HomeMy WebLinkAboutProduct Approval it
i II
II _ ® B f +E9iL.1
i I I I
ROOFING SYSTEMS EVALUATION:
1. SCOPE: 1
i it I
Product Category: Roofing
Sub-Category: Asphalt Shingles II
Compliance Statement: Owens Corning Asphalt Roof Shingles,as producediby Owel s Corning, have demonstrated
compliance with the following sections of the 6 Edition (2017) Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Staindards.I !Comp;liance is subject to the
Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS: j
Section PropertV Standard I Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 �; 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 i 2011
3. REFERENCES:
I,
Entity Examination Reference Date
UL LLC.(CER9626) Physicals&Wind Resistance File R2453,V01.11 13 1 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 1 04/18/2006
UL LLC(TST9628) Wind Resistance11CA34308 02/18/2012
1 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 I 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter I,' 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation 4' Exp.05/16/2020
4. PRODUCT DESCRIPTION:
I
4.1 Asphalt Shingles:
4.1.1 Classic'and Supreme'are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 Devonshire T41
are fiberglass reinforced,5-tab asphalt roof shingles.
I 4.1.4 Duration, Tru Definition' Duration Duration® Premium Cool, TrIuDefinition Duration Designer Color
Collection, TruDefinition'Oakridge', Oakridge and WeatherGuard®;HP are fberglass reinforced, laminated
asphalt roof shingles.
4.2 Hip&Ridge Shingles:
4.2.1 Berkshire' Hip &Ridge Shingles, High Ridge, WeatherGuard HP Hip &Ridge Shingles, ProEdge Hip &Ridge
Shingles and DuraRidgeT""Hip&Ridge Shingles are fiberglass reinforeied,hip and ridge asphalt roof shingles.
4.3 AccessorV Starter Strips:
4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
i I
S. LIMITATIONS: Li!
5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Niemiken, P.E. are, in any way, the
I!
Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used
for permitting or design guidance unless retained specifically for thatpurpose,
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. I 1 I
5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory
` for fire ratings of this product.
I I
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS
Certificate oJAuthorization 119503 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1213
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
J
Page 2of8
J
I
I �
I
i
x TRINITY ERD
5_4 Wind Classification:
5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating the,shingles are acceptable
for use in all wind zones up to Vasd = 150 mph (V„lt = 194 mph). Ref& to Section 6 for installation
requirements to meet this wind rating. I
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter; Strip Plus noted herein are
Classified in accordance with FOC Tables 1507.2.7.1 and R905.2.6.1 to ASTIV6 iD3161, Class F, indicating the
shingles are acceptable for use in all wind zones up to Vasd phl(150 mp (V,It=194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean
roof height of 60 feet or less. Calculations by a qualified design professional are)required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each Ishingle.
I
5.4.4 Refer to Owens Corning published information on wind resistance and' installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit ini accordance with F.A.C.Rule 61G20-3.
6. INSTALLATION:
6_1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3.
6_2 Asphalt Shingles:
II �"
6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or'13905.2.6, with the following
exceptions:
> Berkshire'shingles require minimum five(5)nails per shingle. jl
> WeatherGuard HP shingles require.minimum six(6)nails per shingle.
> Devonshire'"shingles require minimum six(6)nails per shingle:
> Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip.
i
Refer to Owens Corning published information on wind resistance and installfation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted. �I
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details. �,'
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: I i
Feltunderlaynient - Deck Fe@undedn went %�, Deck Self-adhered
L� y %Yeatherto&h
'trf Self-adhered underlaymerd
rWeatherLocko ,� � � /
i
rr`. underlaynient
D� - Drip edge
— ^1 Drip edge
edge
edge
edge I`,
Nails located Naas located
2=3"lrnm eave V-3'from eave
I •
Install first Self-sealing adhesive 5�nsa5ng adhesive
Starter Stripp •y� poshioned along cave inste@ first Starter Strip PP.rs �.%% posrdoned along eave
shinglewit '-._ 1 vfhh 6"removed——=: j'
G"remover)
Starter Strip shingle overhangs eaves and rakes;5=ril' Starte Strip overhangs eaves and rakes 1W-314'
i
I
i
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS
Certificate of Authorization 119503 6"1
EDITION(2017)FBC NON-HVHZ EVALUATION i F1.10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
I ! Page 3 of 8
ED
6.2.6 Minimum Nailing—Classic®&Supreme:
I..
-
Normal Mansard or Area para Normal I" Mansard or Area para
Wind Areas High Wind dosvanas y Wind Areas i High Wind desvanes y
Area porn vientos normajes Areas vientos fuertes Area porn vienros normaJes Areas vientos fuertes
I I'
2'7 t" (A}. I rt'I z" IBI r2-
tri. tr .-tzt i II tzt
i�L1 II I i i
osure
5"Exposure 5 Sfi-Exp
Exposition Exposic'ion
II I' I
6.2.7 Minimum Nailing—Berkshire®:
I I• I
I ,
SealaNdrip j Sealantstrip
r La tin de:;DQcW is taa de sellador
0-0
0 W. 9 Y?' 8 V3' � � 8 Vi" 8
t., t" p
1 I I
� 1 I
I i I I
Standard Fastening Pattern !6-Nail Fastening Pattern
II I;'. �
II I
I � i
I
I
sealant strip
t.a!in de-Alador
I
8 �
I
{e Asphalt roofing cement ' I
Commit de locho do a tafto
{ Mansard or Steep Slope Fastening Pattern I'
,
i
I
� I
, I
,
I I i i
I
I
Exterior Research and Design,LLC. I Evaluation Report 037940.02.12-RS
Certificate oJAuthorization#9503 6"EDITION(2017)FBC NON-HVHZ EVALUATION ( , F1.10674-1113
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
" Page 4 of 8
I ,
i
Florida Building Code Online li Page 1 of 2
I I
i
,ate r c v_ t i -
t
BQS Home t tog In User Registration Hot Topics. Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map ` Links `. Search '.
L-�"-if
a
0i -
d
Product Approval USER:Public User
Product Approval Me,rLu>Product or App ication Search>Application List>Application Detail
I
ROMa FL# FL10674-R13
A'Ylx. ....;il
��i_L I
Application Type Revision
Code Version 2017 I! I
Application Status Approved
I I
Comments
Archived I
i
Product Manutacturer Owens Coming
Address/Phone/Email One Owens Corning Parkway
Toledo,01-143659
(740)404-7829
greg.keeler@owenscorning:com
I
Authorized Signature Greg Keeler
greg.keeler@owenscoming.com
I �
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY I
Toledo,OH 43659
(419)376-8360
mel.sancrant@owenscomig.com ,
II I
I
Quality Assurance Representative
Address/Phone/Email
I!
Category Rooting ,
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
s Evaluation Report- p Hardcopy RI ceived rl '
I ,
Florida Engineer or Architect Name who developed Robert 3.M. Nieminen
the Evaluation Report II
i Florida License PE-59166 '
I
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 05/16/2020
Validated By John W. Knezevich,PE
�! Validation Checklist-Hardcopy Received'
!I . �
Certificate of Independence FL10674 R13 COI 207 :O1 COI Mii en!D
emind�
Referenced Standard and Year(of Standard) Standard i
Year
ASTM D3161 2016
ASTM D3462 ii 2010
ASTM D7158 I' 2011
� I
i
Equivalence of Product Standards I i'
Certified By
Sections from the Code
I 111;
littp://www.floridabuilding.org/pr/pr�_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2._. 1/15/2018
Ij
Florida Building Code Online _ Page 2 of 2
II I
.I
I I �
Product Approval Method Method 1 Option D i
i
Date Submitted 10/10/2017
Date Validated 10/11/2017
Date Pending FBC Approval 10/15/2017
Date Approved 12/12/2017
I i
SummarV of Products
FL# Model,Number or Name Description I" I
10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,54 b,laminated,starter and hip&ridge
Shingles and Starters shingles I;
Limits of Use Installation Instructions'
Approved for use in HVHZ:No FL10674 R13 II 2017 10,FINAL ER OC ASPHALT
Approved for use outside HVHZ:Yes SHINGLES FL10'674-R13.pdf
Impact Resistant:N/A Verified By: Robert J. M. Nieminen PE-59166
Design Pressure: N/A Created by IndependentYliird Pariy:Yes
Other: Refer to ER,Section S. Evaluation Repbrts
FL10674 R13 AE 2017 10 FINAL ER OC ASPHALT
j SHINGLES FL10674-R13:pdf
Created by Independent 11' ird Party:Yes
Back Plext IIS I
I I
I
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Ph Ina:850-497-4824
The State of Florida is anAA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Stat mI1'eent
Accessibility Statement::Refund Statement
I
Under Florida law,email addresses are public records.If you do not want your e-mail address releases in respq I I to apublic-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.`Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,IF.S.must provide the Department with an email address if
they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to thelpublic.To determine if you are a licensee under
Chapter 455,F.S.,please click here
k Product Approval Accepts: I i1
I
Credit Gard
Sate
i
it
li ''I i
n I
'I I
II
II
I �
II
i I
I 1
I
I
, I I
h
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQ, tOgtBNbEY5V°io2... 1/15/2018
I► il� I
i I
I
EXTERIOR RESEARCH&DESIGN, LLC.
S` Certificate of Authorization#9503
_. 353 CHRISTIAN STREET,UNIT#13
,1
TRINITY ;`ERD OXFORD,CT 06478
(203)262-9245
EVALUATION REPORT
Owens Corning Evaluation Report 037940.02.12-R8
One Owens Corning Parkway FL10674-1113
Toledo,OH 43659 Date of Issuance:02/06/2012
(740)404-7829 �; I Revision 8: 10/09/2017
I I
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules land regulation's governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th IEditionl(2017)1 Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
I '
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1/R905.2.6.1. f
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as!the nained product(s) changes, the
I;
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. Trinity[ERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each CodelCycle. I
ADVERTISEMENT: The Evaluation Report number preceded by the words Trinity)ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall by done;in its entirety.
INSPEcnoN: Upon request,a copy of this entire Evaluation Report shall be provided to the user!by the manufacturer or
its distributors and shall be available for inspection at the job site at the request,of the Bii,ilding Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert J.M. Nieminen,P.E. ��;�5 - 'S?;` The facsimlle seal appe I ring was authorized by Robert
Florida Registration No.59166,Florida DC4ANE2983 ,- Nieminen,P.E.on 10/09/2017.This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE: I'
1. Trinity}ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any;company manufacturing or
distributing products it evaluates. I;
2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing,or distributing products for
which the evaluation reports are being issued. i
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in Ithe approval process of the
product.
5. This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are,;in any way, the�Designer of Record for any
project on which this,Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose. I '
I
I '
I If
I