Loading...
HomeMy WebLinkAboutProduct Approval (2) 12118/2017 Florida Building Code Online 5t' a � � x �'cwti^ •����A� '�''at t 1�� :� r q Mir, SCIS Home Log In User Registration Hotloplcs Submit Surcharge Stats&Fads Publications FBC Staff I 5C1S Site Map Unks Search d- Horid Product Approval USER,public User - FWti t Approval Menu>Product or Application Search>Application List>Application Mimi FL# FL15054-RS Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer. NewSouth Window Solutions Address/Phone/Emali 4901 oak fair blvd tampa,FL 33610 (513)284.0129 danochsteln@newsouthwindow.com Authorized Signature Vivian Wright rickw@rwbidgconsuitants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Emali Category Windows Subcategory Fixed Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F Schmidt the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ryan I.King,P:E. ° Validation Checklist-Hardcopy Received Certificate of Independence FLIS054 RS CQI.(bt Certificate of lndependence.odt Referenced Standard and Year(of Standard) Stapdard Year AAMA/WDMA/CSA101/I.S.2/A440 2008 AAMA/WDMA/CSAI01/I.S.2/A440 2005 AAMA/WDMA/CSA10I/I.S.2/A440 2011 ASTM E1886 2005 ASTM E1996 2006 ASTM E1996 2008 TAS 201,202,203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Englneer•or Architect FLI yQ54 R5 Egiiiv (a)Eouivalergyyf Standards.odf https://floddabuilding.org/pr/pr app_Otl.aspx?param=wGEVXQwtDquS73Fr2ZyiPISEw9YUwBR2sNTngtn%2fNntk$RPeH7DUOAD/o3d°/a3d Its 12118/2017 Florida Building Code Online Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/12/2017 Date Validated 10/25/2017 Date Pending FBC Approval 10/26/2017 Date Approved 12/12/2017 Summary of Products Go to Page 0 O Page 1./20 F4# Model,Number or Name Description 15054.1 a.DuraGard Fixed Window Extruded Vinyl Direct Glazed"Non-Impact"Fixed Window utilizing a Nall Fin Installation(O configuration) Umits of Use Installation.Instructions Approved for use In HVHZ:No �5054 R5 11 (a)Inst 15054.1.odf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation.Reports - Other:See INST 15054.1 for Design Pressure Ratings,any FL15054 RS AE (a)Eval 15054.1.3df additional use limitations,Installation instructions and product Created by Independent Third Party:Yes particulars. 15054.2 b.DuraGard Fixed Window Extruded Vinyl Direct Glazed"Non-Impact"Fixed Window(0 configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No ELI 5054 RS 11 (a)Inst 15054,2 pdf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other.See INST 15054.2 for Design Pressure Ratings,any FLIS054 R5 AE (a)Eval 15054.2.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15054.3 _~ c.TrustSeries Fixed Window Extruded Vinyl Direct Glazed"Non-Impact"Fixed Window utilizing a Nall Fin installation(0 configuration) Limits of Use Installation Instructions �— Approved for•use in HVHZ:No FLI5054 RS 11 (a)Inst 15054.3.odf Approved for use outside HVHZ*Yes Verified By:Lyndon F.Schmidt,P.E.43408 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15054.3 for Design Pressure Ratings,any E(15054 RS AE !a)Eval 15054.3.odf additional use limitations,Installation Instructions and product Created by Independent Third Party:Yes particulars. 15054.4 d.TrustSerles Fixed Window _ Extruded Vinyl Direct Glazed Non-Impact"Fixed Window(0 configuration) Limits of Use Installation Instructions Approved for use in HVHZ*No Ft.]5054 ei (a)InFt15054,4.ndf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15054.4 for Design Pressure Ratings,any FLI5054 R5 AE (a)Eval 15054.4.odf additional use limitations,Installation instructions and product Created by Independent Third Party Yes particulars. 15054.5 e.5ash11te Fixed Window Extruded Vinyl Sash in Frame Glazed Non impact Fixed Window utilizing a Nall Fin Installation(0 configuration) Limits of Use Installation Instructions Approved for use In HVHZ:No FL15054 R5 11 (a)Inst 15054.5.odf Approved for use outside HVHZ:Yes Verified By:Lyndon F Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third.Party:Yes Design Pressure:N/A Evaluation Reports Other;See INST 15054.5 for Design Pressure Ratings,any FL15054 RS AFfa1 Eval 15054.5.odf additional use limitations,Installation instructions and product Created by Independent Third Party:Yes particulars. 15054.6 f.Sashlite Fixed Window Extruded Vinyl Sash in Frame Glazed"Non-impact"Fixed https:/Ifloddabuilding.org/pr/pr app dtl.aspx7param--wGEVXQwtDquS73Ft2ZyiPIBEw9YUwBR2sNTngtn°/"2(NntkSRPeH7DUOA%3d%3d 2/5 12/18/2017 Florida Building Code Online Window(O configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL15054 R5 11 (a)Inst 15054.6.01 Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15054.6 for Design Pressure Ratings,any FLIS054 R5 AE fa)Eval 15054.6.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15054.7 9.DuraGard Fixed Window Extruded Vinyl Direct Glazed"Impact"Fixed Window utilizing a Nail Fin Installation(O configuration) Limits of Use Installation Instructions Approved for use In HVHZ:No FL'I5054 R5 11 Oa Inst? 054 7 adf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,RE.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See Inst 15054.7 for Design Pressure Ratings,any FLI5054'RS AE (a)Eval 15054,7.12dt additional use limitations,Installation Instructions and product Created by Independent Third Party:Yes particulars. 15054.8 h DuraGard Fixed Window Extruded Vinyl Direct Glazed"Impact"Fixed Window with Flange(O configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL15054 R5 II (a)Inst IS 54.8.odf Approved for use outside HVHZ:Yes Verified By:Lyndon F Schmidt;P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See Inst 15054.8 for Design Pressure Ratings,any FLi5054 R5 AE fa)Eval 15054.8.od( additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15054.91 4600 Fixed Window Extruded Vinyl Direct Glazed"Non-Impact"Fixed Window utilizing a Nail Fin Installation(O configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FLIS054 R5 11 (a)Inst 15QS4.9.Ddf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant;No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other.See INST 15054.9.for Design Pressure Ratings,any FL15054 R5 AE fa Evai 15054 9 odf _additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. 15054.10 �j.4600 Fixed Window T Extruded Vinyl DirectGlazed"Non-Impact"Fixed Window with Flange(0 configuration) Limits of Use Installation Instructions Approved for use in HVHZ;No FL15054 R5 11 fa)Inst 1S054,10.odr Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:"N/A Evaluation Reports, Other-See.Inst 15054;10 for Design Pressure Ratings,any FLIS054 R5.AE (a)Eval 15054.10.0f additional use.limitations,Installation instructions and product Created by Independent Third Party:Yes particulars. 15054 11 k 4650 Fixed Window Impact Extruded Vinyl Direct Glazed"Impact"Fixed Window utilizing a Rated HVHZ Nail Fin Installation(O configuration) Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL15054 R5 II (a)Ins(,150 4A I1ydf Approved for use outside HVHZ:Yes Verified By:Lyndon E Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15054.11 for Design Pressure Ratings,.any FL15054 R5 AF (b)Eval 15054 11.pdf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes i particulars 15054.12 1.4650 Fixed Window-Impact Rated Extruded Vinyl Direct Glazed"Impact"Fixed Window with i HVHZ Flange(O configuration) r Limits of Use i Installation Instructions Approved for use in HVHZ:Yes FLI50 4 R5 11 (a)Inst 15054,12,odf Approved for use outside HVHZ:Yes Verified BY: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15054.12 for Design Pressure Ratings,any FL15054 RS AE (b)Eval 15054,12, df additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. https:l/floddabuilding.orglpr/pr app dtl.aspx?param--wGEVXQwtDquS73Fr2ZyiP18Ew9YUwBR2sNTngtn%2fNntkSRPeH7DUOA°/"3d%3d 3/5 - — - - 12/1*/207 Florida Building Code Online 15OS4.13 m.9600 Fixed Window Extruded Vinyl Direct Glazed"Non-Impact"Fixed Window utilizing a Nall Fin Installation(D configuration) Limits of Use Installation Instructions Approved for use In HVHZ:No FLI 5054_RLILial Ing 15P§Aj_Lgft Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact RestsUnt:No Created by Independent Third Party;Yes Design Pressure:N/A Evaluation Reports Other.See INST 15054.13 for Design Pressure Ratings,any FLIS054 R5 AE (a)Eva) 15054,13.pdf ,additional use limitations,installation instructions and product Created by Independent Third Party.Yes 15054.14 n.9600 Fixed Window Extruded Vinyl Direct Glazed"Non-Impact"Fixed Window with I Flange(0 configuration) Limits of Use Installation Instructions Approved for use In HVHZ:No FLIS054 R5 11 (a)Inst 15054.14.pdf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmildt�P.E.43409 Impact Resistant:No Created by.Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST IS054.14 for Design Pressure Ratings,any FLI 054 R5 �,E (a)Evg!l 15054,14,pd additional use limitations,Installation Instructions and product Created by Independent Third Party.Yes IS054.15 o.'9650 Fixed Window-Impact Extruded Vinyl Direct Glazed"Impact"Fixed Window utilizing a Rated Nail Fin Installation(0 configuration) Limits of Use Installation Instructions Approved for use In HVHZ,.No FL15054 R5 11 (a)Inst 15054.1S,Pdf Approved for use outside HVHZ:Yes Verified By:Lyndon R Schmidt,P.E.43409 Impact Resistant.,Yes Created by Independent.Third Party:Yes Design Pressure:N/A Evaluation Reports Other.See INST 15054.15 for Design Pressure Ratings,any FLI 5054RS AE (a)Eval 1�054,15.pdf additional use limitations,Installation Instructions and product Created by Independent Third Party,Y6s p.9650 Fixed Window-Impact 15054.16 udd Vinyl Direct Glazed"Impact"Fixed Window with iRated__ Flange(0 configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL15054 R5 11 (a)Inst 15054.16,1)df Approved for use outside HVHZ:Yes Verified By:Lyndon K Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15054.16 for Design Pressure Ratings,any FL35054 RS AE (a)Eval 15054.16,ndf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes 15054.17 rq.96SO Fixed Window-Impact Extruded Vinyl Direct Glazed"Impact"Fixed Window utilizing a Rated-HVHZ Nail Fin Installation(0 configuration) Limits of Use Installation Instructions Approved for use-in HVHZ,Yes FLI5054 IRS 11 (a)Inst 15054,17,odf Approved for use outside HVkZ:Yes Verified By:Lyndon K Schmidt,P.E.43409 Impact Resistant..Yes Creat'ed by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other.See INST 15054.17 for Design Pressure Ratings,any FLIS054 RS AE (a)Eval 15054.17.pdf additional use limitations,Installation Instructions and product Created by Independent Third Party:Yes 15054.18 r.9650-Fixed Window-Impact Rated Extruded V'Inyl Direct Glazed"Impact"Fixed Window with Limits of Use Installation Instructions Approved for use In HVHZ:Yes F�15054 R5 ll'-(a)Inst 15054.1g.pot Impact RiesiMint;Yes Created by Independent Third-Party:Yes DesIgn.Pressure:'IN/A - Evaluation Reports Other:See,INST 15054.18 for Design Pressure Ratings,any FL15054,RS AE (a)EvIII 15054,18,DOf additional Use limitations,Installation Instructions and product 'Created by1ndependerit'Third Party:Yes ISCS4.19 s.4800'Twin Mulled"Common lamb" Extruded Vinyl Direct Glazed"Non-Impact"Integral Mulled Fixed Window 'Common Jamb'Twin Fixed Window with Flange(0/0 Vertical or Horizontal configurations) Limits of Use Installation Instructions Approved for use In-HVHZ.-No FLI 5054 R5 11 (a)Inst 15CS4,19,pdf Approved for use outside HVHZ:Yes � v"norm By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:NIA Evaluation Reports Other:See INST 15054.19 for Design Pressure Ratings,any PLIS054 R5 Ar (a)Fval 15054.19,D(Jf additional use limitations,Installation Instructions and product Created by Independent Third Party:Yes *m 12/18/2017 Florida Building Code Online 15054.20 t.4800 Mulled"Common Jamb" Extruded Vinyl Direct Glazed"Non-Impact"Integral Mulled Fixed Window "Common lamb"Triple Fixed Window utilizing a Nail Fin Installation(O/O/O Vertical or Horizontal configurations) Limits of Use Installation Instructions Approved for use In HVHZ:No FL15054 R5 II (a)Inst 15054.20,pdf Approved for use outside HVHZ:Yes Verified'By:Lyndon F.Schmidt,P.E.43404 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15054.20 for Design Pressure Ratings,any FLI5054 R5 AE (a)Evai 15054.&IZdf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. Go to Page �'+► O Pagel/20 0 ED El Contact Us n 2681 Blair atone Road.Tallahassee Ft 32399 Phone:8,S,Q-487-1824 The State of Florida is an AA/EEO employer.Coovrioht 2007.2013 State.of Florida.::Plivacv Siatemen ::A essibility Statemgnt::Refund Statement Under Florida law,email addresses are public records.if you do not want your a-mall address released in response to a pubtk-records request,donot send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.27S(i),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide.the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,FS., please crick here. Product Approval Accepts: i Credii Card Sate C https:tt loridabuiiding.orglpr/pr app dti.aspx?param--wGEVXQwtDquS73Fr2ZyiPI$Ew9YUwBR2sNTngtn%2fNntkSRPeH7DUOA%3d%3d 515 R w R. W Building Consultants, Inc. B Consulting and Engineering Services for she Building Industry C P.O.clone 23O Vdriao4 PL 33393 Pbooa 813AM9197 Fbrida Bmd of PmtWs1wW Enebmn Cal kaft of Audw hmdon No.9813 Cer icate of fndependenee RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company manufacdnring or distributing the product or in any other ea ft involved in the approval process of the product named m the accompanying Florida Product Approval. Lyndon F.Schmidt,P.E. FL No.43409 October 2,201 T RAA-A Product-Job-Lab-L1ata1A-Plod&•Pmduct Approv*lFioridn Smmwd PoarftMlm HddrxslCarltkate of Indepaddnoedoo Shoat i of E c '"'Newsouth Li ! WINDOWSOLLMONs �,� r t x..._ __� bi'tAAX.OVERAtt FlttWtDili ''',``�r�rrll*• 4901 Odf;FaFFB1vd.,Tampa,FL 33610 60 MAX ovfRAutTtAMEwlDTN� i3 oS 5d; 9650 Fixed Window Impact Rated HVHZ a w/ Flange GENERAL NOTES 1. This product has been evotuated and Is in compliance with the 6th Edition(2017(Rorlda Building Code(HBC(structurat requirements including ihe'Kagh Velocity Hurricane Zara' & � a ts;; a u5i 2 Product anchors shat be as Wed and spaced as shown on detois.Anchor embedment to n a p w base moterld stxI be beyond wall dressing or stucco. 11 4 3. When used in the'14VHr this product complies with Section 1626 of the Florida Buk*V Code d and does not require an impact resistant coveting. U f 4. When used in areas osMe of the IWW regkMng wind borne debris protection this product Z comptim with RBC Sections M.1I&R3012.12 and does not requuite an Impact resistant ^�4 coveting.Ttds product meets missile leveM and includes Wind lone 4 as defined in ASTM r S E7996 and RBC Secfions 1609:1.2214 R301.21.2.1, n CS o 5. For 2%stud framing construction.onchorlig of those units shat be the same as that shown for — 2x buck masonry construction aio 6. Site cor ditlors that devlate from the defoh of this dmv&g require further engfneedng onolysis to by a lcensed englleef a regatered achitect. . (OTE VERMAL OMENTATION SNOwN INORLtOW AL OMMATION ALSO APPROVED) o 7. This product meets water intitratbnrequirements for'HVHP. MMCVMALE; MAX OVFRAIE; MAx GLASS: tWIGNMMURE 2 RANGE FRAME: DAY111E ti* M TABLE OE CONTENTS DIMENSION DIMENSION 01MENSIOxmE ►Od. ;.- NEG.SHEET# DESCR17FWN i T I h ts,d n pmssur es 6,general(totes 37.1"X 73.1' SLD'X 7W 31.75-X i7.75� G1 +70.0 -70.0 e 2 Horizontal cross sections a se: 6126175 : 3 Horizontal cross sectio s 41-1`X 65.1' i0A X 64.0- SS75-X 71.75' G2 +60.0 -60.0 suu N.T.S.N. s 4 o am ell JK m' 5 Frame ano.a adz M14L 01r., lFS ° 6 Bil at mat ,components d,gkizing details Note:This product Is not approved for use above 30 feet In the"HVHr. FL--15054.18 ° N 4fl.� t or 6 a it i a =wj s 1t11r�1'� rkfrrrrlu''',` N N NI v N r N i a V. In 16 C}- 94 N r w • M � Q r A AN ►atter""°-3PMNrM�r� �yry.WMrtrrrw ..�... r i RworJt ���� t s / tKom 12 C ' #* c • f n , gal 14.11 3 4 too=/ 2 44JawMnaaa>.wwNy MOM �� Wu ! . uO+nw�rlri'11ue +o E _ MAX.DOM PRESSURE FOR'AMMAN �► tem Ind C ANCHORWG LCLC ON SHOWN ON THISSHEEET +• C *65 PSF(UP TO W X 7r FRAME SQA I ±W PSF(UP TO 6W X W FRAME SIM t si t 1! tl � .• t s E Wpmera Pyr.) lam .rt 1 ! A���Qj�fICIIOMsoft k t is .V��irsonptlNWAOCMln 4if i■irwcv�wueicn ti—t3o3t.td � I ' �cr.�..r..n�h.w�n�•naw.wl.n+Mra+M w��.+�•a�+++/+.s�'amnn�lx+./+ss+: !+ N pf 4 14 oil �rtii�w.ac. tMa� _ Iowa avow 12.W�ff Nls6o�rtl' �.�arwslt �4�i • try*"Mw n.areae �, f n t T 6UGC YY ws.s.Mw 813M \a a ANCNONlMD �a�M.sna sol• w.wrnnr aow.t.M..�a � n-r 004 Q3'►St�rl-'td NlllPmMy"oJ 1'M�db1Y+P�J pErxxri�»Mti+iW MI�oMf�l i S!T wt wei d JAI drt M' yr m *r.Lw .t i AA-1 &A IM A Mi VONZOW • �MialO--Wa*R7 v 1v�o++�a�a�•o+grwrw,�7lw7cvN.wr..w�ralGw+Du�gAo�+� �a��Nuow�'�N1fR+�+�a QIP��'Wi�41 aaar'i�+a�rrrJstM�rw�+n+�e�fa�a��aoollp�� 431SNNsr" 3 ti rQ� y a `- AMOM . t VOME awl= y x�rw xc c x AWi0°""' a aus� x xoxi Y !� wrocwrai�mMa tl 1 d xxMxt N tN #_ Bill, � �.• * nary , 'v Nw�p Ana runa+n•rrC rw+uq p•r��os p eta�e va saw SIR=Ob2wv i mm � Dow u►syMYils rAN�M//)��/, i'MO[ilMl!0?a s «y 'ONy'fY1Kl7M1100 ow--�A '` � NJ� i ,��ti�tiumu�p� pan w y. • .�JOCYlwgalo0 12 12 Ll -� — a s oil xx € it ''t ��_� • l'1Mt[rAiS+t(IRt�YIOSPWMPrO•y1p{If6aPl�rdNiwrMMl4i•NIl�Nws•MIMW�3•pM�Y R W R W Building Consultants, Inc. B Consulting and Engineering Services for the Building Industry C P.O.Box 230 Votrico.Fl.33393 Plume 813.659.9197 Florida Board or Proressional Fsgiaem Certificate orAudaoriaation No.9813 Product IFZ-15054.18 Date: October 12,2017 Product Category Sub Category Manufacturer Product Name NewSouth Window Solutions 9660 Fixed Window Windows Fixed 4901 Oak Fair Blvd Impact Rated-HVHZ Tampa,FL 33610 wl Flange (613)264.0124 Scope: Product Evaluation report Issued by R W Building Consultants,Inc.&Lyndon F.Schmidt,P.E.(System ID#1998)far NewSouth Window Solutions,based on Rule Chapter No.61 G20-3.Method 1 D of the State of Florida Product Approval. Dept.-of Business&Professional Regulation. RW Building-Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Llmitatiorrs. 1.This product has been evaluated and is in compliance with the 6th Edition(2017)Florida Building Code(FBC)including the"High Velocity Hurricane Zone"(HVHZ). 2.Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3.When used in the"HVHZ",this product complies with Section 1626 of the Florida Building Code and does not require an impact resistant covering. 4.When used in areas outside of the"HVHZ"requiring wind bome debris protection,this product complies with.FBC Sections 1609.1.2& R301.2.1.2 and does not require an impact resistant covering:This product meets missile level"D"and includes Wind Zone 4 as defined in ASTM E 1996 and FBG Sections 1609.1.2.2&R301.2.1.2.1. 5. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. 6.Site conditions that deviate from the details of drawing FL-15054.18 require further engineering analysis by a licensed engineer or registered architect. 7. This product meets water infiltration requirements for"HVHZ". 8. See drawing FL-15054.16 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Sinned by ATi C9933.05-401-18 TAS 201;202,203-94 Architectural Testing,Inc. Shawn G.Collins,P.E. TEL 02031566 TAS 201.202,203.94 Testing Evaluation Labs. William B.Shelton,P.E. 2. Dade County NOA Materials 15-1201.11 Saliex PVB Interlayer(Eastman Chemical Co.) 14-0916.11 SentryGlas interlayer(Kuraray) Drawing No. Prepared by t�11@98SCi68d�gJ � Signed&Sealed by SC,HA4/0 if % 3 No.Ft:15054.18 RW Building Consultants,Inc.(CA#9813) `®`°%y f GENS .)`�8f ndon F.Schmidt,,P.E. 4. Calculations Prepared by .�` «•ti' S¢rftned&Seaied by Anchorin RW Builth Consultants,Inc.(CA No 49409 9 n9 ( ) :• �iyrglon F.Schmidt,P.E. ASTME 1300 Glass Load Lyndon F.Schmidt,P.E. _ 5. Quality Assurance %'t3 Certificate of Participation issued by National Accreditation and Management+„ STATE OF ." Institute,certifying that NewSouth Window Solutions Is manufacturing '���5*•••'�L .. 4 •• r products within a quality assurance program that complies with IS0AEC °irCfi%. R •' 17020 and Guide.53. °°O��"^�U N/�.a t`tie Lyndon FlE No. P.E. Schmi 1011212017 Sheet 1 of 1 12115/2017 Florida Building Code Online a 2 f rs { { BCIS Home Log In i User Registration Hot Topics' i Submit Surcharge Stats B Fads Publications FBC Stall ! BaS SRe Map Links Search, FI nda Product Approval Yz USER:Public User Product Annrovai M@nu>Product or Application Search>Application u5t>Application Mail FL# FL168S1-RS Application'type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer NewSouth Window Solutions Address/Phone/Email 4901 oak fair blvd tampa,FL 33610 (513)284-0129 danochstein@newsouthwlndow.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Emall Category Windows Subcategory Single Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-.Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F Schmidt the Evaluation.Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration pate 12/31/2018 Validated By Ryan J.King,P.E. Validation Checklist-Hardcopy Received Certificate of Independence FL16851 R5 COI (b)Certificate of lndepe�ndence.odf Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA101/I.S.Z/A440 2011 AAMA/WDMAJCSA101/I.S.Z/A440 2008 ASTM E1886 2005 ASTM E1996 2006 ASTM E1996 2009 TAS 201,202,203 1994 Equivalence of Product Standards Certified By Sections from the Code https:/Moridabuiiding.org/pr/pr app_dti.aspx7param=wGEVXQwtDgtmmTSTNdVPsacfoUCDIJOgiPTYa/a2fRt2LFFzMP8ymMmOQ*/a3d%3d 116 12115/2017 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 10/12/2017 Date Validated 10/27/2017 Date Pending FBC Approval 10/29/2017 Date-Approved 12/12/2017 Summary'of Products Go to Page 0 0 Pagel/20 0 FL# Model,Number or Name Description 16851.1 a.9400 Single Hung Window T Extruded Vinyl"Non-Impact"Single Hung Tilt Window New Construction with Nail Fin(0/X-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R5 11 (bl Inst 16851.1.12d( Approved for use outside HVHZ:Yes Verified By:Lyndon F Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.1 for Design Pressure Ratings,any FL16851 R5 AE (b)Ey-al 16851.1,r)df additional use limitations,Installation instructions and product Created by Independent Third Party:Yes particulars. 16851.2 -_.__.... b.9400 Single Hung Window Extruded Vinyl"Non-Impact"Single Hung Tilt Window with Flange(O/X-configuration) Limits of use Installation Instructions Approved for use in HVHZ:No FL16851 R5 II (b)Inst 1 851,2.od( Approved for use outside HVHZ:Yes Verified By:Lyndon R Schmidt,RE.43409 Impact Resistant:No Created,by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.2 for Design Pressure Ratings,'any FL16851 R5 AE (bi EvaI 16851.2.odf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. 16851.3 c.9450 Single Hung Window Extruded Vinyl"Impact"Single Hung Tilt Window New Construction with Nail Fin(O/X-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL168 1 R5 11,(bInst 16851,3.ndf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.3 for Design Pressure.Ratings,any FL16851 R5 AE (b)Eval 16851.3.odf additional use limitations,Installation Instructions and product Created by Independent Third Party:Yes particulars. 168514 rid,9450 Single Hung Window Extruded Vinyl"Impact"Single Hung Tilt Window with Flange (0/X-configuration) Llmits of Use Installation Instructions Approved for use In HVHZ:No FL16851 RS i1 fbl Inst 168511.4.odf Approved for use outside HVHZ:Yes Verified By:Lyndon F,Schmidt,P.E.43409 Impact Resistant)Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 168S1.4 for Design Pressure Ratings,any FL16851 R5 AE (b)E,val16851,4.pgf additional use limitations,Installation Instructions and product Created by Independent Third Party:Yes particulars. 16851.5 e.9450 Single Hung Window Impact Extruded Vinyl"Impact"Single Hung Tilt Window New Rated-HVHZ Construction with Nail Fin(O/X-configuration) Llmtts of Use Installation Instructions Approved for use in HVHZ:Yes Et 1685,E R5 11 (bl Inst 16�5.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes { Design use N/A Evaluation Reports i Other:See INST 16851,5 for Design Pressure Ratings,any FLIG851 R5 AE (b)Evei 16851S.odf !additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. 16851.6 f 9450 Single Hung Window Impact Extruded'Vlnyl"Impact"Single Hung Tilt Window with Flange Rated-HVHZ (01X­configuration) Limits of.Use Installation Instructions https://floridabuilding.org/pripr_app dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsacfoLiCD[JOgiPTY%2fRt2LFFzMP8ymMmOQ%3d%3d 215 12115/2017 Florida Building Code Online Approveddfor use in HVHZ:Yes FL16851•R5 11 (b)Inst:i6851.6.odf Approved for use outside HVHZ:Yes Verified 6y:Lyndon F.-Schm(dt,•RE.43409 Impact Resistant:Yes Created,.byIndependent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 1,6851.6 for Design Pressure Ratings,any FL16851'RS AE (b)Eval 16851.6.adf additional use limitations,Installation Instructions and product Created.by Independent Third Party:Yes particulars, 16851.7 g.4400 Single Hung Window Extruded Vinyl"Non-Impact Single Hung Window New Construction with Nail Fn(O/X-configuration) Limits of Use Installation Instructions Approved for use In HVHZ:No FI.16851 R5 it 1111 Inst 16851.7.ndf Approved for use outside HVHZ:Yes Verifled By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.7 for Design Pressure Ratings,any F06851 R5 AE (b)Eval.I6851,7.D0f additional use(imitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.8 h.4400 Single Hung Window Extruded Vinyl"Non-Impact"Single Hung Window with Flange (O/X-configuration) Limits of Use Installation Instructions. Approved for use In HVHZ:No FL16851 R5 11 (b1 Inst 168 1.8,Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,RE.43409 Impact Resistant:No Created.by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.8 for Design Pressure Ratings,any FL.16851 R5 Ae (b)'EyAl 15851,8,Ddf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. 16851.9 1,4450 Single Hung Window Extruded Vinyl"Impact"Single Hung Window New J�— Construction with Nail Fin(O/X-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 its II (b)Insk 168 1.9.Ddf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created.by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.9 for Design Pressure Ratings,any F1851 PS AE (b)Eval 16851 9.odf additional use limitations,installation Instructions and product Created by Independent Third Party:'Yes particulars. 16851.10 J.4450 Single Hung Window Extruded Vinyl"Impact"Single Hung Window with Flange(O/X •configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 RS-11 (b)Inst 16851.10.Ddf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.10 for Design Pressure Ratings,any FL16851 R5 AE (b)Eval 16851,10.adf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851 11 k 44SO Single Hung Window Impact Extruded Vinyl"Impact"Single Hung Window New I Rated-HVHZ Construction with Nail Fin(O/X-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL1685I R5 11 f6l Inst_1e851 1l.ndf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 I Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.11 for Design Pressure Ratings,any FL16851 RS AE (b)Eval'16851,11,pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.12 i.4450 Single Hung Window Impact Extruded Vinyl Impact"Single Hung Window,with Flange(O/X Rated-HVHZ configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15851 R5 II-(b)Inst 16851,12.Ddf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.12 for Design Pressure Ratings,any FL16851 R5 AE (bl Eval 16851.12.odf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. 16851,13 m.4000 Twin Single Hung Window Extruded Vinyl"Non-Impact"Twin Integral,Mulled Common Jamb Single Hung Window New Construction with Nail Fin(DIX I Q/X-configuration) https:/Ifloridabuilding.org/pr/pr_app_dU.aspx?param--wGEVXQwtDgtinmTSTNdVPsacfoL(COIJOgIPTY%2(Rt2LFFzMPBymMmOQ°/o3d%3d 3J5 1211512017 Florida Building Code Online Limits of Use Installation Instructions Approved for use In HVHZ:No FL16851 _R5 11 (b)Inst 16851,I3.odf Approved for use outside HVHZ:Yes Verified By:Lyndon F Schmidt,P.E.43449 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other.See INST 16851,13 for Design Pressure Ratings,any FI,1.6 51 RS AE (b)Eval 16851,13.0df additional use limitations,installationinstructions and product Created by Independent Third Party:Yes particulars. 16851.14 n.4000 Twin Single Hung Window Extruded Vinyl"Non-Impact" twin Integral Mulled Common Jamb Single Hung Window with Flange(O/X I DIX- configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 RS 11 (b)Inst 16851.14.pdf Approved for use outside,HVHZ:Yes Verified By:Lyndon F Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.14 for Design Pressure Ratings,any FL16851 R5 AE (bl Eval 16851.14.pdf additional use limitations,Installation instructions and product Created by Independent Third Party:Yes particulars. 16851.15 o.4000 Triple Single Hung Window Extruded-Vinyl"Nan-Impact"Triple Integral Mulled Common Jamb Single Hung Window New Construction with Nall Fin(O/X I DIX I DIX-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851. R5 I1 (ti)Inst 16851.15.odf Approved for use outside HVHZ:Yes Verified By:Lyndon F Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:.See INST 16851.15 for Design Pressure Ratings,any FL16851 RS AE (b)Eval 16851.15.pdf additional use limitations,Installation Instructions and product Created by Independent.Third Party:Yes particulars. 16851.16 p.4600 Twin Mulled Single Hung/ Extruded Vinyl"Non-Impact"Twin Integral Mulled Common Picture Window Jamb Single Hung/Picture Window New Construction with Nall Fin(O/X 10-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL161 51 R5 I} (L)Inst 16851.16,01' Approved for use outside HVHZ;Yes Verified By:Lyndon F,Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.16 for Design Pressure Ratings,any FL16851 R5 AE (b)Eval 16851.16 odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.17 q.4600 Twin Mulled Single Hung I Extruded Vinyl"Non-Impact"Twin Integral Mulled Common Picture Window Jamb Single Hung/Picture Window with Flange(0/X 10- configuration). Limits of Use Installation Instructions Approved for use in HVHZ:Na FLI6851 RSA II (tr}Ins(16851,17,01' Approved for use outside HVHZ:Yes Verified'.By:Lyndon F.Schmidt,RE:43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.17 for Design Pressure Ratings,any FL16851 RR5 AE 1b)Eval 16851,17,pdf additional use limitations,Installation instructions and product Created by Independent Third Party:Yes particulars. 16851.18 r 4800 SH/SH/SM Triple Single Extruded Vinyl Integrally Mulled Triple Single Hung Windows Hung with Flange; (O/X I O/X I 0/X configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R5 II (b)Inst 16851,18.pdf Approved for use outside HVHZ:Yes Verified By:Lyndon F Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.18 for Design Pressure Ratings,any FL16851 R5 AE (bl Evgj 16851.18,Pdt additional use€imitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851 19 s.4900 SH/SH-Twin Single Hung Extruded Vinyl Integrally Mulled Twin Single Hung Windows with Flange; (0/X I 0/X configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R I c Inst 16$51.19,pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST'16851.19 for Design Pressure Ratings,any FLIG8;I RS AE (ti}Eyal I kR5Lj3.ad( Created by Independent Third Party:Yes haps://floridabuilding.org/pr/pr app dtl.aspx?param--wGEVXQwtDgtmmTSTNdVPsacfoL€CDIJOgiPTY%2fRt2LFFzMP8ymMmDQ%3d%3d 415 12/15/2017 Florida Building Code Online additional use limitations,Installation Instructions and product ] ------ particulars. 16851 20 It.4900 SH/SH/SH-Triple Single Extruded Vinyl Integrally Mulled Triple Single Hung Windows Hung with Flange;(O/X i O/X I O/X configuration) Limits of Use Installation Instructions Approved for use In HVH2:No 0 651 R5 it tci Inst 16851.20.01' Approved for use outside HVH2:Yes Verified By:Lyndon F Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.20 for Design Pressure Ratings,any FI-16851 R;„y AE (b)Eval 16851 20.Ddf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. Go to Page Q O Page 1/20 0 ED ED contact Us::2601 Blair Stone Road.Tallahassee EL 32329 Phone:650-487-1824 The State of Florida Is an AA/EEO employer,r_oavriaht 2007.2013 State of Floridn.::privacy.statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.if you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls provided may be used for offldal communication with the licensee.However email addresses are public record.It you do not wish to supply a personal address,please provide the Department with an small address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please dkk blr_t. Product Approval Accepts: Fag gal MW Credit Card Safe httpsJ/foridabuilding.org/pripr_app_dU.aspx?param=wGEVXQwtDgtmmTSTNdVPsacfoLiCDiJOgIPTY%2fRt2LFFzMP8ymMmGQ°/a3d%3d 5/5 R w R. W Building Consultants, Inc. B Consulting and Engineering Services for the Building Industry C P.O.Dft 230 VAMM FL 33393 Plane$13.6599197 Florida Bmr,d ofPMfessk= Enoww CeM iate of Authowi W Ido.9613 Ce f ware Of ht*j1endeam RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor wilt.acquire financial interest in the company manufhcturing or distributing the product or in any other entity involved in the approval process of the product named in the accompanying Florida Product Approval. Lyndon F.Schmidt,RE. FL No.43409 October 292017 RM-A Product•Job•Lab-L Tsts%A-Ftodh•Product AppmvalstFto"Seamed PoaWWhn Hoidaslcatof bde*WftwAm Sheet i of 1 - mewhuth _ 65'MAXOYQtAWF1ANGEYR[aTtt ��. ..• .... `_ f� WTNDOWSOWTIONS 5!'MAXOYEBAUMAMEW1aTH S0..' I* ����.(�° 7 4901 Oak Fair'Blvd_.Tampa,FL 33610. ! 4 9450 Single Hung Window Oa �it IMPACT RATED - HYHZ � w1 Flange W GENERAL NOTES z ! i? t. This product has been evaluated and is in comptance with the 6th Edition o 8 (2D]7)fiarido SuBding Code(Foci,including the'H'igh Velocity Hurricane l Zone'(HVtiZ). - i 7- Product anchors shod be as listed and spaced as shown an detoits.Anchor � A embedment to base material shot be beyond wat dressing or stucco. n W ^ 3. When used in the'HVHr,this product compBes with Section 1626 of the Florida H r Budding Code and does not require an impact reststantcovering. 3t , a. For 2x stud fro g o Z w o H 3 ming construction,anchatng of these units shxat be the some as n that shown for tat tuck masonry construction. 10%8o 5. Site conditions that deviate from the detai$of this drawing require further W engineering analysis by a kensed engineer or registered architect. aA C 'MAX.OVERAiL MA WWRAt[ 'MAX MAX tABLF OF CONTEM3 DAY U1E DAl 111E GLASSMIGNPRE3SthRE o SNEFTi OESCd17tON FLANGE FRAME: DtA1E dA t>tMENSlON' ME n 1 Typical elevot ons, pressures 3 genera!notes DIMENSION DIMENSION (OPPAIM 'iMW „ ►OS NEG we 2119114 2 Verticil d horizontal cross sections 35.0'X 77A' S4.O"X MA' A7.W x 34.3e' 0.7S x 34X Gl,G2 +55.0 -65.0 scAm* N.T.S. s 3 Vertical A txximniot cross sections o.��: JK 5 4 Buck 3 frame anchoring b 5 38r X Qr 37R'X d= 3011 x 27-W 32.73'x 27X G1.G2 +6S.0 -85-0 aK v LFS 3 oroawa w, d b BBI a materia and gksdng dela Note:fiB product.when d with Gt gladng.ES not approved for use above 30 feet In!he'li1MZ'. FL-161151.6 651.6 i; sKa 1 or 6 O i / ••• + � � �� t��tjllplri N1\ t t � 10 t ` . z x ,� is • � ,spa+ C 1 G 1� 4 ti4t 5 s � 1 1�`y •�� , � •�...:. _ to :.L. � 09 It It 19 Le kw cc BMSINDNMMNMWMONMDWPan Sam lim—MAMANWIN Big m L i pt x ! 1 0 L ® D l V r O -vein wvaMM-mO DW&UMN YA7 IF IOL Q vo 3i! Ag MOON R L!<trrOrC1r 3wt.+w 9 .rtes v*AovpA rocs me IN Ban am Q Ll o 'OMI'lSUlltl'YfO100 0lrQfll� 1 L ■ .i+ . ••••�lul lel ����� rote►wl� 1 ; L�LI�Atollti�•�••• raw At • •S r� all _ j! IE N �S LiMRW'It•WpOGIistM +O.>%MeftWDc•M11��MIOrMeY�w41-NMMIIIf+d*+IMMY�iAllsigAll R1��YIViMwiM�NW�IWAIID{M•1bYlWiio�4PMMMlIQ7iy�IMrgIE•DM�¢yb•1�i[�7)V47�SSWrFF2 ?2r aw �C7Z all=P�:= mgr sre • � w o 4i► M rxr z�r ociew Man? gg aotr I./ , IIa4f111 " 1kOWANNO MWOW �} WWOI?luftw TO f1N y SNGEf MRrYi tl71DOiY T.aull �I � 3 � • .c n.anro� h, y Y r =lM �"4SL�Li�il¢ MW o u m avru,jt�rVrr!r yrN��� L b 7'y11 Pm ow X.70 vYt1N,R"M r FM Ir a sex /Rrt 4A rl&MIS NOT*•.w.mama"m CDiwatomm irr. . oa�o�aa�aaoaQaa"aaac000��o��aoe �J f' 1 • � V .1� • i• L - R T R 1 1 ��E�1L`riF]!Tt:!^']"_Few'✓�'��1Ta_i ��, _ R R W Building Consultants, Inc. W Consulting and Engineering Services for the Building Industry D P.O.Sox 230 Vatriw,FL 33595 Phm 813.659.9197 17 C Florida Board of Professional Engineers Certificate of Authorization No.9813 ProditclEvahiation Report Report s Date. O 017 Product Sub Category Manufacturer Product Name Category NewSouth Window Solutions 9460 Single Hung Window Windows Single Hung 4901 Oak Fair Blvd Impact Rated-HVHZ Tampa,Ft.33610 wf Flange 613 626.6000 Scope: Product Evaluation report issued by R W Building Consultants,Inc.&Lyndon F.Schmidt,P.E.(System ID#1998)for NewSouth Window Solutions,based on Rule Chapter No.61G20-3,Method 1 D of the State of Florida Product Approval, Dept.of Business&Professional Regulation, RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial Interest in the company manufacturing'or distributing the product or 16 any other entity involved in the approval process of the product named herein. itmffattons: 1.This product has been evaluated and is in compliance with the 6th Edition(2017)Florida Building Code(FBC)Including the"High Velocity Hurricane Zone"(HVHZ). 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3.When used-in the"HVHZ",this product complies With Section 1626 of the FBC and does not require an impact resistant covering. 4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions.that deviate from the details of drawing FL-16851.6 require further engineering analysis by a licensed engineer or registered architect. 6.See drawing FL-16851.6 for.size and design pressure limitations. SupporUng Documents: 1. Test Report No. Fest Standard Tasting Laboratory. Sinned by C9937.03401-18 TAS 201,202,203-94 Architectural Testing,Inc. Shawn G.Collins,P.E. TEL 02031487 TAS 201,202,203-94 Testing_Evaluation Lab. William B.Shelton,P.E. TEL 02031566 TAS 201,202,203-94 Testing Evaluation Lab. William B.Shelton,P.E. TEL 02031722 TAS 201,202.203-94 Testing Evaluation Lab. William B.Shelton.P.E. 2. Miami Dade NOA Materials Testing 17-0712.05 Saflex•PVB Interlayer(Eastman Chemical Co.) 3. Drawing No. Prepared by Signed&Sealed by No.FL-161351.6 RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. 4. Calculations prepared by Signed&Sealed by Anchoring RW Building Consultants,ine (CA#9813) Lyndon F.Schmidt,PX. ASTM E1300 Glass Load Lyndon F.Schmidt,P.E. ,���gEtcRttDA�Qy�#�� 5. Quality Assurance f��,�.•�;SW�� Pd�, Certificate of Participation issued by National Accreditation and Management .e� .e'„\G E N Institute,certifying that NewSouth Window Solutions is manufacturing •o Nrr 43409 products within a quality assurance program that complies with ISO/IEC d 17020'and Guide$3. -u w � w Ypa STATE 0 O.R IIDA.���t�� rf dts°roc NA1- e`er LyndonFL PE No.43409 1011212017 Sheet 1 of 1 12126/2017 Florida Building Code Online r • int n x �m � d BCIS Home Log In I User Registration HotTJpics i Submit Surcharge ) Stats 6 Facts i Publications rBC Stall ( SCIS Site Map I Links I Search .I bProduct Approval USER:Public)herd 7 - dtf w-,i Product Anoroval menu>Product or Aoolication Search>Aeoticotion List>Application ttetail n" M FL* - FL15413-RS Application Type Revision Code Version 2017 `r Je% � Application Status ;Approved V Comments Archived Product Manufacturer NewSouth Window Solutions Address/Phone/Emalr 4901 oak fair blvd tampa,FL 33610 (513)284-0129 danochste€n@newsouthwindow.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Address/Phone/Emall Quality Assurance Representative Address/Phone/Emali Category Windows Subcategory Mullions Compliance Method Evaluation Report from a Florida Registered Architect or.a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F Schmidt,P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ryan J.King,P.E. Validation Checklist-Hardcopy Received Certificate of Independence FL15413 R5 COI ',(a)Certificate of independence pdf Referenced Standard and Year(of Standard) Sitandard Year TAS 201,202,203 1994 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method i Option D hhps:tifloddabuilding.orgfpr/pr_app dtl.aspx7param=wGEVXQMDgtep%2bDhVRQZHLwQrlrITH41cfD76ka/o2bdEOZ3%2fR1StQ7Z3Aa/a3d%a3d 113 12126/2017 Florida Building Code Online Date Submitted 10/12/2017 Date Validated 10/12/2017 Date Pending FBC Approval 10/19/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 15413.1 a.DuraGard,Sashlite Clipped Mullion Extruded Aluminum Vertical Clipped Structural Mullion for use With Impact and non-impact window products in Masonry or Wood Openings Limits of Use Installation Instructions Approved for use in HVHZ:No FL15413 R5.Ii (b)Inst 15413.1.pdf Approved for use outside HVHZ:Yes Verified By:Lyndon R Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Patty:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15413.1 for Design Pressure Ratings, FL15413 R5 AE (b)Eval 15413,1.pdf specific use limitations,Installation instructions and product Created by Independent Third Party:Yes particulars. 15413.2! b.DuraGard,Sashlite Clipped Mullion Extruded Aluminum Vertical and Horizontal Clipped Structural Mullion for use with impact and non-impact window products In Masonry or Wood Openings Limits of Use Installation Instructions Approved for use In HVHZ:No FLI5413 R5 II (b)Inst 15413.2.pdf Approved for use outside HVHZ:Yes Verified By:Lyndon R Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other.See INST 15413.2 for Design Pressure Ratings, FLI5413, R5 AE (bl Eval 15413.2.odf specific use limitations,Installation Instructions and product Created by Independent Third Party:Yes particulars, 15413:3 c.DuraGard,Sashllte Clipped Mullion Extruded Aluminum HorizontafCI[pped Structural Mullion for use with Impact and non-impact window products in Masonry or Wood Openings Limits of Use Installation Instructions Approved for use in HVHZ:No FLI5411 R5 11 (b)Inst 15413.3.pdf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15413.3 for Design Pressure Ratings, FL15413 RS AE (b)Evai 15413.3.pdf specific use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. 15413.4 d.4100 Series Clipped Mullion 4100/4150/4160/4175 Extruded Aluminum Vertical Clipped Structural Mullion for use with impact and non-Impact window products in Masonry or Wood Openings Limits of Use Installation Instructions Approved for use in HVHZ:No FL15413 R5 II (b)Inst 154Q,4,odf Approved for use outside HVHZ:Yes Verified By:Lyndon R Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design pressure:N/A Evaluation Reports Other:See INST 15413.4 for Design Pressure Ratings, F1,15413 R5 AE (b)Evgl 15413.4.odf specific use limitations,installation instructions and product Created by Independent Third Party:,Yes particulars. 15413.5 e.'4100 Series Clipped Mullion 4106/4150/4160/4175 Extruded Aluminum Vertical and Horizontal Clipped Structural Mullion for-use with Impact and non-Impact window products in Masonry or Wood Openings Limits of Use Installation Instructions Approved for use In HVHZ:No 1`115413 R5 11 (b)lnst 15413.5.pdf Approved for use outside HVHZ:Yes Verified By:Lyndon R Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15413.5 for Design Pressure Ratings, FL15413 R5 AE (b)Evol 15413,5.pdf specific use limitations,Installation instructions and product Created by Independent Third Party:Yes particulars, 15413.6 f.4100 Series Clipped Mullion 4100/4150/4160 J 4175 Extruded Aluminum Horizontal Clipped Structural Mullion for use with Impact and non-impact window products In Masonry or Wood Openings Limits of Use Installation Instructions Approved for use in HVHZ:No I'Ll 5413 R5 II fb)Inst 15413.6.pdf Approved for use outside HVHZ:Yes Verified By:Lyndon R Schmidt,P.E.43409 https:/Moddabu€iding.orgfpripr app dtl.aspx7param--wGEVXQMDgtep°/a2bDWRQZHLwOridTH41cfD76k%2bdEOZ3%2fRlStQ7Z3A*/.3d%3d 213 12126/2017 Florida Building Code Online Impact Resistant:Yes Created by independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other.See INST 15413.6 for Design Pressure Ratings, FLI5413 R5 AF (b)EYpI 15413'&Ddf specific use limitations,Installation.Instructions and product Created by Independent Third Party:Yes particulars. 15413.7 g.4175'Serles Clipped Mullion 4175 Extrudid.Aluminuryi Vertical Clipped Structural Mullion for use'wlih Impact and non-impact Window products In ry Masonor Wood Openings, r Limits of Use Installation Instructions, Approved for use In HVHZ:YesFLI 54'f3'RS'll (b)Thst'l 54'l 3.7,r)df Approved for use outside IHIVHZd-Yes Verified BY:Lyndon F.S6hmIdt,P.E.43409 Impact fteslstanti Yes Created by Independent Third Party:Yes Design pressure;N/A Evaluaition,11teports Other:See INST I5413.7 for Design Pressure Ratings, 1`1_15413,k5 AE (b)Eval 15413.7.pdf specific Use limitations,Installation'Ins.tructloins and product Created by Independent Third Party:Yes particulars. ............. 15413.8 h.4175 Series Clipped Mullion 4175 Extruded Aluminum Vertical and Horizontal Clipped Structural Mullion for use with Impact and non-Impad window products in Masonry or Wood Openings Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL ,5413 R5 11 (bT Instt 15Q 1 ByDdf Approved for useoutside HVHZ:Yes Verified By:Lyndon E Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other,See INST 15413.8 for Design Pressure Ratings, FLI5413 R5 AE (b)Evaf 15413,8,o-df specific use limitations,Installation Instructions and product Created by Independent Third Party:Yes .particulars. 15413,9 1.4175 Series Clipped Mullion 4175 Extruded Aluminum Horizontal Clipped Structural Mullion for use with impact and non-impact window products In Masonry or Wood Openings Limits of Use Installation Instructions Approved for use In HVHZ:Yes FLI5413 R5 11 (b)Inst 15413.9,pdf Approved for use outside HVHZ-Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure.N/A Evaluation-Reports Other.See INST 15413.9 for Design Pressure Ratings, EL15413 R5 AF(bLLVAI 15413,9j)df 'specific use limitations,Installation Instructions and product Created by Independent Third Party:Yes particulars. COMM Us::2601 Blair Stone Road, The State of Florida is an AA/EEO employer.Copyright 2007-2023 State of Florida..:PrIvacyStatemen NACCeSSINItY.Statitmen :;Refyndstaternen Under Florida law,emal(addresses are public.records.If you do not want your e-mall address released In response,to a Oublic-records request,do not send electronic mail to this entity,Instead,contact the office by phone or by traditional mail.It you have any questions,please contact 850.487,1395,-Pursuant to Section 455.275(2),Florida Statutes,effective October 1.2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls provided may be used for olliciall communication with the Ilrensee.However email address"are public record,If you Eo not wish to supply a personal address,please provide the Department with an email address which can be madeavallabte to the public.To determine If you are a licensee under Chapter 45S,F.S,, please click here Product Approval Acceptss fit gm ggi ED iaol, -9 r Credit Card Safe httpi://Ooridabuilding.org/pr/piappjtl.aspx?param--wGEVXQwtDqtep�/�2bDhVRQZHLwQrlrlTH41efD76k%2bdEDZ3-kgRlStQ7Z3A�/`3d�/*3d 3/3 R W R W Building Consultants, Inc. B Consulting and Engineering Services for dw Building Industry C P.O.Boot 230 Valdm FL 33393 Phare$13A".9197 Florida Board of Professk"fattoeera Catitieft of Audwiadon No.%13 Per*trate of Independence RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company manufacturing or distributing the product or in say other entity involved in the approval process of the product named w the accompanying Florida Product Approval. Lyndon F.Schmidt,P.E. FL No.43409 October 2,2017 RAA-A Pmdnet-Job-Lab-Lb"-Pimida Product AnmvdstiFWf&Sm=W Pos ftA true HddWXCesMWc of lodepeadraoaetoa Sheet i of 1 Newsouth 4g.52 4901 OOk Fair Blvd.Tampa,FL 33610 X X. h m e:a Lj 4175 gz 9 Extruded Aluminum 4175Mu1110r; ' Vertical Clipped Structural Mullion o z� GENERAL NOTES 109.37S MAX OVERALL FRAME Wtattt R Sf MAYL RNGtE a a 1. This product has been evaluated and is in compliance with the 6th Edition(2DM Rodda UNIT WIDTH 8u8dkig.code(W stnrcturat requirements,including the"gh Velocity Hurricane Zone". }� ! 2, When used in the'HVHr,this product(d mulled together with 1WHr Impoct rated windows), complies with Section 1626 of the FBC and does not rewire an impact resistont covering. 3. Woad tucks by otters•must be anchored property to transfer toads to the structure and be x reviewed by the Building Official. 4. Separate product opprovals for each gtamtg product used with these mullions must be submiHed along with this mullion product approval.The design pressure rating of the assembly shall be the tesserof the toad capacity of the mullion as specified using tits approval or the design pressure rating of the individual glazing products used. 5. Anchoring of each gfazhg product to the mullion shall be as shown In this drawing or as shown .„ in each Individual gla product apps+ L w*Jwver B more stringent. t3 tg 6. Mullion anchor embedment to base material shall be beyond wall dressing or stucco. Cr 7. For 2t stud comtruction,an g hamirg Glaring of these units be ftte same as that shown for r s 2c buck masonry construction. & Arty cond'dions not covered in tits evaluation are subject to separate enginneering evaluation. 9. Aluminum components,including lostenets,stall meet the requirements of FBC Sectiion'2003. W 1 •, 6 = L TABLEOFCONOM 375"M , ttttttNl lDiH 6 6 6 6 6 6 na SNEErf I DFSCIUMON z X i Typical tiors 3 ger wa+notes 2 Conwonentdetails a cross seanas MULLEOWINDOWUNIIS CAM tz 3 t5 3 t es eonaeto Installation) srwc N.T.S. 1 z 4 pieSglre IatyfBs(cgluete alalion (f1vGr urdf shown malNpks alto oRowed) o■a ar JK o. 5 ilesigttGr» 7rE,fn6d03fY+WdMStowim O.Mcw-tm CFS 3 6 'Design ta"es(wood Mallotbni sheeb 3.1.6 i 1 for Design Pressure RaHngt oouwwe Na a 1 7 Artchorbracketdeto& n B o FL-15413.7 a aim 7 ori n a — tt xio�.w�..>�w�aew�ro+rv►-N.w�N...,�.o«�.u�u.�r�,c•o.r�„�w�wtwnnwo� :. N OkAr fin 4 ATa as a a►ar o 1 y Q o atxr o 0 ',,,,ittt1111 tt i tttit,'�i tM MAW rtR Wr a. — arta ttutuow ",.: 505 r 4 ►�1tt Otl�Elt101ri tNNLxNNO COIMINpwTRtt�ttN vtoks COWS=« •/ R0.1M�m vwbi%n M" wrnM tla at�lewstn O N0�1 N.M.Mv.,ow�Oown�axwrell 1�. . Qm�) v'1 t•u�a�rov�n�'Y'Y i I Oi Q ISWOWrN nw www lR7fS O mer� '� � K 00 I ,•,,, ppllll f���i, aorar+Y x Nomr,"033" • �� 71lYri�ww� • �i i1�f100Yd • r � LIO�'illlQlpO �• �Old'IM 1 �fyfflllppl�l``,� H x F - �'. !a R s s x R Isla a Z ti.. •L 461 1%;1 a sss e sasx : oes � <.: xs� : sssass � t'�-'�F:tib .}.�' 1•'�-:;f'... `c�' ::' .� ••�" j� � k•„ �.°.:�.•.. •r`- .�+ Fri ~••i�vy:N'-..• !`•.:.y.•� A 6� K1rti-[tAii'WcL�idllLM�-71�1lMlirift�NlfdMIrMW�lgt'YYMIM�MY/�MNM��IIHrD►Y am%ft 96 saw EMM&W flowvWSMLG I=w� N .or.,. wanrw n; 12 _ i 6 mopwn ago let Aqm i n ++ ww p Q '•.v :.: •� R Y Q d i 6 x R i 9 , , Q r + • F, r S R R S Y S R i Q .�::.1 r::4! �.; :}'l 3"f •.f .:~:c.b• '•fir S �! � ac V� �O fit M'Mi ll[Kf�YYR43RMtYMwwO-�arY'1 RKT 7HI�+���Y�IbY•WldJll���aO�IMMtil�MIW�A7 MImrWM�irrAWYddsl�f�i1Y1-II�WhOMin 1ltLMirlC• 11t11�if1U4LM1f� !+1 �q J °•7:4 sasasr � xaa4�' '�� asssasaa1: ssa : sssa3a ' is A.", M' .l � .. ssataaoasse �S. 8 C/ s f �.•+�w �it �—p��- �fid/10 001flII�TIMI� Ov V hupfm /IM 1 MI y 5 sunma�r�rw�uM W*slow p Owego mJ 3fMS � �� 7 t�+ac 7/'MY�4►'OCt�+r SOL/ M ~ I wo�it� ODM = 18 �wr��wawa iOMtr'�M F 1 711' * :1 x s i Rss � � ii ! = gg fa. 1 N� . N A � I .� i•!..• ...,�v;4 Vii:,: -. ....• ..:a.•J, ' .yn°i �-.�,. ..�`,aY�t't• .�.,. tiitii'�j�'Yy'�jy`�;'� �` 0 fit M'/MASR(iKN11�L+�+bi+lN�lr�O'S1Fwl�lip!{' 'MIM°�V%�NYMVMI•MIt�M�e���IMNIYA+�d�'K jy It R~A k$Mft w y s ae s �riw�"a&ABU swag now In i%WW4 Wd oo � NplNYli 43d4dfY1 t r t ~ Comm W ' � v R � zq mom Matti . 3M • V M N( ' � ►lMi•Itdit+ititpOtUSt1A��0�7�M�iM1'Uk11M�taroiW�ArtY-Mlle�lMlprM4FIMw�iMMagEh� , R1A�11YnfiwMWl�lo�1�MNMM•Ilurilw�eNMw�M1{ISWMd1C•DwN�R1►18H1�N4ffN]•lMgH . 41 PVFJ mra � � r a NLAM $ QMwfR>O17 i 3 ! MOM YUl1AR OR r PA aMIV MR ooreuJllNta A� r 3e b OJpf Af�iORIJG assm AL �`j' PhWA PAL No all {n Iln as aJ. O=1 5 R.W.DL.WSW OawILIAMM as R W R W Building Consultants, Inc. B Consulting and Engineering Services for the Building Industry C.V.Dub L7V raulL'u,rL�Dri� !'lIU"e OI�AJ7.7IYI Florida Board of Professional Engineers Certificate orAuthorizition No.9813 Date: October 12,2017 Product Category Sub Category Manufacturer Product Name NewSouth Window Solutions 4175 Windows Mullion 4901 Oak Fair Blvd Extruded Aluminum Tampa,FL 33610 Vertical Clipped Structural Mullion 813 626-6000 Scope: This is a Product Evaluation report issued by R W Building Consultants,Inc.and Lyndon F.Schmidt,P.E.(System ID# 1998)for NewSouth Window Solutions based on Rule Chapter No.61 G20�3,Method 2B of the State of Florida Product Approval,Department of Business&Professional Regulation. RW Building Consultants and Lyndon F.Schmidt,P.E:do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the Sth Edition(2017)Florida Building Code(FBC)structural requirements, Including the"High Velocity Hurricane Zone". 2. When used in the"HVHZ",this product(if mulled together with"HVHZ"impact rated windows),complies with Section 1626 of the FBC and does not require an Impact resistant covering. 3. Wood.bucks by others,must be anchored properly to transfer loads to the structure and be reviewed by the Building Official. 4. Separate product approvals for each glazing product_used with these mullions must be submitted along with this mullion product approval. The design pressure rafing of the assembly shall be the lesser of the load capacity of the mullion as specified using this approval or the design pressure rating of theindividual glazing products used. 5. Anchoring of each glazing product to the mullion shall be as shown in drawing FL-15413,7 oras shown in reach individual glazing product approval,whichever is more stringent. 6. Mullion anchor embedment to base material shall be beyond wall dressing or stucco. 7. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. B. Any conditions not covered in this evaluation are subject to separate engineering evaluation. 9. Aluminum components,including fasteners,shall meet the requirements of FBC Section 2003. 10. See drawing FL-15413.7 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test'Standard Test Laboratory. Sianed&Sealed by TEL 02031435 TAS.201,202&203-94 Testing Evaluation'Lab.,lnc. William B.Shelton,P.E. 1. Drawlna.No. Prepared by Signed&Sealed by No.FL-15413.7 RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. 2. Calculations Prepared by 6®0®B �H�gtittaIoff r®eye` Sianed&Sealed by Anc orin .Mullions lg RW Building Consultants,Inc.(CA#9813) (per FBC 1708.8 8 R609.8) RW Building Consultants,Inc.(CA#9813) `�% °G E fJ••lU? �Lyndon F.Schmidt P.E. S Lyndon F.Schmidt,P.E. � �' •w r No 43409 3. Quality Assurance it Certificate of Participation issued by National Accreditation and Management Institute,certifying that NewSouth Window Solutions is F_ STATE Ot manufacturing products withiri a quality assurance program that complies 1. 0 ; ' .,• with ISOBEC 17020 and Guide 53. 't' •FG p Q testi .'° Lyndon F.Schmidt,P.E. FL PE No.43409 1011212017 Sheet 1 of 1 12/12/2017 Florida Building Code Online "''�" ,-..,y .. t-.» s��^z-mr .: "€°"='.,k `--'°gyp- a• _ ' Utz'At xx 3 mt z r " tai+u.r•.. c+l (I ��� a #moi R FN ' +. l, SCIS Home Log In .'' User Registration I Hot Topics i Submit Surcharge ' Stats 8 Facts Publications I FBC"Staff Scis Site map• Links !•Search d. �C}11d:3 ra �f Product Approval Yet .-- USER:PublicUser Product Approval Menu>Product or AODlication Searcn>eppiicotion List>Application Detail FL �q' ,�„•�;:.p +- FL15449-R5 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer NewSouth Window Solutions Address/Phone/Email 4901 oak fair blvd tampa,FL 33610 (513)284-0129 danochstein@newsouthwindow.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Sliding Exterior Door,Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F Schmidt,P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ryan 1.King,P.E. Validation Checklist-Hardcopy Received Certificate of Independence115449 R5 COI fat Certificate of Indeoendence.odf Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA101/1:S.2/A440 2008 AAMA/W DMA/CSAI D 1/I.S.2/A440 2011 ASTM E1886 2005 ASTM E1996 2006 ASTM E1996 2009 TAS 201,202,203 1994 Equivalence of Product Standards Certified By Sections from the Code https-.//floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtep%2bDhVRQZHMIGBdzEcIXJnUTCgUQgtqlqXCN6yl6EIwa/o3da/o3d 1/3 12/12/2017 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 10/12/2017 Date Validated 10/12/2017 Date Pending FBC Approval 10/19/2017 Date Approved 12/12/2017 Suinmary of Products FL# Model,Number or Name Description 15449.1 a.6000 Series/Model 6200 Extruded Vinyl"Non-Impact"Sliding Patio Door-(XO or OX Configurations-Nominal 8'0 x 8'0) Limits of Use Installation Instructions Approved for use in HVHZ:No Ft.15449 RS Il (a)Inst 15449a odf Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other.See INST 15449.1 for Design Pressure Ratings,any FL15449 R5 AE (a)Evai 15449.1 odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15449.2 b.6000 Series/Model 6200 Extruded Vinyl"Non-Impact"Sliding Patio Door-((0 or OX Oriel Configuration-Nominal 8'0 x 8'0) Limits of Use Installation-Instructions Approved for use in HVHZ:No FL15449 R51I (a)last 154492 odf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15449.2 for Design Pressure Ratings,any 1`1.15449 R5 AE (a)Eva] 1544Q „dr additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15449.3 c.6000 Series/Model 6250 Extruded Vinyl"Impact"Sliding Patio Door-(XO or OX Configurations-Nominal 8'0 x 8'0) Limits of Use Installation Instructions Approved for use In HVHZ:No FL15449 R5 1t (a)Inst 15449.3.pdf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15449.3 for Design Pressure Ratings,any FLUA49 R5 AE (a)Eval 15449.3.odf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. 15449.4 d..6000 Series/Model 6250 Extruded Vinyl"Impact"Sliding Patio Door-(XO or OX Configurations:Nominal 870 x.8'0) Limits of Use Installation Instructions .Approved for use in HVHZ:Yes FL]5449 RS Il (a)inst45449:4,odf Approved for use outside HVHZ:'Yes VerifiedBy',Lyndon F Schmidt,P.E.43409 Impact Resistant:Yes Created by-Independent Third Party:Yes Design Pressurei N/A Evaluation Reports Other:See INST 15449.4 for Design Pressure Ratings,any FL15449 R5 AE (a!Eval 15449.4.odr additional use-limitations,installation.lnstructions.and product Created by IndependentThlyd Party:Yes particulars: 15449.5 e.6000 Series/Model 6400 Extruded Vinyl"Non-Impact"Sliding Patio Door-(OXXO Configuration-Nominal 16'0 x 8'0) Limits of Use Installation Instructions Approved for use in HVHZ:No FL15449 RS Il (a)Inst 15449.5.adf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15449.5 for Design Pressure Ratings,any 1`1.15449 R5 AE' (a)Eva615449 5.ndf additional use limitations,Installation instructions and product Created by Independent Third Party:Yes particulars. 15449.6 f.6000 Series/Model 6350 Extruded Vinyl"Im act"Slldln Patio Door- 0X0 Configuration-Nominal 9'0 x 6'8) Limits of Use 111 Installation Instructions Approved for use In HVHZ:Yes ! FL15449 R5 II (a)Inst 15449 6 odf Approved for use outside HVHZ:Yes 1 Verified By:Lyndon F.Schmidt,RE.43409 hfps://floridabUiiding.Org/pr/pr app_dti.aspx?param--wGEVXQwtDgtep%2bDhVRQZHMIGBdzEcIXJnUTCgUQgtgtqXCN6yl6Etw%3d%3d 2/3 12/12/2017 Florida Building Code Online Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15449.6 for Design Pressure Ratings,any FL15449 R5 AE (a)Eval 15449.6.adf additional use limitations,Installation Instructions and product Created by Independent Third Party:Yes particulars. 15449.7 g.6000 Series/Model 6350 Extruded Vinyl"Impact'Sliding Patio Door-(OXO Configuration-Nominal 12'0 x 8'0) Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL15449 RS 11 (a)Inst 15449.7 Ddr Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15449.7 for Design Pressure Ratings,any FLIS449 R5 AE (a)EVai 15449 7 Ddf addltfonal use limitations,Installation instructions and product Created by Independent Third Party:Yes particulars. ___.........__.__ __—_-- 15449.8 — h.5000 Series/Model 5200 Extruded Vinyl"Non-Impact"Narrow Stile Sliding Patio Door- �� (XO or OX Configurations-Nominal 6'0 z 8'0) Limits of Use Installation Instructions Approved for use In HVHZ:No FLIS449 R5 11 (a)Inst 1549:6 Ddt Approved for use outside HVHZ:Yes Verified By:Lyndon F Schmidt,A.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15449.8 for Design Pressure Ratings,any FLIS449 RS AE (a)Eval 15149.8,01' additional use limitations,Installation instructions and product Created by Independent Third Party:Yes particulars. 15449.9 I :1 5000 Series/Model 5300 Extruded Vinyl"Non Impact"Narrow Stile Sliding Patio Door- (OXO Configuration-Nominal 9'0 x 8'0) Limits of Use Installation Instructions Approved for use In HVHZ:No FLIS449 R5 11 (a)Inst 15449.9.Ddt Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party.Yes Design Pressure:N/A Evaluation Reports Other:See INST15449.9 for Design Pressure Ratings,any FLIS449 RS AE (a)Eval 15449 9 Ddf additional use limitations,Installation instructions and product Created by Independent Third Party:Yes particulars. iSa.N. rh::a Contact Us;:2601 Blair Stone Road,Tallahassee Fl.32399 Phone:850-487-1824 The State of Florida is an AA/EEO.employer.Copyright 2007.2013 State of-Florida.::Privacy Statement.;:Accessibility Statement:;Refund Statement under Florida law,email addresses are public records.If you do not want your e-mail address released In response toa public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1),Florida'Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S:must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address whlch'can be made available to the public.To determine If you are a licensee under Chapter 455,FS., please click here. Product Approval Accepts; RZ71 0-01 cera; B Credit Card Safe a a hftps://floddabuilding.org/pr/pr app_4tl.aspx?param=wGEVXQwtDgtepg/g2bDhVRQZHMIGBdzEctXJnUTCgUQgtqtqXCN6yl6EIw°/aid%3d 3/3 R W R W Building Consultants, Inc. B Consulting and Engineering Services for dee Building Industry C P.O.Banc 230 Valrico,FL 33393 Phone 811M.9197 Flmida Bond of Profeeatonal FA&W=Gef icabe of Authorization No.9813 Certificate of Independence. RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company manufaeturing or distributing the product or in any other entity involved in the approval process of the product named in the accompanying Florida Product Approval. Lyndon F.Schmidt,P.E. FL No.43409 October 2,201? RM-A Product-lob-Lob-LhWA-Florida-Product AWmjhlFlorida$canned PoninR,Wlm HowmTatifiate of tedepatdata.doc Sheet t or 1 s =�t __e ..ffiWINDOWSOLunONs 96'MAX OVERALL FRAME WIDTH39"MAX --s-a•4WIOat fds&W_Tamoa.FL33610. D.LO.WDIF1 �llI lilt V n� H " 9a0. 0 6000 Series Model 6250 Sliding Patio Door U 'IMPACT' o= o O X GENERAL NOTES 3 P fp�.1 .. ,� 1. This product has been evokroted and is in complance with the 61h Edition § & (2(117(Hodda Budding Coda(FBC(including the Wgh Velocity Htmicane Zone' & g (HVHZ(' / / a 2. Product anchors shaT be as Wed and spaced as shown an details.Anchor / embedment to base material shol be beyond wo3 dressing sling orstucco. � 3. When used in the"WHZ',this product compiies.with Section 1626 of the Hodda Bulkiing Code and does not require on impact resist ont covering. c z 4. For 2z stud framing construction,onchorfng of these units shat be the some as � Y that shown for 2x buck masonry,consiruction. G � K S. Site conditions that deviate from the detob of this drawing require further engineering analysis by a licensed engineer or registered architect. a G L W TABLE OF COMMS � MAX MAX DESIGN IRESSURE o 0 SHEEN/ DESCRIMON FRAME D.LO. WFERLOCR 167E Rst1 _p c DIMENSION DIMENSION Tr/f z u F 1 T elevations,d &general notes ►oi HEc• Dm- 6115115 g E 2 HOfiDDnt01 QOSS SBCBORS 96.a'X 96.0' 39,6T X E7.6T ALUM GI +50.0 -55.0 SME. N.T.S. 3 Verticot cross sections oda rrrr JK n 4 Buck and frcme onchonng 5 5 Bib of matglazing detog aridcomponents o.c or LFS 3 z 15449.4 0 0 vRGT 1 or d ' i i �Y •' ' �ttttbna r„ r o 1 • r _ 6 K.tB 10 N ♦ ��yµs.+ S _ •' 6 ! 4 103 �s ` ! �s*'a`w/Y J 9 � R,A.wy++.s.,awre..rwwweNN►'no�l.noausM.w+nxsaMsa�yo..++R•o�y+w}s++suo�n'sst+y3+.►3.� r � ry Y � F : M Y � f� � 1•11rw9a ~ : DAM .' a r r+ nu r r r � s O � w r • r M V 1d11ewL Bi 9AtLtYt� a�glumrur�� DOW I&any '� 3 a IwrSwfb 1�r1;lYt�rOf�os'� yr f' i`p OOr01147aWforyit lR{.� ME TO WORM w PA.r.=04 Vskin R 3i a GlObT Mover IY.t DUMMY !![ave N&9013 fDi R.Y.9YM.M C.YpafM1M Ism Rte+.wr�mw�ww�..rawwe+n�•�tw�a�o�.„assw�wrrc•a..rwutse+apos�rttuaas�.pu o 010 9 a a � r ---------�----------- -;T 7 4 -� M �M WMAX a 4" l4r5wdh �iy ��� 9 y'" WQQd VAMMmwuttnr+if4�ia� (+► 1 sa llM�f ANO IPA Mw am You%!L 33M LATE IANC►IfMIMct wmr wa 613~97 ' K 8 R R W Building Consultants, Inc. WConsulting and Engineering Services for the Building Industry B P.O.Box 230 Valrico,FL 3359$ Phone 813.659.9197 CFlorida Board of Professional Engineers Cerifficate of Authorization No.9813 Repoi-I Alm: FL-15449.4 Pi-odtict Evalitafloiz Repoa Date: Ociober 12,2017 Product Sub Category Manufacturer Product Name Category NewSouth Window Solutions 6000 Series Model 6250 Exterior Sliding Exterior- 49 1 01 Oak Fair Blvd Sliding Patio Door Doors Doors Assemblies Tampa,FL 33610. .,Impact" 1 (813)626-6000 Scope: Product Evaluation report issued by R W Building Consultants,Inc.&Lyndon F.Schmidt,P.E.(System ID#1998)for NewSouth Window Solutions,based on Rule Chapter No.61 G20-3,Method 1 D of the State of Florida Product Approval, Dept.of Business&Professional Regulation. RW-Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial Interest In the company manufacturing or distributing the product or in any other an*involved In the approval process of the product named herein. Urnliations. 1. This product has been evaluated and Is in compliance with the 6th Edition(2017)Florida Building Code(FBC)Including the"High. Velocity Hurricane Zone"(HVHZ), 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used In the"HVHZ!',this product complies with Section 1626 of the Florida Building Code and does not require and impact resistant covering. 4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-15449.4 require further engineering analysis by-a licensed engineer or registered architect 6. See drawing FL-15449.4 for size and design pressure limitations. Supporting Documents: 1, Test Report No. Test Standard Testing Laboratory Sinned b TEL 02031270 TAS 201,202,203-94 Testing Evaluation Lab.,Inc. William B,Shelton,P.E. 2. Dade County NOA Materials 16-1117.01 Butacite PV8 Interlayer'(Kuraray) 3, Drawing No. Prepared by Signed&Sealed by No.FL-15449.4 RW Building Consultants,Inc.(CA 0813) Lyndon F.Schmidt,P.E. 4. Calculations Prepared by Signed&,Sealed,by Anchoring RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. ASTM E 1300 Glass Load Lyndon F.Schmidt,P.E. 0%** SCHAf/ f*o 5. Quality Assurance Certificate of Participation issued by National Accreditation and -:f * Management Institute,certifying that NewSouth Window Solutions - : Na 43409 16. is manufacturing products within a quality assurance program that complies with ISOAEC 17020 and Guide 53. STATE 0 Lyndon F.Schmidt.P.E. e FL PE No.43409 Shoot 1 of 1 10/12/2017