Loading...
HomeMy WebLinkAboutProduct Approval LSTILucie ECEIVED B 2 2 2018 NIIANNH-DADE COUNTY Count Permitti DUCT CONTROL SECTION DEPARTMENT O>~REGULATORYANDECONONIIC RESOURCES 11805 SW 26 Street,Room 208 BOARD AND CODE ADN M41STRATTON DIVISION Mmaii,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) ,w. —ogy/economy Iko Industries Ltd. 40 Hansen Rd.S. Brampton,Ontario CANADA L6W3H4 NOV s 2017 SCOPE: St. Lucie C unty, FL This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Maori-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA-shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (in Mann-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this:product or material tested for quality assurance purposes.If this product or material fails to perform in the;accepted-manner,the manufacturer will mcur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is deterinined by Miami:Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code incl the High Velocity a Zo Florida Buildin Code. 3�r,�Gl�l:-Cambridge,Cambridge HD,and Bltmore AR A '= LABEIdNG:Each unit shall bear a permanent label with the manuf whirer's name or logo,city,state and following statement:"Miami Dade County Product Control Approved-,unless otherwise noted herein- RENEWAL ereinRENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change is the applicable building code negatively affecting the performance of this product: TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shalt be cause for termination and removal of NOA. OADVERTLSEPKENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed U by the:expiration date may be displayed m advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by1he manufacturer or its distributors and UJ shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No-14-0603-02 and consists of pages 1 through 4. The submitted documentation was reviewed by Gaspar J Rodriguez. i NOA No.:16-0329.13 CONTR4 Expiration Date: 05/05121 TOR copy Approval Date: 04/21/16 Copy Page I of 4 ROOFING ASSEMBLY APPROVAL Caere; Roofing Sub-Category- Asphalt Shingles Materials: Laminate Deck Tyne- wood SCOPE This approves a roofing system using Cambridge AR,Cambridge HD,and Biltmore AR asphalt shingles mnufitctun)d by IKO Industries Ltd as described in Section 2 of his Notice of Acceptance. PRODUCT DESCRIPTION Product Dimen.4ions Test Specifications Product Descripfion Cambridge 133/4"x 40'/s" TAS 110 A heavy weight,fbeWjass reinforced Manzi aeturing Location W, 2, 3 laminate asphalt shingle. Cambridge RD 13 3/4"x 40'/a" TAS 110 A heavy weight,fiberglass reinforced MwiWacturing Location#l,2,3 laminate asphalt shingle. Brltrnore AR 13 3/4"x 40'/g" TAS 110 A heavy weight,fiberglass reinforced Manufacturing Location W, 2 laminate asphalt shingle. MANUFACTURING LOCATION 1. Kankakee,II, 2_ Wilmington,DE 3. Sylacuaga,AL EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date PRI Construction-Materials Inc. IKO-050-02-01 TAS 100 12/21/09 IKO-076-02-01 TAS 100 02/21/12 IKO-114-02-01 TAS 100 091/25/14 IKO-099-02-01 TAS 100 05/12/14 IKO-096-02-01 ASTM D 3462 09/27/13 IKO-095-02-01 ASTM D 3462 09/27/13 IKO-121-02-01 ASTM D 3462 09/25/14 IKO-100-02-01 ASTM D 3161 (TAS-107) 05/21/14 IKO-115-02-01 ASTM D 3161 (TAS-107) 09/25/14 FM Approvals 3041689 ASTM D 3462 02/23/11 3036971 ASTM D 3161 (TAS-107) 01/04/09 3042673 ASTM E 108 04/12/11 lttADEfi10N1iTY NOA No.:16-0339.13 Expiration Date: 05/05/21 Approval Date: 04/21/16 Page 2 of 4 LumTATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product_ 2_ Shall not be installed on roof mean heights in excess of 33& 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115_ 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail'A',attached_ 5. Nailing shall be in compliance with Detail B',attached. LABELING 1. Shingles shall be labeled with the Miami-Dade Seal as seen below,or the wording"Miami-Dade County Product Control Approved". 4-.77571W C011I►1TY .• •O BUILDING PEWMT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 12 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system M4DECOUNTY NOA No.:16-0329.13 Expiration Date: 05/05/21 Approval Date: 04/21/16 Page 3 of 4 DETAIL A CAMBRIDGE,CAMBRIDGE/HD,BILTMORE AR COURSE LAYOUT 1 —AGE OF ROOF i F� Nota—Roofing Cement not dmwn si#as iayo Thm drm"'s for cm-se Uyout ordy_ See Delad 8 ------------ for nadm and cement Oaoea a dem / THIRD COURSE SECOND COURSE i 9RST COURSE rill % DETAIL B CAMBRIDGF,,CAMBRIDGE HD,BILTMORE AR 'TMJ 7w 8 in- 133 —" /77 8 6 / 5" EXPOSURE END of Tms AccEPTANcE NOA No.:16-0329.13 Eapiration Date: 05/05/21 Approval Date: 04/21/16 Page 4 of 4