FL # FL5259-R27
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer POLYGLASS USA
Address/Phone/Email 150 Lyon Drive
Fernley, NV 89408
(570)384-1230 Fxt242
jakins@polyglass.com
Authorized Signature James Akins
ja kins@polyglass, cum
Technical Representative Maury Alpert
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(912) 429-8610
MAIpert@polyglass.com
Quality Assurance Representative Ariel Lender
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954) 233-1230
ALender@polyglass.com
Category Roofing
Subcategory Underl ayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Flerida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE -59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/05/2018
Validated By John W. Knezevich, PF
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
FL 2 9 R27 COI 2017 01 COI Nieminen.odf
Standard
Year
ASTM D1970
2015
ASTM D226
2009
ASTM D6164
2011
ASTM D6222
2011
FM 4474
2011
FRSA/TRI April 2012
2012
TAS 103
1995
TAS 110
2000
https://www.floridahuiiding.org/prlpr app_4tt.aspx?param=wGEVXQwtDgvbSgAaZp3Crk... 1/3/2018
Florida Building Code Online
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval)
Date Approved
Summar of Products
UL 1897
Method 1 Option D
09/14/2017
09/15/2017
09/18/2017
12/12/2017
Page 2 of 2
2012
F L # Model, Number or
Description
Name
5259.1 Polyglass Roof
Roofing underlayments
U nd erlaymen is
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL5259 R27 I1 2n17 09 FINAL ER POLYGLASS UNDERLAYMENTS FL5259
R27.ndf
Impact Resistant: N/A
Design Pressure: +N/A/ -6225
Other: 1.) The design pressure in this
application relates to one particular
underlayment system (over concrete
Verified By: Robert Nlemmen PE -59166
Created by Independent Third Party: Yes
Evaluation Reports
FL5259 R27 AE 2017 09 FINAL ER POLYt,LA55 URfDERLAYN3ENT� FL5259
R27.0d
deck) for use under foam -on tile systems
(where the underlayment forms part of
Created by Independent Third Party: Yes
the load -path). Refer to ER Section 5.6.4
for ether systems, other deck types and
associated maximum design pressures.
2.) Refer to ER Section 5 for other limits
of use.
Sack Ne><i
C nta ;; 2Q2 131air Tallahassee Fl. 32399 Pine' 8550-487-+824
i he State of Florida is an ANEEO employer. aPYright 2007-20 f Florida. :: Priva Statement :: AccqSSiDility 5ffiCement Refund Statemenr
ilnder Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send
electronic mail to this entity. Instead, contact the office try phone or by traditional mail. If you have any questions, please contact 850.487.1355. -Pur ant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, IiCensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one.. The emaiis provided may be used for official communication with the 110en3ee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made avaitabie to the public_ To determine if you are a licensee under
Chapter 455, F.S., please dick here .
Product Approval Accepts:
Credit Card
Safe
https://www.floridabuilding.org/pr/pr_app dti-aspx?param=wGEVXQwtDgvbSgAaZp3Crk... 1/3I2018
EVALUATION REPORT
Polyglass USA, Inc.
150 Lyon Drive
Fernley, NV 98408
(570).384-1230
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
(203) 262-9245
Evaluation Report P12060.02.09-1123
FL5259-R27
Date of Issuance: 02/24/2009
Revision 23: 09/14/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 6" Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein,
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity I FRD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 14
Prepared by: `«1tis:tiute,,.
Robert J.M. Nieminen, P.E. The facsimile seal appearing was authorized by Robert Nieminen,
4
Florida Registration 1V0. 59166, Florida DCA AIVE1983j,,,,i: P.E. on 09/14/2017. This does not serve as an electronically
signed document.
CERTIFICATION OF INDEPENDENCE:
I. Trinity ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
7. Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing ,products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITYERD
ROOFING COMPONENT EVALUATION:
I. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass LISA, Inc., have demonstrated compliance with the
fallowing sections of the S'° Edition (2014) Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
PropertV
Standard
Year
1504.3.1
Wind Uplift
FM 4474
2011
1504,3.1
Wind Uplift
UL 1897
2012
1507.2.3 / 1507.1.1
Physical Properties
ASTM D226
2009
1507.2.4 / 1507.1.1, 1507.2.9.2
Physical Properties
ASTM D1970
2015
1507-3.3
Physical Properties
FRSA/TRI April 2012
2012
1507.11.2
Physical Properties
ASTM D6164
2011
1507.11.2
Physical Properties
ASTM D6222
2011
1523.6.5-2.1
Physical Properties
TAS 103
1995
TAS 110
Accelerated Weathering
TAS 110
2000
3. REFERENCES:.
f2tv
Examination
Reference
Date
FM Approvals (TST 1867)
Wind Uplift
3004091
01/12/2000
PRI (TST 5878)
Physical Properties
PR101111
04/08/2002
PRI (TST 5878)
Physical Properties
PUSA-005-02-01
01/31/2002
PRE (TST 5878)
Physical Propert4es
PUSA-013-02-01
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-02
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-03
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-018-02-01
07/14/2003
PRI (TST 5878)
Physical Properties
PUSA-028-02-01
07/13/2005
PRI (TST 5878)
Physical Properties
PUSA-033-02-01
01/12/2006
PRI (TST 5878)
Physical Properties
PUSA-035-02-01
09/29/2006
PRI (TST 5878)
Physical Properties
PUSA-055-02-02
12/10/2007
PRI (TST 5878)
Physical Properties
PUSA-061-02-02
01/28/2008
PRI (TST 5878)
Physical Properties
PUSA-076-02-01
02/22/2008
PRI (TST 5878)
Physical Properties
PUSA-083-02-01
04/14/2002
PRI (TST 5878)
Physical Properties
PUSA-088-02-01
07/29/2009
MTI (TST 2508)
Physical Properties
JX2OH7A
04/01/2008
MTI (TST 2508)
Physical Properties
RX14E8A
01/29/2009
ERD (TST 6049)
Physical Properties
11752.09.99-1
02/08/2000
ERD (TST 6049)
Wind Uplift
11757.08.01-1
08/13/2001
ERD (TST 6049)
Wind Uplift
11776.06.02
01/16/2003
ERD (TST 6049)
Physical Properties
02200-07.03
07/14/2003
ERD (TST 6049)
Wind Uplift
P1740.01.07
01/04/2007
ERD (TST 6049)
Physical Properties
P5110.04.07-1
04/11/2007
ERD (TST 6049)
Wind Uplift
P9260.03-08
03/21/2008
ERD (TST 6049)
Physical Properties
P13450.08.09
08/13/2009
ERD (TST 6049)
Wind Uplift
P30540.11.09 -R1
11/30/2009
FRD (TST 6049)
Physical Properties
P11030.11.09-1
11/30/2009
ERD (TST 6049)
Wind Uplift
P11030.11.09-2
11/30/2009
ERD (TST 6049)
Physical Properties
P11030.11.09-3
11/30/2009
ERD (TST 6049)
Physical Properties
P33360.06.10
06/25/2010
ERD (TST 6049)
Physical Properties
1?33370.03.11
03/02/2011
ERD (TST 6049)
Physical Properties
P33370.04.11
04/26/2011
ERD (TST 6049)
Physical Properties
P37300.10.11
10/19/2011
Exterior Research and Design, LLC. Evaluation Report P12060.02.09 -R23
Certificate nfAuthorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27
Pofyglass Roof Underlayments, (570) 384-1230 Revision 23: 09/14/2017
Page 2 of 14
TRINITY ER®
Entbt
Examination
Reference
Date
ERD (TST 6049)
Physical Properties
P40390.08.12-1
08/06/2012
ERD (TST 6049)
Physical Properties
P40390.08.12-2
08/07/2012
ERD (TST 6049)
Physical Properties
C41420.09.12-3
09/11/2012
ERD (TST 6049)
Wind Uplift
P39680.03.13
03/04/2013
ERD (TST 6049)
Physical Properties
P45370.04.13
04/26/2013
ERD (TST 6049)
Wind Uplift
P1738.02.07 -R2
04/29/2013
ERD (TST 6049)
Wind Uplift
11757.04.01-1-R1
04/30/2013
ERD (TST 6049)
Wind Uplift
P41630.08.13
08/06/2013
ERD (TST 6049)
Wind Uplift
P11751.05.03 -R1
11/26/2013
ERD (TST 6049)
Wind Uplift
P11781.11.03-Rl
11/26/2013
ERD (TST 6049)
Physical Properties
P45270,05.14
05/12/2014
ERD (TST 6049)
Physical Properties
6020.07.14-1
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-2
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-3
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-4
09/08/2014
ERD (TST 5049)
Physical Properties
6020.09.14-5
09/08/2014
ERD (TST 6049)
Physical Properties
5020.09.14-6
09/08/2014
ERD (TST 6049)
Physical Properties
P46520.10.14
10/03/2014
ERD (TST 6049)
Physical Properties
P44360.10.14
10/07/2014
ERD (TST 6049)
Physical Properties
P43290.10.14
10/17/2014
ERD (TST 6049)
Physical Properties
PLYG-SC7550.03.15
03/24/2015
ERD (TST 6049)
Physical Properties
P40390.04.15
04/03/2015
ERD (TST 6049)
Physical Properties
PLYG-SC8080.05.15-1
05/20/2015
ERD (TST 6049)
Wind Uplift
PLYG-SC8905.05.16-1
05/17/2016
ERD (TST 6049)
Physical Properties
PLYG-SC8080.07.16
07/16/2016
ERD (TST 6049)
Wind Uplift
PLYG-SC12025.10.16
10/12/2016
ERD (TST 6049)
Physical Properties
PLYG-SC13040.12.16
12/27/2016
ERD (TST 6049)
Physical Properties
PLYG-SC11900.03.17
03/10/2017
ERD (TST 6049)
Physical Properties
PLYG-SC12115.08.17
08/08/2017
ICC -ES (EVL 2396)
iBC Compliance
ESR -1.697
11/01/2014
Miami -Dade (CER 1592)
HVHZ Compliance
NOA 14-0717.08
01/22/2015
Polyglass USA
Manufacturing Affidavit
Products Current
02/18/2009
Polyglass USA
P/L Affidavit
Mule -Hide Cross Ltg
03/01/2008
Polyglass USA
Materials Affidavit
Polystick SA Compound
08/18/2011
UL, LLC. (QUA96251
Quality Control
Service Confirmation
Exp. 10/05/2018
4. PRODUCT DESCRIPTION:
4.1 Mechanically Fastened Underlayments:
4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet.
4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet.
4.1.3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet.
4.1.4 Polyglass APP Base is a fiberglass -reinforced, APF modified bitumen base sheet.
4.2 Self -Adhering Underlayments:
4.2,1 Polystick MTS is a nominal 60 -mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced
with polyolefinic film surface; meets TAS 103,
4.2.2 Polystick IR -Xe is a nominal 60 -mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an
aggregate surface; meets ASTM D1970.
4.2.3 Polystick TU Plus is a nominal 80 -mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a
polyester fabric surface; meets ASTM D1970 and TAS 103.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09 -R23
Certificate ofAuthonzation #9503 6" EUITiOM (2017) FRC NUN-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments; (570) 384-1230 Revision 23:09/14/2017
Page 3 of 14
TRINITY ERIC
4.2.4 Polystick TU P is a nominal 130 -mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester
reinforced, with a granular surface; meets ASTM D1970 and TAS 103.
4.2.5 Polystick TU Max is a nominal 60 -mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester
fabric surface; meets ASTM D1970 and TAS 103.
4.2.6 Polyflex SAP, Polyflex SAP FR, Mule -Hide SA -APP Cap Sheet and Mule -Hide SA -APP Cap Sheet (FR) are polyester
reinforced, APP modified bitumen cap sheets; meet FRSA/TRI April 2012.
4.2.7 Polystick Dual Pro'" is a nominal 60 --mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970.
4.2.8 Polystick Tile Pro' is a nominal 60 -mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103.
4.2.9 Polystick MU -X is a nominal 54 -mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970 (See Section
5.8).
4.3 Mechanically Fastened and/or Bonded Underlayments;
4.3.1 Elastoflex G TU is a polyester reinforced, modified bitumen tile underlayment composed of a sand -surfaced SBS
modified bitumen back -side and granule -surfaced APP modified bitumen top -side. Elastoflex G TU is for use as an
alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap Sheet" in the "Two Ply
System" from FRSA/TRJ April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems.
4.3.2 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced, 5135 modified bitumen cap sheets; meet ASTM D6164.
Elastoflex S6 G and Elastoflex S6 G FR are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380,
Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems.
Elastoflex 56 G is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI
April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex 56 G FR is for use as an
alternate to Hot Asphalt applied "Cap Sheet' in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath
mechanically fastened tile roof systems.
4.3.3 Polyflex G and Polyflex G FR are polyester reinforced, RPP modified bitumen cap sheets; meet ASTM D6222.
Polyflex G is for use as an alternate to Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012
(04-12) beneath mechanically fastened or adhered tile roof systems. Polyflex G FR is for use as an alternate to Heat
Applied "Cap Sheet" in the "Two Ply System" from FRSA/TR1 April 2012 (04-12) beneath mechanically fastened tile
roof systems.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity{ ERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
Exterior Research and Design, LLC_ Evaluation Report P12060.02.09 -R23
Certificote ofAuthorization #9503 fi " EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments; (570) 384-1230 Revision 23:09/14/2017
Page 4 of 14
l�l� i�I" ERQ
5.5 Allowable Roof Covers:
5.5.1 "Foam -On Tile" is limited to use of the following Approved the adhesives / underlayment combinations -
TABLE
1A: ALLOWABLE TILE ADHESIVE I UNDERLAYMENT COMBINA1IONS1
TABLE 1: ROOF COVER OPTIONS
Florida Product
Underlayments
i
Underlayment
Asphalt Shingles
Nail -On Tike
Foam -On Tile
Metal
Wood Shakes
&Shingles
Slate
Eiastobase
Yes
Yes
(Base Sheet in 2 -ply system)
Yes
(Base Sheet in 2 -ply system)
Yes
Yes
Yes
Elastobase P
Yes
Yes
(Base Sheet in 2 -Ply system)
Yes
(Base Sheet in 2 -ply system}
Yes
Yes
Yes
Polyglass G2 Base
No
es
(Base Sheet in 2-plY system)
(Base Sheet ine2-ply system)
NO
No
No
Polyglass APP Base
No
Yes
(Base Sheet in 2 -ply system)
Yes
(Base Sheet in 2 -ply system)
No
No
No
Polystick MTS
Yes
Yes
No
Yes
Yes
Yes
Polystick IR -Xe
Yes
No
No
No
Yes
Yes
Polystick TU P
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polystick TU Plus
Yes
Yes
Yes (See 5.5.1)
Yes
Yes
Yes
Polystick TU Max
No
Yes
Yes fSee 5.5.1)
Yes
No
No
Polystick Dual Pro
Yes
No
No
Yes
Yes
Yes
Polystick Tile Pro
Yes
Yes
Yes (See 5.5.1)
Yes
Yes
Yes
Polystick MU -X
Yes
No
No
Yes
Yes
Yes
Elastoflex S6 G
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Elastoflex S6 G FR
Yes
Yes
No
No
Yes
Yes
Elastaflex G TU
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polyflex G
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polyflex G FR
Yes
Yes
No
No
Yes
Yes
Polyflex SAP or SAP FR
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Mule -Hide SA -APP Cap Sheet
or SA -APP Cap Sheet (FR)
Yes
Yes
Yes (See 55.1)
No
Yes
Yes
5.5.1 "Foam -On Tile" is limited to use of the following Approved the adhesives / underlayment combinations -
TABLE
1A: ALLOWABLE TILE ADHESIVE I UNDERLAYMENT COMBINA1IONS1
Adhesive
Florida Product
Underlayments
Approval
DAP Foam Touch in Seal StormBond Roof
Tile Adhesive
FL14506
Polystick TU Plus, Polystick TU Max
Dow TiieBond'"
I FL22525
Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro
Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro,
ICP Adhesives Poiyset° AH -160
FL6332
Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR,
Mule -Hide SA -APP Cap Sheet or Mule -Hide SA -APP Cap Sheet (FR)
Polystick TU P, Polystick. TU Pius, Polystick TU Max, Polystick Tile Pro,
ICP Adhesives PolysetO RTA -1
FL6276
Elastoflex G TU, Elastoflex 56 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR,
Mule -Hide SA -APP Cap Sheet or Mule -Hide SA -APP Cap Sheet (FR)
Polyglass Polyl-ok Roof Tile Adhesive
FL17855
Polystick TU Plus or Polystick TU Max
S .Refer to Tile Manufacturefs or Adhesive Manufacturers Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09 -R23
Certificate ofAuthod2atlonit9503 6'' EDITION (2017) FBC NON-HVH2 EVALUATION FI.5259-1127
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 5 of 14
TR'1f ERD
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA -APP Cap Sheet or SA -APP Cap Sheet
(FR) self -adhered to:
New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing
piywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow fine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels
(designed and installed to meet wind loads for project).
Note: Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or
OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
r ASTM D41 primed structural concrete.
Polyflex G or Polyflex G FR torch -applied to:
ASTM D41 primed structural concrete.
5.6.2 Bond -to -Insulation:
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA -APP Cap Sheet or SA -APP Cap Sheet (FR) self -adhered
to:
A5TM 012$9, Type Il, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck
DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
r Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
Polyflex G or Polyflex G FR torch -applied to:
y- ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile
systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FBC Section 1504.3.1.
5.6.3 Bond to Mechanically Attached Base Lamer:
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA -APP Cap Sheet or SA -APP Cap Sheet (FR) Dual Pro or
Tile Pro self -adhered to:
> ASTM D226, Type l or IE felt; Elastobase; Elastobase P or Mule -Hide Nail Base.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
t ASTM D226, Type I or II felt; Elastobase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base.
Polyflex G or Polyflex G FR torch -applied to:
'r` Elastobase; Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Polyglass APP Base_
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum
requirements of FRSA/TRl April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in
accordance with FBC Section 1504.3.1.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09 -R23
Certificate of Autharizatian #9503 6" EDITION (2017) FBC NON-HVHZ EVALUATION FL5255-R27
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 6 of 14
TRINITY ERD
S_6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment
forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the
result of testing for wind load resistance leased on allowable wind loads, and reflects the ultimate passing pressure
divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-
12), Appendix A, Table 1A or I=BC 1609 for determination of design wind loads.
#1 Maximum Design Pressure = -90psf:
Deck: Main. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA -APP Cap Sheet and
Mule -Hide SA -APP Cap Sheet (FR), self -adhered -
#2 Maximum Design Pressure = -97.5 psf:
Deck: Min 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA -APP Cap Sheet and
Mule -Hide SA -APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
1%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12 -inch o_c.
#3 Maximum Design Pressure = -105 psi_
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction_
Primer: WB -3000
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA -APP Cap Sheet and
Mule -Hide SA -APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
1%" ring shank nails through 32 ga_, 1-5/8" diameter tin caps spaced 12 -inch o,c.
#4 Maximum Design Pressure = -1.35 sf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) PG100 or ASTM D41
Joints: Min. flinch wide strips of Elastoflex SA -V over all plywood joints.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Poiyflex SAP FR, Mule -Hide SA -APP Cap Sheet and
Mule -Hide SA -APP Cap Sheet (FR), self -adhered -
#5 Maximum Design Pressure = -315 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Polystick TU P, Polystick TO Plus, Polystick TU Max, Tile Pro, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA -APP Cap
Sheet and Mule -Hide SA -APP Cap Sheet (FR), self -adhered.
#6 Maximum Design Pressure = -622.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG 100 or ASTM D41
Underlayment; Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#7 Maximum Design Pressure =-30.0psf*:
Deck: Min. 15/32 -inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction,
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25 -inch long x 1 -inch head diameter round metal cap nails
Spacing: 6 -inch o.c. at the 3 -inch wide side laps and 6 -inch o.c. at two (2) equally spaced staggered center rows,
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA -APP Cap Sheet and
Mule -Hide SA -APP Cap Sheet (FR), self -adhered -
#8 Maximum Design Pressure = -37.5 psf*:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25 -inch long x 1 -inch head diameter round metal cap nails
Spacing: 6 -inch o.c. at the 3 -inch wide side laps and 6 -inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA -APP Cap Sheet and
Mule -Hide SA -APP Cap Sheet (FR), self -adhered.
Exterior Research and Design, LLC. Evaluation Report P12060.02_09 -R23
Certificate ofAoftrization 99503 6„ EDITION (2017) FGC NON-HVHZ EVACUATION FL5259-R27
Polyglass Roof Underlayments; (570) 384-1230 Revision 23:09/14/2017
Page 7 of 14
TRIN11YERD
##9 Maximum Design Pressure = -37.5 sf*-
fleck: Min. 19/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) or two (2) layers ASTM D226, Type II felt
Fasteners: 11 ga. x 1.25 -inch long x 1 -inch head diameter round metal cap nails
Spacing: 6 -inch o.c. at the 3 -inch wide side laps and 12 -inch o.c- at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
#10 _Maximum Design Pressure = -45 psf*:
Deck: Min. 19/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction -
Base Sheet: One (1) layer ASTM 0226, Type ll felt
Fasteners: 11 ga. x 1.25 -inch x 3/8 -inch head diameter annular ring shank roofing nails at 1 -5/8 -inch diameter tin caps
Spacing: 4 -inch o.c. at the 2 -inch wide side laps and 4 -inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA -APP Cap Sheet and
Mule -Hide SA -APP Cap Sheet (FR), self -adhered or Elastoflex G TU, applied in full mopping of hot asphalt.
#11 Maximum Design Pressure = -45 psf*:
Deck: Min. 19/32 -inch plywoodto meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Two (2) layers ASTM D226, Type 11 felt
Fasteners: 11 ga. x 1.25 -inch long x 3/8 -inch head diameter annular ring shank roofing nails at 1 -5/8 -inch diameter tin caps
Spacing. 9 -inch o.c. at the 2 -inch wide side laps and 9 -inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyfiex SAP FR, Mule -Hide SA -APP Cap Sheet and
Mule -Hide SA -APP Cap Sheet (FR), self -adhered or Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot
asphalt.
#12 Maximum Design Pressure= -45 sf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9 -inch o.c- at the 2 -inch wide side laps and 18 -inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
##13 Maximum Design Pressure= -52.5 psf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly-fi€m surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9 -inch o.c. atthe 2 -inch wide side laps and 12 -inch o.c. attwo (2) equally spaced staggered center rows.
Underlayment: E€astoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#14 Maximum Design Pressure= -52.5 psf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6 -inch o.c. at the 3 -inch wide side laps and 6 -inch o.c. at four (4) equally spaced staggered center raws-
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Poiyflex SAP, Polyffex SAP FR, Mule -Hide SA -APP Cap Sheet and
Mule -Hide SA -APP Cap Sheet (FR), self -adhered.
#15 Maximum Design Pressure = -52.5 psf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex Original Cap Fails
Spacing: 6 -inch o.c. at the 3 -inch wide side laps and 6 -inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
916 Maximum Design Pressure = -60 psf:
Deck: Min- 19/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: 11 ga- x 1 -25 -inch long x 3/8 -inch head diameter annular ring shank roofing nails at 1 -5/8 -inch diameter tin caps
Spacing: 8 -inch o.c. at the 4 -inch wide side laps and 8 -inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09 -R23
Certificate of authorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments, (570) 384-1230 Revision 23:09/1412017
Page 8 of 14
TRINITY: ERS
#17 Maximum Design Pressure = -60 psf:
Reck:
Min. 19/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners:
OMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing:
12 -inch o.c. at the 4 -inch wide side laps and 12 -inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#18 Maximum Design Pressure= -67,5 sf:
Deck:
Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underloyment)
Fasteners:
12 ga. x 1.25 -inch long x 3/8 -inch head diameter annular ring shank roofing nails at l -5/8 -inch diameter tin caps
Spacing:
8 -inch o.c. at the 4 -inch wide side laps and 8 -inch o.c. at four (4) equally spaced staggered center rows_
Underlayment:
Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -
Fasteners
applied.
#19 Maximum Design Pressure =-75 psf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underloyment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3 -inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 10 -inch o.c. atthe 4 -inch wide side laps and 10 -inch o_c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Poly -flex G, torch -
applied.
#20 Maximum Design Pressure =-90 psf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap}
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6 -inch o.c. at the 2 -inch wide side laps and 6 -inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#21 Maximum Design Pressure = -90 psf:
Deck: Min_ 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6 -inch o.c. at the 4 -inch wide side laps and 6 -inch a.c. at three [3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#22 Maximum Design Pressure = -90 psf
Deck:
Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase (sanded top surface)
Fasteners:
Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing:
6 -inch o.c. at the 4 -inch wide side laps and 6 -inch o.c. at three (3) equally spaced staggered center rows.
Underlayment:
Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
#23 Maximum Design Pressure = -90 psf:
Deck:
Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction_
Base Sheet:
Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment)
Fasteners:
Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3 -inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing:
9 -inch o.c. at the flinch wide side laps and 9 -inch o.c_ at four (4) equally spaced staggered center rows.
Underlayment:
Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or torch -applied or Polyf€ex G, torch -
applied.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09 -R23
Certificate of Authorization #9543 66r" EDMON f2017) FBC NDN-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments; (5701384-1230 Revision 23:09/14/2017
Page 9 of 14
#24 Maximum Design Pressure = -97,5 psP
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base (poly-film top surface)
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c. at the 4-inch wide side laps and 4-inch o.c, at four f4) equally spaced staggered center rows.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet (> R), self-adhered.
#25 Maximum Design Pressure =-105 sf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphait or Polyflex G, torch-applied.
#26 Maximum Design Pressure = -120 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or CMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. atfive (5) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch-applied.
#27 Maximum Design Pressure=-124psf;
Deck: Min_ 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal insulation Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-Inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
5.6.4.1 All other direct-deck, adhered Polyglass underlayment systems beneath foam-on tile systems carry a Maximum
Design Pressure of -45 psf.
5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed
that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A_
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density
designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked
with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January
2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30 -days
after installation.
Polystick IR -Xe or Polystick MU -X shall not be left exposed for longer than 90 -days after installation.
Polystick MTS, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or Elastoflex G TU shall not be left exposed for longer than
180 -days after installation.
Polyflex SAP or SAP FR, or Mule -Hide SA. APP Cap Sheet or SA -APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30
days.
Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the
prepared roof covering is to be adhesive -set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum
exposure is 180 days.
5.8 Polystick MU -X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226
roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as
set forth in Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance.
Exterior Research and Design, LLC. Fvaluation Report P12060.02.D9-R23
Certificate ofao[horizotion#9503 5'�EDITION (2017) FBC NON-HVHZ EVALUATION F15259-RZ7
Polyglass Roof Underlayments; (570) 384-1230 Revision 23:09/14/2017
Page 10 of 14
TRINITY ERD
5.9 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-1211:
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads_ Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Elastobase, Elastobase P or Mule -Hide Nail Base:
6.3.1 Non -Tile Applications:
Shall be installed in compliance with the codified requirements for ASTM D226, Type 11 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA
P FR, Mule -Hide SA -APP Cap Sheet or SA -APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or
Elastoflex 56 G FR in hot asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are
those associated with the top -layer underlayment, as set forth in Table 1.
6.3.2 Tile Applications:
Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the "Two
Ply System' from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.4 herein, coupled with
FRSA/TRI April 2012 (04-12) Installation Manual.
Exterior Research and Design, U.C. Evaluation Report P12060.02.09 -R23
Certificate ofAuth6r4ation#95D3 6" EDMON {2017) FBC NGN-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments; (570) 384-7.234 Revision 23:09114/2017
Page 11 of 14
TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum Slope
Elastoflex G TU
Flat
10 -tile stack
7:12
Lugged 8 -tile stack (6 over 2)
6:12
Elastoflex S6 G or 56 G FR
Flat or Lugged
6 -tile stack (4 over 2)
4:12
Polystick MTS
Flat or Lugged
Prohibited without battens
N/A
Polystick Tile Pro
I Flat or Lugged
6 -tile stack (4 over 2)
7:12
Polystick TU Max
Flat
6 -tile stack (4 over 2) or 10 -tile stack
7:12
Lugged 6 -tile stack (4 over 2)
7:12
Lugged 10 -tile stack
6:12
Polystick TU P
Flat
6 -tile stack (4 over 2)
6:12
Lugged 6 -tile stack (4 over 2)
4:12
Polystick TU Plus
Flat or Lugged
6 -tile stack (4 over 2)
7:12
Flat or Lugged 10 -tile stack
6:12
Polyflex G or G FR
Flat or Lugged
6 -tile stack (4 over 2)
4:12
Polyflex SA P or SA P FR
Flat or Lugged
6 -tile stack (4 over 2)
4:12
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads_ Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Elastobase, Elastobase P or Mule -Hide Nail Base:
6.3.1 Non -Tile Applications:
Shall be installed in compliance with the codified requirements for ASTM D226, Type 11 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA
P FR, Mule -Hide SA -APP Cap Sheet or SA -APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or
Elastoflex 56 G FR in hot asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are
those associated with the top -layer underlayment, as set forth in Table 1.
6.3.2 Tile Applications:
Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the "Two
Ply System' from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.4 herein, coupled with
FRSA/TRI April 2012 (04-12) Installation Manual.
Exterior Research and Design, U.C. Evaluation Report P12060.02.09 -R23
Certificate ofAuth6r4ation#95D3 6" EDMON {2017) FBC NGN-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments; (570) 384-7.234 Revision 23:09114/2017
Page 11 of 14
TRINITY
s D
6.4 Polystick MTS, IR -Xe, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or MU -X or Polyflex SAP, Polyflex SAP FR, Mule -Hide
SA -APP Cap Sheet or Mule -Hide SA -APR Cap Sheet (FR):
0.'4. _t mall De instaileo in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table 1507.1.1
for the type of prepared roof covering to be installed.
6.4.2 Direct -to -Deck with Mechanically Fastened Roof Covers:
All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA -APP
Cap Sheet or SA -APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule -
Hide Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1 -inch diameter
metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o_c. Polystick TU Pius should be back -nailed
using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane.
The head lap membrane is to cover the area being back -nailed.
All seal -lap seams (selvage laps) must be
firmly rolled with a minimum 28 lb. hand
roller to ensure full contact and adhesion.
For Dual Pro and Tile Pro, align the edge of
the top sheet to the end of the glue pattern
(the sheet will overlap the fabric).
View of Ovelap Seam of Dual Pro and Tile Pro
All over -fabric and over -granule end -laps shall have a 6 -inch wide, uniform layer of Polyplus 5o premium Modified
Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap.
Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys,
or exposed roof to wall details
Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or
Polyglass PG500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the
Polystick material of like kind, set and hand roiled in place over the repair area. Patch laps, if needed, shall be
installed in a water shedding manner.
All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 40 -Ib weighted -roller or, on steep slopes, use of a stiff broom with approximately 40 -lbs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 Ib roller) or small areas of the
roof that are not accessible to a large roller or broom -
6 -4.3 Tile Applications not allowed forPolystick Dual Pro JR -Xe orPolystick MU -X):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For mechanically fastened Tile roofing over 2 -ply system, consisting of Base Sheet and self -adhering top sheet(s), Base
Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1.
For adhesive -set tile applications, refer to Section 5.6.4 herein.
For nail -on tile systems over Polystick MTS, battens are required for loading/ staging of the tile.
6.4.4 Two 2 Ply llnderla ment Systems:
Polystick MTS followed by Polystick MTS, TU P, TU Plus, TU Max, Tale Pro, MU -X or Polyflex SAP is allowable for use
under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material.
This is not a requirement, but is allowable if a 2 -ply undedayment system is desired.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09 -R23
CertificateafAuthorizotion #9503 6'" EDITION {21317) FBG NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments; (570) 3W1230 Revision 23: 09/14/2017
Page 12 of 14
9 i MR
6.s Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR:
6.5.1 Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be installed in compliance with current Polyglass published
installation requirements. For use in tile applications:
✓ Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single
Ply System" from FRSA/TR1 April 2012 (04-12) beneath mechanically fastened the roof systems or the Hot Asphalt
applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
Elastoflex S6 G is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply
System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
Elastoflex S6 G FR is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single
Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile
roof systems.
6.5.2 For hot -asphalt -applications, Elastoflex G TU, Elastoflex 56 G or Elastoflex 56 G FR shall be fully asphalt -applied to the
substrates noted in Section 5.6. Side laps shall be minimum 3 -inch and end -laps minimum 6 -inch wide, off -set
minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt
with asphalt extending approximately 3/8 -inch beyond the lap edge.
6.6 Polyflex G or Polyflex G FR:
6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements -
For use in tile applications:
✓ Polyflex G is for use as an alternate to the Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened or adhered the roof systems (Base Sheet Limited per 5.6.3).
✓ Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI
April 2012 (04-12) beneath mechanically fastened tile roof systems (Base Sheet Limited per 5.6.3).
6.6-2 Polyflex G or Polyflex G FR shall be fully torch -applied to the substrates noted in Section 5.6. Side laps shall be
minimum 3 -inch and end -laps minimum 6 -inch wide, off -set minimum 3 feet from course to course. Side and end
laps shall be fully heat -welded and inspected to ensure minimum 3/8 -inch flow of modified compound beyond the lap
edge.
567 Tile Staging:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to
Table 2 herein, and Polyglass published requirements for tile staging.
6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used
on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or sail-
boards, to prevent tile sliding and/or damage to the underlayment during the loading process.
6.7.3 Polyglass specifies the minimum cure time after installation of self -adhering membranes and before loading of
roofing tiles is forty-eight (48) hours.
Exterior Research and Design, LLC. Evaluation Report 1`120613.02.09-1123
CertfjicateofA.uthonzatlon #9503 6' EDITION (20171 FBC NON-HVH2 EVALUATION FL5259-R27
Polyglass Roof Underlayments; (570) 3841230 Revision 23,09/14/2017
Page 13 of 14
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
S. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements. The following
plants have qualified products under their respective physical properties specifications.
Plant
Specification
Product s
Fernley, NV, Hazleton, PA & Winter Haven, FL
ASTM D1970
Poiystick MU -X
Hazleton, PA
M -D 13-0004
Elastoflex G TU
Hazleton, PA & Winter Haven, FL
ASTM D1970
Polystick IR -Xe
ASTM D1970 &TAS 103
Polystick TU Plus
ASTM D1970 & TAS 103
Polystick TU Max
Tuscaloosa, AL
ASTM D4601, Type [I
Po€yglass G2 Base
Winter Haven, FL
ASTM D226 (physicals)
Elastobase, Elastobase P
ASTM D6509
Polyglass APP Base
TA5103
Polystick MTS
ASTM D1970 & TAS 103
Polystick TU P
FRSA/TRI April 2012
Polyflex SAP, Polyflex SA P FR
ASTM D1970
Polystick Dual Pro
ASTM D1970 & TAS 103
Polystick Tile Pro
ASTM D6164
Elastoflex 56, Elastoflex 56 G FR
ASTM D6222
I Poly-Pex G, Polyflex G FR
9. QUALITY ASSURANCE ENTITY:
UL, LLC —QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09 -R23
Certilicote ofAtithorization #9503 6' EDITION (2017) FBC NOM-HVHZ. EVALUATION FL5259-R27
Polyglass Roof Underlaymentsl (570) 384-1230 Revisson 23: 09%14/2017
Page 14 of 14
Florida Building Code Online Page l of 2
Comments
Archived
Product Manufacturer POLYGLASS USA
Address/Phone/Email 150 Lyon Drive
Fernley, NV 09408
(570) 304-1230 Ext 242
jakins@polyglass.com
Authorized Signature James Akins
jakins@polyglass.com
Technical Representative Maury Aipert
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, Ft 33442
(912)429-0610
MAI pe rt@ polyglass. co m
Quality Assurance Representative Ariel Lender
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954)233-1230
ALerider@polyglass.com
Category Roofing
Subcategory Underiayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed
Robert Niernmen
the Evaluation Report
2015
Florida License
PE -59166
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
10/05/2018
Validated By
John W. Knezevich, PE
FRSA/TRI April 2012
2i Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
FL5259 R27 COI 2017 01 COI Nleminen.pdf
Standard
Year
ASTM D1970
2015
ASTM D226
2009
ASTM D6164
2011
ASTM D6222
2011
FM 4474
2011
FRSA/TRI April 2012
2012
TAS 103
1995
TAS 110
2000
https://www-floridabuilding.org/prlprr app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3Crk... 1/3/2018
Florida Building Code Online
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Sumar
my of Products
f �
UL 1897
Method 1 Option D
09/14/2017
09/15/2017
09/18/2017
12/12/2017
Mage 2 of 2
2012
FL #
Model, Number or
description
Name
5259.1
Polyglass Roof
Roofing underlayments
UndeNayments
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZf Yes
FL52S9 R27 II 2017 Q9 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
R2_ 7TDdf
Impact Resistant: NAA
Verified By: Robert Nieminen PE -59166
Design pressure: +N/A/ -622.5
Other: 1.) The design pressure in this
Created by Independent Third Party: Yes
Evaluation Reports
application relates to one particular
underlayment system (over concrete
FLS 59 R27 AE 2017 09 FINAL ER POLY SS UND RLAYMENTS FL525a-
R27.Ddf
deck) for use under foam -on the systems
(where the underlayment forms part of
Created by Independent Third Party: Yes
the load -path). Refer to ER Section 5.6.4
for other systems, other deck types and
associated maximum design pressures.
2.) Refer to ER Section 5 for other limits
of use,
Bads Next
Can - :: 2691 Blair Slone Road, Tallahassee FL 32399 Ph�_$50-487-1624
The State of Florida is an AAJEW employer. copyright 2007-2013 State of Florida :: Privacy 5 mens :: AecessihIF Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released m response to a public-remrds request, do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. if you have any questions, please contact 850.487.1395. "Pursuant to
Section 455.275(1),. Florida statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide tte Department with an email address if
they have one. The emails provided may be used hor ufPcial communication with the liconsee. However email addresses are public remrd. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under
Chapter 455, F.S., please dick here .
}
Product Approval Accepts:
k W ��_Z� E
Credit Card
Safe
https:llw-ww.floridabuilding.orglprlpr_app dtl,aspx?param=wGEVXQwtDgvbSgAaZp3Crk... 1/3/2019
. F Firm
EVALUATION REPORT
Polyglass USA, Inc.
150 Lyon Drive
Fernley, NV 98408
(570) 384-1230
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
(203) 262-9245
Evaluation Report P12060.02.09 -R23
FL5259-R27
Date of Issuance: 02/24/2009
Revision 23: 09/14/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 0 Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall he in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinityjERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 14.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DIA ANE1983ra;,;,;k
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. on 09/14/2017_ This does not serve as an electronically
signed document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity( ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned, operated or controlled by any campany manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P -E_ are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
fallowing sections of the Sth Edition (2014) Florida Building Code through testing in accordance With the fallowing Standards.
Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind Uplift
FM 4474
2011
1504.3.1
Wind Uplift
UL 1897
2012
1507.2.3 / 1507.1.1
Physicai Properties
ASTM D226
2009
1507.2.4 / 1507.1.1, 1507.2-9.2
Physical Properties
ASTM D1970
2015
1507.3.3
Physical Properties
FRSA/TRI April 2012
2012
1507.11.2
Physical Properties
ASTM D6164
2011
1507.11.2
Physical Properties
ASTM D6222
2011
1523.6.5.2.1
Physical Properties
TA5103
1995
TAS 110
Accelerated Weathering
TAS 110
2000
REFERENCES:
fnifty
Examination
Reference
Date
FM Approvals (TST 1867)
Wind Uplift
3004091
01/12/2000
PRI (TST 5878)
Physical Properties
PRI01111
04/08/2002
PRI (TST 5878)
Physical Properties
PUSA-005-02-01
01/31/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-01
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-02
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-03
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-018-02-01
07/14/2003
PRI (TST 5878)
Physical Properties
PUSA-028-02-01
07/13/2005
PRI (TST 5878)
Physical Properties
PUSA-033-02-01
01/12/2006
PRI (TST 5878)
Physical Properties
PUSA-035-02-01
09/29/2006
PRI (TST 5878)
Physical Properties
PUSA-055-02-02
12/10/2007
PRI (TST 5878)
Physical Properties
PUSA-061-02-02
01/28/2008
PRI (TST 5878)
Physical Properties
PUSA-076-02-01
02/22/2008
PRI (TST 58781
Physical Properties
PUSA-083-02-01
04/14/2008
PRI (TST 5878)
Physical Properties
PUSA-088-02-01
07/29/2009
MTI (TST 2508)
Physical Properties
JX20H7A
04/01/2008
MTI (TST 2508)
Physical Properties
RX14E8A
01/29/2009
ERD (TST 6049)
Physical Properties
11752.09.99-1
02/08/2000
ERD (TST 6049)
Wind Uplift
11757.08.01-1
08/13/2001
ERD (TST 6049)
Wind Uplift
11776.06.02
01/16/2003
ERD (TST 6049)
Physical Properties
02200.07.03
07/14/2003
ERD (TST 6049)
Wind Uplift
P1740.01.07
01/04/2007
ERD (TST 6049)
Physical Properties
P5110.04.07-1
04/11/2007
ERD (TST 6049)
Wind Uplift
P9260.03.08
03/21/2008
ERD (TST 6049)
Physical Properties
P13450.08.09
08/13/2009
ERD (TST 6049)
Wind Uplift
P30540.11.09 -R1
11/30/2009
ERD (TST 6049)
Physical Properties
P11030.11.09-1
11/30/2009
ERD (TST 6049)
Wind Uplift
P11030.11.09-2
11/30/2009
ERD (TST 6049)
Physical Properties
P11030.11.09-3
11/30/2009
ERD (TST 6049)
Physical Properties
P33360-06.10
06/25/2010
ERD (TST 6049)
Physical Properties
P33370.03.11
03/02/2011
ERD (TST 6049)
Physical Properties
P33370.04.11
044/26/2011
ERD (TST 6049)
Physical Properties
P37300.10.11
10/19/2011
Exterior Research and Design, LLC.
Evaluation Report P12060.02.09 -R23
Certificate of Authorization #9503
6" EDITION (2417) FBC NON-HVHZ
EVALUATION
FL5259-R27
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 2 of 14
inti
Examination
Reference
Date
ERD (TST 6049)
Physical Properties
P40390.08.12-1
08/06/2012
ERD (TST 6049)
Physical Properties
P40390.08.12-2
08/07/2012
ERD (TST 6049)
Physical Properties
041420.09.12-3
09/11/2012
ERD (TST 6049)
Wind Uplift
P39680.03.13
03/04/2013
ERD (TST 6049)
Physical Properties
P45370.04.13
04126/2013
ERD (TST 6049)
Wind Uplift
P1738.02.07 -R2
04/29/2013
ERD (TST 6049)
Wind Uplift
11757,04.01-1-R1
04/30/2013
ERD (TST 6049)
Wind Uplift
P41630.08.13
08/06/2013
ERD (TST 6049)
Wind Uplift
P11751.05.03 -R1
11/26/2013
ERD (TST 6049)
Wind Uplift
P11781.11.03 -R1
11/26/2013
ERD (TST 6049)
Physical Properties
P45270.05.14
05/12/2014
ERD (TST 6049)
Physical Properties
6020.07.14-1
09/08/2414
ERD (TST 6049)
Physical Properties
6020.09.14-2
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-3
09/08/2014
ERD {TST 6049)
Physical Properties
6020.09.14-4
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-5
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-6
09/08/2014
ERD (TST 6049)
Physical Properties
P46520.10.14
10/03/2014
ERD (TST 6049)
Physical Properties
P44360.10.14
14/07/2014
ERD (TST 50491
Physical Properties
P43290.10.14
10/17/2014
ERD (TST 6049)
Physical Properties
PLYG-SC7550.03.15
03/24/2015
ERD (TST 6049)
Physical Properties
P40390.04.15
04/03/2015
ERD (TST 6049)
Physical Properties
PLYG-SC8080.05.1S-1
05/20/2015
ERD (TST 6049)
Wind Uplift
PLYG-SC8905.05.16-1
05/17/2016
ERD (TST 6049)
Physical Properties
PLYG-SC8080.07.16
07/16/2016
ERD (TST 6049)
Wind Uplift
PLYG-SC12025.10.16
10/12/2016
ERD (TST 6049)
Physical Properties
PLYG-SC13040.12.16
12/27/2016
ERD (TST 6049)
Physical Properties
PLYG-SCI1900A3.17
03/10/2017
ERD (TST 6449)
Physical Properties
PLYG-SC12115.08.17
08/08/2017
ICC -ES (EVL 2396)
IBC Compliance
ESR -1697
11/01/2014
Miami -Dade (CER 1592)
HVHZ Compliance
NOA 14-0717.08
01/22/2015
Polyglass USA
Manufacturing Affidavit
Products Current
02/18/2009
Polyglass USA
P/LAffidavit
Mule -Hide Cross Ltg
03101/2008
Polyglass USA
Materials Affidavit
Polystick SA Compound
08/18/2011
UL, LLC. (QUA9625)
Quality Control
Service Confirmation
Exp_ 10/05/2018
4. PRODUCT DESCRIPTION:
4.1 Mechanically Fastened Underlayments:
4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet.
4.1.2 Elastobase P is a polyester -reinforced, S8S modified bitumen base sheet.
4.1.3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet.
4.1.4 Poiyglass APP Base is a fiberglass -reinforced, APP modified bitumen base sheet.
4.2 Self -Adhering Underlayments:
4.2.1 Polystick MTS is a nominal 60 -mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced
with polyolefinic film surface; meets TAS 103.
4.2.2 Polystick IR -Xe is a nominal 60 -mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an
aggregate surface; meets ASTM D1970.
4.2.3 Polystick TU Plus is a nominal 80 -mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a
polyester fabric surface; meets ASTIM D1970 and TAS 103.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09 -R23
Cer[.[cate of Authorizurion #9503 6" EDITION (2017) FBC NON -H VHZ EVALUATI ON FL5259-R27
Polyglass Roof Underlayments; (570} 384-1230 Revision 23: 09/14/2017
Page 3 of 14
TRINITY ERD
4.2.4 Polystick TU P is a nominal 130 -mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester
reinforced, with a granular surface; meets ASTM D1970 and TAS 103,
4.2.5 Polystick TU Max is a nominal 60 -mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester
fabric surface; meets ASTM D1970 and TAS 103.
4.2.6 Polyflex SAP, Polyflex SAP FR, Mule -Hide SA -APP Cap Sheet and Mule -Hide SA -APP Cap Sheet (FR) are polyester
reinforced, APP modified bitumen cap sheets; meet FRSA/TRI April 2012.
4.2.7 Polystick Dual Pro— is a nominal 60 -mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970.
4.2.8 Polystick Tile Pro'" is a nominal 60 -mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103.
4.2.9 Polystick MU -X is a nominal 54 -mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970 (See Section
5.8),
4.3 Mechanically Fastened and/or Bonded Underlayments:
4.3.1 Elastoflex G TU is a polyester reinforced, modified bitumen tile underlayment composed of a sand -surfaced SBS
modified bitumen back -side and granule -surfaced APP modified bitumen top -side. Elastoflex G TU is for use as an
alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened the roof systems or Hot Asphalt applied "Cap Sheet" in the "Two Ply
System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered the roof systems.
4.3.2 Elastoflex S6 G and Elastoflex 56 G FR are polyester reinforced, SBS modified bitumen cap sheets; meet ASTM D6164.
Elastoflex 56 G and Elastoflex S6 G FR are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380,
Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened the roof systems.
Elastoflex 56 G is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRl
April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex 56 G FR is for use as an
alternate to Hot Asphalt applied "Cap Sheet' in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath
mechanically fastened tile roof systems.
4.3.3 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222.
Polyflex G is for use as an alternate to Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012
(04-12) beneath mechanically fastened or adhered the roof systems. Polyflex G FR is for use as an alternate to Heat
Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRl April 2012 (04-12) beneath mechanically fastened the
roof systems.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09 -R23
Certificate afAuthorization #9503 fir' EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 4 of 14
5.5 Allowable Roof Covers:
5.5.1 "Foam -on Tile" is limited to use of the following Approved tile adhesives / underlayment combinations.
TABLE 1A: ALLOWABLE TILE ADHESIVE f UNDERLAYMENT COMBINATIONSt
Adhesive
TABLE 1: ROOF COVER OPTIONS
Underlayments
Approval
Underlayment
Asphalt Shingles
Nail -On Tile
Foam -On Tile
Metal
Wood Shakes
& Shingles
Slate
Elastobase
Yes
Yes
(Base Sheet int -ply system)
Yes
(Base Sheet in 2 -ply system)
Yes
Yes
Yes
Elastobase P
Yes
Yes
(Base Sheet in 2 -ply sysremf
Yes
(ease Sheet in 2 -ply system)
Yes
Yes
Yes
Polyglass G2 Base
No
Yes
(Base Sheet in 2 -ply system)
Yes
(Base Sheet in 2 -ply system)
No
No
No
Polygiass APP Base
No
Yes
{Base Sheet in 2 -ply system)
Yes
(Base Sheet in 2 -ply system)
No
No
No
Polystick MTS
Yes
Yes
No
Yes
Yes
Yes
Polystick IR -Xe
Yes
No
No
No
Yes
Yes
Polystick TU P
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polystick TU Plus
Yes
Yes
Yes (See 5.5.1)
Yes
Yes
Yes
Polystick TU Max
No
Yes
Yes (See 5.5.1)
Yes
No
No
Palystick Dual Pro
Yes
No
No
Yes
Yes
Yes
Polystick Tile Pro
Yes
Yes
Yes (See 55.1)
Yes
Yes
Yes
Polystick MU -X
Yes
No
No
Yes
Yes
Yes
Elastoflex S6 G
Yes
Yes
Yes (See 5.5-1)
No
Yes
Yes
Elastoflex S6 G FR
I Yes
Yes
No
No
Yes
Yes
Elastoflex G TU
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polyflex G
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polyflex G FR
Yes
Yes
No
No
Yes
Yes
Polyflex SAP or SAP FR
Yes
Yes
Yes (See 5.5-1)
No
Yes
Yes
Mule -Hide SA -APP Cap Sheet
or SA APP Cap Sheet (FR)
Yes
Yes
Yes (See 5.5-1)
No
Yes
Yes
5.5.1 "Foam -on Tile" is limited to use of the following Approved tile adhesives / underlayment combinations.
TABLE 1A: ALLOWABLE TILE ADHESIVE f UNDERLAYMENT COMBINATIONSt
Adhesive
Florida Product
Underlayments
Approval
DAP Foam Touch 'n Seai StorMBond Roof
FL14506
Polystick TU Plus, Polystick TU Max
Tile Adhesive
Dow TileSondr'
FL22525
Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro
Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro,
ICP Adhes+ves PolysetO AH -160
FL6332
Elastoflex G TU, Elastoflex 56 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR,
Mule -Hide SA -APP Cap Sheet or Mule -Hide SA -APP Cap Sheet (FR)
Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro,
ICP Adhesives Polyset® RTA -1
FL6276
Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR,
Mule -Hide SA -APP Cap Sheet or Mule -Hide SA -APP Cap Sheet (FR)
Polyglass PolyLok Roof Tile Adhesive
FL17855
Polystick TU Plus or Polystick TU Max
Refer to The Monufocture�s or Adhesive ManufoctureK5 Fiorida ProductApprovo) for Overturning Moment Resistance Performance.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1123
Certificate of Authorizo6on #9503 6"' EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Raof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 5 of 14
TRINITY ERD
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA -APP Cap Sheet or SA -APP Cap Sheet
(FR) self -adhered to:
r New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing
plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels
(designed and installed to meet wind loads for project).
Note: Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing ,plywood or
OSB sheathing should be cleaned of oil dirt and debris prior to application of Polystick membranes.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
ASTM D41 primed structural concrete.
Polyflex G or Polyflex G FR torch -applied to:
> ASTM D41 primed structural concrete.
5.6.2 Band -to -insulation:
Polystick fall variations), Polyflex SAP or SAP FR, Mule -Hide SA -APP Cap Sheet or SA -APP Cap Sheet (FR) self -adhered
to:
r ASTM 01289, Type Il, Class 1 polyisocyanurate or Type U polyisocyanurate-composite insulation; Dens Deck
DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board.
Elastoflex G TU, Elastoflex S6 G or Elastoflex 56 G FR in hot asphalt to:
r Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
Polyflex G or Polyflex G FR torch -applied to:
9 ASTM D41 primed structural concrete;. Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile
systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FBC Section 1504.3.1.
5.6.3 Bond to Mechanically Attached Base Layer:
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA -APP Cap Sheet or SA -APP Cap Sheet (FR) Dual Pro or
Tile Pro self -adhered to:
o- ASTM D226, Type I or li felt; Elastobase; Elastobase P or Mule -Hide Nail Base.
Elastoflex G TU, Elastoflex S6 G or Elastoflex 56 G FR in hot asphalt to:
'r ASTM D226, Type I or II felt; Elastobase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base.
Polyflex G or Polyflex G FR torch -applied to.
Elastobase; Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Polyglass APP Base.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in
accordance with FBC Section 1504.3.1.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09 -R23
Certificate o}Authorizaticin #9503 67' EDITION (2617) FBC NON-HVHZ EVALUATION FL5259-RZ7
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 6 of 14
TRINITY ERD
5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRl April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment
forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on file applications. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure
divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-
12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads.
#1 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Underlayment: Polystick TO P, Polystick TU Plus, Polystick TO Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA -APP Cap Sheet and
Mule -Hide SA -APP Cap Sheet (FR), self -adhered -
#2 Maximum Design Pressure = -97.5 psf:
Deck: Min. 1.5/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Polystick TO P, Polystick TO Plus, Polystick TO Max, Po[yflex SAP, Polyflex SAP FR, Mule -Hide SA -APP Cap Sheet and
Mule -Hide SA -APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
1%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12 -inch o.c.
#3 Maximum Design Pressure = -105 psf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB -3000
Underlayment: Polystick TO P, Polystick TO Plus, Polystick TO Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA -APP Cap Sheet and
Mule -Hide SA APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side taps using 12 ga. x
1%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12 -inch o.c.
#4 Maximum Design Pressure = -135 psf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) PG100 or ASTM D41
Joints: Min. 4 -inch wide strips of Elastoflex SA -V over all plywood joints.
Underlayment: Polystick TO P, Polystick TU Plus, Polystick TO Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA -APP Cap Sheet and
Mule -Hide SA -APP Cap Sheet (FR), self adhered.
#5 Maximum Design Pressure = -315 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG 100 or ASTM D41
Underlayment: Polystick TO P, Polystick TU Plus, Polystick TO Max, Tile Pro, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA -APR Cap
Sheet and Mule -Hide SA -APP Cap Sheet (FR), self -adhered.
#6 Maximum Design Pressure = -622.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer PG100 or ASTM D41
Underlayment: Elastoflex G TO or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#7 Maximum Design Pressure = -30.0_psf*:
Deck: Min. 15132 -inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25 -inch long x 1 -inch head diameter round metal cap nails
Spacing: 6 -inch o.c. at the 3 -inch wide side laps and 6 -inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polystick TO P, Polystick TO Plus, Polystick TO Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA -APP Cap Sheet and
Mule -Hide SA -APP Cap Sheet (FR), self -adhered -
#8 Maximum Design Pressure = -37.5 psf*:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25 -inch long x 1 -inch head diameter round metal cap nails
Spacing: 6 -inch o.c. at the 3 -inch wide side laps and 6 -inch o.c. at two (2) equally spaced staggered center roues.
Underlayment: Polystick TO P, Polystick TO Plus, Polystick TO Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA -APP Cap Sheet and
Mule -Hide SA -APP Cap Sheet (FR), self -adhered.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09 -R23
Certificote of Authorizotiun ifRS03 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 7 of 14
TRINITY ERD
#9 Maximum Design Pressure = -37.5psf*:
Deck: Min. 19/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) or two (2) layers ASTM D226, Type II felt
Fasteners: 11 ga. x 1.25 -inch long x 1 -inch head diameter round metal cap nails
Spacing: 6 -inch o.c. at the 3 -inch wide side laps and 12 -inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
#10 Maximum_ Design Pressure = -45 psf*:
Deck: Min. 19/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction_
Base Sheet: One (1) layer ASTM 0226, Type it felt
Fasteners: 11 ga. x 1.25 -inch x 3/8 -inch head diameter annular ring shank roofing nails at 1 -5/8 -inch diameter tin caps
Spacing: 4 -inch o.c. at the 2 -inch wide side laps and 4 -inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA -APP Cap Sheet and
Mule -Hide SA -APP Cap Sheet (FR), self-adheredor Elastoflex G TU, applied in full mopping of hot asphalt,
#11 Maximum Design Pressure= -45 osf*:
Deck: Min_ 19/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Two (2) layers ASTM D226, Type II felt
Fasteners: 11 ga. x 1 -25 -inch long x 3/8 -inch head diameter annular ring shank roofing nails at 1 -5/8 -inch diameter tin caps
Spacing: 9 -inch o.c. at the 2 -Inch wide side laps and 9 -inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA -APP Cap Sheet and
Mule -Hide 5A -APP Cap Sheet (FR), self -adhered or Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot
asphalt.
#12 Maximum Design Pressure =-45 psf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9 -inch o_c. at the 2 -inch wide side laps and 18 -inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#13 Maximum Design Pressure = -52.5 psf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9 -inch o.c. at the 2 -inch wide side laps and 12 -inch o,c_ at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#14 Maximum Design Pressure =_52.5 psf:
Deck: Min_ 15/32 -'inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6 -inch o.c. at the 3 -inch wide side laps and 6 -inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA -APP Cap Sheet and
Mule -Hide SA -APP Cap Sheet (FR), self -
adhered -#i5 Maximum Design Pressure = -52.5psf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -flim surface for torch -applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 6 -inch o.c. at the 3 -inch wide side laps and 6 -inch o,c_ at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#16 Maximum Design Pressure = -60 O:
Deck: Min_ 19/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: 11 ga_ x 1.25 -inch long x 3/8 -inch head diameter annular ring shank roofing nails at 1 -5/8 -inch diameter tin caps
Spacing: 8 -inch o.c. at the 4 -inch wide side laps and 8 -inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: 'Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09 -R23
Certificate ofauthoriaotian #3503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 8 of 14
#17 Maximum Design Pressure= -60 psf:
Deck: Min. 19/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction -
Base Sheet; Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12 -inch o.c. at the 4 -inch wide side laps and 12 -inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#18 Maximum Design Pressure=-67.5psf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment)
Fasteners: 12 ga. x 1.25 -inch long x 3/8 -inch head diameter annular ring shank roofing nails at 1 -5/8 -inch diameter tin caps
Spacing: 8 -inch o.c. at the 4 -inch wide side laps and 8 -inch a.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
#19 Maximum Design Pressure = -75 DO:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied Underlayment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3 -inch Insulation Plates or Simplex MAXX Cap
Fasteners
spacing: 10 -inch o.c. at the 4 -inch wide side laps and 10 -inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
#20 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -frim surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6 -inch o.c. at the 2 -inch wide side laps and 6 -inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#21 Maximum Design Pressure =-90psf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface far torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6 -inch o.c. at the flinch wide side laps and 5 -inch o.c. at three (3) equally spaced staggered center rows,
Underlayment Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
422 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Ease Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast 414 HD with Trufast 3" Metal Insulation Plates
Spacing: 5 -inch o.c. at the 4 -inch wide side laps and 6 -inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
423 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underloyment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with CMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3 -inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 9 -inch o.c. at the 4 -inch wide side laps and 9 -inch o.c- at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
Exterior Research and Design, LCC. Evaluation Report P12060.02.09 -R23
Certiffcote afAutharizatian 49S03 6" EDITION [20171 FBC NON-HVH2 EVALUATION FL57S9-R27
Polyglass Roof Underlayments; (570) 354-1230 Revision 23:09/1412017
Page 9 of 14
1 RIND i E ER.D
#24 Maximum Design Pressure = -97.5 Psf:
Deck: Min. 19/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25 -inch x 3/8 -inch head diameter annular ring shank roofing nails at 1 -518 -inch diameter tin caps
Spacing: 4 -inch o.c. at the 4 -inch wide side laps and 4 -inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA -APP Cap Sheet and
Mule -Hide SA -APP Cap Sheet (FR), self -adhered -
#25 Maximum Design Pressure= -105 psf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MARX Cap Fasteners
Spacing: 6 -inch o.c_ at the 2 -inch wide side laps and 6 -inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#26 Maximum Design Pressure = -120 psf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6 -inch o.c. at the 4 -inch wide side laps and 6 -inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#27 Maximum Design Pressure = -120 psf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastabase (sanded top surface)
Fasteners: Trufast #12 DP arTrufast i#14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6 -inch o.c. at the 4 -inch wide side laps and 6 -inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt.
5.6.4.1 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on tile systems carry a Maximum
Design Pressure of -45 psf.
5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed
that required under FRSA/TRi April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density
designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117_ Assemblies marked
with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January
2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30 -days
after installation.
Polystick IR -Xe or Polystick MU -X shall not be left exposed for longer than 90 -days after installation.
Polystick MTS, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or Elastoflex G TU shall not be left exposed for longer than
180 -days after installation.
Polyflex SAP or SAP FR, or Mule -Hide SA -APP Cap Sheet or SA -APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30
days.
Elastoflex 56 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the
prepared roof covering is to be adhesive -set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum
exposure is 180 days.
5.8 Polystick MU -X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226
roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as
set forth in Section 4.3, Note I. of ASTM D1970-15, should be established as to slip resistance.
Exterior Research and Design, LLC. Evaluation Report P12060.02,09 -R23
Certificate o/Authoriratioa #9503 6' EDITION (2017) FEC NON-HVHZ EVALUA T ION FL5259-R27
Polyglass Roof Underlayrnents, (570) 384-1230 Revision 23: 09/14/2017
Page 10 of 14
TRINITY iERD
5.9 Tile Slippage Limitations TAS 103 er FRSA RI A ril 2012 04-12
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Elastobase, Elastobase P or Mule -Hide Nail Base:.
6.3.1 Non -Tile Applications:
Shall be installed in compliance with the codified requirements for ASTM D226, Type Il underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA
P FR, Mule -Hide SA -APP Cap Sheet or SA -APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or
Elastoflex 56 G FR in hot asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are
those associated with the top -layer underlayment, as set forth in Table 1,
6.3.2 Tile Applications:
Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the "Two
Ply System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.4 herein, coupled with
FRSA/TRI April 2012 (04-12) Installation Manual.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09 -R23
Certificate of Aathorizotion##9503 67" £DfTION {2017) F6C NON-HVHZ EV,CLUATIO I FL5259-R27
Polyglass Roof Underlayments; (576) 384-1230 Revision 23:09/14/2017
Page 11 of 14
TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum Slope
Elastoflex G TU
Flat
10 -tile stack
7.12
Lugged
8 -tile stack (6 over 2)
6:12
Elastoflex S6 G or S6 G FR
Flat or Lugged
6 -tile stack (4 over 2)
4:12
Polystick MFS
Flat or Lugged
Prohibited without battens
N/A
Polystick Tile Pro
Flat or Lugged
6 -tile stack (4 over 2)
7:12
Flat
6 -tile stack (4 over 2) or 10 -tile stack
7:12
Polystick TU Max
Lugged
6 -tile stack (4 over 2)
7:12
Lugged
10 -tile stack
6:12
Polystick TU P
Flat
6 -tile stack (4 over 2)
6:12
Lugged
6 -tile stack (4 over 2)
4:12
Palystick TU Plus
Flat or Lugged
6 -tile stack (4 over 2)
7:12
Flat or Lugged
10 -tile stack
6:12
Polyflex G or G FR
Flat or Lugged
6 -tile stack (4 over 2)
4:12
Polyflex SA P or SA P FR
Flat or Lugged
6 -tile stack (4 over 2)
4:12
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Elastobase, Elastobase P or Mule -Hide Nail Base:.
6.3.1 Non -Tile Applications:
Shall be installed in compliance with the codified requirements for ASTM D226, Type Il underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA
P FR, Mule -Hide SA -APP Cap Sheet or SA -APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or
Elastoflex 56 G FR in hot asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are
those associated with the top -layer underlayment, as set forth in Table 1,
6.3.2 Tile Applications:
Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the "Two
Ply System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.4 herein, coupled with
FRSA/TRI April 2012 (04-12) Installation Manual.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09 -R23
Certificate of Aathorizotion##9503 67" £DfTION {2017) F6C NON-HVHZ EV,CLUATIO I FL5259-R27
Polyglass Roof Underlayments; (576) 384-1230 Revision 23:09/14/2017
Page 11 of 14
6.4
6.4.1
6.4.2
TRINITY ERD
Polystick MTS, IR -Xe, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or MU -X or Polyflex SAP, Polyflex SAP FR, Mule -Hide
SA -APP Cap Sheet or Mule -Hide SA -APP Cap Sheet (FR):
Shall be installed in compliance with the codified requirements For ASTM D1970 underlayment in FBC Table 1507.1.1
for the type of prepared roof covering to be installed.
Direct -to -Deck with Mechanically Fastened Roof Covers:
All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA -APP
Cap Sheet or SA -APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule -
Hide Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1 -inch diameter
metal disk or Simplex -type metal cap nail, at a minimum rate of 12" oec. Polystick TU Plus should be back -nailed
using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane.
The head lap membrane is to cover the area being back -mailed.
All seal -lap seams (selvage laps) must be
firmly rolled with a minimum 28 Ib. hand`
roller to ensure full contact and adhesion.
For Dual Pro and Tile Pro, align the edge of
the top sheet to the end of the glue pattern
(the sheet will overlap the fabric).
View of Ovelap Seam of Dual Pro and Tile Pro
All over -fabric and over -granule end -laps shall have a 6 -inch wide, uniform layer of Polyplus 50 Premium Modified
Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap.
Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys,
or exposed roof to wall details
Repair of Polystick membranes is to be accomplished by applying Polyplus SO Premium Modified Wet/Dry Cement or
Polyglass PG500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the
Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be
installed in a water shedding manner.
All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 40 -Ib weighted -roller or, on steep slopes, use of a stiff broom with approximately 40 -lbs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 Ib roller) or small areas of the
roof that are not accessible to a large roller or broom_
6.4.3 Tile Applications (not allowed for Polystick Dual Pro 1R -Xe or Polystick MU -X)•
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For mechanically fastened tile roofing over 2 -ply system, consisting of Base Sheet and self -adhering top sheet(s), Base
Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1.
For adhesive -set tile applications, refer to Section 5.6.4 herein.
For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile.
6.4.4 Two Z Ply Underla ment Systems:
Polystick MTS followed by Polystick MTS, TU P, TU Plus, TU Max, Tile Pro, MU -X or Polyflex SAP is allowable for use
under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material.
This is not a requirement, but is allowable if a 2 -ply underlayment system is desired.
Exterior Research and Design, LLC. Evaluation Report ?12060.02-09-R23
Certificate of Authorization #9503 6" ED[TION {2017) F8C NON-HV142 EVALUATION FL5259-R27
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 12 of 14
TRINITY LRD
6.5 Elastoflex G TU, Elastoflex 56 G or Elastoflex S6 G FR:
6.5.1 Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be installed in compliance with current Polyglass published
installation requirements. For use in tile applications:
✓ Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single
Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex 56 G is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply
System" from FRSA/TRl April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S5 G FR is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single
Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile
roof systems.
6.5.2 For hot -asphalt -applications, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be fully asphalt -applied to the
substrates noted in Section 5.6. Side laps shall be minimum 3 -inch and end -laps minimum 6 -inch wide, off -set
minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt
with asphalt extending approximately 3/8 -inch beyond the lap edge.
6.6 Polyflex G or Polyflex G FR:
6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements.
For use in the applications:
✓ Polyflex G is for use as an alternate to the Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened or adhered tile roof systems (Base Sheet Limited per 5.6,3).
✓ Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI
April 2012 (04-12) beneath mechanically fastened the roof systems (Base Sheet Limited per 5.6.3).
6.6.2 Polyflex G or Polyflex G FR shall be fully torch -applied to the substrates noted in Section 5.6. Side laps shall be
minimum 3 -inch and end -laps minimum 6 -inch wide, offset minimum 3 feet from course to course. Side and end
laps shall be fully heat -welded and inspected to ensure minimum 3/8 -inch flow of modified compound beyond the lap
edge.
6_7 Tile Staging -
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to
Table 2 herein, and Polyglass published requirements for tile staging.
6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used
on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or sail-
boards, to prevent tile s€iding and/or damage to the underlayment during the loading process.
6.7.3 Polyglass specifies the minimum cure time after installation of self -adhering membranes and before loading of
roofing tiles is forty-eight (48) hours.
Exterior Research and Design, U.C. Evaluation Report P12050.02.09 -R23
Certificate of Authorization #5503 6' EDITION (2017) FBC NON-HVH2 EVALUATION FL5259-R27
Polyglass Roof Underiayments; (570) 384-1239 Revision 23:09/14/2017
Page 13 of 14
TRINITY ERD
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS;
Contact the noted QA agency for information on product locations covered for F.A.C. 6IG20-3 QA requirements. The following
plants have qualified products under their respective physical properties sDecifications-
9
�vr-v v.i � i +'Z.sau RYilY�.0 LIY I I I I.
UL, LLC —QUA9625;; (314) 5783406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, U.C. Evaluation Report P12060 -02.09-R23
[ertifitate ofAuthorizotion #9503 67' EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayment3; (570) 384-1230 Revision 23: 09/14/2017
Page 14 of 14
Florida Building Cade Online Page 1 of 2
Technical Representative Kerri Eden
Address/Phone/Email PO Sox 1404
Joplin, MO 64802
(417) 624-6644 Ext 2305
kerri eden@tamko.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
. Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
Zachary R. Priest
the Evaluation Report
2015
Flonda License
PE -74021
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
01/07/2019
Validated By
�-- SIB I�• v m _.
SCIS Home Log in User Registration
Hot Topics Submit Surcharge Stats & Faces Publications FBC Staff 9015 Site Map Unks Search
b'
€ .a Product Approval
USER: Public User
Procto-[ Aaurova! Menu > Product er Application
Search > AooliCatim 15t r Application Detail
FL #
FL18355-R4
as
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer
TAMKO Building Products, Inc.
Address/Phone/Email
PO Box 1404
3oplin, MJ 64802
(417) 624-6644 Ext 2305
kerri—eden@tamko.com
Authorized Signature
Kerr! Eden
kerri_eden@tamko.com
Technical Representative Kerri Eden
Address/Phone/Email PO Sox 1404
Joplin, MO 64802
(417) 624-6644 Ext 2305
kerri eden@tamko.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
. Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
Zachary R. Priest
the Evaluation Report
2015
Flonda License
PE -74021
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
01/07/2019
Validated By
Locke Bowden
v Validation Checklist - Hardcopy Received
certificate of Independence
FLi 8355 RA COI TBP15001 a 2017 FBC Eval Report 5hinoles Cmal.odf
Referenced Standard and Year (of Standard) Standard
Year
ASTM D3161
2015
ASTM D 3462
2010.
ASTMD 0 7158
2011
TAS 100
1995
Equivalence of Product Standards
Certified By Approved Testing Lab
FL18355 R4 Euuiv UL letter for standards for FSC 2017.pdf
Sections from the Code
https://www.floridabuilding.orglprlpr app_dtl.aspx?parani=wGEVXQwtDquvosrHazGXQ... 1/3/2018
Florida Building Code Online
Product Approval Method Method 1 Option 1)
Date Submitted
09/25/2017
Date Validated
09/27/2017
Date Pending FBC Approval
10/08/2017
Date Approved
12/12/2017
Summary of Products
Page 2 of 2
FL # Model, Number or Name
Description
18355.1 Glass -Seal, Elite Glass -Seal,
ASTM D 3462 asphalt shingles and hip and ridge shingles
Heritage, Hentage Premium,
Heritage Vdoodgate, Heritage
Vintage, Hip and Ridge, and
Vintage Hip and Ridge Shingles
Limits of Use
Approved for use in HVHZ: Yes
Installation Instructions
FL18355 R4 II TBP15001 4 2017 FBC Eval Report Shingles
final.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest PE -74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL16355 R4 AE TBP15001.4 2017 FBC Eval Report
�hirtgles final.Ddf
Created by Independent Third Party: Yes
Contact -U5 :: 2501 8iair Stone Road Tallahassee FL 32344 Phone: 8 0-487- 8 4
Tice State of Florida is an A)VM employer. CoOvriaht 2007-2013 State of Florida. z: Privacy Statement :: n biii 5 ment :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send
electronic mail to this Vmity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to
Section 455.275(1), Florida Statutes, effeCbve 01 tuber 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address it
they have one. The emails provided may be used for official mmmunication with the 1vicensee. However email addresses are public mcord. If you do not wish to
supply a personal address, please provide the Depar#mant with an email address which can be made available to the public. To determine if you are a licensee under
Chapter 455, F.S., please Blick here .
Product Approval Accepts:
® ¢ W
Credit Card
Safe
t>tsps:llwww.flo;sidabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDquvosrHazGXQ... 1/3/2018
Certificate of Authorization No. 29824
CREEK17520 Edinburgh Dr
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813) 480-3421
EVALUATION REPORT
FLORIDA BUILDING CODE, 6""
EDITION (2417)
Manufacturer: TAMKO BUILDING PRODUCTS
issued September 25, 2017
220 West 4"Street
Joplin, MO 64801
(417) 624-6644
Manufacturing Plants: Joplin, MO
Phillipsburg, KS
Frederick, MD
Dallas, TX
Tuscaloosa, AL
Quality Assurance: UL LLC (QUA9625)
SCOPE
Category: Roofing
Subcategory: Asphalt Shingles
Code Sections: 1504.1.1, 1507.2.5, 1507.2.7.1, 1523.6.5.1
Properties: Physical properties, Wind Resistance, Wind 'Driven Rain
REFERENCES
Entity
Report No.
Standard
Year
PRI Construction Materials Technologies (TST5878)
TAP -043-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -051-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -054-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -114-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -117-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -130-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -131-02-01
TAS 100
1995
PRS Construction Materials Technologies (TST5878)
TAP -165-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -280-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -303-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -307-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -314-02-01 Rev 2
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -315-02-01
ASTM D 6381
2008(2013)e1
PRI Construction Materials Technologies (TST5878)
TAP -317-02-01
TAS 100
1995
UL LLC (TST9628)
02NK9507
ASTM D 3161
2016
UL LLC (TST9628)
04NK24266
ASTM D 3462
2010A
UL LLC (TST9628)
05NK28006
ASTM D 6381
2008(2013)e1
UL 2390
ASTM D 7158
2011
UL LLC (TST9628)
06NK03899
ASTM D 3161
2016
ASTM D 3462
2010A
UL LLC (TST9628)
08CA59132
ASTM D 3161
2016
UL LLC (TST9628)
09NK07896
ASTM D 3161
2016
ASTM D 3462
2010A
UL LLC (TST9628)
10CA50498
ASTM D 3462
2010A
UL LLC (TST9628)
I OCA64882
ASTM D 3161
2016
UL LLC (TST9628)
11NK14014
ASTM D 3161
2016
ASTM D 3462
2010A
UL LLC (TST9628)
12CA24551
ASTM{ D 3161
2016
UL LLC (TST9628)
4786110543
ASTM D 6381
2008(2013)e1
UL LLC (TST9628)
4787043752
ASTM D 3161
2016
UL LLC (TST9628)
4787148748
ASTM D 7158
2011
ASTM D 3161
2016
ASTM D 3462
2010A
CREEK Technical Services LLC (ANE11669)
TBP15001.3
Calculations
2017
TBP15001.4
FL18355-R4
Page 1 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer
shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product
attributes that are not
specifically addressed herein.
TAMKO BUILDING PRODUCTS
CREEKAsphalt Shingles
TECHid1CAL SERVICES, I...LC
PRODUCT DESCRIPTION
Elite GlassSeal@
12-114" x 36', ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3 -tab
(Frederick, Joplin &
asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa)
ceramic granules complying with ASTM D 3462.
Glass -Seal
12-114° x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3 -tab
(Frederick &
asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa)
ceramic granules complying with ASTM D 3462.
Glass -Seal
12-114" x 36", ASTM D 7158, Class H self-sealing, 3 -tab asphalt shingle with fiberglass
(Joplin)
mat coated on both sides with asphalt and surfaced with ceramic granules complying
with ASTM D 3462. Shingles shall be used in the non-HVHZ only.
Heritage©
13-114" x 39-318", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas, Frederick,
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Joplin, Phillipsburg &
complying with ASTM D 3462,
Tuscaloosa)
Heritage® Premium
13-114" x 39-338", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas, Frederick,
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Phillipsburg &
complying with ASTM D 3462.
Tuscaloosa)
Heritage® Premium
12" x 36', ASTM D 3161, Class F and ASTM D 7158, Class 'H fiberglass reinforced,
(Frederick)
laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage(H) Vintage@
17-132" x 40", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
(Phillipsburg)
laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462,
Heritage@) Woodgate
13-114" x 39-318", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas & Frederick)
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
complying with ASTM D 3462.
Heritage@ Woodgate
12" x 36-3/8", ASTM D 3161, Class F fiberglass reinforced, laminated architectural
(Frederick)
asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles
shall be used in the non-HVHZ only.
Hip and Ridge Shingles
12-114" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt
(Frederick & Joplin)
shingle surfaced with mineral granules complying with ASTM D 3462.
Vintage@ Hip and Ridge
12" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle
(Phillipsburg)
surfaced with mineral granules complying with ASTM D 3462.
TBP15001.4 FL16355-R4 Page 2 of 11
This evaluation report is provided for State of Florida product approval under Rule 61(3320-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL. SER'VICEs, LLC
INSTALLATION
Elite Glass -Seat@
(Frederick, Joplin &
Tuscaloosa)
Glass -Seal
(Frederick, Joplin (Non-
HVHZ) & Tuscaloosa)
Nailing
Area
Nailir
Area
Basic Wind Speed (Vint):
Basic Wind Speed (Vasa):
Deck (HVHZ):
Deck (Non-HVHZ):
Underlayment:
Min. slope:
Installation (HVHZ)
Installation (Nan-HVHZ):
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19132 in. plywood or wood plank for
new construction; Min. 15132 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15(32 in- plywood or wood plank for
new construction; Min. 7116 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5-118 inch exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5 -118 -inch exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern' or "6 Nail Pattern" detailed below.
NAILS
Butt Edge
Figure 1. Elite Glass -Seal & Glass -Seal
4 (Vail Pattern (Non-HVHZ only)
NAILS
------ —....... -_....... � -- _ __-_------- -------- ------- I
Butt Edge
Figure 2. Elite Glass -Seal & Glass -Seal
6 Nall Pattern
-718"
5-118"
6-718"
5-118"
TBP15001.4 FL16355-R4 Page 3 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Heritage@
(Dallas, Frederick, Joplin,
Phillipsburg & Tuscaloosa)
Heritage@ Premium
(Dallas, Frederick
Phillipsburg & Tuscaloosa)
Heritage@ Woodgate
(Dallas & Frederick)
Basic Wind Speed (Vint): Max. 194 mph
Basic Wind Speed (V.d): Max. 150 mph
TAMKO BUILDING PRODUCTS
Asphalt shingles
Deck (HVHZ):
In accordance with FBC requirements:
Solidly sheathed min. 19132 in. plywood or wood plank for
new construction; Min. 15132 in, plywood existing
construction.
Deck (Non-HVHZ):
In accordance with FBC requirements;
Solidly sheathed min. 15132 in. plywood or wood plank for
new construction; Min. 7116 in. OSB existing construction.
Underlayment:
In accordance with FBC requirements.
Min. slope:
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21.12.
Installation (HVHZ):
Installed with 5-518 in. exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installation (Nan-HVHZ)-
Installed with 5-518 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern" or `6 Nail Pattern" detailed below.
FASTENERS NAIL ZON E
COMMON
BOND
EXPOSU RE 5-518"
12-1121' --►� 12-318" 12-112"--� �--1
11
Figure 3. Heritage@, Heritage& Premium, and Heritage® Woodgate (Dallas)
4 Nail Pattern (non-HVHZ only)
C=i
NAIL ZONE
COMMON
BOND
3E 5-5/8"
1 ' i�f -�1� -112"- }� . 's"*f+- r -1 ��-► r -�t AFL ►l �-1 „
Figure 4. Heritage(D & Heritage@ Premium
6 Nail Pattern
TBP15001.4 FL18355-R4 Page 4 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which fhis report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CFE
TECHNICAL SERVICES. LLC
TAMKO BUILDING PRODUCTS
Asphalt Shingles
NAIL ZONE/
COMMON BOND
EXPOSURE 5 518"
1:L� �7-1f2 +7-11 f2'47-3/8 +-112+-112Ai
Figure 5- Heritage@ Woodgate
6 Nail Pattern
12-1/2"—
C3
2-1 2"— --r
FASTENERS
12-1/2"
`r
7
Common Bond
39-318" 1
Figure 6. Heritage®, Heritage® Premium, & Heritage® Woodgate
Alternate 6 Nail Pattern
PAINT
LINE;
7-718"
- - - - - - — - -- -- - - - ------------
INAI L ZON E
^�
EDGE OF
8-1f8"
COMMON
BOND
EXPOSURE
ACCEPTABLE
FASTENER LOCATION
DO NOT FASTEN
ALONG EDGE OF
COMMON BOND
PREFERRED
FASTENER
LOCATION
Figure 7. Heritage@ (Tuscaloosa)
Expanded Nail Zone
Nail patterns from Figures 3, 4, and 6 may be placed in the nail zone as described above
TBP15001.4 FL18355-R4 Page 5 of 11
This evatuation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES. LLC
Herne"" Premium Basic Wind Speed (Vuat):
(Frederick) Basic Wind Speed (Vasd)
Deck (HVHZ):
Deck (Non-HVHZ):
Underlayment:
Min_ slope:
Installation (HVHZ):
installation (Non-HVHZ):
HERS
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19132 in. plywood or wood plank for
new construction; Min. 15132 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15132 in. plywood or wood plank for
new construction; Min. 7116 in, OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBG requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:.12. .
Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5 in_ exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern' or `6 Nail Pattern" detailed below.
NAIL ZONE/
COMMON BOND
�EXPOSUREC
12"
Figure 8. Heritage@ Premium (Frederick)
4 Nail Pattern (non-HVHZ only)
NAIL ZONE/
FASTENERS COMMON BOND
IT
J1 2n
EXPOSURE 5°
i
Figure 9. Heritage@ Premium (Frederick)
6 Nail Pattern
TBP15001.4 FL18355-R4 Page 6 of 11
This evaluation report is provided for State of Florida product approval under Rule 61(320-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or ether product attributes that are not
specifically addressed herein.
TAfv1KC3 BUILDING PRODUCTS
CREEKAsphalt Shingles
TECHNICAL SERVICES, LLC
Heritage@ Woodgate Basic Wind Speed (Vu,): Max. 194 mph
(Frederick) Basic Wind Speed (Vasd): Max. 150 mph
Deck (Nan-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15132 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
Underlayment: In accordance with FBC requirements.
Min. slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturers application instructions when installing
shingles at slopes greater than 21:12.
Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern" or °6 Nail Pattern' detailed below.
NAIL ZONEI
COMMON BONG!
FASTENERS
-F I T
-1I " EXPOSURE Y
IL1
y2-37 Otr JET 1.1'. `1!
1 �7f� 1
Figure 10. Heritage@ Woodgate (Frederick)
4 Nail Pattern (non-HVHZ only)
MAIL ZON E1
COMMON BOND
'ASTENERS
5-112"
7EXPOSUREY
Figure 11. Heritage@ Woodgate (Frederick)
6 Nail Pattern
TBP15001.4 FL18355-R4 Page 7 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, instailation, recommended use, or other product attributes that are not
specifically addressed herein.
CREED
TECHNICAL SERVICES, LLC
Heritage@) Vintage@ Basic Wind Speed (V„it):
(Phillipsburg) Basic Wind Speed (Vaso)
Deck (HVHZ):
T
5"
Deck (Non-HVHZ)
Underlayment:
Min. slope:
installation (HVHZ):
Installation (Nan-HVHZ)
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15132 in. plywood existing
construction.
in accordance with FBC requirements.-
Solidly
equirements:Solidly sheathed min. 15132 in. plywood or wood plank for
new construction: Min. 7116 in. OSB existing construction -
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when Installing
shingles at slopes greater than 21:12.
Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either u5 Nail
Pattern" or "6 Nail Pattern" detailed below.
Figure 12. Heritage@ Vintage@
6 Nail Pattern (non-HVHZ only)
t posure
W%cn
Figure 13. Heritage@ Vintage
6 Nail Pattern
TBP15001.4 FL18355-R4 Page 8 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES.. LLC
Hip & Ridge
(Frederick & Joplin)
Basic Wind Speed (Vu,): Max. 194 mph
Basic Wind Speed (Vasa): Max. 150 mph
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Deck (HVHZ):
In accordance with FBC requirements;
Solidly sheathed min. 19132 in, plywood or wood plank for
new construction; Min. 15132 in. plywood existing
construction.
Deck (Nan-HVHZ):
In accordance with FBC requirements;
Solidly sheathed min. 15132 in. plywood or wood plank for
new construction; Min. 7/le in. OSS existing construction.
Underlayment:
In accordance with FBC requirements.
Min. slope:
2:12 and in accordance with FBC requirements.
Installation:
Installed with 5-1/8 inch exposure in accordance with the
FBC and manufacturers published installation instructions.
The direction of the exposed end shall be away from the
prevailing wind_
Direction of prevailing wind
Start 5-1/8" exposure
here—
.,
'� II
Figure 1
Fastener
r �5-5J8„
Figure 2
�} Fastener
Figure 3
1/431
Figure 14. Hip & Ridge (Frederick & Joplin)
TBP15001.4 FL18355-R4 Page 9 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TF-cHNiCAL SERVICES, LLC
Vintage0 Hip & Ridge Basic Wind Speed (VW,):
(Phillipsburg) Basic Wind Speed (Vasd):
Deck (HVHZ):
Deck (Non-HVHZ)
Underlayment:
Min. slope:
Installation:
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min_ 15/32 in. plywood existing
construction.
In accordance with FSC requirements;
Solidly sheathed min_ 15/32 in. plywood or wood plank for
new construction; Min. 7116 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements.
Installed with 5 inch exposure in accordance with the FBC
and manufacturer's published installation instructions. The
direction of the exposed end shall be away from the
prevailing wind,
Direction of prevailing wind
- ire
Figure 2
iStart
here 5" exposure
Figure 1
Fastener
�I Fastener
r `-5-1/2„
Figure 3
Figure 15. Vintage(3 Hip & Ridge (Phillipsburg)
TBP15001.4 FL18355-R4 Page 10 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services. LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
i
�, . TECHNICAL SERVICES, LL;
LIMITATIONS
TAMKO BUILDING PRODUCTS
Asphalt Shingles
1) Fire Classification is not within the scope of this evaluation.
2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ.
4) Classification to ASTM D 7158 applies to exposure B & C with a building mean roof height of 60 -ft or less.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the
deck.
7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and code compliant detail shall prevail.
8) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 6'" Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
titt,Iis11r1r1
• --2017.09.25
I
No 7402111:3
1:41
-04'00'
•�H�
-� STATE OF r'-
'0.•. • �I
R. P.E.
•.L �P.=`=�
-- �'s+ ••• R �.•' C?`.`
Zachary Priest,
Florida Registration No. 74021
//,,,ON A` ��,�'
Organization No. ANE11669
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technicat Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
TBP15001.4 FL18355-R4 Page 11 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
Florida Building Code Online
B05 Home Lay in User Registration
d �'
Product Approval
t��'��'... USER:. Public user
b'D r
Page 1 of 2
a
Hot Topics Submit Surcharge Stats & Facts Puhiimtions FBC Staff BCIS Site Map Links Search
Product AouNyal &tenv > P duct or A Ii atl n arch Aoolication List > Application Detail
FL #
FL18355-R4
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer TAMKO Building Products, Inc.
Address/Phone/Email PO Box 1404
3oplin, MO 64802
(417) 624-6644 Ext 230S
kern eden@tamko.com
Authorized Signature Kerri Eden
kerr—eden@tamko.com
Technical Representative Kerri Eden
Address/Phone/Email PO Box 1404
]oplin, MO 64802
(417) 624-6644 Ext 2305
kerri--:eden@tarnko.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
Zachary R. Priest
the Evaluation Report
2016
Florida License
PE -74021
Quality Assurance Entity
UL LLC
Quaiity Assurance Contract Expiration Date
01/07/2019
Validated By
Locke Bowden
J Validation Checklist - Hardcopy Received
Certificate of Independence
Fl 18355 R4 CCIt 7BP15001,4 2017 FB _Eval Report Shingles final. df
Referenced Standard and Year (of Standard) Standard
Year
ASTM D 3161
2016
ASTM D 3462
2010
ASTMD D 7158
2011
TAS 100
1995
Equivalence of Product Standards
Certified By Approved Testing Lab
Fl8355 R4 EQuiv UL letter for standards for FBC 2017.�df
Sections from the Code
https://www.floridabuilding.org/pr/pr_app_dtl_aspx?param= GEVXQwtDquvosrHazGXQ... 1/3/2018
Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 09/25/2017
Date Validated 09/27/2017
Date pending FBC Approval 10/08/2017
Date Approved 12/12/2017
Summary of Products
FL At Model, Number or Name Description
18355.1 Glass -Seal, Elite Glass -Seal,
Heritage, Heritage Premium,
Heritage Woodgate, Heritage
Vintage, Hip and Ridge, and
Vintage Hip and Ridge 5hingi
Page 2 of 2
ASTM D 3462 asphalt shingles and hip and ridge shingles
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FLi8355 R4 II TBP15001 4 2017 FBC Eva[ Report Shingles
Approved for use outside HVHZ: Yes final. dF
Impact Resistant: N/A Verified By: Zachary R. Priest PE -74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other: See evaluation report for limits of use. Evaluation Reports
FL18355 R4 AE TBP15001 4 2017 FBC Eval Report
Shingles dnal�dF
Created by Independent Third Party: Yes
F. —.11 Nei
Contact U5 := 26Q1 Blair ir�oad _
YalfahasseeFL 32394 Phone- 850-487-1824
The State of Florida Ls an AR/E£O employer. r ••r*ht 2007-2013 State of F!oritla.:: Privacy Statem n :: Ac ibili Sraeem nt :: Refund Statement
Under Florida law, emaa addresses are public records. if you do not want your e-mail address released in response to a public -records request, do not send
elect,,anic mai! to this entity. instead, contact the office by Phone or by traditional mail. If you have any questions, please wntact 650.487.1395. *Pursuant to
Section 455.275(1), Florida Statutes, effective Cctnber 1, 3012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one. The ernai!s provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which con be made available to the Public. To determine if you are a licensee under
Chapter 455, F.S., please dick heir _.
Product Approval Accepts:
Credit•'
Safe
security -N11 --i MCS'
https-llwww.floridabuilding.org/Pr/pr�_app__4daspx?param--wGEVXQwtDquvosrHazGXQ... 1/3/2018
Certificate of Authorization Na. 29824
CREEK17520 Edinburgh Dr
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813) 480-3421
EVALUATION REPORT
FLORIDA BUILDING CODE, 6T" E©I'noN (2017)
Manufacturer: TAMKO BUILDING PRODUCTS
Issued September 25, 2017
220 West 4" Street
Joplin, MO 64841
(417) 624-6644
Manufacturing Plants: Joplin, MO
Phillipsburg, KS
Frederick, MD
Dallas, TX
Tuscaloosa, AL
Quality Assurance: UL LLC (QUA9625)
SCOPE
Category: Roofing
Subcategory: Asphalt Shingles
Corte Sections: 1504.1.1, 1507.2.5, 1507.2.7.1, 1523.6.5.1
Properties: Physical properties, Wind Resistance, Wind Driven Rain
REFERENCES
Entity
Report No.
Standard
Year
PRI Construction Materials Technologies (TST5878)
TAP -043-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -051-02-01
TAS 100
1895
PRi Construction Materials Technologies (TST5878)
TAP -054-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -114-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -117-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -130-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -131-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -165-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -280-02 01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -303-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -307-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -314-02-01 Rev 2
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -315-02-01
ASTM D 6381
2008(2013)e1
PRI Construction Materials Technologies (TST5878)
TAP -317-02-01
TAS 100
1995
UL LLC (TST9628)
02NK9507
ASTM D 3161
2016
UL LLC (TST9628)
04NK24366
ASTM D 3462
2010A
UL LLC (TST9628)
05NK28006
ASTM D 6381
2008(2013)e1
UL 2390
ASTM D 7158
2011
UL LLC (TST9628)
06NK03898
ASTM D 3161
2016
ASTM D 3462
2010A
UL LLC (TST9628)
08CA59132
ASTM D 3161
2016
UL LLC (TST9628)
09NK07896
ASTM D 3161
2016
ASTM D 3462
2010A
UL LLC (TST9628)
1 OCA50498
ASTM D 3462
2010A
UL LLC (TST9628)
10CA64882
ASTM D 3161
2016
UL LLC (TST9628)
11NK14014
ASTM D 3161
2016
ASTM D 3462
2010A
UL LLC (TST9628)
12CA24551
ASTM D 3161
2016
UL LLC (TST9628)
4786110543
ASTM D 6381
2008(2013)e1
UL LLC (TST9628)
4787043752
ASTM D 3161
2016
UL LLC (TST9628)
4787148748
ASTM D 7158
2011
ASTM D 3161
2016
ASTM D 3462
2010A
CREEK Technical Services LLC (ANE11669)
TBP15001.3
Calculations
2017
TBP15001.4
FL18355-R4
Pagel of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
TAMKO BUILDING PRODUCTS
CREEKAsphalt Shingles
T'ECHNiCAL SERVICES, LLC
PRODUCT DESCRIPTION
Elite GlassSeaW
12-114" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3 -tab
(Frederick, Joplin &
asphalt shingle with Fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa)
ceramic granules complying with ASTM D 3462.
Glass -Seal
12-114" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3 -tab
(Frederick &
asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa)
ceramic granules complying with ASTM D 3462.
Glass -Seal
12-114" x 36", ASTM D 7158, Class H self-sealing, 3 -tab asphalt shingie with fiberglass
(Joplin)
mat coated on both sides with asphalt and surfaced with ceramic granules complying
with ASTM D 3462. Shingles shall be used in the non-HVHZ only.
Heritage®
13-114` x 39-318", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas, Frederick,
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Joplin, Pblilipsburg &
complying with ASTM D 3462.
Tuscaloosa)
Heritage® Premium
13-1/4" x 39-318", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas, Frederick,
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Phillipsburg &
complying with ASTM D 3462.
Tuscaloosa)
Heritage® Premium
12" x 36°, ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
(Frederick)
laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage® Vintage®
17-112." x 40", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
(Phillipsburg)
laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage® Woodgate
13-114" x 39-318", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas & Frederick)
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
complying with ASTM D 3462.
Heritage® Woodgate
12" x 36-318", ASTM D 3161, Class F fiberglass reinforced, laminated architectural
(Frederick)
asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles
shall be used in the non-HVHZ only.
Hip and Ridge Shingles
12-114" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt
(Frederick & Joplin)
shingle surfaced with mineral granules complying with ASTM D 3462.
Vintage@ Hip and Ridge
12" x 12n, ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle
(Phillipsburg)
surfaced with mineral granules complying with ASTM D 3462.
TBP15001.4 FL18355-R4 Page 2 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
t
CREEK
TECHNICAL SiERvicES, LLC
INSTALLATION
Elite Glass -Seale
Basic Wind Speed (V,,,t):
(Frederick, Joplin &
Basic Wind Speed (VaA):
Tuscaloosa)
Deck (HVHZ):
Glass -Seal
(Frederick, Joplin (Nan-
HVHZ) & Tuscaloosa)
Deck (Non-HVHZ):
Underlayment:
Min. slope:
Installation (HVHZ):
Installation (Non-HVHZ)
Nailing
Area
Nailing
Area
TAMtKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBG requirements;
Solidly sheathed min. 19132 in. plywood or wood plank for
new construction; Min. 15132 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15132 in. plywood or wood plank for
new construction; Min_ 7116 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5-118 inch exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5 -118 -Inch exposure in accordance with FBC
requirements and manufacturer's published installation
instructions_ Shingles shall be attached using either "4 Nail
Pattern or "6 Nail Pattern" detailed below.
NAILS
Butt Edge
Figure 1. Elite Glass -Seal & Glass -Seal
4 Nail Pattern (Nan-HVHZ only)
II`>r:1L�
718"
5-118"
Butt Edge
Figure 2. Elite Glass -Seal & Glass -Seal
6 Nail Pattern
-7/8u
5-118"
TBP15001.4 FL18355-R4 Page 3 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein_
TAMKO BUILDING PRODUCTS
CREEKAsphalt Shingles
TECHNICAL SERVICES. LLC
Heritage@
Basic Wind Speed (Vitt):
Max. 194 mph
(Dallas, Frederick, Joplin,
Basic Wind Speed (Vasa):
Max. 150 mph
Phillipsburg & Tuscaloosa)
Deck (HVHZ):
In accordance with FBC requirements;
&
Solidly sheathed min. 19/32 in. plywood or wood plank for
Heritage® Premium
new construction; Min. 15132 in. plywood existing
(Dallas, Frederick
construction_
Phillipsburg & Tuscaloosa)
Deck (Nan-HVHZ):
In accordance with FBC requirements;
&
Solidly sheathed min. 15/32 in. plywood or wood plank for
Heritage@ Woodgate
new construction; Min. 7116 in. OSB existing construction.
(DWas & Frederick)
Underlayment:
In accordance with FBC requirements.
Min. slope:
2.12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installation (HVHZ):
Instatled with 5-518 in. exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installation (Non-HVHZ)
Installed with 5-5/8 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern" or `6 Nail Pattem" detailed below.
6-11811
FASTENERSj::,:,,,�NAIL ZONE
GOMMON
BOND
EXPOSURE 5-6/8"
12-112"- 12-3/8" 12-112'
Figure 3. Heritage@, Heritage@ Premium, and Heritage@ Woodgate (Dallas)
4 Nail Pattern (non-HVHZ only)
LA
NAIL ZONE
COMMON
BOND
IE 5-8,8"
Figure 4. Heritage@ & Heritage@ Premium
6 Nail Pattern
TBP15001.4 FL18355-R4 Page 4 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES. LLC
TAMKO BUILDING PRODUCTS
Asphalt Shingles
NAIL ZONE/
COMMON BOND
6.118"
1 " �7-Y12+7-1
�T
EXPOSURE 5 518"
—J ±
!2' 47-318 +7 -1 I2 +7 -1 l2 &�
Figure 5. Heritage@ Woodgate
6 Nail Pattern
D. Common Bond
0
Figure 6. Heritage@, Heritage@ Premium, &. Heritage@ Woodgate
Alternate 6 Nail Pattern
PAI NT
LINE, -,'k
7-718" _---- NAIL ZONE
---------------------- -- moi►_
EDGE OF
6-118'" COMMON
BOND
EXPOSURE
5-5/811
ACCEPTABLE
FASTENER LOCATION
DO NOT FASTEN
ALONG EDGE OF
-------____-- _ COMMON BOND
PREFERRED
FASTENER
LOCATION
Figure 7. Heritage® (Tuscaloosa)
Expanded Nail Zone
Nail patterns from Figures 3, 4, and 6 may be placed in the nail zonae as described above
T$P15001.4 FL18355-R4 Page 5 of 11
This evaluation report is provided for State of Florida product approval under Rule 61620-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
speciica$ly addressed herein.
REEK
TECHNICAL SERVICES. l—I_C
heritage@ Premium Basic Wind Speed (VtX
(Frederick) Basic Wind Speed (Vard):
Deck (HVHZ):
Deck (Non-HVHZ):
Underlayment:
Min. slope:
Installation (HVHZ):
Installation (Non-HVHZ):
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
in accordance with FBC requirements;
Solidly sheathed min. 19132 in. plywood or wood plank for
new construction, Min. 15132 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15132 in. plywood or wood plank for
new construction; Min. 7116 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FSC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12. .
Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern' detailed
below
Installed with 5 in. exposure in accordance with FBC
requirements and manufacturers published installation
instructions. Shingles shall be attached using either °4 Nail
Pattern" or "6 Nail Pattern" detailed below.
NAIL ZONEJ
SrL /COMMON BOND
51/211 Q(POSURE "
12"--l.�a--11 "�--i
Figure 8. Heritage® Premium (Frederick)
4 Nail Pattern (non-HVHZ only)
NAIL ZONEf
FASTENERS COMNMON BOND
5112,
E
SURE 5"
g„--*�Sr, 9112" 14-1
Figure 9. Heritage® Premium (Frederick)
6 Nail Pattern
TBP15001.4 FL18355-R4 Page 6 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
REEK
TECHNICAL. SERVICES, LLC
Heritage® Woodgate
(Frederick)
Basic Wind Speed (Vu,t):
Basic Wind Speed (Vasd):
Deck (Non-HVHZ):
Underlayment:
Min. slope:
Installation (Non-HVHZ):
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max_ 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 15132 in. plywood or wood plank for
new construction; Min. 7116 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5 in. exposure in accordance with FBC
requirements and manufacturers published installation
instructions_ Shingles shall be attached using either °4 Nail
Pattern" or "6 Nail Pattern" detailed below.
AIL ZONE1
OMMON BOND
5-1f2"
FASTENERS
v- IT
EXPOSURE V'
1
1} 1r 12-3/8"— 11" -- k–r
Figure 16. Heritage® Wood gate (Frederick)
4 Nail Pattern (non-HVHZ only)
NAIL ZON E1
COMMON BONG
FASTENERS
WTT
5•it2" EItPOSUFtE 5"
1"--1, �- 9-112" ' 9 18 3 9-112" —� i0l-1
Figure 11. Heritage® Woodgate (Frederick)
6 Nail Pattern
TBP15001.4 FL18355-R4 Page 7 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shat) notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
s_
CREEK
TECHNICAL SERVICES, LLC
Heritage® Vintage@ Basic Wind Speed (Veit):
(Phillipsburg) Basic Wind Speed (Va,,d):
Deck (HVHZ):
Deck (Non-HVHZ)
Underlayment:
Min. slope:
installation (HVHZ)
Installation (Non-HVHZ):
Fwtengs
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBG requirements;
Solidly sheathed min. 19132 in. plywood or wood plank for
new construction; Min. 15132 in. plywood existing
construction.
in accordance with FSC requirements;
Solidly sheathed ruin. 15132 in. plywood or wood plank for
new construction, Min. 7116 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail 'Pattern" detailed
below.
Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "5 Nail
Pattern" or'6 Nail Pattern" detailed below.
17-112"
1_1"W�
_17 i
Figure 12, Heritage& Vintage®
5 Nail Pattern (non-HVHZ only)
FXM,UK
11b%h
Figure 13. Heritage@ Vintage°
6 Nail Pattern
TBP15001 A FL18355-R4 Page 8 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
11��� �� TAMK� BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES. LLC
Hip & Ridge Basic Wind Speed (Vua): Max. 194 mph
(Frederick & Joplin) Basic Wind Speed (V w): Max_ 150 mph
Deck (HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19132 in. plywood or wood plank for
new construction: Min. 15132 in. plywood existing
construction.
Deck (Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min_ 15132 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
Underlayment: In accordance with FBC requirements.
Min. slope: 2:12 and in accordance with FBC requirements.
Instailation: Installed with 5-118 inch exposure in accordance with the
FBC and manufacturer's published installation instructions.
The direction of the exposed end shall be away from the
prevailing wind.
Direction of prevailing wind
Mart 5-118" exposure
here--
MX\
Figure 1
1 „
Fastener
Figure 2
:,- r.W axposure
1"
Fastener
Figure 3
114"
Figure 14. Hip & Ridge (Frederick & Joplin)
TBP15001.4 FL18355-R4 Page 9 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-1 The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specificaily addressed herein.
"CR
EEK
TECHNICAL SERVICEs, LLC
VintageQ Hip & Ridge Basic Wind Speed (Vit):
(Phillipsburg) Basic Wind Speed (V11d):
Deck (HVHZ):
Deck (Non-HVHZ):
Underlayment:
Min. slope:
Installation:
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15132 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15132 in. plywood or wood plank for
new construction; Min_ 7115 in. OSB existing construction.
In accordance with FSC requirements.
2:12 and in accordance with FBC requirements.
Installed with 5 inch exposure in accordance with the FBC
and manufacturers published installation instructions. The
direction of the exposed end shall be away from the
prevailing wind.
Direction of prevailing wind
Figure
1„
- Fastener
Figure 2
t
f , O y
i���rntf
�f
`its; 1„
�i Fastener
Figure 3
Figure 15. Vintage0 Nip & Ridge (Phillipsburg)
TBP15001.4 FL18355-R4 Page 10 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor impiy warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
LIMITATIONS
TAMKO BUILDING PRODUCTS
Asphalt Shingles
1) Fire Classification is not within the scope of this evaluation.
2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ.
4) Classification to ASTM D 7158 applies to exposure B & C with a building mean roof height of 60 -ft or less.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris, All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the
deck.
7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and code compliant detail shall prevail.
8) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, e Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
rtrrrrrrr
*,iyti�rrrR.
PRS''-.
2017.09.25
.``1,G�RG E N•
No 74021 =-11.31:41
-04'00
t� STATE OF
•�� '
R. Priest, P.E.
✓'O0 R
Zachary
Florida Registration No. 74021
rrrr, ON P
Organization No. ANE11669
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
TBP15001.4 FL18355-R4 Page 11 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.