HomeMy WebLinkAboutProduct Approval Business
& Professional
BCIS Home Log In User Registration Hot Topic Submit Surcharge Stats&Fads Publications FBC Staff BCIS Site Map Links Search
'da
3 Product Approval
i USER:Public User p r
Product Approval Menu>Product or Applicatlon Search>Application List>Application Detail
+ FL# FL10674-R13
Application Type Revision
Code Version 2017
Application Status Approved RECEIVED
Comments G FFB " 0 '-,,018 018
Archived r D J v
Product Manufacturer Owens Corning I ST. Lucie County, Permitting
Address/Phone/Email One Owens Corning Parkway
Toledo,OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo,OH 43659
(419)376-8360
` mel.sancrant@owenscornig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
LU Professional Engineer
JEvaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert J.M. Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 05/16/2020
Validated By John W. Knezevich, PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL10674 R13 COI 2017 01 COI Nieminen.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2016
ASTM D3462 2010
ASTM D7158 2011
Equivalence of Product Standards
Certified By
Sections from the Code
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param--wGEVXQwtDgtBNbEY5V°/p2boQT%2b6w7ahReglCQ8ucR6ixEBFhs7tvJgZew%3d%3d 112
TRINITY ERS
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning,have demonstrated
compliance with the following sections of the I`h Edition (2017) Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011
3. REFERENCES:
gnfity Examination Reference Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic and Supreme®are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 DevonshireTM are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 Duration, TruDefinition Duration, Duration Premium Cool, TruDefinition Duration* Designer Color
Collection, TruDefinition*Oakridge, Oakridge and WeatherGuard* HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Hip&Ridge Shingles:
4.2.1 Berkshire' Hip & Ridge Shingles, High Ridge, WeatherGuard' HP Hip & Ridge Shingles, ProEdge Hip & Ridge
Shingles and DuraRidgelm Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
4.3 Accessory Starter Strips:
4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design,U.C. Evaluation Report 037940.02.12-118
CerWwWe of Authorization#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 2 of 8
TRINITY ERS
5.4 Wind Classification:
5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable
for use in all wind zones up to Vasd = 150 mph (V„It = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F, indicating the
shingles are acceptable for use in all wind zones up to Vasd=150 mph(V„It= 194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean
roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3.
6.2 Asphalt Shinizies:
6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following
exceptions:
➢ Berkshires shingles require minimum five(5)nails per shingle.
➢ WeatherGuard*HP shingles require minimum six(6)nails per shingle.
➢ Devonshire'shingles require minimum six(6)nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus:
Felt underlayment Deck Fek underlayment Deck SeHedhered
weathercock
SeWadhered underlayment
WeatherLock'
underlaynient p
Drip, `- Drip edge
edge Drip edge Dnp—
edge
Nails located Nails touted
2"-3"from eave 2`-3-from cave
Install first SeH-sealing adhesive Sep-ssakng adhesive
Starter Strip positioned along eave Instal first Starter Strip Plus positioned along eave
shingle with with F removed--- �
6"removed
Starter Strip shingle overhangs eaves and rakes!i'-3i' Starter Strip Plus overhangs eaves and rakes 1A-3!4"
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certificate of Authorization#9503 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 3 of 8
TRINITY ERS
6.2.6 Minimum Nailing—Classic®&Supreme:
Normal Mansard or At"pare Normal Mansard or Area pare
Wind Areas High Wind desvanei y Wind Areas High Wind desvones y
Area pare vientos norma/es Areas vientos fuertes Area pare vientos normals Areas vientos fuertes
t' iAlt.. t. z. i6 z. t. �tz.. IA) t' t' z' lB) rz' t' �
t tr =- t
•�. t .
5"Exposure 6 5/8"Exposure
Exposicidn
Exposici6n
6.2.7 Minimum Nailing—Berkshire®:
Sealant strip Sealant strip
La tira de seNdor La tira de sellador
7.8 b:" v.�,
LUJ2�
g t:Z g t�
1.
Standard Fastening Pattern 6-Nail Fastening Pattern
Sealant strip
La tva de seltedor
• --s
04----------*• • -►•�--►•
�t..8 1'2' 8 tib' 81/27 8 t/y'
t"
r
2 Asphalt roofing cement
Cemento de techo de asta7to
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8
Certificate ojAuthorizatlon#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 4 of 8
i
TRINITY ERS
6.2.8 Minimum Nailing—Devonshire—:
1_ 1?„ 8„ $„ $n 7" 1
gown
Nails
.. r - e
Wil"exposure Sealant location -
Exposicibn de 5"518 pulp Ubicaci6n del seilador
Ten 1"Spots of Asphah Roof Cement
Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing — Duration®, Tru Definition® Duration, Duration® Premium Cool & TruDefinition"
Duration Designer Color Collection:
4-Nail Fastening Pattern 6-Nail Fastening Pattern
SprenalO hstem,p aea wish svWs®fa WWV a•a width
N>I,rypiW hill lyplp1
iz-
t^ Lz^ Lr t^ > � Lr 1^
s.m a..,.l •. nw.-o own w.e. •F1 F�
circ"srre^ star•s sn"
17 F� j
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening for Slopes Greater Than 21:12
SmaladO Heaang ena width
NO Typlul
Fr
ave^san"
— r
roar r"spa+a AeWurt eoamg eem.nt
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8
Certificate of Authorization#9503 6r"EDITION(2017)FBC NON-HVH2 EVALUATION FL10674-R13
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 5 of 8
TRINITY ERD
6.3 Hip&Ridge Shingles:
6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard• HP Hip and Ridge Shingles
and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions,
using four (4) nails per shingle. Installation of DuraRidgel Hip & Ridge Shingles shall comply with the
Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning
published information on wind resistance and installation limitations, including the use of hand-sealing for
wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge:
Fig.1 4 Fig.2
t— lomwamrownaDirectionA roawcw sideman
A Nais Naik
"as- 09
04 � z TOP Lanblaled r 7
Place
1 1
4 I I I
�
it ffiI
1
EIpo9lae I
I
I
1 I
I
I
6.3.4 Minimum Nailing—WeatherGuard•HP Hip and Ridge:
Fig.C Hip&Ridge Shingle Fastening
Fig.A Topv ev,
P-311ing TAnd
�—Dlreclbn
Nalls
A I I Noir Nur
A I I r
r. z,.
p I 1
I I I I
'I
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8
Certif tate ofAuthorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 7 of 8
TRINITY ERS
6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles:
Prevailing Standard 1f°
Wind DirectionFastening
Salent Strip . Pattern
�--� 6•Exposure r.1 r
Faetex 716' 71 g•Expesure
Cewr Exposed1
Fasteners with
Reef Cement
6.3.6 Minimum Nailing—DuraRidgel Hip&Ridge Shingles:
Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
Pr"rrfne
Wind Dt Toy Vwt
''—D'naisndomp�"c•du.•nc VW""nM
Dir•cdond•I+iwwpredwn"n * IVbungenor II
.2_ T w
SIC
r^ Ck
• Owwt tonbq SrwNai° • u10
I`
mask
• l l i i
V IJ�G
} II
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(631)546-2458; Kanchi.Agrawala-Dokania@ul.com
- END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certificate of Authorization X9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 8 of 8