Product Approval Menu>Product or Application Search> p n Deta
FL# FL14095-R10 FEB 99 2018
Application Type Revision
Code Version 2017 ST. Lucie County, permitting
Application Status Approved
*Approved PR.Approvals by DBPR shall be reviewed and ratified
C and/or the Commission if necessary.
Comments
Archived
Product Manufacturer JELD-WEN FILE COPY
Address/Phone/Email 3737 Lakeport Blvd
Klamath Falls,OR 97601
(800)535-3936
fbcl@jeld-wen.com
Authorized Signature Jason Kantola
fbcl@jeld-wen.com
Technical Representative JELD-WEN Corporate Customer Service
Address/Phone/Email 3737 Lakeport Blvd.
Klamath Falls, OR 97601
(800)535-3936
customerserviceagents@jeld-wen.com
Quality Assurance Representative
Address/Phone/Email
Category Windows
Subcategory Single Hung
Compliance Method Certification Mark or Listing
Certification Agency National Accreditation&Management Institute
Validated By National Accreditation&Management Institute
Referenced Standard and Year(of Standard) Standard Year
TAS 201 1994
TAS 202 1994
TAS 203 1994
Equivalence of Product Standards
Certified By
Product Approval Method Method 1 Option A
Date Submitted 07/11/2017
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=WGEV XQwtDgtGLR%2byCBy... 2/9/2018
Florida Building Code Online Page 2 of 3
Date Validated 07/26/2017
Date Pending FBC Approval
Date Approved 07/28/2017
Summary of Products
FL# Model,Number or Name Description
14095.1 Premium Atlantic Vinyl Single Hung(8100)36"x 72"Insulated Glass(5/16 in PVB
or SGP Lam- 1/8 out Annealed)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL14095 R10 C CAC NI011567.04-R3.odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 04/30/2025
Design Pressure: +65/-70 Installation Instructions
Other: Laminated glazing interlayer material requirements FL14095 R10 II FL14095 R5 II DP65-
meet the current edition of the FBC in accordance with 70 36x72 Impact Installation Instructions.Ddf
Miami-Dade NOA for DuPont SentryGlas and DuPont PVB FL14095 R10 II NI011567.04-R3 Dwgs 07252017,odf
interlayers.White PVC exterior extrusion meet the current Verified By: Hermes Norero, PE 73778
edition of the FBC in accordance with Miami-Dade NOA for Created by Independent Third Party: Yes
Quanex. IG back bedded with Dow 995. Safety glazing Evaluation Reports
required to the exterior at heights above 30 feet. FL14095 R10 AE PER3094.odf
Created by Independent Third Party: Yes
14095.2 Premium Atlantic Vinyl Single Hung (8100)36"x 72"Insulated Glass(1/8 in-1/8
out Annealed)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL14095 R10 C CAC NI011567.08-R1.Ddf
Approved for use outside HVHZ:Yes FL14095 R10 C CAC NI011567.09-R2.pdf
Impact Resistant: No Quality Assurance Contract Expiration Date
Design Pressure: +65/-70 04/30/2025
Other:White PVC exterior extrusion meet the current Installation Instructions
edition of the FBC in accordance with Miami-Dade NOA for FL14095 R10 II NI011567.09-R2 Dwgs 07252017.odf
Quanex. IG back bedded with Dow 995.Safety glazing FL14095 R10 II PAV TSH FBC 36x72 SS 2017-06-26.pdf
required to the exterior at heights above 30 feet. Verified By: Hermes Norero,PE 73778
Created by Independent Third Party: Yes
Evaluation Reports
FL14095 R10 AE PER4869 SS 2017-06-26.Ddf
Created by Independent Third Party: Yes
14095.3 Premium Atlantic Vinyl Single Hung (8100)52 1/8"x 75"Insulated Glass(3/16 in-
3/16 out Annealed)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL14095 R10 C CAC NI011567.06-Rl.Ddf
Approved for use outside HVHZ:Yes FL14095 R10 C CAC NI011567.07-R2.pdf
Impact Resistant: No Quality Assurance Contract Expiration Date
Design Pressure: +65/-70 04/30/2025
Other:White PVC exterior extrusion meet the current Installation Instructions
edition of the FBC in accordance with Miami-Dade NOA for FL14095 R10 II NI011567.07-R2 Dwgs 07252017.Ddf
Quanex. IG back bedded with Dow 995.Windows with FL14095 R10 II PAV TSH FBC 52x75 SS 2017-06-26.pdf
insulated glass wider than 36"require setting blocks. Safety Verified By: Hermes Norero, PE 73778
glazing required to the exterior at heights above 30 feet. Created by Independent Third Party: Yes
Evaluation Reports
FL14095 R10 AE PER4870 SS 2017-06-26.pdf
Created by Independent Third Party: Yes
14095.4 Premium Atlantic Vinyl Single Hung(8100)52 1/8"x 75"Insulated Glass(5/16 in
PVB or SGP Lam- 1/8 out Annealed)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL14095 R10 C CAC NI011567.02-R2.Ddf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 04/30/2025
Design Pressure: +50/-60 Installation Instructions
Other: Laminated glazing interlayer material requirements FL14095 R10 II FL14095 R5 II DP50-
meet the current edition of the FBC in accordance with 60 52.125x75 Impact Installation Instructions.pdf
Miami-Dade NOA for DuPont SentryGlas and DuPont PVB FL14095 R10 II NI011567.02-R2 Dwas 07252017.pdf
interlayers.White PVC exterior extrusion meet the current Verified By: Hermes Norero, PE 73778
edition of the FBC in accordance with Miami-Dade NOA for Created by Independent Third Party: Yes
Quanex. IG back bedded with Dow 995. Windows with Evaluation Reports
insulated glass wider than 36"require setting blocks. Safety FL14095 R10 AE PER3091.pdf
glazing required to the exterior at heights above 30 feet. Created by Independent Third Party: Yes
14095.5 [Premium Atlantic Vinyl Single Hung(8100)52 1/8"x 75"Insulated Glass(5/16 in
SGP Lam-3/16 out Annealed)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL14095 R10 C CAC N1011567.01-Rl.pdf
Approved for use outside HVHZ:Yes FL14095 R10 C CAC NI011567-R1.odf
Impact Resistant:Yes Quality Assurance Contract Expiration Date
Design Pressure: +65/-75 04/30/2025
http://www.floridabui lding.org/pr/pr_app_dtl.aspx?param=wGE VXQwtDgtGLR%2byCBy... 2/9/2018
NOTICE OF PRODUCT CERTIFICATION
\� ,D CERTI
CERTIFICATION NO: NI011567.02-R2
DATE: 05/23/2013
N� 1 CERTIFICATION PROGRAM: Structural
COMPANY: JELD-WEN
CODE: 1822-1
REVISION DATE: 01/13/2017
To verify that the"Notice of Product Certification"is valid,please visit www.NAMICertification.com to assure that the
product is active and currently listed.This certification represents product conformity to the applicable specification and
that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim
certification status. Please review and advise NAMI if any corrections are required to this document.
COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION
JELD-WEN "Premium Atlantic Vinyl Single Hung(8100)"
3737 Lakeport Boulevard Impact Rated Vinyl Single Hung Window
Klamath Falls, OR 97601 (Fin&Flange Installation)
Configuration:O/X
Glazing:IG-1/8"Annealed Glass/Laminate-
1/8"Annealed Glass/0.090"SentryGlas®Plus Interlayer by
DuPont/]/8"Annealed Glass or IG-1/8"Annealed
Glass/Laminate-1/8"Annealed Glass/0.090"PVB by
DuPont/]/8"Annealed Glass
Frame: W-1324mm(52.13") H-1905mm(75")
Sash: W-1254mm(49.38") H-946mm(37.25")
SPECIFICATION PRODUCT RATING
TAS 201/202/203-94 Design Pressure: +50/-60 psf
Large Missile Impact Rated
Product Tested By: National Certified Testing Laboratories
Report No: NCTL-210-3874-1
Expiration Date: April 30,2025
Administrator's Signature:
NATIONAL ACCREDITATION AND
MANAGEMENT INSTITUTE, INC.
4794 George Washington Memorial Highway
Hayes,VA 23072
Tel: (804) 684-5124
Fax: (804) 684-5122
14'D.C.,,,,,I. - THROUGH FRAME
i11R11 JAM
MAX MIN.DISTANCE
FWHI FOR EDGE 3/4" 3 INSTALLATION
CORHM
MIN.
EMBEDMENT
16.3'O.C. 1112"MIN.
WAX'TN6uEMBEDMENT
4AMO 1/4"MAX 1/4"
SHIM SPACE SHIM
MAX
SHIM SPACE
3
zmm �IIfI''Ilpp���+ep
-V
- 2mm
3— 3mm
MIN.DI5TANCE1
tt FOR EDGE:3/4"
GLASS BITE
13 6mm
r
I JAMB SECTION(TYP)
GLAZING DETAIL HORIZONTAL SECTION
FRAME SECTION(TYP)
VERTICAL SECTION
NATE---.i F.-IWmE Opu•rg
1/4"MAX
SHIM SPACE
3
FRONS
2 1112"MIN. PREMIUM ATLANTIC VINYL SH WINDOW
EMBEDMENT Max Frame I OP RATING IMPACT
I. WINDOW WIDTH(SY 1/6'MAX.) I MIN,DISTANCE 52 1/8 x 75 1 +50/-60 1 YES
TYPICAL ELEVATION WITH FASTENER SPACING FOR EDGE:3/4" LARGE MISSILE IMPACT
Installation Notes: General Notes:
1. Seal flange/frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria
2. Use#10 PH or greater fastener though the jamb with sufficient length to penetrate a minimum of 11/2" of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida
into the wood framing. For 2X wood frame substrate(min.S.G.=0.42). Building Code(FBC)including HVHZ and the industry requirement for the stated conditions.
3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 2. All glazing shall conform to ASTM E1300.
to the structure. The host structure is the responsibility of the architect or engineer of record for the 3. At minimum,glazing is 3mm annealed-11 mm airspace-3mm annealed-2mm PVB Interlayer by
project of installation. Addendum to NAMI DuPont-3mm annealed.
Certification No: NI011S67.02-R2 4. Use structural or composite shims where required.
Reviewed By: q"
This schedule addresses only the fasteners required to anchor the Date Reviewed: 07/25/2017
window to achieve the rated design pressure up to the size limitations
noted. It is not intended as a guide to the installation process and does PROJECT ENGINEER: DATE:
F WEN 3737 Lakeport Blvd
not address he sealing consideration that may arise in different wall -- 08/13/2014
conditions. For the complete installation procedure,see the instructions DRAWN BY: SCALE: T Klamath Falls,OR.97601
D.Vezo NTS `� Phone: (800)535-3936
packaged with the window or go to CHECKED BY: TITLE:
www.jeld-wen.com/resources/installation. 1. Kantola
DISCLAIMER: APPROVED BY: Premium Atlantic Vinyl Impact Single Hung Window
.This drawing and its contents are confidential and are not to be PART PRO ECT No,
reproduced or copied in whole or in part or used or disclosed to others �6� 729
except as authorized by JELD-WEN Inc. IDENTIFIER No. PLANT NAME AND LOCATION: CAD DWG.No.: REV: SHEET
1ES1Ep NC71-210-3874- -FBC 001 1 OF 1
NAX NAIL FIN INSTALLATION
IAOY ]
CORNLI6 1/2"MIN.EMBEDMENT
2 2X WOOD FRAME
WDSPAN
MIN.DISTANCE
MIN.DISTANCE
FOR EDGE:3/4" FOR EDGE:3/4'
16.76O.C.
.•THOU 3 2X WOOD
NAIL PIN 1/4"MAX 3
SHIM SPACE '' FRAME
22mm
2— ! 2 1/4"MAX '
3mm 3mm
SHIM SPACE
1112 MIN.
EMBEDMENT
GLASS SITE
13.6mm III
I
GLAZING DETAIL
FRAME SECTION(TYP) JAMB SECTION(TYP)
VERTICAL SECTION HORIZONTAL SECTION
uoTE-CoWM b.,w•.n Noimg Forge 6 wroe opew"g. NOTE:Coulk between Nailing Flange 6 Wood Op-9.
SHIM SPACE 3 -
NIDSPAN 4'MX'
FROM M1N.DISTANCE
C FOR EDGE:3/4" PREMIUM ATLANTIC VINYL SH WINDOW
t 2 2X WOOD FRAME Max FrameI DP RATING IMPACT
WWW pIDTN(as 1/6'MAX.)
11/2"MIN.EMBEDMENT 52 1/8 X 75 +50/-60 7 ES
I
TYPICAL ELEVATION WITH FASTENER SPACING LARGE MI55ILE IMPACT
1
Installation Notes: General Notes:
1. Seal flange/frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria
2. Use#10 PH or greater fastener though the nail fin with sufficient length to penetrate a minimum of 1 of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida
1/2"into the wood framing. For 2X wood frame substrate(min.S.G.=0.42), Building Code(FBC)including HVHZ and the industry requirement for the stated conditions.
3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 2. All glazing shall conform to ASTM E1300.
to the structure. The host structure is the responsibility of the architect or engineer of record for the 3. At minimum,glazing is 3mm annealed-11 mm airspace-3mm annealed-2mm PVB Interlayer by
project of installation. DuPont-3mm annealed.
Digitally signed Hermes F. ,P.E. 4 Use structural or composite shims where required.
Reason:I am approving this documeocument
Date:2014.09.19 16:25:32-04'00'
This schedule addresses only the fasteners required to anchor the ,,y t t I I III,
window to achieve the rated design pressure up to the size limitations ��� "i�
noted. It is not intended as a guide to the installation process and does �� �� PROJECT ENGINEER: DATE:
..••• •• , i 3737 Lakeport Blvd
not address he sealing consideration that may arise in different wall �� Q` •.• �� -- 08/13/2014
conditions. For the complete installation procedure,see the instructions . DRAWN BY: SCALE:
JELDVEN
Klamath Falls,OR.97601
packaged with the window or go to D.Vezo NTS Phone: (541)882-3451
www.jeld-wen.com/resourceslinstallation. CHECKED BY: TITLE:= * * — J. Kantola
"o T T t = APPROVED BY: Premium Atlantic Vinyl Impact Single Hung Window
DISCLAIMER:
This drawing and its contents are confidential and are not to be - �
�,r ••. L P•'• �� PART PRO ECT No
reproduced or copied in whole or in part or used or disclosed to others �i� px. N e � D60 72�
except as authorized by JELD-WEN Inc. 398 to 338 IDENTIFIER
NCTL210'38J4- PFBCNAME AND LOCATION: CAD DWG.No.: REV: oo SHEET 1 OF 3
°•C MAX
TNR.JAW 5.5'MAX. MIN.DISTANCE MASONRY INSTALLATION
FROM FOR EDGE:21/2"
CORNERS
A<d MASONRY ',
2 BLOCK
n a .
11/4"MIN.
18.5'O.C. ° 3 EMBEDMENT
MAX.THRU 4' '
JAMB ' 'I
11/4"MIN.
EMBEDMENT
I/C MAX
SHIM SPACE I/4"MAX
Q 3 SHIM SPACE
MIN,DISTANCE V V '
z2mm FOR EDGE2 1/2" d Q
2mm �
mm 3mm
Q.
t
= GLASS BITE
U mm
i MASONRY
BLOCK
JAMB SECTION(TYP)
AS
GLAZING DETAIL HORIZONTAL SECTION
FRAME 5ECTION(TYP)
VERTICAL SECTION
1/4"MAX
SHIM SPACE
Ir 4.5'FNM
CORNERS .� ' J� EMB/V MIN
EDMENT
4 PREMIUM ATLANTIC VINYL SH WINDOW
Max Frame DP RATING IMPACT
wlwoow rrroTN(sa 1/B•MAx.� I
BLOCK
OOH 52 1/8 x 75 1 +50/-60 1 YES
TYPICAL ELEVATION WITH FASTENER SPACING MIN.DISTANCE
FOR EDGE:21/2" LARGE MISSILE IMPACT
Installation Notes:
General Notes:
1. Seal flange/frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria
2. Use 3/16"ITW Tapcon or equivalent fasteners through frame with sufficient length to penetrate a of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida
minimum of 1 114"into concrete or masonry at each location with a 21/2"min from edge distance.For Building Code(FBC)including HVHZ and the industry requirement for the stated conditions.
concrete (min.fc=3000psi)or masonry substrate(CMU shall adhere to ASTM C90). 2. All glazing shall conform to ASTM E1300.
3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 3. At minimum,glazing is 3mm annealed-11 mm airspace-3mm annealed-2mm PVB Interlayer by
to the structure. The host structure is the responsibility of the architect or engineer of record for the DuPont-3mm annealed.
project of installation. 4. Use structural or composite shims where required.
This schedule addresses only the fasteners required to anchor the
window to achieve the rated design pressure up to the size limitations %
noted. It is not intended as a guide to the installation process and does �� �� PROJECT ENGINEER: DATE:
i 3737 Lakeport Blvd
not address he sealing consideration that may arise in different wall �� @' .••''� �` i� -- 08/13/2014 JEL.WWEN:• Klamath Falls,OR.97601
conditions. For the complete installation procedure,see the instructions .Z` ; DRAWN BY: SCALE:
7
packaged with the window or go to D.Vezo NTS Phone: (541)882-3451
CHECKED BY: TITLE:
www.jeld-wen.com/resources/installation. = * * = J. Kantola
DISCLAIMER: APPROVED BY: Premium Atlantic Vinyl Impact Single Hung Window
441
This drawing and its contents are confidential and are not to be D,n '•. p;•' ��` PART PRO ECT No,
reproduced or copied in whole or in part or used or disclosed to others ��� �%� X60 729
X Noexcept as authorized by JELD-WEN Inc. 398 to 338 IDENTIFIER No. PLANT NAME AND LOCATION: CAD DWG.No.: REV: SHEET
ea NCTI 210-3874- -FBC 00 2 OF 3
14*O*C.MAX' 3.3•MAX. STEEL INSTALLATION
THRU JAMB FROM MIN.DISTANCE
CORNERS 1 FOR EDGE:1/2"
2 "_M,".
thembedment ,,
of ree threads
3 post frame
' 18 gauge min 18(gauge min
MO.O. O.C. Steel Stud
THIIU Steel Stud
JAMB I"..MAX ,
SHIM SPACE 1/4"MAX
SHIM SPACE
22mm MIN.DISTANCE Q
T- zmm FOR EDGE:1/2" �0
3mm 3mm
Min.embedment
In of three threads 3
past frame
GLASS SITE
13 6mm
I 1
GLAZING DETAIL JAMB SECTION(TYP)
FRAME SECTION(TYP) HORIZONTAL SECTION
VERTICAL SECTION
—T-Ca .1-1.-1.,1,—d Wand.,.,
1/4"MAX
SHIM SPACE
FFROM 18 gauge min
CORNERS l 3 Steel Stud PREMIUM ATLANTIC VINYL SH WINDOW
2 Min,embedment
of three threads Max Frame DP RATING IMPACT
p
I
i:::� post from.
52 1/8 x 75 +50/-60 YES
LWINDOW WIDTH(32 1/0'MA%.� I MIN.DISTANCE
TYPICAL El WITH FASTENER SPACING FOR EDGE:112" LARGE MISSILE IMPACT
Installation Notes: General Notes:
1. Seal flange/frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria
2. For anchoring into metal framing use#8 TEK Self Tapping screws with sufficient length to achieve a of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida
minimum embedment of three threads past the frame thickness. Steel substrate min.18ga.,fy=33 ksi. Building Code(FBC)including HVHZ and the industry requirement for the stated conditions.
3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 2• All glazing shall conform to ASTM E1300.
to the structure. The host structure is the responsibility of the architect or engineer of record for the 3. At minimum,glazing is 3mm annealed-11 mm airspace-3mm annealed-2mm PVB Interlayer by
DuPont-3mm annealed.
project of installation. 4. Use structural or composite shims where required.
This schedule addresses only the fasteners required to anchor the
window to achieve the rated design pressure up to the size limitations %
noted. It is not intended as a guide to the installation process and does �� PROJECT ENGINEER: DATE:
not address he sealing consideration that may arise in different wall ��� Q` •.•''••• •• F �i� -- 08/13/2014% JELRWENKlamath3737 Lakeport Blvd
conditions. For the complete installation procedure,see the instructions .r : � % DRAWN BY: scALE: Falls,OR.97601
D.Vezo NTS Phone: (541)882-3451
packaged with the window or go to 7 CHECKED BY: TITLE:
www.jeld-wen.com/resources/installation. _ * * _ 3. Kantola
44/
DISCLAIMER: T T ` APPROVED BY: Premium Atlantic Vinyl Impact Single Hung Window
This drawing and its contents are confidential and are not to be � �,n ••. P:•'•���- PART PRO ECi No
-reproduced or copied in whole or in part or used or disclosed to others ��� ��XlQt.`` C)6� 729
except as authorized by JELD-WEN Inc. 398 338 IDENTIFIER No. PLANT NAME AND LOCATION: GAD DWG.No.: REV: SHEET
ea NCTL210-3874- -FBC 001 3 OF 3