Loading...
HomeMy WebLinkAboutFL8248_R13_II_WD Track Supplement Chart P1214" MAX 12" MAX 12" MAX 12" MAX 12" MAX 12" MAX CLIPS TO BE EITHER RIVETED, BOLTED, OR WELDED. SEE DETAILS THI\`��i��� v NO. 77945 •• �'� • SZAre of •' ��� S � DWAYNE J. KORNISH, PE 4576 COUNTY ROAD 160 MOUNT HOPE. OHIO FL PE 77945 TX PE 117868 PROFESSIONAL ENGINEER'S SEAL PROVIDED ONLY FOR VERIFICATION OF WINDLOAD CONSTRUCTION DETAILS. PLICE PLATE LOCATION EE SCHEDULE EE CLIP DETAIL LIP LOCATIONS EE SCHEDULE RACK 13 GA MI(\ CONTINU01 WALL ANG 11 GA MIN CLIP SEE SCHEDULE TYPICAL CLIP Jj%jffffA u \I TRACK (3) 1/4"-20 TRACK OR CARRIAGE BOLT WITH 1/4"-20 NUT CONTINUOUS MAX DOOR WIDTH MAX WALL ANGLE ❑ TRACK PSF \� +46.0 PSF/-52.0 (2) 1/4" X 18'-0" +46.0 PSF/-52.0 7/16 SEMI El j TUBULAR R i VI TS O \� ❑ (1) 1/4"-20 TRACK 11 GA MIN �: OR CARRIAGE BOLT CLIP SEE WITH 1/4"-20 NUT SCHEDULE TYPICAL CLIP RIVETING DETAIL RSW 0" 11 GA MIN CLIP 2 j/ �� SEE SCHEDULE 1 (1) 1/4"-20 TRACK 13 GA MIN OR CARRIAGE BOLT CONTINUOUS WITH 1/4"-20 NUT WALL ANGLE �..� — TRACK TYPICAL CLIP WELDING DETAIL DESIGN PRESSURE CHART MAX DOOR WIDTH MAX PSF 9'-0" +46.0 PSF/-52.0 PSF 16'-0' +46.0 PSF/-52.0 PSF 18'-0" +46.0 PSF/-52.0 PSF TRACK SUPPLEMENT CHART www ay n 9 Daltom GARAGE DOORS 3395 ADDISON DRIVE PENSACOLA, FLORIDA 32514 (850) 474-9890 REVISIONS P2 2 INCH TRACK -CLIPS -TEXAS WALL ANGLE 12 FOOT UPDATED BPJ 6/11/03 P3 UPDATED FORMAT. INCREASED ALLOWABLE PRESSURES TO +46.00/-52.00 PSF FOR ALL DOOR WIDTHS. CHANGED "TEXAS WALL ANGLE" TO "CONTINUOUS WALL ANGLE". ADDED SUBSTRATE MOUNTING DETAIL, CHANGED TO TITEN HD ANCHORS GRT 4/2/07 P4 CHANGED FORMAT. ADDED MODELS 9800 AND 8024 WITH OVERLAY TO TRACK CLIP SCHEDULE. GRT 8/21 /07 P5 UPDATED MODELS LISTED IN CHARTS. UPDATED SPLICE & CLIP SCHEDULES. DLP 9/06/07 P6 UPDATE MOUNTING DETAIL DRAWINGS. GRT 10/05/07 P7 UPDATED CHARTS TO ELIMINATE THE USE OF THE #8 CLIP (REPLACED WITH #9 ACROSS THE BOARD). DLP 10/24/07 P8 UPDATED STEEL MOUNTING DETAIL MRB 04/11/08 P9 EXPANDED 1-1/2" TO 1-3/8" DOOR THICKNESS CHART UP TO 14' HIGH. GRT 12/11/08 P10 UPDATED TITLE BLOCK GRT 6/2/10 P11 UPDATED TITLE BLOCK. REMOVED CHART. GRT 11/15/13 P12 UPDATED TITLE BLOCK. ESC 6/15/17 DATE NAME DRAWN 8/21/07 GRT CHECKED 8/21/07 MRB SHEET 1 OF 2 DRAWING PART NO. 307494 REV. P12 5/16" x 1-5/8" LAG SCREW OR EQUIVALENT INTO MIN 2 x 6 NO.2 SPF (G=0.42) OR BETTER AT EACH HOLE OR PAIR OF HOLE LOCATIONS - 2 3/4" ±1" EDGE DIST E60XX MIN. X188 22244 MIN 3/16" THICK STEEL FOR MOUNTIN ln/_\1_\1[llll ` TRACK CLIP —1 /4-20x9/16" TRACK BOLT AND 1/4-20 HEX NUT MOUNTING TO WOOD JAMB DETAIL MOUNTING TO STEEL DETAIL CON( 2 3/4" MIN EDGE DIST OPTIONAL: WALL ANGLE MAY BE ATTACHED TO SUPPORTING STEEL MIN. (1) 1 /4-20x7/8" SELF _ING SCREW WITH 1" O.D. IER AT EACH HOLE OR PAIR OF LOCATIONS IN LIEU OF WELDING No. 77945 • �' -p r = b �/ 7 T •• STATE OF �'- tis ' �ZORIDA /®)VAL 110/11110%e DWAYNE J. KORNISH, PE 4576 COUNTY ROAD 160 MOUNT HOPE, OHIO FL PE 77945 TX PE 117868 PROFESSIONAL ENGINEER'S SEAL PROVIDED ONLY FOR VERIFICATION OF WINDLOAD CONSTRUCTION DETAILS. 3/8" SIMPSON TITEN HD, 2-3/4" MIN EMBED INTO VIN 2000 PSI CONCRETE AT EACH HOLE OR PAIR OF HOLE LOCATIONS WALL ANGLE 1 /4-20x9/16" TRACK BOLT AND 1/4-20 HEX NUT TRACK CLIP TRACK SUPPLEMENT CHART 3395 ADDISON DRIVE PENSACOLA, FLORIDA 32514 (850) 474-9890 REVISIONS P2 2 INCH TRACK -CLIPS -TEXAS WALL ANGLE 12 FOOT UPDATED BPJ 6/11/03 P3 UPDATED FORMAT. INCREASED ALLOWABLE PRESSURES TO +46.00/-52.00 PSF FOR ALL DOOR WIDTHS. CHANGED "TEXAS WALL ANGLE" TO "CONTINUOUS WALL ANGLE". ADDED SUBSTRATE MOUNTING DETAIL, CHANGED TO TITEN HD ANCHORS GRT 4/2/07 P4 CHANGED FORMAT. ADDED MODELS 9800 AND 8024 WITH OVERLAY TO TRACK CLIP SCHEDULE. GRT 8/21/07 P5 UPDATED MODELS LISTED IN CHARTS. UPDATED SPLICE & CLIP SCHEDULES. DLP 9/06/07 P6 UPDATE MOUNTING DETAIL DRAWINGS. GRT 10/05/07 P7 UPDATED CHARTS TO ELIMINATE THE USE OF THE #8 CLIP (REPLACED WITH #9 ACROSS THE BOARD). DLP 10/24/07 P8 UPDATED STEEL MOUNTING DETAIL MRB 04/11/08 P9 EXPANDED 1-1/2" TO 1-3/8" DOOR THICKNESS CHART UP TO 14' HIGH. GRT 12/11/08 P10 ADDED MODEL 8700. UPDATED TITLE BLOCK GRT 6/2/10 Pll UPDATED TITLE BLOCK. REMOVED CHART. GRT 11/15/13 P12 UPDATED TITLE BLOCK. ESC 6/15/17 DATE NAME DRAWN 8/21/07 GRT CHECKED 8/21/07 MRB SHEET 2 OF 2 DRAWING PART NO. 307494 REV. P12