HomeMy WebLinkAboutProduct Approval BCIS Home Log In i User Registration Hot Topic Submit Surcharge I Stats&Facts:u Publications I FBC Staff i BCIS Site Map
bProduct
Approval
USER:Public User r
Product Approval Menu>Product or Application Search>Application Ll st>Application Detail i
II !
bD i. FL# FL2569-1113;
Application Type Revision I Ii
Code Version 2017
Application Status Approved
� I
Comments
Archived r
Product Manufacturer Soprema,Inc. (Canada.)
Address/Phone/Email 1640 rue Haggarty I11 -
Drummondville, NON-US 00000
(819)478-2400
memathieu @soprema.ca
Authorized Signature Marc-Etienne Mathieu
.memathieu@soprema.ca
Technical Representative Marc-Etienne Mathieu
Address/Phone/Email 1688 Jean-Berchmans-Michaud
Drummondville, NON-US 00000
(819)478-2400 Ext 3327
memathieu@soprema.ca ,!
Quality Assurance Representative Jean-Francois Cote;iPh.D. ,
Address/Phone/Email 1640 rue Haggartyj
Drummondville !'
(888) 811-3145
jfcote@sop�ema.ca'.
Category Roofing i
Subcategory Underlayments
Compliance Method Evaluation(Report from a Florida Registered Architect or a
Professional Engineer
Evaluation Report-Hardcopy Received
i
Florida Engineer or Architect Name who developed Robert J. M. Niemi''en !
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 07/18/2020
Validated By John W. Knezevich PE
a6 Validation Checklist- Hardcopy Received
I
Certificate of Independence FL2569 R13 COI :2017 01 COI Nieminen.odf
Referenced Standard and Year(of Standard) Standard
ASTM D1970
ASTM D6163
FM 4474
FRSA/TRI April 2012 (04-12)
TAS 110
UL 1897
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/09/2017
Date Validated 10/11/2017
Date Pending FBC Approval 10/15/2017
Date Approved 12/12/2017
Summary of Products
FL# Model,Number or Name Description
2569.1 Soprema Roof Self adhering roof underlayments
Underlayments
Limits of Use Installation Instructions
I Approved for use in HVHZ: No FL2569 R13 II 2017 10 FINAL ER SOPREMA CA UNDERLAY
Approved for use outside HVHZ:Yes R13.pdf
Impact Resistant: N/A Verified By: Robert Nieminen, P.E. PE-59166
Design Pressure: +N/A/-150 Created by Independent Third Party: Yes
Other: 1.) Refer to ER Section 5 for Limits Evaluation Reports
of Use. 2.)The design pressure noted herein FL2569 R13 AE 2017 10 FINAL ER SOPREMA CA UNDERLA`
pertains to underlayment systems used R13.pdf
I beneath adhesive-set tile systems. Refer to Created by Independent Third Party: Yes
ER Section 5.6.4 for details.
Back Pfext
Contact Us::.2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Ref
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pu
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wis
address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee un(
please click here.
Product Approval Accepts:
ftc. ® RE M
Credit.Card.
,safe
� i n
A, I
EXTERIOR RESEARCH&DESIGN,I.I.C.
R ;Certificate of Authorization#9503
TRiN�TY�ERD 3,53 CHRISTIAN STREET,UNIT#13 "
`;' I; OXFORD,CT 06478
(203)262-9245
EVALUATION REPORT
Soprema,Inc. II Evaluation Report 518010.06.09-1111
1640 rue Haggerty FL2569-1113
Drummondville,Quebec J2C 5P8 Canada Date of Issuance:06/15/2009
(819)478-2400 ! " Revision 11:10/06/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules,land regulations governing the use of
I
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for,use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6"' Editionl(2017) Florida Building Code
sections noted herein. '
DESCRIPTION: Soprema Roof Underlayments I� i
LABELING,: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named products)changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate)to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notifyilRoberti ieminen, P.E. if the product
changes;or the referenced Quality Assurance documentation changes. Trinity I ERD requires a;lcomplete review of this
Evaluation Report relative to updated Code requirements with each Code Cycler p
1I l,l,
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IDO Evaluatedu may be displayed in
advertising literature. If any portion of the Evaluation Report its displayed,then it shall.be done in its entirety.
INSPECTION:.Upon request,a copy of this entire Evaluation Report shall be provided to the user,by the manufacturer or
its distributors and shall be available for inspection at the job site at the reque4of the Building Official.
This Evaluation Report consists of pages 1 through 8.
SI
Prepared by: '
I u�Ca-5?1§3J' II I
Robert J.M.Nieminen,P.E. ''.`QC's;°,' iO :" The facsimile'seal appearing was authorized by Robert
Zi.
Florida Registration No.59166,Florida DC4ANE1983
Nieminen,P.E:on 10/d6/2017.This does not serve as an
a electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates. it ' I II.
2. Trini,tyl ERD is not owned,operated or controlled by any company manufacturing or distributing productsjit evaluates.
3. Robert Nieminen,-P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
f which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other,entity in lolved in-the approval process of the
product. ;
5. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are; in any way,the'Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting',;or design guidance unless retained
specifically for that purpose. :I
I
\1J TRINITY I ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the
following sections of the 6"' Edition (2017) Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind Resistance FM 4474 2011
1504.3.1 Wind Uplift UL 1897 2012
1507.1.1,T1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015
1507.3.3 Physical Properties FRSA/TRI April 2012 2012
FRSA/TRI April 2012(04-12) Physical Properties ASTM D6163 2008
TAS 110 Accelerated Weathering TAS 110 2000
3. REFERENCES:
gniigy Examination Reference Date
ERD(TST6049) ASTM D1970/TAS 110 2968.05.04-2 05/14/2004
ERD(TST6049) Physical Properties 2757.02.05 02/03/2005
ERD(TST6049) ASTM D1970/TAS 110 2974.03.05-2 05/17/2005
ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005
ERD(TST6049) Wind Resistance 2779.11.05-111 04/18/2007
ERD(TST6049) TAS 103/TAS 110 57120.11.07-2 11/02/2007
ERD(TST6049) ASTM D1970/TAS 110 513190.02.09-111 04/01/2010
ERD(TST6049) ASTM D1970/TAS 110 531370.03.10-1-R1 04/07/2010
ERD(TST6049) Physical Properties/Tensile Adhesion S11150.05.10-R1 09/09/2010
ERD(TST6049) Physical Properties/Tensile Adhesion S11150.05.09-112 10/05/2010
ERD(TST6049) ASTM D1970 S37210.11.11 11/09/2011
ERD(TST6049) ASTM D1970 540540.02.13-1 02/19/2013
ERD(TST6049) Physical Properties/Tensile Adhesion 543530.02.14-1 02/21/2014
ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SOPC-SC8520.14 04/17/2015
ERD(TST6049) Wind Resistance SOPC-SC14045.05.17-R1 06/07/2017
M-D(CER1592) HVHZ Compliance 15-0508.04 09/24/2015
ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017
PRI(TST5878) Physical Properties SOP-06402-01 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015
UL,LLC(QUA9625) Quality Control Service Confirmation Exp.07/18/2020
4. PRODUCT DESCRIPTION:
4.1 Lastobond TU HT is a self-adhering, non-woven polyester fabric surfaced, SBS modified bitumen roof
underlayment;meets ASTM D1970 and FRSA/TRI April 2012(04-12).
4.2 Lastobond Shield is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment available in two widths;36 and 45 inch;meets ASTM D1970.
4.3 RESISTO SA SMOOTH PLY 40 is a self-adhering,woven polyethylene surfaced, SBS modified bitumen roof
underlayment;available in 3.3 ft x 65 ft rolls;meets ASTM D1970.
4.4 Lastobond Shield HT is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified
bitumen roof underlayment;meets ASTM D1970.
Exterior Research and Design,U.C. Evaluation Report S18010.06.09-1111
Certificate of Authorization 119503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION F1.2569-1113
Soprema,Inc. Revision 11:10/06/2017
Page 2 of 8
TRINITY I ERD
4:5 Lastobond Pro HT-N is a self-adhering, woven polyethylene surfaced; SBS modified bitumen roof
underlayment available in two widths;36 and 45 inch;meets ASTMD1970.�I,+
i
4.6 Lastobond Pro HT-5 is a self-adhering, woven polyethylene surfaced, high to Iperature, SBS modified
bitumen roof underlayment;meets ASTM D1970.
4:7 Lastobond 195 is a self-adhering, glass-mat reinforced, sand;surfaced; SBS ''modified bitumen roof
underlayment;meets ASTM D1970.
4.8 Lastobond Eaves Protection Sheet is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified
bitumen roof underlayment;meets ASTM D1970.
4.9 Lastobond Eco is a self-adhering, glass-mat reinforced, sand-surfaced;! SBS ,,modified bitumen roof
underlayment;meets ASTM D1970.
4.10 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced, film-surfaced, SBS modified bitumen
roof underlayment;meets ASTM D1970.
4.11 RESISTO LB1236 is a self-adhering, glass-mat reinforced, sand-surface•d, SBS modified bitumen roof
underlayment,with a 36-inch sheet width;meets ASTM D1970. i'
4.12 PrimeSource Grip-Rite Eave&Valley Protector is a self-adhering,glass-matlreinforced,sand-surfaced,SBS
I modified bitumen roof underlayment,with a 36-inch sheet width;meets ASTM D1970.
4.13 RESISTO LB1244 is a self-adhering, glass-mat reinforced, sand±surfaced, SBS l modified bitumen roof
underlayment,"with a 44-inch sheet width;meets ASTM D1970.
4.14 Colphene FR GR is a self-adhering, fiberglass reinforced, granule-surfa e, SBS modified bitumen roof
underlayment;meets ASTM D1970 and FRSA/TRI April 2012(04-12). I
5. LIMITATIONS: I
5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E..are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous,versions thereof, is/was
used for permitting or design guidance unless retained specifically for thatjpurpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. I
5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Soprema Roof Underlayments may be used with any prepared ro'I f cover where the product is specifically
referenced within FBC approval 'documents. If not"listed, a request may be made to the Authority Having
Jurisdiction for approval-based on this evaluation combined with suppotAing data for the prepared roof
covering.
5.5 Allowable Roof Covers: ill
;I
TABLE 1 ROOF COVER OPTIONS fI
Asphalt Nail-On Foam-dn ± Wood Shakes&
Underlayment I Metal Slate
Shingles Tile Tile Shingles
Lastobond TU HT ..Yes Yes; Yes ! Yes Yes Yes
rSee 5 5 1IiII ;
Lastobond Shield/Pro HT-N/RESISTO SA I
SMOOTH PLY 40 Yes No No I�. �No Yes
1111 EE k
Lastobond Shield HT/Pro HT-S Yes • No No': es Yes -
Lastobond Eaves Protection Sheet
Lastobond 195 Yes No
ni
�� RdllYFa
Lastobond ECO /RESISTO LB1236,Grip- f a y
Rite Eave&Valley Protector/RESISTO Yes
LB1244
No Nod; o Yes Yes
Exterior Research and Design,I.I.C. Evaluation Report 518010.06.09-Rll
Certificate ofAuthariration#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-R13
Soprema,Inc. Revision 11:10/06/2017
;!
Page 3of8
I� 1
I .I
I i 'I
i
5
'\, TRINITY I ERD
TABLE 1: ROOF COVER OPTIONS
Asphalt Nail-On Foam-On Metal Wood Shakes&
Underlayment Shingles Tile Tile Shingles Slate
Lastobond Smooth Seal HT Yes . No No Yes. Yes_ Yes
Colphene FR GR Yes Yes Yes No Yes Yes
See 5.5.1
5.5.1 "Foam-On Tile"is limited to use of following Approved tile adhesives/underlayment combinations.
TABLE IA:ALLOWABLE TILE ADHESIVE/UNDERLAYMENT COMBINATIONS)
Adhesive Florida Product Approval Underlayments
Dow TileBond— FL22525 Lastobond TU HT
ICP Adhesives Polyset®AH-160 FL6332 Lastobond TU HT or Colphene FR GR
5.6 Allowable Substrates:
5.6.1 Direct-Bond to Deck:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond
Pro HT-S,Lastobond TU HT,Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond ECO,RESISTO
LB1236,Grip-Rite Eave&Valley Protector,RESISTO LB1244 or Lastobond Smooth Seal HT applied to:
➢ Plywood;ASTM D41 primed plywood; OSB;ASTM D41 primed OSB; Southern Yellow Pine;ASTM D41
primed Southern Yellow Pine;ASTM D41 primed structural concrete.
Colphene FR GR applied to:
➢ Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete.
Note:
➢ While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends
priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within
24 hours.
➢ Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to
installation of the self-adhering underlayment.
5.6.2 Bond-to-Insulation:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond
Pro HT-S, Lastobond TU HT,Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond ECO, RESISTO
LB1236,Grip-Rite Eave&Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR
GR applied to:
➢ Dens Deck Prime;SECU ROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam-on tile systems(Lastobond TU HT only),insulation attachment shall be designed by a qualified
design professional and installed based on testing of the insulation/underlayment system in accordance
with FM 4474,Appendix D,Testing Application Standard TAS 114,Appendix J or UL1807.
1 Refer to Tile Manufacturers orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design,U.C. Evaluation Report 518010.06.09-RSI
CerWicate ofAuthorizatlon#9503 6r"EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-R13
Soprema,Inc. Revision 11:10/06/2017
Page 4 of 8
FINITY I ERD
5.6.3 Bond to Mechanically Attached Base Laver: I
dl`
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 1195, Lastobond ECO, RESISTO
LB1236,Grip-Rite Eave&Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR
applied to:
➢ ASTM D226,Type I or II felt;Sopra-G;Modified Sopra-G. J
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam-on tele systems (Lastobond TU HT only),
base layer shall be attached in accordance with FRSA/TRI April 2012(04-12)
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications:i FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where
the underlayment forms part of the load-path. The following wind,�juplift limitations apply to underlayment
systems that are not addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile applications.
Maximum Design Pressure is the result of testing for wind load reisistance Rased on allowable wind loads,
and reflects the ultimate passing pressure divided by 2 (the 2 toil margin of safety per FBC 1504.9 has
already been applied). Refer to FRSA/TRI April 2012(04-12)or FBC' 1609 for determination of design wind
pressures.
#1 Maximum Design Pressure=-45.0 psf: J
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional)Elastocol Stick,Elastocol 600c or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered. I
#2 Maximum Design Pressure=-67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Elastocol 600c 1
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered.
#3 Maximum Design Pressure=-150.0 psf:
Deck: Min. 15/32-inch APA-rated BCX plywood (may,be installed C'side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and,idebris that may inhibit
adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp
splinters and wood projections shall be removed/sandeid.
Primer: (Optional)RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, self-adhered, shall be thoroughly roll using hand roller and/or
weighted roller to ensure there are no voids, aid ensure there are no voids/bridging at
side and end-laps. €
#4 Maximum Design Pressure=-60.0 psf: s ,
Deck: Min. 19/32-inch plywood to meet project requirements to"satisfaction of Authority
Having Jurisdiction. +
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached "ith nails (FBC 1517.5.1) and tin
caps (FBC 1517.5.2) spaced 6-inch o.c. at the{4-inch baps and 6-inch o.c. in three (3),
equally spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered
5.6.4.1 All other direct-deck, adhered Soprema underlayment systems: beneath; foam'-on tile systems carry a
Maximum Design Pressure of-45 psf. '
Exterior Research and Design,I.I.C. Evaluation Report 518010.06.09-Rll
Certificate ofAuthorkation#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-1113
Soprema,Inc. ? Revision 11:10/06/2017
Page 5 of 8
)
CTRINITYIERD
5.6.4.2 For mechanically attached Base Sheet,the maximum design pressure for the selected assembly shall meet
or exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1
design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria.
Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO
LB1236,Grip-Rite Eave&Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30-
days after installation.
Lastobond Shield,Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT or Lastobond
Pro HT-S shall not be left exposed for longer than 90-days after installation.
Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than 180-days after installation.
5.8 Tile Slippage Limitations(TAS 103 per FRSA/TRI April 2012(04-12)):
When loading roof tiles on the underlayment in direct-deck tile assemblies,the maximum roof slope shall
be as follows. These slope limitations can only be exceeded by using battens during loading of the roof
tiles.
TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIREcr-DECK TILE INSTALLATIONS
Underlayment Tile Profile Staging Method Maximum
Slope
Flat Max.10-tile stack 6:12
Lugged Max.10-tile stack 5:12
Max.10-tile stack(bottom 2-tile stack
shall be inverted,followed by 8 tiles high 6:12
on slope,as shown below)
Lastobond TU HT _
Lugged
Colphene FR GR Flat Max.10-tile stack 5:12
Lugged Max.10-tile stack 6:12
Exterior Research and Design,I.L.C. Evaluation Report 518010.06.09-1111
Certificate of Authorization 89503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-1133
Soprema,Inc. Revision 11:10/06/2017
Page 6 of 8
n
111' �RINIIY ER,D
6. INSTALLATION: '
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation
requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application,and prime theisubstrate with!Elastocol Stick, Elastocol
600c or RESISTO EXTERIOR PRIMER(if applicable).
6 3 Lastobond TU HT,Lastobond Shield,Lastobond Pro HT'N;RESISTO SA SMOOTH PLY 40,.Lastobond Shield.
4 HT, Lastobond Pro-HTS, Lastobond Eaves Protection Sheet, LaslLobond195,4LastobondYEco :lastoborid
t 1'
;Smooth Seal HT,RESISTO L61236;Grip}Rite Eave&Valley"Protector;`RESI5T0 LB1244 or.;Colphen`e TRGR: .
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
6.3.2 Non-Tile Applications:
While priming is optional, Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO
EXTERIOR PRIMER if the final roof cover is not slated for installation within;24 hours.
Apply,sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel-off the release fil`I°rl diagonally while holding the
membrane tight. Firmly roll the membrane into place to achieve all bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the llcourse below. 'IAII over-granule end-laps
shall be sealed using either heat-welding or hot air welding techniques. I
When installing at slopes above 8:12,Soprema recommends back-nailing,iin the overlap area at the top of
the sheet at 12-inch o.c. I ,
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths.1i Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the'center; of the valley or ridge in
each direction. For valleys,apply the sheet starting at the lowest point and!work upward.
6.3.3 Tile Applications(Lastobond TU HT or Colphene FR GR only):
V
Reference is made to FRSA/TRI April 2012 (04-12) Installation!Manual and Table 1 herein, using the
instructions noted above as a guideline. !
For foam-on tile applications,reference is made to Section 5.6.4 4rein for',wind resistance limitations that
fall outside the scope of FRSA/TRI April 2012(04-12).
Tile shall be loaded and staged in a manner that I s
� g prevents' the slippage it and/or damage to the
underlayment. See Table 2 herein,and Soprema published requirementsifor tile staging.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
!
Exterior Research and Design,I.I.C. 9 , Evaluation Report S18010.06.09-1111
Certificate of Authorization#9503 6n'EDITION(2017)FBC NON-HVHZ EVALUATION , FL2569-1133
Soprema,Inc. t Revision 11:10/06/2017
j' Page 7 of 8
i
I
TRINITY l ERD
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements.
The following plants have qualified products under their respective physical properties specifications.
Plant'.."' I Specification Product(s)
Lastobond Shield,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT,
Drummondville, Lastobond Pro HT-N,Lastobond Pro HT-S,Lastobond 195,Lastobond
QC(Canada) ASTM D1970 Eaves Protection Sheet,Lastobond Eco,Lastobond Smooth Seal HT,
RESISTO LB1236,PrimeSource Grip-Rite Eave&Valley Protector,
RESISTO LB1244
ASTM D1970&FRSA/TRI 04-12 Colphene FR GR
Wadsworth,OH Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Eco,
ASTM D1970 Lastobond Smooth Seal HT,RESISTO LB1236,PrimeSource Grip-Rite
Eave&Valley Protector,RESISTO LB1244
ASTM D1970&FRSA/TRI 04-12 Lastobond TU HT;Colphene FR GR
Gulfport,MS Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Eco,
ASTM D1970 Lastobond Smooth Seal HT,RESISTO LB1236,PrimeSource Grip-Rite
Eave&Valley Protector,RESISTO LB1244
9. QUALITY ASSURANCE ENTITY:
UL, LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
Exterior Research and Design,I.I.C. Evaluation Report 518010.06.09-1111
Certff tate ofAuthortzation#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-1113
Soprema,Inc. Revision 11:10/06/2017
Page 8 of 8
u
t '
I
BCIS Home Log In I User Registration Hot Topi s Submit Surcharge ' Stats&Facts'I Publications 'I FBC Staff I, BCIS Site Map
HondaoOr product ApprovalUSER:Public User
Product Approval Menu>Product or Application Search>Application Ust>Application Detail
a FL# FL5444-11121
Application Type Revision !
Code Version 2017
Application Status Approved ,
Comments
Archived I "
Product Manufacturer CertainTeediCorporation-Roofing
Address/Phone/Email 20 Moores Road
Malvern, PA119355 i
(610) 893-5400
mark.d.harder@saint-gobai,n.com
Authorized Signature Mark Harne'r
mark.d.harner@saint-gobain.com
Technical Representative Mark D. Hamer
Address/Phone/Email 18 Moores Road i
Malvern, PAi 19355
(610) 651-5847
Mark.D.Harner@saint-gobain.com
11 d I
Quality Assurance Representative !
Address/Phone/Email
1
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or e
Professional Engineer ;
Evaluation Report-Hatdcopy Received
a
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 03/09/2020
Validated By John W. Knlezevich PE
d° Validation Checklist- Hardcopy Received
i
Certificate of Independence FL5444 R1'2 COI 2017 01 COI Nieminen.Ddf
• i i
Referenced Standard and Year(of Standard) Standard Yea
ASTM D3161 201
I. w �
ASTM D3462 201
ASTM D7158 201
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 09/07/2017
Date Validated 09/12/2017
Date Pending FBC Approval 09/15/2017
Date Approved 12/12/2017
Summary of Products
FL* Model, Number or Name Description
5444.1 CertainTeed Asphalt Roof Shingles 3-tab,4-tab,strip (no-cut-outs), laminated an
asphalt roof shingles
Limits of Use Installation Instructions.
Approved for use in HVHZ: No FL5444 R12 II 2017. 09 FINAL ER CERTAIP
Approved for use outside HVHZ:Yes SHINGLES FL5444-R12.pdf
Impact Resistant: N/A Verified By: Robert Nieminen, PE PE-59166
Design Pressure: N/A Created by Independent Third Party:Yes
Other: Refer to ER Section 5 for Limits of Use Evaluation Reports
FL5444 R12 AE 2017 09 FINAL ER CERTAI
SHINGLES FL5444-R12.pdf
Created by Independent Third Party: Yes
Back ivext
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Ref
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pu
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not WE
address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee un(
please click here.
Product Approval Accepts:
Rig ®.
Credit:Card` J
;Safe. .
I,
EXTERIOR RESEARCH&DESIGN,LLC.
Certificate of Authorization//9503
������� i 353 CHRISTIAN STREET, UNIT#13
ERD ? ; OXFORD,CT 06478
i (203)262-9245
EVALUATION REPORT
CertainTeed Corporation Eva"luatioh Report 3532.09.05-1113
20 Moores Road FI5444-1112
Malvern;,PA 19355 i� �, Date of Issuance:09/22/2005
(610)651-5847 - Revision 13:09/05/2017
SCOPE: I l ;i
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules lfand regulation's governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume.l The products described
herein have been evaluated for compliance with the 6"t Edition(2017)Florida Building Code sections noted herein.
DESCRIPTION: CertainTeed Asphalt Roof Shingles.
LABELING: Labeling shall be in accordance with the requirements of the Accredited,Qualityj,Assurance Agency noted herein
and FBC 1507.2.7.1/R905.2.6.1
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s),'changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that relate toIthe product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Niem'inen, P:E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity IERD requires a completereview of this Evaluation Report
relative'to updated Code requirements with each Code Cycle. ,V ,i
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinityJERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to theluser by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Buildink6fficiall
This Evaluation Report consists of pages 1 through 12.
Prepared by:
�\�Uttt�tteniryr` � 'i
SCO:-�b�' �' �--•.� li �I
Robert J.M.Nieminen,P.E.
- fi•:^µ, The facsimile seal appearing was authorized by RobertNieminen,
Florida Registration No.59166,Florida DCA ANE1983 i P.E.on 09/05/2017.This does not serve as an electronically signed
•� dlnuunr�"}' document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interesOn any„company manufacturing or
distributing.products it evaluates.
2. Trinity)ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued. !!; I
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in`the approval process of the
product. '
5. This,is a building code evaluation. Neither TnnitylERD nor Robert Nieminen, P.E. are,)in anyway,the:Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for
it or design guidance unless retained
specifically for that purpose. II
F)o
JTRINRY I ERS
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: CertainTeed Asphalt Roof Shingles, as produced by CertainTeed Corporation, have
demonstrated compliance with the following sections of the a Edition(2017) Florida Building Code and 6t' Edition
(2017) Florida Building Code, Residential Volume through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Prope Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011
3. REFERENCES:
gntitf Examination Reference Date
UL(TST 1740) ASTM D3161 94NK9632 05/15/1998
UL(TST 1740) ASTM D3161 99NK26506 11/23/1999
UL(TST 1740) ASTM D3161 03CA12702 05/27/2003
UL(TST 1740) ASTM D3161 03CA12702 06/16/2003
UL(TST 1740) ASTM D3161 03NK29847 10/03/2003
UL(TST 1740) ASTM D3161 04CA11329 05/24/2004
UL(TST 1740) ASTM D3161 04CA32986 12/03/2004
UL(TST 1740) ASTM D3161 05NK07049 04/15/2005
UL(TST 1740) ASTM D3161 05NK16778 05/12/2005
UL(TST 1740) ASTM D3161 05CA16778 05/12/2005
UL(TST 1740) ASTM D3161 05NK14836 05/22/2005
UL(TST 1740) ASTM D3161 05NK22800 06/22/2005
UL(TST 1740) ASTM D3462 R684 09/21/2005
UL(TST 1740) ASTM D7158 05NK08037 06/28/2006
UL(TST 1740) ASTM D3161&D3462 09CA28873 07/23/2009
UL(TST 1740) ASTM D3462 10CA41303 10/07/2010
UL(TST 1740) ASTM D3161 10CA41303 10/08/2010
UL(TST 1740) ASTM D7158 10CA41303 10/27/2010
UL(TST 1740) ASTM D3161&D3462 10CA44960 11/11/2010
UL LLC(TST 9628) ASTM D3161,D3462&D7158 13CA32897 11/21/2013
UL LLC(TST 9628) ASTM D3161,D3462 TFWZ.R684 04/22/2014
UL LLC(TST 9628) ASTM D7158 TGAH.R684 04/22/2014
UL LLC(TST 9628) ASTM D3161&D3462 4786334434 09/16/2014
UL LLC(TST 9628) ASTM D3161&D3462 4786570826 02/12/2015
UL LLC(TST 9628) ASTM D3161,D3462&D7158 4786570717 12/16/2015
UL LLC(TST 9628) ASTM D3161&D3462 4787195678 02/09/2016
UL LLC(TST 9628) ASTM D3161,D3462&D7158 4787380356 10/26/2016
UL LLC(TST 9628) ASTM D3462 4787380357 10/13/2016
UL LLC(TST 9628) ASTM D7158 4787380357 11/08/2016
UL LLC(TST 9628) ASTM D3161 4787380357 11/09/2016
UL LLC(TST 9628) ASTM D3161,D3462&D7158 4787586427 01/25/2017
UL LLC(QUA 9625) Quality Control Service Confirmation Exp.03/09/2020
Exterior Research and Design,I.I.C. Evaluation Report 3532.09.05-Ri3
Certificate of Authorization#9503 6 EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R12
CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 13:09/05/2017
Page 2 of 12
TTRINITYIERD
4. PRODUCT DESCRIPTION:
4.1 CT20m,XTa"25,XT'""30 and XT'"'30 IR are fiberglass reinforced,3-tab asphalt roofshingles.
4.2 Arcadia"", Belmont®, Belmont® IR, Carriage House Shangle®, +Grand Manor,; Shangle®, Landmark'"',
Landmark'"' IR, Landmariff Pro, Landmarkm Premium, LandmarkTmI;TL, Landmark'"" Solaris and
LandmarkTM'Solaris IR are fiberglass reinforced,laminated asphalt roof shingles. �
4.3 NorthGate'"'is a fiberglass reinforced,laminated,SBS modified bitumen roof shingle.
� I I
4.4 Presidential Shake'", Presidential Shakd ' IR, Presidential Shake TLTM'1and Presidential Solaris'"" are
fiberglass reinforced,architectural asphalt roof shingles. I! ! '
4.5 Hatteras"",Highland Slate""and Highland Slate—IR are fiberglass�,einforced,4-tab asphalt roof shingles.
4.6 Patriot^" is a fiberglass reinforced asphalt roof strip-shingle (with no cut-outs) providing a laminated
appearance through an intermittent shadow line with contrasting blend drops for color definition.
4.7 Presidential Accessory, Accessory for Hatteras, Shangle Ridge"" I Shadow'Ridge"", Cedar Crest'TM, Cedar
Crest'"' IR, NorthGate Ridge and NorthGate Accessory are fiberglass reinforced accessory shingles for hip
and ridge installation.
4:8 Any of the above listed shingles may be produced in AR(algae resistant)versions.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
11 1
Designer of Record for any project on which this Evaluation Report, or previous-versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use within FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
5.4 Wind Classification:
5.4.1 All shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1iand R905.2.6.1 to ASTM
II
D3161,Class F and/or ASTM D7158,Class H, indicating the shingles are aecieptable for us in all wind zones
UP to Vasd = 150 mph (Valt= 194 mph). Refer to Section 6 for installationlrequire'ments to meet this wind
rating. !I
5.4.2 Presidential Accessory,Accessory for Hatteras,Shangle Ridge,Shadow Ridge,Cedar Crest, NorthGate Ridge
and NorthGate Accessory hip&ridge shingles have been evaluated in acc6'edancejwith ASTM D3161,Class
F. All except NorthGate Ridge and NorthGate Accessory require ruse of BASF Soriolastic NP 1 adhesive or
Henkel PL® Polyurethane Roof & Flashing Sealant, applied as specified'in manufacturer's application
instructions, for use in wind zones up to Vasd=150 mph(Vag=194 mph).: , '
5.4.3 Classification by ASTM D7158 applies to exposure category B or Cland a building height of 60 feet or less.
Calculations by a qualified design professional are required for conditions outside these limitations.
Contact the shingle manufacturer for data specific to each shingle.l; y,;
5.4.3.1 Analysis in accordance with ASTM D7158 indicates the measured uplift resistance(RT)for the CertainTeed
asphalt Roof shingles listed in Section 4.1 through 4.6(except Pre)identiallSolaris"') exceeds the calculated
uplift force (FT) at a maximum design wind speed of Vasd = 150 mph (Vali = 194 mph) for residential
buildings located in Exposure D conditions with no topographical variations (flat terrain) having a mean
roof height less than or equal to 60 feet. The shingles are permissible un'd'er Code for installation in these
conditions using the installation procedures detailed in this Evaluation Report and CertainTeed minimum
requirements, subject to minimum codified fastening requirements, established within any local
jurisdiction,which shall take precedence.
5.5 All products in the roof assembly shall have quality assurance audits in accordance with F.A.C.Rule 61G20-
3.
Exterior Research and Design,I.I.C. Evaluation Report 3532.09.05-1113
Certificate ofAuthorization 89503 6EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-1112
CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 13:09/05/2017
Page 3 of 12
TTRINIIWIERD
6. INSTALLATION:
6.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle
manufacturer's minimum requirements.
6.1.1 Underlayment shall be acceptable to CertainTeed Corporation and shall hold current Florida Statewide
Product Approval, or be Locally Approved per Rule 611320-3, per FBC Sections '1507.2.3, 1507.2.4 or
R905.2.3.
6,2 Installation of asphalt shingles shall comply with the CertainTeed Corporation current published
instructions, using minimum four(4) nails per shingle in accordance with FBC 1507.2.7 or Section R905.2.6
and the minimum requirements herein.
6.2.1 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.2 Where the roof slope exceeds 21 units vertical in 12 units horizontal,use the"Steep Slope"directions.
6.3 CertainTeed asphalt shingles are acceptable for use in.reroof(tear-off)or recover applications,subject to the
limitations set forth in FBC Section 1511 or R908 and CertainTeed published installation instructions.
6.4 CT201i XT'25,XT'30,Xrt"30 IR:.
LOW AND STANDARD SLOPE 3TEEP`SLOPE
ENGLISH 12" 12" 12" Use four nails and six spots of asphall roofing cement*for every full
-(305 mm)— .(305.mm)—•_ (305 mm)__i shingle(Figure 11-4).Asphalt roofing cement meeting ASTM D4586
td
m) — taut_ 1"(25InType IIIs suggested.
5 3/a"(145 mm5r12Planfotgro
METRICt� 1
k. 131/a" 131/a" +— 131/e" r
Mi
Rong Cement
1.'(25 mm) Sealant L1'(25 mm) Apply 1''(25 mm)spots of asphalt roofing cement
_ under each lab corner.
6 Va" Figure il,4..usefour nails andsix spots of6spbalt ceinenton sleep.slopes:
T *CAUTION:Excessive use of roofing-cement can cause shingles
to blister.
Figure ll-3:Usefoxrnailsforeveryfulfsbingle.
6.4.1 Hip&Ridge for CT201,XTI 25,XTa"30,XT''30 IR: Cut Shingles
(251mmill+
i
2"(50rtun}II�Remove�tl
I I g'—►�;l12".(305mm)�`Is\ea
go\R
"FS
f (125 mm)
d 12,. �� �,`�5
Cap _ _ Cap _ _ .Cap 305inm)
Shingle Shingle Shingle yg Sho`Rn
Figure 11-24.-Cut tabs,then trfinback to make cap shingles
(English dimensions shown).
Figura 11-25:Installation of-ps along the Gips and ridges.
6.4.1.1 For ASTM D3161,Class F performance use BASF"Sonolastic®NPrm"adhesive or Henkel "PLO Polyurethane
Roof&Flashing Sealant",in accordance with CertainTeed requirements.
Exterior Research and Design,LLC. Evaluation Report 3532.09.05-R13
Certificate of Authorization#9503 6EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R12
CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 13:09/05/2017
Page 4 of 12
I ,
I i �6ti�-
;'' tRINITY I ERD
,,.
6.5 ARCA
LOW'AND STANDARD SLOPE STEEP SLOPE I �'
Use SLY nails for every full sltingle located as shown below. Use SIX nails and FOUR spots.,of asphAt roofing cement for every full
shingle as shown below.Apply,asphalt roofing cement 1"(25 mm)
from edge of shingle.AspUtioofmg cement meetingASTDI D 4586
14pe II is suggested.
f
1'(25 rant) 1'(25 mm)—
Nail I� I i
I
Nail I t � ,�
Nail Li z
ffi'�(25 mm) 1'(25 mm)—►
I I
Figure 2:Use sir nails for every fall sbiugle.
Figure 3:Use sir mmlls mrdfour sp is of aspGall
;roofrag Cei(rent on steep slopes.
6.5.1 Hip&Ridge for Arcadia'"": Cedar Crest'"',Cedar Crest'IR
Use two (2), minimum 1%-inch long fasteners per shingle. For the starter shingle, place fastener 1-inch
from each side edge and about 2-inch up from the starter shingles exposed butt!edge,ensuring minimum
%-inch embedment into the deck,or full penetration through the deck. For each full Cedar Crest shingle,
place fasteners 8-5/8-inch up from its exposed butt edge and 1-in'ch from each side edge.
For ASTM D3161,Class F performance use BASF"Sonolastic®NP11""adhesive or Henkel "PL®
Polyurethane Roof&Flashing Sealant",in accordance with Certa nTeed requirements,to hand-seal
Cedar Crest shingles. Apply NP 1 or PL adhesive from the middle of the sh'ingle's�raised overlay on the
top piece and extending approximately 4-inch along the sides of the headlap along a line%to 1-inch from
each side of the shingle's headlap. Immediately align and apply the overlying shingle,gently pressing tab
sides into the adhesive,and install nails. To secure the other side;apply a 1-inch,diameter spot of NP 1 or
PL adhesive between the shingle layers. l ;I
j[Hand-sealing adhesive
li f
I �
S" m) 5 114'
(39 4,.
203 sure
`25m� 314"—► I�
x!`219 mcol
II ' 1n
Da'b of asphalt
cement between 1„
I
shingle layers
I '
Exterior Research and Design,I.I.C. i Evaluation Report 3532.09.05-1133
Certificate of Authorizatfon#9503 6r"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-1112
CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 13:09/05/2017
Page 5 of 12
r ,
TRINITY ERD
TO OR BELMONT®IR:
6.6 BELMON ,
Low=and.Standard Slope 'Steep-Slope(greater than 21:12)::.
(2A2-to 21:12):: Use SEVEN nails and EIGHT spots of
Use FIVE nailsfor every full'Belmont shingle, asphalt roofing cement*'for every full
located as shown below. Belmont shingle.Apply asphalt roofing
+ cement I"(2,5mm)from edge of shingle
tt
fin
See below.Asphalt roofing cement meeting
ASTM D4586 Type 11 is suggested_.
52'(16nrn) - 85(8' t1P1'(h'3mm)
. /
orldddionzlra:lsilrequired. Ji. ;--} I"-7'i25mn) 1'(25 min)--�I -+--
(7101I ren)
}
t'(?smcn) R�fing.ccmerd
6.6.1 Hip&Ridge for Belmont®or Belmont®IR:
6.6.1.1 Option 1: For Belmont®,refer to instructions herein for Cedar CrestTM'or Cedar Crest''IR hip and ridge
shingles. For Belmont®IR,refer to instructions herein for Cedar Crest'"'IR hip and ridge shingles.
6.6.1.2 Option 2: For Belmont®: Shangle®Ridge
--12• 18• Remove tape
Exposure from the right side
1 ; 8-,j and fasten
SECOND
Fasten the a
left side RIGHT
FIRST
Remove as/8�
This Tape LEFT
Figure 17-19:Installation of Sbangleo Ridge sbingles
Figure 17-18:.Sbangleo Ridge. on hips and ridges.
6.6.1.3 For ASTM D3161,Class F performance use BASF"Sonolastic®NP1 "adhesive or Henkel"PL®
Polyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements.
Exterior Research and Design,U.C. Evaluation Report 3532.09.05-1113
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-1112
CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 13:09/05/2017
Page 6 of 12
'i k II
RINITY I ERD
! 6.7 CARRIAGE HOUSE SHANGLE®AND GRAND MANOR'•SIiANGLE® K1 '
LOW.'AND STEEP SLOPE
STANDARD SLOPE Use:seven nails and three'sptits of aspgalt roofing cement for every
full Grand Manor Shangle.lI't liven its and three spots of asphalt
Use five nails for every full Shangle. i
roofing cement fur every bill arriage douse Shangle and Centennial
Slate;Apply-At roofing.ccment 1"(25 mm)from edge of shingle
t
(Figure 175).Asphalt roofiiil;ceuteat;meeling AST1i,Di58G 1)gell
is suggested.
(25 mm) i
518 85/8" I i; (38 mm)
(16mm) (220 mm) 11. ess 1•.
(25 mm) (25 Mm)
i
Fignrel74bsefitpnatlsforeteryfullCrand,11anorSbangle, Sly 8518
Carriage Howe Sbangle,or Centennial SlalF (t 6 mm)j l }� , (220 mm)
(25mm)T !''+ Roofing Cement
II g';i "
Figure 17--5:I Wn btstallU{g'CrandJ1dnorSbangles ort steep slopes,
rise seremnails and flove spots ofaspbatl roafing cement.
6.7.1 Hip&Ridge for Carriage House Shangle®and Grand Manor Shan{ele:Refer to instructions herein for
Shangle®Ridge hip and ridge shingles
6.8 LANDMARK'"",IANDMARK""cIR,LANDMARK"a PRO,,LANDMARKT"P�REMIU ,aLANDMARK'"'TL,LANDMARKTM
TOW AND STANDARD.SLOPE LANDMARK TL
METRIC DIMENSIONS �13t12 r 13'. 131l2"
{�-343 mm) H,r in) x-(343 mm) ►{
12" 143/4" 12" ill;1"(25 mm)'i 'i 1"(25 mm)--
[—(305 in
fitx-(375�m-m)—�-* —�r(305.mm)-
ax(25 mm) x„ sTape ►� I ,{ (, d-
1"(25
Nailable
Area Figur 13 4 Use,Or nails for ereo-f d shingle
NorthGate:
it
httUYSt 12• 14VtV Il 1r
'-. (305 (375 mm) -+-(JO5 mm)
TRINi-ry l ERD
STEEP SLOPE
Use six nails and four spots of asphalt roofing cement for every ftill LANDMARK TL
laminated shingle.See beloxv.Asphalt roofing cement should meet
TM 045861ype II.Apply 1"spots of asphalt roofing cemenrnnde 131/2 13" 131!2'`
each corner and at about'12"to 13"m•from each edge. r (343 mm) (330 mm) (343 mm)
f
METRIC DIMENSIONS (1-1"t25 mm 1"(25 mm)-
) I
r(30
12" 1. 143/4.' �-12'
5 mm) (375`mm) (305;mm) „ 1"
(25 mm) ---- (25mrn):
��,:ra:�.s�=� .:��-�.£ ��.:� Rooting Cement
(
f�1 25mm.) fielea eTape 1 (25mm-� �—
Nail Qtea�{
FoGSteep Figure 13-5.'Use sfz ngils antifora spots of
as Galt roofing cement on steep stop-
(251.
to es.(251.in --- (25 mm,*
Roofing CemenC
NorthGate:
STEEP` 12" 14-314" :12"
SLOPE -
.. -(80.5'mm)�+► (375 inrn 4--(305 mmY►1.
NAILING Nailing mits
,. ._
AREA( bettiveertypsrer
rr –► .=1°(25 mm) nal rues. 1e(25 mrn}
R �
Roofing Gement
Nailing areas for steep slopes(gretatet than 2112)
and"Stonn-Nailing
Nail between Immer 2 nail lines as sfibim above.
6.8.1 Hip&Ridge for Landmark'TM,LandmarkTM'IR,LandmarkTM Pro,Landmarkm Premium,Landmark'TL,
LandmarkTM Solaris,LandmarkTM'Solaris IR,NorthGate:
6.8.1.1 Option 1: Shadow RidgeTM'or NothGate Accessory
12` 97/a"
(305mm) (250mm)
67 6,
(150mm) (150mm) (Mrnm) I (125mm)
Notch for Notch for
Centering �c Centering
12" \ /� 131/4' 1
(305mm) NotchesforAlignmentto (337
mm) Notches for Alignment to
LL5
the Top Edge of the Previous 7° the Top Edge of the Previous 7.18"
Cap fors'(125mm)Exposure(iaomm) Capfor55A'(141mm)RPM're'(1 m)
English Dimension —}I Metric Dimension
Shadow Ridge'"' Shadow RidgeTM'
Exterior Research and Design,I.I.C. Evaluation Report 3532.09.05-R13
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R12
CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 13:09/05/2017
Page 8 of 12
I I
l)
A .f
TRIIUITY I ERD
(250 rtan) { it
�1511G(t25�un) I �i i ,i
'i 1318"
=(333 mm)—►1
Getttcrimg;P)o cfi Ir'E.5/8"-►1'f
('1$8 mm)ii(1 68 mm
�1
(337 Writ.) p�igst ttf"sse !{ Centering
1tAtChCS ltYp T �. 131!4° !' Notch '
000 n3 (►9;tt m) 1337 mm) I
p avioust0ur e I I i Align.these 7 518°
notches to top (194 mm)
edge of {
a 1 3previoug course.,
NorthGate Ridge No' GatelAccessory
12. t h
r305mm)
Laying Notch; I
y
`' II
125010) I I
osure
al g g i, p - `I
Figure 13 20.Use( to notches to c�ntorsli{n les on Ld s air{
ridges and to locate Me correct posrire.
6.8.1.2 For ASTM D3161, Class F performance use BASF "Sonolastic® NP1*" adhesive or Henkel "PL®
11 Polyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements.
6.8.1.3 Option 2: Refer to instructions herein for Cedar Crest',Cedar Crest'"IR hip and ridge shingles.
JJ i
I 'I
r• 0
1:
Exterior Research and Design,I.I.C. I k Evaluation Report 3532.09:05-Ri3
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION II S ij FL5444R12
CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 13:09/05/2017
Page 9 of 12
j
1
TRINITY JERD
6.9 PRESIDENTIAL}SHAKE!'",PRESIDENTIAL SHAK'iym,IR,PRESIDENT IALSHAKE TLIn PRESIDENTIAL`SOLARIS m
LOW AND'STANDARD SLOPE: STEEP SLOPE:
For low And-standard slopes,use five nails for each full.Presidennal For steep slopes,.use nine nails for each full Presidential shingle and
shingle as shown below. apply 1'diameter spots of asphalt roofing cementunder each shingle.lab.
After applying 5 nails In behveen the naft,gulde lines;apply nailsd"
Nailing h. 40' .h_ abovelab cutouts malting certain tabs of overlying'shingle cover nails.
Guide Cines (1016.rTlm)
5
(133 M mm) . .. 141/4"
f_t 112° 38 min). (362 mm): • • 11
NOTE:Apply nails on painted guideline.
Figure 16-6 Fastening Presldentialand'PresidenflatTL'Sbnke 1°diameter asphalt roofing cement
shingles on low andstandard slopes
Figure 16-7.•Fastening Presidential and hesidenlial TIL Shake
sbingles;on steep.slopes:
6.9.1 Hip&Ridge for Presidential Shake'"',Presidential Shake'IR,Presidential Shake TLI,Presidential
Solaris'"':
6.9.1.1 Option 1:Presidential Accessory
PRESIDENTIAL ACCESSORY
Presidential accessory shingles can be-used for coverin&ps and
ridges.Apply shingles up to the ridge(expose no more than 1"from
the bottom edge of the"tooth,"Fasten each accessory with two fas-
teners.The fasteners must be 13/4"long or longer so theypenetrate
either 3/4"into the deck.or completely through.the deck.Presidential
accessory comes in two differentsiies:Accessory produced in
Birmingham,.AL'is 12"x 12;Portland,ORproduces 97/8"--X 131%4"
accessory.
6.9.1.2 For ASTM D3161, Class F performance use BASF "Sonolastic® NP1' adhesive or Henkel "PL®
Polyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements.
6.9.1.3 Option 2:Refer to instructions herein for Cedar Crest',Cedar Crest'IR hip and ridge shingles.
6.10 HATTERAS!"
LOW,STANDARD.-AND STEEP-SLOPE: l (230mm) {230 mm) {230mm)- (230tmn) I
I (230 mm) (2301nm) x(230 mm) (230 mm) I t
I—(2b mm)_e __(25 mm)_� t (240 MM)
8�. noofin0 Ceinenl` ^
:240 rnnn)
Fignm 15-1-.Foslei+ingan 5lcr/iSloprs
rwsieep slopes use Gee 6.0i'and elgla spots of asphalt roofing
Figure 15:3:ildsleningalnaerasShingles oa content for each full Il,ateras si ingic.as shown aboar.Apply i"
Lair anrlUdi ihnd.volxs (25mm)thaiaMer silos of roofing ceatent(AS-11,J)4586 Type it
For low and standard slopes;use$re mills for a di Gall suggested)under each tab`cornec Bross shingle into place;'do not
)latteras shingle ass bonm above expose cement.
CAUTION:Too much roofing Cement can.cause shingles to blister.
Exterior Research and Design,I.I.C. Evaluation Report 3532.09.05-Ri3
Certificate ofAuthorization#9503 6!"EDITION(2017)FBC NON-HVHZ EVALUATION F1.5444-1112
CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 13:09/05/2017
Page 10 of 12
i i E li
:4. i
" RIf 1I Y ERD
i
6.10.1 Hip&Ridge for Hatterasm: I'
6.10.1.1 Option 1: Accessory for Hatteras
, I r
Fasten bolYlsldes �
1
,
I
Mgure 15-14r 18 tWe piedo units separate ffio trtake' t \ i
54 HadteritsAcrwory shins.EEl'
6.10.1.2 Option 2: Cut Hatteras Shingles
4i� I
—T� l 'I
(23_Q:mm),I ^
fi r�-1f3'i(466 mm? Q,ath
-- -- ----1--- 18.. 3-mm� .rc� 5�a�
460 mm) I X205
` 1
Cap Cap Cap Cap
, Shingle Shingle Shingle Shingle �•93t
.I EIS. a
Figure 15-20.Cut Hatt2ras,sbdngles to Henke cower cap. Figure 15,21 ImMlll�ztion o' caps.along baps and ridges.
.6.10.1.3 For ASTM D3161, Class F performance use BASF "Sonolastic® NP1T""' adhesive or Henkel "PL® Polyurethane
Roof&Flashing Sealant",in accordance with CertainTeed require"ents. '!? !,
Ntk
6.11 HIGHLAND SLATE'"',HIGHLAND SLATE'"'IR' S 1 t ? 1 �'Fa '
„
[OW AND STANDA DILOP6 STEEP SLOPE
9 y g_ Use ME nails and H1G1Pr'spof I of asphalt roofing cement*for each
9mm4 Po-A t ) tz{9mm) full High Iand Slate shingle.For Aamf-Dade;SIX nails are required.
Apply 1'(diameter spoil of asphaltrootingcement-under each lab
as j Rsmnl
comer.A'sphaltroofing'.t1ementm1tingASTMD'4536Type Itissuggested.
f
Wo mm7 (M—) 3. i
(240 M14
tdieini>DaderequUes
i SIX nails1 nails- 1`(25 mm)..
Walled over center ' ': s•sra•
culowasamm). NEamWaderequirH (25
i sl%nads(twom 1 J_.
installed orbr cauls( l �:• ` .`
slow M
Figure 11-3:Use FIVE natisforevery Highland Slate sLing/a , i Roofing Cement
Id !'
I lgare 113 ;Use MW rrMk and eight spots ofaspbati
roofih vvientandereachrubcorner.
"CAUTI6N Excessive use of roofing cement can cause shingles
to blistero f!
6.11.1 Hip&Ridge for Highland Slate"l,Highland Slaters°'IR:Refer to instructions,herein for Cedar Crestrm,Cedar
CrestTM'IR or Shangle Ridge'"e hip and ridge shingles.
Exterior Research and Design,I.I.C. i Evaluation Report 3532.09.05-R13
Certificate ofAuthorization#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION I„ FL5444-R12
CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 13:09/05/2017
Page 11 of 12
E, li
F)o
TRINITY�ERS
6.12 PATRIOT'""
LOW AND STANDARD SLOPE STEEP SLOPE
Use FOIiIt nails for every full shingle locatedas ltoun:Uelo«�
USe 1`01111 nails and four spots of asphalt roofing cement fore'iery full
shingle as shown below;Asphalt roofing cement meeting jW3\1 D4586
1Wpe 114s suggested.Apply 1'(25 num)spots of asphalt roofing
'sealml cemeiit•ns shown.
1,t
F(25,, -—— 25m9
CAUTION:1-xcessiee use of,roofing cement can muse shingles to blister.
G/g,+ 1
t (333) " (333,-) rua t"i�)------
i tzsr�mmi
(156 M)I•' ri o
,nnollnB Cement
If:f2-1B' -«�+ f3115 - -` 1 am
6.12.1 Hip & Ridge for PatriotTm: Refer to instructions herein for Cedar Crest', Cedar Crest' IR, Shadow Ridgem,
NorthGate or Shangle Ridge''hip and ridge shingles.
7. LABELING:
7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the
Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table
1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this
product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(414)248-6409;karen.buchmann@us.ul.com
-END OF EVALUATION REPORT-
Exterior Research and Design,U.C. Evaluation Report 3532.09.05-1113
Certififcote ofAuthorkotfon#9503 aEDITION(2017)FBCNON-HVHZ EVALUATIONFL5444-R12
CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 13:09/05/2017
Page 12 of 12