Loading...
HomeMy WebLinkAboutDrawing I I I 1 ' I I I I ' J I I ' 1 � I I I ' I i w 36" X 80" I I REPLACE DOOR IN 1 OPENING ONLY.'' NEW DOOR TO BE IMPACT RESISTANT-' HURRICANE SHUTTERS NOT REQUIRED. II ' i I I OPENING PRODUCT DESIGN OPENING SQ. WIND PRESSURES APPROVAL PRESSURES I COMMENTS NO. WIDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. ' NEG. 1 36 80 20.00 4 43.8 1 -47.7 FL22378.5 55.0 1 1 -55.0 I FRONT ENTRY-LSMI I ' I REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS. NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS. i ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS. ' I . I , LESS THAN 30%OF STRUCTURE'S VALUE.NOT A RENOVATED BUILDING.EXEMPT FROM 2017 ENERGY CONSERVATION CODE. SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES ' DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES i MEAN ROOF HEIGHT= 11 FT 2 IN PANTONO DUPLEX RESIDENCE 91 S. LAS OLAS DRIVE DOOR REPLACEMENT PLAN 1 JENSEN BEACH, FLORIDA j I