HomeMy WebLinkAboutProduct Approval i
I
ROOFING ASSEMBLY APPROVAL
Category Roofing
Sub-Category: Asphalt Shingles
Materials: Laminate
Deck Type: Wood j
i
i
SCOPE I
This approves TAMKO's Heritage,Heritage Woodgate and Heritage Premium asphalt shingles,manufactured by
TAMKO Building Products,Inc.,as described in this Notice of Acceptance and designed to comply with the Florida
Building Code High Velocity Hurricane Zones.
PRODUCT DESCRIPTION
Product Dimensions Test Product Description
Specifications ,i
i
iHeritage 13 '/a"x 39'/8" TAS 110 Dimensional asphalt shingle.
Manufacturing Location #1, 2, 3
Heritage Woodgate 131/4"x 39 3/8" TAS 110 Dimensional asphalt shingle.
Manufacturing Location #1,3
Heritage Premium 131/4"x 39'/8" TAS 110 Dimensional asphalt shingle.
,:Manufacturing Location #1, 2, 3
MANUFACTURING LOCATIONS
1. Dallas,TX
2. Tuscaloosa,AL
3. Frederick,MD '
EVIDENCE SUBMITTED
Test Agency Test Identifier { Test Name/Report Date
Underwriters Laboratories,Inc. TAS 107&UL 790 04CA44252 02/25/05
ASTM D3462 02NK33813 09/23/02
ASTM D 3462&TAS 107 R2919 Letter 03/10/11
i' ASTM D3462 l; 4789110543 08/26/14
TAS 107 I" 1 02/19/15
ASTM E 108 08/26/14
ASTM D3161,Class F 4787043752 10/20/15
PRI Asphalt Technologies,Inc. TAS 100 TAP-129-02-01 05/26/05
TAS 100 TAP430-02-01 05/26/05
TAS 100 TAP-131-02-01 05/26/05
I 1
! PRI Construction Materials Technologies LLC TAS 100 TAP-303-02-01 12/12/14
�! TAS 100 ;' TAP-307-02-01 02/10/15
TAS 100 TAP-317-02-01 09/02/15
NOA No.:15-1215.10
MIAMI•DADB COUNTY i Expiration Date: 12/01/20
Approval Date: 05/26/16
Page 2 of 6
{ I I
LINIITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
{ 2. Shingles shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule.61 G20-3 of the Florida Administrative Code.
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115.
3. The manufacturer shall provide clearly written application instructions.I�
4. Exposure and course layout shall be in compliance with Detail`A';jattached.
5. Nailing shall be in compliance with Details W,attached. 3 i
LABELING
Shingles shall be permanently labeled with the manufacturer's name and/or logo, city and state of
manufacturing facility, and the following statement: "Miami-Dade County Product Control Approved"or with
the Miami-Dade County Product Control Seal as seen below: 1
i
MIAMI-DADE COUNTY
BUILDING PERMIT REQUIREMENTS
As required by the Building Official or the applicable Building Code in;order to properly evaluate the
installation of this system. This Notice of Acceptance on its own cannot be used to obtain a building permit.
i
I �
i�
I
I
i
A
I
i
i�
NOA No.:15-1215.10
MIAMI-DADE COUNTY i Expiration Date: 12/01/20
Is i Approval Date: 05/26/16
Page 3 of 6
I
I
DETAIL A !
I
HERITAGE,HERITAGE WOODGATE,AND HERITAGE PREMIUM
Ali dimensions are in inches.
5TH COURSE
4TH COURSE I'
i
1o3^
i
3RD COURSE I
2ND COURSE
23
11ST COURSE
29 I
i
Full
I I
DETAIL S
I ,
I
HERITAGE SHINGLE I I
FIG. I FASTENING PATTERN
I
� I
All dimensions are in inches
39-3/8"
1" 7%" 7 W 7 3/s" 7'/" 7%" 1" 13-1/4"aI�I�I�I��H
I.
__ _____________ ___.____:.______:::::__--:__________:_- ______-�•-____: ___
&1/8"
!' 5-5/8"
Exposure
i
I
I
NOA No.: 15-1215.10
MIAMbDADE CouNTY Expiration Date: 12/01/20
Approval Date: 05/26/16
f Page 4 of 6
' I'
i
I1
I I
DETAIL BCONTINUED) j
i
HERITAGE SHINGLE
FIG. 2 ALTERNATE FASTENING PATTERN
;+--12-112' I, —l�i`�1"�•-
i i i •. �i ;
Common Bond
FASTENERS
{
T� ti f. vti>:n� r .f.;rvr{;w��-.-.�..-:nv.vr.-:ti \ -a••'•p �` ••'n`•� J i� �1
�' :�:�..r{�:?:�tijr::<S!:�r::-i•�..tr..i+',:��•.•. •.r..x•.•�}};xti}7:•:%•.��1.•-{tr`r`''�.�'�c�t:Y.P�{ti{:31.��,.+,��}:^�'�:rv!•;1,. --
f t
1
f i
• 39-318"
HERITAGE SHINGLE
(TUSCALOOSA,AL) i
FIG. 3 ALTERNATE FASTENING PATTERN j
HORIZONTAL NAIL SPACING IN ACCORDANCE WITH FIG.1 OR FIG.2.
VERTICAL NAIL SPACING ALLOWED ANYWHERE WTI'HIN NAIL ZONE.
i
PAINT 1
LINE.
7-778" I —^ —NAIL,ZONE
` EDGE OF
6-118" COMMON
i, BOND
EXPOSURE
a
ACCEPTABLE
FASTENER LOCATION j
DO NOT FASTEN
ALON G_ED GE.OF
COMMON BOND
AK
PREFERRED
FASTENER
LOCATION
11
i ! NOA No.: 15-1215.10
QMWAM11-DAR COUNTY ti !Expiration Date: 12/01/20
I Approval Date: 05/26/16
Page 5 of 6
I
i
i
I
i
HERITAGE WOODGATE&HERITAGE PREmium SHINGtiES
FIG.4 FASTENING PATTERN
All dimensions are in inches i
39-3/8"
1" 7'/z" 6%" I 93/8" 61/2"I 11 71/2"1 I V 13-114"
8 > > G� >I<->
-----------------;--------------;--------------;--------- ----;-';-------i..---� --
-
---------------------------------------------------------------- ------------
--;-
I
6" + 5-5/8"
! Exposure
's I
f I
r
it
'I
END OF THIS ACCEPTANCE
i
I ;
I
J
'I
i
k
NOA No.: 15-1215.10
QMMAMM1•DADE COUNTY Expiration Date: 12/01/20
j I Approval Date: 05/26/16
Page 6 of 6
I' � I
I '
I
I
MIAMI-DAOE :'' i MIAMI-DADE COUNTY
L�1J1lL� PRODUCT CONTROL SECTION
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) ' Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION !' T(786)315-2590 F(786)315 2599
NOTICE OF ACCEPTANCE (NOA) I iww.miamidade.uov/economv
TRI-BUILT Materials Group,LLC
PO Box 70
Rutherford,NJ 07070 j
SCOPE:
This NOA is being issued under the applicable rules and regulations governing'the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to
be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami Dade County Product Control
Section(in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right
to revoke this acceptance,if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply1with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: TRI-BUILT Sand-R SA Shingle,Smooth HT S/A and S/A HT TU Underlayment Products
i
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.i
RENEWAL of this NOA shall be considered after a renewal application has been filed and'there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
11 1
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any
section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade;County,Florida,and followed by the
expiration date may be displayed in advertising literature. If any portion of th6JNOA is displayed,then it shall be
done in its;entirety.
INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA consists of pages 1 through 5. �I
The submitted documentation was reviewed by Gaspar J Rodriguez. II
t
i
I � ,
t NOA No.: 15-1123.06
r�rsrsiaanecourrrr I ; Expiration Date: 09/29/20
Approval Date: 04/28/16
Page 1 of 5
I
I '
I
ROOFING COMPONENT APPROVAL
Category Roofing
I
Sub-Category: Underlayment
Materials: SBS
SCOPE: '
This acceptance is for TRI-BUILT Sand-R SA Shingle,Smooth HT S/A and IS/A HT TU Underlayment Products,
as described in this Notice of Acceptance,for use with approved prepared roof assemblies as described in this Notice
of Acceptance;designed to comply with the Florida Building Code,including the Higli Velocity Hurricane Zone of the
Florida Building Code.
I
TRADE NAMES OF PRODUCTS MANUFACTURED OR L "1BELED BY APPLICANT:
Test Product
Product Dimensions Specification ; Description
Tri-Built Sand-R SA Shingle 36"x 65'rolls ASTM D1970 Self-adhering glass fleece reinforced, SBS
Underlayment modified bitumen roofing underlayment.
Manufacturing Location #1-3
Tri-Built Smooth HT S/A 36"x 65'rolls ASTM D1970 Self-adhering glass fleece reinforced,
Underlayment elastomeric bitumen'roofing underlayment.
Manufacturing Location #1-3
Tri-Built S/A HT TU 39 3/8'x 65 3/5' TAS 103 and Self-adhering glass fleece reinforced, SBS
Underlayment rolls ASTM,D 1970 modified bitumen roofing underlayment.
Manufacturing Location #3
MANUFACTURING LOCATION:
1. Drummondville,Quebec(Canada)
2. Wadsworth,OH
3. Gulport,MS !
j EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Nam�e/Report Date
Underwriters Laboratories,Inc. R21824 UL790 09/11/15
Trinity I ERD 540540.02.13-1 ASTM D1976 02/19/13
S40540.11.13 ASTM D19701 11/19/13
S43530.02.14-1-R1 I TAS 103 I 05/14/14
S44870.04.14-4 'ASTM D1970! 04/10/14
S44870.04.14-1 ASTM D1970. 04/10/14
S44870.04.14-3 ASTM D1970 04/02/14
S40540.10.14 ASTM D197Q 10/31/14
SOPC-SC8520.04.15 TAS'103 ! 04/27/15
I
,
NOA No.: 15-1123.06
DADECOUNTY Expiration.Date:' 09/29/20
�! Approval Date: 04/28/16
Page 2 of 5
i
f
APPROVED ASSEMBLIES:
Deck Type 1: Wood,Non-insulated
Deck Description: 19/32'or greater plywood or wood plank
System E(1): Base sheet mechanically fastened,membrane adhered.
I
Base Sheet: One or more plies of ASTM D226 Type H or ASTM D2626 with a minimum 4"side lap and a
6"end lap mechanically fastened to deck with approved nails d tin caps 6" o.c. at the laps and
two staggered rows 12" o.c.the field of the roll. j
Membrane: One ply of Tri-Built S/A HT TU Underlayment,Tri-Built Smooth HT S/A Underlayment
or Tri-Built Sand-R SA Shingle Underlayment with minimum 3-inL side laps and 6-inch
end laps. Starting at the first course,parallel to the eave;align the membrane carefully by
completely unrolling and setting it exactly where it will be installed. Once aligned,rewind one
half of the length. Gently score the release paper on the high side of this roll, ensuring not.to
cut through the membrane's thickness. Unroll this fust half by eyenlyi peeling back the release
paper while simultaneously and slowly pushing out the membrane. Repeat process for
remaining one half of the length. Once installed,the membrane must be pressure rolled with a
metal or rubber roller. Pressure shall be applied over the entire surface,paying particular
attention to all side and end laps. l
I �
Surfacing: Approved for Mechanically Fastened Metal Roofing,Wood Shake&Shingles,Asphalt
Shingles, Slate, Simulated Slate. I
� f
Deck Type 1: Wood,Non-insulated
Deck Description: 19/32' or greater plywood or wood plank
System E(2): Base sheet mechanically fastened,membrane adhered. I+ j
Base Sheet: One or more plies of ASTM D226 Type H or ASTM D2626 with a minimum 4"side lap and a
6" end lap mechanically fastened to deck with approved mails and tin caps 6" o.c.at the laps and
two staggered rows 12"o.c.the field of the roll.
Membrane: One ply of Tri-Built S/A HT TU Underlayment with minimum 3-in6 side laps and 6-inch
end laps. Starting at the fust course,parallel to the eave,align the membrane carefully by
completely unrolling and setting it exactly where it will be installed. Once aligned,rewind one
half of the length. Gently score the release paper on thelihigh side of this roll, ensuring not to
cut through the membrane's thickness. Unroll this first half byevenly'peeling back the release
paper while simultaneously and slowly pushing out the (membrane. Repeat process for
remaining one half of the length. Once installed,the membrane must be pressurerolled with a
metal or rubber roller. Pressure shall be applied over the entire surface,paying particular
attention to all side and end laps.
The Tri-Built S/A HT TU Underlayment shall be back nailed to deck with approved annular
i ring shank nails and tin caps at a maximum 12"o.c. at the side laps and 6"o.c.at the end laps.
No nails or tin caps shall be exposed.
Surfacing: Approved for Mechanically Fastened Cement or Clay Roof tiles.Tri-Built S/A HT TU
Underlayment may be used with any approved roof the system.adhere'd as specified in their
current NOA using any foam adhesive listed and having:a current adhesive NOA approval.
�I
NOA No.: 15-1123.06
h4lAN110ADECaUNTY ;Expiration Date: 09/29/20
Approval Date: 04/28/16
Page 3 of 5
S
j I
. i I
I'
I
I
t
LBUTATIONS: i
I I
1. Fire classification is not part of this acceptance.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall jbe in compliance with
the applicable building code. Tri-Built S/A HT TU Underlayment,Tri-Built Smooth HT S/A Underlayment or
Tri-Built Sand-R SA Shingle Undprlayment shall be installed in strict coniplianc i,with the applicable building
code.
' i I
3. Tri-Built S/A HT TU Underlayment,Tri-Built Smooth HT S/A Underlayment or Tri-Built Sand-R SA Shingle
Underlayment shall be applied to a smooth,clean and dry surface,free from irregularities. Re-fasten any loose
decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and
debris prior to application. When a smooth,clean and/or dry surface cannot be obtained',the substrate shall be
primed with Elastocol Stick prior to application.
4. Tri-Built S/A HT TU Underlayment,Tri-Built Smooth HT S/A Underlayment or
Tri-Built Sand-R SA Shingle
Underlayment shall not be applied over an existing roof membrane as a recover system but may be applied over a
roofing Base/Anchor sheet underlayment. I
5. Tri-Built S/A HT TU Underlayment is acceptable for use in foam adhesive'set and mechanically fastened roof tile
systems as specified in the surfacing option of the approved assemblies. I; j
6. Tri-Built Smooth HT S/A Underlayment or Tri-Built Sand-R SA Shingle Underlayment Ishall not be left exposed
as a temporary roof for longer than 30 days. j
7. Tri-Built S/A HT TU Underlayment shall not be left exposed as a temporary roof for longer than 180 days of
application.
8. Tri-Built S/A HT TU Underlayment,Tri-Built Smooth HT S/A Underlayment or Tri-Built Sand-R SA Shingle
Underlayment may be used with any approved roof covering listing Tri-Built S/A HT TU Underlayment,Tri-Built
Smooth HT S/A Underlayment or Tri-Built Sand-R SA Shingle Underlayment. If Tri-Built S/A HT TU
Underlayment,Tri-Built Smooth HT S/A Underlayment or Tri-Built Sand!'R SA Shingle Underlayment is not
listed,a request may be made to the Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product
Control Department for approval based on the necessary documentation to;detail'compatibility of the products,
wind uplift resistance and fire resistance results.
.I
9. When applying the membrane in the valley, start at the low point and work to the high point,rolling the
ii
membrane from the center outward in both directions. For ridge applications,center the,membrane and roll from
the center outwards in both directions.
10. Membrane shall be applied to protrusions,slope changes,valley,curb,and other roof top penetration details
before any other sections of the roof.
I
li
I I ,
.f
I
i
I i �
i
I �
NOA No.: 15-1123.06
MtAMIOADEcaUN7Y Expiration Date: 09/29/20
Approval Date: 04/28/16
Page 4 of 5
I ,
1
I
j I
11. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code. r
12. Tiles must be staged onto Tri-Built S/A HT TU Underlayment not to exce Id 10-high,to;the standard maximum
roof pitch of 6:12 for flat tiles and 5:12 for lugged tiles. Lugged tiles staging at slope>5:12 shall use alternate
staging method(bottom file shall be inverted followed by eight tiles high on slope;as illustrated in Figure 1
below).
I ' w
x A
ZI
s ` �
IFI 1
I �"t
I
r$ ..
Figure 1: Alternate Staging Method
At roof slopes greater than the preceding limitations all tiles shall be loaded onto a'nominal 1"x 2"horizontal
batten to prevent slippage. JI
13. All membranes or packaging shall bear the imprint or identifiable markinglof the manufacturer's name or logo,
city,state and the following statement. Miami-Dade County Product Control Approved; or the Miami-Dade
County Product Control Seal as shown below.
i
MIAMI•DADE COUNTY
A
END OF THIS ACCEPTANCE j
I
i
I
1
I r
I
I
I i
iI r
i
' NOA No.:15-1123.06
Fsdl' i06DECOUNTY Expiration Date: 09./29/20
Approval Date: 04/28/16
Page 5 of 5
I
I i
I ,
I
MIAMI-DADS `°x4
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) i 11805 SW 26 Street,Room 208
-,BOARD AND CODE ADNIINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) w;ww.miamiaade.Eov/economy
Tamko Building Products,Inc.
:220 W.Fourth Street
' Joplin,MO 64801
SCOPE: r
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER—Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Halving Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(in Miami-Dade County).and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this
product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. RER reserves the!right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code. h
DESCRIPTION: TAMKO Hip&Ridge Shingles
I
I
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of theNOA is displayed,then it shall be done
in its entirety. i
1 INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
t shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA#13-0917.11 and consists of pages 1 through 5.
The submitted documentation was reviewed by Gaspar J Rodriguez.
JIN I
q dr � i NOA No.:14-1001.08
MiaMi•oAnE C=OUNTY J f Expiration Date: 01/08/19
Approval Date: 10/15/15
Page 1 of 5
� I
f I
i
ROOFING COMPONENT APPROVAL
i
Category: Roofing
Sub-Category: Asphalt Shingles
Materials Laminate !'
Deck Type: Wood
SCOPE:
' I
This approves TAMKO Hip&Ridge Asphalt Shingles,manufactured by TAMMKO Building Products,Inc.as
'I described in:this Notice of Acceptance. j
.j
PRODUCT DESCRIPTION
Product Dimensions Test Specifications j Product Description
Elite Glass-Seal as Hip& 12-1/4"x 36" TAS 110 A heavy weight,3-Tab asphalt 12-1/4"x 36"
.'Ridge Shingles shingle that is¢ut to create three 12-1/4"x 12"
Manufacturing sections 11to be used as is hip&ridge shingle.
Location#1
I
r 12 x 12 Hip&Ridge 12"x 12" TAS 110 A heavy weight,asphalt 12"x 36"shingle with
Shingles perforations to create three 12"x 12"sections
Manufacturing to buse
ed as a hip&ridge shingle.
I Locations#2,3
12-1/4 x 12 Hip&Ridge 12-1/4"x 12" TAS 110 A heavy weig�t;asphalt 12-1/4"x 36"shingle
Shingles with perforations to create three 12-1/4"x 12"
Manufacturing sections to bei ed as;a hip&ridge shingle.
Location#1,3
I
Heritage Vintage 12 x 12 12"x 12" TAS 110 A heavy weight,asphalt 12"x 36"shingle with
Hip&Ridge Shingles perforations tc create!three 12"x 12"sections
Manufacturing to be used as hip&,ridge shingle.
Locations#4
i
'I MANUFACTURING LOCATION
1. Frederick,MD
2. Tuscaloosa,AL
I;3. Joplin,MO h
4. Phillipsburg,KS
i I
i NOA No.: 14-1001.08
MIAM1-DARE COUNTY Expiration Date: 01/08/19
i Approval Date: 10/15/15
Page 2 of 5
i
i I
EVIDENCE SUBMITTED
Test Agency Test Identifier Test Name/Report Date
I
PRI Construction Materials TAS-100(A) TAP-231-02-01 10/12/09
Technologies TAS-100(A) TAP-230-02-01 10/12/09
TAS-100(A) TAP-314-02-61 06/08/15
TAS.100 TAP-043-02261 01/16/11
TAS 100 TAP-071-02701 04/21/03
i
Underwriter's Laboratories,Inc. ASTM D3462 09NK07896 12/16/09
TAS 107 02NK9507i 03/06/02
ASTM D3462 R2919 02/25/02
ASTM D3462 10CA64882 01/28/11
ASTM D3161 R2919 9/17/14
ASTM D3462 R2919 07/23/12
i
LIMITATIONS �I
I '
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
' ratings of this product. �1
2. Shall not be installed on roof mean heights in excess of 33 ft.
j
3. All products listed herein shall have a quality assurance audit in accords ce with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
INSTALLATION j
1. Shingles shall be installed in accordance with Roofing Application Standard RAS:.115.
2. The manufacturer shall provide clearly written application instructions.
1
3. Exposure and course layout shall be in compliance with Detail A&B,attached.
i
4. Nailing shall be in compliance with Detail A&B,attached. �I
LABELING
Shingles shall be labeled with the Miami-Dade Approved Seal as seen below or the wording "Miami-Dade County-
Product Control Approved".
MIAMI•DADE COUNTY j
it !
'
BUILDING PERMIT REQUIREMENTS ii
j As required by the Building Official or the applicable Building Code in order to properly evaluate the installation of
this system; This Notice of Acceptance on its own cannot be used to obtain a building,permit.
I
i
I i
MIAMI•DADE COUNTYNOA No.:14-1001.08
ii Expiration Date: 01/08/19
Approval Date: 10/15/15
Page 3 of 5
i�
I
i,
Ii
i
i
li
I
DETAIL'A
!
TAMKO HIP & RIDGE
or 5-P
E*I06UUPE
6" �� �, f I I 6
`6-2 cr5-g
i NAIL
I I
•; II I i
T"UVtMw
DETAIL B
! ELITE GLASS-SEAL HIP AND RIDGE SHINGLE
Ir
36„
Y. Y
i 2-4
q
r
r
Exposure
� I
I
NOA No.: 14-1001.08
MIAMI•DADE COUNTY Expiration Date: 01/08/19
�Fjgmexmj Approval Date: 10/15/15
i
Page 4 of 5
I
i ;
11 i
i
12 x 12 HIP AND RIDGE SHINGLE
wain
I`^
FRONT' I; BACK
,I � III //f �, Re{•s:eTspe
,STrn�rL\NPfi I J J ,
r I
i
„
12-1/4 x 12 Hip AND RIDGE SHINGLE ;
FRONT- r
r iBACif•
r
125141h /J Re4aasa i'apa,
.j
I JI �
, r
�+ 12'Der,'c�tcrs- •�•___.-��.12':•atGuBlatx-- i� I
I I
I �
I
' IIS
i,
END OF THIS ACCEPTANCE
i
i
I'
NOA No.: 14-1001.08
MIAMI•DADE COUNTY Expiration Date: 01/08/19
Approval Date: 10/15/15
Page 5 of 5
' I
� I '
1 I
M1AM1VDA_1 E MIAMI-DADE COUNTY
o PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) I 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION j Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
I
TAMKO Building Products,Inc. i
220 West 41h Street
Joplin,MO 64801
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade(County Product Control Section
(in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County,) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code. ti I j
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
I
DESCRIPTION: TAMKO Roof Shingles
i I
LABELING: Each unit shall bear a permanent label with the manufacturer's!name or logo; city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted Herein. i
RENEWAL of this NOA shall be considered after a renewal application has been filed and,there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a'revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA asl'an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA .Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA. i
I
-ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
I
INSPECTION: A copy of this entire NOA shall be provided to the user by 1the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No.15-0709.19 and consists of pages 1 through 6.
The submitted documentation was reviewed by Gaspar J Rodriguez.
I �
I
I
NOA No.: 15-1215.10
MIAMI•DADE COUNTY Expiration Date: 12/01/20
Approval Date: 05/26/16
I Page 1 of 6
I
i
I �