HomeMy WebLinkAboutGAF Architectural Shingle NOA4p.
M I A M lDADE
MIAMI-DADE COUNTV
A an
PRODUCT CONTROL SECTION
DEPARTMEN'T OF RECULATORY AND ECONOMIC RESOURCES tRER) 11805 SW 26 Street. lWoni 208
BOARD A\I) C'()Di.-ADMJfN1STRA,rY0N DMSION11 Miami, Fimida 33175-2474
T (786) 315-2590 F (7M) 315-2599
NOTICE OF ACCEPTANC _(N
E 9�A) v-1 A- --, 0 1 �im i �v, � " c � �m 0 " 1�,
GAIT
I Campus Drive
Pamipp any, NJ 07 054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (A141).
n
This NOA shali not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purKies. If this product or matcrial fails to perform in the accepted manner, the
manufactureriii incur the expense of such testing and the AW may immediately revoke, modify, or suspend the use
ot'such produ-'i or malerial within theirjurisidiction- RER resmes the right to revoke this acceptance, if it is
determined bx M 'anti-Dadc County Product Control Section that this product or material fails to meet the requirements
of the applica!)le building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the =high igh Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Timberline Ultra HDO" Shingles
LABELING. Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
sLitenient: "M iami-Didc County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered alter a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur afier the expiration date or if there has been a revision or change in the
materials, use andior ulantifiacture, of tire: product or process. Misuse of this NOA as an endorsement of any product, for
sales. advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall he cause for termination and reinoval of NOA.
ADVERTISY,',MENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be availtzble for inspection at thejob site at the request of the Building Official -
This NOA ren. ices NOA No. 13-1104.12 and consists of pages I through 5.
The subruitte( documentation was reviewed by Alex Tigera.
NOA No.; 14-1022.21
Expiration Date: 0412VIS
Approval Date; 02/05/15
Page I of 5
ROOFING AsSENMLY APPROVAL
catepzory7
Roofing
Su- I)-Cate2orv:
Asphalt Shingles
Materials-
Laminate
1)eck Type-.
Wood
SCOPE
This apprave,,, GAF Timberline Ultra HD Shingles as manufactured by GAF described in Section 2 of this Notice of
Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test Product Description
Specifications
GAF Timberline Ultra RD 1 -3 )'/,-X 39%
' TAS 110 Fiberglas reinforced ]teary weight asphalt roof
mfanqfaciuritz; shingle, with a laminate profile.
1,xiculions # 1, 2, 3, 4, 5, 6
MANUFACTURING LOCATION
1. Tampa, FT.
2. Michigum City., IN
3. Baltimore, MI)
4. Ennis. -`X
5. Myerstown, PA
6, Tuscaloosa, AL
EVIDENCE SUBMITTED
Test A2enr
Test Identifier
Test NamelRe
Date
Oiderwritcrs i,aboratorics, hw.
ASTM D 3462
02NK41809
11108/02
TAS 107
02N.K4181 1
11/11/01)
TAS 107
03CA3 5209
10/17103
ASTM D.3462.
03NK26444
10/17/03
TAS 107
05CA42840
I Ifl 1/05
TAS 107
05CA47541
05/10/06
ASTM 133462
06CA 10 139
09/13106
TAS 107
PRI Asphalt'lechnolouies, Inc.
TAS 100
ELK -108-02-01
10/14103
TAS 100
ELK -084-02-01
10/30101
TAS 100
F -LK -087-02-01
10/30/02
TAS 100
GAF -046-02-01
04i05/04
TAS 100
GAF -100-02-01
H/16108
ASTM D 3462
GAF -100-01-02
11/16/05
TAS 100
GAF -103-02-01
11/16/05
ASTM D 3462
GAF -103-02-02
11/16/05
tie cc•r�r
NOA No.: 14-1022,21
Expiration Date: 04122/18
Approval Date: 02105/15
Page 2 of 5
LIMITATIONS
I . Fire classification is not part of this ac"ptance', refer to a current Approved Roofing Materials Directory for
Circ niting's ofthis product,
2. Shall not be installed on roof mean heights in excess of 33 ) ft.
3. All products listed herein shall have quality assurance audit in accordance with the Florida Building Code and
Rule 6 IG20-3 of the Florida Administr�iiive Code.
INSTALLATION
I. Shingles shall be installed in compliance with Roofing Application Standard RAS I I D5.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The rianufacturer shall provide clearly written application instructions.
4. Exposure acrd course layout shall be in compliance with Detail'A', attached,
5. Nalli,ilg shall be in compliance with Detail'13% attached.
LABELING
Shingles shat bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of
rnanufacturin ' a fac i I i t\ -.' and following statement: "Miami -Dade County Product Control Approved' or the Miami -Dade
County product Control Sea] as shown below.
BUILDING PE.Rmrr RFQUIREIMENTS:
Application for building permit shall be accompanied by copies of the following-
] . This Notice of Acceptance.
2. A3y other documents required by Building Official or Applicable building code in order to property evaluate the
installation of this material.
iKMUV4H>AMU COUNTY o.-. 14-1022.21
Expiration Date: 04/22/18
Approval Date, 0210-5/15
Page 3 of 5
DETAIL A
COURSE LAYOUT
Exposure
NOA No.: 14-102221
Expiration Date: 04/22/18
Approval Date. 02/05/15
Page 4 of 5
I
131 11 3F,r
4
5-3"6-11
6-1,
4 4
i 1
T
j`w7r.
DETAIL B — 13-14" X 39-3/8"
OVERALL DIMENSIONS AND NAILING PATTERN
39-318"
2 r
6 fasteners 72„ 7 .-.
Front Side (Maximum Slope 21:12)
Tab Sealant
" 211
� riw �rrrr�rrr.■
Back Side
GA FTINIBFRLINE ULTRA HD"'
END OF THIS ACCEPTANCE
Release
Tape
M
1
318"
MIAMii-13j5iIfFCOUNTY NOA No.: 14-1022.21.
o.Expiration Date: 04122%18
Approval Cute: 07/05!15
Page 5 of 5