Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2 Business & Professional Regulation SCIS Home Log In i User Registration • Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links Search b' Product Approval pr 4 USER:Public User Product Approval Menu>Product or Aoolication Search>Aoolication List>Application Detail o RECEIVED FL# FL10124-1120 Application Type Revision FEB Code Version L2017 7 2�1$ Application Status Approve ST. Lucie County, Permitting Comments Archived Product Manufacturer GAF Address/Phone/Email 1 Campus Drive Parisppany,NJ 07054 FILE COPY (800)766-3411 mstieh@gaf.com Authorized Signature Robert Nieminen lindareith@trinityerd.com Technical Representative William Broussard Address/Phone/Email 1 Campus Drive Parsippany,NJ 07054 (800)766-3411 TechnicalQuestionsGAF@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/20/2018 Validated By John W. Knezevich,PE -/ Validation Checklist-Hardcopy Received Certificate of Independence FL10124 R20 COI 2017 01 COI Nieminen pdf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2015 ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2011 TAS 107 1995 Equivalence of Product Standards Certified By Sections from the Code https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQ WtDquracBeVCbdM... 2/1/2018 Florida Building Code Online Page 2 of 2 Product Approval Method Method 1 Option D Date Submitted 09/20/2017 Date Validated 09/27/2017 Date Pending FBC Approval 09/28/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 10124.1 GAF Asphalt Roof Shingles Fiberglass reinforced 3-tab, laminated,5-tab and hip/ridge asphalt shingles Limits of Use Installation Instructions Approved for use in HVHZ: No FL10124 R20 II 2017 09 FINAL ER GAF Asphalt Approved for use outside HVHZ:Yes Shingles FL10124-R20.pdf Impact Resistant:N/A Verified By: Robert Nieminen PE-59166 Design Pressure:N/A Created by Independent Third Party: Yes Other: Refer to ER, Section 5. Evaluation Reports FL10124 R20 AE 2017 09 FINAL ER GAF Asphalt Shingles FL10124-R20.odf Created by Independent Third Party:Yes Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Cooyrioht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click herr-. Product Approval Accepts: L ME ® dAac Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=WGEVXQwtDquracBeVCbdM... 2/1/2018 Florida Building Code Online Page 1 of 2 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links S II Product Approval F _ USER:Public User > > >Application Detail FL# FL10124-1120 FILE COP) Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer GAF Address/Phone/Email 1 Campus Drive Parisppany, NJ 07054 (800) 766-3411 mstieh@gaf.com Authorized Signature Robert Nieminen lindareith@trinityerd.com Technical Representative William Broussard Address/Phone/Email 1 Campus Drive Parsippany, NJ 07054 (800) 766-3411 TechnicalQuestionsGAF@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/20/2018 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2015 ASTM D3161 2016 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquracBeVCbdMQNZD6Zesy3 B... 2/1/2018 Florida Building Code Online Page 2 of 2 ASTM D3462 2010 ASTM D7158 2011 TAS 107 1995 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 09/20/2017 Date Validated 09/27/2017 Date Pending FBC Approval 09/28/2017 Date Approved 12/12/2017 Summary of Products FL# Model, Number or Name Description 10124.1 GAF Asphalt Roof Shingles Fiberglass reinforced 3-tab, laminated, 5-tab and hip/rid asphalt shingles Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER, Section 5. Evaluation Reports Created by Independent Third Party: Yes Contact Us::2601 Blair stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not se electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuar Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email addr they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wis supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee Chapter 455,F.S.,please click here. Product Approval Accepts: ❑ re-t ❑ C-edi- Gerd Safe a https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquracBeVCbdMQNZD6Zesy3B... 2/l/2018 EXTERIOR RESEARCH&DESIGN, LLC. Certificate of Authorization#9503 353 CHRISTIAN STREET,UNIT#13 OXFORD,CT 06478 (203)262-9245 EVALUATION REPORT FRE CnDv GAF I Evaluation Report 01506.01.08-1122 1 Campus Drive FL10124-1120 Parsippany, NJ 07054 Date of Issuance:01/03/2008 (800)766-3411 Revision 22:09/20/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6`"Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: GAF Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: 5?.xS y = X: Robert J.M.Nieminen,P.E. �jar����rr�sJsThe facsimile seal appearing was authorized by Robert Nieminen, Florida Registration No.59166 Florida DCA ANE1983 P.E.on 09/20/2017.This does not serve as an electronically signed dowment. CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Prope Standard Year 1507.2.4/1507.1.1, Physical Properties ASTM D1970 2015 R905.2.3/R905.1.1 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011 1507.2.7.1,R905.2.6.1 Wind Resistance TAS 107 1995 3. REFERENCES: fnfitt Examination Reference Date GAF(PDM 1915) Letter of Equivalency Seal-A-Ridge Impact Resistant IR 01/13/2012 PRI(TST 5878) Physical Properties GAF-025-02-01 03/27/2002 PRI(TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004 PRI(TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005 PRI(TST 5878) Physical Properties GAF-324-02-01 12/01/2011 PRI(TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013 UL(TST 1740) ASTM D3462 93NK6295 11/29/1993 UL(TST 1740) ASTM D3462 99NK43835 01/12/2000 UL(TST 1740) TAS 107 94NK9632 03/29/2000 UL(TST 1740) ASTM D3462 01NK06632 02/02/2001 UL(TST 1740) ASTM D3161,TAS 107 OINK9226 05/21/2001 UL(TST 1740) ASTM D3161 OINK37122 12/18/2001 UL(TST 1740) ASTM D3462 OINK37122 12/19/2001 UL(TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002 UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002 UL(TST 1740) ASTM D3161 03CA5367 03/11/2003 UL(TST 1740) ASTM D3462 03NK26444 10/17/2003 UL(TST 1740) ASTM D3462 04NK13850 06/07/2004 UL(TST 1740) ASTM D3161 04NK13850 06/23/2004 UL(TST 1740) ASTM D3161 04NK30546 03/10/2005 UL(TST 1740) ASTM D3462 04NK22009 05/06/2005 UL(TST 1740) ASTM D3161 04NK22009 05/09/2005 UL(TST 1740) ASTM D3462 05NK27924 02/10/2006 UL(TST 1740) ASTM D3161 05NK27924 02/11/2006 UL(TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006 UL(TST 1740) ASTM D3161,D3462 06CA18074 06/16/2006 UL(TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006 UL(TST 1740) ASTM D3462 06CA31603 12/01/2006 UL(TST 1740) ASTM D3161,D3462 06CA41095 12/27/2006 UL(TST 1740) ASTM D3161 07NK05228 03/13/2007 UL(TST 1740) ASTM D3161 06CA31611 04/04/2007 UL(TST 1740) ASTM D3161 06CA61148 04/09/2007 UL(TST 1740) ASTM D3161,D3462 07CA31742 11/08/2007 UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 03/13/2008 Exterior Research and Design,LLC. Evaluation Report 01506.01.08-1122 Certificate of Authorization X9503 GAF Asphalt Roof Shingles Revision 22:09/20/2017 Page 2 of 6 Eniipf Examination Reference Date UL(TST 1740) ASTM D3161,D3462 07CA55908 04/01/2008 UL(TST 1740) ASTM D3161,D3462 09CA10592 03/26/2009 UL(TST 1740) ASTM D3161,D3462 09CA06856 05/15/2009 UL(TST 1740) ASTM D3161,D7158,D3462 09NK06647 08/01/2009 UL(TST 1740) ASTM D3161,D7158,D3462 09CA27281 08/27/2009 UL(TST 1740) ASTM D3161,D7158,D3462 10CA35554 03/05/2010 UL(TST 1740) ASTM D3161,D7158,D3462 10CA13686 05/15/2010 UL(TST 1740) ASTM D3462 IOCA07264 05/27/2010 UL(TST 1740) ASTM D3462 10CA11953 10/29/2010 UL(TST 1740) ASTM D3161,D7158,D3462 IONK11951 10/30/2010 UL(TST 1740) ASTM D3161,D7158,D3462 1ONK12070 11/04/2010 UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 01/30/2010 UL(TST 1740) ASTM D3161,D7158,D3462 10CA53934 03/31/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48924 10/22/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA47919 12/03/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48408 12/08/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48725 12/09/2011 UL,LLC.(TST 9628) ASTM D3462 12CA34891 10/12/2012 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 12CA58151 02/15/2013 UL,LLC.(TST 9628) ASTM D3161 12CA38083 02/26/2013 UL,LLC.(TST 9628) ASTM D3161 13CA32332 06/18/2013 UL,LLC.(TST 9628) ASTM D3161 13CA37934 08/02/2013 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4786875675 07/17/2015 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4787434542 05/17/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mobile,AL 10/25/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Myerstown,PA 10/20/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tuscaloosa,AL 11/11/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Michigan Cty,IN 11/01/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Shafter,CA 11/17/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Savannah,GA 11/11/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Minneapolis,MN 10/25/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mt.Vernon,IN 10/25/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Baltimore,MD 10/21/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tampa,FL 11/17/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Dallas,TX 11/04/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Ennis,TX 11/03/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Fontana,CA 11/01/2016 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Marquis® WeatherMax®, Royal Sovereign® and Sentinel® are a fiberglass reinforced 3-tab asphalt roof shingles. 4.1.2 Camelot®, Camelot® II, Fortitude'", GlenwoodTM', Grand Canyon®, Grand Sequoia®, Grand Sequoia® IR, Grand Sequoia® ArmorShieldTM', Monaco®, Sienna®, Timberline® American Harvest®, Timberline® ArmorShield" II,Timberline® Natural Shadow®,Timberline HD®,Timberline®Cool Series®,Timberline Ultra HD®and Woodland®are fiberglass reinforced,laminated asphalt roof shingles. 4.1.3 Slateline®is a fiberglass reinforced 5-tab asphalt roof shingle. 4.2 Hip&Ridge Shingles: 4.2.1 Seal-A-Ridge® Ridge Cap Shingles, Seal-A-Ridge® IR Impact-Resistant Ridge Cap Shingles, Seal-A-Ridge® ArmorShield'" Ridge Cap Shingles and Timbertex® Premium Ridge Cap Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. Exterior Research and Design,LLC. Evaluation Report 01506.01.08-1122 CMIJffiaoee ojAudro*adon 19503 GAF Asphalt Roof Shingles Revision 22:09/20/2017 Page 3 of 6 4.3 Accessory Starter Strips: 4.3.1 Pro-Start® Eave/Rake Starter Strip Shingles and WeatherBlockerTM Premium Eave/Rake Starter Strip Shingles are starter strips for asphalt roof shingles. 4.3.2 QuickStart® Peel & Stick Starter Roll is a is a mineral-surfaced, fiberglass-reinforced, self-adhering SBS modified bitumen starter strip, nominal 9-inch x 33 ft roll,for use with asphalt shingles with exposure of 6- inch or less. 4.3.3 StarterMatchT" Starter Strip Shingles are color-coordinated starter strips for use with Grand Canyon® and Grand Sequoia" series asphalt shingles. StarterMatch" are installed as the second starter for Grand Canyon®and Grand Sequoia"series installations. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable for use in all wind zones up to Vasd= 150 mph (V„it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 The GAF hip & ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vasa=150 mph(V,,it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Starter Shingles or Starter Strip: 6.2.1 Installation of Pro-Start Eave/Rake Starter Strip Shingles,WeatherBlocker Premium Eave/Rake Starter Strip Shingles and QuickStart Peel&Stick Starter Roll shall comply with the GAF current published instructions. 6.3 Asphalt Shingles: 6.3.1 Installation of asphalt shingles shall comply with the GAF current published instructions, using minimum four (4)nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions: ➢ Camelot, Camelot II, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Sequoia ArmorShield, and Woodland require minimum five(5)nails per shingle. ➢ Slateline requires minimum six(6)nails per shingle. 6.3.2 Fasteners shall be in accordance with manufacturer's published requirements,but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the GAF for details. Exterior Research and Design,LLC Evaluation Report 01506.01.08-1122 Certificate of Authorization#9503 GAF Asphalt Roof Shingles Revision 22:09/20/2017 Page 4 of 6 6.4 Hip&RidRe Shingles: 6.4.1 Installation of Seal-A-Ridge Ridge Cap Shingles, Seal-A-Ridge IR Impact-Resistant Ridge Cap Shingles and Seal-A-Ridge ArmorShield Ridge Cap Shingles shall comply with the GAF current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and nominal 0.25-inch diameter beads of Henkel"Loctite PL S30 Roof&Flashing Sealant". 11.5 Sealart 1• j292 mm) 1° Sellante (25 mm) (25 mm) Enduit d'6tanch6it6 I • • 12" ( (305 mm) Nail Clavo 6 5/8'-7 5'8" Clouer (168-194 mm) I 12" (305 mm) 6.4.2 Installation of Timbertex Premium Ridge Cap Shingles shall comply with GAF current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and beads of Sonneborn NP1 Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant. a k 6.4.3 Fasteners shall be in accordance with GAF published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. Exterior Research and Design,LLC. Evaluation Report 01506.01.08-R22 CettpwteofAuftwhaon09503 6 EDITION(2017)FBC NON-HVHZ EVALUATION GAF Asphak Roof Shingles Revision 22:09/20/2017 Page 5 of 6 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. H. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA962S;(847)664-3281 END OF EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report 01506.01.08-R22 CerhykateofAuthorkatloni9503 6"EDITION(2017)FBC NON-HVHZ EVALUATIC'. GAF Asphalt Roof Shingles Revision 22:09/20/2017 Page 6 of 6 Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa,FL 33647 (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,6T"EDITION(2017) Manufacturer: ATLAS ROOFING CORPORATION Issued September 30, 2017 2000 Riveredge Parkway,Suite 800 Atlanta, GA 30328 RECEIVED (770)612-6267 FEB 0 7 2018 Quality Assurance: UL LLC(QUA9625) ST. Lucie County, Permitting SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1507.1.1, 1518.4, 1523.1.1, 1523.6.5.2.1 FILE COPY Properties: Physical properties REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies(TST6049) ATL-033-02-01 ASTM D 226 2009 PRI Construction Materials Technologies(TST6049) ATL-068-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) ATL-068-02-01 ASTM D 4798 2011(2016) PRI Construction Materials Technologies(TST6049) ATL-068-02-01 TAS 110 2000 PRI Construction Materials Technologies(TST6049) ATL-069-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) ATL-090-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST6049) ATL-149-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) ATL-164-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) BWR-533-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST6049) BWR-543-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) MSA-004-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) MSA-007-02-01 UL 1897 2012 PRI Construction Materials Technologies(TST6049) MSA-026-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) WRMI-011-02-01 ASTM 1970 2015a PRI Construction Materials Technologies(TST6049) MSA-007-02-01 UL 1897 2012 PRI Construction Materials Technologies(TST6049) MSA-030-02-01 ASTM D 1970 2015a UL LLC(TST1740) 02-NK40952 ASTM D 1970 2015a UL LLC(TST1740) 02-NK40952 ASTM D 226 2009 UL LLC(TST1740) 02-NK40952 ASTM D 2626 2004(2012)E1 UL LLC(TST1740) 02-NK40952 ASTM D 4869 2016 UL LLC(TST1740) 02-NK40952 ASTM D 6380 2003(2013) ATL14001.4A FL17322-R4 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ATLAS ROOFING CORPORATION Roofing Underlayments PRODUCT DESCRIPTION #15 Specification Felt ASTM D 226, Type I asphalt saturated organic felt underlayment for use in the HVHZ and non-HVHZ. #30 Organic Saturated Felt ASTM D 4869, Type II asphalt saturated organic felt undedayment for use in the non-HVHZ only. #30 Specification Felt ASTM D 226, Type II asphalt saturated organic felt undedayment for use in the HVHZ and non-HVHZ. #43 Base Sheet ASTM D 2626 asphalt saturated and coated, non-perforated, organic felt underlayment for use in the HVHZ and non-HVHZ. #90 Mineral Surface Roll ASTM D 6380, Class M asphalt-saturated organic roll roofing sheet for use in the Roofing HVHZ and non-HVHZ. Gorilla Guard®EVERFELT 30 Asphalt-saturated organic felt underlayment reinforced with glass fiber that meets the performance requirements of ASTM D 226, Type I for use in the HVHZ and non-HVHZ. Slate/Tile Underlayment ASTM D 6380, Class M asphalt-saturated organic roll roofing sheet for use in the HVHZ and non-HVHZ. WeatherMasterO Ice and ASTM D 1970 SBS modified, self-adhering undedayment reinforced with a Water 100 fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a release film, which is removed during installation. WeatherMaster®Ice and ASTM D 1970 SBS modified, self-adhering undedayment reinforced with a Water 200 fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a split-release film, which is removed during installation. WeatherMaster®Ice and ASTM D 1970 SBS modified, self-adhering underlayment reinforced with a Water 216 fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a split-release film, which is removed during installation. WeatherMaster@ Flexible Ice ASTM D 1970 SBS modified, self-adhering undedayment with plastic film surface and Water for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a split-release film,which is removed during installation. WeatherMaster®Pro-Grade ASTM D 1970 SBS modified, self-adhering underlayment with a fiberglass mat Ice and Water reinforcement and a poly-fabric surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a release film, which is removed during installation. WeatherMaster@ Tile TAS 103 SBS modified, self-adhering undedayment with a fiberglass mat reinforcement and a poly-fabric surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a release film, which is removed during installation. ATL14001.4A FL17322-R4 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61620-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. , ATLAS ROOFING CORPORATION Roofing Underlayments APPLICATION METHOD Installation shall be in accordance with the published manufacturer's installation instructions, the FBC, and the requirements below. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting joints. Exposure of the undedayments shall be limited to a maximum 30 days except as follows: a) #15 Specification Felt, #30 Specification Felt, and #40 Base Sheet —exposure for than 24 hours may adversely affect product performance b) WeatherMaster® Ice and Water 100, WeatherMaster® Ice and Water 200, and WeatherMaster® Ice and Water 216—maximum 30 days c) WeatherMaster® Pro-Grade Ice and Water and WeatherMaster® Flexible Ice and Water—maximum 30 days d) WeatherMaster® Tile—maximum 90 days Self-adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ. Roof coverings shall be mechanically fastened through the underlayment to the roof deck except as follows (or as indicated in other current FBC product approval documents): a) WeatherMaster0 Pro-Grade Ice and Water or WeatherMaster® Tile—ICP Adhesives Polyset AH-160 b) Slate/Tile Underlayment or#90 Mineral Surface Roll Roofing — Convenience Products Touch n' Seal StormBond Roof Tile Adhesive, Dow TileBond, or ICP Adhesives Polyset AH-160 Allowable Roof Coverings: Metal Roof Composite or Wood Asphalt Panels and Photovoltaic Shingles and Slate Clay and Underlayment Shingles Shingles Shingles Shakes Shingles Concrete Tile #15 Specification Felt Y Y Y Y2 Y N #30 Organic Saturated Felt Y Y Y Y Y N #30 Specification Felt Y Y Y Y Y Y #43 Base Sheet Y Y Y N Y Y #90 Mineral Surface Roll Roofing Y' N N N N Y Gorilla Guard®EVERFELT 30 Y Y Y Y, Y N Slate/Tile Underlayment Y' N N N N Y WeatherMasterO Ice and Water Y Y Y N Y N 100 WeatherMaster®Ice and Water Y Y Y N Y N 200 WeatherMasterO Ice and Water Y Y Y N Y N 216 WeatherMasterO Flexible Ice and Y Y Y N Y N Water WeatherMasterO Pro-Grade Ice Y Y Y N Y N and Water WeatherMasterO Tile Y Y Y N Y Y Notes: 1)Open valley applications per 1507.2.9.2 2)Wood shingles only ATL14001.4A FL17322-R4 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. ATLAS ROOFING CORPORATION Roofing Underlayments WIND RESISTANCE(NON-HVHZ ONLY) The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9. Undedavment System No.1 —WeatherMaster®Tile only Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24"o.c. Undedayment: WeatherMaster®Tile shall be fully adhered to the optionally primed plywood deck. Maximum Design -52.5 psf Pressure: LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) Roof slope limitations shall be in accordance with FBC requirements. 3) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) Products described within this report may be used as described in other current FBC product approval documents. 5) Roof coverings shall not be adhered directly to the underlayment unless otherwise approved in this or other current FBC product approval documents. 6) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest P.E. have demonstrated compliance with the Florida Building Code, 6t' Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer. 111%J111111111 �P�Y R. i •pR 2017.09.3 0 •.•\.\G•E•N`S�•FS��i • . 12.44.22 • No 74021 • —04'00' %�' STATE OF :��/� %lo O'��•�� O R t p P' ���` Zachary R. Priest, P.E. A L � Organization FloridaRegistration No. 21 ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation, Zachary R. Priest, P.E.does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT ATL14001AA FI-17322-R4 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not specifically addressed herein.