Loading...
HomeMy WebLinkAboutProduct specificationH The now degree of comfort:' Professional Classic'"' Specifications Residential Electric .` Water professional Classic Water Heaters DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO. GAL MODEL TYPE CAP. NUMBER FIRST HOUR RATING G.P H. RECOVERY IN O.P.H. 9V F RISE TANK HEI HEIGHT A HEGHTTO WATER CONN. a DIAMETER C APPROX. SHIP WT. (LBS) ENERGY FACTOR Tag 30 PROE30 T2 RH95t 48 21 47-1/2 50-3/8 19-1/4 92 0.95 57 21 60-3/4 63-5/8 19-1/4 109 0.95 Tall 50 PROE50 T2 R1-11951 6721 58-5/8 61-5/8 20-1/4 121 0.95 Tall 55 PROE55 T2 RH94' 71 21 57 59-3/4 22-1/4 128 0.94 Med. 30 PROE30 M2 RH95t 44 21 37-1/2 40-1/2 20-1/4 92 0.95 Mod. 40 PROE40 M2 RH951 55 21 48-1/4 50-1/2 20-1/4 106 1 0.95 Med, 50 PROE50 M2 RH95' 65 21 50-1/2 23 132 0.95 Short 19.9 PROE20 S2 PH - 21 31-1/2 17 62 - Short28 PROE28 S2 RH95 42 21 31-1/8 23 95 0.95 Short 30 PROE30 S2 RH95 B" 42 21 P31-1/2 32 19-3/4 95 0.95 Short 36 PROE36 S2 RH95 45 21 33 24-1/4 118 0.95 Short 38 PROE38 S2 RH95 B" 55 21 32-5/8 23 108 0.95 Short 47 PROE47 S2 RH95 B" 55 21 32 34 26-1/4 149 0.95 Energy Factor based on D.O.E. (Department of Energy) test procedures. t System Sentinel optional. Add EC1 to the end of the model number. System Sentinel not available on single element models, available on dual element models only. System Sentinel not available in excess of 5 kW on 208 V models. - Water heater dimensions prior to installing insulation blanket that is included with water heater. • hieaters furnished with standard 240 volt AC, single phase non -simultaneous wiring, and 4500 watt upper and lower heating elements. • If heating elements of different wattages than those shown are demanded by zone requirements, they must be specifically requested. • Single element models available on special order (6000W max.). Substitute "1" for'2" in model number. • Special Wiring Options - A limited nurnber of special wiring options are available. Consult factory for price and availability. • All models equipped with heat traps. Recovery = wattage/2.42 x temp. rise `F. Example: 450OW = 21 GPI i 2.42 x 90° Recovery calculations used are based on 4500 vratt elements used in non-simuftaneous operation. 8" HOT O WATER COLD CONNECTION WATER RELIEF VALVE CONNECT] CONNECTION ANODE ROD DIAMETER A U B WATER CONNECTIONS ALL 3/4" N.P.T. in keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Water Heating • 101 Bell Road Montgomery, Alabama 36117-4305 • www.rheem.com PRINTED IN U.S.A. WAS WP FORM NO. PRIDE RH N Rov. 2