Loading...
HomeMy WebLinkAboutProduct Approval Product Conformance to 6th Edition (2017) Florida Building Code Rule 61G20-3 F.A.C. I Project No. 418-0102 ( 1/8/18 ) Page 1 of 2 Product Manufacturer Product Name, Model and/or Description Maxim Industries, Inc. Dade Curb Mount Skylight Polycarbonate Glazed Aluminum Skylight 1630 Terre Colony Court Dade Self Flashing Skylight Polycarbonate Glazed Aluminum Skylight Dallas,TX 75212 Florida Product Approval No.: FL2418 th Code: 6 Edition(2017)Florida Building Code Compliance Method: • Product Approval Rule 61G20-3.007(1)(f)—Self-Affirmation • Product Approval Rule 61G20-3.005(1)(d)—Product Evaluation Report by a Licensed Professional Engineer • Product Approval Rule 61G20-3.015(4)(d)—Equivalency of Standards • Product Approval Rule 61G20-3.005(1)(e)—project specific approval by the local authorities having jurisdiction in accordance with alternate methods and materials authorized in the Code(Section 104.11) Code Conformance Review: The undersigned has reviewed the above referenced Florida Product Approval and associated documents and found all drawings,reports,referenced test standards,and testing as noted in the approved documents to be in compliance with the 6th Edition(2017)Florida Building Code. It has been concluded that no revisions or changes to the referenced standards have occurred between the following(where applicable)that affect the results of design,testing or engineering of the approved product(s). • Chapter 35 of the 5th Edition(2014)Florida Building Code compared to Chapter 35 of the 611 Edition(2017)Florida Building Code • Chapter 46 of the 5th Edition(2014)Florida Residential Code compared to Chapter 46 of the 6'Edition(2017)Florida Residential Code • Test Protocols for HVHZ/51h Edition(2014)Florida Building Code compared to Test Protocols for HVHZ/6th Edition (2017) Florida Building Code,specifically the following where applicable. o TAS 201-94,TAS 202-94 and TAS 203-94 Conformance Review of skylight glazing material Manufacturer(s)and Component Approval per Miami-Dade NOA: • The currently issued Miami-Dade NOA for component approval to the Florida Building Code for Covestro,LLC Makrolon Polycarbonate Sheets was reviewed and found to be in compliance with the 6th Edition(2017)Florida Building Code.Covestro,LLC Miami-Dade NOAs can be found here. Therefore,all test standards used in testing and all design standards used in design and engineering of the currently approved product(s)remain valid for compliance to the 6th Edition(2017)of the Florida Building Code. Certification Agency Certificate(attached) • N1009198-135,Expiration 12/31/21 for Dade Self Flashing Skylight • N1009198.01-R5,Expiration 12/31/21 for Dade Curb Mount Skylight Installation Instructions(available from Product Manufacturer) • Drawing No.DSF1507,Dated 7/10/15,signed&sealed by T.Berman,P.E. • Drawing No.DCM1507,Dated 7/10/15,signed&sealed by T.Berman,P.E. PTC Product Design Group, LLC I PO Box 520775 1 Longwood, FL 32752-0775 /W/L 321-690-1788 1 FBPE Certification of Authorization No. 25935 Product Conformance to 6th Edition (2017) Florida Building Code Rule 61G20-3 F.A.C. I Project No. 418-0102 1 1/8/18 1 Page 2 of 2 Certificate of In epe dente per Product Approval ..MES 4",. .••..:���•,, Digitally signed E JV s4P ;0 b Robert ) PTC Product Design Group,LLC and Robert J.Amoruso,P.E. ? N 49752 :O y does not have,nor will acquire,any financial interest in the = * _ Amoruso company manufacturing or distributing products)covered ��O C�� by this Product Evaluation Report. �:� STR G OF ��� :Date: 2018.01 .08 R PTC Product Design Group,LLC and Robert J.Amoruso,P.E. ��SS/O ` ?, 1 6:55:50 —0500� do not have,nor will acquire any financial interest in any NA �� other entity involved in the approval process or testing of Evaluated by: the product(s)covered by this Product Evaluation Report. Robert J.Amoruso,P.E. FL P.E.License No.49752 ...ss PTC Product Design Group, LLC I PO Box 520775 1 Longwood, FL 32752-0775 r/ii 321-690-1788 1 FBPE Certification of Authorization No. 25935 NOTICE OF PRODUCT CERTIFICATION CERTIFICATION NO: NI009198-115 DATE: 12/30/2007 CERTIFICATION PROGRAM: Structural COMPANY: Maxim CODE: M-1256-1 REVISION DATE: 08/21/2017 To verify that the"Notice of Product Certification"is valid,please visit www.NANIICertification.com to assure that the product is active and currently listed.This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NANH if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION Maxim Industries,Inc. Series"Dade Self-Flashing" 1630 Terre Colony Court Polycarbonate Glazed Aluminum Skylight Dallas,Texas 75212 Configuration:0 Glazing:Exterior Dome-0.118"Hyzod Polycarbonate w/8"rise/Interior Dome-0.118"Hyzod Polycarbonate w/4"rise Overall: W-4'6" DLO: W-39" 1.146" H-719" SPECIFICATION PRODUCT RATING TAS 201/202/203-94 Design Pressure: +60/-60 psf Large Missile Impact Rated Product Tested By: Architectural Testing,Inc. Report No: ATI-01-43381.01 Expiration Date: December 31,2021 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes,VA 23072 Tel:(804)684-5124 Fax: (804)684-5122 • • Certificate of Participation Is Hereby Granted to: Solatube International, Inc. 2210 Oak Ridge Way Vista, California 92081-8341 To attest the manufacturer is a licensed participant in the Keystone Quality Assurance Program Licensee No: 0110 Scope of Licensure: FPA Expires: 04/25/2022 - Granted: 02/07/2018 KEYST01 CERTIFICATIONS. Ongoing program licensure may be verified at Jon Hill, President www.keystonecerts.com SCIS Home I Log In User Registration Hot Topics I Submit Surcharge i Stats&Facts Publications FBC Staff I SCIS Site Map Unks i Search j ;;'�Product Approval -= - USER:Public User db'pr Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL11480-R11 Application Type Revision Code Version 2017 Application Status Pending FBC Approval Comments Archived ❑ Product Manufacturer Solatube International,Inc Address/Phone/Email 2210 Oak Ridge Way Vista,CA 92081 (760)597-4427 tanderson@solatube.com Authorized Signature Todd Anderson tanderson@solatube.com Technical Representative Todd Anderson Address/Phone/Email 2210 Oak Ridge Way Vista,CA 92081 (760)597-4427 tanderson@solatube.com Quality Assurance Representative Address/Phone/Email Category Sky Lights Subcategory Skylight Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert].Amoruso,P.E. the Evaluation Report Florida License PE-49752 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 04/25/2022 Validated By Steven M.Urich,PE E Validation Checklist-Hardcopy Received Certificate of Independence FL11480 RI1 COI CI 417-0905 SolatubeSkylicihts ss.Ddf Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA 101/I.S.2/A440 2011 ASTM E1886 2005 ASTM E1996-2012a 2012 ASTM E283 2004 ASTM E330 2002 ASTM E331-00(2009) 2009 TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL11480 R11 Eauiv EER 1971 Rev5 417-0905 SOLA0004- SOLA0013 ss.pdf FL11480 RS1 Eauiv EER 1973 Rev4 SOLA0005 ss.odf FL11480 R11 Eauiv EER 2167 Rev4 SOLA0008 ss.pdf FL11480 R11 Eauiv EER 2396 Rev2 M74 DS Curb Mount Open Ceiling ss.pdf FL11480 R11 Eauiv EER 2397 Rev2 M74 DS Curb Mount with Amplifier ss.pdf FL11480 R11 Eauiv EER 2399 Rev2 Solatube 160 290 DS TDD ss.vdf FL11480 R11 Eauiv EER 2400 Rev2 Solatube 330DS 750 DS TDD ss.ILdf Sections from the Code Product Approval Method Method 1 Option D Date Submitted 02/07/2018 Date Validated 02/07/2018 Date Pending FBC Approval 02/15/2018 Summary of Products FL# Model,Number or Name Description 11480.1 160 DS TDD Impact 160 DS(10")Tubular Daylight Device-HVHZ Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11480 R11 II SOLA0004 RevE 160DS-29ODS ss.pdf Approved for use outside HVHZ:Yes Verified By: Robert J.Amoruso,P.E.FL License No.49752 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: +70/-70 Evaluation Reports Other: FL11480 R11 AE PER 1971 Rev5 417-0905 SOLA0004- SOLA0013 ss.pdf Created by Independent Third Party:Yes 11480.2 160 DS TDD Non-Impact 160 DS(10")Tubular Daylight Device-Non- HVHZ Limits of Use Installation Instructions Approved for use in HVHZ:No FL11480 R11 II Model 160 DS TDD-Product Drawing Approved for use outside HVHZ:Yes Packaae.pdf Impact Resistant:No Verified By: Robert].Amoruso,PE FL PE No.49752 Design Pressure:+70/-70 Created by Independent Third Party:Yes Other: Evaluation Reports FL11480 R11 AE PER 2399 Rev2 Solatube 160 DS-290 DS TDD ss.pdf Created by Independent Third Party:Yes 11480.3 290 DS TDD Non-Impact 290 DS(14")Tubular Daylight Device-Non- HVHZ Limits of Use Installation Instructions Approved for use in HVHZ:No FL11480 R11 II Model 290 DS TDD-Product Drawina Approved for use outside HVHZ:Yes Packaoe.pdf Impact Resistant:No Verified By: Robert J.Amoruso,PE FL PE No.49752 Design Pressure: +70/-70 Created by Independent Third Party:Yes Other: Evaluation Reports FL11480 R11 AE PER 2399 Rev2 Solatube 160 DS-290 DS TDD ss.pdf Created by Independent Third Party:Yes 11480.4 290 DS TDD Impact 290 DS(14")Tubular Daylight Device-HVHZ Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11480 R11 II SOLA0004 RevE 160DS-29ODS ss.pdf Approved for use outside HVHZ:Yes Verified By: Robert J.Amoruso,P.E. FL License No.49752 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: +70/-70 Evaluation Reports Other: FL11480 R11 AE PER 1971 Rev5 417-0905 SOLA0004- SOI-A0013 ss.pdf Created by Independent Third Party:Yes 11480.5 300 DS TDD Impact 300 DS(14'0 Tubular Daylight Device-HVHZ Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11480 R11 II 300 DS SKYLIGHT-MANUFACTURERS Approved for use outside HVHZ:Yes INSTALLATION DETAIL PACKAGE.Ddf Impact Resistant:Yes FL11480 RSI II SOLA0013 RevO 30ODS ss.Ddf Design Pressure:+70/-70 Verified By: Robert J.Amoruso,PE FL PE No.49752 Other: Created by Independent Third Party:Yes Evaluation Reports FL11480 R11 AE PER 1971 RevS 417-0905 SOLA0004- SOLA0013 ss.Ddf Created by Independent Third Party: Yes 11480.6 330 DS TDD Non-Impact 330 DS(21")Tubular Daylight Device-Non- HVHZ Limits of Use Installation Instructions Approved for use in HVHZ:No FL11480 R11 II Model 330 DS TDD-Product Drawing Approved for use outside HVHZ:Yes Package.Ddf Impact Resistant:No Verified By: Robert].Amoruso,PE FL PE No.49752 Design Pressure:+70/-70 Created by Independent Third Party:Yes Other: Evaluation Reports FL11480 R11 AE PER 2400 Rev2 Solatube 330DS 750 DS TDD ss.Ddf Created by Independent Third Party:Yes 11480.7 750 DS TDD Non-Impact 750 DS(21")Tubular Daylight Device-Non- HVHZ Limits of Use Installation Instructions Approved for use in HVHZ:No FLIX480 R11 II Model 750 DS TDD-Product Drawing Approved for use outside HVHZ:Yes Package.Ddf Impact Resistant:No Verified By: Robert J.Amoruso,PE FL PE No.49752 Design Pressure: +70/-70 Created by Independent Third Party:Yes Other: Evaluation Reports FL11480 R11 AE PER 2400 Rev2 Solatube 33ODS 750 DS TDD ss.Ddf Created by Independent Third Party:Yes 11480.8 750 DS TDD Impact 750 DS(21")Tubular Daylight Device-HVHZ Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11480 R11 II SOLA0005 RevD 75ODS ss.Ddf Approved for use outside HVHZ:Yes Verified By: Robert].Amoruso,P.E. FL License No.49752 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:+70/-70 Evaluation Reports Other: FL11480 R11 AE PER 1973 Rev4 SOLA0005 ss.Ddf Created by Independent Third Party:Yes 11480.9 Smart LED Smart LED 10"Tubular Daylight Device-HVHZ Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11480 R11 II SOLA0008 RevC ss.Ddf Approved for use outside HVHZ:Yes Verified By: Robert].Amoruso,P.E.49752 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:+70/-70 Evaluation Reports Other: FL11480 R11 AE PER 2167 Rev4 SOLA0008 ss.Ddf Created by Independent Third Party:Yes 11480.10 Solatube M74 DS Curb Mount Open Solatube M74 DS Curb Mount Open Ceiling TDD-Dual Ceiling TDD Glazed-HVHZ Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11480 R11 II M74 DS-0-DPP-FC-B-L2-REG FBC- Approved for use outside HVHZ:Yes PER2396 ss.Ddf Impact Resistant:Yes Verified By: Robert].Amoruso,P.E. FL License No.49752 Design Pressure:+80/-80 Created by Independent Third Party:Yes Other: Evaluation Reports FL11480 R11 AE PER 2396 Rev2 M74 DS Curb Mount Open Ceiling ss.Ddf Created by Independent Third Party:Yes 11480.11 Solatube M74 DS Curb Mount Open Solatube M74 DS Curb Mount Open Ceiling TDD-Single Ceiling TDD Glazed-HVHZ Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11480 R11 II M74 DS-0-DP-FC-B-L2-REG FBC- Approved for use outside HVHZ:Yes PER2396 ss.pdf Impact Resistant:Yes Verified By: Robert J.Amoruso,P.E.FL License No.49752 Design Pressure:+80/-80 Created by Independent Third Party:Yes Other: Evaluation Reports FL11480 R11 AE PER 2396 Rev2 M74 DS Curb Mount Open Ceiling ss.pdf Created by Independent Third Party:Yes 11480.12 Solatube M74 DS Curb Mount Open Solatube M74 DS Curb Mount Open Ceiling TDD with Ceiling TDD with Amplifier Amplifier-Dual Glazed-HVHZ Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11480 R11 II M74 DS-0-DPP-FC-A-L2-REG FBC- Approved for use outside HVHZ:Yes PER2397 ss.pdf Impact Resistant:Yes Verified By: Robert J.Amoruso,P.E. FL PE No.49752 Design Pressure:+80/-80 Created by Independent Third Party:Yes Other: Evaluation Reports FL11480 R11 AE PER 2397 Rev2 M74 DS Curb Mount with Amplifier ss.pdf Created by Independent Third Party: Yes 11480.13 Solatube M74 DS Curb Mount Open Solatube M74 DS Curb Mount Open Ceiling TDD with Ceiling TDD with Amplifier Amplifier-Single Glazed-HVHZ Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11480 R11 II M74 DS-O-DP-FC-A-L2-REG FBC- Approved for use outside HVHZ:Yes PER2397 ss,DddF Impact Resistant:Yes Verified By: Robert 1.Amoruso,P.E. FL PE No.49752 Design Pressure:+80/-80 Created by Independent Third Party:Yes Other: Evaluation Reports FL11480 Rii AE PER 2397 Rev2 M74 DS Curb Mount with Amplifier ss.pdf Created by Independent Third Party:Yes Beck Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyrieht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your a-mall address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: FWEM W RW eCh i Credit Card Safe ArFsaL. Product Evaluation Report Date: February 7, 2018 PTC Report No.: 1971 Report Revision No.: 5 PTC Project No.: 417-0905 Product Mfg.: Solatube International, Inc. 2210 Oak Ridge Way Vista, CA 92081 Product Name: Impact 160 DS(10"),290 DS(14") &300 DS(14")Tubular Daylight Device-HVHZ Product Category: Sky Lights Product Sub-Category: Skylight Compliance Method: Product Approval Rule 61G20-3.005(1)(d)—Product Evaluation Report by a Licensed Professional Engineer Prepared By: Robert J.Amoruso, P.E. Florida P.E. License Number 49752 PTC Product Design Group, LLC FBPE Certification of Authorization No.25935 CERTIFICATE OF INDEPENDENCE ,gi A�aM..S 4 joDigitally signed . :,,.GENSF. , � by Robert J N 49752 �O. i PTC Product Design Group,LLC and Robert J.Amoruso, P.E.do not have,norwill acquire,anyfinancial interest _�• �4 Amoruso in the company manufacturing or distributing STA E OF .'tui - '° w, --pDate2018.02.07 product(s) covered by this Product Evaluation Report. '%'��c:-%<O R�oP:N2�.` "'ss�•��•••••�• ��� 09.24:59 -05'00' PTC Product Design Group,LLC and Robert J.Amoruso, iia,'ONAli it P.E.do not have, nor will acquire any financial interest in any other entity involved in the approval process or Evaluated by: testing of the product(s) covered by this Product Robert J.Amoruso, P.E. Evaluation Report. Florida P.E. License Number 49752 PTC Product Design Group, LLC Project No.417-0905 Page 1 PO Box 520775 Report No. 1971, Rev. 5 Longwood, FL 32752-0775 Phone:321-690-1788 Fax:321-690-1789 FBPE Certification of Authorization No. 25935 Project Scope Evaluate Solatube Impact 160 DS(10"),290 DS(14") &300 DS(14")Tubular Daylight Device for conformance to the Current Edition of the Florida Building Code—Building and Residential Volumes including the High Velocity Hurricane Zone(HVHZ). Prepare the following: • Product Installation Details/Drawings (Reference 1) • Installation Anchorage Evaluation (Reference 3) • Product Evaluation Report(this report) Description of Product — Installation Requirements See Reference 1 for a description of the product, its installation and other pertinent data related to its approved use. Limitations and Conditions of Use This product evaluation report contains or makes reference to specifications,technical details and installation details and/or methods that pertain to the proper use and/or installation of the product specified herein. Specific limitations and conditions of its use including but-not limited to the following are contained in Reference 1 and are the subject of Product Approval in accordance with the State of Florida Product Approval Rule 61G20- 3. • Design Pressure Rating(psf) • Installation restrictions. • Installation substrate requirements. • Product description. • Installation anchor requirements. • Product components. Quality Assurance This product is manufactured under a quality assurance program audited by an approved Certification and Quality Assurance Entity Keystone Certifications Inc. (KCI) as required in Rule 61G20-3.005(3).See FBC Organization No. CER1523 and QUA1824 for approval under Rule 61G20-3. PTC Product Design Group, LLC Project No.417-0905 Page 12 PO Box 520775 Report No. 1971, Rev. 5 Longwood, FL 32752-0775 Phone:321-690-1788 Fax:321-690-1789 FBPE Certification of Authorization No.25935 Code Conformance — Performance Testing Reference 2.a conducted testing to the following standard(s).See Reference 3.b for Code Conformance Evaluation to the Current Edition FBC for these testing standards. 1) TAS 201-94-Impact Test Procedures 2) TAS 202-94-Criteria for Testing Impact& Nonimpact Resistant Building Envelope Components Using Uniform Static Air Pressure 3) TAS 203-94-Criteria for Testing Products Subject to Cyclic Wind Pressure Loading DESIGN PRESSURE LIMITATIONS • From Reference 2.a o Uniform Load Structural Test Pressures where+210/-140 psf. o Water Test Pressure of+10.5 psf. o Cyclic Wind Loading Pressure of+/-70 psf. • Apply the following factors to arrive at Design Pressure. o A Safety Factor of 2 applied to the Uniform Load Structural Test Pressures to arrive at Design Pressures of+105/-70 psf. o A factor of 1/0.15=6.67 applied to the Water Test Pressure arrive at Design Pressures of+70 psf. • Overall Design Pressure is+/-70 psf. Code Conformance — Plastics The Current Edition Florida Building Code, Chapter 26 define requirements for Approved Plastics.The following table summarizes plastics testing for applicable components. See Reference 3.b for Code Conformance Evaluation to the Current Edition FBC for the testing standards mentioned below. BOM Item No. in parenthesis refer to drawing number SOLA0004 and SOLA0013 unless otherwise indicated. OUTER DOME(1),DOME RING (3),TOP TUBE CLIP(7)AND INNER DOME(26 on SOLA0004 and 27 on SOLA0013)testing for High Impact Acrylic PMMA(Poly(methyl methacrylate)) Attribute Report ASTM Result Acceptance Reference Criteria Outdoor 2.b.i ASTM G155-05a 9.25% +/-10% Exposure and D638-03 difference in tensile strength Rate of Burning 2.b.ii ASTM D635-06 CC2 CC1 or CC2 Self-Ignition 2.b.iii ASTM D1929-96 982°F >650°F Temperature Smoke Density 2.b.iv ASTM E84-06 400 <450 Conclusion:ACCEPTABLE PTC Product Design Group, LLC Project No.417-0905 Page 13 PO Box 520775 Report No. 1971, Rev. 5 Longwood, FL 32752-0775 Phone:321-690-1788 Fax:321-690-1789 FBPE Certification of Authorization No. 25935 OUTER DOME(1),DOME RING (3),TOP TUBE CLIP(7)AND INNER DOME(26 on SOLA0004 and 27 on SOLA0013)testing for High Impact Acrylic PMMA(Poly(methyl methacrylate)) Attribute Report ASTM Result Acceptance Reference Criteria Outdoor 2.c.i ASTM G155- 3.3% +/- 10% Exposure 00ae1 and difference in D638-03 tensile strength Rate of Burning 2.c.ii ASTM D635-06 CCI CCI or CC2 Self-Ignition 2.c.iii ASTM D1929- 930°F >650°F Temperature 96(2001)e1 Smoke Density 2.c.iv ASTM D2843-99 5.8 <75 Conclusion:ACCEPTABLE EFFECT LENS(17)testing for PET-GAG (PET-Polyethylene Terephthalate, High Frequency Welding Grade- GAG) Attribute Report ASTM Result Acceptance Reference Criteria Rate of Burning 2.d.ii ASTM D635-06 CC1 CC1 or CC2 Self-Ignition 2.d.iii ASTM D1929- 765°F >650°F Temperature 96(2001)e1 Smoke Density 2.d.iv ASTM E84-09a 95 <450 Conclusion:ACCEPTABLE CEILING RING (16)AND DRESS RING (19)testing for Medium Impact Acrylic PMMA(Poly(methyl methacrylate)) Attribute Report ASTM Result Acceptance Reference Criteria Outdoor 2.e.iv ASTM G155-05a 9.25% +/-10% Exposure and D638-03 difference in tensile strength Rate of Burning 2.e.i ASTM D635-06 CC2 CC1 or CC2 Self-Ignition 2.e.ii ASTM D1929-96 982°F >650°F Temperature Smoke Density 2.e.iii ASTM E84-06 400 <450 Conclusion:ACCEPTABLE PTC Product Design Group, LLC Project No.417-0905 Page 14 PO Box 520775 Report No. 1971, Rev. 5 Longwood, FL 32752-0775 Phone:321-690-1788 Fax:321-690-1789 FBPE Certification of Authorization No.25935 CEILING RING (16)AND DRESS RING(19)testing for Medium Impact Acrylic PMMA(Poly(methyl methacrylate)) Attribute Report ICC-ES Report Result Acceptance Comment Reference Criteria Rate of Burning 2.f.i &2.f.ii ICC-ES ER-1084 CC2 CCI or CC2 IBC-2606 has Self-Ignition 2.f.i &2.f.ii and ESR-1653 Conformance >650°F same Temperature per ICC-ES ER- requirements as Smoke Density 2.f.1 &2.f.ii 1084 and ESR- <450 Current Edition 1653 FBC, Chapter 26 Conclusion:ACCEPTABLE DIFFUSER PANEL(18)testing for Medium Impact Acrylic PMMA(Poly(methyl methacrylate)) Attribute Report ASTM Result Acceptance Reference Criteria Rate of Burning 2.g.i ASTM D635-06 CC2 CC1 or CC2 Self-Ignition 2.g.ii ASTM D1929-96 992°F >650°F Temperature Smoke Density 2.g.iii ASTM E84-06 350 <450 Conclusion:ACCEPTABLE DIFFUSER PANEL(18)testing for Polycarbonate Sheet Attribute Report ASTM Result Acceptance Reference Criteria Rate of Burning 2.h.i ASTM D635-74 CC2 CCI or CC2 Self-Ignition 2.h.ii ASTM D1929- 896°F >650°F Temperature 68(1975) Smoke Density 2.h.iii ASTM D2843-93 38 <75 Conclusion:ACCEPTABLE ACRYLIC LENS AND TRIM RING (Various—BOM—Optional Diffusers on SOLA0004)testing for Acrylic Attribute Report ASTM Result Acceptance Reference Criteria Rate of Burning 2.i.i ASTM D635-14 CC2 CCI or CC2 Self-Ignition 2.i.i ASTM D1929-16 878°F >650°F Temperature Smoke Density 2.i.i ASTM D2843-16 13.4 <75 Conclusion:ACCEPTABLE PTC Product Design Group, LLC Project No.417-0905 Page 15 PO Box 520775 Report No. 1971, Rev.5 Longwood, FL 32752-0775 Phone:321-690-1788 Fax:321-690-1789 FBPE Certification of Authorization No. 25935 Performance and Testing Standards Reference 2.a conducted air,water and structural testing including impact and cyclic loading to the following standard(s). 1) TAS 201-94-Impact Test Procedures 2) TAS 202-94-Criteria for Testing Impact& Nonimpact Resistant Building Envelope Components Using Uniform Static Air Pressure 3) TAS 203-94-Criteria for Testing Products Subject to Cyclic Wind Pressure Loading Reference 2.b,2.c, 2.d,2.e,2.g,2.h and 2.i conducted plastics testing to the following standard(s). 1) ASTM G155-05a,Standard Practice for Operating Xenon Arc Light Apparatus for Exposure of Non- Metallic Materials 2) ASTM G155-OOae1,Standard Practice for Operating Xenon Arc Light Apparatus for Exposure of Non- Metallic Materials 3) ASTM D638-03,Standard Test Method for Tensile Properties of Plastics 4) ASTM D635-06,Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position. 5) ASTM D635-74,Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position. 6) ASTM D1929-96(2001)e1,Standard Test Method for Determining Ignition Temperature of Plastics. 7) ASTM D1929-96,Standard Test Method for Determining Ignition Temperature of Plastics. 8) ASTM D1929-68(1975),Standard Test Method for Determining Ignition Temperature of Plastics. 9) ASTM E84-06,Standard Test Method for Surface Burning Characteristics of Building Materials 10) ASTM E84-09a,Standard Test Method for Surface Burning Characteristics of Building Materials 11) ASTM D 2843-99,Standard Test Method for Density of Smoke from the Burning or Decomposition of Plastics. 12) ASTM D 2843-93,Standard Test Method for Density of Smoke from the Burning or Decomposition of Plastics. 13) ASTM D635-14,Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position 14) ASTM D1929-16,Standard Test Method for Determining Ignition Temperature of Plastics 15) ASTM D2843-16,Standard Test Method for Density of Smoke from the Burning or Decomposition of Plastics Reference 2.f recorded ICC/FBC conforming plastics testing in the following evaluation reports. 1) ICC-ES Report No. ER-1084 2) ICC-ES Report No. ESR-1635 PTC Product Design Group, LLC Project No.417-0905 Page 16 PO Box 520775 Report No. 1971, Rev. 5 Longwood, FL 32752-0775 Phone:321-690-1788 Fax:321-690-1789 FBPE Certification of Authorization No. 25935 References and Supporting Documents 1) Drawings a. SOLA0004, Rev. E,dated 10/17/17,signed and sealed by Robert J.Amoruso, PE,Solatube Impact 160 DS(10")and 290 DS(14") Tubular Daylight Device-Installation Anchorage Details. b. SOLA0013,Original Issue, dated 10/17/17,signed and sealed by Robert J.Amoruso, PE,Solatube Impact 300 DS(14")Tubular Daylight Device-Installation Anchorage Details. 2 Testingnote that References 2.b thru 2.h have the BOM Item description and Item No. shown. ( P ( ) a. Architectural Testing Inc.Test Report No.85320.01-301-18,dated 9/08/08,Solatube Impact 160 DS(10")and 290 DS(14")Tubular Daylight Device testing to TAS 201, TAS 202 and TAS 203, signed and sealed by Joshua M. Royce, P.E. i. 300 DS(14")Tubular Daylight Device same as 290 DS for exterior skylight components. Therefore,Test Report No.85320.01-301-18 applicable. b. OUTER DOME(1), DOME RING (3),TOP TUBE CLIP (7)AND INNER DOME (26)testing for High Impact Acrylic PMMA(Poly(methyl methacrylate)) i. Intertek Test Report No.3143957-004,dated 9/24/08,testing to ASTM G155-05a and D638-08 in accordance with ASTM D2565-99. ii. SGS Test Report No. 177:013002-01-R1,dated 6/10/08,testing to ASTM D635-06. iii. SGS Test Report No. 177:013002-02-R1, dated 6/10/08,testing to ASTM D1929-96. iv. SWRI Test Report No.01.12693.01.139,dated 4/5/07,testing to ASTM E84-06. c. OUTER DOME(1), DOME RING (3),TOP TUBE CLIP (7)AND INNER DOME(26)testing for High Impact Acrylic PMMA(Poly(methyl methacrylate)) i. Architectural Testing Inc.Test Report No. 58735.01-106-18, dated 1/4/07,testing to ASTM G155-OOae1 and D638-03. ii. SGS Test Report No. 177:002666-03,dated 1/2/07,testing to ASTM D635-06. iii. SGS Test Report No. 177:002666-01,dated 1/13/07,testing to ASTM D1929-96(2001)e1. iv. SGS Test Report No. 177:002666-02,dated 1/2/07,testing to ASTM D2843-99. d. EFFECT LENS(17), PET-GAG (PET-Polyethylene Terephthalate, High Frequency Welding Grade- GAG)testing i. SGS Test Report No.2138368-1, dated 8/27/10,testing to ASTM D635-06. ii. SGS Test Report No. 2138368-3,dated 2/2/10,testing to ASTM D1929-96(2001)e1. iii. SGS Test Report No. 2138368-2,dated 8/31/10,testing to ASTM E84-09a. e. CEILING RING (16)AND DRESS RING (19)testing for Medium Impact Acrylic PMMA(Poly(methyl methacrylate)) L SGS Test Report No. 177:013002-01-R1,dated 6/10/08,testing to ASTM D635-06. ii. SGS Test Report No. 177:013002-02-R1,dated 6/10/08,testing to ASTM D1929-96. iii. SWRI Test Report No.01.12693.01.139,dated 4/5/07,testing to ASTM E84-06. PTC Product Design Group, LLC Project No.417-0905 Page 17 PO Box 520775 Report No. 1971, Rev. 5 Longwood, FL 32752-0775 Phone:321-690-1788 Fax:321-690-1789 FBPE Certification of Authorization No. 25935 iv. Intertek Test Report No.3143957-004, dated 9/24/08,testing to ASTM G155-05a and D638-08 in accordance with ASTM D2565-99. f. CEILING RING (16)AND DRESS RING (19)testing for Medium Impact Acrylic PMMA(Poly(methyl methacrylate)) i. ICC-ES Report No. ER-1084 demonstrates compliance to I-Codes for use in skylight applications. Report No. ER-1084 and Current Edition FBC requirements same based on review of documented results. ii. ICC-ES Report No. ESR-1635 demonstrates compliance to I-Codes for use in skylight applications. Report No. ESR-1635 and Current Edition FBC requirements same based on review of documented results. g. DIFFUSER PANEL(18)testing for Medium Impact Acrylic PMMA(Poly(methyl methacrylate)) i. SGS Test Report No. 177:013002-03-R1,dated 6/10/08,testing to ASTM D635-06. ii. SGS Test Report No. 177:013002-04-R1,dated 6/10/08,testing to ASTM D1929-96. iii. SWRI Test Report No.01.13536.01.060,dated 1/30/08,testing to ASTM E84-06. h. DIFFUSER PANEL(18)testing for Polycarbonate i. SGS Test Report No. 153367-2,dated 4/2/01,testing to ASTM D635-74. ii. SGS Test Report No. 153367-1,dated 4/2/01,testing to ASTM D1929-68(1975). iii. SGS Test Report No. 153367-3,dated 4/2/01,testing to ASTM D2843-93. L Acrylic Lens and Trim Ring(Various in BOM of Optional Diffusers)testing for Acrylic Material i. Intertek/ATI Test Report No. G3786.01-106-24, dated 4/28/17 for Huashuaite Clear Acrylic Sheet Material 3) Reports a. Engineering Analysis:Anchorage and product verification has been substantiated by calculation prepared,signed and sealed by Robert J.Amoruso, P.E. in accordance with the current edition of the Florida Building Code. b. PTC Report No. 1971-EER, Rev.5,Solatube Impact 160 DS(10"),290 DS(14")and 300 DS(14") Tubular Daylight Device—Referenced Testing Standards Equivalency Evaluation, dated 2/7/18, signed and sealed by Robert J.Amoruso, P.E. PTC Product Design Group, LLC Project No.417-0905 Page 18 PO Box 520775 Report No. 1971, Rev. 5 Longwood, FL 32752-0775 Phone:321-690-1788 Fax:321-690-1789 FBPE Certification of Authorization No. 25935 la #ed gaz,;,� Solatube Daylighting System Thermal Performance Characteristics SOLA'6lA... Who A.0' R, jorfj � .uC _ '_.. �.-.', F- ...,i� a. _. 9S}: „3„13.+w ve`ivual.:.a,_!.,1,$, _ ..� rd� ,• Iiiik Solatube 160 DS(10 iN250 mm)and 290 VusionTM 0.61 1.64 0.27 Cert.*3762 10"insulation @ceiling,30"tube length&dual glazed diffuser. DS 14 in/350 mm Solatube 160 DS(10 10"insulation @ ceiling,30"tube length&dual glazed diffuser in/250 mm)and 290 VusionTM 0.61 1.64 0.23 Cert#3762 DS 14 in/350 mm with Softening Effect Lens. Solatube 160 DS(10 in/250 mm)and 290 OptiVlew® 0.61 1.64 0.27 Cert.#3762 10"insulation @ ceiling,30"tube length&dual glazed diffuser. DS 14 in/350 mm Solatube 160 DS(10 in/250 mm)and 290 JustFrostTM 0.60 1.67 0.27 Cert.#3762 10"insulation @ ceiling,30"tube length&dual glazed diffuser. DS 14 in/350 mm Solatube 160 DSe(10 IN250 mm)and 290 VusionTM 0.46 2.17 0.20 Cert.#6030 10"insulation @ ceiling,30"tube length&dual glazed diffuser. DSe(14 in/350 mm) Solatube Smart LED JustFrostTM 0.52 1.92 0.16 Cert#9020 10"insulation @ ceiling,30"tube length&dual glazed diffuser. Solatube i 330 DS-C (21in/530 mm) Prismatic 0.51 1.96 0.34 Cert.#5006 10"insulation @ ceiling,30"tube length,single glazed dome,and (21 -Suspended Ceilina dual glazed transition box Solatube 330 DS-C 10"insulation @ ceiling,30"tube length,single glazed dome,and (21 in/530 mm) OptMew® 0.51 1.96 0.32 Cert.#5006 Sus ended Ceilino dual glazed transition box Solatube 750 DS-C (21 in/530 mm) Prismatic 0.51, 1.96 0.23 Cert#5006 10"insulation @ ceiling,30"tube length,single glazed dome,and -Suspended Ceiling dual glazed transition box Solatube 750 DS-C (21 in/530 mm) OphYewv 0.51 1.96 0.22 Cert#5006 10"insulation @ ceiling,30"tube length,single glazed dome,and Suspended Ceilinc dual glazed transition box Solatube 750 DS-C (21 in/530 mm) Prismatic@ 0.51 1.96 0.21 Cert.#5006 10"insulation @ ceiling,30"tube length,dual glazed dome,and Suspended Ceiling dual glazed transition box w th Inner Dome Solatube 750 DS-C (21 in/530 mm) OptiView® 0.51 1.96 0.19 Cert#5006 10"insulation @ ceiling,30"tube length,dual glazed dome,and Suspended Ceiling dual glazed transition box with Inner Dome Part Number:900195 v1.0 @Copyright 2013 Solatube International,Inc. All rights reserved. SOLATUBE INT.,ERNAT"NAkiiiGHT IMPACT 160 DS (10") & 290 D (14") TUBULAR DEN INSTALLATION ANCHORAGE DETAILS GENERAL NOTES: INSTALLATION NOTES: 1. THE PRODUCT ANCHORAGE SHOWN HEREIN IS DESIGNED TO COMPLY WITH THE CURRENT EDITION 1.ONE(1)INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION SHOWN ON SHEETS 2 AND 3. OF THE FLORIDA BUILDING CODE(FBC)REQUIREMENTS,INCLUDING HIGH VELOCITY HURRICANE ZONE(HVHZ)AT THE DESIGN PRESSURES STATED HEREIN. 2.THE NUMBER OF INSTALLATION ANCHORS DEPICTED IS THE MINIMUM NUMBER OF ANCHORS TO BE USED FOR PROC 2. THE PRODUCT DETAILS CONTAINED HEREIN ARE BASED UPON SIGNED AND SEALED TEST REPORT INSTALLATION,ALL UNITS REQUIRE EIGHT(8)ANCHORS MINIMUM LOCATED AT ALL CORNERS.ANCHOR ENGINEERINI ATI85320.01-301-18 AND ASSOCIATED LABORATORY STAMPED DRAWINGS. ENGAGEMENT INTO ROOF SHEATHING AND NOT 2X ROOF FRAMING. 2.1. INSTALLATION SHALL BE INTO 7/16"MINIMUM THICKNESS ROOF SHEATHING(SEE NOTES BELOW), 3. THE PRODUCT HAS BEEN TESTED TO TAS 201,TAS 202 AND TAS203(ATI TEST REPORT ATI 2.2. IF TDD INSTALLATION LOCATION REQUIRES ANCHORS TO ENGAGE INTO 2X FRAMING,THAT IS ACCEPTABLE. 8532D.01-301-18)AND FOUND TO BE IN CONFORMANCE WITH THE CURRENT EDITION OF THE FLORIDA 3.ANCHOR REQUIREMENTS; BUILDING CODE(FBC)INCLUDING HIGH VELOCITY HURRICANE ZONE.THE DESIGN PRESSURES 3.1. FOR INSTALLATION INTO 7/18"MINIMUM THICKNESS ROOF SHEATHING(SEE NOTE 6 BELOW),USE A#10 TYPEAB SHOWN IN DESIGN PRESSURE RATING TABLE ON SHEET 1 OF THIS DRAWING ARE BASED ON THE ROUND HEAD OR TRUSS HEAD TAPPING SCREWS MEETING ASME/ANSI 618.6.4 OF SUFFICIENT LENGTH TO ENSL RESULTS OF TEST REPORT NO,ATI 86320.01-301-18 DIVIDED BY A FACTOR OF SAFETY OF 2 WHERE APPLICABLE. PROTRUDING SCREW THREADS AT LEAST 112'BEYOND THE INTERIOR SURFACE OF ROOF SHEATHING.EDGE DI CENTERLINE OF SCREW TO EDGE OF SHEATHING SHALL BE AT LEAST 314 INCH. 3.2. FOR INSTALLATION THROUGH ROOF SHEATHING INTO 2X WOOD ROOF FRAMING(SEE NOTE 6 BELOW),USE A#1 4. PLASTIC COMPONENTS OF THE SOLATUBE TUBULAR DAYLIGHT DEVICE HAVE BEEN EVALUATED TO THE REQUIREMENTS OF THE CURRENT EDITION OF THE FLORIDA BUILDING CODE INCLUDING THE HEAD, .1ABROUND HEAD E TRUSS HEAD TAPPING SCREWS MEETING ABME/ANSI B1 EA HI THE SAME LENGTH SAS T HIGH VELOCITY ZONE AND ARE IN COMPLIANCE AS DOCUMENTED IN PRODUCT EVALUATION REPORT NOTE 9.1 ABOVE.EDGE DISTANCE FROM CENTERLINE OF SCREW TO EDGE OF SHEATHING SHALL BEAT LEAST NO.1971,BY ROBERT J.AMORUSO,P.E. 4.MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE ROOF FINISHES. 5. ADEQUACY OF THE EXISTING STRUCTURAL ROOF SHEATHING AND SUPPORTING 2X FRAMING AS A 5.INSTALLATION ANCHORS MUST BE MADE OF CORROSION RESISTANT MATERIAL OR HAVE A CORROSION RESISTANT MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF 6. INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE BASED ON SUBSTRATE MATERIALS WITH THE FOL RECORD FOR THE PROJECT OF INSTALLATION. PROPERTIES.ROOF SHEATHING THICKNESS,GROUP OR GRADE MAY BE MANDATED BY JURISDICATION REQUIREME 6. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ACTUAL THEREFORE THICKNESS AND GROUP/GRADE SHOWN BELOW WILL BE CONSIDERED MINIMUM. CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM 6.1. 7/16"THICK PLYWOOD-SPECIES GROUP 1 T 2(APA VOLUNTARY PRODUCT STANDARD PSI)MINIMUM. THE REQUIREMENTS DETAILED HEREIN,A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE 6,2. 7/18"OSB-SHEATHING GRADE (APA VOLUNTARY PRODUCT STANDARD PS 2)MINIMUM. SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT. 7.INS TALLATIOWMOUNTING CONDITIONS AND LIMITATIONS OF USE AS REQUIRED BY THE FOLLOWING SECTIONS OF TF 7. THIS PRODUCT EVALUATION DOCUMENT ADDRESSES THE STRUCTURAL ATTACHMENT OF THE EDITION OF THE FLORIDA BUILDING CODE(FBC)AND FLORIDA RESIDENTIAL CODE(FRC)SHALL BE MET. SKYLIGHTITUBULAR DAYLIGHT DEVICE TO THE ROOF SHEATHING ONLY.PREPARATION OF THE ROOF 7.1. FBC CHAPTER 24,SLOPED GLAZING AND SKYLIGHTS SHEATHING AND ROOF COVERING(S)TO RECEIVE THE SKYLIGHTITUBULAR DAYLIGHT DEVICE SHALL BE 7.2. FRC CHAPTER 26,LIGHT TRANSMITTING PLASTIC SKYLIGHT GLAZING PER THE MANUFACTURER'S INSTRUCTIONS AND COMPLIANT WITH CHAPTER 15 OF THE CURRENT 7.3. FRC CHAPTER 3,SKYLIGHTS AND SLOPED GLAZING EDITION OF THE FLORIDA BUILDING CODE AND CHAPTER 9 OF THE CURRENT EDITION OF THE FLORIDA RESIDENTIAL CODE. B.A CURB CONSTRUCTED IN ACCORDANCE WITH THE REQUIREMENTS FOR THE TYPE OF CONSTRUCTION CLASSIFICAI LEAST 4 INCHES ABOVE THE PLANE OF THE ROOF BY OTHERS IS ALLOWED.ADDITIONAL INSTALLATION DETAILING A 8. IN ACCORDANCE WITH THE CURRENT EDITION FBC DISSIMILAR METALS INCLUDING FASTENERS THAT ENGINEERED INSTALLATION EVALUATION BY A LICENSED DESIGN PROFESSIONAL WILL BE REQUIRED FOR SUBMITT, MAY COME INTO CONTACT WITH ALUMINUM SKYLIGHT FRAMING SHALL HAVE BEEN PROTECTED. TO THIS PRODUCT EVALUATION DOCUMENT. TABLE OF CONTENTS SHEET DESCRIPTION 1 GENERAL AND INSTALLATION NOTES 2 ELEVATIONS, ANCHORING, SECTIONS, DETAILS AND B.O.M. 3 290 DS (14) FLASHING OPTIONS 4 160 DS (10) FLASHING OPTIONS 5 INSTALLATION DETAILS AND SECTIONS 6 OPTIONAL DIFFUSER DETAILS DESIGN PRESSURE RATING(PSF) IMPACT RATING UNIT WHERE WATER INFILTRATION I WHERE WATER INFILTRATION TEST IS REQUIRED TEST IS NO7 REQUIRED LARGE MISSLE 16 15 14 21 NOTES: � _ (4 SMS 25 24 Q STRUCTURAL ELEMENTS[►LYWOOD,RAF FASTENERS BY OTHERS R SHOWN FOR REFERENCE!23 2. ALL TUBE JOINTS i SEAMS TAPED WITH 2" J1 ��7 JJ B SEEPAGE 6 FOR ALTERNATE DIFFUSER CO QREM#22;RECTANGULAR FOAM OR SEAL ' FLASHING SHOWN WITH OPTIONAL. 2"-48"TALL TURRET EXTENSION A C 18.0 17 18 20 19 22 0 10 4 DETAIL B 13.6 TUBE' -' 2.O LAP 1 11 2 21 12 26 LAP 41.1 28 3 18 27 7 4 1 6 5 SECTION A-A REM N0. Ott. PARTNG DESCRPM14 MAiQiIAL 1 1 41 DOME 29008 p 8 2 1 41 LIGHTAACKER Ra.ECIOR 250_DS ___._ _ ALUMNUM LAMINATE'• 3 1 41am__ DOME RING 290 D8 PN1A 4 1 IO FOAMSEAL RECTANGULAR I/SX871'Q' FOAM LVARIDUS - 5 4 700240 SCR 1 SMS Sim 6 4 410730 DOME RM SPACER POLY DE 7 3 410750 TOP TLW CLIP PMMA B 1 ARIES' FLASHING 87EEL 8 1 7MM70MM SEALANT URETHANE I 10 80X2 6M8 8 11 1 3=40TOPm DS ALUMINA 2 7 1 30IBON.101d10 E721USE 1424'29008 LAMM '^ 13 7 1 302120 BOTTOM TUBE 290 UJJO:LIM 1A11NA1E _74 4 10P20 O.AMP _ P_OLYALIM • / 75 4 7OD400 SCREW 0011.§'SMS 81!$ 13 1 410415 CE]UND NNS 200 08 PM UA 17 i421345 .290 D8 NATURAL EFFECT LENS PET . 10 1 410, 420,080 290 DS DIFFUSEiT PANEL PC iB 1 410520 86 RN02W W PMMA 9 10 20 1 �o DS DIFFUSER SEAL EM FOAid DETAIL C - 21 1 U M45 DBEAL HOLLOW FOAM 22 1 6001.ZD FOAM SELL REC7ANGI1L8EWtP CLOSED CELL FOAM ' ALTENW11E(PROVIDED BY USER) ACRYLICBEALANfLVAAiWb; ITEM —__ ___.__ _—_ ___ NO. OTY. PARTNO. DESCRPTION 1V17FAIAL ^I 23 2 1 420280 290 DS MUATKM PANEL JOTSHOWN) PN►Vl - '� " 24 4 {20270 INSULATION PANEL CUPNOT SHOWN PMMA . 25 11 VARIES'- 1MTRETEXIE/L11ON 8 28 410010 180 D9 DOME SHOCK TUNER P 27 1 1 570002129006 DAYLIGHT dA R 290 DS (1411) FLASHING OPTIONS Qf15.9 TOP OF FLASHING 015.9 23.3 b.1 TOP OF FLASHING —" — — 8 7 6.1 18.0 .` 9.2 .: 6.0 18.0 23.3 8.7 PITCHED FLAT 6' 8X FLASHING FASTENERS FLASHING FASTENER SPAC FLAT 4',FLAT d"&PITCHI TOP OF 015.9 FLASHING 015.9 TOP OF FLASHING 8X FLASHING FASTENERS, 6.1 2X FASTENERS PER SIDE 6.2 - - :. 2.0 4.0 18.0 1 1 4.0 FLAT 4" CURB 160-DS (10") FLASHING OPTIONS -011.9 /-MP TOP OF FLASHING TOP OF FLASHING 5.0 5.0 6.0 7.4 16'6 _ 8X FLASHING FA 20.0 8.1 FLAT 6" PITCHED O G 20.0 8.1 O c Q Q • FLASHING FASTENER SPACIN< FLAT 4",FLAT 6"&PITCHED 011.9 TOP OF FLASHING 011.9 TOP OF FLASHING E. i 4.0 2.0 4.0 • 14.8 16.6 8X FLASHING FASTENERS, FLAT 4" 2X FASTENERS PER SIDE CURB FLASHING -a-2TTYP. .0 20". ROOF COVERING BY OTHERS INSTALLATION SCREW (8 TOTAL) ROOF SHEATHING SEALANT 2(r 27 TYP. 7"TYK 1/2,MIN. 0 FLASHING OF SHEATHING EMBEDMENT ------- ------ - 'TIER DROP' DECORATIVE 'OPTIVEW' DECORATIVE 160 DS10" AND 290 DS 11 FIXTURE ASSEMBLY FIXTURE ASSEMBLY ( ) DECORATIVE FIXTURE OPTIO MOM 'JUST FROST' DECORATIVE FIXTURE ASSEMBLY 3 2 1 4 1 3 2 flER DROP WIR ER ASEFAIBLY COitPAtmdTS' ....—OPIA�ONFUSFR ASSEMUY COlPOMM —�.• REIN MQ 4,Y. DESCRfP1lDM I ERM G. 1 1 OIASS TRU RM TE1049a D f CLASS REL NO. MY. DESCRInW ,,..LITETNAt LHdS TELPET✓FD tiU�1S MAW . 1 GMSS TRIP RRRi=— TFLFQEFO am 2 1 OPFLISER PANEL OPRM}EW PC 3 1 fAA13"TROT R1tffi TELPEIfFD GIASS S f.ETl9 FASTENER SDIIMFSS SIEFl, A J 1 LEMS FASIE)" STA1lEE53 STEEL 'QUADRA FROST' DECORATIVE 'AURORA GLO' DECORATIVE 1 2 FIXTURE ASSEMBLY FIXTURE ASSEMBLY d1Sr RiOSf SWRI SER ASSFALY COIIPOREMIS REL EID. cT+: RESwPR0.'I I Luaw am IEM IlEkown d 2 3 ILEms FASTENER svmLESS S 290 DS (14") DECORATIVE FIXTURE OPTIONS 2 AURORA CLO BIFPU5ER ABLY COUPOME= 'r REM NO. .-4TTYQ,„AS_S __ NOOTY: DTRESL'CWRPNYRWNS�P�UNW OTIEARSNSL JUST FRWOfFFLM USERSPhGIASS LENS &A 2 4 111EW OESCRFTIO! 7EI/'EM 044LS , Business & Professional Regulation BCIS Home I Login 1 User Registratian Hot Topic I Submit Surcharge Stats 0 Facts Publications I FBC Staff I SCIS Site Map j Links j Search Florida 1 a Produet ApprovalUSER:Public User Product Approval Menu>Product or Aoollcation Search>Application List>Application Detail •,i 11 FL# FL2847-119 Application Type Affirmation Code Version 2017 Application Status Approved Comments Archived El Product Manufacturer Lomanco,Inc Address/Phone/Email 2101 West Main Street Jacksonville,AR 72076 (501)982-6511 acarter@lomanco.com Authorized Signature Andrew Carter acarter@lomanco.com Technical Representative Andrew Carter Address/Phone/Email 2101 West Main Street Jacksonville,AR 72076 (501)982-6511 Ext 361 .acarter@lomanco.com Quality Assurance Representative Andrew Carter. Address/Phone/Emall 2101 West Main Street Jacksonville,AR 72078 (501)982-6511 Ext 361 acarter@lomanco.com Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Product Evaluation Entity Evaluation Entity Miami-Dade BCCO-EVIL Quality Assurance Entity Miami-Dade BCCO-QUA Quality Assurance Contract Expiration Date 09/04/2018 Validated By Miami-Dade BCCO-VAL I Certificate of.Independence Referenced Standard and Year(of Standard) Standard Year Miami-Dade TAS 100(A) 1995 Equivalence of Product Standards Certified By Sections from the Code ©I affirm that there are no changes In the new Florida Building Code which affect my product(s)and my product(s)are in compliance with the new Florida Building Code. -K tl Documentation from approved Evaluation or Validation Entity OYes ONO ON/A Product Approval Method Method 1 Option C Date Submitted 11/08/2017 Date Validated 11/08/2017 Date Pending FBC Approval Date Approved 11/12/2017 Summary of Products FL# Model,Number or Name Description 2847.1 Lo-OmniRidge LOR9-4 Gun Nallable 4'Ridge Vent for 9"Cap Shingles Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL2847 R9 II LOR9-4 13070110 odf Approved for use outside HVHZ:Yes Verified By: Mlami-Dade BCCO-EVIL Impact Resistant:N/A Created by Independent Third Party: Design Pressure:N/A Evaluation Reports Other:1.Refer to applicable building codes for required FL2847 R9 AE LOR9-4 13070110.12df ventilation.2.Omni Roll Ridge Vent shall not be installed on roof hips.3.Omni ROTI Ridge Vent shall not be connected at ridge Intersection,nor within 12"of any side wall or roof protrusion,with a ventilation slot clearance of 12"from such obstructions.4.Omni Roll Ridge Vent shall not be installed on roof mean heights greater than 33 feet. 2847.2 Lo-OmniRoll LOR-30 30'Gun Nallable Shingle Over Ridge Vent Limits of Use Installation Instructions. Approved for use in HVHZ:Yes FL2847 R9 Ii LOR-30 13070111 p_df Approved for use outside HVHZ:Yes Verified By: Miami-Dade BCCO-EVIL Impact Resistant:N/A Created by Independent Third Party: Design Pressure:N/A Evaluation Reports Other:1.Refer to applicable building codes for required FL2847 R9 AE LOR-30 13070111 odf ventilation.2.OmniRidge Vent shall not be installed on roof mean heights greater than 33 feet. 2847.3 OmnlRidge OR-4 4'Shingle Over Ridge Vent Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL2847 R9 II Lomanco OR-4-NOA 16051027.pd Approved for use outside HVHZ:Yes Verified By: Miami-Dade BCCO-EVL Impact Resistant:N/A Created by Independent Third Party: Design Pressure:N/A Evaluation Reports Other:1.Refer to applicable building codes for required FI 7847 R9 AE Lomanco OR-4-NOA 16051027.udf ventilation.2.OmniRidge Vent shall not be installed on roof mean heights greater than 33 feet. Back Next Contact Us::7601 Blair Stone Road Tallahassee FL 32399 Phone:B50-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ®® Credit Card Safe PLOP=D"PAqw""TOp Businessi Professional BCIs Hpme � Log In User Registration Hot Tapia Submit Surcharge Stats&Facts _Publications FBC Staff BCS Site Map_; Links { search i Rorida - Produ i4 Approval .,.F� USER:-Public User . Product Approval Menu>Product or Anolintlon Search>Application List>Applicatlen Detail , • FL# FL2569-R13 Application Type . Revision ..Code Veisiori : 2017. Application Status Approved COrriment5 .. - Archived Product Manufacturer Soprema,Inc. (Canada) Address/Phone/Email 1640 rue Haggarty Drummondville,NON-US 00000 (819)478-2400 memathieu@soprema.ca Authorized Signature Marc-Etienne Mathieu memathleu @soprema.ca Technical Representative Marc-Etienne Mathieu Address/Phone/Email 1688 Jean-Berchmans-Michaud Drummondville,NON-US 00000 (819)478-2400 Ext 3327 memathleu @soprema.ca Quality Assurance Representative Jean-Francois Cote,Ph.D. Address/Phone/Email 1640 rue Haggarty Drummondville (888)-811-3145 )fcote@soprema.ca Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert I.M.Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 07/18/2020 Validated By John W.Knezevich,PE L7 Validation Checklist-Hardcopy Received Certificate of Independence FL 69 R13 COI 2017 01 COI Nieminen odf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2015 ASTM D6163 2008 FM 4474 2011 FRSA/TRI April 2012(04-12) 2012 TAS 110 2000 UL 1897 2012 r Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/09/2017 Date Validated 10/11/2017 Date Pending FBC Approval 10/15/2017 Date Approved 12/12/2017 Summarv,of Products FL# Model,Number or Description Name 2569.1 Soprema Roof Self adhering roof underlayments Underlayments Limits of Use Installation Instructions Approved for use in HVHZ:No FI 2569 R13 II 2017 10 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569- Approved for use outside HVHZ:Yes R13.odf Impact Resistant:N/A Verified By, Robert Nieminen,P.E.PE-59166 Design Pressure:+N/A/-150 Created by Independent Third Party;Yes Other:1.)Refer to ER Section 5 for Evaluation Reports Limits of Use.2.)The design pressure FL2569 R13 AE 2017 10 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569- noted herein pertains to underlayment R13.Ddf systems used beneath adhesive-set tile Created by Independent Third Party;Yes systems.Refer to ER Section 5.6.4 for details. Back Ne Contact Us;;2601 Blair Stone Road.Tallahassee FL 32399 Phage:650-487- The State of Florida Is an AA/EEO employer.Cowriaht 2007-2013 State of Florida,::Privacy Statement;:Accessibility Statement::Refund Statement Under Flodda law,email addresses are public records.If you do not want your e-mail address released In response to a public,records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine it you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: Credit Card Safe r _ EXTERIOR RESEARCH&DESIGN,LLC. Certificate of Authorization#9503 TRINITY� 353 CHRISTIAN STREET,UNIT#13 ERD OXFORD,CT 06478 (203)262-9245 EVALUATION REPORT Soprema,Inc. Evaluation Report S18010.06.09-1111 1640 rue Haggerty FL2569-1113 Drummondville,Quebec J2C 5P8 Canada Date of Issuance:06/15/2009 (819)478-2400 Revision 11:10/06/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Soprema Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT:The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECnON:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: �,y,gnjrnn,,,r tiQ•rye":'�., Robert J.M.Nieminen P.E. %ap''s�.`' c.t-'.,;;: The facsimile seal appearing was authorized by Robert Florida Registration No.59166,Florida DCA ANE1983 '�ics�'�"' �+'k Nieminen,P.E.on 10105/2017.This does not serve as an i �oN�� ,�. electronically signed document CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are,in any way,the Designer of Record for any project on which this Evaluation Report,or.previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY I ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the following sections of the a Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations /Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Resistance FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1507.1.1,71507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 2012 FRSA/TRI April 2012(04-12) Physical Properties ASTM D6163 2008 TAS 110 Accelerated Weathering TAS 110 2000 3. REFERENCES: Enti Examination Reference Date ERD(TST6049) ASTM D1970/TAS 110 2968.05.04-2 05/14/2004 ERD(TST6049) Physical Properties 2757.02.05 02/03/2005 ERD(TST6049) ASTM D1970/TAS 110 2974.03.05-2 05/17/2005 ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005 ERD(TST6049) Wind Resistance 2779.11.05-R1 04/18/2007 ERD(TST6049) TAS 103/TAS 110 S7120.11.07-2 11/02/2007 ERD(TST6049) ASTM D1970/TAS 110 513190.02.09-111 04/01/2010 ERD(TST6049) ASTM D1970/TAS 110 S31370.03.10-1-R1 04/07/2010 ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.10-R1 09/09/2010 ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.09-112 10/05/2010 ERD(TST6049) ASTM D1970 537210.11.11 11/09/2011 ERD(TST6049) ASTM D1970 S40540.02.13-1 02/19/2013 ERD(TST6049) Physical Properties/Tensile Adhesion S43530.02.14-1 02/21/2014 ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/13/2015 ERD(TST6049) Accelerated Weathering SOPC-SC8520.14 04/17/2015 ERD(TST6049) Wind Resistance SOPC-SC14045.05.17-R1 06/07/2017 M-D(CER1592) HVHZ Compliance 15-0508.04 09/24/2015 ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017 PRI(TST5878) Physical Properties SOP-064-02-01 12/03/2013 Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015 UL,LLC(QUA9625) Quality Control Service Confirmation -Exp.07/18/2020 4. PRODUCT DESCRIPTION: 4.1 Lastobond TU HT is a self-adhering, non-woven polyester fabric surfaced, SBS modified bitumen roof underlayment;meets ASTM D1970 and FRSA/TRI April 2012(04-12). 4.2 Lastobond Shield is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths;36 and 45 inch;meets ASTM D1970. 4.3 RESISTO SA SMOOTH PLY 40 is a self-adhering,woven polyethylene surfaced, SBS modified bitumen roof underlayment;available in 3.3 ft x 65 ft rolls;meets ASTM D1970. 4.4 Lastobond Shield HT is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment;meets ASTM D1970. Exterior Research and Design,I.I.C. Evaluation Report S18010.06.09-R11 Certificate o/Authorization#9503 6H EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-R13 Soprema,Inc. Revision 11:10/06/2017 Page 2 of 8 TRINITY(ERD 4.5 Lastobond Pro HT-N is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths;36 and 45 inch;meets ASTM D1970. 4.6 Lastobond Pro HTS is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment;meets ASTM D1970. 4.7 Lastobond 195 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment;meets ASTM D1970. 4.8 Lastobond Eaves Protection Sheet is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment;meets ASTM D1970. 4.9 Lastobond Eco is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment;meets ASTM D1970. 4.10 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced, film-surfaced,SBS modified bitumen roof underlayment;meets ASTM D1970. 4.11 RESISTO L61236 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment,with a 36-inch sheet width;meets ASTM D1970. 4.12 PrimeSource Grip-Rite Eave&Valley Protector is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment,with a 36-inch sheet width;meets ASTM D1970. 4.13 RESISTO LB1244 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment,with a 44-inch sheet width;meets ASTM D1970. 4.14 Colphene FR GR is a self-adhering, fiberglass reinforced, granule-surfaced, SBS modified bitumen roof underlayment;meets ASTM DJ 970 and FRSA/TRI April 2012(04-12). S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed,a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: �. `TABLE 1 +ROOFCOVER OPTIONS : ` Asphalt Nail-On Foam Metal-On Wood Shakes& Slate Underla ment Shingles Tile Tile Shingles Lastobond TU HT Yes Yes Yes Yes Yes Yes See 5.5.1 Lastobond Shield/Pro HT-N/RESISTO SA i s Yes No_ Yes Yes SMOOTH PLY 40 NO ;�.'Np : A a + No Lastobond Shield HT/Pro HT-S Yes Yes Yes Yes, .�,.,,,No , �� Lastobond Eaves Protection Sheet/ Yes No ;, r ..".No No Yes Yes Lastobond 195 >, Lastobond ECO /RESISTO LB1236,Grip- a Rite Eave&Valley Protector/RESISTO YesNo No No Yes Yes f LB1244 Exterior Research and Design,I.I.C. Evaluation Report S18010.06.09-R11 CerWicate of Authorization#9503 6TH EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-R13 Soprema,Inc. Revision 11:10/06/2017 Page 3 of 8 TRINITY ERD 21, -'.:.o!!:.7 7aeual RooF CovER OPnONS Underlayment Asphalt Nail-On Foam-On Metal Wood Shakes& Slate Shingles Tile Tile Shingles +Nil::;.`,; Yes Yes Yes Lastobond Smooth Seal HT Yes ; 'Nd ` r: ,.,: Yes Colphene FR GR Yes. Yes :No'':%%; Yes Yes See 5.5.1 5.5.1 "Foam On Tile"is limited to use of following Approved tele adhesives/underlayment combinations '- ,' TABLE ZR AELOlAfABLE;�ICEADH�SIUE,�:UNDERUkYINEfdTCOMBIN•ATIQN51 ' Adhesive Florida Product Approval Underlayments Dow TileBondTM' FL22525 Lastobond TU HT ICP Adhesives Polyset"AH-160 FL6332 Lastobond TU HT or Colphene FR GR 5.6 Allowable Substrates: 5.6.1 Direct-Bond to Deck: Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,Lastobond TU HT,Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond ECO,RESISTO LB1236,Grip-Rite Eave&Valley Protector,RESISTO LB1244 or Lastobond Smooth Seal HT applied to: ➢ Plywood;ASTM D41 primed plywood;OSB;ASTM D41 primed OSB; Southern Yellow Pine;ASTM D41 primed Southern Yellow Pine;ASTM D41 primed structural concrete. Colphene FR GR applied to: ➢ Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete. Note: ➢ While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours. ➢ Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the self-adhering underlayment. 5.6.2 Bond-to-Insulation: Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,Lastobond TU HT,Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond ECO,RESISTO L61236,Grip-Rite Eave&Valley Protector,RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to: ➢ Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile systems(Lastobond TU HT only),insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474,Appendix D,Testing Application Standard TAS 114,Appendix J or UL1807. 1 Refer to Tile Manufacturer's orAdhesive Manufacturers Florida Product Approval for Overturning Moment Resistance Performance. Exterior Research and Design,LLC. Evaluation Report S18010.06.09-1111 awof cateofAuthoriza8on#9503 6TH EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-1133 Soprema,Inc. Revision 11:10/06/2017 Page 4 of 8 ��TRINIWIERD 5.6.3 Bond to Mechanically Attached Base Laver:. Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236,Grip-Rite Eave&Valley Protector,RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to: ➢ ASTM D226,Type I or II felt;Sopra-G;Modified Sopra-G. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam-on tile systems (Lastobond TU HT only), base layer shall be attached in accordance with FRSA/TRI April 2012(04-12). 5.6.4 Wind Resistance for Underlayment Systems in Foam-0n Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and.reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04-12)or FBC 1609 for determination of design wind pressures. #1 Maximum Design Pressure=-45.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)Elastocol Stick,Elastocol 600c or RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered. #2 Maximum Design Pressure=-67.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Elastocol 600c Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered. #3 Maximum Design Pressure=-150.0 psf: Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to satisfaction of Authority Having Jurisdiction. Deck Preparation:Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood projections shall be removed/sanded. Primer: (Optional)RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT, self-adhered, shall be thoroughly roll using hand roller and/or weighted roller to ensure there are no voids, and ensure there are no voids/bridging at side and end-laps. #4 Maximum Design Pressure=-60.0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517:5.1) and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three (3), equally spaced rows in the center of the sheet. Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered 5.6.4.1 All other direct-deck, adhered Soprema underlayment systems beneath foam-on tile systems carry a Maximum Design Pressure of-45 psf. Exterior Research and Design,LLC. Evaluation Report 518010.06.09-1111 CeitykateofAuthorization#9503 6TM EDITION(2017)FBC NON-HVHZEVAWATION FL2569-1113 Soprema,Inc. Revision 11:10/06/2017 Page 5 of 8 f TRINITY�ERD 5.6.4.2 For mechanically attached Base Sheet,the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. 5.7 Exposure Limitations: Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO LB1236,Grip-Rite Eave&Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30- days after installation. Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT or Lastobond Pro HT-S shall not be left exposed for longer than 90-days after installation. Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than 180-days after installation. 5.8 Tile Slippage Limitations(TAS 103 per FRSA/TRI April 2012(04-12)): When loading roof tiles on the underlayment in direct-deck tile assemblies,the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 2 TILE SLIPPAGE LIMI7A71bN5 FOR DIRECT DEEK'TIL�'INSTALLATIONS :;:;• Underlayment Tile Profile Staging Method Maximum Slope Flat Max.10-tile stack 6:12 Lugged Max.10-tile stack 5:12 Max.10-tile stack(bottom 2-tile stack shall be inverted,followed by 8 tiles high 6:12 on slope,as shown below) Lastobond TU HT Lugged Colphene FR GR Flat Max.10-tile stack 5:12 Lugged Max.10-tile stack 6:12 Exterior Research and Design,LLC. Evaluation Report S18010.06.09-Rii Certificate ofAuthorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FLZS69-R13 Soprema,Inc. Revision 11:10/06/2017 Page 6 of 8 F)(D TRINITY)ERD 6. INSTALLATION: 6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER(if applicable). 6 3 Lastobond Tl!HT,La�stobond Sh1e1d,�Lastobond Pro NT N,RESISTO SA SMOO'C'H PLY:�FO,Lastobond Shleld. FI,T,Lastoborid Pro.HTS, LastobondEaves Rro�ection-Sheers�2lstobond 195,Lastobond Eco,Lastohond •, Smooth Sea[_HT,RESISTO LB1236;Grlp Rlte Ease J�iVal ley Protector,RESISTO LB`1244 or Colphene FR 6R 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be Installed. 6.3.2 Non-Tile Applications: While priming is optional, Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge., Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the substrate and unroll the remaining membrane as far-as possible. Once the entire length of membrane is in place, peel-off the release film diagonally while holding the membrane tight. Firmly roll the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6- inches and staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps shall be sealed using either heat-welding or hot air welding techniques. When installing at slopes above 8:12,Soprema recommends back-nailing in the overlap area at the top of the sheet at 12-inch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths.Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place,working from the center of the valley or ridge in each direction. For valleys,apply the sheet starting at the lowest point and work upward. 6.3.3 Tile Applications(Lastobond TU HT or Colphene FR GR only): Reference is made to FRSA/TRI April 2012 (0412) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For foam-on tile applications,reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012(04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See Table 2 herein,and Soprema published requirements for tile staging. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. Exterior Research and Design,I.I.C. Evaluation Report S18010.06.09-R11 CertiAcateofAuthorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL2S69-R13 Soprema,Inc. Revision 11:10/06/2017 Page 7 of 8 �TRINFYIERD 8. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements. The following plants have qualified products under their respective physical properties specifications. Plant; v Lastobond Shield,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT, Drummondville, Lastobond Pro HT-N,Lastobond Pro HT-S,Lastobond 195,Lastobond QC(Canada) ASTM D1970 Eaves Protection Sheet,Lastobond Eco,Lastobond Smooth Seal HT, RESISTO[B1236,PrimeSource Grip-Rite Eave&Valley Protector, RESISTO LB1244 ASTM D1970&FRSA/TRl 04-12 Colphene FR GR Wadsworth,OH Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Eco, ASTM D1970 Lastobond Smooth Seal HT,RESISTO LB1236,PrimeSource Grip-Rite Eave&Valley Protector,RESISTO LB1244 ASTM D1970&FRSA/TRI 04-12 Lastobond TU HT;Colphene FR GR Gulfport,MS Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Eco, ASTM D1970 Lastobond Smooth Seal HT,RESISTO LB1236,PrimeSource Grip-Rite I Eave&Valley Protector,RESISTO LB1244 9. QUALITY ASSURANCE ENTITY: UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com END OF EVALUATION REPORT- Exterior Research and Design,LLC Evaluation Report S18010.06.09-ItIl Certificate ofAuthorization 19303 6T"EDITION(2017)FBC NON-HVHZ EVAWATION F1.2569-1113 Soprema,Inc. Revision 11:10/06/2017 Page 8 of 8 r FLORIDA DOPAPTIASINIT OF Business & Professional Regulation BCIS.Home I Log In User Registration Hot Topic Submit Surcharge Stats fl Facts Publications FBC Statf BCIS Site Map Links Search i Fl ritla i Product Approval' USER:Public User PmductAoomv i Menu i.Pt-duct or_Aogyeation'Search>'APPilraf100 Llsf>Appilcatien Qetail FL# FL7006-R30 Application Type Revision Code V.ersioii 2017 Application Status... ApprCved *Approved by DBPR:Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Arclilved ❑ Product Manufacturer IKO Industries,Ltd Address/Phone/Email 40 Hansen Road South Brampton,NON-US L6W 3H4 (708)496-2800 Ext 200 rmetzOO1@tampabay.rr.com Authorized Signature Robert Metz rmetzOO1@tampabay.rr.com Technical Representative Bob Metz Address/Phone/Email REMCO of Pinellas 456 Avila Circle NE Saint Petersburg,FL 33703 (727)776-5261 rmetzDO1@tampabay.rr.com Quality Assurance Representative Don Shaw Address/Phone/Emall IKO Industries LTD 120 Hay Rd. Wilmington,DE 19808 (717)579-6706 don.shaw@iko.com Category Roofing Subcategory Asphalt Shingles Compliance Method Certification Mark or Listing Certification Agency FM Approvals-CER Validated By Locke Bowden O Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Standard Year ASTM D3161 modified to 110 mph 2016 ASTM D3462 2010 ASTM D7158 Class H 2011 ASTM ESOB 2011 - Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 10/08/2017 Date Validated 10/30/2017 Date Pending FBC Approval Date Approved 11/01/2017 Summary of Products FL# Model,Number or Name Description 7006.1 Cambridge,Cambridge HD, Laminated architectural fiberglass asphalt shingle Biltmore and Biltmore HD manufactured at IKO's Kankakee,IL; Hawkesbury,Ont.; Wilmington,DE;Sylacauga,AL and Toronto,Ont.plants Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL7006 R10 C CAC Letter-ASTM D3161 letter-(9-26- Approved for use outside HVHZ:Yes 20171 from FM.Ddf Impact Resistant:N/A FL7006 RIO C CAC Letter-ASTM D3462 letter-(9-26- Design Pressure.N/A 20171.Odf Other: FL7006 R10 C CAC Letter-ASTM E108 letter-(9-26- 20171.odf Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions FL7006 RIO II IKO-187-02-01 Letter-Installation Instructions for FBC FL7006.pdf Verified By: Duc T Nguyen 65034 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 7006.2 Hip and Ridge 12 Cap This Is a 12"x 12"fiberglass asphalt shingle used to cover the hip and/or ridge of an asphalt shingle roof system manufactured at IKO's Kankakee,IL,Toronto,Ont.and Brampton,Ontario plants. Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL7006 RSO C CAC ASTM D 3462-Shingle letter Approved for use outside HVHZ:Yes Surveillance Audit Location-(6-28-2017).pdf Impact Resistant:N/A FL7006 RSO C CAC Letter-ASTM D3161 letter-(9-26- Design Pressure:N/A 2017)from FM.odf Other: FL7006 RSO C CAC Letter-ASTM D3462 letter-(9-26- 2017),od FL7006 RIO C CAC Letter-ASTM E108 letter-(9-26- 21 df Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions FL7006 RSO lI Hip and Ridge Cao Shingle Installation Instructions.odf FL7006 RSO II IKO-187-02-01 Letter-Installation Instructions for FBC FL7006.gdf Verified By:Duc T Nguyen PE 65034 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 7006.3 Leading Edge Plus Asphalt Shingle One piece fiberglass asphalt shingle used as a starter strip at Starter Strip the bottom of a roof system manufactured in Brampton and Hawkesbury,Ontario plants Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL7006 RSO C CAC Letter-ASTM D3161 letter-(9-26- Approved for use outside HVHZ:Yes 2017)from FM.Odf Impact Resistant:N/A FL7006 RIO C GAG Letter-ASTM D3462 letter-(9-26- Design Pressure:N/A 20171.odf Other: FL7006 RIO C CAC Letter-ASTM EI08 letter-(9-26- 2017). df Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions FL7006 RIO II IKO-187-02-01 Letter-Installation Instructions for FBC FL7006.ydf FL7006 RSO II Roofing-Products-Leading-Edge-Plus- Aoolicatlon-EN(1l.ndf Verlfted By: Duc T Nguyen PE 65034 Created by Independent Third Party:No Evaluation Reports Created by Independent Third Party: 7006.4 Marathon Plus AR,Superglass Plus 3 tab fiberglass asphalt shingle manufactured at IKO's AR Brampton,Ontario,Hawkesbury Ont.,Toronto,Ont.; Sylacauga,AL and Kanakakee,IL plants Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL7006 RIO C CAC Letter-ASTM D3161 letter-(9-26- Approved for use outside HVHZ:Yes 2017)from FM.Ddf Impact Resistant:N/A FL7006 R10 C CAC Letter-ASTM D3462 letter-(9-26- Design Pressure:N/A 2017).Ddf Other: FL7006 R10 C CAC Letter-ASTM E108 letter-(9-26- 2017).odf Quality Assurance Contract Expiration Date 12/20/2020 Installation Instructions FL7006 R10 II IKO-187-02-01 Letter-Installation Instructions for FBC FL7006.pdf Verified By: Duc T Nguyen 65034 Created by Independent Third Party:No Evaluation Reports Created by Independent Third Party: Back Next Contact Us:;2601 Blair Stone Road,Tallahassee FL 32399 Phone:8S0-4a7-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement:;Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275 (1),Florida statutes,effective October 1,2012,licensees licensed under Chapter 45S,F.S.must provide the Department with an email address If they have one.The emalis provided may be used for pfficlai communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public To determine If you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: Credit Card Safe AM CONSTRUCTION MATERIALS TECHNOLOGIES October 27,2017 IKO Industries, Ltd 120 Hay Rd. Wilmington, DE 19809 Re: FBC FL7006 Sir(s), PRI Construction Materials Technologies has completed a technical review and attached sealed shingle instructions in compliance the 2017 Florida Building Code. This review was completed based on the receipt of following evidence from IKO Industries, Ltd: 1) IKO Shingle Application Instructions—3-Tab Shingles (EN-3Tab Appins_8AGXEFS-2012-11 reformatted 2013-02-rev07/13-Florida) 2) IKO Laminated Shingles Application Instructions (EN-Laminated Appins 8TTEFS-2012-04—reformatted 2013-02-rev07/13-Florida) 3) IKO Hip and Ridge 12 Application Instructions (EN-HipandRidge12_3HRTri-2013-08_reformatted 2013-08) 4) IKO Leading Edge Plus Shingle Application Instructions (EN-3LEP-Tri-2012-06—reformatted 2013-03) 5) ASTM D3161 Test Report(FM Approvals Project No. 3040947) The attached instructions should be used in conjunction with the published manufacturer's application instructions and applicable code. In the event the instructions conflict,these instructions shall govem. Statement of Independence:PRI Construction Materials Technologies and/or Duc T.Nguyen,FL P.E.do not have nor plan to acquire a financial interest in any company manufacturing or distributing products for which the test reports are issued. Signed: C Signed: Brad Grzytbo ski Duc T. u en Managing rector Florida R Bred Professional Engineer P.E.Number:65034 Date: October 27,2017 Date: October 27,2017 Attachments: A)IKO Shingle Application Instructions-3-Tab B) IKO Laminated Shingles Application Instructions C)IKO Hip and Ridge 12 Application Instructions D)IKO Leading Edge Plus Application Instructions IKO-187-02-01 FRI Constriction Materials Technologies,LLC.6412 Badger Drive Tampa,R 33610 Tel:813-621-5777 Fax:813-621-5840 a-mail.•materialstesting@pdcmtcom WebSite:http:/Mwvw.pdcmtcom IKO Installation Instructions for Asphalt Shingles Page 2 of 5 IKO Shingle Application Instructions — 3-Tab Shingles (ASTM D3161, Class F—1KO Marathon 25 AR and CRC Superglass M25AR) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT,THESE INSTRUCTIONS WILL GOVERN. ROOF DECK: Solidly sheathed and fastened deck conforming to 2017 FBC. UNDERLAYMENT:Applied in accordance with building code requirements.For areas where the roof slope is less than 4" per foot down to 2" per foot, use 2 layers of underlayment conforming to building code requirements,the first sheet overlapping the eave protection by 19",followed by full 36"widths overlapping each preceding course by 19"or other Approved underlayments in accordance with the qualified application instructions. For areas where the roof slope is 4" per foot or greater, cover the deck with one ply of underlayment laid parallel to the eaves,with 2"horizontal laps and 4"end laps. Apply metal drip edges on top of any underlay along rake edges and directly to the deck along eaves in accordance with building code requirements. NAILING:Use galvanized(zinc coated)roofing nails, 11 or 12 gauge,with at least 3/8"diameter heads,long enough to penetrate through plywood or 3/4"into boards. Use 4 nails per shingle placed 6-1/8"above the butt edge,approx. 1"and 13"from each end and 1/2"above each cutout. Drive nails straight so that nail head is flush with, but not cutting into shingle surface. NAILING ON STEEP SLOPES:For steep slopes of 21"per foot(60°)or more,use 6 nails per shingle placed as shown below. Ensure that no nail is within 2"of a joint/cutout of the underlying shingle. Seal down each shingle at time of application with three 1"diameter(approx.size and thickness of a quarter)spots of asphalt plastic cement placed under the shingle 2"above the bottom edge and equally spaced along the shingle. Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the heat of direct sunlight. EXPOSURE: Installed shingles shall have a maximum average exposure of 5-5/8". STEEP SLOPES 14rr 1-1R" +—i=--i~SEALING STRIP ——• f �;�, � 1 NAILS NAILS DO NOT NAIL INTO OR ABOVE THE SEALING STRIP PRI Construction Materials Technologies,LLC.6412 Badger Drive Tampa,FL 33610 Tel:813.621-5777 Fax:813.6215040 e-mail:m&dalstesbng@pdcmtcom Web$fte:htIPJ/www.pricmtcom IKO Installation Instructions for Asphalt Shingles Page 3 of 5 IKO Laminated Shingles Application Instructions (ASTM D3161, Class F—Cambridge, Cambridge HD, and CRC Biltmore AR) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT,THESE INSTRUCTIONS WILL GOVERN. ROOF DECK: Solidly sheathed and fastened deck conforming to 2017 FBC. UNDERLAYMENT:Applied in accordance with building code requirements.For areas where the roof slope is less than 4" per foot down to 2" per foot, use 2 layers of underlayment conforming to building code requirements,the first sheet overlapping the eave protection by 19",followed by full 36"widths overlapping each preceding course by 19"or other Approved underlayments in accordance with the qualified application instructions. For areas where the roof slope is 4" per foot or greater, cover the deck with one ply of underlayment laid parallel to the eaves,with 2"horizontal laps and 4"end laps. Apply metal drip edges on top of any underlay along rake edges and directly to the deck along eaves in accordance with building code requirements. NAILING:Use galvanized(zinc coated)roofing nails, 11 or 12 gauge,with at least 3/8"diameter heads,long enough to penetrate through plywood or 3/4"into boards. Use 4 nails per shingle placed in the nail line 7-3/8" below the top edge, approx. 1"and 13"in from each end. Drive nails straight so that nail head is flush with, but not cutting into shingle.surface. NAILING ON STEEP SLOPES:For steep slopes of 21"per foot(60°)or more,use 6 nails per shingle placed as shown below. Ensure that no nail is within 2"of a joint/cutout of the underlying shingle. Seat down each shingle at time of application with three 1"diameter(approx.size and thickness of a quarter)'spots of asphalt plastic cement placed under the shingle 2" above the bottom edge and equally spaced along the shingle. Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the heat of direct sunlight. EXPOSURE: Installed shingles shall have a maximum average exposure of 5-7/8". NAILING-STEEP SLOPES APPLICATION Use she nails as shown. 7 3/8' NAIL LINE G 3/8't El NAILS CEMENT PROPER APPLICATION REQUIRES THAT THE NAILS PENETRATE BOTH THE OVERLAY AND UNDERLAY PORTIONS OF THE SHINGLE PRI Construction Materials Technologies,LLC.6412 Badger Drive Tampa,FL 33610 Tel:813.621-5777 Fax:813-6'Lt-5840 a-mail•materialstesting@priomtcom Website:httpJtwww.0cmtcom IKO Installation Instructions for Asphalt Shingles Page 4 of 5 IKO Hip and Ridge 12 Application Instructions (ASTM D3161, Class F—IKO Hip and Ridge 12) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT,THESE INSTRUCTIONS WILL GOVERN. Cut hip and ridge shingles into thirds, using the perforation marks as a cutting guide. These shingles are designed for a 51/8"(130 mm)exposure.(For a neater appearance,the top of each side of each piece has been factorytrimmed on a 1"(25 mm)taper(see drawing).Bend each piece overthe hip or ridge,and nail 5 5/8"(143 mm)above the butt edge 1" (25 mm) in from each edge, exposing each piece 51/8"(130 mm). Apply hip pieces starting at the lower end of the hip,working up toward the ridge. On hip roofs, apply ridge pieces starting at each end, meeting in the middle. On gable roofs, apply ridge pieces starting at the end opposite to the prevailing wind direction and continue to the other end. Note:To obtain a three-dimensional effect,(which is recommended,but not required),apply hip and ridge shingles double thickness bystacking 2 pieces on top of one another,the lower piece extending about 3/4"(19 mm)further than the top piece(see diagram).The final shingle should be set in cement,and the exposed nail heads of the final shingle should be covered with cement. Prior to application in cold weather, storing the shingles in a heated area will allow for easier bending. NOTE:SHINGLES MUST BE APPLIED PROPERLY.THEY ARE DESIGNED FOR USE AS HIP AND RIDGE SHINGLES ONLY;AND SHOULD NOT BE USED FOR ANY OTHER APPLICATIONS.WE ASSUME NO RESPONSIBILITY FOR LEAKS OR DEFECTS RESULTING FROM POOR APPLICATION OR FAILURE TO PROPERLY PREPARE THE SURFACE TO BE ROOFED OVER, OR FAILURE TO PROVIDE PROPER VENTILATION IN ACCORDANCE WITH MINIMUM PROPERTY STANDARDS REQUIREMENTS.REVIEW ALLAPPLICABLE BUILDING CODES,MINIMUM PROPERTY STANDARDS,AND REQUIREMENTS PRIOR TO APPLYING THESE SHINGLES USING THESE APPLICATION INSTRUCTIONS. 3W 1 ,- (19 M) TAPER Cur n30 mml e3V ttfitmml PRI Construction Materials Technologies,LLC.6412 Badger Drive Tampa,FL 33610 Tel:813-0-5777 Fax:813.621-5840 e-mail:mamdalstestnapricmtcom Website:httplAvW-Pdcmtccm IKO Installation Instructions for Asphalt Shingles Page 5 of 5 IKO Leading Edge Plus Application Instructions (ASTM D3161, Class F—IKO Leading Edge Plus) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT,THESE INSTRUCTIONS WILL GOVERN. 1. Apply any underlayment, eave protection, valley flashings, or drip edges to roof deck as required. 2. Each 39 3/8"x 131/4"(1000 mm x 336 mm)IKO Leading Edge Plus strip is perforated lengthwise for separation into two(2)shingles.Take one IKO Leading Edge Plus strip and fold flat at perforation to separate. 3. Take one of the separated shingles 39 3/8"x 6 5/8"(1000 mm x 168 mm)and remove approximately 20"(500 mm). Install this shingle on the lower left comer of the roof deck, granule side up,with the factory installed sealant adjacent to the eaves.The shingle should overhang the rake edge and eaves by a nominal 1/4"(6 mm)minimum.Fasten the shingle to the roof deck with nails located 3"to 4"(75 mm to 100 mm)from the eave edge and 1"(25 mm) in from each end. 4. Take the leftover 20"(500 mm)piece shingle.Rotate the piece and align it vertically up the rake edge with the factory installed sealant adjacent to the outer edge of the roof.The shingle should overhang the rake edge by a nominal 1/4"(6 mm)minimum.Fasten the shingle to the roof deck with fasteners located 3"to 4"(75 mm to 100 mm)from the rake edge and 1"(25 mm) in from each end. 5. Repeat Steps 3—4 for the right lower corner of the roof deck. NAILING: Use galvanized (zinc coated)roofing nails, 11 or 12 gauge,with at least 3/8"(9 mm)diameter heads, long enough to penetrate through plywood or 3/4"(20 mm)into boards. Use 4 nails per shingle placed 3"to 4"(75 mm to 100 mm)from the eave edge and approximately 1"and 13"(25 mm and 330 mm)in from each end. 6. Apply full-length IKO Leading Edge Plus shingles to the remaining eave edges of the roof deck.Install the shingles granule side up with the factory applied sealant adjacent to the eaves. The shingles should overhang the rake edge and eaves by a nominal 1/4"(6 mm)minimum.Fasten the shingles to the roof deck with nails located 3"to 4"(75 mm to 100 mm)from the eave edge,4 nails per shingle. 7. Apply roof shingles as per the instructions printed on each product's package. Make certain the first course of field shingle lies flush with the edges of the fastened IKO Leading Edge Plus. In this way, the sealant on the IKO Leading Edge Plus shingles will adhere to the first-course field shingles and help keep them from lifting in high winds. PRI Construction MaterialsTechnologies,LLC.6412 Badger Drive Tampa,FL33610 Tel:813621-5/77 Fax:813621-5840 e-mail:matedalstasling@pdcmtoom WebSite:http1Awnv.pricmtcom