Loading...
HomeMy WebLinkAboutProduct Approval Busfiness • Professional Regulation 8CIS Home Log In ' User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links Search bprProduct Approval USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail RECEIVED • + FL# FL10674-R13 Application Type Revision , 'j1$ Code Version 2017 FEB 00 D Application Status Approved ST. Lucie County, Permitting Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo,OH 43659 (419) 376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert J.M. Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 05/16/2020 Validated By John W. Knezevich, PE Validation Checklist-Hardcopy Received Certificate of Independence FL10674 R13 COI 2017 01 COI Nieminen odf Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2011 Equivalence of Product Standards Certified By Sections from the Code https:Nwww.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V°/p2boQT%2b6w7ahReglCQ8ucR6ixEBFhs7tvJgZew%3d%3d 112 TRINITY ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated compliance with the following sections of the a Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: gntitt Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme®are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 Devonshire'are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration, TruDefinition Duration, Duration* Premium Cool, TruDefinition* Duration Designer Color Collection, TruDefinition Oakridge*, Oakridge® and WeatherGuard' HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Hip&Ridge Shingles: 4.2.1 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard* HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidge"m Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Accessory Starter Strips: 4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-RS Certiftwate of Authorization iJ9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1313 Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017 Page 2 of 8 TRINITY ERD 5.4 Wind Classification: 5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable for use in all wind zones up to Vasil = 150 mph (V„It = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vasd=150 mph(Vuit= 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3. 6. INSTALLATION: 6_1 Underlavment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shinales: 6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Berkshires shingles require minimum five(5)nails per shingle. ➢ WeatherGuard*HP shingles require minimum six(6)nails per shingle. ➢ Devonshirem shingles require minimum six(6)nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing–Starter Strip Shingle and Starter Strip Plus: Feh underlayment Deck Felt una.rrym.rd Dock SeR+dr WeathsrLoclakE Sell.ad Bred urrdsdernant WesdwwLocke underlayment Drip— r— Drip edge DripDrroedge 9e Nails locatedlocated2"-3"from eave r-r hom save Install first Self-sealing adhesive Ssrpq edMsivs StarterStriP positioned along eave k*dfirst SwwStrip Pln P + gam shingle with ` with 8"removed 6"removed Starter Strip shingle overhangs eaves and rakes'i'-'-y' Stow Strip Pku overhangs saves and rakes 1!4^-3/4" Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8 certificate of Authorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017 Page 3 of 8 TRINITY ERS 6.2.6 Minimum Nailing–Classic®&Supreme: Fr Mansard or Area para Normal Mansard or Area pare s High Wind desvenes y Wind Areas High Wind desvarres y vientos normales Areas vientos fuertss Area pare vierrtos norms/es Areas vientos fuertes �"� 12t Ul e 5 518"Exposure idn Exposicidn 6.2.7 Minimum Nailing–Berkshire®: Sealant strip Sealant strip La tira de seCador La Lira de sellador t— �t—i•�---s • i--s • —s• • • —. • • • • 8 Y2" 9 Vt' 9 y:'• 8 yr 8 i,Z" 8�.h,1 8 ty� Lj r r r Standard Fastening Pattern 6-Nail Fastening Pattern Sealant strip La tira de seflador ••--i• ----------- • e.---------- 11f 81%C A V:" 8 1/21" r 2 Asphalt rooting ptnorit Cefnento de techo de astaito Mansard or Steep Slope Fastening Pattern Exterior Research and Design,LLC. Evaluation Report 037940.02.12-Rg Certljkate oJAuthorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017 Page 4 of 8 TRINITY ERa 6.2.8 Minimum Nailing—Devonshire''": —e( 1r+ 8n $n 7" No a,�o1 Nails 5-518"exposure . Sealant location Exposicitin de 5.5/8 pulp U6icacion del seilador Ten t"Spots of Asphalt Roof Cement Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinitiona Duration•Designer Color Collection: 4-Nail Fastening Pattern 6-Nail Fastening Pattern luaNaiOtasoemng area width LnNai9 fastening area Width Not,lyp.Wl Nail,7ypca1 1-1 12^ 12- 1^ 1' 12" 0--C—e.wd • sa.n a.r • r�a:wr'T�- _ o...- _. a..e..a`..:�a_S"_._�.. 67lS"i3/a^ E1/S"bol•" seew Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for Slopes Greater Than 27:12 S—Nail,lase—li ere.wWN H.H.ryFKn 7" tr• 12' i-ta••ssra- F—1"S"M Aspen Roofing torrent Mansard or Steep Slope Fastening Pattern Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-118 Certificate of Authorization#9503 6TH EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113 Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017 Page 5 of 8 TRINITY ERS 6_3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire* Hip and Ridge Shingles, High Ridge, WeatherGuarde HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using four (4) nails per shingle. Installation of DuraRidgeT"" Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge: Fig.1 4 Fig.2 F.— PrewaWlg Yliltl Direction p TopVlew SideMew 4 A Naas Nyle 1 1 N71 Top lat place etl T Place 1 I p I I I 1 i i p i i I 1 I I I I A 1 1 V Y �I--'--.I Elpostre �i I I I i I I 6.3.4 Minimum Nailing—WeatherGuard®HP Hip and Ridge: Fig.A q e Fig.C Hip&Ridge Shingle Fastening Pnwalling Wild Top Vlew Orrectbn p A Nails — —�.�44 I 1 A i i Nails NaIM p I I OXT, A I I I I S' 17 Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8 Certificate ofAuthori:ation#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017 Page 7 of 8 TRINITY ERS 6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles: Prevailing Standard —11 Wind Direction sosbwt strip Pattern ng T— 6'Exposure 12' Sealant Futon 7'h' 7'h 6• posutro Cover Exposed j+ Fasteners with Roof Cement I• 12' 6.3.6 Minimum Nailing—DuraRidgel Hip&Ridge Shingles: Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. Pra+aiinq Mind Diracocn Top view �—D�raaian domimnta du rant Vue on pl- Diwoon dal'iwvw prodotmmme II- Visa superior I•I C$.0 81 �` •� i i l I� 1 l + + °I• slag $' 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(631)546-2458; Kanchi.Agrawala-Dokania@ul.com - END OF EVALUATION REPORT- Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113 Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017 Page 8 of 8