Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval
Florida Building Code Online Page 1 of 2 Business & Professional Regulation BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Stag BCIS Site Map Links Search Product Approval USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail RECEIVED FL# FL5444-R13 FEB 2 2 2018 Application Type Revision Code Version 2017 Application Status Pending FBC Approval ST. Lucie County, PerMitting Comments Archived Product Manufacturer CertainTeed Corporation-Roofing Address/Phone/Email 20 Moores Road Malvern,PA 19355 (610)893-5400 mark.d.harner@sal goba lL Y E COP Authorized Signature Mark Harper mark.d.harner@saint-gobain.com Technical Representative Mark D.Harper Address/Phone/Email 18 Moores Road Malvern, PA 19355 (610)651-5847 Mark.D.Harner@saint-gobain.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 03/09/2020 Validated By John W. Knezevich, PE [_ Validation Checklist-Hardcopy Received Certificate of Independence FL5444 R13 COI 2018 01 COI NIEMINEN odf Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2011 Equivalence of Product Standards Certified By Sections from the Code https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtahl g07CSsoycOr12... 2/22/2018 Florida Building Code Online Page 2 of 2 Product Approval Method Method 1 Option D Date Submitted 01/24/2018 Date Validated 01/29/2018 Date Pending FBC Approval 01/30/2018 Summary of Products FL# Model,Number or Name Description 5444.1 CertainTeed Asphalt Roof Shingles 3-tab,4-tab,strip(no-cut-outs),laminated and architectural asphalt roof shingles Limits of Use Installation Instructions Approved for use in HVHZ: No FL5444 R13 II 2018 01 FINAL ER CERTAINTEED ASPHALT Approved for use outside HVHZ: Yes SHINGLES FL5444-R13.Ldf Impact Resistant: N/A Verified By: Robert Nieminen,PE PE-59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER Section 5 for Limits of Use Evaluation Reports FL5444 R13 AE 2018 01 FINAL ER CERTAINTEED ASPHALT SHINGLES FL5444-R13.Ddf Created by Independent Third Party:Yes Back Next Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here_. Product Approval A��ccc1e''k�'p�ts: ® Iii Credit Card ■ Safe �I https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtahl g07CSsoycOrl2... 2/22/2018 RECEIVED NEM01 etc. FEB 2 2 2018 Certificate of Authorization#132455 ST. Lucie County, Permitting 353 Christian Street, Unit#13 Oxford,CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY EVALUATION REPORT CertainTeed Corporation aluation Report 3532.09.05-R14 20 Moores RoadFILE FL5444-1113 Malvern, PA 19355 Date of Issuance:09/22/2005 (610)651-5847 Revision 14:01/24/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition(2017)Florida Building Code sections noted herein. DESCRIPTION: CertainTeed Asphalt Roof Shingles. LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMOIetc, requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 13. Prepared by: Robert J.M. Nieminen,P.E. Florida Registration No.59166, Florida DCA ANE1983 's;TF�'�=^=�C;'`,;-',: The facsimile seal appearing was authorized by Robert ,''•,,s'`;��'a�:�,.� Nieminen,P.E.on 01/24/2018. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO I etc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEW I etc.is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither NEMOletc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. U(14 MEMO I etc. ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: CertainTeed Asphalt Roof Shingles, as produced by CertainTeed Corporation, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code and 6th Edition (2017) Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: Entity Examination Reference Date UL(TST 1740) ASTM D3161 94NK9632 05/15/1998 UL(TST 1740) ASTM D3161 99NK26506 11/23/1999 UL(TST 1740) ASTM D3161 03CA12702 05/27/2003 UL(TST 1740) ASTM D3161 03CA12702 06/16/2003 UL(TST 1740) ASTM D3161 03NK29847 10/03/2003 UL(TST 1740) ASTM D3161 04CA11329 05/24/2004 UL(TST 1740) ASTM D3161 04CA32986 12/03/2004 UL(TST 1740) ASTM D3161 05NK07049 04/15/2005 UL(TST 1740) ASTM D3161 05NK16778 05/12/2005 UL(TST 1740) ASTM D3161 05CA16778 05/12/2005 UL(TST 1740) ASTM D3161 05NK14836 05/22/2005 UL(TST 1740) ASTM D3161 05NK22800 06/22/2005 UL(TST 1740) ASTM D3462 R684 09/21/2005 UL(TST 1740) ASTM D7158 05NK08037 06/28/2006 UL(TST 1740) ASTM D3161&D3462 09CA28873 07/23/2009 UL(TST 1740) ASTM D3462 10CA41303 10/07/2010 UL(TST 1740) ASTM D3161 10CA41303 10/08/2010 UL(TST 1740) ASTM D7158 10CA41303 10/27/2010 UL(TST 1740) ASTM D3161&D3462 10CA44960 11/11/2010 ULLLC(TST 9628) ASTM D3161,D3462&D7158 13CA32897 11/21/2013 UL LLC(TST 9628) ASTM D3161,D3462 TFWZ.R684 04/22/2014 UL LLC(TST 9628) ASTM D7158 TGAH.R684 04/22/2014 ULLLC(TST 9628) ASTM D3161&D3462 4786334434 09/16/2014 ULLLC(TST 9628) ASTM D3161&D3462 4786570826 02/12/2015 ULLLC(TST 9628) ASTM D3161,D3462&D7158 4786570717 12/16/2015 ULLLC(TST 9628) ASTM D3161&D3462 4787195678 02/09/2016 ULLLC(TST 9628) ASTM D3161,D3462&D7158 4787380356 10/26/2016 ULLLC(TST 9628) ASTM D3462 4787380357 10/13/2016 ULLLC(TST 9628) ASTM D7158 4787380357 11/08/2016 ULLLC(TST 9628) ASTM D3161 4787380357 11/09/2016 ULLLC(TST 9628) ASTM D3161,D3462&D7158 4787586427 01/25/2017 ULLLC(TST 9628) ASTM D3161&D3462 4788042412 11/15/2017 UL LLC(QUA 9625) Quality Control Service Confirmation Exp.03/09/2020 NEMO ETC,LLC Evaluation Report 3532.09.05-1134 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FLS444-R13 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018 Page 2 of 13 ONEMOletc. 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 CT20T-,XT'-25,XT'"30 and XT'"30 IR are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Arcadia'"', Belmont®, Belmont® IR, Carriage House Shangle®, Grand Manor Shangle°, Landmark'"', Landmark— IR, Landmark'"" Pro, Landmark'"" Premium, Landmark'"' TL, LandmarkTM' Solaris and Landmark'"Solaris IR are fiberglass reinforced, laminated asphalt roof shingles. 4.1.3 NorthGate'"is a fiberglass reinforced, laminated,SBS modified bitumen roof shingle. 4.1.4 Presidential Shake'"", Presidential Shake'"" IR, Presidential Shake TL'"' and Presidential Solaris'' are fiberglass reinforced,architectural asphalt roof shingles. 4.1.5 HatteraSTM, Highland Slate—and Highland Slate'" IR are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.6 Patriot'"' is a fiberglass reinforced asphalt roof strip-shingle (with no cut-outs) providing a laminated appearance through an intermittent shadow line with contrasting blend drops for color definition. 4.2 Hip&Ridge Shingles: 4.2.1 Presidential Accessory, Accessory for Hatteras, Shangle RidgeTM, Shadow Ridge'"', Cedar Crest'"', Cedar CreStTM IR, NorthGate Ridge and NorthGate Accessory are fiberglass reinforced accessory shingles for hip and ridge installation. 4.3 Accessory Starter Strips: 4.3.1 SwiftStart® Starter Shingle is a starter strip for asphalt roof shingles. Its overall size of 15-1/4" x 38-3/4" yields two(2)7-5/8"x 38-3/4"starter pieces per shingle. 4.4 Any of the above listed shingles may be produced in AR(algae resistant)versions. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMOJetc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use within FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 All shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for us in all wind zones Up to Vasd = 150 mph (V„it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 Presidential Accessory, Accessory for Hatteras, Shangle Ridge, Shadow Ridge, Cedar Crest, NorthGate Ridge and NorthGate Accessory hip & ridge shingles have been evaluated in accordance with ASTM D3161,Class F. All except NorthGate Ridge and NorthGate Accessory require use of BASF Sonolastic NP 1 adhesive or Henkel PL® Polyurethane Roof & Flashing Sealant, applied as specified in manufacturer's application instructions, for use in wind zones Up to Vasd= 150 mph (V,,,= 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 SwiftStartl Starter Shingle has been evaluated in accordance with ASTM D3161,Class F. Refer to Section 6 for installation requirements to meet this wind rating. 5.4.4 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. NEMO ETC,LLC Evaluation Report 3532.09.05-1114 Certificate of Authorization#32455 6'"EDITION(2017)FBC NON-HVHZ EVALUATION F1.5444-1113 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018 Page 3 of 13 ONEMOletc. 5.4.4.1 Analysis in accordance with ASTM D7158 indicates the measured uplift resistance(RT)for the CertainTeed asphalt Roof shingles listed in Section 4.1 through 4.6(except Presidential Solaris'") exceeds the calculated uplift force (FT) at a maximum design wind speed of Vmd = 150 mph (V„It = 194 mph) for residential buildings located in Exposure D conditions with no topographical variations (flat terrain) having a mean roof height less than or equal to 60 feet. The shingles are permissible under Code for installation in these conditions using the installation procedures detailed in this Evaluation Report and CertainTeed minimum requirements, subject to minimum codified fastening requirements established within any local jurisdiction,which shall take precedence. 5.5 All products in the roof assembly shall have quality assurance audits in accordance with FAC Rule 611320-3. 6. INSTALLATION: 6.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.1 Underlayment shall be acceptable to CertainTeed Corporation and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Installation of asphalt shingles shall comply with the CertainTeed Corporation current published instructions, using minimum four(4) nails per shingle in accordance with FBC 1507.2.7 or Section R905.2.6 and the minimum requirements herein. 6.2.1 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.2 Where the roof slope exceeds 21 units vertical in 12 units horizontal, use the"Steep Slope"directions. 6.3 CertainTeed asphalt shingles are acceptable for use in reroof(tear-off)or recover applications,subject to the limitations set forth in FBC Section 1511 or R908 and CertainTeed published installation instructions. 6.4 SWIFTSTART*STARTER SHINGLE: Fastening: Use four nails, located as shown below I38-3/4"(984 mm) I 4 1" (25 mm)from edge 1'(25 mm)from edge —•► 7-5/8' Max3` « « « : (194 mm) (76 mm) T 1 The inner two fasteners must be placed such that they fall at least 3"(76 mm)from the end joints of the shingle in the succeeding course. NEMO ETC,LLC Evaluation Report 3532.09.05-1114 Certificote of Authorization#32455 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-1113 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018 Page 4 of 13 ONEMOjetc. 0 • LOW AND STANDARD SLOPE STEEP SLOPE ENGLISH 12" 12' Use four nails and six spots of asphalt roofing cement*for every full shingle(Figure 11-4),Asphalt rooting cement meeting ASTM D4586 ~-1"(25 mm) _se lint (25 mm) Type II is suggested. 5 i;2"!or'Jarwood —— —_ Plant — — — — —— NfETRK l3'ya'' .. 181/8" Rooting Cameal 1 t'(25-1 ) Seall4t 1"(25tnrn) Apply 1"(15mmjspots ofasphalt Foo. inyrement Wet aach tat:uy r. Figure I f-4:Use four nails imd sir stook ofasphalt ct+rrrmton sleep slay)!& *CAUTION.Excessive use of roofing cement can cause shingles to blister. Figure 113:Use four nails for ery rj fu't str'ngle. 6.5.1 Hip&Ridge for CT.2{0TM,XTTm 25,XT`"30,XT`"30 IR: Cut Shingles Remove _"1 25 mm �' ;305 mnl) �vYh +r 5"O y y % (125 mm) I� - - C' % � �,l2gttstcl C Lap Gap Cap Stirg� 9liiegF Sunga � ��� .���ono figure 11-24:Oil labs,then trim brk-k to snake cap shingles (F,nglrsh dimensions shoum). L� Figrtre 11-25:installation gf hsps along the hips and rldgt s. 6.5.1.1 For ASTM D3161, Class F performance use BASF "Sonolastic® NPl`"' adhesive or Henkel "PLS' Polyurethane Roof&Flashing Sealant", in accordance with CertainTeed requirements. 6.6 ARCADIA": LOW AND STANDARD SLOPE STEEP SLOPE Use SIX nails for every full shingle located as shomi below. Use SIX nails and FOUR spots of asphalt roofing cement for every full shingle as shown below.Apply asphalt roofing cement I'(25 nun) from edge of shingle.Asphalt roofing cement meeting,ASM D 4586 Type Il is suggested. —t'(25 m n) V(25 mml--f wiTtine i Nal lhe T?25 mm; LL Figure 2:('se sir nulls far ervrry fullsbingde. L"L Ec, C, Figure 3.Vse sir nails and fora syxrts of aspiwilt rrxtfrng cement on steep sloo s. NEMO ETC,LLC Evaluation Report 3532.09.05-1114 CertificoteofAuthorization#32455 6?"EDITION(20 L7)FBC NON-HVHZ EVALUATION FL5444-1113 CertainTeed As-,ltalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018 Page 5 of 13 NNEIVIO I etc. 6.6.1 Hip&Ridge for Arcadia'": Cedar CreStTM,Cedar Crest"IR Use two (2), minimum 1Y.-inch long fasteners per shingle. For the starter shingle, place fastener 1-inch from each side edge and about 2-inch up from the starter shingle's exposed butt edge, ensuring minimum %-inch embedment into the deck, or full penetration through the deck. For each full Cedar Crest shingle, place fasteners 8-5/8-inch up from its exposed butt edge and 1-inch from each side edge. For ASTM D3161,Class F performance use BASF"Sonolastic®NP1—"adhesive or Henkel "PL® Polyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements, to hand-seal Cedar Crest shingles. Apply NP 1 or PL adhesive from the middle of the shingle's raised overlay on the top piece and extending approximately 4-inch along the sides of the headlap along a line%to 1-inch from each side of the shingle's headlap. Immediately align and apply the overlying shingle,gently pressing tab sides into the adhesive,and install nails. To secure the other side,apply a 1-inch diameter spot of NP 1 or PL adhesive between the shingle layers. Nand-sealing adhesive (243 mm) (305 mMi 114" —4" ExA°s�'r° 3/4" 1" Dab of asphalt cement between shingle layers 6.7 BELIVIONTO OR BELMONT"'IR: Low and Standard Stope Steep Slope(greater than 21:12): (2:12 to 21:12): Use SEVEN nails and EIGHT spots of Use FIVE nails for every full Belmont shingle, asphalt roofing cement"'for every full located as shown below_ Belmont shingle.Apply asphalt roofing cement 1"(25mm)from edge of shingle. " , See below.Asphalt roofing cement meeting +--- 1 -1-Zoan) ASTM D4586 Type 11 is suggested_ f + St8'{16 mn) B Sm° t t3Z`( resn} orL J Lj less d Additional nals i rewwrei T�` T I S'B'illi�ranl 8568' (720 mm) Thy. �i i+ t°r25 m-) �------goofing CeseFad NEMO ETC,LLC Evaluation Report 3532.09.05-1114 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVH2 EVALUATION FL5444-1113 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018 Page 6 of 13 "ALI, IFT NEW I etc. 6.7.1 Hip&Ridge for Belmont®or Belmont'IR: 6.7.1.1 Option 1: For Belmont®, refer to instructions herein for Cedar Crest'"or Cedar Crests" IR hip and ridge shingles. For Belmont' IR, refer to instructions herein for Cedar Crest'" IR hip and ridge shingles. 6.7.1.2 Option 2: For Belmont®: Shangle®Ridge Exposure Remove tape 12" ',`�. J from the right side ' and fasten 8' SECOND Fasten theme,�' left side RIGHT Remove FIRST $5�8`J This Tape I LEFT Figure 17-19.'lnstadlation g fS6mfgle4 R e sbMgkts Figure 17-18.•Sbangte-Ridge, on hips and ridges, 6.7.1.3 For ASTM D3161,Class F performance use BASF"Sonolastic®NP11"'adhesive or Henkel "PL® Polyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements. 6.8 CARRIAGE HO .GRAND MANOR WW AND STEEP SLME STA!lLMR®SLOPE Use seven aids and three sprits of asphalt roofing cement for even full Grand Magor Shangle.Use fire nails and three spots of asphalt Use five nails for every full Shsngle, roofing etmott for every full.Carriage douse Shangle and Centennial Slate.Apply,asphalt rooting cement f"(25 mm)from edge of shingle (Figur 17.5).Asphalt roofing cement meeting V"t'M D1586 if 1„ ,) �., is suggested. _(25 mai) 1 ,n 38 5te" 85/8'• � forI m) t15 mm) (220 mm) 1 or sss 1• (25 mm) F5gure 17-4,Vse fivWdsforetwcv,ff'tll Grand ManorAWngle, 518 re' c4m&a Norse s&mgle,or C.entennud Slate. (16 mm)}1 (220 mm) (25 (25 mm)T L-- —=—Roofing Cement------- 13);w IT-5•Wten inskilling Grand.Manor Sbangles on steep sla1w, use wwo Halls and three tpou ofaspbtft ranfing towat. 6.8.1 Hip&Ridge for Carriage House Shangle®and Grand Manor Shangle: Refer to instructions herein for Shangle®Ridge hip and ridge shingles NEMO ETC,LLC Evaluation Report 3532.09.05-R14 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R13 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018 Page 7 of 13 ONEMOjetc. 6.9 LANDMARK", LANDMARK LANDMARK TI SOLARIS IR,NORTHGATE: LOW AND STANDARD SLOPE LANDMARK TL 131/2" 13" 131/2" METRIC DIMENSIONS --(343 mm)-----x(330 mm)-�--f-(343 mm) -1 12 143/4" 12' --i"(25 mm) 1' (25 mm) ►I j- (305 mm) x-(315 mm) +—(305 mm)-+{ 1 P5 n� ) Release lape 1'(25 mm) 1112"-_ ' --_ __ ___ . rA Nalable+ Area flaw 13.9:t efour mails,jor ereii full shine. NorthGate: MDE nAllP4 tr 14314' Ir AREA (305 mm) -+-.•—(375 mm) —+....—(305 mm) ��tmAlc r~ 1'(25 mm) t(25 mm}� NaGng artat for low and standard alopss(fr m 212 b 21:12) Nai rmflroe W ipper&lower s as~above. STEEP SLOPE Use sit nails and four spots of asphalt roofing cement for every full LANDMARK TL laminated shingle.see below.Asphalt roofing cement should meet A,,IUM D4586 Type 1L Apply t"spots of asph-ill roofing cement unde1311z`�- emh earner and at about 12"to 13"in from each edge. (343 mm) (330 mm) (343 mm) METRIC DIMENSIONS 'y-1"(25 rnm) 1"(25 aim)-•: I L• —12'- +-14314" 12"- r (305 mru) (375 mm) (305 mmp} (25 m m) � (25 mm) fifr t t . Reding CelmM I. 1 (25 n mj Release Tape 1"(25 mm)-�' Nail Arm For Steep - Figure 134:Use six nails mud four spots of ncp"t rrxftngceanenton stenp.4 pes. (25 mm) --- _ _ (25 mm; Roofing Cement NEMO ETC,LLC Evaluation Report 3532.09.05-R14 Certificate of Authorization#32455 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R13 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018 Page 8 of 13 "NEM0 etc. NorthGate: STEEP 12' 14-x14' 12' SLOE -x4305 mm)-.--.•—(375 mm)— +-(305 mm}--I NAILING AREA( -»- Nil ►as 1 (25 mm) m 1'(25 mm), .. Roofing Cemnt Nailing atreas for steep slopes(greater than 21:12) and"StomAailing" Nail between lower 2 nal Ines as shown above. 6.9.1 Hip&Ridge for Landmark'",Landmark'"IR,Landmark'"Pro,Landmark'" Premium Landmark'"TL Landmark'"Solaris,Landmark-Solaris IR,NorthGate: 6.9.1.1 Option 1: Shadow Ridge'"" or NothGate Accessory 12" (305mm) (250mm)� (150mm) ! (150mm) (125mm) (125mm) � ! f Notch for Notch for Centering Centering 12" r 18114" R ( 5mm) Notches for Alignment to (337mm) Notches for Alignment to _. the Top Edge of the Previous 7 the Top Edge of the Previous 75J8 Cap for 5`(125mm)Exposure(18�m) Capfor559"(141mm}Exposure (196mm) English Dimension Metric Dimension Shadow Ridge'"" Shadow Ridge'" 9 2713"1' —d2 0►run) 415+18(125 mm) 13 118" .4--(333 mm)- "►j Centering Plutch +-6 5.16" �165/8'. _ 168 moll 168 mm 13 t14' 1 (337 mitt) Atip thea f 1 Centering notow to top/ 7 13114" Noich ......_ X04 (194 Mill) (337 mm) \Align these notches to to 7 518` of P edge of (19I mm) previous course. NorthGate Ridge NorthGate Accessory NEMO ETC,LLC Evaluation Report 3532.09.05-R14 Certificate of Authorization#32455 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R13 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018 Page 9 of 13 NMEMO I etc. 00i;,) rK� •LayingNotch I 5vosuu5rn i tom' l r�f�fi f I Figure 1.3-20:Ilse laying notches to center shirWa on helps and ridges,and to locate the conrct exposum 6.9.1.2 For ASTM D3161, Class F performance use BASF "Sonolastic® NP1'""' adhesive or Henkel "PL® Polyurethane Roof&Flashing Sealant", in accordance with CertainTeed requirements. 6.9.1.3 Option 2: Refer to instructions herein for Cedar Crest'",Cedar Crest'"" IR hip and ridge shingles. 6.10 PRESIDENTIAL SHAKE'",PRESIDENTIAL SHAKE"IR,PRESIDENTIAL SHAKE TLm,PRESIDENTIAL SOLARIS'm: LOW AND STANDARD SLOPE: STEEP SLOPE: For low and standard slopes,use five nails for each full Presidential For steep slopes,use nine nails for each full Presidential shingle and shingle as shown below. apply l'diameter spots of asphalt roofing cement under each shingle tab. After applying 5 nails in between Ute nailing guide lines,apply 4 nails V Nailing I, 40' above tab cutouts maldng certain tabs of overlying shingle corer nails Guide Lines (1016 mm) 51/4 �— (133 mm) rN • . • • 141/4" 1 tr2''38 mm) (36�mm) • • • NOTE:Apply nails on painted guideline. Figure 16-6.•Fastening FiesidenA'rrl awd maiden tral T&3Gabe 1'diamelei asphalt roofing cement shingles on kw and standard slopws Figura 16-T Fas1mMg Prnvi&7Wal and Frewit -*hal W Sbakp shingim on stetp slopes. 6.10.1 Hip&Ridge for Presidential Shake'",,Presidential Shake'" IR Presidential Shake TL'"" Presidential Solaris'": 6.10.1.1 Option 1: Presidential Accessory PRESIDENTIAL ACCESSORY Presidential accessory shingles can be used for covering hips and ridges.Apply shingles up to the ridge(expose no more than 7"from the bottom edge of the "tooth."Fasten each accessory with two fas- teners.The fasteners must be 13/4" long or longer,so they penetrate either 3/4" into the deck or completely through the deck. Presidential accessory comes in two different sizes:Accessory produced in Birmingham,AL is 12'x 12';Portland,OR produces 97/8"x 131/4" accessory. 6.10.1.2 For ASTM D3161, Class F performance use BASF "Sonolastic® NP1'` adhesive or Henkel "PL® Polyurethane Roof&Flashing Sealant", in accordance with CertainTeed requirements. NEMO ETC,LLC Evaluation Report 3532.09.05-R14 Certificate of Authorization#32455 6'"EDITION(2017)FBC NON-HVHZ EVALUATION F1.5444-1113 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018 Page 10 of 13 WNEMOjetc. 6.10.1.3 Option 2: Refer to instructions herein for Cedar Crestrl,Cedar Crest—IR hip and ridge shingles. 6.11 HATTERASTI: STANM AND SW Std 9" (23 g„__> _y 1 (2�mmg tistttar) (2�mm) (230rnm) I �. g_. ..g• 8.._ . .�g••�� ( (234 mm) (230 min) ( i fo) {234 mm) I t.. i.. ={25mv 4. nrnj t25 rnM),/7,\ -2smm)- 4 3/8' Roofing Gement L mm) rrgam ri-d rrntrnl+tg..NadrCrws,4brn�cY on Stecsp, For steep dopm,nae like W16 and aigbt spar of ash>ialt roofing Figure M3:Fastening 11011 ras.10hoes an cement for rub full Halter sluagfe as sbaso abw.Apply I' Lola riWS1andard.54es (25otn).diamewr jms of roofingemstem(ASTM D i5"Type tt For low a xi,tanilard slopes,use five nails for each full suiested)under eaeh wh rorner,Press shb4t into Plate;do not Hatteras shingle as shown ahaw. expose cement. CAtfnOti:Tho murb roofing centrnt can rause sf bijb$to Muer. 6.11.1 Hip&Ridge for HatteraSTM: 6.11.1.1 Option 1: Accessory for Hatteras I =aSten bCth Sidi c t MWOMN Masan I I 1 2 Figure 15-14:TB three.piece units separate to make t 54 Hatteras Awessory shingles. 6.11.1.2 Option 2: Cut Hatteras Shingles T, {230 mm) I I i � Eos\ems (460 gQtti dSh,*,,11, til- - 460mm)Cap Capt cap Shingle Sh�''ngle Shi�,gle _ A�ZAO Figure 1_5-20.Gut Hatteras sl ngtes to macre c©yr cap• Figure 15-21:Ins Wiation of caps ahng hips and 644-c. 6.11.1.3 For ASTM D3161, Class F performance use BASF "Sonolastic" NPlr"' adhesive or Henkel "PL® Polyurethane Roof&Flashing Sealant", in accordance with CertainTeed requirements. NEMO ETC,LLC Evaluation Report 3532.09.05-1114 certificate of Authorizotion#32455 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-1113 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018 Page 11 of 13 NEMO I etc. 6.12 HIGHLAND SLATETm,HIGHLAND SLATE'm IR: Lida AND SUMMO$10P& STEEP SLOPE: _g e,— Use FIVE nails and FWM spots of asphalt roofing ccmenr for each paom q so.�y Izao. zte,. full tfighland Slate shingle.For Miand-Dade,SIX twits are required. 4pply I'diameter syots of asphalt roofing cement under each tab x ! vsmm) comer AThal I rocling cement meeting ASTM D458ti Type 11 is sugiested. ti--f.5wn+ pew; v�-orae reeurni �_ -i_- S1Xnaa(teora. �— +.nswiadovercentBr ..� aAM as Awl). Memi.Decb gyres ale- '� SU(nans(l nralc � �S mm) �cit "�' inelMwie,—to- 11 Flgarr 11.3:Use FIVE nails for e,*,H &aid SUM sbbigle. cvldrtM»"}. Roofing Cement Figure I!;3A:Use MIX rails and d gbt shots of acpbalt rooft eeammI under each tab corner. ^CAUTIOM Excessive Use of roofing cement can cause shingles to blister. 6.12.1 Hip&Ridge for Highland Slate TM,Highland Slate'"'IR: Refer to instructions herein for Cedar Crest'"',Cedar Crest'"' IR or Shangle RidgeT' hip and ridge shingles. 6.13 PATRIOT T": LOW AND STANDARD SLOPE STEEP SLOPE [w FOUR nails for every full shingle located as shown below. I sig F'OCR nails and four spots of asphalt roofing cement for every full shingle as shown below.Asphalt r(x)fing cement meeting A.fM D4586 Type If is suggested.Apply 1'(25 mm)spots of 2sphalt roofing sealant cement w shown. _ CALMON:Excessive use of roofing cetnent can cause shingles to blister. &tld' P-1 (25 man) 1 y V(2S mn;-a 156 mm) IT I — �� (3�tmm} GIs�net 13tfll �{ - . — —-—————— 6-tA I f155 mm)I•__ - q e T tR.eneO come" �- tzas —{— ��ix — tz•,s —I tnw4 (IM"M tl4rml 6.13.1 Hip & Ridge for PatriotTM Refer to instructions herein for Cedar CrestT"', Cedar Crest'" IR, Shadow Ridge T1, NorthGate or Shangle RidgeTm hip and ridge shingles. 7. LABELING: 7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. NEMO ETC,LLC Evaluation Report 3532.09.05-R14 Certificate of Authorization X32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R13 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018 Page 12 of 13 ONEMOjetc. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(414)248-6409; karen.buchmann@us.ul.com -END OF EVALUATION REPORT- NEMO ETC,LLC Evaluation Report 3532.09.05-1114 Certificate of Authorization#32455 6T'EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-1113 CertainTeed Asphalt Roof Shingles;(610)6S3-5847 Revision 14:01/24/2018 Page 13 of 13