Loading...
HomeMy WebLinkAboutWind Load Calculation PARADISE EXTERIORS "Building Our Quality Reputation One Customer At A Time SCC131150472 Propeqy Information Building Information Owner: MARIANA GARCIA DE LOPEZ Wind Zone: 170 MPH. Address: 757 CYPRESS ST Exposure Category: C PORT ST LUCIE,FL 34952 Minimum Building Dimension: 25 ft. Mean Roof Height: 12 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number ZoneIF Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 23 42 7 37.8 -41.0 2 Int 52 37 7 37.1 -40.3 3 Int 71 79 7 34.5 -37.7 4 Int 52 36 7 37.2 40.4 5 Int 51 36 7 37.2 -40.4 6 Int 52 36 7 37.2 -40.4 7 Int 36 37 7 37.8 -41.0 8 Int 36 36 7 37.8 -41.0 9 Int 52 36 7 37.2 -40.4 10 Int 52 36 7 37.2 -40.4 11 Int 52 37 7 37.1 -40.3 12 Int 73 37 7 36.3 -39.5 13 Int 36 61 7 36.8 -40.0 14 Int 36 61 7 36.8 -40.0 _ ......._. ..... _ 15 Int 36 _ 61 __. 7 36.8 -40.0 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page I of 1 WNDOW& DOOR OPENING INFORMATION A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Comer Zone-1 D%of least horizontal dimension or 40%of the mean roof height,whichever is smaller, but not less than 4%of least horizontal dimension or 3 ft. OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING SHUTTERS NUMBER or Interior OR DOOR NUMBER (+) PSF (-)PSF (+)PSF (-)PSF DIMENSIONS MULLION REQ Y/N SIZE REQ Y/N/NA 1 Int window 7/8"Lami IG FL15780.8 55 65 37.8 -41.0 54 x 76.5 23x42 No No 2 Int window 7/8"LamilG FL15781.11 55 60 37.1 -40.3 73 x 63 5207 No No 3 Int Door I"Lami IG FL11103.1 60 60 34.5 -37.7 96 x 96 71x79 No No 4 Int window 7/8"LamilG FL15781.11 55 60 37.2 -40.4 73 x 63 5206 No No 5 Int window 7/8"LamilG FL15781.11 55 60 37.2 -40.4 1 73 x 63 5106 No No 6 Int window 7/8"Lam]IG FL15781.11 55 60 37.2 -40.4 73 x 63 52x36 No No 7 Int window 7/8"LamFL15780.8 55 65 37.8 -41.0 54 x 76.5 36x37 No No 8 Int window 7/8"LamFL15780.8 55 65 37.8 -41.0 54 x 76.5 3606 No No 9 Int window 78"LamilG FL15781.11 55 60 37.2 -40.4 73x63 5206 No No 10 Int window 7/8"LamilG FL15781.11 55 60 37.2 -40.4 73x63 5206 No No 11 Int window 7/8"LamilG FL15781.11 55 60 37.1 -40.3 1 73 x 63 5207 No No 12 Int window 7/8"LamilG FL15781.11 55 60 36.3 -39.5 73 x 63 7307 No No 13 Int window 7/8"`-ami IG FL15780.8 55 65 36.8 -40.0 54 x 76.5 36x61 YES No 14 Int window 7/8"Lami IG FL15780.8 55 65 36.8 -40.0 54 x 76.5 36x61 YES No 15 Int window 7/8"Lami 16 FL15780.8 55 65 36.8 -40.0 54 x 76.5 36x61 YES No