NOTICE OF ACCEPTANCE NOA www.miamidade.¢ov/economv
Gardner Asphalt Corporation
4161 W.71 Avenue INLI:
Tampa,FL.33605
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify,or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Gardner Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA# 15-0707.09 and consists of pages I through 5.
The submitted documentation was reviewed by Alex Tigera.
NOA: 17-0427.10
MIAMM WDE COUNTY Expiration Date: 03/28/18
Approval Date: 08/31/17
Page 1 of 5
-•
a ti.
':sie.'►.yy..: ... . .
ROOFING COMPONENT APPROVAL
Cateeorv: Roofing
Sub-Catej!ory: Underlayment
Material: Asphalt
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
Product Dimensions Specification Descriation
APOC Tuff-Felt 26 36"x 72' rolls ASTM D 226 Type II Asphalt Saturated Felt underlayment,2
Manufacturing square#30.
Location#1, 2
United FGUR20 36"x 72' rolls ASTM D 226 Type I1 Asphalt Saturated Felt underlayment,2
Manufacturing square#30.
Location 41, 2
APOC Tuff-Felt 46 36"x 144' rolls ASTM D 226 Type I Asphalt Saturated Felt underlayment,4
Manufacturing square#15.
Location#1, 2
United FGUR10 36"x 144' rolls ASTM D 226 Type I Asphalt Saturated Felt underlayment,4
Manufacturing square#15.
Location#1, 2
United FGUR70 18"x 72' rolls ASTM D 226 Type II Asphalt Saturated Felt underlayment, 1
Manufacturing square#30.
Location#1, 2
GatorSkin 42"x 285.8' rolls ASTM D 226 Type II Synthetic roof underlayment comprised
Manufacturing of layers of polyolefin film.
Location#3
Weather-Armor CX-L 37.25"x 145' rolls ASTM D 226 Type 11 High strength hybrid underlayment
Manufacturing comprised of two layers of polyolefin and
Location#3 polyester synthetic fabric with a thin layer
of modified bitumen between the two
plies.
Weather-Armor SB-1 36"x 65' 8"rolls ASTM D 1970 Glass fiber reinforced,polymer modified
Manufacturing asphalt,granulated self-adhered
Location#4 underlayment.
Weather-Armor HT3 39"x 65' 8"rolls ASTM D 1970 60-mils thick(nominally),self-adhering
Manufacturing membrane composed of elastic polymers,
Location#4 bitumen,glass reinforcements and a cross
laminated sheet surfacing.
NOA: 17-0427.10
MIAMFW1DEColJNTY Expiration Date: 0328/18
Approval Date: 08/31/17
Page 2 of 5
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
Product Dimensions Specification Description
Weather-Armor FT' 39"x 65' 8"rolls TAS 103 60-mils thick(nominally),self-adhering
Manufacturing membrane composed of elastic polymers,
Location#4 bitumen polyester and glass
reinforcement.
MANUFACTURING LOCATIONS:
1. Tacoma, WA.
2. Eutaw,AL.
3. Hangzhou,China.
4. Springville,AL.
EVIDENCE SUBMITTED:
Test Amu Test Identifier Test Name/Report Date
PRI Construction Materials GGI-100-02-01 ASTM D 226 06/22/12
Technologies GGI-101-02-01 ASTM D 226 06/22/12
GGI-132-02-01 ASTM D 226 04/28/15
GGI-176-02-01 ASTM D 226 09/26/16
GGI-178-02-01 ASTM D 1970 10/25/16
GGI-194-02-01 ASTM D 1970 08/04/17
GGI-196-02-01 TAS 103 08/08/17
APPROVED ASSEMBLIES:
Deck Type 1: Wood,Non-insulated
Deck Description: 19/32° or greater plywood or wood plank
System E(1): Anchor sheet mechanically fastened to deck.
Anchor Sheet: One or more plies of APOC Tuff-Felt 26,United FGUR20,United FGUR70,GatorSkin,or
Weather-Armor CX-L with a minimum 4"headlap and a 6"end lap mechanically fastened to
deck with approved nails and tin caps 6 inches o.c. minimum at all laps and three staggered
rows fastened at 12 inches o.c.minimum in the field of the roll.Nails shall be driven flush and
90 degrees to the roof deck.
Surfacing: Shall be acceptable for use in approved asphaltic shingles,wood shakes,&shingles,quarry
slate,metal roof applications,and as an anchor sheet in roof tile applications.Must Comply with
applicable Roofing Application Standards and Building Codes.
NOA: 17-0427.10
MIAMI•DADE COUNTY
Expiration Date: 03/28/18
Approval Date: 08/31/17
Page 3 of 5
Deck Type 1: Wood,Non-insulated
Deck Description: 19/32° or greater plywood or wood plank
System E(2): Anchor sheet mechanically fastened to deck.
Anchor Sheet: Minimum 2 plies or more of APOC Tuff-Felt 46,or United FGUR10 with a minimum 19"
headlap and a 6"end lap mechanically fastened to deck with approved nails and tin caps 6
inches o.c. minimum at all laps and three staggered rows fastened at 12 inches o.c.minimum in
the field of the roll.Nails shall be driven flush and 90 degrees to the roof deck.
Surfacing: Shall be acceptable for use in approved asphaltic shingles,wood shakes,&shingles,quarry
slate,metal roof applications,and as an anchor sheet in roof tile applications.Must Comply with
applicable Roofing Application Standards and Building Codes.
Deck Type 1: Wood,Non-insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(3): Anchor sheet mechanically fastened to deck,membrane adhered.
Anchor Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4"headlap and a
6"end lap mechanically fastened to deck with approved nails and tin caps 6" o.c.at the side lap
edge and in a grid pattern spaced 12" o.c. in the field of the roll.
Membrane: One or more plies of Weather-Armor SB-1,or Weather-Armor HTI self-adhering membrane
adhered to the anchor sheet with a minimum 3"headlap and 6"end lap.
Surfacing: Shall be acceptable for use in approved asphaltic shingles,wood shakes,&shingles,quarry
slate,and metal roof applications.Must Comply with applicable Roofing Application Standards
and Building Codes.
Deck Type 1: Wood,Non-insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(4): Anchor sheet mechanically fastened to deck,membrane adhered.
Anchor Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4"headlap and a
6"end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap
edge and in a grid pattern spaced 12" o.c. in the field of the roll.
Membrane: One or more plies of Weather-Armor FTI self-adhering membrane adhered to the anchor sheet
with a minimum 3"headlap and 6"end lap.
Surfacing: Shall be acceptable for use in approved asphaltic shingles,wood shakes,&shingles,quarry
slate,metal roof,and mechanically fastened roof tile applications.Must Comply with applicable
Roofing Application Standards and Building Codes.
NOA: 17-0427.10
MIAMMDADE COUNTY Expiration Date: 03/28/18
Approval Date: 08/31/17
Page 4 of 5
LABELING:
All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,city,
state and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County
Product Control Seal as shown below.
MIAMI•DADE COUNTY
...•
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate
the installation of this material.
LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance
with applicable building code.
3. Weather-Armor SB-1, and Weather-Armor HT1 shall not be hot mopped; refer to manufacturer's published
literature for product compatibility.
4. Gardner Underlayments listed herein are components used in roof assemblies. Roof assemblies are approved
under specific assembly Notice of Acceptance.
5. APOC-Tuff Felt 26,United FGUR20,APOC-Tuff Felt 46,United FGUR10,United FGUR70,GatorSkin,
Weather Armor CX-L,and Weather-Armor SB-1 listed herein shall not be left exposed as a temporary roof
for longer than 30 days of application.
6. Weather-Armor HT and Weather-Armor FT1 listed herein shall not be left exposed as a temporary roof for
longer than 180 days of application.
7. Gardner Underlayments listed herein may be used with any approved roof covering Notice of Acceptance
listing Gardner Underlayments listed herein as a component part of an assembly in the Notice of Acceptance.
If Gardner Underlayments listed herein is not listed; a request may be made to the Authority Having
Jurisdiction (AHJ) or the Miami-Dade County Product Control Department for approval provided that
appropriate documentation is provided to detail compatibility of the products, wind uplift resistance,and fire
testing results.
8. For fire classification of specific roof assemblies using Gardner Underlayments listed herein refer to a
current Approved Roofing Materials Directory for fire ratings of this product.
9. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61 G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE