HomeMy WebLinkAboutProduct Approval y � i r BC(S Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links Search dbpr Product Approval USER:Public User Product Approval Menu>Product or Application Search>Ap cation 1st>Application FL# FL5444-R13 Application Type Revision Code Version 2017 Application Status Pending FBC Appr Comments LE COPY Archived Product Manufacturer CertainTeed Corporation-Roofing Address/Phone/Email 20 Moores Road Malvern, PA 19355 (610)893-5400 mark.d.harner@saint-gobain.com Authorized Signature Mark Harper mark.d.harner@saint-gobain.com Technical Representative Mark D. Harner Address/Phone/Email 18 Moores Road Malvern, PA 19355 (610) 651-5847 Mark.D.Harner@saint-gobain.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 03/09/2020 Validated By John W. Knezevich, PE J Validation Checklist- Hardcopy Received Certificate of Independence FL5444_R13_C0I_2018._01_C0INIEMINEN,pdf Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2011 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 01/24/2018 Date Validated 01/29/2018 Date Pending FBC Approval 01/30/2018 Summary of Products FL# Model,Number or Name Description 1- 5444.1 CertainTeed Asphalt Roof Shingles 3-tab,4-tab,strip(no-cut-outs), laminated and architectural asphalt roof shingles Limits of Use Installation Instructions Approved for use in HVHZ: No FL5444_&U_u_2=_QL_INAL_EB_CERTAINTEED ASPHALT Approved for use outside HVHZ:Yes SHTNGLE5_FL5444-R13.pd Impact Resistant: N/A Verified By: Robert Nieminen, PE PE-59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER Section 5 for Limits of Use Evaluation Reports I FL5444_gj _8E_�Q�$_ FINAL_FU_GERTAINTEED_ASPHALT (SHING E _FL5444-R13.pjff i ! Created by Independent Third Party: Yes Contact us::2601 Blair stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Cggyjjght 2007-2013 State of Florida.::Privacy Statement::Accessibility.Statement::Refund statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395. `Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emaiis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S., please click here. Product Approval Accepts: ® MCI Credit Card Sate Business & Professional Regulationl � T w R BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FOC Staff SCIS Site Map Unks Search C Product Approval pr USER:Public User Product Approval Menu>Product or Appbcation Search>Application Lis[>Apphcat:on Detail>Application Checklist Form Title: Validation checklist for evaluation report from an architect or engineer Form #: 9N-3.011(3)(c) Administrative Validation 1. Verify the evaluator is a Florida Registered Architect or Florida Professional Engineer who has taken the core building code course. 2. Verify submission of the evaluator's certification of Independence. 3. If the evaluation Is not performed by a third party independent of the manufacturer then verify validator's certificate of independence. 4. Verify the evaluation report is for the products listed on the application as described on the application and that the products are within the scope of Rule 9B-72. 5. Verify that test reports demonstrating compliance were performed at a test lab accredited by an approved accreditation body for the test performed,and verify test lab location. 6. Verify that the test reports or rational analysis are required by the Building Code as a component of a product approval for the product category and subcategory. 7. Verify that rational analysis demonstrating performance were executed utilizing current code requirements and was not used in lieu of a standardized test required by the Code or that rational analysis was not required. 8. Verify that all data,test reports and calculations,are substantiated on the report. 9. Verify that the application has the Code sections and reference standards for which the evaluation demonstrates compliance. 10. Verify the method of demonstrating compliance indicate any limitations on the use of the product,as intended. 11. Verify the manufacturer installation instructions are in accordance with the evaluation report,and attachments are provided. 12. Verify that a quality assurance program audited by a Florida Building Commission approved third party quality assurance agency is in place. To the best of my/our knowledge,this application is complete,the items in the checklist above have been verified and reviewed, and the evaluation report submitted with this application indicates that the product, method,or system described in this application meets or exceeds the Florida Building Code requirements and reference standards listed in the application. Contact Us;:2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyri ght 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click here. NEMO I Etc. Certificate of Authorization#31455 353 Christian Street, Unit#13 Oxford,CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY EVALUATION REPORT CertainTeed Corporation Evaluation Report 3532.09.05-1114 20 Moores Road FL5444-1113 Malvern, PA 19355 Date of Issuance:09/22/2005 (610)651-5847 Revision 14:01/24/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition(2017)Florida Building Code sections noted herein. DESCRIPTION: CertainTeed Asphalt Roof Shingles. LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMOJetc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOJetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 13. Prepared by: Robertl.M.Nieminen,P.E. ' Florida Registration No.59166,Florida DCA ANE1983 Ct>'.F. Q Com: The facsimile seal appearing was authorized by Robert iF ''•�,✓/;;,�a�O�,,Q:� Nieminen,P.E.on 01/24/2018. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMOIetc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO I etc.is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMOIetc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. ONEMOletc. ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: CertainTeed Asphalt Roof Shingles, as produced by CertainTeed Corporation, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code and 6th Edition (2017) Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: Entity Examination Reference Date UL(TST 1740) ASTM D3161 94NK9632 05/15/1998 UL(TST 1740) ASTM D3161 99NK26506 11/23/1999 UL(TST 1740) ASTM D3161 03CA12702 05/27/2003 UL(TST 1740) ASTM D3161 03CA12702 06/16/2003 UL(TST 1740) ASTM D3161 03NK29847 10/03/2003 UL(TST 1740) ASTM D3161 04CA11329 05/24/2004 UL(TST 1740) ASTM D3161 04CA32986 12/03/2004 UL(TST 1740) ASTM D3161 05NK07049 04/15/2005 UL(TST 1740) ASTM D3161 05NK16778 05/12/2005 UL(TST 1740) ASTM D3161 05CA16778 05/12/2005 UL(TST 1740) ASTM D3161 05NK14836 05/22/2005 UL(TST 1740) ASTM D3161 05NK22800 06/22/2005 UL(TST 1740) ASTM D3462 R684 09/21/2005 UL(TST 1740) ASTM D71S8 05NK08037 06/28/2006 UL(TST 1740) ASTM D3161&D3462 09CA28873 07/23/2009 UL(TST 1740) ASTM D3462 IOCA41303 10/07/2010 UL(TST 1740) ASTM D3161 IOCA41303 10/08/2010 UL(TST 1740) ASTM D7158 10CA41303 10/27/2010 UL(TST 1740) ASTM D3161&D3462 10CA44960 11/11/2010 ULLLC(TST 9628) ASTM D3161,D3462&D7158 13CA32897 11/21/2013 UL LLC(TST 9628) ASTM D3161,D3462 TFWZ.R684 04/22/2014 UL LLC(TST 9628) ASTM D7158 TGAH.R684 04/22/2014 ULLLC(TST 9628) ASTM D3161&D3462 4786334434 09/16/2014 UL LLC(TST 9628) ASTM D3161&D3462 4786570826 02/12/2015 UL LLC(TST 9628) ASTM D3161,D3462&D71S8 4786570717 12/16/2015 UL LLC(TST 9628) ASTM D3161&D3462 478719S678 02/09/2016 ULLLC(TST 9628) ASTM D3161,D3462&D7158 4787380356 10/26/2016 ULLLC(TST 9628) ASTM D3462 4787380357 10/13/2016 ULLLC(TST 9628) ASTM D7158 4787380357 11/08/2016 ULLLC(TST 9628) ASTM D3161 4787380357 11/09/2016 UL LLC(TST 9628) ASTM D3161,D3462&D7158 4787586427 01/25/2017 ULLLC(TST 9628) ASTM D3161&D3462 4788042412 11/15/2017 UL LLC(QUA 9625) Quality Control Service Confirmation Exp.03/09/2020 NEMO ETC,LLC Evaluation Report 3532.09.05-R34 Certificate ojAuthorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R13 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018 Page 2 of 13 ONEMOJetc. 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 CT20—,XT-25,XT'"30 and XT'"30 IR are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Arcadia•", Belmont®, Belmont® IR, Carriage House Shangle®, Grand Manor Shangle®, Landmark', Landmark' IR, Landmark•" Pro, LandmarkTM Premium, Landmark— TL, Landmark' Solaris and Landmark'"Solaris IR are fiberglass reinforced,laminated asphalt roof shingles. 4.1.3 NorthGate'"'is a fiberglass reinforced,laminated,SBS modified bitumen roof shingle. 4.1.4 Presidential Shake'", Presidential Shake'" IR, Presidential Shake TLTM and Presidential Solaris— are fiberglass reinforced,architectural asphalt roof shingles. 4.1.5 Hatteras'"',Highland SlateTM and Highland Slate""IR are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.6 Patriot— is a fiberglass reinforced asphalt roof strip-shingle (with no cut-outs) providing a laminated appearance through an intermittent shadow line with contrasting blend drops for color definition. 4.2 Hip&Ridge Shingles: 4.2.1 Presidential Accessory, Accessory for Hatteras, Shangle Ridge TM, Shadow Ridge'", Cedar Crest'", Cedar Crest— IR, NorthGate Ridge and NorthGate Accessory are fiberglass reinforced accessory shingles for hip and ridge installation. 4.3 Accessory Starter Strips: 4.3.1 SwiftStart®Starter Shingle is a starter strip for asphalt roof shingles. Its overall size of 15-1/4" x 38-3/4" yields two(2)7-5/8"x 38-3/4"starter pieces per shingle. 4.4 Any of the above listed shingles may be produced in AR(algae resistant)versions. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMOIetc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use within FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 All shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable for us in all wind zones UP to Vasd = 150 mph (Vit = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 Presidential Accessory, Accessory for Hatteras, Shangle Ridge, Shadow Ridge, Cedar Crest, NorthGate Ridge and NorthGate Accessory hip & ridge shingles have been evaluated in accordance with ASTM D3161,Class F. All except NorthGate Ridge and NorthGate Accessory require use of BASF Sonolastic NP 1 adhesive or Henkel PL® Polyurethane Roof & Flashing Sealant, applied as specified in manufacturer's application instructions, for use in wind zones up to Vasa=150 mph (Vit=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 SwiftStart®Starter Shingle has been evaluated in accordance with ASTM D3161,Class F. Refer to Section 6 for installation requirements to meet this wind rating. 5.4.4 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. NEMO ETC,LLC Evaluation Report 3532.09.05-1114 Certificate of Authorization#31455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R13 CertainTeed Asphalt Roof Shingles;(610)6S3-5847 Revision 14:01/24/2018 Page 3 of 13 ONEMOletc. 5.4.4.1 Analysis in accordance with ASTM D7158 indicates the measured uplift resistance(RT)for the CertainTeed asphalt Roof shingles listed in Section 4.1 through 4.6(except Presidential Solaris')exceeds the calculated uplift force (FT) at a maximum design wind speed Of Vasd = 150 mph (Vast = 194 mph) for residential buildings located in Exposure D conditions with no topographical variations (flat terrain) having a mean roof height less than or equal to 60 feet. The shingles are permissible under Code for installation in these conditions using the installation procedures detailed in this Evaluation Report and CertainTeed minimum requirements, subject to minimum codified fastening requirements established within any local jurisdiction,which shall take precedence. 5.5 All products in the roof assembly shall have quality assurance audits in accordance with FAC Rule 61G20-3. 6. INSTALLATION: 6.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.1 Underlayment shall be acceptable to CertainTeed Corporation and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 611320-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Installation of asphalt shingles shall comply with the CertainTeed Corporation current published instructions, using minimum four(4) nails per shingle in accordance with FBC 1507.2.7 or Section R905.2.6 and the minimum requirements herein. 6.2.1 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.2 Where the roof slope exceeds 21 units vertical in 12 units horizontal, use the"Steep Slope"directions. 6.3 CertainTeed asphalt shingles are acceptable for use in reroof(tear-off)or recover applications,subject to the limitations set forth in FBC Section 1511 or R908 and CertainTeed published installation instructions. 6.4 SWIFTSTARTO STARTER SHINGLE: Fastening: Use four nails, located as shown below 38-3/4"(984 mm) t 1'(25 mm)from edge 1' (25 mm)from edge —�-I 7-5/8' (194 mm) Max 3" (76 mm) 1 The inner two fasteners must be placed such that they fall at least 3'(76 mm)from the end joints of the shingle in the succeeding course. NEMO ETC,LLC Evaluation Report 3532.09.05-1114 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-1113 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018 Page 4 of 13 ONEMOjetc. LOW AND STANDARD SLOPE STEEP SLOPE ENGLISH 12" 12" 12" Use four nails and six spots of asphalt roofing cement'for every full (305 nm) +-(305 mm)--(305 mm)—, shingle(Figure 11-4).Asphalt roofing cement meeting ASTM D4586 1"(25 mm) Sealant 1"(25 mm) Type 11 Is suggested. --- -I- -- 5 5/s"(145 mm) 5!/z"for Abrwod - -T--_ -_ ---- plaar T T ) _ - METRK `., 131/8" 131/8" �.- 13118" -.{ RoofingCement 11 Y 1"(25 mm) Sealant 1"(25 mm) Apply 1"(25 mm)spots of asphalt roofing cement --- - -- -- under each tab corner. 1 Figure 11-1:Use-four nails turd sir spots ofaspW cement on strip slopes *CAUTION:Excessive use of roofing cement can cause shingles to blister, Figure 11-3:Use four nails for m*?ry fuU sbingle. 6.5.1 Hip&Ridge for CT�2(0-,XT-25,XT-30,XTT""30 IR: Cut Shingles 1 It I �2"(50mm) -Remover (25 mn)U l! )f i 5 12"(305 mm) gsom li- - (125 mm) Gap Cap Cap 305 mm) �� �ivtnas Shingle Shingle Shingle rte�\ stoo\\ Figure 11-24:Cul talo,Men frim back to make cap sbhrgtas ��5 R��`o`No poa Q��`l (f,ngllsb dime nstrms sbou n). Figure Il-25:Installation of caps along the bibs and r4as. 6.5.1.1 For ASTM D3161, Class F performance use BASF "Sonolastic® NP11" adhesive or Henkel "PL® Polyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements. 6.6 ARCADIATm: LOW AND STANDARD SLOPE STEEP SLOPE Use SIX nails for every full shingle located ac shown below. Use SIX nails and FOUR spas of asphalt roofing cement for every full shingle as shown below.Apply asphalt roofing cement I"(25 mm) from edge of shingle.Asphalt roofing cement meeting ASTM D 4586 Type 11 is suggested. f 1'(25 mm) 1'(25 mm) Ntil Lirre Nail Nail lige fl'(25 mm) 1'(25mm)— Figure 2:Use sly nallc for every full sbingle. `' =o , Figure.j.tise sir nails and four spots of asl)ball rywfing cement on stomp sh#wv. NEMO ETC,LLC Evaluation Report 3532.09.05-R14 Certificate of Authorization X31455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-1113 CertainTeed Asphalt Roof Shingles;(610)651-S847 Revision 14:01/24/2018 Page 5 of 13 ONEIVIOletc. 6.6.1 Hip&Ridge for Arcadia^": Cedar Crest—,Cedar Crest" IR Use two (2), minimum 1%-inch long fasteners per shingle. For the starter shingle, place fastener 1-inch from each side edge and about 2-inch up from the starter shingle's exposed butt edge,ensuring minimum %-inch embedment into the deck,or full penetration through the deck. For each full Cedar Crest shingle, place fasteners 8-5/8-inch up from its exposed butt edge and 1-inch from each side edge. For ASTM D3161,Class F performance use BASF"Sonolastic®NP11"adhesive or Henkel "PL® Polyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements,to hand-seal Cedar Crest shingles. Apply NP 1 or PL adhesive from the middle of the shingle's raised overlay on the top piece and extending approximately 4-inch along the sides of the headlap along a line%to 1-inch from each side of the shingle's headlap. Immediately align and apply the overlying shingle,gently pressing tab sides into the adhesive,and install nails. To secure the other side,apply a 1-inch diameter spot of NP 1 or PL adhesive between the shingle layers. Hand-sealing adhesive 12' r—'I 1/4" t— 4" 20 gam' re AIS (305 r" IM re f r �1Smn` 3/4" 1" Dab of asphalt cement between 1" shingle layers 6.7 • OR • Low and Standard Slope Steep Slope(greater than 21:12): (2:12 to 21:12): Use SEVEN nails and EIGHT spots of Use FIVE nails for every full Belmont shingle, asphalt roofing cement"'for every full located as shown below. Belmont shingle.Apply asphalt roofing cement 1"(25mm)from edge of shingle. "'ork33( ' a See below.Asphalt roofing cement meeting u Vzmm)—I .� ASTM D4586 Type II is suggested. 5ot'(16mm) 8W* t 12-(36tnm) U L of I= o Additional nails it tequned + I�t'(25 mm) 1•(25mn)--_1 �— 5/B'(16 ren) (220 rind I't15 mm -------Hoofing Cement--- NEMO ETC,LLC Evaluation Report 3532.09.05-R14 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVH2 EVALUATION FL5444-R13 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018 Page 6 of 13 ONEIVIOletc. 6.7.1 Hip&Ridge for Belmont®or Belmont®IR: 6.7.1.1 Option 1: For Belmont,refer to instructions herein for Cedar CrestTM or Cedar Crest"'IR hip and ridge shingles. For Belmont®IR,refer to instructions herein for Cedar Crestm IR hip and ridge shingles. 6.7.1.2 Option 2: For Belmont: Shangle°Ridge 18, Remove tape t-12. Exposure from the right side g• and fasten SECOND Fasten the f' 11X left side RIGHT FIRST Remove F85/& This Tape LEFT Figure 17-19:Dlsiallalion of Shangle®Ridge shingles Figure 17-18.-Shangle'Ridge. ori hips and ridges. 6.7.1.3 For ASTM D3161,Class F performance use BASF"Sonolastic®NP1`adhesive or Henkel "PL® Polyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements. HOUSE6.8 CARRIAGE ►GRAND MANOR LOW AND STEEP SLOPE STANDARD SLOPE Cse seven nails and three spots of asphalt roofing cement for every full Grand Manor Shangle.Use five nails and three spots of asphalt I se lire nails for ewes full Shangle. roofing cement for even full Carriage[louse Shangle and Centennial Slate.Apply asphalt roofing cement i'(25 mm)front edge of shingle (Figure 17.5).Asphalt roofing cement meeting A.1"f,N U45861\pe II V 1., is suggested. 1-.—(25 tarn) � (25 mm) 11/2" 5 JIB- (38 mm) (16 mm) (220 mm) " of less 1.. L�(25 1mm) Figure 17-4:Use fire nits for eh wry fullC;rand Afanor Sbangle. 5F8 8518" Carriage/louse Shangle,or Centennial.Siale. (16MI l (220 mm) 25 mmiT Rooting Cement Figure 17-5:tF'ben inrlalling Grand.1h u n-.h nxl^on sleep.slapes. use serer nails and three spots ofaspiedl roofing mien!. 6.8.1 Hip&Ridge for Carriage House Shangle®and Grand Manor Shangle:Refer to instructions herein for Shangle•Ridge hip and ridge shingles NEMO ETC,LLC Evaluation Report 3S32.09.0S-R14 Certificate of Authorization#32455 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FLS444-R13 CertainTeed Asphalt Roof Shingles;(610)6S3-5847 Revision 14:01/24/2018 Page 7 of 13 NNEMOjetc. 6.9 LANDMARK'", LANDMARK- IR, LANDMARKM PRO, LANDMARKTM PREMIUM, LANDMARK- LOW AND STANDARD SLOPE LANDMARK TL 13V 13" 1342" METRIC DIMENSIONS (343mm)- (330mm)—+(343mm)-+{ 2 143/4" 12" I+-1"(25 mm) 1"(25 mm)—I •- �- {305 min)-*-�-(375 mm)-��-(305 mm)-►j 1"(25 min) Releaser Tape V(25 mm)�I 1'/t Na lablc Area Figure 13.4:use four mails for em)-fill shingle. NorthGate: wu>E N IING tY 141'4' 1T AREA (305 mm) 375 mm) �j r (305 mm)–►I Nailrg Limb 1'±25 mm) Upwnalk* V(25 mm)— /140"r na4ln$ AE 71 77 Nailing areas for low and standard*pes(from 2:12 to 2112) Nal 5af6een upper R kwre•Ves as s!+oan abom STEEP SLOPE L'se six nails and four spots of asphalt roofing cement for every full LANDMARK TL Laminated shingle.See below.Asphalt roofing cement should sleet ASTM D4586ly a N.Apply r spots of asphalt roofing cement undo �•-131/z" each corner anti at about 12"to 13"in from each edge. (343 mm) 71 30 mm) (343 mm) METRIC DIMENSIONS 1125 mm) 1"(25mm)� I I x-12" 143/4" - ---12" (305 mm) (375 mm) (3D5 mm) --- 1" (25 mm) - (25 mm) vam ay..r..xu tizxax#r .ma urr cnxr cs:r:: Roding Cef oro 1"(25 mm) Rel pe 1'•(25 mm)- 1 Nail Area For Sleep Figure 13.5:Use six nails and four spots of 1"—►�I+ +i" asphalt—fingcmnent on steep Dopes (25 mm) ---- (25 mm; Roofing Cement NEMO ETC,LLC Evaluation Report 3532.09.05-R14 Certf7cateofAuthorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FLS444-R13 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018 Page 8 of 13 ONEMOjetc. NorthGate: STEEP 12" 14-3/4• 12' SLOPE Ir--(305 mm)— (375 mm -,,-4305 rnrn +-j NAILING iNailinmils AREA l X1"(25 mm) betwee% �wis 1'(25 mm)� �- na1 mes. { 7 A7 • ----` # 0o rng-Cement Nailing areas for steep slopes(greater than 21:12) and"Storm-Naiiing" Nail between lower 2 nail lines as shown above. 6.9.1 Hip&Ridge for Landmark'",Landmark""IR,Landmark'Pro,Landmark'"Premium,LandmarkTM TL, Landmark-Solaris,Landmark'"Solaris IR,NorthGate: 6.9.1.1 Option 1: Shadow Ridge'"or NothGate Accessory 12" 97/8' (305mm) 415/16(250mm)415/16 66" (125mm) I (125mm) (150mm) (150mm) Notch for Notoh for R Centering Centering 12" �� (305mm) \Notches for Alignment to (337mm) Notches for Alignment to 75/8" the Top Edge of the Previous (180mm) the Top Edge of the Previous (196mm) Cap for 5"(125mm)Exposure Captor55/6'(141mm)Exposure English Dimension Metric Dimension Shadow Ridge— Shadow Ridge- 9 27,22' (250 mm) 415/'16'(125 mm) 131/8" f {333 mm)—► Centering Notch 6 5/8-01"6/8'► _ (168 mm)I/1 188 mm 13 1A' J T (337 rnm) Align these / 1 Centering _ rotches to top 7 13 1/4' edge ai (19l�) (337 mm) e / p evdg ca�rse Align these 7 5/8" notches to top (194 mm) edge of 1 previous course. NorthGate Ridge NorthGate Accessory NEMO ETC,LLC Evaluation Report 3532.09.05-R14 Certificate of Authorization X32455 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R13 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018 Page 9 of 13 ONEIVIOletc. 12" (3051nn') /Laying Notch I 5"(125mm) I E>Posure Figure 13-2o.•use laying notcbes to center sbingks on bips and ridges,and to locate the correct exposure. 6.9.1.2 For ASTM D3161, Class F performance use BASF "Sonolastic• NP11" adhesive or Henkel "PL® Polyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements. 6.9.1.3 Option 2: Refer to instructions herein for Cedar CrestTM,Cedar Crest'IR hip and ridge shingles. 6.10 PRESIDENTIAL SHAKET ,PRESIDENTIAL SHAKE—IR,PRESIDENTIAL SHAKE T1.7m,PRESIDENTIAL • LOW AND STANDARD SLOPE: STEEP SLOPE: For low and standard slopes,use five nails for each full Presidential For steep slopes,use nine nails for each full Presidential shingle and shingle as shown below. apply 1'diameter spots of asphalt roofing cement under each shingle tab. After applying 5 nails In between the nailing guide lines,apply 4 nails t' Nailing 40"-moi above tab cutouts making certain tabs of overlying shingle cover nails. Guide Lines (1016 mm) 51/4 —� (133 min) • • • • • 141/4" 1 1/2' 38 mm) (36�mm) ' ' •— ' — ' } —r -- y- - —•- - — � i 1.. T NOTE:Apply nails on painted guideline. Figure 16-6.•Fastening Presidential and Presidential TL Stake V diameter asphalt roofing cement sbingles on low and standard slopes Figure 16-7:Fastening Presidential and Pliriskkmtint TIL Sbake sbingles on steep scopes. 6.10.1 Hip&Ridge for Presidential Shake',Presidential Shake'IR,Presidential Shake TLI,Presidential Solarisl: 6.10.1.1 Option 1: Presidential Accessory PRESIDENTIAL ACCESSORY Presidential accessory shingles can be used for covering hips and ridges.Apply shingles up to the ridge (expose no more than 7'from the bottom edge of the"tooth."Fasten each accessory with two fas- teners.The fasteners must be 13/4' long or longer,so they penetrate either 3/4' Into the deck or completely through the deck.Presidential accessory comes in two different sizes:Accessory produced in Birmingham,AL Is 12'x 12';Portland,OR produces 97/8' x 131/4' accessory. 6.10.1.2 For ASTM D3161, Class F performance use BASF "Sonolastice NP1' " adhesive or Henkel "PL® Polyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements. NEMO ETC,LLC Evaluation Report 3532.09.05-R34 Certificate ofAuthorizotion#31455 6T"EDITION(2017)FBC NON-HVH2 EVALUATION FL5444-R13 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018 Page 10 of 13 ONEMOjetc. 6.10.1.3 Option 2:Refer to instructions herein for Cedar Crest'",Cedar Crest'IR hip and ridge shingles. 6.11 HATTERAS"": LOW,STANDARD AND STEEP SLOPE: 1- -(2,0'."M) 9 _g -q I (2a0 mm) i2 0 mm) (230 mir) (230 nm) I I (230 mm) 1.231)mm) (230 mm) (230 mm) I 1 t x(25 mm) _ _ mm)= x(25 mm) (25 m_)-1 240 mm) 93(8 ----- Roofing Cement_ (240 mm) __� flgnrr/5 1:faslrvung/!aIle+ns.lhuieMi nn,Veep.Vapex For steep slopes.use fine nails and eight sluts of asphalt roofing Figure 15.3:lasleeiug 11a11eras A'hiuL4es on csmtent for each hill UJUM s shingle as sham abae..y)ply I- Lon and Slandard.Vopri (25mm)diameter spas of routing cemrm(ASTM 0 9586 Ttpe II For low and siamdard slopes,use Gee nails for each full suggested)antler each iab corner.Press shingle into place,(lo no( I Iaucrts shingle as shown aboic. (%pose cement. CAUTION:Too much roofing cement can cause shingles to blister. 6.11.1 Hip&Ridge for Hatteras'"': 6.11.1.1 Option 1: Accessory for Hatteras Fasten both sides i i i I 1 2 3 Figure 15-14.•18 tbrelepiece units separate to make 54 Hatteras Amessory sbingles. 6.11.1.2 Option 2: Cut Hatteras Shingles —91,— (230 mm) I I s'te� 8' 18"(460 mm) Fgoti\ (203 mm) a`25mc�1 -- - ----- -- 460 mm) .� Ca Sh ogle Shingle ShCingle Shingle Figure 15-20:Cut Hatteras sbinghs to make coder cap. Figure 15-21:Installation of Caps along baps and ridges, 6.11.1.3 For ASTM D3161, Class F performance use BASF "Sonolastic® NP1` adhesive or Henkel "PL®Polyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements. NEMO ETC,LLC Evaluation Report 3532.09.05-R34 Certificate ojAuthorization#31455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R13 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018 Page 11 of 13 ONEMOjetc. 6.12 HIGHLAND SLATE TIA.HIGHLAND SLATE—IR: LOW AND STANDARD SLOPE: STEEP SLOPE: _ Use FIVE nails and EIGEIT spots of asphalt roofing cement*for each Qaon«ro use. i�am wo.o full Highland Slate shingle.For Wand-Dade,SIX nails are required. Apply t'diameter spots of asphalt roofing cement under each tab corner.Asphalt roofing cement meeting ASTM D4586 Type N is suggested. 1- 1. 124^rt QStmm) eCmerd Miemi-Dadereqs" SIX nate(Mo refs 1'(M mm)in'Wisdevercenter Noee wmn). I MiemfDeM regwee S1Xneils(Mnneat1•pSmmji�raedatoulmatwvm} -- Roofing Figure 11-3:Use FI)W nails for�'tNgbland f7ate sbtngle. Figure 11-3+Use R E naiO and etgbt spots ofaspbalt rao,Jtnf emm nt ander eacb tab cornet "CAUTION:Excessive use of roofing cement can cause shingles to blister. 6.12.1 Hip&Ridge for Highland Slate'',Highland Slate—IR:Refer to instructions herein for Cedar CrestTM,Cedar CrestTM'IR or Shangle Ridge'"'hip and ridge shingles. 6.13 PATRIOT—: LOW AND STANDARD SLOPE STEEP SLOPE Use FOUR nails for every full shingle looted as shown below. lw POUR nails and tour s)x.>ts of asphalt roofing cement for every hull shingle as shown below.Asphalt roofing cement meeting ASTM D458.6 Type II is sugRested.Apply 1'(25 mm)spots of asphalt roofing Sealant cement as shown. CAU"ITON:Excessive use of roofing cement can ctuse shingles to blister. t•(25 inns (156 ten) I 1 T (mtmnl t m3 m) — ————— —— ti-t!8't"i•(15 mmj 1'a5 aeo't—� 1156 mm)t� T _ = M 12-19 13-IN 124C 6.13.1 Hip & Ridge for Patriot': Refento instructions herein for Cedar Crest"", Cedar Crest'"' IR, Shadow Ridge'", NorthGate or Shangle Ridge'"hip and ridge shingles. 7. LABELING: 7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. NEMO ETC,LLC Evaluation Report 3532.09.05-R14 CertecateofAuthoriration#32455 6r"EDITION(2017)FBC NON-HVHZ EVALUATION F15444-1113 CertainTeed Asphalt Roof Shingles;(610)6S1-5847 Revision 14:01/24/2018 Page 12 of 13