HomeMy WebLinkAboutRevisions OFFICE USE ONLY:
DATE FILED: z m• l y PERMIT#-:5L-C- 1-711 -0100�
REVISION FEE: •ism RECEIPT# I-6LA cpc I
PLANNING& DEVELOPMENT SERVICES
BUILDING&CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982-5652
(772)462-1553
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
LOCATION/SITE
ADDRESS:
l Z l I�Cr'iCh 14ti.ac • ��� Sci.��-� L��ie �L1952-•
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
i 'r 'C L— " 1(l SQ Mc
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #:66cc lblOZ I ST. LUCIE CO CERT. #: l8-cou
BUSINESS NAME: taco bs
QUALIFIERS NAME: -Tc- "n
ADDRESS:
CITY: , STATE: F�(- ZIP: SZ
PHONE (DAYTIME):�'-]2- _gam- SN361 FAX:
OWNER/BUILDER INFORMATION:
NAME: -
0nc
ADDRE S: l f �
CITY: (.,_ STATE: (, ZIP: 3�-IG 52�
PHONE (DAYTIME:'?--12- `i-?2- ZSCj]�j FAX:
ARCHITECT/ENGINEER INFORMATION:
NAME: ( hq-
ADDRES'S:
CITY: STATE: ZIP:
PHONE (DAYTIME): FAX:
SLCCC: 9/23/09 wHo"' EV
Revised 06/30/17
Florida Building Code Online Page 1 of 2
t
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FSC Staff SCIS Site Map Links Search
Ff rda
Product Approval
g,z USER:Public User
FL 20838.2
Product Approval Menu>Product or Application Search>Application List>Application Detail CWS SGD 8800
5' X 8' PANELS
I1W. " y
{ 3 FL# FL20838-R2
ITT, Application Type Affirmation
Code Version 2017 RECEIVED
Application Status Approved
FEB 2 7 2018
Comments
Archived ST. Lucie County, Permitting
Product Manufacturer Custom Window Systems Inc.
Address/Phone/Email 1900 SW 44th Avenue
Ocala,FL 34474
(352) 368-692t
kpine@cws.cc
Authorized Signature Kevin Pine
ILE COPY
kpine@cws.cc
Technical Representative Stephen Brooks
Address/Phone/Email 1900 SW 44th Avenue
Ocala,FL 34474
(352) 368-6922 Ext 255
sbrooks@cws.cc
Quality Assurance Representative Jay Lathrop
Address/Phone/Email 1900 SW 44th Ave.
Ocala,FL 34474
(352) 368-6922 Ext 291
jlathrop@cws.cc
Category Exterior Doors
Subcategory Sliding Exterior Door Assemblies
Compliance Method Certification Mark or Listing
Certification Agency Keystone Certifications, Inc.
Validated By Steven M. Urich, PE
Validation Checklist-Hardcopy Received
Referenced Standard and Year(of Standard) Standard Year
AAMA/WDMA/CSA 101/I.S.2/A440 2011
ASTM E 1886 2005
ASTM E 1996 2009
TAS 201/202/203 1994
Equivalence of Product Standards
Certified By
I affirm that there are no changes in the new Florida
Building Code which affect my product(s)and my product(s)
are in compliance with the new Florida Building Code.
Documentation from approved Evaluation or Validation Entity Yes No N/A
FL20838 R2 COC 6thEdFBC-FL20838.pdf
lions-.//tloridabuiidinL,.oi-L/nr/nr ann dtl.asnx?Daram=wGEVXOwtDatbxPaOD"Tr%2bXw... 2/27/2018
Florida Building Code Online Page 2 of 2
Product Approval Method Method 1 Option A
Date Submitted 08/09/2017
Date Validated 08/09/2017
Date Pending FBC Approval
Date Approved 08/15/2017
Summary of Products
FL# Model,Number or Name Description
20838.1 SGD 8800 Sliding Glass Door 8800 Series-4'X 8'Panels
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL20838 R2 C CAC 138-1394CAR.Odf
Approved for use outside HVHZ:Yes FL20838 R2 C CAC 138-1395CAR.Ddf
Impact Resistant:Yes FL20838 R2 C CAC 138-1397CAR.Odf
Design Pressure:N/A FL20838 R2 C CAC 138-1398CAR.odf
Other: Impact vinyl sliding glass door with light FL20838 RZ C CAC 138-569CAR.odf
reinforcement,standard sill riser,and annealed laminated FL20838 R2 C CAC 138-570CAR.Ddf
glass to+/-DP50.Design pressure+/-65 with light Quality Assurance Contract Expiration Date
reinforcement,standard sill riser,&heat strengthened 04/18/2020
laminated glass. Installation Instructions
FL20838 R2 II CWS-1150-Rl.odf
Verified By: Lucas Turner FL PE 58201
Created by Independent Third Party: Yes
Evaluation Reports
FL20838 R2 AE EvalReoort1150-111.odf
Created by Independent Third Party:Yes
20838.2 SGD 8800 Sliding Glass Door 8800 Series-5'X 8'Panels
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL20838 R2 C CAC 138-1601CAR.odf
Approved for use outside HVHZ:Yes FL20838 R2 C CAC 138-1602CAR.odf
Impact Resistant:Yes FL20838 R2 C CAC 138-571CAR.odf
Design Pressure: +80/-80 Quality Assurance Contract Expiration Date
Other: Impact vinyl sliding glass door with heavy 04/22/2020
reinforcement and high sill riser to+/-DP80. Installation Instructions
FL20838 R2 I1 CWS-1151-RI.Ddf
Verified By: Lucas Turner FL PE 58201
Created by Independent Third Party: Yes
Evaluation Reports
FL20838 R2 AE EvalReoortl151-111.odf
Created by Independent Third Party: Yes
20838.3 SGD 8800 Sliding Glass Door 8800 Series-4'X 10'Panels
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL20838 R2 C CAC 138-1610CAR.Ddf
Approved for use outside HVHZ:Yes FL20838 R2 C CAC 138-1611CAR.Ddf
Impact Resistant:Yes FL20838 R2 C CAC 138-573CAR.Ddf
Design Pressure: +65/-65 Quality Assurance Contract Expiration Date
Other: Impact vinyl sliding glass door with heavy 05/11/2020
reinforcement and standard sill riser to+/-DP65. Installation Instructions
FL20838 R2 II CWS-1152-Rl.Ddf
Verified By: Lucas Turner FL PE 58201
Created by Independent Third Party: Yes
Evaluation Reports
FL20838 R2 AE EvalReoort1152-R1.Ddf
Created by Independent Third Party: Yes
Back Nekt
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an WEED employer.Coovriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida taw,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to
section 455.2 75(l),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emads provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
21Z M® ®
Credit Card
Safe
httos:Hfloridabuildinp.ora/pr/i)r am) dtl.asox?varam=wGEVXOwtDQtbxPciODTr%2bXw... 2/27/2018
URNER 1239 Jabara Ave.
North Port, FL 34288
ENGINEERING & Ph. 941-380-1574
TCONSULTING, INC. FBPE C.O.A. #29779
Evaluation Report 1151-R1
November 21,2016
Product Description: Series 8800 Vinyl Sliding Glass Door, Large Missile Impact Resistant, 5' nominal
panel widths,96"door heights,with design pressures of+/-80 psf,with heavy panel reinforcement
required as shown in CWS-1151-RI
Manufacturer: Custom Window Systems, Inc. 1900 SW 44`h Ave,Ocala, FL 34474
Statement of Compliance: This report evaluates the above-listed product per the requirements of FAC
Product Approval Rule Chapter 61 G20-3.005 (4). This product complies with the requirements of the 5`h
Edition(2014)Florida Building Code including the High Velocity Hurricane Zone. The product testing
standards performed are outlined below.
Technical Documentation:
1) This report,prepared by Lucas A.Turner, P.E.,at 1239 Jabara Ave.,North Port, FL
2) Approval drawing CWS-t 151-R1,signed and sealed by Lucas A.Turner, P.E.
3) Keystone Certifications CAR documents 138-571, 160 1.0,and 1602.0
4) Test Reports F1575.04/14-401-18/44, from Intertek/ATI,Tampa, FL(TAS testing signed/sealed
by Justin P. McDonald),and CWS-010-02-03/04,by PRI Construction Materials Technologies,
Tampa, FL(TAS testing signed/sealed by Zachary R. Priest),with testing performed: TAS
201/202/203-94,AAMA/WDMA/CSA 101/I.S.2/A440-1 I, ASTM E 1886-05,ASTM E 1996-09
5) Supplemental Calcs. to support 115 151-R1,signed and sealed by Lucas A.Turner, P.E.
Installation: Units must be installed according to approval document CWS-1151-R1.
Limitations of Use: This product:
• May be used in sizes,design pressures,and with max. glass DLO sizes as shown in CWS-I 151-RI
• is large missile(91b 2x4, 50 ft/s) impact resistant and does not require the use of shutters
• May be used in the High Velocity Hurricane Zone and ASTM Wind Zone 4 areas
• Requires laminated glazing as shown in CWS-1151-R1, with Kuraray(prev. Dupont) .090"
SentryGlas interlayer per Miami-Dade NOA 14-0916.11
• Requires Vision Extrusions PVC frames in accordance with NOA 15-0528.14
Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire,a financial
interest in Custom Window Systems or in any company manufacturing or distributing products for which
this report is being issued. I do not have,nor do I intend to acquire,nor will I acquire,a financial interest
in any other entity involved in the testing or approval process of this product.
010111011014
0 NOREW �i,
Lucas A. ''; No 58201 Z
Turner
2016-11-21 gip:, STATE of ,'�� 11/21/2016
10:37+19:00 0,<�•,,,* P; �` Lucas A. Turner, P.E.
°R��''��N � FL PE #58201
•,,��,4f0�Q;E,`���
SLIDING GLASS DOOR - LARGE MISSILE IMPACT GENERAL NOTES: 0=00 0
1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND WINDOW SYSTEMS•
MANUFACTURED TO COMPLY WITH THE FLORIDA BUILDING 1900 SW 44TH AVE.
CODE(FBC),CURRENT EDITION AND IS RATED FOR USE IN THE OCALA.FLORIDA 34474
HIGH VELOCITY HURRICANE ZONE(HVHZ)AND IS RATED FOR VWWV.CWS.CC
WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED IN
ASTM E 1996 PER THE FBC.
8800 VC�±
2.GLAZING OPTIONS:(SEE SHEET 3) P
2331}"4 PANEL WIDTH' SLIDING GLASS
3.APPROVED CONFIGURATIONS INCLUDE BUT ARE NOT DOOR-IMPACT
LIMITED TO:
60 POCKET "XO "Ox"."XX","OXO "XXX "OXXO"."XXXX",
MAX.PANEL WIDTH "PX" "PAX" "PXXX" "PAY"" "PXXP" "PXXXXP" "PXXXXXXP",
"PXXXXXXXXP" m r
2 TRACK,3 TRACK,4 TRACK z
4.DESIGN PRESSURE RATING. J
-NEGATIVE DESIGN LOADS BASED ON,TESTED PRESSURE m m
52 AND GLASS TABLES ASTM E-1300-04. V)
GLASS DLO -POSITIVE DESIGN LOADS BASED ON,TESTED PRESSURE. o Z
96"
MAX B WATER INFILTRATION TEST PRESSURE AND GLASS TABLES ?
UNIT
C B ASTM E-1300-04. w
B
HEIGHT B 11 U Z W
b 5.ANCHORAGE:THE 33 1/3%STRESS INCREASE HAS NOT BEEN a O 'm
USED IN THE DESIGN OF THIS PRODUCT.SEE SHEETS 10-11 ti a
M- X X II X X F FOR ANCHOR DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 0 0=
PANEL II 12 WAS USED FOR WOOD ANCHOR CALCULATIONS. O tUn
HEIGHT II
0 LU
64 y II 12 6.PRODUCT APPROVED FOR IMPACT USE. SHUTTERS ARE NOT Q
GLASS N REQUIRED. z
DLO II tuu++++
7.ALL FRAMES ARE PROCESSED AND SCREWED ���� +++,,
TOGETHER.VENTS ARE PROCESSED AND THERMAL WELDED 4Q6 P.;C..E 3F G'Qi���
TOGETHER.
S.SERIES/MODEL DESIGNATION SGD-6800. Z-:• No 56201 '��
9.THE DESIGNATION X AND O STAND FOR THE FOLLOWING:
A -�-- X=OPERABLE SASH,0=FIXED SASH,P=POCKET/HOOKSTRIP 0=•• STATE Of •:�:
:c<
12 12 11 10 SECTION
AIONLLOS APPLY TO ALL CONFIGURATIONS INA
SIMILAR
11.WEEP SLOTS=1/2"x 1"LOCATED Q BOTH ENDS.
11/21/2016
LUCKS A. LUCAS A TURNER,P.E.
Turner FL PE#58201
1239 JABARA AVE.
2016-11-21 NORTH PORT,FL 34288
10:37+19:00 PH.941-380-1574
SHEET DESCRIPTION
TABLE OF CONTENTS
GENERAL NOTES AND
GENERAL NOTES&ELEVATIONS....1 ELEVATIONS
SECTION VIEWS.................................2
DRAWN BOM&GLAZING DETAIL....................3 !DESIGN PRESSURE IMPACT RATING! r A
ANEL SIZE
EXTRUSIONS...................................4-5 MAX.. RATING BLZ 05/16/16
TRACK WIDTHS..................................8 TvvGn wrV.
ANCHOR SCHEDULE&NOTES........7 60-15/16"x 93-3/8" +/-80 PSF LARGE MISSILE CWS-1151 1
ANCHOR PATTERNS......................8.9
INSTALLATION DETAILS.............10.11 •(4)PANELS SHOWN;HVHZ LIMITED TO MAX.(9)PANELS. OUTSIDE HVHZ,UNLIMITED NUMBER SHEET
OF PANELS IS ALLOWABLE AS LONG AS INDIVIDUAL PANELS DO NOT EXCEED PANEL SIZE AS SHOWN. 1.30 1 OF 11
41 28 11 40
14 WINDOW SYSTEMS
35 1900 SW 44TH AVE.
37 37 OCALA,FLORIDA 34474
12
60 38 q O p WWW.CWS.CC
a14 10 a
z9 26 23 d 8800 PVC
Qg 39
U o q o p 37 14 SLIDING GLASS
a a
oa 39 DOOR- IMPACT
30 d b 19,20,21,58 0
0 37 W
14
0 36 a O
15
�o �t
19,20,21,58 1y m m
U
33 18 37 14 6 Z O
35 SECTION VIEW B-B
13 crV)
68 39 R O LLJ
CL
w a
dsoo 4 0 000�
LL,
W
� N
0
12 Z
54.55 l �`
36 SB 19 �Py• EN
.�..........
CF..,`.
J' No 58201
16 D q *� • *
'^'' 0 :9•• STATE OF �tuZ
22 36
��i s/ONAL E'l�•`�
FIXED PANEL
33 ATTACHMENT Z
36 0 11/21/201
32 17 18
LUCAS A.TURNER,P.E.
FL PE#58201
8 1239 JABARA AVE.
23 NORTH PORT,FL 34288
PH.941-380-1574
630�
SHEETDESCRIPTION
O 0 � SECTION V
IEWS
3
LJ �Ll
39 27 ALTERNATE SILL RISER VIEW ALTERNATE SILL RISER VIEW DRAWN8Y DA
TE
SECTION VIEW A-A LIMITED TO+65 LIMITED TO 180 BLZ 05/16/16
NO SILL RISERw a V_
NOTES:
ITEMS NOT SHOWN FOR CLARITY: 1)INSTALLATION W/NO SILL RISER ALLOWED TO THE FULL DP'S INDICATED ABOVE,IN LOCATIONS WHERE WATER INFILTRATION RESISTANCE CWS-1151 1
20.24-26,31.55-58,61-62,64-66 IS NOT REQUIRED.SUCH AS BUT NOT LIMITED TO LOCATIONS WHERE AN OVER HANG IS PRESENT THAT IS AS WIDE AS THE WALL IS TALL. SCALE SHEET
1.3 2 OF 11
PARTS LIST PARTS LIST
ITEM I PART# IDESCRIPTION VENDOR MATERIAL ITEM PART DESCRIPTION Mmark
MATERIAL
1 GLASS SEE THIS SHEET 51 S-2058 Screen,3-Track Sill _ Aluminum WINDOW SYSTEMS2 K6161 2-Track Sill Vision PVC52 52059 Screen,Sna Cover Aluminum 1900 SW 44TH AVE.
3 K6163 3-Track Sill Vision PVC 53 5-2070 Screen,Interlock Aluminum OCALA,FLORIDA 34474
4 H 6165 4Track Si0 Vis on PVC 54 P-5477 Bloek Anti-Lrft N bnwww.CWS.CC
5 K6160 2-Track Head/Jamb Vision PVC 55 P-5559 Screw,#14 x 4"PH PN SMS Steel
6 K6162 3-Track Flead/Jamb Vision PVC 56 P-4269 Screw,#8 x 1"PH PN Tek Fastenal Steel $$QQ PVC
7 K6164 4-Track Head/Jamb Vision PVC 57 P-3556 Screw,#8x2.5'PH FL Tek Fastenal Steel
8 S-2064 Roller Track Insert Keymark Aluminum 58 P-4962 Screw,#8 x 3"PH FL Tek Fastenal Steel 25
SLIDING GLASS
9 S-6171 Cover,Sill Track Vision PVC 59 P-5565 Screw,#12 x 1 1/2"PH PN SMS Fastenal Steel FRAME CORNERS DOOR - IMPACT
10 S-6169 Cover,Interlock Vision PVC 60 P-5566 Screw,#12 X 21/2"PH PN SKIS Fastenal Steel MECHANICALLY FASTENED
11 56172 Cover,External ReinforcementIP-Hook Vision PVC 61 P-3609 Bumper,Panel Stolb Parker Seals Rubber
12 56175 Track Filler,Frame Vision PVC 62 P-4291 Panel Stop Housing M&M Nylon m Lu
13 K6166 Panel Stile/Rail Vision PVC 63 P-5479 Foam Block,Open Cell,0.844"x 0.531"x 1" Lamatek z o
14 K6168 Interlock,Snap-On Vision PVC 64 P-5492 Gasket,Frame Assembly,2-Track Lamatek Butyl
15 H-6167 Astragal Vision PVC 65 1 P-5493 Gasket Frame Assembly,3-Track Lamatek Butyl m m
16 F-1-6170 Glazin Bead,I.G„1" Vision PVC 66 P-5494 Gasket,Frame Assembly,4-Track Lamatek Buryl CO
17 K2060 Sill Riser,2.875" K mark Aluminum 67 P-4659 Dust Plug,1-1/4"x 3"x 0.5" UttraZ OZ
18 H-2062 Sid Raw.4.067' K mark Aluminum 68 P-4366 Dust Plug,1"x 3"x 1" tfab
fab19 P-5517 Panel Guide,Interlock Bear's Metal Alum num 69 Screen,S irxi lastics Rubber wj
20 P-5558 Su rt Channel,Bot Rail,Interlock Bear's Metal Aluminum 70 Screen,Cloth O21 P-5511 Cover,Panel Guide,Interlock Lawrence Ion 71 Duraseal IGS car nex AIuMB I ai a
22 P-5516 Bracket,Fixed Panel Bear's Metal Aluminum PANEL CORNERS
THERMAL WELD C N
23 P-3300 Wisp-0.280"x 0.187"Back,Fin,Black Ultrafab 1:8 Q W
24 P-3438 Backbeddin ,Purfeet Glaze"H"Hot Men Henkel/Sika Silicone
25 P-3514 Screw,#10 x 2"Ph Comb Hd Fastenal Steel j
26 P-3587 Screw,#8 x 1"PH FL TEK-Roller AsmlMortse Lock Fastenal Steel 1"OVERALL Z
28 P-3789 Handle Set with Thumb Turn Amesbury Plastics bnq"TEMPERED ,%��`�PpOREw
29 P-3792 Kee Amesbury
"AIRSPACE ;JVP4P
29
P`;
------ -
30 P-3793 Multi-Point Mortise Lock Amesbury J"HEAT STRENGTHENED .,� No 58201 •:1:S
31 P-4250 Screw,#10 x 2.5"PH PN SMS-Keeper Fastenal Steel
"LAMINATED
32 P-5287 Tandem Roller Ass ,2.125"Dia WtmN Amesburytrz
090 SGP INTERLAYER "p: STATE Of .Brz
33 P-5438 Setting Blocks,0.090"x0.875"x 1.5" Franke Lowe Rubber %O�•, o p•:4V
35 K2068 Reinforcement,Astragal Ke mark Aluminum �!iFS.<........O•'
36 -1775 Reinforcement,Lock Stile/Rails K mark Aluminum g"HEAT STRENGTHENED ���.,S�ONA;E?•`�
37 K2111 Reinforcement,HD,Interlock Keyrriark Aluminum .� y
38 52071 Reinforcement,External,Interlock Ke mark Aluminum i`•'�
39 52069 Frame Insert,Installation Anchors Ke mark Aluminum 16
11121/2016
40 K2063 P-Hook Keyrnark Aluminum 33 "GLASS BITE
LUCAS A.TURNER.P.E.
41 52065 P-Hook Adaptor Keymark Aluminum FL PE#58201
42 52048 Screen,Astragal Keymark Aluminum 1239 JABARA AVE.
43 52050 Screen,1-Track Head Keymark Aluminum 71 2a cuLAZEH NORTH PORT,FL 34288
44 H•2051 Screen,1-Track Jamb Keymark Aluminum PH.941-380.1574
45 52052 Screen,1-Track Sill Keymark Aluminum SHEET DESCRIPTION.
46 52053 Screen,2-Track Head Keymark Aluminum 13 BOM AND GLAZING
47 52054 Screen,2-Track Jamb Keymark Aluminum DETAIL
48 52055 Screen,2-Track Sill K mark Aluminum I� �I
49 52056 Screen,3Track Head K mark Aluminum U \l1I DRAWN Y A
BLZ 05/16/18
50 52057 Screen,3-Track Jamb KeYmark Aluminum 0wcu v.
CWS-11 S1 1
°L SHEET
1:2 3 OF 11
,5 40 i3
13
WINDOW SYSTEMS I\ /f
t> Q D 19DO SW 44TH AVE.
1766 �Oa❑':::1Oa��O� 4 OCALA,FLORIDA 34474
17 ❑ D WWW.CWS.CC
4,71
1,. 2T, —
2-Track Sill-6161 i8
_�„ a1�„ A" L 8800 PVC
SLIDING GLASS
D O O 9 3 iH Sill Riser-2060 DOOR-IMPACT
173„ ^J �1 O U `I ❑ 6063-T6
1 UO❑�U❑0��00❑❑C�❑E �J u �o
Sill Riser-2062
3-Track Sill-6163L u
Panel Head/Sill/Stile-6166 6063-T6 p
1 e Astragal-6167 P-Hook-2063
6063-T6
m m
9 4 p Z
���� �� T
it
°D�O0o=O1oaDM❑o❑❑�❑o� , ,,.. ► I 2 39 0. Z w
rib 2” o.,ab a
rn o-
4-Track Sill-6165I f Reinf.,Ext-Interlock Reint.,Frame-2069 O
L 2071 6063-T6 w v
5 6• o00 ,4 2 41 6005-T6
241"
P-Hook Adaptor-2065 - p
5 Lock Stile-2086 1 Z
t3 6063-T6
i
1-8 � � � 2 � jADRE, ``�.��PNpREWLj
2-Track Head/Jamb-6160 1t 1 6 � Jt• No 58201 •'�1�Z
Cover,Ext 1 &
-67
Hookstrip 6772
:.9 STATE OF
Cover,Interlock-6169 Reinf.,Lock Stile-1775 %,
6005-T6 ',FS•*o a i..
0�J r�[��� r0��J 11 _ L�-.-1- 37 liryrrr
81=1=101=;=Oa�7=0B -T Jir—�—I�L 2 35 --11, rL-
8
1/2016
3-Track Head/Jamb-6162 9 I 11/.TURNS
Roller Track Insert-2064 LUCAS A.TURNER,P.E.
Cover,Sill Track-6171 6063-T5
FL PE#56201
10 t 1239 JABARA AVE.
B
D B 2 NORTH PORT,FL 34288
�4 �47 H DEHCR P110N0-1 574
5
,
1
16 39
o�ooa�000�aoo�ooa -
1 15s" Reint.,HD Interlock-2111 EXTRUSIONS
4-Track Head/Jamb-6164 T 6005-T6 Awn V DAT
t2 BLZ 05/16/16
IG Glazing Bead-6170 Reint.,Astragal-2068 DWG a V.
Track Filler-6175 6005-T6
CWS-1151 1
SHEET
NOTE:ALL EXTRUSIONS ARE RIGID PVC UNLESS OTHERWISE NOTED. 1:2
4 OF 11
-1 Z �Tg
tz.. .. �S/Wln�(�
45 T_ STEMS f/(lt'�
j t 1900 SVV 44TH AVE.
OCALA,FLORIDA 3447144 I
.. W
T_
WW.CWS.CC
Screen,1-Track Sill-2052
Screen,1-Track Head-2050
O O O 5'Q' 8800 PVC
SLIDING GLASS
DOOR-IMPACT
ifi Screen,2-Track Sill-2055 T6 .tom• ,.. �
W
TS Bracket.Fixed Panel _ I� F
m
Screen,2-Track Head-2053 P-5516 a
o
N ..
49 b O p U)
—Jt 2 O
Of vt
T— T9 L i6 >
LLI
Screen,3-Track Sill-2058 > C 0
Screen,3-Track Head-2056 5a ( r
CL
=— 1 oll
vVi
2 a4 4.. �r (3 � az I IIIIo
253 I 35" TG Z,riH.u.rper
1g 2t.. � {.fOREbV
L Screen.Snap Cover-2059 4 Block,Anti-Lift ` Py E •. rG�
L P-5477,Nylon
S
I Screen,Interlock-2097 I J No 58201 :�'P
Screen,1-Track Jamb-2051 *; +
Screen.Astragal-2048 =o: cC
L -5):. STATE OF W
�O� F�ORtOP:\=iu.
ONA-l,',
,
47 T13'
1
2
1.. 16 2 tg"--I 19 7,, 21
11/21/2016
Screen,2-Track Jamb-20541 2D LUCAS A.TURNER,P.E.
I I �nl FL PE#58201
III 1239 JABARA AVE.
I 0 I I I II II NORTH PORT,FL 34288
I I I I II
'L
IIIIIIII I � IIf=IIiIIiIIl
PH.941-380-1574 0
-157
4
4Tlli SHEEDESCRIPTIONT`Q. O 4° I I 2 PEXTRUSIONS
T9 DRAWN Y A IrI
II I 1111 BLZ 05/16/2016
Screen,3-Track Jamb-2057 II
OWGk
CWS 1152 1
NOTE:ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. panel Guide,Interlock-P-5517 Support Channel,But Cover.Interlock-Reint. SHEET
Rail-Interlock-P-5558 P-5511,Nylon 1:2 5 OF 11
ffl�e �(l1JN!(y®EMS
1900 SW 44TH AVE.
OCALA,FLORIDA 34474
www.Cws.cc
LJ 45.. 8800 PVC
q H-oe0 q H-zoe2 SLIDING GLASS
Q D O Oo O iL DOOR-IMPACT
°o❑❑❑°o❑❑❑°oD `1]o❑❑❑°D❑❑❑°o❑❑❑°o� 1�°D❑❑❑°D❑❑❑°a❑❑❑°o❑❑❑°o1
F
2T Sill w/Riser 3T Sill w/Riser 4T Sill w/Riser QO
8�- m m
Lo
z O
ct: rn
z
i i
t
9 q Lo0.
O o 's
0 Lu
°o❑❑❑o❑❑❑a� �lll° 8=000=0000° °
oO❑ o
z
2T Sill w/1T Screen 3T Sill wt 1T Screen ``1�rr�rrrrrrr•
,��.�`PNORE W T••.
12 13"
No 58201 S
�9= STATE OF
,,••',S70NAlE�����
O •••hurrnu"`
�l000❑❑❑°°❑❑�11 EIDE� �l°o❑❑❑°o❑❑❑°o❑❑❑o❑❑cam°oa z�
v21i2o1s
3T Sill wt 2T Screen 4T Sill wl 1T Screen LUCAS A.TURNER,P.E.
FL PE#58201
s .. 1239 JABARA AVE.
NORTH PORT,FL 34288
PH,941-386-1574
SHEET DESCRIPTION'
TRACK WIDTHS
O
DRAWN BY DATE
eLz os
/1s/1s
❑❑ ❑o ❑0oII cws-1151
,
°L SHEET
4T Sill w/3T Screen 12
6 OF 11
ANCHORS @ ti P-HOOK
MAY, 4"
4p ,
PANEL-TYP ANCHORS WINDOW SYSTEMSa°TYP. TYp4" 3"EDGE OCA A, LTH AVE.
F--e"MAx.TYP. i` TYP. •1 •I 1`, �.1 .1 OF PANEL WWW.CWS.0 DA 34474
TVP.
II 12"MAX. 8800 PVC
21" II O.C.
MAX SLIDING GLASS
II
TYP DOOR-IMPACT
II _
u
II
oiL
II - N
o z
II MID- z O
II _ SPAN X Ln
II OF w >
II PANEL Q W
II co ofa
II
Lu
ao
� o
z
FIXED PANEL
CIRCLED ANCHOR LOCATIONS REQ'D ONLY IN WOOD INSTALLATIONS. (SEE NEXT SHEET FOR DETAIL) CLIP58201 '�11
NOTES �'' •
1.INSTALL TWO ANCHORS AT EACH INSTALLATION LOCATION(SEE LAYOUT DETAILS ON SHEETS 8&9),EXCEPT FOR 2T SILL&WOOD INSTALLATION LOCATIONS.SEE SPECIAL LOCATIONS AND SPACING FOR 2T SILL pi STATE OF :4v
(SHEET 8).INSTALL ONE ANCHOR AT EACH WOOD INSTALLATION LOCATION(CIRCLED). SILL ANCHOR SPACING SAME AS HEAD FOR 3T AND 4T. INSTALL ONE ANCHOR AT EACH LOCATION IN HOOKSTRIP. '✓°<O Fi OD P✓G�?��
2.SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX.ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16"IS PRESENT. LOAD BEARING SHIMS SHALL BE ,,l�SS��NA�EN���,
CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER.WOOD SHIMS ARE NOT ALLOWED.
3.ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 10. i
11/21/2016
4.ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST LUCAS A.TURNER,P.E.
BE PROTECTED TO PREVENT REACTION. FL PE#58201
5.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM 1239 ORT.PAVE.
P
SPECIFIED IN TABLE 1,SHEET 10. NORTH PORT, 34288
PH.941-380-1-1 574
S.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS,EMBEDMENT SHALL BE BEYOND WOOD BUCKS,IF USED,INTO SUBSTRATE. SHEET DESCRIPTION
INSTALLATIONS TO SOLID CONCRETE OR GROUT-FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. ANCHOR SCHEDULE AND
INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. NOTES
7.A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS:3"FOR SOLID CONCRETE,6"FOR CMU MASONRY,1"FOR WOOD AND METAL. DRAWN BY DA
TE
BLZ 05/16/16
8.WOOD OR MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. DWG a v.
SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET,SHEET 10. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. CWS-1151 1
9.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS. AL SHEET
FMA/AAMA 100(FIN WINDOWS),FMA/AAMA 200(FLANGE WINDOWS), FMA/WDMA 250(BOX WINDOWS),FMA/AAMA/WDMA 300(EXTERIOR DOORS) 1.25 7 OF 11
INTERLOCKS
c ASTRAGAL 2r'O.C.MAX
6"TYR PANEL P-HOOK 6"TYP. TVP. WINDOW SYSTEMS
WIDTH 3"TYP,I-- 3-TYP.
1900 SW 44TH AVE.
OCALA,FLORIDA 34474
WWw.0 WS.CC
6 TYP 8800 PVC
SLIDING GLASS
2}a DOOR - IMPACT
2T SILL 2T JAMB TYP. �2
TYP.
INTERLOCKS
E ASTRAGAL
6"TYP. PANEL P-HOOK 6"TYP 21" TY M:.X ..I
--{ N
I WIDTH 1+4"TYP.--1 4"TYP m m
O
z
z O
¢ rn
w z >
0 3..TYP o 3.. Q O 0:
5 Ya N d
TYP.
O �
° o p0 tV
a
16Z
;Q"TYP. h:L+tl bo u4lLs 3TJAM8P. L ." OREW''
"TYP. 3T SiLL uLu -„�,- .`� N ''�
P ........TG��
f TYP. 5EF,•.;Ay�:
INTERLOCKS zNo SB201 ,9
ASTRAGAL '*: • '.*
PANEL P-HOOK 5"TYP. 211,O.C.MAX �'d; t a z
r--6 Tv?.-{ '9: STATE OF -��
rI- TYP. O•.
An
f--4"TYP. 4 TYP. ��
tSfois�ONA; %YH l��`�
1 z�
4;" 11/21/2016
TVP.
4 3 TYP LUCAS A.TURNER,P.E.
FL PE*58201
1239 JABARA AVE.
0 o I NORTH PORT,FL 34288
PH.941-380-1574
SHEET DSCRI ION
ANCHOR PATTERNS
(JAMB&SILL)
ONi TYP.
d DRAWN V
4T SILL 4T JAMB ���TYP. E3 LZ 05/16/16
DwGa REv.
CWS-1151 1
NOTE.Ct=CENTERLINE OF INTERLOCK OR ASTRAGAL SCAL- SHEET
CIRCLED ANCHOR LOCATIONS REQ'D ONLY IN WOOD INSTALLATIONS. 1:5 8 OF 11
f �q
INTERLOCKS // 77nRvf��m
HOLE PATTERN ASTRAGAL ILlUU'�7(f((�/
f FORANTI-LIFT P-HOOK WINDOW SYSTEMS
ro
BLOCK ANC HORS
6"TYP.--{ PANEL 1900 SW 44TH AVE.
WIDTH F�4"TYP--i OCALA,FLORIDA 34474
WWW.CWS.CC
a fYP r 8800 PVC
0 o SLIDING GLASS
0
-- - TYP DOOR- IMPACT
}
4..TYP. 'TYP. 2T HEAD 4"TY "-
m ui
f ^ �
INTERLOCKS N
HOLE PATTERN ASTRAGAL J �;
PANEL FORANTI•LIFT P-HOOK m m
6"TYP.�-{ WIDTH BLOCK AnCILL z
noRs
4"TYP. 4"TYP.
� 2 O
_ _ y
0 1 ol w
- aoit
i~ CL
`Y P a it
Lu
w
of o o o C
`—\ 1"TYP 2
DREW�T4i
3T HEAD .•va?.��cEhsF�Qy'o
INTERLOCKS
f HOLE PATTERN ASTRAGAL .fl
FORANTI-UFT p-HOOKSTAT ¢�
PANEL eLOCKANCHORS tE OF ,4
64v Z
"TVP.--- WIDTH �—4"TYP. 4"TVP. i'�,��OSFC 0 R L O r��\-��,
�"i,S/ONA;E,
0 0 0 0 0 XZ
11/21/2016
0 0 43" LUCAS A.TURNER,P.E.
-- - TYP. FL PE#58201
1239 JABARA AVE.
o c; 0 0 o NORTH PORT,FL 34288
PH.941-380-1574
SHEET DESCRIPTION.
0
TYP ANCHOR PATTERNS
(HEAD)
Pn.r. _.. ... DRAWN BY
BLZ 05/16/16
4T HEAD # v.
CWS-1151 1
NOTE- a CENTERLINE OF INTERLOCK OR ASTRAGAL AL - SHEET
CIRCLED ANCHOR LOCATIONS REO'D ONLY IN WOOD INSTALLATIONS. 1:5 9 OF 11
2 TRACK HEAD ANCHORAGE
MIN.EDGE DIST.
v4"MAX WINDOW SYSTEMS pay SEE TABLE 1 SEE LAYOUT ON BHT 9 1900 SW 44TH AVE.
39,FRAME INSERT REQ'O AT OCALA,FLORIDA 34474
ALL FRAME ANCHOR LOCATIONS 39,FRAME INSERT REO'D WWW.CWS.CC
AT ALLFRAME ANCHOR
LOCATIONS
SUBSTRATE
BY OTHERS MIN.EMBEDMENT 8800 PVC
SEE TABLET SEE TABLET SLIDING GLASS
PERIMETER SEALANT SEE LAYOUT DOOR-IMPACT
BY INSTALLER OGU �7L.J ON SHT 8
INSIDE AND OUT MAX.
SHIM o
m LU
zz
MIN EDGE DIST p
SEE TABLE 1
PERIMETER SEALANT m m
INTERIOR COMPLIANT WITH AAMA 800
BY INSTALLER INSIDE AND OUT O
Z
INSTALLATION ANCHOR
SUBSTRATE BY OTHERS U)
SEE TABLE 1 MIN EMBEDMENT Elf w Z j
SEE TABLE 1 SEE TABLE 1
O
W
SEALANT BETWEEN SILL (L I.-
RISER AND FRAME BY 8 HORIZONTAL SECTION 0
INSTALLER \,2,1 2 TRACK JAMB ANCHORAGE OW U
PERIMETER SEALANT LUQ
BYINSTALLER
INSIDE AND OUT O
DO NOT COVER Z
WEEP HOLES SUBSTRATE MI SEE TAB EENT � PNORE W�T4",
BY OTHERS VP�•��GENgFG•Q,`.-'
BEE TABLE 1v//A7v4777' `J No 58201
MIN.EDGE DIST. 39,FRAME INSERT REQ'D AT
SEE TABLE 1 ALL FRAME ANCHOR LOCATIONS *' • '
:aa
:9 STATE OF :4
/—A"\VERTICAL SECTION 4�SS
9 2 TRACK SILL ANCHORAGE
PERIMETER SEALANT
COMPLIANT WITH AAMA 800 z^�
BY INSTALLER INSIDE AND OUT
INSTALLATION ANCHOR 11/21/2016
SEE TABLE 1
MIN.EDGE DIST. LUCAS A.TURNER,P.E.
EE TABLE 1 FL PE#58201
1239 JABARA AVE.
SUBSTRATE BY OTHERS MIN.EMBEDMENT NORTH PORT,FL 34288
TABLE 1:APPROVED INSTALLATION FASTENERS SEE TABLE 1 SEE TABLE 1 PH.941-380-1574
SUBSTRATE TYPE ANCHOR TYPE MIN.EMBEDMENT MP EDGE DIST. SHEET DESCRIPTION
CONCRETE,2 0 KSI MIN) 1,4"ITW TAPCON 1-117 4"
--- — — ---- - INSTALLATION DETAILS
CONCRETE 12 85 KSI MIN,) t.4"ELCO ULTRACON - 1-3'4" 2-1l: HOOKSTRIP2 TRACK
1;4"ITW TAPCON OR
1.
2X MIN SOUTHERN PINE(G=055) 3.8" 718"
ELCO ULTRACON �"MAX.SHIM DRAWN BY DATE
2X MIN SOUTHERN PINE(G=0.55) 012 WOOD SCREW 1-318' 718" BLZ 05/16/16
IB GALT£(0 O60')MIN. #12.14 HILTI KWIK-FLEX OR ITW FULL THREAD
STEEL STUD(33 KSI YIELD MIN) TEKS SELF-DRILLING SCREW THRU 0.080' 12 DWG# V.
I!T ALUM.(6063-T5 MN.)OR #12 GRADE 5 SELF-TAPPING; FULL THREAD / C 1 HORIZONTAL SECTION CWS-1151 1
UB"STEEL(33 KSI MIN. DRILLING SCREW THRU 0125" L2 9 HOOK STRIP
HOOKSTRIP OR JAMB FRAME ONLY: 1:4"ELCO ULTRACON 1-314• 2-V2" 1.3 SHEET
HOLLOW OR GROUT-FILLED CMU(AS C-90) 10 OF 11
3 TRACK HEAD ANCHORAGE 1/4"MAX
SEE LAYOUT 39,FRAME INSERT REOD AT INTERIOR
MIN.EDGE DIST. ON SHT 9 ALL FRAME ANCHOR LOCATIONS WINDOW SYSTEMS
SEE TABLE 1.SHT 10 39,FRAME INSERT REO'D
AL1900 SW 44TH AVE.
AT L FRAME ANCHOR
SUBSTRATE LOCATIONS OCALA,FLORIDA 34474
BY OTHERS VWWV.CWS.CC
SEE TABLE 1,SHT 10 MIN.EMBEDMENT
SEE TABLE 1,SHT 10
PERIMETER SEALANT f-101—� 8800 PVC'
BY NSTALLER $Q ��pL,J , SLIDING GLASS
INSIDE AND OUT Q a'MAX
7
SHIM O SEE LAYOUT ON SMT 8 DOOR-IMPACT
INSTALLATION ANCHOR INTERIOR
SEE TABLE 1,SHT 10 Iw-
SEALANT BETWEEN SILL a0
RISER AND FRAME BY
INSTALLER
PERIMETER SEALANT Q O MIN EDGE DIST m m
BYINSTALLER O O SEE TABLE 1 SHT 10
INSIDE AND OUT O N
00 NOT COVER PERIMETER SEALANT Z O
WEEP HOLES COMPLIANT WITH AAMA 800
MIN.EMBEDMENT BY INSTALLER INSIDE AND OUT 0: Ln
SUBSTRATE wj
BY OTHERS SUBSTRATE
SEE TABLE 1,SHT 10 U Z LU
SEE TABLE 1,SHT 10 BY OTHERS MIN EMBEDMENT a O w
39,FRAME INSERT SEE TABLE 1,SHT 10 SEE TABLE 1 SHT 10
MIN.EDGE DIST. SEE LAYOUT ON SHT B REO'D AT ALL FRAME
V
SEE TABLE 1.SHT 10 ANCHOR LOCATIONS F HORIZONTAL SECTION O Vj
�u�1 VERTICAL SECTION 10 3 TRACK JAMB ANCHORAGE C� wp
1/4"MAX � O
10 3 TRACK SILL ANCHORAGE INTERIOR Z
MIN.EDGE DIST. 4 TRACK HEAD ANCHORAGE 39,FRAME INSERT AT AL39. L FE INSERT REO'D
RAME ANCHOR ��`ttNCREW
SEE TABLE 1,SMT 70 SEE LAYOUT REO'D AT ALL FRAME LOCATIONS ,��6 P TG
ONSHT9 ANCHOR LOCATIONS - 4P.•y7 C E N$F•,•Q,y�.=
MIN.EMBEDMENT -J:• No 58201
SUBSTRATE SEE TABLE 1,SHT 10
BY OTHERS *' t
SEE TABLE 1,SHT 10 -'d• '�-
1.0 STATE OF :4i:
PERIMETER SEALANT SEE LAYOUT y��.,T<0 R
BY NSINSTALLDE AND OUT ���0� OoO� l� a'MAX. ON SHT B s`sIONAI E�G`�`
SHIM tutu$Ut
zz
INSTALLATION ANCHOR INTERIOR 11/21/2016
SEE TABLE 1,SHT 10SEALANT BETWEEN SILL LUCAS A.TURNER,P.E.
FL PE#58201
RISER AND FRAME BY
INSTALLER �� MIN EDGE DIST 1239 JABARA AVE.
SEE TABLE 1 SHT 10 NORTH PORT,FL 34288
PERIMETER SEALANT PH.941-380-1574
BYINSTALLER
INS DE AND OUT �Q� } 4>Q I SHEET DESCRIPTION
DO NOT COVER LLLIII
WEEP HOLESMIN.EMBEDMENT INSTALLATION DETAILS
ERIMETE
SUBSTRATE SEE TABLE 1.SHT 10 COMPLIANT SEAL A T 900 3&4 TRACK
BY OTHERS BY INSTALLER INSIDE ANO OUT DRAWN BY DATE
SEE TABLE 1.SHT 10
SUBSTRATE MIN EMBEDMENT BLZ 05/16/16
MIN.EDGE DIST. SEE LAYOUT ALLFRAME SEE TABLE 1,SHT 10 39,FRAME INSERT BY OTHERS SEE TABLE i SHT 10 DWG w V
ANCHOR .
SEE TABLE 1,SHT 10 ON SHT B NCH
AORRREO-DALOCATIONS HORIZONTAL SECTION CWS-1151 1
rr="N VERTICAL SECTION \,LUJ 4 TRACK JAMB ANCHORAGE 3rA7L SHEET
10 4 TRACK SILL ANCHORAGE 1.3 11 OF 11