Loading...
HomeMy WebLinkAboutProduct Approval v RECEIVED MAR 12 ���' Permitting 1 EXTERIOR RESEARCH &DESIGN, LLC. ST. L�u'ciye County, _ Certificate of Authorization 1J9503 TRINI I 1 353 CHRISTIAN STREET, UNIT#13 ERD OXFORD,CT 06478 (203)262-9245 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-R8 One Owens Corning Parkway FL10674-1113 Toledo,ON 43659 Date of Issuance:02/06/2012 (740)404-7829 FILE CO Revision 8: 10/09/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: 3o s?:'es Robert J.M. Nieminen,P.E. .,`s,�=` `g`�,: The facsimile seal appearing was authorized by Robert Florida Registration No.59166,Florida DCA ANE1983 —�"��� ""' Nieminen,P.E.on 10/09/2017.This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Trinity lERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity lERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. v TRINITY ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: Entity Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme" are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire} are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 Devonshire"are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration, TruDefinition" Duration", Duration" Premium Cool, TruDefinition" Duration" Designer Color Collection, TruDefinition"Oakridge', Oakridge' and WeatherGuard' HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Hip&Ridge Shingles: 4.2.1 Berkshire' Hip & Ridge Shingles, High Ridge, WeatherGuard' HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and Dura Ridge'" Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Accessory Starter Strips: 4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 2 of 8 TRINITY ;ERD 5.4 Wind Classification: 5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to Vasd = 150 mph (V,,,t = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vasd= 150 mph (V,I,= 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3, per FBC 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: Berkshire*shingles require minimum five(5)nails per shingle. WeatherGuard*HP shingles require minimum six(6)nails per shingle. Devonshire'" shingles require minimum six(6)nails per shingle. Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: Feltundedayment Deck Feturderrymem Deck SeR+dnred WatImLockv Self-adhered audedeyntant weatherLock• underlayment Drip_ Drip edge Drip--. edge edge tet• Nair kteatad Naas located 2'-7'firm save ham eave Install fust Self sealing adhesive Install!first Starbr Strip Pksd�s Sr/ionadhesive Starter Sfripp \ positioned along eave ,with e'removed \ �abtq save shingle witft 6'removed ,. Starter Strip Plus eaves and rakes 1/4'-7l4' Starter Strip shingle overhangs eaves and rakes r"-,i tr4 overhangs Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 6-EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 3 of 8 TRINITY'ERD 6.2.6 Minimum Nailing—Classic®&Supreme: Normal Mansard or Arta pI Normal Mansard or Arae pari Vkqnd Ana A n vlsntos nornra/ss Niplt Wind dssysnsAnes Arms nd � pa Amas viantos/verpan W.I.normal# n• ' t hP Escposun 5 hlM Expomwe EsposW41in 16e 6.2.7 Minimum Nailing—Berkshire®: Seahrrt strip S•Iwd strip U tin do sago" U tirr do s0ador •t-� a a--i s r-i• Is • • • • • 8l4• 9Vf 9W 8Vf V . 8W a?h" 8W 1 t• t' t t.J r s r Standard Fastening Pattern 6-Nail Fastening Pattern Sealant strip r,tina do so I&W r s of s of s of 8+:f r r 2• Asphalt roofingaernent Carmto do twW do uhlto Mansard or Steep Slope Fastening Pattern Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS Certificate ofAuthoriration#9503 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 4 of 8 1 TRINITY ERD 6.2.8 Minimum Nailing—Devonshire`": 1- 7" 8" 8" 8" 7" 7 aa.ea Naas M/8"exposure UAW laation y' Etposicihn de 5.518 ping Ubicad6n del sellador sw• Ten 1"Spots of Asphalt Roof Cement Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum_ Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition� Duration Designer Color Collection: 4-Nall Fastening Pattern "all Fastening Pattani su.Mrs taswrp a«.k ni su.Maeto fasM q••••bni No.Tjoca+ Mao typcai 1• +r I 1r 7• Ir NA" 6N" 41w1'6alC F1 F� F� Standard Fastening Pattern 6-Nail Fastening Pattern Fasto"for Sbpes Gnaw Than 21:12 w—M.w.Maraw.—.Wm K11W rip" +• +r +r {41a S6 r Fm.V ep.0 of Aqua ao.Mq e.Wos Mansard or Steep Slope Fastening Pattern Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-118 Certificate ofAuthorizotion#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 5 of 8 QO TRINITY ERD 6.2.1 Minimum Nailing—TruDefinition'Oakridge®,Oakridge®: 4 Nail Panan 6 Nail Pattem Empow car 4 claws Esquana tort 6 daws r r `I 1' T 12. 55/8 Expasuw fYats 66/8 Exposuw Nails Exposfddn dx 6619pWg OLS Exposidca dr 5 616pag. 6 sAr Exposuw Cum 5 5/8'Expoww Exposiddn do 5 6/8pdg. Expo4d6n de 6 6/8 pdg. Standard Fastening Pattern 6-Nail Fastening Pattern Faahning tar Slopes Grea w Than 21:12 S—ft w R —•dn RY,rip" r rr i +r 17 saw•s.se- �r Reu!t'ipeb O(A"W R-"C—n Mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing—WeatherGuard®HP: SM& 91 lAnd�w I.— r �►i Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8 Certificate ofAuthori:ation#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 6 of 8 TRINITY ' ERD 6.3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire' Hip and Ridge Shingles, High Ridge, WeatherGuard* HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using four (4) nails per shingle. Installation of DuraRidge`"° Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge: Fig.11 4 Fig.2 t'— eta��d A T.PMW MOVIM IqN- -] A M>tlls Mab 9 1' T TPP LstlYlaltl r 1 P Place A 9 I I I I I 1 I I I I I I 1 i i r r .. r I I I I I I 6.3.4 Minimum Nailing—WeatherGuardm HP Hip and Ridge: Fig.C Hip&Ridge Shingle Fastening Fig.A 9' TopVbw PPwN YAW dro[Ib \ f n A\ Kolb Iblb 1 1 T Y" A I 1 I I I 1 i i ♦ r ElPOJYR tY' I Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate of Authorization x9503 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 7 of 8 TRINITY ERD 6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles: Prevailing Standard —11, Patternng 6'Expnm 21 u• } Sealant Faxtee 7'h' 7'h• 6•Expea i Cow Expord Fastawn with Reof Ceewnt 6.3.6 Minimum Nailing—Duralkidge'" Hip&Ridge Shingles: Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. Pr.wi"wine[W d. �Tep OP Vk- Dir.ci••domimme du"m I- vim ny.rw I- Dir.men".ir,u prubrnkaks Gw ,.-- N': ....Tw • —L • OI•�aCadq llw4�iT • Oe. Qa I ILI d 1, i i sli� i • 12 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named CIA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625; (631)546-2458; Kanchi.Agrawala-Dokania@ul.com - END OF EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 6T'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 8 of 8