HomeMy WebLinkAboutProduct Approval MIAMI-DADE COUNTY
I1AM PRODUCT CONTROL SECTION
7,771 1D11805 SW 26 Street.Room 208
DEPART. ENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
-NOTICE OF ACCEPTANCE OA «.miam ladesm /cconom,,
GAF
5T
FI
1 CampusDriveLE [018
Parsi a NJ 07054 CO P
pp y' � . Lucie County, Permitting
SCOPE'
This NO is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in M�ami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NO shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product o material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, t ie manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend t e use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is de ermined by Miami-Dade County Product Control Section that this product or material fails to meet the
requireme its of the applicable building code.
This prod ict is approved as described herein, and has been designed to comply with the Florida Building Code
including he High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Woodland®Shingle
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall'be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 14-1022.23 consists of pages 1 through 4.
The submi ted documentation was reviewed by Alex Tigera.
MIAM E COUNTY
NOA No.: 16-1012.19
• • Expiration Date: 04/05/22
Approval Date: 03/23/17
Page 1 of 4
i
ROOFING ASSEMBLY APPROVAL
CategoryRoofing
Sub-Category: Asphalt Shingles
Material: 4-Tab
Deck Ty e: Wood
SCOPE:
This approves GAF Woodland® as manufactured by GAF as described in this Notice of Acceptance, designed to
comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code.
PRODUCT DESCRIPTION:
Manufactured by Test Product
A licant Dimensions Specifications Description
GAF Woo i dland"Shingle 17"x 40" TAS 110 Fiberglass reinforced heavy as weight halt roof
g P
shingle,with 4-tabs.
MANUFACTURING LOCATION:
1. Mt. Vemon, IN
EVIDEN E SUBMITTED:
'Test Aizencv Test Identifier Test Name/Revort Date
PRI Aspha t Technologies GAF-321-02-01 TAS 100 10/31/11
Underwriters Laboratories, Inc. I ICA48725 ASTM D 3462 12/09/11
Underwriters Laboratories, Inc. 1 ICA48725 TAS 107 12/09/11
Underwriters Laboratories, Inc. 1 ICA48725 ASTM E 108 12/09/11
LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
NOA No.: 16-1012.19
M CouN7Y Expiration Date: 04/05/22
Approval Date: 03/23/17
Page 2 of 4
i
I
INSTAL ATION:
1. Shing es shall be installed in compliance with Roofing Applications Standard RAS-115.
2. Flashi g shall be in accordance with Section 9.3 Option "B" (step-flashings) of Roofing Applications Standard
RAS- 15.
3. The anufacturer shall provide clearly written application instruction.
4. Expos re and course layout shall be in compliance with Detail "A",attached.
5. Naili shall be in compliance with Detail"B",attached.
LABELI G:
Shingles s all bear the imprint or identifiable marking of the manufacturer's name or logo,city and state of
manufact ring facility,and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade
County P duct Control Seal as shown below.
MIAW)ADE COUNTY
BUILDIG PERMIT REQUIREMENTS:
Applicati n for building permit shall be accompanied by copies of the following:
1. Thi Notice of Acceptance.
2. Any other documents required by Building Official or Applicable building code in order to properly evaluate the
inst llation of this material.
NOA No.: 16-1012.19
C Expiration Date: 04/05/22
AP ROVED Approval Date: 03/23/17
Page 3 of 4
DETAIL A
COURSE LAYOUT
Sty dGLE <..
INS AUATION
Stay.at either rake and
lay I i either darectlon
F Course:
with full shingle, �
Trin 3mm)notch.
See d Course; 0040
Tri 5"(127mm) r
off f rst shingle
ThI Course:
Tri 1)"
)
Off shingle
Course; F
Tri 15'
381
oft t shkrglgle Ine m) /
\ �-
C Ming firs
,5 � \ Place t course of shingles
the :ir \ 1/4'–3/4•(6-19mm)over as"and
1 st 4th course ,d rake edges Covering starter course
i ions on the overhang.to provide drip edge.
Ining courses,
staO ng the flffh course
DETAIL B
OVERALL DIMENSIONS AND NAILING PATTERN
40'
(1016mm)
Aligrrrtent Notch
is-ta•
16,-t ti• cross.-Awsm—Mt
s -u' 9• it
Mkm-tet
(432mm)
HANCED NAILING PATTERN-six nails per shingle
END OF THIS ACCEPTANCE