Loading...
HomeMy WebLinkAboutProduct Approval 1/19/21018 , Florida Building Code Online � r . 'F, F d _ � A�ttU..:.)q)qY�•Iucf(.r r Y °,,�.tCc yEy r � ,r f� rC� ; xykr r-� x.' �y � 'I �� e�,� � � Yk .yt •_..>.�:,.M.��:Wi.y '6'r ' BCIS Home i Log In I User Registration ; Hot Topics i submit Surcharge I State)&Facts, I Publications i FBC Staff f SC FI rida 11, E f Product Approval ` .+ USER: Public User Product Approval Menu> Product or Application Search>Application List>Application!Detail FL# FL256I-R13 !I;s Application TypeRevision I'' Code Version 2017 Application Status Approved I I I F; Comments it I I Archived I Product'Manufacturer Soprema, Inc.!'I(Canada) Address/Phone/Email 1640 rue Haggarty Drumriiondville, NON-US 00000 (819) 1478-2400 memathieu@soprema-ca Authorized Signature Marc-Etienne,Mathieu memathieu@soprema.ca Technical Representative Marc-Etienne Mathieu Address/Phone/Email 1688 11 'ft Drummondville, NON-US 00000 (819) 478-2400 Ext 3327 memahieu@ tsoprerria.ca I I cif Quality Assurance Representative Jean-Francois Cote, Ph.D. Address/Phone/Email 1640 due Haggarty Drummondville' (888) 811-3145 jfcote@soprer111 ca �' j Category Roofing ' I Subcategory Underllaymentsi II I,I Compliance Method Evaluation Report from a Florida Registered Arc[ 11 Professional Engineer Evaluation,Report- Hardcopy Received Florida Engineer or Architect Name who developed Robert)J. M. Nieminen .the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC I' Quality Assurance Contract Expiration Date11 07/18/2020 f Validated By John W. Knezevich, PE I, I i hffncr//wunu.flnririnhui1einnnrn/nr/nr ann rlHnenv9na -u./2C\/YA..dI1.ellrlCCneLG�nOC.v4114 , II ; 1/19/2018 Florida Building Code Online Validatioli,,Checklist- Hardcopy Received Certificate of Independence FL2569 R13 +COI 2017 01 COI Nieminen pdf Referenced Standard and Year(of Standard) Standard " ASTMD1970,' ASTM D61634 FM 4474 I , FRSA/�[ RI ApCil 2012 (04-12) TAS 110 UL 18197 L'+ Equivalence of Product Standards Certified By Sections from the Code Product Approval Method ' Method 1 Option D Date Submitted 10/09/2017 i. l Date Validated 10/11/2017 Date Pending FBC Approval 10/15%2017 I! Date Approved 12/12%2017 i;I Summary of Products FL# Model, Number or Name Description j I 2569.1 Soprema Roof Self adhering(roof underlayments Underlayments I' I Limits of Use Installation Instructions Approved for use in HVHZ: No FL2569 R13 I II 2017 10 FINAL ER SOPREMA CA UI Approved for use outside HVHZ: Yes R13.pdf I� Impact Resistant: N/A Verified By: Robert Nieminen, P.E. PE-59166 Design Pressure: +N/A/-150 Created by Independent Third Party: Yes Other: 1.) Refer to ER Section 5 for Limits Evaluation Reporti of Use. 2.)The design pressure noted herein FL2569 R13IIAE 2617 10 FINAL ER SOPREMA CA L pertains to underlayment systems used R13.pd beneath adhesive-set tile systems. Refer to Created by Independent Third Party: Yes ER Section 5.6.4 for details. EE idit ' ii Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 I+ 1 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida. ::Privacy Statement::Accessibility State i Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-recor mail to this entity.Instead,contact the office by phone or by traditional 'mall.If youihave any questions,please contact 850.48' 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department w one.The emails provided may be used for official communication with the Ilcensee. However email addresses are public record.If yo address,please provide the Department with an email address which can be made available to,the public.To determine if you are a please click Product Approval Accepts: I°I A 01 OAal�A n10 r TRIN, IT Y ERD Certificate of Authorization #9503 rl I I f� January 1,2417 C � J ' RE: Certification of Independence, Florida F.A.C. Rule 61 G20-3 f To Whom It May Concern: This letter serves to document the following in accordance with Florida F.A.C. Ririe 61 G20-3: I. Exterior Research&Design,LLC.d/b/a Trinity I ERD does not have, na�does,iti intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 1=1 2. Exterior Research& Design, LLC. d/b/a Trinity I ERR is not owned, operated.or controlled by any company manufacturing or distributing products it evaluates. ! 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. I E.are;not,in an F. 5. Building Code Evaluations issued by TrinitylERD and Robert Nieminen, y way,to be construed to mean or imply that TrinityJERD or Robert Nieminen, RE.1 are the Designer of Record for any project on which the Evaluation Report is/was used for permitting or de`,sign guidance unless retained specifically for that purpose on agiven project. Please contact our office with any questions, i 'Sincerely, Robert Nieminen, P.E. Florida Reg.No.59166 �,Vlce President I Email:robertnieminen@trinityerd.com i, I, I TRxN1TVIERD WA: 80 Yester Way,Suite 200 Seattle,WA 98104 P: (206)467-0054 F: (206)267-0272 CT: 353 Christian Street, Unit 13 Oxford,CT 06478 P: (203)262-9245 F: (203)262-9243I pgin p GgUNTY SC: 10 Mauney Court Columbia,SC 29201 P:(803)988-8133 F: (803)988-8111 ACC0E011E0 W1 #%: , HI: 735 Bishop Street,Suite 430 Honolulu,HT 96813 P: (808)535-3144 F: (808)535-3147 wwn,� I � I ; 't i ' li j � E-XTERIOR RESEARCH&DESIGN,I.I.C. 11!Certificote of Authorizotion#9503 353 CHRISTIAN STREET,UNIT#13 ^,-J TRINITY'ERD i rI' OXFORD,CT 06478 (203)262-9245 EVALUATION REPORT Soprema,Inc. Evaluation Report 518010.06.09-1111 1640 rue Haggerty I ! F1.2569-1113 Drummondville,Quebec 12C 5P8 Canada Date ofelssuance:06j1sj2009 (819}478-2400 Revision 21:10/06/2017 SCOPE: i This Evaluation Report is Issued under Rule 61620-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted hasibeen reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code Residential Volume. The products described herein have been evaluated for compliance with the a Eldition (2017) Florida Building Code sections noted herein. DESCRIPTION: Soprema Roof Underlayments ( I' r LABELING: Labeling shall be In accordance with the requirements the Accredited Quality Assurance Agency noted herein. �� ;•i CONTINUED COMPLIANCE:This Evaluation Report is valid until such time as the named products)changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityI ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. i ADVERTISEMENT:The Evaluation Report number preceded by the words "Trinity(ERD Evai'cuated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the,user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of!lthe Building Official. This Evaluation Report consists of pages 1 through 8. ! !' r: Prepared by: 4 Robert1.M.Nieminen,P.E. !,,aA+-,�r'C 'ti0r The facowleseal"appearing was authorized byRobert Nieminen,P.E.oni10/06/2017.This does not serve as an Florida Registration No.59166,Fiorido LICA ANE1983 .; ,�;�o u �;+,+�`k �.t+ eiectrloniwlly signed document. CERTIFICATION OF INDEPENDENCE: i 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial iniilerest inlany company manufacturing or distributingproducts it evaluates. I� ! I 2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. u 131, 3, Robert Nieminen,P.E.does not have nor will acquire,a financial Interest in any company manufacturing or distributing products for which the evaluation repoits are being issued. � 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity invoiv�dl in the approval process of the product. . 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are,in any way,the Designer of Record far any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or,design guidance unless retained specifically for that purpose. i i• 'i J TRINITY ERGS ROOFING COMPONENT EVALUATION: ; 1. SCOPE: Product Categoryi Roofing ?; Sub-Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Soprema, halve derriol strated compliance with the following sections-of the e Edition (2017) Florida Building Code through testing in'accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations''% Conditions of Use set forth herein. � ( iI 2. STANDARDS: Section Property Standard , j Year 1504.3.1 Wind Resistance FM 4474 2011 1504.3.1 Wind Uplift UL 1897 !; 2012 1507.1.1,T1507.1.1,1507.2.9.2 Physical Properties ASTM Di1970 j 2015 1507.3.3 Physical Properties FRSA/TRI April 2022 2012 FRSA/TRI April 2012(04-12) Physical Properties ASTM D6163 !'i f 2008 TAS 110 Accelerated Weathering TAS 110+ i' ! 2000 3. REFERENCES: ! ,j Entity Examination Reference !!I Date ERD(TST6049) ASTM D1970/TAS 110 2968.05 04-2 05/14/2004 ERD(TST6049) Physical Properties 2757.0ios j,!f 02/03/2005 ERD(TST6049) ASTM D1970/TAS 110 2974.03!05-2 05/17/2005 ERD(TST6049) Wind Resistance 2778.07'05 f 07/15/2005 ERD(TST6049) Wind Resistance 2779.1105-R1 04/18/2007 ERD(TST6049) TAS 103/TAS 110 S7120.11.07-2 ! I 11/02/2007 ERD(TST6049) ASTM D1970/TAS 110 S13190.62.09-R1 I I 04/01/2010 ERD(TST6049) ASTM D1970/TAS 110 531370.03.10-1-R1; 04/07/2010 ERD(TST6049) Physical Properties./Tensile Adhesion S11150.05.10-Rill;1 09/09/2010 ERD(TST6049) Physical Properties/Tensile Adhesion S11150.0,5.09-R2i': 10/05/2010 i ERD(TST6049) ASTM D1970 S37210.11.11 ;i! 11/09/2011 ERD(TST6049) ASTM D1970 S40540.02'13-1 { 02/19/2013 ERD(TST6049) Physical Properties/Tensile Adhesion 543530.02.14-1 ';;' 02/21/2014 ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-S6,645.02.19 02/1.3/2015 ERD(TST6049) Accelerated Weathering SOPC-SC8520.14 1 ) 04/17/2015 ERD(TST6049) Wind Resistance SOPC-SC14045.05;17-R1 06/07/2017 M-D(CER1592) HVHZ Compliance 15-0508."64 ;; 09/24/2015 ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 (( 03/01/2017 PRI(TST5878). Physical Properties SOP-06402-01 i l i 12/03/2013 Soprema,Inc.(PDM3511) Equivalency Declaration 5A SMOOTH PLY 40' 06/29/2015 UL,LLC(QUA9625) Quality Control Service Confirmation Exp.07/18/2020 4. PRODUCT DESCRIPTION: 4.1 Lastobond TU HT Is a self-adhering, non-woven polyester fabric surfaced;i ISBS modified bitumen roof underlayment;meets ASTM D1970 and FRSA/TRI April 2012(04-12). ! 4.2 Lastobond Shield is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths;36 and 45 inch;meets ASTM D2970. 4.3 RESISTO SA SMOOTH PLY 40 Is a self-adhering,woven polyethylene surfaced;SBS modified bitumen roof underlayment;available in 3.3 ft x 65 ft rolls;meets ASTM D1970. ;! 4.4 Lastobond Shield HT Is a self-adhering, woven polyethylene surfaclled, high temperature, SBS modified bitumen roof underlayment;meets ASTM D1970. 'l I Exterior Research and Design,I.I.C. ( Evaluation Report S18010.06.09-R11 CertgfarteofAuthodzoHon#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION ". FL2569-R13 Soprema,Inc. Revision 11:10/06/2017 Page 2 of 8 i" I ��i 4.5 Lastobond Pro HT-N is a self-adhering, woven polyethylene surfaced;>SBS modified bitumen roof underlayment available In two widths;36 and 45 inch;meets ASTM D1970. 4.6 Lastobond Pro HT-S is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment;meets ASTM D1970. 4.7 Lastobond 195 is a self-adhering, glass-mat reinforced, sand-s'rfaced,•',SBS modified bitumen roof underlayment,meets ASTM D1970. 4.8 Lastobond Eaves Protection Sheet is a self-adhering, glass-mat rein forced, 'sand-surfaced, SBS modified bitumen roof underiayment;meets ASTM D1970. �I 4.9 Lastobond Eco is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment;meets ASTM D1970. 4.10 Lastobond Smooth Seal HT Is a self-adhering,glass-mat reinforced!film-surfaced, 5BS modified bitumen roof underlayment;meets ASTM D1970. !� 4.11 RESISTO L81236 is a self-adhering, glass-mat reinforced, sand-surfaced,'SBS modified bitumen roof underlayment,with a 36-inch shut width,Mots ASTM a1i 4.12 PrimeSource Grip-Rite Eave&Valley Protector is a self-adhering,gla�,ss-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment,with a 36-inch sheet width;meets ASTM D1970. 4.13 RESISTO LB1244 is a self-adhering, glass-mat reinforced, sand-surtaced, SBS modified bitumen roof underlayment,with a 44-inch sheet width;meets ASTM D1970. l) 4.14 Colphene FR GR is a self-adhering, fiberglass reinforced, granule-surfaced,' SBS modified bitumen roof underlayment;meets ASTM D1970 and FRSA/TRI April 2012(04-12). j S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity)ERD nor Robert INieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,Jior previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this report; refer to current Approved]Roofing!Materials Directory for fire ratings of this product. 5.4 Soprema Roof Underlayments may be used with any prepared roof c Ever where the product is specifically referenced within FBC approval documents. If not listed,a request may be made to'the Authority Having Jurisdiction for approval based on this evaluation combined with supporting'data for the prepared roof covering. 5.5 Allowable Roof Covers: ! 7 AaIE 1;,ROOF Co\tER OPTIONS I VIA Asphalt Nall-On Foam-On Wood Shakes& Underlayment Metal'• Slate Shingles Tile Tile Shingles Yes YesYes'- Lastobond TU HT Yes` ' Yes See 5.5,1' Yes Lastobond Shield J Pro HT-N J RESlSTO SA r`Yes Ab. No No ' x Yes Yes SMOOTH PLY 40 yes 'No, No Yesi,l -Yes Yes. Lastobond Shield HT/Pro HT-S }- -77 Lastobond Eaves Protection Sheet j YeS No No. 1' No {Fih i Yes Yes Lastobond 195 Lastobond ECO j RESiSTO L81236,Grip- �!{ ' Rite Ea Rite &Va{ley Protector/RESISTO Yes IVo Na Noa; Yes Yes LB1244 � I Ev'aluationReportS18010.06.09-R31 p I i F�2.569d113 Revlslon 11:10106)2017 terti(Icute of Authorisation#9st>3 6�ED1Z10N�201°iSoBPCM�Nnc H2EV AIUAT\QN Page 3 of fi d ERD i •�"v � �6 'I i It j 5.6.4.2 For mechanically attached Base Sheet,the maximum design pressure for the!selected assembly shall meet or exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A. Alternatively, the maximum design pressure for the selected assembly shaft meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In thin case, Zolnes 2'and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDi, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. 5.7 Exposure Limitations:. Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond Eco Lastobond Smooth Seal HT, RESISTO LBi236,Grip-Rite Eave&Valley Protector or RESiSTO LB1244 shalllinot be left exposed for longer than 30- days after installation. Lastobond Shield,Lastobond Pro HT-N,RESiSTO SA SMOOTH PLY X40,Lastobond Shield HT or Lastobond Pro HT-S shall not be left exposed for longer than 90-days after installation.I': Lastobond TU HT or Colphene FR GR shall not be left exposed for lo nger tha in 180-days after Installation, 5.8 Tile Slippage Limitations(TAS 103 per FRSA/TRI April 2012(04-12)).- When 04-12));When loading roof tiles on the underlayment in direct-deck the assemblies,Athe maximum.roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. I 4 TABLE 2'TILE SIIFAAGE LIMITATIONS FOR I*EG,T-".DECK TjLEIINSTAILI 1 N5 Underlayment Tice Profile Stlaging Method Maximum l! Slope Flat Max.10-til4ikack t 6:12 Lugged Max.10-tile stack ; 5:12 Max.10•tilelstack(bottom 2-tile stack shall be inverted,followed by 8 tiles high 6:12 on slope,as shown below) Lastobond TU HT K. Lugged rs, Y }� 11 Fol phene FR GR Flat Max.10-til hack 5:12 Lugged Max.10-tilel stack 6:12 Exterior Research and Design,I.I.C. i 6valuat6 Report 518010.46,09-R31 Cert¢IcateofAuthor&adon#9503 6TM EDITION(2017)FBC NON-HVHZ EVALUATION i, FL2569-R13 Soprema,Inc. Revision 11:10/06/2017 Page 6 of a i,I