrivo,FL 33593 t" a NO A CROSSZSECTIONS(vl%nBUCK) VV Ph No.:al3.859.9197 • REVISIONS FBPE C.A.No.9813 + U a016 N.W.DUILbINb DON°uLT.Nle lwv. kNarntgwastpm.lnc PE MAND4M-Randa PludwlApWr alAFL-1734]FlW9lass Dow-MpK-wimpad\C-Waw'nga�L•17341 fiTN 6o 11017J<i4173E7.13-ladNg,31 �+- —7925 MAX.PANEL H6GHi —•�� 1 0 cl n 1 d d w•� 41 i a _ � z n � A 0 N N N ' S C� cq C t.rs--I q N m Z `{{t{11 t111J7J//JJ No.45408 ' $ PRODUCT: veau------------ 9y:;,,•, r'13 751 Pl7LSfPRO INC• LYvA r,SeN.rfid, 4201LOA•'�`; I� a Z pQ FlBERGIA$5 DOOR ., Nv.a5a09 �iJl{QQ��NI t�1,`` • Q y{y 2 772-7T?-7- -f 17 IJ UPDATE FO tlTN E0. 1017 FDC JK PART OR A55EMBI Y! �]�{BUILD CONSULYA1i15�INC. IV ± x y 104/14/15 UPO.{TE i0 STN tD.(1014 FBC JK SIDELITE R�/(� P•0,b W 230,Velriee,FL 33595 a >NO DATE PANEL OETAIL5 Phnne Nae 813.659.9197 I I N _.PDP6 O.A.No•0013 O as t a w.w.�wuvi.ao cv.vuuraw•v uay. LWL-A stpm,. PEttMANENTkA=Elbtide Plbduti AWISEL-17347 Rbelgbn Dam-bbpact-n .pa°1C-D,-kpVLL-273476TH ED 017AFL-11141,13.14dVo 7.7 DO ^ gr �a 4 P- F __ ' ae- y5 — n N V R m � 0 0 O 0 V N g�o � ®o O m n V W Q O n A r. A r`Ir �n �° p �o V to A S Lis..,. EMS.MIN, EM9.cTYP J I-I/4°MW. EMB.(IYR) • �� V•"110EN0B'•.�' No.43609 L PRODUCT: ....menu +ane„ "F, - r PLASTPRO INC. LVndb9 P.9bhmld4 434•' . FIBERGLASS DOOR P.C,Nb.43409 a z o T ghu1NAL3Tp� R -t m 2 7 27.17 UPDA7ETO 6734 ED. 2017 FBC JK BUII PART OR ASSEMBLY: V/� NO CONSULTANTS INC. lu H x in I a I DATC TD snT ED. z°ts FHC JK HORAI&VERTI CAL CROSS ✓LUl/ '.O�bbw 230,Vbi Idd,PL 33595 ,. 0_DATE _ SECRDNStZONi(DIRECT TO MASONRY) phone Nae 81.959.9197 REVISIONS 'BPC C,A.Nb.9913. 172819 R.W.Buribrnq bbH411LT.N70 Irv.. t�Kny�plislp�a,(„ap@pinpN6NrV,-tlrnitls PrtduaApinwalflrl•i7H7 fieargles+0acx-Unpact+anl+•+w��E•pm^n9r1T41r)d>67H t012917M473a7.13•uewg,al 1•I/M�MIN. I-it4"MIN. EMB:1„./Pr( EMB."P.j 0 o s 4(� P N O D z � a v EMB.PYP.) I-1/4'MM EMB.iIYP.} mw m z r" O c IA n w 0 m� . � Pr �. SL � o P N �f� to `•' \\/�} m \:J fill. `vY'' +. r q 4i //3 No,43809.. 1•I/4°nuN. Z` � ci k zit EMB.(VP.( 5 r'S R PtASYFRd tNC. LyaEon F.schmWt �iC0R19�:+•�y2.�• 1 g g c FIBERCIl55 DOOR P.E.Na.a340B r�44i�d'NA4Yt`�• m z ^ ~ t a T4 tl UP TE TO BTN 6O. 2017 FBG Jt{F q/ BtJLLDINO CONSULTANM 1k0. TE TO STH E: 2014 FBG JK r•GP.O.004 230;YOM",FL 93595 Vt++NQ GAESEG(tONS(TNRESHDLdSJ P9PE CA.No..9at3... _ O o.1 a A.W.Bu�Loa.B Go�ou�T�vre Irv. L14ie4tslwastpm.Ort PERLMENI>,q-FImMA Noduet Apprv,IAFL-17347 FCerylmsOwr-Imp40ww4impacgC-DrawingsVL-173476TH ED(2M7AFL-1734/.13-14dwq 91 EnN .oma r IS Is MAX. T m 3 1.75 R 4 MIN. 3 I m r. jQy� n .o IYv c HIM 2-O mo z > N f 0 b s �4b C- MAX ��� m 3 IS' r�� • o O MIN. 1-t/4"MIN, £ a / v ° n ea- _ EMB.gyp.) O �3::A ° L-3 f0'ZZ� �H rn z Z $ Fy N n rn 0 FRI •o w g � 1-I/4'MIN, g x z EMB.Vyp.) on / o o N � z Z MIN.� M is 2 °4 MAX. �y `,1111u1Nllall� F SCN..... ' ' Np.43409 ' rilr-12 Y•' PRODUCT: Doeumonb Prepena EIBERCUS$DOOR PC Ne.F 43409 lat ' '% $ D'•• `` ••' ����` //111111 $ V --t m 7 77 1] UPMTE 10 6TH W. 2017 EBC JK ppgT OR ASSEMBLY: BU11J]WC CONSULTANTS,INC. I _ x IA-- I 4 14 1 POA7E 70 STM E0. 2014 F'BC JK lW P.O.Boe 230.ValMco,tL 33993 a N U SECT 0N5 DDIREC�TO MISONRY) Pnone Ne.:e13.es9.9t9y R ION$ FDPE C.A.No.9813 O zOt a w.w.Bunowo gaNeuLr,.Nra INc. Inc FTRM"ENTNA-Florida Product App—ISVI.-11347 Fbaglau Door- D—irgAR-17347 6TH ED(2E)I7AFL-17M7.l3-I4,d,,q,102 1 1� ti 0 t 14ro.c. MAX.VYP) (TYPI 17�T PYP) 1,10,43409 T in 1p— "I",P—Scnmld4�F -El y;s I FIBERGLASS DOOR P.E.No 4}409 i. : suLT FBC JK PART OR ASSEMBLY. 8 ING CON UPDATE TO OW ED.(2017) X Tn 1 —4/1-4—/1-5 UPpgiE W STH ED.(2014) JLO DATE BUCK ANCHORING P.O.B.".230.Wrlo.PL J3506 Ph- .:813.659,9197 -A. —L......... ISIDNS POPE C.A.No.9313 Co. 0; 1-p -4 1 1 -n rn z 14,0Z RJRMAX,VYPI Iro.c -t MAX(TYF)—�--1 MIR) N5 a 9.3t"FROM lop Of JAMB J11 -1 26 il.N MM a �1 377 2.7 m 3,P BY T 0S os Z' If. '4 19M 3819'MOMTO F 5- Of ASTRAGAL 1'w ,! w.'434 LAO r43O09 d- 1A POAIC TO ST"CD 017 FUC INO CON SULT �T DUILDS'INC. I I, T. ST EM M4 FSC .0,Ubw 230,V.01m PL MOO S Pnone HANOWAREN.A 813,05a.9107 REVISIONS N., 4 aM. t.... ,C,AMtpm,Inc pEAmANENTIA.Pl I&PlW..APP—lAPL-l7347 66.35'MAK LIGHT FRAME HEIGHT 62.63"MAX D10.HEIGHT > I"MAX I OP) mp-) fis 0 7,6, GLAAlING 65.75MA7r LIGHT --H' r_.71. log AZO 3A dal q I Ile WI 1111"I No, 4340 PL4smo INC, Ly.d IZ U, ...........40%, plgrRa s DOOR P.E.Nb.a3A08 17 LDIN 4 kl. P.O.e..230,We—FL 33595 p RW 8—n-ai3.asg. z 111111101. S 7 2 UPDATE TO IM_10 F1'll CONS... 'Ll .17 41 15 C.UTWIMALS FDIC BILLOFMATERIALS 456' ����� !TEAT! DA[R7fnON MA7ENAL '101. '•" • •v���;i�i n A 1X BUCK(G>=0.42) WOOD 4.56, z_V'& a B 2X BUCK(G>=0.42) WOOD C 1/4'MAX-SHIMSPACE :72�-' DT/4'PFHCONCRETE SCREW{i-1/4'MIN.EMB.) STEEL I �l' _ F. E MASONRY-3.O00PSI MIN.CONCRETE CONFORMING TOACICONCR[TE �-244'—t-213'—� 24ADATHRESH0ID 301 OR HOLLOW BLOCK CONFORNINGTO ASTM C90 F 1/4'X3.3/SPFHETCOORtEWCONCRETESCREW STEE. T POLY FlBER JAMB 'h�lht 11 PLL���� uyn'z G 3/I6'x3.1/4'PFH ITW CONCRETE SCREW STEEL LEn 1 lArX2-3ArPRiEiCOORAWCCkNICRElESCREW 47E&J /210 X T PFH WOOD SCREW STEEL \ ra 5 o e m L tl 10 X 2-1/7 PFH WOOD SCREW(].IS-MIN.EMB.) STEEL 5 M 3/16°.X2-114°ITWCONCRETE SCREW STEEL - N 114')( -114" FH CONCON CONCRETE STEEL 5---- 4.56' F� _-'Oey 7 P 114'X2-U4'PFHEI.0000NCRETESCREW STEEL 456' 1 POLY OBER JAMB COMP. 20 INSWING THRESHOLD 22@0IfI WING iHRIIHOID 9 6 DOOR SWEEP PVC End�ao(Laalwl Endura Rsefim) 7 WEATHERSTRIP(ENDURA FORCE 5) FOAM Smm I� 8 WEATHERSTRIP(4LONJ FOAM I21•� SB)EUTE ADAPTER 9 #9 x 3/4"PFH WOOD SCREW STEEL ADAPT a: 11 4'X 4'HINGE STEEL 12 LATCH STRIKE PLATE STEEL !„ o g 13 DEADBOLT STRIKE PLATE STEEL 20 INSWING THRESHOLD ALUM/COMP 21 INSWING THRESHOLD w/SIDRITEADAPTER ALUM/COMP 23 22 OUTSWINGTHR(SHOLD ALUM/COMP 456' 23 OUTSWING THRESHOLD w/SIDEURE ADAPTER ALUM/COMP INSWING iHRLSNOLDw SIDELNEADAPLER ^OUfSWING IHRL'SHOLD w/SIDEIIfE ADAPTER 3 24 ADA THRESHOLD ALUM 21 DW=(LSeriesl Endesa(Lderiesl 'm & 25 Ol1I5WINGTHR[SHOLD ALUM/WOOD 26 INSWING THRESHOLD ALUM/WOOD m 27 INSWING THRESHOLD w/SIDELITEADAPTER ALUM/WOOD 456- I- 4sr 33 ASTRAGAL(DLP OR ENDURA) ALUM 40 DOOR PANEL - 50 SIDELITE PANEL -L E i > OURN7NG THRESHOLD 26 INSWINGTNRESHOLD25 o 0 2CONCRETEANCNOR:NOTES DRP DIP 8 1.Concnte onoha"cut""at"m corners may be ocWed to momtdn the mh edge datance to morlorphsts 2 Comet.anchorlo..5—noted."MAX ON CENHR"to of be adyuted to 1 JS rr,dddn me min.edge c6istance to modarloints,adQtiond concede anchors § 2wborequired to mare the IMAX ON CENSER-dnordon ono note edod. 7� f A Conn t anchortable: I i ANCHOR'ANCHOR -MIN. IN.CLEARANCE..MIN.CLEARANCE 511B'OSUDE BOLT TYPE SNE' fh1UEDMEW •TOMASONRY - TOADJACENT 5/16'05UDE BOLT Z EDGE ANCHOR'' ITTH�W® N (2THROW® _ a,E:?Q/08114 _ HW6UIIDIX J/ffi' 1.1/4' S' 1.1 EACH END) EACH END) stun N.T.S. Is TA ON, 1 4' 1.7 P 7 4' BOLT RETAINERII 1 o.a IN.. JK ' s" ELCO lµ' 1.1/C P 4' CONCEALED F- 457' -i a:x: LFS ; d ULTRACOI� h- S WOOD SCREwWSTAl1nnON NOTES ASTRAGAL �� ENDURA ASTRAGAL l_Maidanorniriumrrn:5//lredgodssoxo.J•entl dssLmxm6a'a.c.spocing of 33 OLP 33e� eB �11NSWMG THRESHOLD w/SIDFL1fEADAPIER fL-7734774 ° 3 ­d­;a reven topt tho4,2I g.Iv .d. IXP r stn 77 a a3 '�