Loading...
HomeMy WebLinkAboutGAF Architectural Shingle NOA4p. M I A M l­DADE MIAMI-DADE COUNTV A an PRODUCT CONTROL SECTION DEPARTMEN'T OF RECULATORY AND ECONOMIC RESOURCES tRER) 11805 SW 26 Street. lWoni 208 BOARD A\I) C'()Di.-ADMJfN1STRA,rY0N DMSION11 Miami, Fimida 33175-2474 T (786) 315-2590 F (7M) 315-2599 NOTICE OF ACCEPTANC _(N E 9�A) v-1 A- --, 0 1 �im i �v, � " c � �m 0 " 1�, GAIT I Campus Drive Pamipp any, NJ 07 054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (A141). n This NOA shali not be valid after the expiration date stated below. The Miami -Dade County Product Control Section In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purKies. If this product or matcrial fails to perform in the accepted manner, the manufactureriii incur the expense of such testing and the AW may immediately revoke, modify, or suspend the use ot'such produ-'i or malerial within theirjurisidiction- RER resmes the right to revoke this acceptance, if it is determined bx M 'anti-Dadc County Product Control Section that this product or material fails to meet the requirements of the applica!)le building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the =high igh Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Timberline Ultra HDO" Shingles LABELING. Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following sLitenient: "M iami-Didc County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered alter a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur afier the expiration date or if there has been a revision or change in the materials, use andior ulantifiacture, of tire: product or process. Misuse of this NOA as an endorsement of any product, for sales. advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall he cause for termination and reinoval of NOA. ADVERTISY,',MENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be availtzble for inspection at thejob site at the request of the Building Official - This NOA ren. ices NOA No. 13-1104.12 and consists of pages I through 5. The subruitte( documentation was reviewed by Alex Tigera. NOA No.; 14-1022.21 Expiration Date: 0412VIS Approval Date; 02/05/15 Page I of 5 ROOFING AsSENMLY APPROVAL catepzory7 Roofing Su- I)-Cate2orv: Asphalt Shingles Materials- Laminate 1)eck Type-. Wood SCOPE This apprave,,, GAF Timberline Ultra HD Shingles as manufactured by GAF described in Section 2 of this Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications GAF Timberline Ultra RD 1 -3 )'/,-X 39% ' TAS 110 Fiberglas reinforced ]teary weight asphalt roof mfanqfaciuritz; shingle, with a laminate profile. 1,xiculions # 1, 2, 3, 4, 5, 6 MANUFACTURING LOCATION 1. Tampa, FT. 2. Michigum City., IN 3. Baltimore, MI) 4. Ennis. -`X 5. Myerstown, PA 6, Tuscaloosa, AL EVIDENCE SUBMITTED Test A2enr Test Identifier Test NamelRe Date Oiderwritcrs i,aboratorics, hw. ASTM D 3462 02NK41809 11108/02 TAS 107 02N.K4181 1 11/11/01) TAS 107 03CA3 5209 10/17103 ASTM D.3462. 03NK26444 10/17/03 TAS 107 05CA42840 I Ifl 1/05 TAS 107 05CA47541 05/10/06 ASTM 133462 06CA 10 139 09/13106 TAS 107 PRI Asphalt'lechnolouies, Inc. TAS 100 ELK -108-02-01 10/14103 TAS 100 ELK -084-02-01 10/30101 TAS 100 F -LK -087-02-01 10/30/02 TAS 100 GAF -046-02-01 04i05/04 TAS 100 GAF -100-02-01 H/16108 ASTM D 3462 GAF -100-01-02 11/16/05 TAS 100 GAF -103-02-01 11/16/05 ASTM D 3462 GAF -103-02-02 11/16/05 tie cc•r�r NOA No.: 14-1022,21 Expiration Date: 04122/18 Approval Date: 02105/15 Page 2 of 5 LIMITATIONS I . Fire classification is not part of this ac"ptance', refer to a current Approved Roofing Materials Directory for Circ niting's ofthis product, 2. Shall not be installed on roof mean heights in excess of 33 ) ft. 3. All products listed herein shall have quality assurance audit in accordance with the Florida Building Code and Rule 6 IG20-3 of the Florida Administr�iiive Code. INSTALLATION I. Shingles shall be installed in compliance with Roofing Application Standard RAS I I D5. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The rianufacturer shall provide clearly written application instructions. 4. Exposure acrd course layout shall be in compliance with Detail'A', attached, 5. Nalli,ilg shall be in compliance with Detail'13% attached. LABELING Shingles shat bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of rnanufacturin ' a fac i I i t\ -.' and following statement: "Miami -Dade County Product Control Approved' or the Miami -Dade County product Control Sea] as shown below. BUILDING PE.Rmrr RFQUIREIMENTS: Application for building permit shall be accompanied by copies of the following- ] . This Notice of Acceptance. 2. A3y other documents required by Building Official or Applicable building code in order to property evaluate the installation of this material. iKMUV4H>AMU COUNTY o.-. 14-1022.21 Expiration Date: 04/22/18 Approval Date, 0210-5/15 Page 3 of 5 DETAIL A COURSE LAYOUT Exposure NOA No.: 14-102221 Expiration Date: 04/22/18 Approval Date. 02/05/15 Page 4 of 5 I 131 11 3F,r 4 5-3"6-11 6-1, 4 4 i 1 T j`w7r. DETAIL B — 13-14" X 39-3/8" OVERALL DIMENSIONS AND NAILING PATTERN 39-318" 2 r 6 fasteners 72„ 7 .-. Front Side (Maximum Slope 21:12) Tab Sealant " 211 � riw �rrrr�rrr.■ Back Side GA FTINIBFRLINE ULTRA HD"' END OF THIS ACCEPTANCE Release Tape M 1 318" MIAMii-13j5iIfFCOUNTY NOA No.: 14-1022.21. o.Expiration Date: 04122%18 Approval Cute: 07/05!15 Page 5 of 5