t e `ra ( f.product Approval
�y�-t �USER:Public User
0. -=
UU Product Approval Menu>Product or AUoltcation Seams>ApCi ntlonList>Application Detail
zf FL# FL2569-R13 1
Application Type Revision
Code Version 2017
Application Status Approved I I
a �
Comments
Archived —:
I •
Product Manufacturer Soprema,Inc. (Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville, NON-.US 00000
(819)478-2400
memathieu@soprema.ca
i
Authorized Signature Marc-Etienne Mathieu
memathieu@soprema.ca
Technical Representative Marc-Etienne Mathieu I
Address/Phone/Email 1688 Jean-Berchmans-Mlchaud I
Drummondville,NON-US 00000 i
(819)478-2400 Ext 3327
memathieu@soprema.ca
Quality Assurance Representative Jean-Francois Cote,Ph.D.
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca '
II
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
J
Florida Engineer or Architect Name who developed Robert J. M. Nleminen
the Evaluation Report
Florida License PE-59166 j
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 07/18/2020 I.I
Validated By John W. Knezevich,PE 1
• Validation Checklist- Hardcopy,Receivedl
I ti '
Certificate of Independence FL2569 R13 COI 2017 9-LCOI Niemine p f
Referenced Standard and Year(of Standard) Standard ' Year
ASTM D1970 I 2015
ASTM D6163 2008
FM 4474 ? I 2011
FRSA/TRI April 2012(04-12) i 2012
TAS 110 j 2000
UL 1897 2012
, I
I
http://ww-w.floridabuilding.org/pr/pi_app_dtl.aspx?param=WGEVXQrg,,;k,OFEfi ckB 10... 1/10/2018
Florida Building Code Online Page 2 of 2
Equivalence of Product Standards I
Certified By j
Sections from the Code I
I
Product Approval Method Method 1 Option D +
I
Date Submitted 10/09/2017
Date Validated 10/11/2017
I +
Date Pending FBC Approval 10/15/2017
Date Approved 12/12/2017
i
Summa of Products
FL# Model,Number or Description i
Name j
2569.1 soprema Roof Self adhering roof underlayments B
Underlayments l
Limits of Use Installation Instructions ii 9I
Approved for use in HVH2:No F12569�R13I 2017 10TFINAL ER�I SOPTRE�A_CA UiVDERLAYMENTS FL2569
Approved for use outside HVHZ:Yes R13.Ddf iI
Impact Resistant:N/A Verified By: Robert Nieminen,P.E. PE-59166
Design Pressure:+N%A/-150 Created by Independent Third Party Yes
Other: 1.)Refer to ER Section 5 for Evaluation Reports
Limits of Use.2.)The design pressure FL2569 'R13 AE 2017 10 FINAL ER SOPREMA CA UNDERLAYMENTS &Z5_69-
noted herein pertains to underlayment R13.pdf
systems used beneath adhesive-set tile Created by Independent Third Partyll Yes
systems.Refer to ER Section 5.6.4 for
details.
I.I
Bactc Next '� -
I
I I
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
I ' )
The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statejjment::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in responseto a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.`Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must-provide the DEpartment with-an email address if
they have one.The emalls provided maybe used for official communication with the licensee.However emall addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the�public.To determine if you are a licensee under
Chapter 455,F.S.,please click here. +
Product Approval Accepts
1
Credit Card
Safe
I
I � I
i
r']
I
1
I
I
I i
i
I
I i
I 1
, I
http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsKIQFEric1cB 10... 1/10/2018
i ,
I �
. I
E)(TERIOR RESEARCH&DESIGN,LLC.
Y - ;Certificate of Authorization#9503
353,CHRISTIAN STREET,UNIT#13
ERD ; 3 OXFORD,CT 06478
(203)262-9245
EVALUATION REPORT
Soprema, Inc. Evaluation Report S18010.06.09-1311
1640 rue Haggerty
jlssuance:06/15/2009FL2569-R13
Drummondville,QuebecJ2C 5P8 Canada Date of
(819)478-2400 R vision 11:10/06/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida-Building Code, Residential Volume. ,The
products described herein have been evaluated for compliance with the 6 Edition ( 017) 'Florida Building Code
sections noted herein.
DESCRIPTION: Soprema Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the nam I d produ'ct(s) changes,the referenced
9
Quality Assurance documentation changes,or provisions of the Code that relate to the product(change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this
Evaluation Report relative to updated Code-requirements with each Code Cycle.1 11 1
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinityli ERD Evaluated
" may be displayed in
advertising literature. if any portion of the Evaluation Report is displayed,then it shall be"done in its entirety.
INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request hof the Building-official
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert J.M.Nieminen,P.E. T,�, "p Thefacs,m,lesealappearing was authorized byRobert
Florida Registration No.59166,Florida DCA ANE1983 ''c.s� Niem(nen,P.E.'on 10/06/2017. This does not serve as an
9 t_� ,++.. , .
�Jsy„.+n-• electronically signed document
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
,
distributing products it evaluates. I 3
2. Trinity)ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturinglor distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire, a financial interest in any other entity inviolved inAhe approval process of the
product.
S. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E.are; in any way,thel Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting.or design guidance unless retained
specifically for that purpose.
l . � J
" i I
I I
1'RINI
Y ERD
ROOFING COMPONENT EVALUATION:
i
1. SCOPE:
i
Product Category: Roofing
Sub-Category: U nderlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the
11
following sections of the 6th Edition (2017) Florida Building Code through t II sting in;accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations % Conditions of Use set forth
-herein.
2. STANDARDS:
;
Section Property Standard Year
1504.3.1 Wind Resistance FM 4474 2011
1504.3.1 Wind Uplift UL 1897 j 2012
1507.1.1,T1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015
1507.3.3 Physical Properties FRSA/�IRI April 2012 I 2012
FRSA/TRI April 2012(04-12) Physical Properties ASTM D6163 2008
TAS 110 Accelerated Weathering TAS 110 2000
3. REFERENCES: I
Enti Examination Reference Date
ERD(TST6049) ASTM D1970/TAS 110 2968.05.04-2 a 05/14/2004
ERD(TST6049) Physical Properties 2757.02.05 ? 02/03/2005
ERD(TST6049) ASTM D1970/TAS 110 2974.03.05-2 05/17/2005
ERD(TST6049) Wind Resistance 2778.07.05 I ' 07/15/2005
ERD(TST6049) Wind Resistance 2779.11.05-R104/18/2007
ERD(TST6049) TAS 103/TAS 110 57120 11.07-2 11/02/2007
ERD(TST6049) ASTM D1970/TAS 110 S13190.02.09-R1, 04/01/2010
ERD(TST6049) ASTM D1970/TAS 110 S31370.03.10-1-R1 I 04/07/2010
ERD(TST6049) Physical Properties/Tensile Adhesion S11150.05.10-R1 09/09/2010
ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.09-R2 10/05/2010
ERD(TST6049) ASTM D1970 537210.11.11 11/09/2011
ERD(TST6049) ASTM D1970 540540.02.13-1 02/19/2013
ERD(TST6049) Physical Properties/Tensile Adhesion S43530.02.14-1,a 02/21/2014
ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02:15 02/13/2015
ERD(TST6049) Accelerated Weathering SOPC-SC8520.14 04/17/2015
ERD(TST6049) Wind Resistance SOPC-SC1404S.035.17-R1 06/07/2017
M-D(CER1592) HVHZ Compliance 15-0508.04 09/24/2015
ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 ; 03/01/2017
PRI(TST5878) Physical Properties SOP-064-02-01 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY140 06/29/2015
UL,LLC(QUA9625) Quality Control Service Confirmation Exp.07/18/2020
4. PRODUCT DESCRIPTION:
4.1 Lastobond TU HT is a self-adhering, non-woven polyester fabric surfaced, SBSIII modified bitumen roof
underlayment;meets ASTM D1970 and FRSA/TRI April 2012(04-12). k I
4.2 Lastobond Shield is a self-adhering, woven polyethylene si rfaced;, SBS 'modified bitumen roof
underlayment available in two widths;36 and 45 inch;meets ASTM D1970
4.3 RESISTO SA SMOOTH PLY 40 is a self-adhering,woven polyethylene surfaced, SBS modified bitumen roof
underlayment;available in 3.3 ft x 65 ft rolls;meets ASTM D1970.'
4.4 Lastobond Shield HT is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified
bitumen roof underlayment;meets ASTM D1970.
Exterior Research and Design,U.C. Evalu tion Report518010.06.09-1111
Certificate o/Authorization#9503 6"EDITION(2017)FBC NON-HVHZ EVALUATION I FL2569-1113
Soprema,Inc. Revision 11:10/06/2017
j I Page 2 of 8
I
1
' I
a `rte T I I Q ® !ERS.r'
4.5 Lastobond Pro HT-N is a self-adhering, woven polyethylene surfaced; SBS modified bitumen roof
underlayment available in two widths;36 and 45 inch;meets ASTM D1970.
4.6 Lastobond Pro HT-S is a self-adhering, woven polyethylene surfaced, high tem erature, SBS modified
ibitumen roof underlayment;meets ASTM D1970.
4.7 Lastobond 195 is a self-adhering, glass-mat reinforced, sand-surfaced; SBS modified bitumen roof
underlayment;meets ASTM D1970.
4.8 Lastobond Eaves Protection Sheet is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified
bitumen roof underlayment;meets ASTM D1970. {
4.9 Lastobond Eco is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof
underlayment;meets ASTM D1970.
4.10 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced, film-surfaced) SBS modified bitumen
{ roof underlayment;meets ASTM D1970.
4.11 RESISTO LB1236 is aself-adhering, glass-mat reinforced, sand=surfacec3,i SBS modified bitumen roof
underlayment,with a 36-inch sheet width;meets ASTM D1970.
4.12 PrimeSource Grip-Rite Eave&Valley Protector is a self-adhering,glass-mat'reinforced,sand-surfaced,SBS
i
modified bitumen roof underlayment,with a 36-inch sheet width;meets ASTM D1970.
4.13 RESISTO LB1244 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS (modified bitumen roof
underlayment,with a 44-inch sheet width;meets ASTM D1970.
4.14 Colphene FR GR is a self-adhering, fiberglass reinforced, granule-surfaced, SBS-modified bitumen roof
underlayment;meets ASTM D1970 and FRSA/TRI April 2012(04-12).
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record:for any project on which this Evaluation Report, or preivious Iversions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be.made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof
covering.
5.5 Allowable Roof Covers:
TABLE 1:':ROOF-COVER OPTIONS II {
I
Asphalt Nail-On Foam-On Wood Shakes&
Underla ment Metal Slate
Shingles Tile Tile jJi Shingles
Yes ,I i,
Lastobond TU HT Yes Yes See 5.52 Yes '1;1___..
es Yes
Lastobond Shield/Pro HT-N/RESISTO SA
Yes No No i No Yes Yes
SMOOTH PLY 40
Lastobond Shield HT/Pro HT-S Yes No..': No 11 Y'es Yes' Yes
Lastobond Eaves Protection Sheet/Lastobond 195 "Yes No No �I, IVb - Yes Yes•.
Lastobond ECO /RESISTO LB1236,Grip- 't {
Rite Eave&Valley Protector/RESISTO Yes No, No �;. !IVo Yes Yes
LB1244
U.C. Evaluation Report 518010.06.09-1111
'
Exterior Research and Design, �
Certificate of Authorization#9503 6"EDITION(2017)FBC NON-HVHZ EVALUATION I FL2569-R13
Soprema,Inc. i Revision 11:10/06/2017
Page 3 of 8
' t
I
,
i
1
I
- ' RIN
TABLE 1 ROOF COVER OPTIONS
_ - II'
Asphalt Nail-On Foam-On Wood Shakes&
Underlayment Shingles Tile Tile M6,1 al i Shin les Slate
g
Lastobond Smooth Seal HT Yes No;`.. No jj Yes Yes. Yes,
,j
Colphene FR GR Yes Yes Yes I N6 Yes -Yes'
See 5. .
5.5.1 "Foam-On Tile"is limited to use of following Approved tile adhesives J underlayment combinations.
TABLE1A;ALLowABLE TILEADHESIVE J IINDERLAYMENT CONIBINATIQNS
Adhesive Florida Product Approval Widerlayments
Dow TileBond"' FL22525 Lastobond TU HT j
ICP Adhesives Polyset"AH-160 FL6332 Lastobond TU HT or Colphene FR GR
5.6 Allowable Substrates:
5.6.1 Direct-Bond to Deck: i
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 401 Lastobond Shield HT, Lastobond
Pro HT-S, Lastobond TU HT,Lastobond Eaves Protection Sheet, Wstobond1195,Lastobond ECO, RESISTO
LB1236,Grip-Rite Eave&Valley Protector,RESISTO LB1244 or Lastobond Smooth Seal HT applied to:
➢ Plywood; ASTM D41 primed plywood; OSB;ASTM D41 primed.OSB; SoUthernl Yellow Pine; ASTM D41
primed Southern Yellow Pine;ASTM D41 primed structural concrete. "
Colphene FR GR applied to:
i Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete.
Note:
While not required over plywood, OSB or Southern Yellow Pine sulitrates, Soprema recommends
priming with Elastocol Stick or Elastocol 600c if the final roof clover is not slated for installation within
24 hours.
Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to
installation of the self-adhering underlayment.
5.6.2 Bond-to-Insulation: f
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond
Pro HT-S,Lastobond TU HT, Lastobond Eaves Protection Sheet, Wstobodd!195, Lastobond ECO, RESISTO
1.61236, Grip-Rite Eave &Valley Protector, RESISTO LB1244, Lastobond Sinoothi Seal HT or Colphene FR
GR applied to:
Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam-on tile systems(Lastobond TU HT only),insulation attlachment shall be designed by a qualified
design professional and installed based on testing of the insulation/underlayment system in accordance
with FM 4474,Appendix D,Testing Application Standard TAS 114fil
Appendix J or 1UL1807.
1 I
i '
i
Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning;Marne nt Resistance Performance.
Exterior Research and Design,I.I.C. Evaluation Report 518010.06.09-1111
Certificate ofAuthorizatiori#950 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-1113
Soprema,Inc. i Revision 11:10/06/2017
Page 4of8
I
' I
I
1IN
+ERD
5.6.3 Bond to Mechanically Attached Base Laver:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-5, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 1`5; Lastobond ECO, RESISTO
LB1236,Grip-Rite Eave&Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR
applied to:
> ASTM D226,Type I or II felt;Sopra-G;Modified Sopra-G.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam-on I the sysltems (Lastobond TU HT only),
base layer shall be attached in accordance with FRSA/TRI April 2012(04-12).
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications,i FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where
the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment
systems that are not addressed in FRSA/TRI April 2012 (04-12) anld are used in foam-on tile applications.
Maximum Design Pressure is the result of testing for wind load resistance'based on allowable wind loads,
and reflects the ultimate passing pressure divided by 2 (the 2 to 11 marginiof safety per FBC 1504.9 has
already been applied). Refer to FRSA/TRI April 2012(04-12)or FBC 1609 for determination of design wind
pressures. A
#1 Maximum Design Pressure=-45.0 psf: �
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional)Elastocol Stick,Elastocol 600c or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT or Colphene FR GR,self-adher i�d. )
#2 Maximum Design Pressure=-67.5 psf:
Deck: Structural concrete to meet project requirements'to satisfaction of Authority Having
1 ,
Jurisdiction.
Primer: Elastocol 600c
Underlayment: Lastobond TU HT or Colphene FR GR,self-adher d.
#3 Maximum Design Pressure=-150.0 psf:
Deck: Min. 15/32-inch APA-rated BCX plywood (may ibe installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit
adhesion. All sheathing fasteners shall be driven flu' h with the surface. All sharp
splinters and wood projections shall be removed/sanded. g
Primer: (Optional)RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, self-adhered, shall be thoroughly; ;roll using hand roller and/or
weighted roller to ensure there are no voids, and ensures there)are no voids/bridging at
side and end-laps.
#4 Maximum Design Pressure=-60.0 psf: { +
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin
caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three (3),
equally spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered
5.6.4.1 All other direct-deck, adhered Soprema underlayment systems; beneath; foam"-on tile systems carry a
Maximum Design Pressure of-45 psf.
j � I
c
Exterior Research and Design,LC. j Evaluation Report 518010.06.09-1111
Certificate of Authorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-1113
Soprema,Inc. { Revision 11:10/06/2017
1 Page 5 of 8
. i
, i
i
TRINE ERR
5.6.4.2 For mechanically attached Base Sheet,.the maximum design pressure for the selected assembly shall meet
or exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A:i
Alternatively,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1
design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an
attachment density designed by a qualified design professional to resist'the elevated pressure criteria.
Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk` carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 20/3 enhancements-.
5.7 Exposure Limitations:
Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO
LB1236,Grip-Rite Eave&Valley Protector or RESISTO LB1244 shall not bOeft exposed for longer than 30-
days after installation. s I
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY40, Las';tobond�Shield HT or Lastobond
Pro HT-S shall not be left exposed for longer than 90-days after installation'. i
i
Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than 1801days after installation.
5.8 Tile Slippage Limitations(TAS•.103 per FRSA/TRI April 2012(04-12))I
When loading roof tiles on the underlayment in direct-deck tile aslsemblie's,,the maximum roof slope shall
be as follows. These slope limitations can only be exceeded by uising battens during loading of the roof
tiles. d
I
TABLE 2 TILE SUPPAGE LIMITATIONS FOR DIRECT-QECK TILiE INSTALLATIONS
II �
Underlayment Tile Profile Staging M7�! " Maximum
ethod Slope
Flat Max.10-tile stack) 6:12
Lugged Max.10-tile stack] 5:12
Max.10-tile stack(bottom 2-tile stack
shall be inverted,folloj�ed by�8 tiles high 6:12
on slope,as shown below)
Lastobond TU HT
Lugged
} i k
nI
1( say
4
Colphene FR GR
Flat ,Max.10-tile stack 5:12
i
Lugged Max.10-tile stacks 6:12
• i
i f
I fi 1
i r
I
I
I "1
i
Exterior Research and Design,LLC. Evaluation Report S18010.06.09-1111
Certificate of Authorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION F1.2569-1113
I Soprema,Inc. Revision 11:10/06/2017
! ! Page 6 of 8
; I
I : , i
1
{
TRINITY!€RD
6. INSTALLATION:
6.1 Soprema Roof Underlayments shall be installed in accordance with Sdprema published installation
requirements subject to the Limitations set forth in Section 5 herein and thespecifcs noted below.
6.2 Re-fasten any loose:decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application,and prime the substrate with Elastocol Stick, Elastocol
600c or RESISTO EXTERIOR PRIMER (if applicable). 1
6.3`-'-' Lastobond TU HT,Lastobond Shield,"La Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield .
HT,.,Lastd6dnd Ped.HT S, Lastobond Eaves.Protection Sheet,Lastobond',195; Laftobond Eco,Lastobond-
Smooth Seal.HT,RESISTO.L131236 Gnp RR6 Eave&•Valley Protector,RESIS1i0 LS1244 or'Cdiphene FR GR:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table
1507.1:1 for the type of prepared roof covering to be installed.
6.3.2 Non-Tile Applications: ,
While priming is optional, Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO
EXTERIOR PRIMER if the final roof cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film. j
Adhere the exposed part to the substrate and unroll the remainingmembrane as far as possible.
Once the entire length of membrane is in place, peel-off the release film diagonally while holding the
membrane tight. Firmly roll the membrane into place to achieve aibond.
Horizontal seams should be minimum 3-inches, configured to shed wateri Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course beIOw. All over-granule end-laps
shall be sealed using either heat-welding or hot air welding techniques.
When installing at slopes above 8:12,Soprema recommends backl,nailing in the oiverlap area at the top of
the sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths.,Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the centerof the valley or ridge in
each direction. For valleys,apply the sheet starting at the lowest point and nrork upward.
6.3.3 Tile Applications(Lastobond TU HT or Colphene FR GR on1V1:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual. and Table 1 herein, using the
instructions noted above as a guideline.
For foam-on tile applications, reference is made to Section 5.6.4 herein foc,wind rsistance limitations that
fall outside the scope of FRSA/TRI April 2012(04-12). ' '
Tile shall be loaded and staged in a manner that prevents tile slippage ,and/or damage to the.
underlayment. See Table 2 herein,and Soprema published requiri ments fair tile staging.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in orde' to properly evaluate the installation of
this product. I
r ,
� t1
Exterior Research and Design,I.I.C. Evalu on Report S18010.06.09-1111
Certificate of Authorization X950 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-R13
Soprema,Inc. Revision 11:10/06/2017
1 i Page 7 of 8
i
I
' I
i
RINITY}ERD
8. MANUFACTURING PLANTS: !�
Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements.
The following plants have qualified products under their respective physical pii operties{specifications.
Plant--` Specificetiori Product 5 �I
Lastobond Shield,RESISTO SA SMOOTIi PLY 40, Lastobond Shield HT,
Lastobond Pro HT-N,Lastoblond Pro HT-S,Lastobond 195,Lastobond
Drummondville, II
ASTM D1970 Eaves Protection Sheet,Lastobond Ecd,Lastobond Smooth Seal HT,
QC(Canada) RESISTO LB1236,PrimeSouri a Grip-Rite Eavel&Valley Protector,
RESISTO LB1244
ASTM D1970&FRSA/TRI 04-12 Colphene FR GR �� f
Wadsworth,OH Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Eco,
ASTM D1970 Lastobond Smooth Seal HT,RESISTO LB1236,1PrimeSource Grip-Rite
Eave&Valley Protector,RESISTO LB 12{44
ASTM D1970&FRSA/TR1.04-12 Lastobond TU HT;Colphene'FR GR
Gulfport,MS
Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Eco,
ASTM D1970 Lastobond Smooth Seal HT,RESISTOI s,LB1236� ,I PrimeSource Grip-Rite
Eave&Valley Protector,RESISTO L612{44
I
9. QUALITY ASSURANCE ENTITY:
UL,LLC—QUA9625;(314)57873406;k.chancellor@us.ul.com
� 1 I
-END OF EVALUATION REPORT-
' I
it
a
I
,
. i
,
i I
I
p ,
I 1
i
i
I .I
' II
� I
Exterior Research and Design,I.I.C. -Evaluation Report 518010.06.09-1131
Certificate ojAuthorization#9503 6"EDITION(2017)FBC NON-HVHZ EVALUATION FI-2569-1113
j 5oprema,Inc. Revision 11:10/06/2017
I
I . Page 8 of S
I i l
Florida Building Code Online Page 1 of 2
„
Ilk
a�
4!1
.s•.�2.,Y4_�.�-....�.«...�}e.�:r'S�.a-...�..�w. �. w.�..�T.=-,...w/'. .�..<...�..w�...sa'+v.�....:+..+.� 4 4 -..,•.:3 R h:Xc'siR1+..v S.un,...v[..�{.
BCIS Home : Log In , User Registration HoC Topics t Submit Surcharge Stats&Facts Publics ions FBC Staff i BYCIS Site Map Links Search
' Product Approval
USER:Public User
1
Product Approval Menu>Product or Apolica[ion Search>Apli[atlon List>Application Detail
FL# FL10674-R13
Application Type Revision ;
Code Version 2017
Application Status Approved
I �
Comments
Archived
I
Product Manutacturer Owens Corning
9 '
Address/Phone/Email One Owens Corning Parkw y
Toledo,OH 43659
(740)404-7829
greg.keeler@owenscorningiImm
II
Authorized Signature Greg Keeler
greg.keeler@owenscorningi com ;
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo,OH 43659
(419)376-8360
mel.sancrant@owenscomig.com
i
Quality Assurance Representative ;
Address/Phone/Email
"
Category Rooting
I '
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert J.M. Nieminen i
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC ,
I
Quality Assurance Contract Expiration Date 05/16/2020
Validated By John W. Knezevich,PE
c4 Validation Checklist-Hardcopy Received
Certificate of Independence FL10674 R13 COI 1 COI Nieminen:D>�
I
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2016
ASTM D3462 2010
ASTM D7158 I 2011
Equivalence of Product Standards
Certified By
Sections from the Code
I
i f •I
http://www.floridabuiIding.org/pr/pr_app_dtl.aspx?param=vGEVXQwtDgtBNbE- V0/o2... 1/15/2018
Florida Building Code Online . _ Page 2 of 2
I q
I
1 I ,
Product Approval Method Method 1 Option D
Date Submitted. 10/10/2017 ;
Date Validated 10/11/2017
Date Pending FBC Approval 10/15/2017
Date Approved 12/12/2017 J
SummarV of Products
I I
FL# Model,Number or Name Description I I
10674.1 Owens Coming Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge
Shingles and Starters shingles II i
Limits of Use Installation Instructions;
Approved for use in HVHZ:No FL10674 R33 II 2017 10'FINAL ER OC ASPHALT
Approved for use outside HVHZ:Yes SHINGLES FL 10674-1113.bdf
Impact Resistant:N/A Verified By: Robert J.M. Niemine.PE-59166
Design Pressure:N/A Created by Independent Third Party:Yes
Other:Refer to ER,Section 5. Evaluation Reports i j 1
FL10674 R13 AE 2017 10 FINAL ER OC ASPHALT
SHINGLES FL10'674-R13.Ddf
Created by Independent Third Party:Yes
I
Back Next
` 1I
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Stat el ent..AccesSlbillty Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do notsend
electronic mail to this entity.instead,contact the office by phone or by traditional mail.If you have any questions,'please contact 850.487.1395.`Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,FS.,please click here.
Product Approval Accepts:
Cred:i Card
Safe
W' t "
I
i
I ,
I
I ,
I g '
I
I r I
I
http://www.flofidabuilding.org/pr/pr_app_dtl-aspx?param�wGEVXQ it DgtBNbEY5V%2... 1/15/2018
9
EXTERIOR RESEARCH&DESIGN, LLC.
u Certificate of Authorization#9503
353 CHRISTIAN STREET,UNIT#13
TY''� � OXFORD,CT 06478
I �,, I �
(203)262-9245
EVALUATION REPORT''
Owens Corning I Evaluation Report 037940.02.12-R8
One Owens Corning Parkway ,i FL10674-R13
Toledo,OH 43659 ;Date of Issuance:02/06/2012
(740)404-7829 { 'Revision 8: 10/09/2017
I
SCOPE: '
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules land regulation) governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6 Edition;(2017)1Florida Building Code
1
sections noted herein. j
DESCRIPTION: Owens Corning Asphalt Roof Shingles
1
LABELING: Labeling shall be in accordance with the requirements the Accred'tedQuality Assurance Agency noted
herein and FBC 1507.2.7.1/R905.2.6.1.
I
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. Trii yJ ERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code.. Cie.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity,J ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done In its entirety.
INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the" user by the manufacturer or
its distributors and shall be available for inspection at the job site at the requestll f the Bdilding�Oficiall.
i
This Evaluation Report consists of pages 1 through 8. ;
Prepared by:
Robert J.M.Nieminen,P.E. l%cS-�''1""��•'s` ThefacsimilesealappearingwasauthorizedbyRobert
�JJbn\iin�t�``a•
Florida Registration No.59166,Florida DCA ANE1983 Nieminen,P.E.''on 10/09/2017.This does not serve as an
electronically signed d l ument.
CERTIFICATION OF INDEPENDENCE: 11
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest:in any;icompany manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products,it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any compariy manufacturing]or distributing products for
which the evaluation reports are being issued.
i
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved inIthe approval process of the
product. 1
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the'Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting'or design guidance unless retained
specifically for that purpose. {
' I
I
i
1
.tVl a.' � P...E't."a�
ROOFING SYSTEMS EVALUATION: i1
I
1. SCOPE:
I I
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles,as producediby Owens Corning, have demonstrated
compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards.; Compliance is subject to the
Installation Requirements and Limitations/Conditions of Use set forth hereinl,
i
2. STANDARDS:
Section Property Standard �I Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 1 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011
3. REFERENCES:
I �
Enti Examination Reference Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vo1.�3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-132453 ! 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308, 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter ! 10/02/2015
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs i I Various
UL LLC (QUA9625) Quality Control Service Confirmation 1 Exp.05/16/2020
i
4. PRODUCT DESCRIPTION:
I
4.1 Asphalt Shingles: I 1
4.1.1 Classic'and Supreme'are fiberglass reinforced,3-tab asphalt roof shingles. ! i
A
4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles. i
4.1.3 Devonshire TM are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 Duration•, TruDefinit(on• Duration®, Duration• Premium Cool, TluDefiri ion• Duration• Designer Color
Collection, TruDefinitionAOakridgeb, Oakridge. and WeatherGuarcl iHP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Hip&Ridge Shingles:
i �
4.2.1 Berkshire' Hip &Ridge Shingles, High Ridge, WeatherGuard• HP Hip & Ridge,Shingles, ProEdge Hip &Ridge
Shingles and DuraRidgel Hip&Ridge Shingles are fiberglass reinfor i d,hip and edge asphalt roof shingles.
4.3 Accessory Starter Strips:
i
4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for aIsphalt roof shingles.
S. LIMITATIONS: ' I
5.1 This is a building code evaluation. Neither TrinityiERD nor Robert Niemihen, J:E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used
for permitting or design guidance unless retained specifically for that purpose".
5.2 This Evaluation Report is not for use in FBC HVHZjurisd(ctions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design,I.I.C. R Evaluation Report 037940.02.12-138
Certificate of Authorization#9503 6'EDITION(2017)FBCNON-HVHZ EVALUATION i FL10674-R23
Owens Coming Asphalt Roof Shingles Revision 8.10/09/2017
Page 2of8
i
.I
I
a 0a TE @ +E i-1)
J
5_4 Wind Classification:
5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating thel shingles are acceptable
for use in all wind zones up to Vaed = 150 mph (V„It = 194 mph'). Refer'to Section 6 for installation
requirements to meet this wind rating.
5.4.2 All OwensCorning hip & ridge shingles, Starter Strip Shingle an'd Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM ;1)3161, Class F, indicating the
shingles are acceptable for use in all wind zones up to Vasd=150 mph'(V,,,,=1,9;4 mph), Refer to Section 6 for
installation requirements to meet this wind rating. ;
5.4.3 Classification by ASTM D7158 applies to exposure category B or C,as defined in FBC 1609.4.3, and a mean
roof height of 60 feet or less. Calculations by a qualified design profession{al are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to i each'shingle.
5.4.4 Refer to Owens Corning published information on wind resistance anld installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shallhold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3.
6_2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or
exceptions: with the following
exceptions:
v Berkshire'shingles require minimum five(5)nails per shingle.
➢ WeatherGuard HP shingles require minimum six(6)nails per shingle.
Devonshire TM shingles require minimum six(6)nails per shingled
y Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted. j
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: I '
+ 1
Felt underlayment %<- Deck Fah undertay I ent %i,, Deck Self-adhered
�:.= t'leatlleri.eeii:
?• Self-adhered I endcrlaymcrd
=r, WeatherLocke
(_ underlayment J_
Drip_ - Drip edge
DriDy p edge
edge ;;, edge
- �i. �• ha3s located
frme
Nails I olin eave '2'-1*from cave
• 2"-3` � •�
i
Install first 1
Self•seaGrgadhesive I SWseZng adhesive
Staner St.
Instan Hist Starter Slip Pt u
pp �.' poshinned along cave iosVdoned along cave
shingle with t wRh 6'ramoved--
6"removed
Starter Strip shingle overhangs eaves and rakes'=tilStarter5tnp Pusoverhangs eaves and rakes U4-314"
kjd
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-118
Certificate of Authorization tf9503 6"EDITION(2017)FBC NON-HVHZ EVALUATION i I F1.10674-1113
Owens Corning Asphalt Roof Shingles i If Revision 8:10/09/2017
Page 3 of 8
1 .
{
.5 1'TRIM ti fl i
6.2.6 Minimum Nailing—Classic®&Supreme:
Normal Mansard or Area para Normal Mansard or Area para
Wind Areas High Wind dosvanes y Wind Area High'Wind desvanes y
Area pare vientos norrnales Areas vientos fuertes Area para vientos norrrmaias Areas vientos fuertas
11 1
IAi In•r � z•� f61 r2. t- �tzt _ (A). 121
t•. �t.,l 2.• (BI `2" i.�i
- . • .�" •; T� i
B"Exposure 65/8"Exposure
Sx osicidn '
p Exposici6n l
it
6.2.7 Minimum Nailing—Berkshire®: {
m
Seala�dciril� ;Sealant strip
/La tka de sdlada j la tira de sellador
F-Y o1---t o car 1910
8 Yz" g Vt 9 Ya' 8 4'?' 8 Vz" a
Standard Fastening Pattern 1I 6-Nail Fa!iteningh Pattern
Sealam strip
I
/La fira desdladar
0<* Q-4-->a o r--------D o a
° I
2- Asphalt rool ng aanent
rownto de feaho do astatto !
I
Mansard or Steep Slope Fastening Pattern i
I ,
4 .�
I
Exterior Research and Design,I.I.C. Eval ation Report 037940.02.12-RS
Certificate of Authorization 119503 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113
Owens Coming Asphalt Roof Shingles i Revision 8:10/09/2017
Page 4 of 8
i
i '
TRINITY ERD
I
i 6.2.8 Minimum Nailing—DevonshireT"I:
I
I �
I
I
�r t �tt I 8n I pn I' 8u I 7rr I «�a
O s
gavas I 1
Nails
— r ! e , .
5.5/8"exposure }.
Exposicion de 5.5/8 pulg Sealant location `I
Ubicacion del sellador
Ten 1"Spoas of Asplilalt Roof Cement
Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern
I
6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium I Cool & TruDefinition®
Duration'Designer Color Collection:
4-Nall Fastening Pattern 6•Nall Fastening Pattern
SureYmlD hstenmg area witltl, I SureNaile fastetWrg area tviddr
Nail,Typical I Nailtypical
' 1 b
�— a:.�_.u,r.-a ;�_"_.o:.g Fs.a;.,�•.e�a-.:e _oa,:,c�_ s_. '�.:e; rt—�<T_ ly a.:t e,^. �.c. ":Y o.w...:c._ - i.
rlls 7L
Standard Fastening Pattern6-Nail FasteninglPattern
+ I y
Fastening for Slopes Greater Than 21:12
I
SurofLtit;]teeloning area w+mn I
i
rr-Naa,Typical +'.I
t» 42^ 1 ,Z•I l• i
' I F
ZZ.1
d
I
Four 1^Spore of lupNa(t Rgotlnp Cement ,
Mansard or Steep Slope Fastening Pattern
1 I
I i
' I
I .
I I
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-RS
Certificate of Authorization X19503 6'EDITION(2017)FBC NON-HVHZ EVALUATION I I FL10674-R13
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 5 of 8
I
I a
I
6.2.1 Minimum Nailing—TruDefinition*OakridgeO,Oakridge®:
4 Nail Pattern 6 Nail Pattern it
Esquema can 4 clavos Esquema con 5 clavas
+ I
i I
1• r �
Imo-- 12• �I la— 1r� i � ! � r
I
5 518"EcposureNaSs 5 518"Exposure I Nails
Fxpa51claade5618pufg. clavor Fxposlctinde55/8pulg. 5Biel' posu,e i IClavor 561W,Gxposu
ician 6/epu
,e
Fxpasds 6 'g. Exposicldn de 55/Spulg.
Li I 1
Standard Fastening Pattern I6-Nail Fastening"Pattern
Fastening for Slopes Greater than 21:12 + '
smoxnaz,zstopingmoawlam I � i
('xrl.tvp�wl I ',
I,
.Ir__..
Four,"Spot/of Aspnalt�ng Cement
I
Mansard or Steep Slope Fastening Patter
6.2.1 Minimum Nailing—WeatherGuard®HP: !
I
12.
moire an As&
Fie�c�'PFmsrg7r liidl�r
�
- I I
I
I �
Exterior Research and Design,I.I.C. I �, Evaluation Report 037940.02.12-118
Certificate of Authorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
j Page 6 of 8
I
`f TI ' ER
6.3 Hip&RWe Shingles:
i
6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard' HP Hip and Ridge Shingles
and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions,
using four (4) nails per shingle. Installation of DuraRidgel Hip & Ridge Shingles shall comply with the
Owens Corning current published instructions, using two (2) nailslper shingle. Refer to Owens Corning
published information on wind resistance and installation limitations, including the+use of hand-sealing for
wind warranties. a
6.3.2 Fasteners shall be in accordance with the manufacturer's published require
ments, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge:
Fig.14 Fig.2 I I I
.� rreraiCrlgvana � A�. r,I
Dlrecrinn r.� 'i� \�•.o\ ITaPlA v SidcUcY�
N flails -
\ I Lanlinaled ; "'L2
j 1
plive 1
\p\
I
I
6.3.4 Minimum Nailing—WeatherGuard®HP Hip and Ridge:
I J
Fig.A 7?
Fig.C Hip&Ridge Shingle Fastening
¢_Pmwul W1nd ff\ `F Top VkKvl''a
DlrMbn
MRS Noll9
�2 1.
I' Exposure
I
i
i I
I
l•
,Iv
Exterior Research and Design,I.I.C. , Evaluation Report 037940.02.12-RS
certificate of Authorization 119503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
I Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 7 of 8
, t
� d
a 'I
ill
1
, I I
r ,_
J o�
2
^ • ,` ; TRINITY,ERD
6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles:
>
Prevailliny Standard
11^-•
Wind Direction Sealant Strip
Fastening
j
\� i LI
6„Exposure
Sealant
Fasten 6"IcxposliIr
Corer Exposed I 1 1 ,
Fasteners with
-Roof Cement I, la„ I
� f I
I •
6.3.6 Minimum Nailing—DuraRidge""Hip&Ridge.Shingles:
Note:The drawings below pertain to minimum,as-tested attachment. Refer to Owens Corning
published installation instructions for their minimum requirements. {
Pro%iinglYrd DirKdcn Top View'
iroaionck"iramo.ilemc Vw eo plan
Diracdcndolrisntaprodarnimnco HI" �Visosuperlar,; 1'yi
a '1 I
rI
I
2s J+0 Ovrens Comlisg r 5nIla1 7 0' CRM
CCmo: = yy a\ I I I
II � •
1 �
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FISC
Table 1507.2.7.1/13905.2.6.1. I
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evi luate the installation of
this product.
1 �
9. MANUFACTURING PLANTS: 'i d
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY: {
UL LLC—QUA9625;(631)546-2458;Kanchi.Agrawala-Dokania@ul.com i
END OF EVALUATION REPORT-